14
Consumer units designed for modern living THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Legrand consumer units · 2015. 10. 29. · 16075 57 With 100 A main switch and 2 x 80 A 30 mA RCD 8218 57 For 16 module unit 1 8218 58 For 22 module unit Padlock 3 4063 13 Ø 4 m

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

  • Consumer units

    designed for modern

    living

    THE GLOBAL SPECIALISTIN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

  • DESIGNis all around usModern interiors revolve around minimalist, sophisticated interior design themes consisting of clean lines, neutral tones and maximised use of space.

    Designed to blend in with the modern environment, Legrand’s new consumer units are perfectly placed to stand the test of time.

  • WWW.LEGRAND.CO.UK

    CONSUMER UNITS... DESIGN OF THE TIMES

    Legrand’s insulated and metal consumer units are

    manufactured to white RAL 9003, creating a stylish,

    understated inish which blends in perfectly with

    modern interiors.

    MEETING THE DEMANDS OF MODERN LIVING

    There is an increasing demand for additional electrical

    circuits due to the popularity of smart home solutions,

    and a growing requirement for dedicated circuits for

    items such as hard wired smoke detectors, photovoltaic

    panels and electric vehicle charging points.

    Legrand’s consumer units are available with up to 22

    ways, including a custom build option which offers

    complete choice and lexibility.

    The demands of modern

    living have led to the

    requirement for an

    increased number of

    electrical circuits

    Discreet semi-flush mounting option available Growth in requirement for dedicated circuitsIncreasing popularity of home automation and control

    3

  • design is more than

    skin deep

    With an array of design innovations making

    them easy to install, Legrand’s consumer

    units save valuable time and money during

    installation... allowing you to relect on the

    generous wiring space and the all-round

    extra protection.

    Legrand consumer units

    are itted as standard with

    80 A RCDs

    Rigid base with

    multiple cut-outs

    Removable

    pan assembly

    Rail positioned

    for maximum

    cabling space

    Removable terminal

    holders with screws in

    backed-off position

    Insulated

    shield

    Hinged door conceals

    protection devices and

    labelling

    Cut-to-length busbar

    for lexible on-site

    coniguration

    White RAL 9003

    case with high ire

    retardancy.

    Self extinguishing

    at 750°C

    4

  • WWW.LEGRAND.CO.UK

    EASY ACCESS Features include a

    removable pan assembly,

    earth terminal holder that

    simply clips into place, and

    multiple cut-outs to the

    unit’s back, bottom, top

    and sides.

    ON-SITE CONFIGURATION For lexible on-site

    coniguration, simply cut

    busbar to the required

    length.

    PROTECTION OPTIONS Legrand has everything

    you need to complete

    your installation: isolating

    switches, RCDs, NEW RX3

    MCBs and RCBOs.

    Guide to choosing the right consumer unit coniguration

    under the 17th Edition

    Dual RCD split load with dedicated main switch ways -

    Select MCBs and RCBOs to complete installation

    Dual RCD split load -

    Select MCBs to complete installation

    Main switch incomer -

    Select RCBOs to complete installation

    RCD incomer -

    Select MCBs to complete installation

    Custom build -

    Maximum lexibility

    5

  • consumer unitsinsulated and metal

    High integrity dual RCD split load with 2 unprotected ways100 A main switch and 2 x 80 A 30 mA RCD

    Dual RCD split load100 A main switch and 2 x 80 A 30 mA RCD

    Dual RCD split load -

    semi flush100 A main switch and 2 x 80 A 30 mA RCD

    Main switch incomer63 A main switch

    Main switch incomer100 A main switch

    RCD incomer80 A 30 mA RCD

    Custom build

    Insulated consumer units

    Total outgoing ways

    Conform to BS EN 60439-3. IP 30. RAL 9003. White colour. Plain door opens downwardsSupplied with neutral and earth terminals completely assembled. Supplied with 5 module spare blank plateFactory fitted link leads for both neutral and live connections. Configurable outgoing waysSelf-extinguishing at 750 °C. UL 94 V2 material for improved flame retardancy. Robust thermoplastic construction. 4 fixing holes

    Dimensions p. 11

    Metal consumer units

    Conform to BS EN 60439-3. IP 30. RAL 9003. White colour. Plain door opens downwardsSupplied with neutral and earth terminals completely assembled. Supplied with 5 module spare blank plateFactory fitted link leads for both neutral and live connections. Configurable outgoing waysPre-galvanised steel for strength and rigidity. Epoxy/polyester powder coated base and lid

    Dual RCD split load100 A main switch and 2 x 80 A 30 mA RCD

    Main switch incomer100 A main switch

    Custom build

    Total outgoing ways

    6 8 10 12 14 16 18 20 22

    – – 6065 57 – – 6065 58 – – –

    6065 59 – 6065 60 – – – – – –

    – 6065 61 – 6065 62 – 6065 50 – – 6065 51

    Dimensions p. 12

    2 4 6 8 10 12 14 16 18 20 22

    – – – – 6075 70 – – 6075 71 – – –

    – – – – 6075 57 – – 6075 58 – – –

    – – – – 8204 10 – – 8204 09 – – –

    6075 63 – – – – – – – – – –

    – – 6075 59 – 6075 60 – 6075 66 – – 6075 67 –

    – – 6075 64 – 6075 65 – – – – – –

    – 6075 68 – 6075 61 – 6075 62 – – – – –

    NEW

    6

  • 7

    6 A

    10 A

    16 A

    20 A

    25 A

    32 A

    40 A

    50 A

    63 A

    Nominal rating (In)Number of 17.5 mmmodules

    PackQty

    10 1 4022 70 4023 10 1 6064 16

    10 1 4022 71 4023 11 1 6064 17

    10 1 4022 72 4023 13 1 6064 18

    10 1 4022 73 4023 14 1 6064 19

    10 1 4022 74 4023 15 – –

    10 1 4022 75 4023 16 1 6064 20

    10 1 4022 76 4023 17 1 6064 21

    10 1 4022 77 4023 18 1 6064 28

    10 1 4022 78 4023 19 – –

    protection devicesMCBs and RCBOs

    RX3 residential MCBs - 6 kASingle pole - 230/400 V±

    RCBOs (combined MCB/RCD)Single pole and neutral - 240 V±

    B curve C curve

    30 mANumber of 17.5 mmmodules

    B curve

    RX3 MCBs - 6 kABreaking capacity : 6 kA to BS EN 60898-1

    RCBOs (combined MCB/RCD)Breaking capacity : 10 kA to BS EN 61009-1

    RCD type AC conform toBS EN 61009-1

    Terminal capacity : rigid conductor 35 mm2

    flexible conductor 25 mm2

    6064 184022 70

  • 8

    insulated consumer unitssurface mounting

    Accessories for surface mounting units

    Lockable brackets

    1 8218 57 For 16 module unit 1 8218 58 For 22 module unit

    Padlock

    3 4063 13 Ø 4 m

    Conform to BS EN 60439-3. IP 30. RAL 9003 - white colourSelf-extinguishing at 750 °C - UL 94 V2 material for improved flame retardancyRobust, rigid thermoplastic construction with 4 fixing holesDoor opens downwardsSupplied with neutral and earth terminals completely assembledSupplied with 5 module spare blank plate (except 4 module unit)MCBs to be ordered separately, (see p. 10)Rigid base with multiple cut-outsRemovable terminal holders with screws in backed-off positionInsulated shieldCut-to-length busbarRemovable pan assembly

    6075 63 6075 646075 57

    Pack Cat. Nos. Insulated high integrity dual RCD split load with 2 unprotected ways - surface mounting

    16 module unit (8 + 2 ways available)

    1 6075 70 With 100 A main switch and 2 x 80 A 30 mA RCD

    22 module unit (13 + 3 ways available)

    1 6075 71 With 100 A main switch and 2 x 80 A 30 mA RCD

    Pack Cat. Nos. Insulated custom build - surface mounting

    Allow several configurations when using kits and incomers (isolating switches, RCDs, RCBOs)

    For kits, (see p. 215) For incomers and outgoing devices, (see p. 10)

    1 6075 68 4 modules available

    1 6075 61 8 modules available

    1 6075 62 12 modules available

    6075 71

    Dimensions p.11

    RX3 residential MCBs and single module RCBOs p. 10

    New

    image

    VC to

    supply

    NEW

    Insulated dual RCD split load - surface mounting

    16 module unit (10 ways available)

    1 6075 57 With 100 A main switch and 2 x 80 A 30 mA RCD

    22 module unit (16 ways available)

    1 6075 58 With 100 A main switch and 2 x 80 A 30 mA RCD

    NEW

    NEW

    Insulated with incomer - surface mounting

    4 module unit

    1 6075 63 With 63 A main switch (2 ways available)

    8 module unit

    1 6075 59 With 100 A main switch (6 ways available) 1 6075 64 With 80 A 30 mA RCD (6 ways available)

    12 module unit

    1 6075 60 With 100 A main switch (10 ways available) 1 6075 65 With 80 A 30 mA RCD (10 ways available)

    16 module unit

    1 6075 66 With 100 A main switch (14 ways available)

    22 module unit

    1 6075 67 With 100 A main switch (20 ways available)

    NEW

    Accessories for semi-flush mounting units

    Lockable brackets

    1 8204 71 For 16 module unit 1 8204 72 For 22 module unit

    Padlock

    3 4063 13 Ø 4 m

    Insulated dual RCD split load - semi-flush mounting

    16 module unit (10 ways available)

    1 8204 10 With 100 A main switch and 2 x 80 A 30 mA RCD

    22 module unit (16 ways available)

    1 8204 09 With 100 A main switch and 2 x 80 A 30 mA RCD

    NEW

    NEW

  • 9

    Pack Cat. Nos. Accessories

    Incomer or dual tariff kit

    1 6075 19 Comprises : 1 flexible neutral (blue) lead 1 rigid neutral link

    Split load kit

    1 6075 39 Comprises : 1 flexible live (brown) lead 1 flexible neutral (blue) lead 2 rigid neutral links

    Split load dual tariff kit (for insulated units only)

    1 6075 49 Comprises : 1 flexible live (brown) lead 2 flexible neutral (blue) leads 2 rigid neutral links 1 neutral terminal

    Spare blank plate RAL 9003

    20 0016 60 5 modules - white colour

    Spare blank plate RAL 9010

    10 0016 64 18 module, separable by single or half modules

    Spare busbar

    5 6075 99 21 prongs

    Spacing elements

    10 4063 07 0·5 module

    Locking device for MCBs and RCDs

    2 4063 03 Locking attachment for Ø 4 mm and Ø 6 mm padlocks

    Padlock for MCBs and RCDs

    3 4063 13 Padlock Ø 4 m

    Spare terminal block

    1 8204 07 13 hole

    Self-adhesive label holder

    10 0049 96 Width : 16 mm Width available for marking : 12 mm Length 530 mm (24 modules)

    Metal custom build - surface mounting

    Epoxy/polyester powder coated base and lid Stand-off feet complete with keyhole fixing Allow several configurations when using kits and

    incomers (isolating switches, RCDs, RCBOs) For kits, (see opposite) For incomers and outgoing devices, (see p. 10)

    1 6065 61 8 modules available

    1 6065 62 12 modules available

    1 6065 50 16 modules available

    1 6065 51 22 modules available

    Metal with incomer - surface mounting

    Epoxy/polyester powder coated base and lid Stand-off feet complete with keyhole fixing

    8 module unit

    1 6065 59 With 100 A main switch (6 ways available)

    12 module unit

    1 6065 60 With 100 A main switch (10 ways available)

    metal consumer unitssurface mounting

    accessoriesfor insulated and metal consumer units

    Conform to BS EN 60439-3. IP 30. RAL 9003 - white colourPre-galvanised steel for strength and rigidityDoor opens downwardsSupplied with neutral and earth terminals completely assembledSupplied with 5 module spare blank plateMCBs to be ordered separately, (see p. 10)

    6065 62

    0049 96

    Pack Cat. Nos. Metal dual RCD split load - surface mounting

    16 module unit (10 ways available)

    1 6065 57 With 100 A main switch and 2 x 80 A 30 mA RCD

    22 module unit (16 ways available)

    1 6065 58 With 100 A main switch and 2 x 80 A 30 mA RCD

    Dimensions p. 12

    RX3 residential MCBs and single module RCBOs p. 10

    NEW

    NEW

    Available May

    2013

    NEW

    NEW

  • protection and control devices

    Pack Cat. Nos. RX3 residential MCBs - 6 kA

    Breaking capacity : 6 kA to BS EN 60898-1 Single pole - 230/400 V± B curve C curve Nominal rating Number of (In) 17·5 mm modules

    10 4022 70 4023 10 6 A 1 10 4022 71 4023 11 10 A 1 10 4022 72 4023 13 16 A 1 10 4022 73 4023 14 20 A 1 10 4022 74 4023 15 25 A 1 10 4022 75 4023 16 32 A 1 10 4022 76 4023 17 40 A 1 10 4022 77 4023 18 50 A 1 10 4022 78 4023 19 63 A 1

    DX3 multi-purpose MCBs - 10 kA

    Breaking capacity : 10 kA to BS EN 60947-2 Single pole - 230/400 V± B C B curve C curve Nominal rating Number of (In) 17·5 mm modules

    1 1 4074 29 4076 66 6 A 1 1 10 4074 30 4076 68 10 A 1 1 10 4074 32 4076 70 16 A 1 1 1 4074 33 4076 71 20 A 1 1 1 4074 35 4076 73 32 A 1 1 1 4074 36 4076 74 40 A 1 1 1 4074 37 4076 75 50 A 1 1 1 4074 38 4076 76 63 A 1

    4064 554020 27 4125 44 4130 91

    Pack Cat. Nos. RX3 residual current devices (RCDs)

    Conform to BS EN 61008-1 Terminal capacity : rigid conductor 35 mm2 flexible conductor 25 mm2

    Double pole 230 V± Type AC Nominal rating Number of (In) 17·5 mm modules

    30 mA

    1 4020 24 25 A 2 1 4020 25 40 A 2 1 4020 26 63 A 2 1 4020 27 80 A 2

    100 mA

    1 4020 28 25 A 2 1 4020 29 40 A 2 1 4020 30 63 A 2

    DX3 Isolating switches

    Conform to BS EN 60947-3, IEC 60669-1 Usage : AC 22 according to IEC 60947-3 Red handle Double break contacts, padlockable 50 mm2 capacity shielded terminals

    Number of

    17·5 mm modules

    5 4064 53 63 A double pole 2 5 4064 55 100 A double pole 2

    CX3 Contactor with 230 V± coil

    Conforms to BS EN 61095

    Double pole (L + N) 250 V± 230 V± coil circuit

    Type of Number of I max. contact 17·5 mm modules

    1 4125 44 25 A 2 N/O 1

    For other contactors, see current Industrial and Power Protection catalogue

    230 V

    6064 18

    RCBOs (combined MCB/RCD) - Single module

    Breaking capacity : 10 kA to BS EN 61009-1 RCD type AC conform to BS EN 61009-1

    Terminal capacity : rigid conductor 35 mm2 flexible conductor 25 mm2

    Single pole and neutral - 240 V± B curve Nominal rating Number of (In) 17·5 mm modules 30 mA 1 6064 16 6 A 1 1 6064 17 10 A 1 1 6064 18 16 A 1 1 6064 19 20 A 1 1 6064 20 32 A 1 1 6064 21 40 A 1 1 6064 28 50 A 1

    Bell transformers

    d Conform to IEC/EN 61558-2-8 Supplied with label holder Protected against overloads and short circuits Power to 8 V-12 V or 24 V access control devices

    such as bells and chimes Possibility for supply busbars to run through (Cat. Nos. 4130 90/91)

    Number

    Secondary (V) Rating (A) Power (VA) of 17·5 mm

    modules 230 V / 8 V

    1 4130 90 8 V± 0·5 A 4 VA 2

    230 V / 12 V - 8 V

    1 4130 91 12/8 V± 0·66/1 A 8 VA 2

    230 V / 24 V - 12 V

    1 4130 93 24/12 V± 1/1·5 A 24/18 VA 4

    NEW

    4022 70

    NEW

    NEW

    NEW

    NEW

    10

  • insulated consumer unitssurface mounting

    B

    A 110

    50

    195

    40 50

    20

    90

    4 cut-outs

    20 x 25

    1 cut-out

    40 x 50

    1 cut-out

    50 x 50

    4 cut-outs 20 x 25

    225

    114

    4 cut-outs

    25 x 25

    2 cut-outs

    20 x 25

    n Insulated - surface mounting dimensions (mm)

    n 4 module unitBack box fixing centres and cable entries (mm)

    225

    114

    162

    6 cut-outs

    20 x 25 8 cut-outs

    25 x 25

    6 cut-outs 20 x 25

    2 cut-outs

    50 x 50

    2 cut-outs

    40 x 50

    40 50

    20

    2 cut-outs

    20 x 25

    n 8 module unitBack box fixing centres and cable entries (mm)

    225

    180

    268

    2 cut-outs

    50 x 50

    2 cut-outs

    40 x 50

    40 50

    20

    6 cut-outs

    20 x 25

    2 cut-outs

    20 x 18.5

    2 cut-outs 20 x 18.5

    22 cut-outs

    25 x 20

    2 cut-outs 20 x 25

    2 cut-outs

    20 x 25

    n 12 module unitBack box fixing centres and cable entries (mm)

    Modules A (mm) B (mm)

    4 140 225

    8 212 225

    12 298 225

    14/16 370 225

    20/22 478 225

    View fromsides

    View frombelow

    View fromabove

    View fromsides

    View frombelow

    View fromabove

    View fromsides

    View frombelow

    View fromabove

    11

  • 12

    insulated consumer unitssurface mounting (continued)

    40 50

    20

    10 cut-outs 20 x 25

    2 cut-outs 50 x 50 2 cut-outs 40 x 50

    30 cut-outs 25 x 20

    22

    5

    18

    0

    340

    8 cut-outs 20 x 25

    2 cut-outs

    20 x 25

    n 14/16 module unitBack box fixing centres and cable entries (mm)

    n 20/22 module unitBack box fixing centres and cable entries (mm)

    View fromsides

    View frombelow

    View fromabove

    10 cut-outs 20 x 252 cut-outs 20 x 22

    2 cut-outs 20 x 22 12 cut-outs 20 x 25

    42 cut-outs 25 x 20

    22

    5

    18

    0

    448

    2 cut-outs

    20 x 25

    40 50

    20

    2 cut-outs 50 x 50 2 cut-outs 40 x 50

    View fromsides

    View frombelow

    View fromabove

    metal consumer unitssurface mounting

    B

    A 113

    50

    200

    4 cut-outs Ø 32

    1 cut-out Ø 25

    Ø 5

    Ø 9

    1 obround

    cut-out 100 x 50

    4

    3

    95

    80

    100

    n Metal - surface mounting dimensions (mm)

    n 8 module unitBack box fixing centres and cable entries (mm)

    Modules A (mm) B (mm)

    8 219 235

    12 305 235

    16 377 235

    22 485 235

    View frombelow

    View fromabove

  • 4 cut-outs Ø 20

    4 cut-outs Ø 324 cut-outs Ø 25

    2 obround

    cut-outs 100 x 50

    95

    80

    250

    120

    175

    n 16 module unitBack box fixing centres and cable entries (mm)

    4 cut-outs Ø 25

    4 cut-outs Ø 328 cut-outs Ø 20

    2 obround

    cut-outs 100 x 50

    95

    80

    350

    120

    275

    n 22 module unitBack box fixing centres and cable entries (mm)

    View frombelow

    View fromabove

    View frombelow

    View fromabove

    metal consumer unitssurface mounting (continued)

    4 cut-outs Ø 32

    2 cut-outs Ø 252 cut-outs Ø 20

    1 obround

    cut-out 100 x 50

    95

    80

    175

    100

    n 12 module unitBack box fixing centres and cable entries (mm)

    View frombelow

    View fromabove

    13

  • Co

    nsu

    me

    r u

    nit

    pro

    du

    ct g

    uid

    e 0

    4/2

    01

    3.P

    DFHead ofice (UK and Ireland):

    Legrand Electric LimitedGreat King Street North, Birmingham, B19 2LFTel: 0870 608 9000 Fax: 0870 608 9004Website: www.legrand.co.uk

    The Legrand logo is a registered trademark of the Legrand group of companies.

    Distributor:

    This document is printed on sustainably sourced paper. Please recycle.

    Contact details United Kingdom

    Great King Street North, Birmingham, B19 2LF

    Customer Services: Tel: +44 (0) 845 605 4333 Fax: +44 (0) 845 605 4334E-mail: [email protected]

    Quotations and Technical Support: Tel: +44 (0) 870 608 9020 Fax: +44 (0) 870 608 9021E-mail: [email protected]

    Republic of Ireland: Tel: 01 295 9673 Fax: 01 295 4671E-mail: [email protected]