Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
Consumer units
designed for modern
living
THE GLOBAL SPECIALISTIN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
DESIGNis all around usModern interiors revolve around minimalist, sophisticated interior design themes consisting of clean lines, neutral tones and maximised use of space.
Designed to blend in with the modern environment, Legrand’s new consumer units are perfectly placed to stand the test of time.
WWW.LEGRAND.CO.UK
CONSUMER UNITS... DESIGN OF THE TIMES
Legrand’s insulated and metal consumer units are
manufactured to white RAL 9003, creating a stylish,
understated inish which blends in perfectly with
modern interiors.
MEETING THE DEMANDS OF MODERN LIVING
There is an increasing demand for additional electrical
circuits due to the popularity of smart home solutions,
and a growing requirement for dedicated circuits for
items such as hard wired smoke detectors, photovoltaic
panels and electric vehicle charging points.
Legrand’s consumer units are available with up to 22
ways, including a custom build option which offers
complete choice and lexibility.
The demands of modern
living have led to the
requirement for an
increased number of
electrical circuits
Discreet semi-flush mounting option available Growth in requirement for dedicated circuitsIncreasing popularity of home automation and control
3
design is more than
skin deep
With an array of design innovations making
them easy to install, Legrand’s consumer
units save valuable time and money during
installation... allowing you to relect on the
generous wiring space and the all-round
extra protection.
Legrand consumer units
are itted as standard with
80 A RCDs
Rigid base with
multiple cut-outs
Removable
pan assembly
Rail positioned
for maximum
cabling space
Removable terminal
holders with screws in
backed-off position
Insulated
shield
Hinged door conceals
protection devices and
labelling
Cut-to-length busbar
for lexible on-site
coniguration
White RAL 9003
case with high ire
retardancy.
Self extinguishing
at 750°C
4
WWW.LEGRAND.CO.UK
EASY ACCESS Features include a
removable pan assembly,
earth terminal holder that
simply clips into place, and
multiple cut-outs to the
unit’s back, bottom, top
and sides.
ON-SITE CONFIGURATION For lexible on-site
coniguration, simply cut
busbar to the required
length.
PROTECTION OPTIONS Legrand has everything
you need to complete
your installation: isolating
switches, RCDs, NEW RX3
MCBs and RCBOs.
Guide to choosing the right consumer unit coniguration
under the 17th Edition
Dual RCD split load with dedicated main switch ways -
Select MCBs and RCBOs to complete installation
Dual RCD split load -
Select MCBs to complete installation
Main switch incomer -
Select RCBOs to complete installation
RCD incomer -
Select MCBs to complete installation
Custom build -
Maximum lexibility
5
consumer unitsinsulated and metal
High integrity dual RCD split load with 2 unprotected ways100 A main switch and 2 x 80 A 30 mA RCD
Dual RCD split load100 A main switch and 2 x 80 A 30 mA RCD
Dual RCD split load -
semi flush100 A main switch and 2 x 80 A 30 mA RCD
Main switch incomer63 A main switch
Main switch incomer100 A main switch
RCD incomer80 A 30 mA RCD
Custom build
Insulated consumer units
Total outgoing ways
Conform to BS EN 60439-3. IP 30. RAL 9003. White colour. Plain door opens downwardsSupplied with neutral and earth terminals completely assembled. Supplied with 5 module spare blank plateFactory fitted link leads for both neutral and live connections. Configurable outgoing waysSelf-extinguishing at 750 °C. UL 94 V2 material for improved flame retardancy. Robust thermoplastic construction. 4 fixing holes
Dimensions p. 11
Metal consumer units
Conform to BS EN 60439-3. IP 30. RAL 9003. White colour. Plain door opens downwardsSupplied with neutral and earth terminals completely assembled. Supplied with 5 module spare blank plateFactory fitted link leads for both neutral and live connections. Configurable outgoing waysPre-galvanised steel for strength and rigidity. Epoxy/polyester powder coated base and lid
Dual RCD split load100 A main switch and 2 x 80 A 30 mA RCD
Main switch incomer100 A main switch
Custom build
Total outgoing ways
6 8 10 12 14 16 18 20 22
– – 6065 57 – – 6065 58 – – –
6065 59 – 6065 60 – – – – – –
– 6065 61 – 6065 62 – 6065 50 – – 6065 51
Dimensions p. 12
2 4 6 8 10 12 14 16 18 20 22
– – – – 6075 70 – – 6075 71 – – –
– – – – 6075 57 – – 6075 58 – – –
– – – – 8204 10 – – 8204 09 – – –
6075 63 – – – – – – – – – –
– – 6075 59 – 6075 60 – 6075 66 – – 6075 67 –
– – 6075 64 – 6075 65 – – – – – –
– 6075 68 – 6075 61 – 6075 62 – – – – –
NEW
6
7
6 A
10 A
16 A
20 A
25 A
32 A
40 A
50 A
63 A
Nominal rating (In)Number of 17.5 mmmodules
PackQty
10 1 4022 70 4023 10 1 6064 16
10 1 4022 71 4023 11 1 6064 17
10 1 4022 72 4023 13 1 6064 18
10 1 4022 73 4023 14 1 6064 19
10 1 4022 74 4023 15 – –
10 1 4022 75 4023 16 1 6064 20
10 1 4022 76 4023 17 1 6064 21
10 1 4022 77 4023 18 1 6064 28
10 1 4022 78 4023 19 – –
protection devicesMCBs and RCBOs
RX3 residential MCBs - 6 kASingle pole - 230/400 V±
RCBOs (combined MCB/RCD)Single pole and neutral - 240 V±
B curve C curve
30 mANumber of 17.5 mmmodules
B curve
RX3 MCBs - 6 kABreaking capacity : 6 kA to BS EN 60898-1
RCBOs (combined MCB/RCD)Breaking capacity : 10 kA to BS EN 61009-1
RCD type AC conform toBS EN 61009-1
Terminal capacity : rigid conductor 35 mm2
flexible conductor 25 mm2
6064 184022 70
8
insulated consumer unitssurface mounting
Accessories for surface mounting units
Lockable brackets
1 8218 57 For 16 module unit 1 8218 58 For 22 module unit
Padlock
3 4063 13 Ø 4 m
Conform to BS EN 60439-3. IP 30. RAL 9003 - white colourSelf-extinguishing at 750 °C - UL 94 V2 material for improved flame retardancyRobust, rigid thermoplastic construction with 4 fixing holesDoor opens downwardsSupplied with neutral and earth terminals completely assembledSupplied with 5 module spare blank plate (except 4 module unit)MCBs to be ordered separately, (see p. 10)Rigid base with multiple cut-outsRemovable terminal holders with screws in backed-off positionInsulated shieldCut-to-length busbarRemovable pan assembly
6075 63 6075 646075 57
Pack Cat. Nos. Insulated high integrity dual RCD split load with 2 unprotected ways - surface mounting
16 module unit (8 + 2 ways available)
1 6075 70 With 100 A main switch and 2 x 80 A 30 mA RCD
22 module unit (13 + 3 ways available)
1 6075 71 With 100 A main switch and 2 x 80 A 30 mA RCD
Pack Cat. Nos. Insulated custom build - surface mounting
Allow several configurations when using kits and incomers (isolating switches, RCDs, RCBOs)
For kits, (see p. 215) For incomers and outgoing devices, (see p. 10)
1 6075 68 4 modules available
1 6075 61 8 modules available
1 6075 62 12 modules available
6075 71
Dimensions p.11
RX3 residential MCBs and single module RCBOs p. 10
New
image
VC to
supply
NEW
Insulated dual RCD split load - surface mounting
16 module unit (10 ways available)
1 6075 57 With 100 A main switch and 2 x 80 A 30 mA RCD
22 module unit (16 ways available)
1 6075 58 With 100 A main switch and 2 x 80 A 30 mA RCD
NEW
NEW
Insulated with incomer - surface mounting
4 module unit
1 6075 63 With 63 A main switch (2 ways available)
8 module unit
1 6075 59 With 100 A main switch (6 ways available) 1 6075 64 With 80 A 30 mA RCD (6 ways available)
12 module unit
1 6075 60 With 100 A main switch (10 ways available) 1 6075 65 With 80 A 30 mA RCD (10 ways available)
16 module unit
1 6075 66 With 100 A main switch (14 ways available)
22 module unit
1 6075 67 With 100 A main switch (20 ways available)
NEW
Accessories for semi-flush mounting units
Lockable brackets
1 8204 71 For 16 module unit 1 8204 72 For 22 module unit
Padlock
3 4063 13 Ø 4 m
Insulated dual RCD split load - semi-flush mounting
16 module unit (10 ways available)
1 8204 10 With 100 A main switch and 2 x 80 A 30 mA RCD
22 module unit (16 ways available)
1 8204 09 With 100 A main switch and 2 x 80 A 30 mA RCD
NEW
NEW
9
Pack Cat. Nos. Accessories
Incomer or dual tariff kit
1 6075 19 Comprises : 1 flexible neutral (blue) lead 1 rigid neutral link
Split load kit
1 6075 39 Comprises : 1 flexible live (brown) lead 1 flexible neutral (blue) lead 2 rigid neutral links
Split load dual tariff kit (for insulated units only)
1 6075 49 Comprises : 1 flexible live (brown) lead 2 flexible neutral (blue) leads 2 rigid neutral links 1 neutral terminal
Spare blank plate RAL 9003
20 0016 60 5 modules - white colour
Spare blank plate RAL 9010
10 0016 64 18 module, separable by single or half modules
Spare busbar
5 6075 99 21 prongs
Spacing elements
10 4063 07 0·5 module
Locking device for MCBs and RCDs
2 4063 03 Locking attachment for Ø 4 mm and Ø 6 mm padlocks
Padlock for MCBs and RCDs
3 4063 13 Padlock Ø 4 m
Spare terminal block
1 8204 07 13 hole
Self-adhesive label holder
10 0049 96 Width : 16 mm Width available for marking : 12 mm Length 530 mm (24 modules)
Metal custom build - surface mounting
Epoxy/polyester powder coated base and lid Stand-off feet complete with keyhole fixing Allow several configurations when using kits and
incomers (isolating switches, RCDs, RCBOs) For kits, (see opposite) For incomers and outgoing devices, (see p. 10)
1 6065 61 8 modules available
1 6065 62 12 modules available
1 6065 50 16 modules available
1 6065 51 22 modules available
Metal with incomer - surface mounting
Epoxy/polyester powder coated base and lid Stand-off feet complete with keyhole fixing
8 module unit
1 6065 59 With 100 A main switch (6 ways available)
12 module unit
1 6065 60 With 100 A main switch (10 ways available)
metal consumer unitssurface mounting
accessoriesfor insulated and metal consumer units
Conform to BS EN 60439-3. IP 30. RAL 9003 - white colourPre-galvanised steel for strength and rigidityDoor opens downwardsSupplied with neutral and earth terminals completely assembledSupplied with 5 module spare blank plateMCBs to be ordered separately, (see p. 10)
6065 62
0049 96
Pack Cat. Nos. Metal dual RCD split load - surface mounting
16 module unit (10 ways available)
1 6065 57 With 100 A main switch and 2 x 80 A 30 mA RCD
22 module unit (16 ways available)
1 6065 58 With 100 A main switch and 2 x 80 A 30 mA RCD
Dimensions p. 12
RX3 residential MCBs and single module RCBOs p. 10
NEW
NEW
Available May
2013
NEW
NEW
protection and control devices
Pack Cat. Nos. RX3 residential MCBs - 6 kA
Breaking capacity : 6 kA to BS EN 60898-1 Single pole - 230/400 V± B curve C curve Nominal rating Number of (In) 17·5 mm modules
10 4022 70 4023 10 6 A 1 10 4022 71 4023 11 10 A 1 10 4022 72 4023 13 16 A 1 10 4022 73 4023 14 20 A 1 10 4022 74 4023 15 25 A 1 10 4022 75 4023 16 32 A 1 10 4022 76 4023 17 40 A 1 10 4022 77 4023 18 50 A 1 10 4022 78 4023 19 63 A 1
DX3 multi-purpose MCBs - 10 kA
Breaking capacity : 10 kA to BS EN 60947-2 Single pole - 230/400 V± B C B curve C curve Nominal rating Number of (In) 17·5 mm modules
1 1 4074 29 4076 66 6 A 1 1 10 4074 30 4076 68 10 A 1 1 10 4074 32 4076 70 16 A 1 1 1 4074 33 4076 71 20 A 1 1 1 4074 35 4076 73 32 A 1 1 1 4074 36 4076 74 40 A 1 1 1 4074 37 4076 75 50 A 1 1 1 4074 38 4076 76 63 A 1
4064 554020 27 4125 44 4130 91
Pack Cat. Nos. RX3 residual current devices (RCDs)
Conform to BS EN 61008-1 Terminal capacity : rigid conductor 35 mm2 flexible conductor 25 mm2
Double pole 230 V± Type AC Nominal rating Number of (In) 17·5 mm modules
30 mA
1 4020 24 25 A 2 1 4020 25 40 A 2 1 4020 26 63 A 2 1 4020 27 80 A 2
100 mA
1 4020 28 25 A 2 1 4020 29 40 A 2 1 4020 30 63 A 2
DX3 Isolating switches
Conform to BS EN 60947-3, IEC 60669-1 Usage : AC 22 according to IEC 60947-3 Red handle Double break contacts, padlockable 50 mm2 capacity shielded terminals
Number of
17·5 mm modules
5 4064 53 63 A double pole 2 5 4064 55 100 A double pole 2
CX3 Contactor with 230 V± coil
Conforms to BS EN 61095
Double pole (L + N) 250 V± 230 V± coil circuit
Type of Number of I max. contact 17·5 mm modules
1 4125 44 25 A 2 N/O 1
For other contactors, see current Industrial and Power Protection catalogue
230 V
6064 18
RCBOs (combined MCB/RCD) - Single module
Breaking capacity : 10 kA to BS EN 61009-1 RCD type AC conform to BS EN 61009-1
Terminal capacity : rigid conductor 35 mm2 flexible conductor 25 mm2
Single pole and neutral - 240 V± B curve Nominal rating Number of (In) 17·5 mm modules 30 mA 1 6064 16 6 A 1 1 6064 17 10 A 1 1 6064 18 16 A 1 1 6064 19 20 A 1 1 6064 20 32 A 1 1 6064 21 40 A 1 1 6064 28 50 A 1
Bell transformers
d Conform to IEC/EN 61558-2-8 Supplied with label holder Protected against overloads and short circuits Power to 8 V-12 V or 24 V access control devices
such as bells and chimes Possibility for supply busbars to run through (Cat. Nos. 4130 90/91)
Number
Secondary (V) Rating (A) Power (VA) of 17·5 mm
modules 230 V / 8 V
1 4130 90 8 V± 0·5 A 4 VA 2
230 V / 12 V - 8 V
1 4130 91 12/8 V± 0·66/1 A 8 VA 2
230 V / 24 V - 12 V
1 4130 93 24/12 V± 1/1·5 A 24/18 VA 4
NEW
4022 70
NEW
NEW
NEW
NEW
10
insulated consumer unitssurface mounting
B
A 110
50
195
40 50
20
90
4 cut-outs
20 x 25
1 cut-out
40 x 50
1 cut-out
50 x 50
4 cut-outs 20 x 25
225
114
4 cut-outs
25 x 25
2 cut-outs
20 x 25
n Insulated - surface mounting dimensions (mm)
n 4 module unitBack box fixing centres and cable entries (mm)
225
114
162
6 cut-outs
20 x 25 8 cut-outs
25 x 25
6 cut-outs 20 x 25
2 cut-outs
50 x 50
2 cut-outs
40 x 50
40 50
20
2 cut-outs
20 x 25
n 8 module unitBack box fixing centres and cable entries (mm)
225
180
268
2 cut-outs
50 x 50
2 cut-outs
40 x 50
40 50
20
6 cut-outs
20 x 25
2 cut-outs
20 x 18.5
2 cut-outs 20 x 18.5
22 cut-outs
25 x 20
2 cut-outs 20 x 25
2 cut-outs
20 x 25
n 12 module unitBack box fixing centres and cable entries (mm)
Modules A (mm) B (mm)
4 140 225
8 212 225
12 298 225
14/16 370 225
20/22 478 225
View fromsides
View frombelow
View fromabove
View fromsides
View frombelow
View fromabove
View fromsides
View frombelow
View fromabove
11
12
insulated consumer unitssurface mounting (continued)
40 50
20
10 cut-outs 20 x 25
2 cut-outs 50 x 50 2 cut-outs 40 x 50
30 cut-outs 25 x 20
22
5
18
0
340
8 cut-outs 20 x 25
2 cut-outs
20 x 25
n 14/16 module unitBack box fixing centres and cable entries (mm)
n 20/22 module unitBack box fixing centres and cable entries (mm)
View fromsides
View frombelow
View fromabove
10 cut-outs 20 x 252 cut-outs 20 x 22
2 cut-outs 20 x 22 12 cut-outs 20 x 25
42 cut-outs 25 x 20
22
5
18
0
448
2 cut-outs
20 x 25
40 50
20
2 cut-outs 50 x 50 2 cut-outs 40 x 50
View fromsides
View frombelow
View fromabove
metal consumer unitssurface mounting
B
A 113
50
200
4 cut-outs Ø 32
1 cut-out Ø 25
Ø 5
Ø 9
1 obround
cut-out 100 x 50
4
3
95
80
100
n Metal - surface mounting dimensions (mm)
n 8 module unitBack box fixing centres and cable entries (mm)
Modules A (mm) B (mm)
8 219 235
12 305 235
16 377 235
22 485 235
View frombelow
View fromabove
4 cut-outs Ø 20
4 cut-outs Ø 324 cut-outs Ø 25
2 obround
cut-outs 100 x 50
95
80
250
120
175
n 16 module unitBack box fixing centres and cable entries (mm)
4 cut-outs Ø 25
4 cut-outs Ø 328 cut-outs Ø 20
2 obround
cut-outs 100 x 50
95
80
350
120
275
n 22 module unitBack box fixing centres and cable entries (mm)
View frombelow
View fromabove
View frombelow
View fromabove
metal consumer unitssurface mounting (continued)
4 cut-outs Ø 32
2 cut-outs Ø 252 cut-outs Ø 20
1 obround
cut-out 100 x 50
95
80
175
100
n 12 module unitBack box fixing centres and cable entries (mm)
View frombelow
View fromabove
13
Co
nsu
me
r u
nit
pro
du
ct g
uid
e 0
4/2
01
3.P
DFHead ofice (UK and Ireland):
Legrand Electric LimitedGreat King Street North, Birmingham, B19 2LFTel: 0870 608 9000 Fax: 0870 608 9004Website: www.legrand.co.uk
The Legrand logo is a registered trademark of the Legrand group of companies.
Distributor:
This document is printed on sustainably sourced paper. Please recycle.
Contact details United Kingdom
Great King Street North, Birmingham, B19 2LF
Customer Services: Tel: +44 (0) 845 605 4333 Fax: +44 (0) 845 605 4334E-mail: [email protected]
Quotations and Technical Support: Tel: +44 (0) 870 608 9020 Fax: +44 (0) 870 608 9021E-mail: [email protected]
Republic of Ireland: Tel: 01 295 9673 Fax: 01 295 4671E-mail: [email protected]