12
1 LAST RESULTS OF THE BERKELEY-SACLAY-ORSAY TPC COSMIC-RAY TESTS P. Colas , C. Coquelet, E.Delagnes, A.Giganon, Y.Giomataris , J.-P. Robert, DAPNIA-CEA Saclay F. Bieser, M.Ronan LBNL Berkeley R. Cizeron, G. Guilhem, V.Lepeltier LAL Orsay K. Sachs, Carleton University Ottawa, Ph. Rosier, J. Pouthas, T.Zerguerras , IPN Orsay Vincent Lepeltier ILCD Collaboration meeting January 14th 2005

L A ST RESULTS OF THE BERKELEY-SACLAY-ORSAY TPC COSMIC-RAY TESTS

Embed Size (px)

DESCRIPTION

L A ST RESULTS OF THE BERKELEY-SACLAY-ORSAY TPC COSMIC-RAY TESTS. P. Colas , C. Coquelet, E.Delagnes, A.Giganon, Y.Giomataris , J.-P. Robert, DAPNIA-CEA Saclay F. Bieser, M.Ronan LBNL Berkeley R. Cizeron, G. Guilhem, V.Lepeltier L AL Orsay K. Sachs, Carleton University Ottawa, - PowerPoint PPT Presentation

Citation preview

Page 1: L A ST RESULTS OF THE BERKELEY-SACLAY-ORSAY TPC COSMIC-RAY TESTS

1

LAST RESULTS OF THE BERKELEY-SACLAY-ORSAY TPC COSMIC-RAY TESTS

P. Colas, C. Coquelet, E.Delagnes, A.Giganon, Y.Giomataris, J.-P. Robert, DAPNIA-CEA Saclay F. Bieser, M.Ronan LBNL Berkeley

R. Cizeron, G. Guilhem, V.Lepeltier LAL Orsay

K. Sachs, Carleton University Ottawa,

Ph. Rosier, J. Pouthas, T.Zerguerras, IPN Orsay

Vincent Lepeltier ILCD Collaboration meeting January 14th 2005

Page 2: L A ST RESULTS OF THE BERKELEY-SACLAY-ORSAY TPC COSMIC-RAY TESTS

2

chamber diameter 50 cm length 50 cm

Berkeley Saclay Orsay

mesh

50 m pitch

50 m gap

readout anode pad plane

1024 pads

2x10 mm2pads

CHAMBER DESIGN AND PAD LAYOUT

1x10 mm2pads

Vincent Lepeltier ILCD Collaboration meeting January 14th 2005

Page 3: L A ST RESULTS OF THE BERKELEY-SACLAY-ORSAY TPC COSMIC-RAY TESTS

3

new data acquisition in April-May 2004:

superconducting magnet runs at 0.1, 0.3, 0.5, 0.7, 1, 1.5 & 2 Tesla

trigger: 2-3 fold scintillator10 – 50 % efficiency (lower at high fields)

gases: Ar + CF4 / CH4/ iso-C4H10

10% 3% 5%

data acquisition: X20

2004 COSMIC RAY RUN

online event display

Vincent Lepeltier ILCD Collaboration meeting January 14th 2005

Page 4: L A ST RESULTS OF THE BERKELEY-SACLAY-ORSAY TPC COSMIC-RAY TESTS

4

GOOD NEWS GOOD NEWS

0

100

200

300

400

500

600

0 0,5 1 1,5 2

Ar CF4

Ar Iso

Ar CH4

Magnetic field (T)

Ave

rage

am

plit

ude

sum

after investigation…

it was due to an error in the analysis !!!

no effect of B on the amplitude!

wrong!!!

Vincent Lepeltier ILCD Collaboration meeting January 14th 2005

Page 5: L A ST RESULTS OF THE BERKELEY-SACLAY-ORSAY TPC COSMIC-RAY TESTS

5

dE/dX vs particle momentum10 cm Ar-

5%isobutane

momentum distribution

Vincent Lepeltier ILCD Collaboration meeting January 14th 2005

relativistic rise clearly visible

Page 6: L A ST RESULTS OF THE BERKELEY-SACLAY-ORSAY TPC COSMIC-RAY TESTS

6

effect of the transverse diffusion

z= 45cmz= 39cmz= 33cm

z= 25cmz= 18cmz= 12cm

P10 gas@ 0.5T

Vincent Lepeltier ILCD Collaboration meeting January 14th 2005

σ2 (width) increasing with drift distance

Page 7: L A ST RESULTS OF THE BERKELEY-SACLAY-ORSAY TPC COSMIC-RAY TESTS

7

track width vs zP10 [email protected]

Vincent Lepeltier ILCD Collaboration meeting January 14th 2005

Page 8: L A ST RESULTS OF THE BERKELEY-SACLAY-ORSAY TPC COSMIC-RAY TESTS

8

track width vs zAr-3%CF4 gas

Vincent Lepeltier ILCD Collaboration meeting January 14th 2005

Page 9: L A ST RESULTS OF THE BERKELEY-SACLAY-ORSAY TPC COSMIC-RAY TESTS

9

Ar+3% CF4 results

track width vs drift distance

Vincent Lepeltier ILCD Collaboration meeting January 14th 2005

B=0.3 T

0.5 T

0.7 T

1.0 T

Page 10: L A ST RESULTS OF THE BERKELEY-SACLAY-ORSAY TPC COSMIC-RAY TESTS

10

transverse diffusion: 10-15% less measured diffusion than calculated by Magboltz B measurement calculationP10@140V/cm

0.3T 224 µmxcm-1/2 308 µmxcm-1/2

0.5T 171 229

1T 105 140

Ar-3%CF4 @200V/cm

0.3T 184 202

1T 80 8680 86

Ar-5%iso @221V/cm

0.1T 388 449

0.3T 308 355

0.5T 254 284

1T 177 193

1.5T 131 146Vincent Lepeltier ILCD Collaboration meeting January 14th 2005

Page 11: L A ST RESULTS OF THE BERKELEY-SACLAY-ORSAY TPC COSMIC-RAY TESTS

11

transverse diffusion: 10-15% less measured diffusion than calculated by Magboltz B measurement calculationP10@140V/cm

0.3T 224 µmxcm-1/2 308 µmxcm-1/2

0.5T 171 229

1T 105 140

Ar-3%CF4 @200V/cm

0.3T 184 202

1T 80 8680 86

Ar-5%iso @221V/cm

0.1T 388 449

0.3T 308 355

0.5T 254 284

1T 177 193

1.5T 131 146Vincent Lepeltier ILCD Collaboration meeting January 14th 2005

200μm @4T @1m!

potential transverse point resolution of 25μm

at 1m

Page 12: L A ST RESULTS OF THE BERKELEY-SACLAY-ORSAY TPC COSMIC-RAY TESTS

12

CONCLUSIONS

Vincent Lepeltier ILCD Collaboration meeting January 14th 2005

the Berkeley-Orsay-Saclay Micromegas TPC has been working well and has taken good data last Springanalysis will be finalized soon (spatial resolution) plans for the future: 1/ charge spreading with a resistive foil on Micromegas: resolution tests very soon with the IPN-Orsay point-like e- source tests are planed with the Carleton TPC next spring in the Saclay 2T magnet 2/ hadron beam tests at KEK with the MPI TPC equipped with a Micromegas @1.2T next Spring (or Autumn?) 3/ new cosmic-ray measurements with the large B-O-S TPC at 2T? 4/development and test of «bulk» Micromegas (with woven mesh) at Saclay.