KVA 15 30 45 75 112 150 225 300 - Marcus Transformer · efficiency standards mandated ... mandate and meets the most severe efficiency levels of the recommended DOE CSL-3 as ... 97.00

  • Upload
    ngonhi

  • View
    215

  • Download
    1

Embed Size (px)

Citation preview

EfficiEncy is in our DnA

EFFICIENCY IS IN OUR DNAEFFICIENCY AND ENERGY-SAVINGS IS PART OF OUR CULTURE

From the day the company was founded in 1942, Marcus Transformer has focused its technology on providing its customers with the most efficient and cost-effective products available on the market. Having set its own

high standards for over 60 years, Marcus already met the efficiency standards mandated early in the 21st century. The table below illustrates the efficiency of a Marcus Transformer in 1962 versus the recently mandated standards.

MARCUS SUPREME™: CONSTRUCTIONWhile loading varies depending on the application, no-load core loss is always present 24hours a day. Utility grade wound cores have been used solely for oil-filled, pole-mounted transformers where losses equal lost revenue. Marcus pioneered the application of the wound core to dry-type distribution transformers where losses equal lost revenue. First we introduced our single gap oval core, then the multiple-gap model and now finally the DG Octa-CoreTM.

2012: THE MARCUS SUPREME™ (MHE)Following the Marcus tradition of producing transformers with the lowest losses and therefore the Lowest Total Cost of Ownership we introduce the MARCUS SUPREME™. We have combined the Marcus technology with the most cutting-edge, modern materials available to produce the most effective transformers available today.

The MARCUS SUPREME™ generates a minimum of 33% less losses than the regulated standards (CSA C802.2 and NEMA TP-1) mandate and meets the most severe efficiency levels of the recommended DOE CSL-3 as seen in the chart below. This translates into significant dollar savings for both retrofit and new installations.

MARCUS SUPREME™ (MHE)vs.

DOE CSL-3 (% efficiency)

KVA 15 30 45 75 112 150 225 300

MARCUS % Efficiency (1962) 97.50 97.50 97.98 98.27 98.35 98.53 98.55 98.60

CSA C802.2 – NEMA TP-1 (% Efficiency 2005/2006) 97.00 97.50 97.70 98.00 98.20 98.30 98.50 98.60

KVA 15 30 45 75 112.5 150 225 300

MARCUS SUPREME™ 98.00 98.46 98.55 98.73 98.86 98.95 99.07 99.07

DOE CSL-3 97.97 98.29 98.45 98.64 98.77 98.86 98.97 99.04

Marcus Transformer Company1952

THE DISTRIBUTED-GAP WOUND COREAT THE HEART OF ENERGY SAVINGSAROUND THE CLOCK EFFICIENCY

ENERGY SAVINGS = $ DOLLAR SAVINGSThe installation of a MARCUS SUPREME™ in place of a less efficient transformer will result in a savings in both the short term and in the Total Life Cycle of the installation.

Projects ideally suited for the highest efficiency transformers are both retrofitting older facilities and upgrading new construction.

RETROFITSTransformers installed in buildings completed before the standards were implemented were not designed with efficiency in mind and consume more power than today’s units. The replacement of these transformers by the MARCUS SUPREME™ can provide significant savings and constitutes an excellent opportunity to reduce your electricity bill. In many cases, payback will occur in 2 to 4 years.

Example 1: Replacing a 45KVA non-compliant transformer, continuously loaded at 50%, by a MARCUS SUPREME™ will provide you with a $618 saving for one year, $18,540.00 over a thirty year period.

Example 2: Replacing a 112.5KVA non-compliant transformer, continu-ously loaded at 75%, 16 hours per day and 35% loaded 8 hours per day by a MARCUS SUPREME™will provide you with a $1,210.33 saving for one year, $36,310.00 over a thirty year period.

($1494 savings x 16 hours/24 hours + $643 savings x 8 hours/24 hours = $1,210.33 30 years x $1,210.33per year= $36,310 total)

NEW INSTALLATIONSAlthough transformers compliant with the present mandated minimum efficiency are superior to the older non-regulated units, the chart on the right, demonstrates how there are savings available by installing a superior transformer. The critical factor in the choice of transformers in a new installation should be the Total Cost of Ownership.

TOTAL COST OF OWNERSHIP = INITIAL COST + OPERATING COST

Since the MARCUS SUPREME™ has a life cycle of 30 years. The savings made during the life of the transformer far outweigh the initial purchase price.

This example shows the economy that can be achieved using a MARCUS SUPREME™ instead of transformer compliant to CSA 802 and DOE level 1.

Example: Using (4) x 225KVA, (2) x 150 KVA and (1) x 45 KVA at 35% continuous load. One year saving is 4 x 364 +2 x 280 + 2 x 117= 2230 The 30 years lifetime savings would be $66,900

MARCUS SUPREMETM KVA No-Load Losses 15 63 30 90 45 106 75 168 112.5 240 150 298 225 355 300 511

KVA 35% 50% 75% 100%

15 $190 $265 $372 $496

30 $344 $480 $777 $1,121

45 $446 $618 $1,061 $1,464

75 $619 $873 $1,413 $2,089

112.5 $643 $885 $1,494 $2,206

150 $884 $1,240 $2,315 $3,490

225 $1,200 $1,725 $2,799 $4,086

300 $1,274 $1,711 $2,661 $4,006

KVA 35% 50% 75% 100%

15 $42 $86 $170 $262

30 $77 $136 $246 $340

45 $117 $241 $455 $550

75 $154 $308 $482 $657

112.5 $210 $441 $785 $1,141

150 $280 $543 $1,043 $1,414

225 $364 $976 $1,557 $2,214

300 $373 $897 $1,577 $2,561

The table below shows the dollar savings over a year by installing a MARCUS SUPREME™ in place of a compliant transformer as a function of the % loading.

The table below shows the dollar savings over a year by replacing a non-compliant transformer with a MARCUS SUPREME™ as a function of the % loading.

MARCUS SUPREMETM

TYPICAL APPLICATIONS Hospital – Medical Center Nursing Home / Health Care Center Financial Buildings Industrial Facility Data Processing Centers Airport / Transportation Centers Light Industrial Facility Hotels Commercial Buildings Shopping Malls Office Buildings Schools – Colleges - Universities Public Buildings Government + Military Water Treatment Plants

TECHNICAL SPECIFICATIONSCoil Windings: CopperInsulation Class: 220°CTemperature Rise: 115°CK-Rating: K13Neutral: 200% CapacityElectrostatic Shielding: DoubleTaps: 4 -2 ½%, 2FCAN + 2 FCBN

Mounting: Wall or Floor as notedEnclosure: Nema 1Impedance: 2.5% to 4.5%Sound level: 3dB to 5dB below Nema ST-20

MARCUS SUPREME™ Dimensions + Weights

For Other Available Voltages, Contact Factory

PART NUMBER Dimensions Weight MOUNTING

KVA 600V PRIMARY 480V PRIMARY (Inches) (lbs.) W – Wall

120/208 SECONDARY H x W x D F – Floor

15 MHE15A1 MHE15B1 23 x 21 x 14.3 250 W/F

30 MHE30A1 MHE30B1 27 x 25.5 x 16.4 360 W/F

45 MHE45A1 MHE45B1 27 x 25.5 x 16.4 510 F

75 MHE75A1 MHE75B1 36.3 x 30.4 x 20 790 F

112.5 MHE112.5A1 MHE112.5B1 36.3 x 30.4 x 20 1100 F

150 MHE150A1 MHE150B1 47 x 35 x 24.5 1500 F

225 MHE225A1 MHE225B1 47 x 35 x 24.5 1900 F

300 MHE300A1 MHE300B1 51.7 x 36.5 x 30.8 2500 F

FEATURES Qualifies for Available government energy efficiency rebate

programs

30 years life cycle

Offers built-in overload capacity for short term requirements

Eliminates 3rd harmonics in the magnetic circuit

Environmentally friendly “green” designs

Reduces ambient temperatures in confined electrical rooms

Provides less than 2.5% voltage regulation to sensitive equipment

Fitted with connection screw-type lugs

Rigorous testing ensures maximum reliability

Pro-rated 30 Year Limited Warranty*

OPTIONS Custom voltages

Special primary taps

50Hz designs for international applications

Sprinkler shields and weather-resistant (3R) Enclosures

Resin-Encapsulated and 4x Enclosure

80°C operating temperature rise

0° Primary to secondary phase displacement

Custom enclosure paint colors

CONTACT FACTORY FOR AVAILABILTY OF OPTIONS FOR SPECIFIC RATINGS

Reduces Electrical Waste

Replaces Outdated Performers

Lowers Utility Bills

Reduces Carbon Emissions and Greenhouse Gas Emissions

Offers a 30 Year Life Cycle

T. 1-800-267-7376 • F. 1-866-205-7526

www.MarcusTransformer.com