Upload
doanngoc
View
214
Download
1
Embed Size (px)
Citation preview
__________
PELET STOVE FOR CENTRAL HEATING
Aqua ECOLOGIC
Instructions for use, maintenance and installation
September 2015
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
2
→ Pellet fuel from timber biomass biofuels →
INSTRUCTIONS FOR CONNECTING, OPERATION, AND MAINTENANCE OF THE STOVE
Heating devices (in this manual they are called “stoves") by Gorenje d.d. (in this manual titled Gorenje) are assembled and tested in accordance with the safety and applicable measures, and regulations of the European Community.
This manual is intended for users of the stoves, contractors who install the stoves, operators and workers for stove maintenance that is shown on the front page of the manual.
If you do not understand something in this manual, please contact our professional services or an authorized service center. In doing so, always specify the number of the chapter where there is some ambiguity.
Printing, translation and reproduction, even in part, of this manual is subject to licensing by Gorenje, d.d., which means that Gorenje d.d. must approve these actions. Technical information, figures, and specifications in this manual must not be given to a third party.
WARNING:
IMPORTANT: Connecting the appliance to the electrical installation must be carried out by qualified and authorized persons in accordance with applicable regulations.
This appliance is not intended for use by persons (including children) with reduced physical, motor, and mental capabilities, or to persons with a limited knowledge and experience in the absence of the person responsible for their safety or care.
Children cannot be allowed to play with this appliance.
DOUBLE COMBUSTION SYSTEM
The flame obtained by proper combustion of the pellet in the stove emits the same amount of carbon dioxide (CO2), which would be freed as a result of the natural decay of wood.
The amount of carbon dioxide (CO2) obtained through combustion or decomposition of plant mass corresponds to the amount of carbon dioxide (CO2) which the plant mass is able to obtain from the environment and to transform it into air and carbon of the plants during its entire lifetime.
The use of non-renewable fossil fuels (coal, oil, gas), contrary to what happens with the wood, releases into the atmosphere huge amounts of carbon dioxide (CO2), that have been gathering up for millions of years, creating a greenhouse effect. The use of wood as fuel is therefore perfectly balanced with the environment, because the wood as a renewable fuel is in ecological harmony with nature.
Using the principle of clean combustion, we fully achieve these objectives, and so Gorenje, d.d. has directed its development and all activities towards fulfilling this goal.
What do we consider clean combustion and how does it work?
Controlling and adjusting the primary air and injecting the secondary air causes secondary combustion, or the so-called post-combustion, which provides a secondary flame that is by its nature lighter and stronger than the primary flame. The addition of a new oxygen (inserted through the air) allows further combustion
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
3
of gases that are not completely burned. This significantly increases the thermal efficiency and reduces harmful emissions of carbon monoxide (CO), because the incomplete combustion is minimized.
TABLE OF CONTENTS
1. TECHNICAL CHARACTERISTICS OF THE STOVE .............................................................................. 5
2. THE TASK PURPOSE OF THIS MANUAL ............................................................................................... 5
2.1 UPDATES ........................................................................................................................................... 5
3. RESPONSIBILITIES OF THE MANUFACTURER ................................................................................... 6
3.1 GENERAL CHARACTERISTICS OF USERS .................................................................................... 6
3.2 TRANSPORTING AND USING THE STOVE - HANDLING ............................................................... 6
3.3 RESPONSIBILITIES OF THE INSTALLER ........................................................................................ 6
4. INSTALLATION – STOVE INSTALLATION.............................................................................................. 7
4.1 INSTALLING THE STOVE .................................................................................................................. 7
4.2 THE SMOKE EXHAUST SYSTEM ..................................................................................................... 9
4.3 INSULATION AND THE DIAMETER OF THE OPENING (HOLE) ON THE ROOF (OR IN THE
WALL) ..................................................................................................................................................... 13
4.4 COMBUSTION AIR SUPPLY ........................................................................................................... 15
4.5 CONNECTING THE POWER ........................................................................................................... 16
5. IMPORTANT INSTRUCTIONS ............................................................................................................... 17
6. WARNING SAFETY MEASURES FOR STAFF ..................................................................................... 17
6.1 WARNING SAFETY MEASURES FOR THE USER ........................................................................ 18
7. SAFETY GUIDILINES FOR IGNITION AND CLEANING OF THE STOVE ........................................... 19
7.1 ROUTINE CLEANING AND MAINTENANCE DONE BY THE USER OF THE STOVE ................. 19
7.2 CLEANING AND MAINTENANCE (for employees who do maintenance) ....................................... 22
7.3. SPECIAL MAINTENANCE ............................................................................................................... 23
8. IMPORTANT SAFETY INFORMATION .................................................................................................. 23
9. THE PELLET QUALITY IS VERY IMPORTANT .................................................................................... 24
9.1. STORING THE PELLET .................................................................................................................. 24
10. CONNECTING THE HYDRAULIC INSTALLATIONS ........................................................................... 25
11. PRESSURE AND RETURN PIPE ........................................................................................................ 26
12. BUILT-IN COMPONENT OF THE STOVE ........................................................................................... 26
12.1. SAFETY VALVE ............................................................................................................................. 27
12.2. CIRCULATION PUMP ................................................................................................................... 27
12.3. AUTOMATIC AIR VALVE ............................................................................................................. 27
12.4. EXPANSION VESSEL ................................................................................................................... 27
12.5. CHARGING AND DISCHARGING TAP ......................................................................................... 27
13. INSTALLING AND IGNITING ............................................................................................................... 28
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
4
14. PRACTICAL INSTRUCTIONS AND TIPS FOR THE USE OF THE HEATING SYSTEM ................... 28
15. FILLING WITH WOODEN GRANULES ................................................................................................ 28
16. DESCRIPTION AND MODE OF OPERATION OF THE CONTROL SYSTEM .................................... 29
16.1. DESCRIPTION OF THE PUSH BUTTON DISPLAY ..................................................................... 29
16.2. WHEN THE BOILER IS ON ........................................................................................................... 33
16.3. TURNING THE BOILER OFF ........................................................................................................ 33
TURNING THE BOILER ON ................................................................................................................... 33
16.4. SETTING UP THE TIME-CONTROLLED PROGRAM .................................................................. 34
16.5. SIGNS AND MESSAGES ON THE DISPLAY ............................................................................... 36
16.6. ELECTRICITY SCHEME ............................................................................................................... 38
16.7. MENUS .......................................................................................................................................... 39
16.8. ALARMING .................................................................................................................................... 40
17. SAFETY MEASURES ........................................................................................................................... 47
18. FAILURES - CAUSES – SOLUTIONS .................................................................................................. 48
19. INFORMATION ON DISPOSING (THROWING AWAY) AND DISMANTLING (PULLING APART) OF
THE STOVE ................................................................................................................................................ 50
20. THE DURATION OF GUARANTEED SERVICE .................................................................................. 51
20.1. WARRANTY TERMS AND CONDITIONS ..................................................................................... 51
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
5
1. TECHNICAL CHARACTERISTICS OF THE STOVE
1. Dimensions of the stove:
width 574 mm depth 568 mm height 1237 mm
2.Flue terminal diameter 80 mm 3.Diameter of exterior air intake on the wall 100 mm 4.The height from the floor to the axis of the flue terminal 350 mm 5.Maximum stove power (radiation of water included) 18,5 KW 6.Radiation stove power at maximum power 3,5 KW 7.The power of a water heater at maximum power 15KW 8.The maximum consumption 4,0 kg/h 9.Degree of efficiency at maximum power 92 % 10.Minimum stove power (radiation of water included) 7,02 KW 11.Radiation stove power at minimum power 1,52 KW 12.The power of a water heater at minimum power 5,5 KW 13.The minimum consumption 1,7 kg/h 14.Degree of efficiency at minimal power 90% 15.Minimum draft 5 Pa 16.Optimal draft 12 Pa 17.Heating volume 240 - 310 m3 18.The capacity of the fuel reservoir 45 kg 19.The maximum working time with a full reservoir 40 h 20.The minimal working time with a full reservoir 11 h 21.Maximum output power 450 W 22.Voltage and frequency 230V/50Hz 23.The weight of the stove:
net 193 kg gross 222 kg
2. THE TASK PURPOSE OF THIS MANUAL
The purpose of the instructions is to enable the user to take all the necessary measures in order to ensure safe and proper use of the stove.
2.1 UPDATES
This manual reflects a work of art at the moment when the stove was placed on the market. Therefore, GORENJE does not take into account the stoves that are already on the market with the appropriate technical documentation and considers them as defective or inadequate after any kind of modification, adaptation or application of new technologies to newly produced machines.
The contents of this manual should be carefully read and studied. It is necessary to strictly follow all the instructions given in this manual. All information contained in this manual is necessary for proper connection, use, and maintenance of your stove.
Therefore, this manual has to be carefully stored for the necessary instructions in the event of any problems or concerns.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
6
If the stove is given or sold to another person, the new owner must also be given this instructions manual.
If you have lost your manual, the manufacturer can provide you with a new one.
3. RESPONSIBILITIES OF THE MANUFACTURER
In issuing these instructions, GORENJE accepts no civil or legal liability, direct or indirect, due to:
Accidents caused by not respecting the standards and specifications given in this manual,
Accidents caused by improper handling or use of the stove by the user,
Accidents resulting from modifications and repairs, which were not approved by GORENJE,
Poor maintenance,
Unforeseen events,
Accidents resulting from the use of spare parts that were not original or not intended for these models of stoves.
Responsibility for connecting is fully assumed by the installer - contractor.
3.1 GENERAL CHARACTERISTICS OF USERS
The user of the appliance must have the following basic characteristics:
be an adult and responsible person,
have a specific technical knowledge that is needed for routine maintenance of electrical and mechanical components of the stove.
CHILNDREN ARE NOT ALLOWED NEAR THE STOVE OR TO PLAY WITH IT WHILE IT IS ON.
3.2 TRANSPORTING AND USING THE STOVE - HANDLING
When using the stove, it is necessary to be careful and not allow the stove to tilt forward. This is because the brunt of the stove is forward. During transportation of the stove, which has to be completely safe, make sure that the forklift has the load that is greater than the weight of the stove that it is supposed to lift. Avoid twitching and jerking movements. ALL PACKAGING SHOULD BE REMOVED SO THAT IT IS OUT OF REACH OF CHILDREN, BECAUSE THE MATERIALS THAT ARE INSIDE CAN LEAD TO CHILDREN SUFFOCATING. THESE INCLUDE PLASTIC BAGS, FILM, POLYSTYRENE, ETC.
3.3 RESPONSIBILITIES OF THE INSTALLER
Installer's responsibility is to do all the tests of the flue pipeline, air supply, and all the things that are necessary for connecting (installing) your stove. Installer's responsibility is to adjust the stove to local regulations which apply where the stove is connected (installed).
The use of the stove must be in accordance with the instructions for use and maintenance, as well as with all the security standards that are given by the local regulations that apply where the stove is connected (installed).
The installer has to check:
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
7
the type of stove to be connected,
whether the room corresponds to the stove where the stove will be installed, which is expressed as the minimum size required for installation, set forth by the manufacturer of the stove,
heat generator
manufacturer's instructions regarding the requirements of smoke removal systems (ducts and pipes for smoke exhaust),
inner cross section of the chimney, the material out of which the chimney is made, uniform cross section,
that there are no disturbances and obstacles in the chimney,
height and vertical extension of the chimney,
altitude at the place of connecting the stove,
the existence and suitability of the protective cover for the chimney that is resistant to the wind,
the possibility of securing the external air supply and the size of the necessary openings,
Simultaneous use of stove that needs to be connected with other equipment that already exists at that place.
If the results of all checks are positive, then we can proceed with connecting the stove. Make sure you follow the instructions of the manufacturer of the stove, as well as the standards for fire protection and the safety standards provided.
When you are finished connecting, the stove has to be turned on in trial mode for at least 30 minutes to test if the stove is working properly.
When the installation and important details are completed, the installer must provide the client the following:
Instructions for use and maintenance issued by the manufacturer of the stove (if such instructions are not provided with the stove),
The documentation necessary to comply with the existing standards.
4. INSTALLATION – STOVE INSTALLATION
Responsibility for the work carried out at the place of connection is entirely on the user.
Before one turns the stove on, the installer must meet all legal standards of safety, as well as the following requirements:
to check that setting up the stove complies with local, national, and European regulations,
that the location of setting up the stove meets the requirements set forth in this manual,
to set up the flue pipes,
that air intake matches the type of the installed stove,
that the electrical connections are not set up using temporary and/or not insulated electrical cables,
to evaluate the effectiveness of grounding electrical systems,
to always use personal protective equipment and all means of protection that are prescribed by local regulations,
to always provide sufficient service space required for any maintenance and repair of stoves
4.1 INSTALLING THE STOVE
We recommend you to unpack the stove only when the stove is set up in the position where it will be connected.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
8
The stove is on the plastic pins that have M10 bolts (4 items), that are threaded into the stove base. At the screws there are M10mm threaded nuts to the plastic parts. The legs are wound up all the way to the base of the stove. After unpacking the stove, when you put it in a place where it will be located, it is necessary to unscrew all the legs, so that a total height from the floor to the base of the stove is about 25mm. When you are done with nivelation of the stove that needs to stand horizontally, tighten the nuts with a 17 wrench, which needs to approach the base of the furnace, and at the same time hand-holding the plastic part of the legs, tighten the nut. The height of about 25mm from the floor to the base is needed for better circulation of air and cooling the stove. In this way you protect the stove from overheating and you extend its life.
If the surrounding walls and/or floors are made of materials that are not resistant to heat, then one should
use adequate protection using the insulating material that does not burn.
Always make sure that you leave a safe distance (about 35/40 cm) between the stove and furniture, home appliances, etc. To protect the floor if it is made of combustible materials, we suggest you put a metal plate under the stove on the floor with the thickness of 3-4 mm that will stretch 30 cm in front of the stove.
The stove must be at least 25 cm away from the surrounding walls. Always leave at least 15 cm between the rear side of the stove and the wall to allow for proper air circulation, or for the air to flow properly in that area.
If the stove is installed in a kitchen with a trellis for drawing out air or if it is placed in the room with appliances that use solid fuel (such as a wood burning stove), always make sure that the amount of inlet air in the room is sufficient to ensure safe operation of the stove.
If a smoke channel goes through the ceiling, it should be properly thermally insulated using the protection out of insulating materials that does not burn. When the stove is set up into place, it should be levelled using pins.
DANGER !
The exhaust gas Armour must not be connected to:
- the smoke pipe used by another heat generator (boilers, furnaces, fireplaces, stoves, etc.),
- the air drawing system (grilles, ventilation openings, etc), even if the system is inserted into the drain pipe.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
9
DANGER !
It is forbidden to install shut-off valves for the flow (draft) of air (flap valves that can prevent airflow or disable drafts).
ATTENTION
If the ejection path of smoke creates such a bad draft, of a bad flow of air (many curves, improper completion of the ejection of smoke, constriction, etc.) discharge of smoke can be bad, or in a situation like this smoke discharging is not as good as it could be.
The smoke ejection system from the stove operates under negative pressure in the stove chamber and with mild pressure from the smoke drain pipe. It is very important that the smoke extraction system is hermetically closed (sealed). This requires the use of a smooth tube on the inside. First of all you must carefully study the plan and structure of the room when the smoke extraction pipe is set up through the walls and roof, so that the installation of pipes is performed properly in accordance with the standards of fire protection.
You should first ensure that the room where the stove is located has enough air for combustion. It is advisable to periodically performs check so as to ensure that the combustion air comes right up to the combustion chamber. The stove operates at 230 V ~ 50 Hz. Make sure that the electrical cord is not underneath the furnace, to be away from the stove, to be away from hot spots, and not to touch any sharp edges that it could interdict. If the stove is electrically overloaded, this can lead to shortening of the lifetime of the electronics of the stove. Never turn off the power supply by pulling the plug when there is a burning flame in the stove. This could jeopardize the proper functioning of the stove.
4.2 THE SMOKE EXHAUST SYSTEM
The smoke exhaust must be carried out in accordance with existing standards. Exhaust gas tube should be well sealed (see Figures 1-7).
For smoke exhaustion, one can also use classic brick chimneys while flues can also be made of pipes that need to be well insulated (double wall) and sealed, to avoid creating condensation in them. The drain tube absolutely must not be connected to other systems of any kind, such as the systems where the smoke is removed from the combustion chamber, exhaust grilles or air distribution system, etc. Also, the smoke exhaust must not be set up in enclosed or semi-enclosed areas such as garages, narrow corridors, underground passages, or at any other places where they is smoke. When the stove is connected to the exhaust gas pipeline, it is necessary to bring professional chimneysweep to verify that the chimney does not even have the tiniest cracks or fissures. If in the exhaust gas chimney there are such cracks, the pipe for smoke exhaustion must be wrapped in insulation for proper functioning.
For this purpose, the tubes that can be used are solid and made of painted steel (minimum thickness 1.5 mm) or from stainless steel (minimum thickness 0.5 mm).
The smoke extraction system (chimney) out of metal pipes must have a grounding in accordance with existing standards and regulations. Grounding is required by law.
The grounding connection must be separated from the grounding for the stove.
The smoke exhaustion pipe must be done according to the standards in terms of dimensions
and materials used for its construction (Figure 1).
A) The top of the chimney is resistant to wind
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
10
B) Maximum cross section is 15 x 15 cm or a 15-cm diameter, with the maximum height of 4-5 m.
C) Gasket
D) Inspection hole - for control
Flue pipes that are in poor shape, or are made out of inappropriate materials (asbestos cement, galvanized sheet, etc. with rough or porous surfaces) are inadequate and jeopardize the proper functioning of the stove.
The smoke can be drained through a classic smoke pipe (see next Figure), provided that it meets the following requirements:
- Check the maintenance of the drain flue pipes or chimneys. If the smoke drain pipe is old it should be replaced with a new one. If the chimney is damaged it is good to repair it or rebuild it by inserting a steel pipe that is properly insulated with mineral wool.
- The smoke can be discharged directly into the smoke pipe (chimney) only if it has a cross-section of up to 15 x 15 cm, or a diameter of up to 15 cm, and if there is a cover for checking and cleaning.
- If the chimney has a larger cross section than 15x15cm, or a diameter greater than 15cm, a possible
increased regulation of draft (its decrease) in the chimney can be made in three ways:
1. If in the bottom of the chimney there is an opening for cleaning it should be partially open.
2. Insert a steel pipe in the chimney with a diameter of 10cm, if there is a possibility for such reparation of the chimney.
3. By adjusting certain parameters in the stove. This adjustment must be done only by an authorized service of GORENJE.
- Make sure that the connection to home chimney is properly sealed.
- Avoid contact with material that burns easily (such as wooden beams), and in all cases they should be isolated with anti-fire material (see Figure 2).
A) Mineral wool
B) Steel pipes
C) A baffle plate.
The stove is designed to be connected to the chimney flue pipes with a diameter of 80mm. If you are not using a standard chimney, but you have a new chimney, or you are modifying the existing one, use insulated stainless pipes (double wall) with a diameter given in Table 1. Flexible pipes are not permitted.
SYSTEM TYPE DIAMETER mm SYSTEM MARK
Pipe length less than 5 m 80 acceptable
Pipe length more than 5 m 100 required
To be installed in places above 1,200 meters above sea level 100 recommended
Table 1
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
11
Figure 1 Figure 2
When using the connecting pipe between the stove and the flue drain pin, be sure to use a "T" connector (as shown in Figures 5 and 6), with the clean-out cover (cap) next to the stove. Applying the "T" connector must enable the collection of ash, which is produced inside the tube, and the smoke drain pipe must occasionally be cleaned without having to remove the tube. The smoke is under mild pressure and therefore it is required to check the cover (cap) for cleaning the exhaust gas system that is perfectly sealed and it remains so after each cleaning. Make sure to perform the same sequence for assembly and check the condition of the seals.
Install the flue pipes pursuant to Figure 7.
It is strictly recommended to avoid the use of horizontal extensions, and if necessary, make sure that the pipe is not bent but that it has the slope of at least 5%. The horizontal part of the drain flue pipes must not in any case exceed the length of 3 m.
It is not recommended to connect the smoke exhaust directly to the stove with a horizontal part longer than 1 m. See Figures 4,5,6 and 8. After the T branch it is necessary to set up a vertical extension of Ø 80mm in length for at least 1-1.5 m, and only after that to move to the horizontal extension of Ø 80mm and a vertical extension of Ø 80 or Ø 100mm, depending on the height of the flue pipe (chimney) as shown in Table 1.
When connecting the stove to the chimney using fittings, one must install a knee with a hole for cleaning
(Figure 2a). Using the knee with an opening for cleaning allows for regular cleaning, without the need to
dismantle the pipes. Drain gases in the chimney connector are under mild pressure so it is necessary to
check that the cover for cleaning the ashes is completely sealed and to seal it after each cleaning. Please
make sure everything is properly returned to its place, and check the condition of the seals.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
12
Figure 2a: Cleaning elements
Ideal vacuum primarily depends on the absence of barriers such as narrowing and/or corner connectors. It is recommended that the knees are 30°, 45 °, and 90 °. Knee at 90 ° shall be three-fold (Figure 2b).
In any case, it is necessary to ensure that the initial part of the vertical flue pipe has the length of at least
1.5 m. Only in this way can you achieve the proper removal of flue gases.
Figure 2b:
In Figure 3, left, we show how a complete (top) is supposed to look like when you have two chimneys next to each other, and in Figure 3, right, how not to do the end part.
Figure 3
YES
YE
NO
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
13
4.3 INSULATION AND THE DIAMETER OF THE OPENING (HOLE) ON THE ROOF (OR IN THE WALL)
Once you determine the position of the stove, it is necessary to make a hole through which a smoke pipe must pass. This varies depending on the type of installation, diameter of the exhaust gas pipe (see Table 1) and the type of wall or roof for the tube to pass. See Table 2. Insulation needs to be made out of mineral wool with a nominal density greater than 80 kg/m2.
Figure 4
Figure 5
1. Armature 80> 100
2. A hose fitting with a T shape
Ø100
Ø80
STOVE
WALL
CHIMNEY T-
PIECE
REDUCER
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
14
Figure 6
1. A hose fitting with a T shape - a T connector pipeline
2. Cleaning direction
3. Opening, a window for servicing/inspection
4. Cleaning direction
5. A hose fitting with a T shape - a T connector pipeline
6. Cleaning direction
7. A pressure lid for cleaning (plug-in)
Figure 7: Mounting the flue pipe
Insulation thickness
mm
Diameter of the smoke exhaust pipe (mm)
D.80 D.100
Diameters of the holes (holes) to be made (mm)
5
4
3
6
1
2
7 7
Ø100
Ø80
7
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
15
The walls are made of wood, or in any case, flammable, or parts that are flammable.
100
150
170
Concrete wall or a roof 50 100 120
A wall or a brick roof 30 100 120
Table 2: Insulation thickness for the part of the system that passes through the wall or roof
Above all it is necessary to provide the PERFECT AIRFLOW (draft) in pipes for smoke exhaustion that has to be free, without any obstacles, such as different narrowing or corners. All displacements of the axis must have a tilted orbit with a maximum angle of 45 degrees from the vertical, while 30 degrees is the best solution. This displacement would be best done near the top of the chimney resistant to the wind.
According to the regulations (the top of the chimney resistant to wind, distance, and placement of the stove) the distances shown in Table 3 must be met:
Roof slope: The distance between the ridge and the chimney cap
Minimum height of the chimney measured at the top slot (at the back of the chimney)
α Distance in meters Height in meters
150 less than 1.85 m greater than 1.85 m
0,50 m above the ridge
1,00 m from the slope of the roof
300 less than 1.50 m
less than 1.50 m
0,50 m above the ridge
1,30 m from the slope of the roof
450 less than 1.30 m
greater than 1.30 m
0,50 m above the ridge
2,00 m from the slope of the roof
600 less than 1.20 m
greater than 1.20 m
0,50 m above the ridge
2,60 m from the slope of the roof
Table 3
However, it is required to provide an initial vertical extension of 1,5 m (minimum) in order to provide proper discharge of smoke.
4.4 COMBUSTION AIR SUPPLY (Figure 8)
The air required for combustion, which is taken from the environment, must be supplied by a single ventilation grill mounted on the outer wall of the room. This will ensure better combustion and thus lower consumption of pellets. It is not recommended to have outside air drawn directly from the tube, as it will reduce the efficiency of combustion. A ventilation shaft must always be equipped with one ventilation grille on the outer side as protection from rain, wind, and insects.
This hole must be made on the outer wall of the room where the stove is located.
The supply of combustion air from the garage, a warehouse for combustible materials, or from a room where there are risks of fire is prohibited.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
16
The opening of the outer supply of combustion air must not be connected by pipes.
If the room has some other devices for heating, the supply of combustion air must ensure the amount of air that is required for proper operation of the device.
Figure 8: Minimum gaps for setting up ventilation grilles.
For proper and safe placement of ventilation grilles see data given in Table 4. These are the minimum distances from each airspace or smoke extraction. This value can change the configuration of the air pressure. It should correspond to the ordering to secure that the open window draws outside air, depriving the stove of it.
Ventilation grid must be set up at least
1 m under doors, windows, gas exhausts, air chambers, etc.
1 m horizontally from
0.3 m above
2 m from the smoke exhaust
Table 4: The minimum distance for the supply of combustion air
4.5 CONNECTING THE POWER
These stoves are connected to electricity. Our stoves have electrical cables that are suitable for medium temperature. If you need to replace the power cord (if it is damaged, for example) then consult with our authorized technical staff. Before you plug in the electric stove note the following:
- That the characteristics of electrical systems correspond to the information that is specified in the data on the identification plate on the stove.
- If the smoke extraction system is metal, it must have a grounding terminal in accordance with the existing standards and legislation. Grounding is the law.
- The electrical cable must not at any time reach a temperature that is 800C above the ambient temperature. When the stove is installed and placed in its spot, a bipolar switch or socket must be easily accessible.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
17
- If the stove is not used for a long time, unplug it or switch to the switch off (0) position.
In the event of failure or malfunction, turn off the stove right away or switch to a switch off (0) position and contact an authorized service center.
5. IMPORTANT INSTRUCTIONS
THE FOLLOWING INSTRUCTIONS ARE REQUIRED FOR THE SAFETY OF PEOPLE, ANIMALS, AND PROPERTY.
We wish to inform the installer of the stove on some of the general guidelines which must be followed for proper installation and for proper stove mounting. These standards are required, but not completely. For further and more detailed information one needs to read the rest of this instructions manual.
- Plug the stove into an outlet that is grounded. Figure 9
- The switch on the rear of the stove is set to position 1. Figure 10
- Do not allow children or pets to be near the stove.
- Use pellets only, not other fuel.
- Notify all users about the potential risks and dangers and teach them how to handle the appliance.
- If the stove is placed on a wooden floor, then it is recommended to isolate the pedestal on which it stands.
The stove operates with a combustion chamber, which is in the negative pressure. Therefore, make sure that the smoke is well thermally insulated.
When the stove is turned on for the first time then, due to the stabilization process a small amount of paint (not harmful to health) that covers the stove vaporizes. It is therefore necessary to air the room so that it is cleared from the fumes.
Figure 9 Figure 10
6. WARNING SAFETY MEASURES FOR STAFF
MAINTENANCE
The contractors who work in maintenance, in addition to following all safety measures, must:
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
18
- Always use safety equipment and personal protective equipment,
- Turn off the power supply before they start working,
- Always use the appropriate tools,
- Before they begin any work on the stove they need to keep in mind that it should be cold and that the ashes should be cold as well. They need to make sure the handles are cold as well.
− NEVER TURN THE STOVE ON if there is just one of the safety devices that is defective, improperly set
up or it does not work at all.
- Do not make modifications of any kind, for any reason, other than those permitted and explained by the manufacturer himself.
- Always use original spare parts. Never wait until the components wear out before you replace them.
Replacing the worn parts, or the components of the stove before they stop working contributes to the prevention of damage caused by accidents due to sudden failure, or breaking of the components, which can lead to serious consequences for people and/or property located around the stove.
- Clean the firebox before lighting the stove.
- Make sure there is no condensation. If condensation occurs it shows that there is water from the cooling smoke.
We recommend you find the possible causes to be able to establish a regular and correct operation of the stove.
6.1 WARNING SAFETY MEASURES FOR THE USER
The place where the stove is to be set up, called the mounting place, must be prepared by local, national, and European regulations.
The stove is a “heating machine" and while it is on it has outer surfaces that are very hot or that achieve very high temperatures.
This stove is designed to burn fuel from pressed wood mass (a pellet with a diameter of 6 mm to 7 mm, with the length of 30 mm, with maximum moisture 8-9%).
It is therefore very important to pay attention to the following when the stove is on:
- Do not approach and touch the glass on the door, there is a BURNING HAZARD
- Do not approach and touch the smoke drain pipe, there is a BURNING HAZARD
- Do not do any cleanups
- Do not open the door because the stove is working properly only when it is sealed
- Do not throw away the ashes when the stove is ON
- Children and pets need to stand away from the stove
- FOLLOW ALL INSTRUCTIONS GIVEN IN THIS MANUAL
Likewise, the proper use of biofuel pellets means:
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
19
- Only use the fuel that meets the manufacturer's instructions,
- Always follow the maintenance plan for the stove,
- Clean the stove every day (only when the stove and the ash are cold),
- Do not use the stove in case of any defects or abnormalities, in the case of unusual noise and/or suspected faults,
- Do not spray water on the stove, even when firefighting,
- Do not turn off the stove by pulling the plug. Use the button on the board to turn off,
- Do not tilt the stove, IT MAY BECOME UNSTABLE,
- Do not use the stove as a support or a holder. Never leave the tank lid open.
- Do not touch the dyed parts of the stove while it is ON,
- Do not use wood or coal as a fuel, but only the pellet with the following characteristics: diameter of 6-
-7 mm, maximum length 30 mm, maximum moisture content 8-9%,
- Do not use the stove to burn waste,
- Always perform all operations with maximum security measures.
7. SAFETY GUIDILINES FOR IGNITION AND CLEANING OF THE STOVE
- For turning the stove ON never use gasoline, kerosene or any other flammable liquid. Keep these types of fluid away from the stove while it is running,
- Never turn the stove ON if the glass is damaged. Do not strike the glass or the door so that they do not get damaged,
- While the stove is ON, do not open the door to clean the glass. Clean the glass only when the stove is cold, using a cotton cloth or paper towel and a glass cleaner,
- Make sure the stove is secure to prevent any movement,
- Make sure that the ash box is inserted and that it is fully closed, so that the doors are leaning properly on the box,
- Make sure the stove door is firmly closed while the stove is ON,
- Use a vacuum cleaner to pull the ashes from the stove only when the stove is completely cool,
- Never use abrasive cleaners for cleaning the surface of the stove.
7.1 ROUTINE CLEANING AND MAINTENANCE DONE BY THE USER OF THE STOVE
Use a drum shaped vacuum cleaner that can facilitate cleaning the stove. The vacuum cleaner must have a filter that will prevent the sucked dust to go back into the room where the stove is located.
Before you get started with routine maintenance, including cleaning, take the following precautions:
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
20
- Turn off the stove from the power supply before you start doing anything,
- Before you start doing anything make sure the stove and the ash are cool,
- Use the vacuum cleaner to vacuum up the ash from the combustion chamber every day,
- Using the vacuum cleaner carefully clean the firebox every day (after each use and when the stove is cool)
- Always make sure the stove and the ashes are cool.
- FIREBOX (box-shaped) - it burns the pellets made out of wood mass. See Figure 11. It is recommended that the firebox be vacuum cleaned after each use, every day (when the stove is cool). Every day, it is recommended to take out the firebox and to make sure that there is no residual ash at the bottom of it, as well as unburned pellets that were collected at the bottom of the firebox. Then put the firebox back and set it firmly into place to ensure the safe running of the stove. The firebox must sit straight - horizontal, it must not be tilted! The sealing tape from the underside of the firebox must be in its place, and must not be damaged.
If you are not sure, do not hesitate to call an authorized service center for explanation and additional information, since the manufacturer does not know what the situation is with the connection and maintenance of the stove and gives no warranty for the connection of the stove and its maintenance.
The manufacturer does not assume any responsibility for damage caused by third parties.
Figure 11
2. The hole for inserting the heating element to burn fuel
1. For the best operation of the stove, all holes must be free of ash
Figure 11
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
21
The ash container should be vacuumed or emptied if it is full.
Make sure the stove and the ash are cool.
Upper ash container must be cleaned every or every other day, by vacuuming or by simply throwing the ashes away. This will get rid of any impurities that remain inside when the pellets are burning. The container then has to be returned to its proper place. Never put a pellet that has not burned in the ash container.
Lower ash container must be cleaned once every seven or 10 days, by vacuuming or by simply throwing the ashes away. Before that, loosen the two butterfly nuts. This will get rid of any impurities that remain inside when the pellets are burning.
At the same time, use a vacuum cleaner to suck up the ash in the smoke chamber through an opening in the front of the boiler bottom ash tray.
The container then has to be returned to its proper place.
- SMOKE PIPES IN THE BOILER
They need to be cleaned manually with a special key for every 40-50 kg of spent pellets (one full tank of pellet). First use the key to lift up small round lids with openings, two of them, that are located on the cover of the stove at the top. Using the same key go into the openings of the lever - the pins which are connected to the cleaning levers, and dust them a few times by lifting them up and putting them down, as shown in Figure 12.
Figure 12 Figure 13
- UPPER SMOKE CHAMBER
Should be manually cleaned for every 90-100 kg of spent pellets (two full tanks). Lift the tank lid for the pellet. In the tank, in the upper front part, under the lid, there is a button for the chamber cleaning mechanism. By pulling the mechanism button a few times back and forth you will clean the chamber. Do not worry if the mechanism moves slowly, if it scratches, or gets caught. This is how it cleans the chamber.
Clean the stove only when it is cold. At the end of the cleaning, push the button all the way back (pull it) so that you can see the button and the bar of the cleaning mechanism. See Figure 13.
-GLASS DOOR (check and clean periodically):
Make sure the stove and the ash are cool.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
22
Clean the glass with a soft cloth. Glass is made from pyrocheramics resistant to high temperatures. In case of damage, before re-using the stove, replace the glass. The glass must be replaced only by the authorized persons.
Smoke exhaust fan area should be checked and cleaned every six months.
Make sure the stove and the ash are cool.
Cleaning the interior flue exhaust is done by first removing the cover on the bottom of the box for the ashes and inserting the vacuum cleaner hose through that hole, as to vacuum out the remaining ashes, Figure 14.
Figure 14
- GENERAL CLEANING AT THE END OF THE HEATING SEASON
Make sure the stove and the ash are cool - unplug the stove from the power supply.
At the end of the heating season, to be safe, unplug the stove from the power supply. It is important to clean and check the stove, as explained in the above points.
Make sure the stove and the ash are cool.
After prolonged use, it is possible that the asbestos tape for sealing the door separates. This sealing tape sticks to the door with silicone resistant to high temperatures. To resolve this, tape the back of it using an adhesive that is resistant to high temperatures. This is very important for good sealing of the doors.
7.2 CLEANING AND MAINTENANCE (for employees who do maintenance)
FLUES - CHIMNEY should be cleaned every six months or after burning two tons of pellets.
Make sure the stove and the ash are cool.
The smoke channel (chimney) is resistant to wind and has to be checked and cleaned every year, best at the beginning of the heating season. It is best to pay the authorized professional contractors for their cleaning. The places that need special attention when cleaning are shown in Figure 15.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
23
Figure 15: Places that need to be cleaned at least twice a year
7.3. SPECIAL MAINTENANCE
Your stove is a heat generator that uses pellets as solid biofuel. This is why you should do special maintenance once a year.
This is best done at the beginning of the heating season.
The purpose of the special maintenance is to ensure proper and efficient operation of the stove.
8. IMPORTANT SAFETY INFORMATION
You have purchased a product of the highest quality.
The manufacturer is always at your service to provide you with all the information you may need regarding the stove and instructions for assembly and installation in your geographical conditions. Properly connecting the stove, according to these instructions, is very important to prevent the danger of fire and any defects.
The stove works with a combustion suction pressure. Therefore, make sure that the smoke is well thermally insulated.
DANGER !
In case of fire in the smoke exhaust pipe take all the people and pets out of the room, unplug the power supply using the power switch in the house or remove the plug from the wall (plug must always be easily accessible and free of obstacles), and immediately call the fire department.
DANGER !
You cannot use conventional firewood.
Places that need to be cleaned at least
twice a year.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
24
DANGER !
Do not use the stove to burn waste.
9. THE PELLET QUALITY IS VERY IMPORTANT
This stove uses pressed wood (pellet) as fuel.
As there are many products like this on the market it is important that you select pellets as fuel that is not dirty. Make sure you use high quality pellets that are compact and with a little bit of dust.
Ask your sales representative or the manufacturer for the best pellet, with a diameter of 6 - 7 mm, the longest side 30 mm. Proper operation of the stove depends on the type and quality of pellets, since the heat obtained from different types of pellets can be of varying intensity.
When the pellet is poor quality the stove will have to be cleaned more often.
Manufacturer of the stove does not bear any responsibility for poor performance of the stove in case of use of the pellets of inappropriate quality.
9.1. STORING THE PELLET
The pellets must be kept in a dry place that is not very cold. Cold and moist pellets (at the temperature of around 50C) reduce the thermal power of the fuel and require additional cleaning of the stove.
THE PELLETS MUST NOT BE KEPT CLOSE TO THE STOVE. Keep them at least 2m away from the
stove. Handle the pellets carefully and do not break them.
WARNING: If the fuel tank is filled with sawdust or small (decomposed) pellets, it can prevent the insertion of the pellets. Such pellets can lead to burning the electric motor that drives the mechanism for the insertion of pellets, or damage the gear that works in conjunction with this electric motor. If the bottom of the pellets reservoir, or, at the bottom of the gear unit when the tank is empty you see such a pellet, suck it up with a vacuum by swiping the tube through open grates of the pellets.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
25
10. CONNECTING THE HYDRAULIC INSTALLATIONS
IMPORTANT:
Connecting the stove on a hydraulic installation can be done exclusively by qualified technicians, who can do this in accordance with applicable regulations of the country in which the installation is done.
GORENJE disclaims all liability in case of a material or bodily harm, in the event of failure, poor functioning, if the above recommendations are not followed.
The stove is designed for central heating.
The stove is prepared for a closed heating system. Follow the SRPS guidelines.
The back of the boiler with the connectors is given in Figure 16.
1. The Dino Stove
2. Chimney connector
3. Distribution pipe
4. Expansion container (in the stove)
5. Safety valve (in the stove)
6. Radiator valve
7. Radiator
8. Breather valve
9. Circulation pump (in the stove)
10. Return pipe
11. Charging and discharging tap (in the oven)
12. Thermo hydrometer
13. Drain pipe from the safety valve
14. The feeding tube of the air to be combusted
15. Boiler
STOVE-BACK
SIDE
BOILER
SCHEME OF HIDRAULYC INSTALLATION
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
26
Figure 16
11. PRESSURE AND RETURN PIPE
Outputs of the pressure and return pipes on the boiler are 1'' and you cannot reduce them or taper to the first bifurcation. Use a 1’’ steel pipe or a copper pipe with the outside diameter of Ø28mm or greater.
When installing, strictly observe the slopes of pipes as they need to be at 0.5% (5mm. per meter of pipe) and the venting system (boiler, pipes, radiators).
Set up a thermo hydrometer at the pressure line to show the water pressure in the system and the water temperature at the back end of the boiler.
12. BUILT-IN COMPONENT OF THE STOVE
- In the stove, there are the following built-in components:
- Safety valve
- Circulation pump
- Automatic air valve
- Expansion container and
- Charging and discharging tap
For this reason there is no need to install these components again. The stove is complete, which is a great advantage most all of because there is no need for additional space for the listed components.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
27
12.1. SAFETY VALVE
It is set up under the lid of the stove on the pressure line. Input connection is R1/2". It opens with water pressure of 2.5 bar. You can get to it by removing the right lateral side, when you are looking at the stove.
The output safety valves whose connection protrudes through the rear wall above the pressure line should be put into the sewer pipes.
12.2. CIRCULATION PUMP
A high-quality Wilo RS 25/6 – circulation pump has been built into the stove on the return line of R1”. The power of the pump is 93W. It is turned on and off by the electronics by the set water temperature.
The pump shaft has to be in a horizontal position. For this reasons, when connecting with the installation make sure that the pump does not turn around! Firmly hold galvanized bolt at the end of the back side.
You can reach the pump by removing the left lateral side, when you are looking at the stove.
Note:
If the stove and the pump have been idle for a long time (a month, for example), the pipe shaft can stick to the base, it may not move the water, or it can burn out. If when starting the stove when the water in the boiler heats up the water pump does not start, if the radiators do not heat up when the set temperature is reached, if you do not hear the murmur of water (moving), or if the boiler temperature rises and radiators are not warming, remove the left lateral side as indicated in the previous paragraph, and get to the pump. Put a cloth under the pump and using a flat screw driver with the tip width of 5 - 7mm, unscrew the short screw from the front of the pump. There will be a little bit of water coming from the pump, which is normal. Push the screw driver into the opening of the pump, reach the groove of the pump shaft and rotating the screwdriver and the shaft to the right and left break in the pump shaft. Put the pump screw back in its place into the opening of the pump and tighten it. Make sure that the rubber from under the screw does not come out.
12.3. AUTOMATIC AIR VALVE
There is an automatic air valve on the pressure line under the lid. It is suppose to drain the air out from the boiler.
You can get to it by removing the right lateral side, when you are looking at the stove.
The cap valve must be loose, not tight, so that the air can come out of the boiler and installations smoothly.
12.4. EXPANSION VESSEL
There is an expansion vessel built into the stove with a volume of 10 litres. Its function is to stabilize the pressure in the boiler and in the heating installation. The factory set pressure in the vessel is 1 bar.
12.5. CHARGING AND DISCHARGING TAP
As its name says, this is a charging and discharging tap.
It is located in the back side, down.
The input connection is a R1/2”, while the output has an extension for the hose.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
28
13. INSTALLING AND IGNITING Before the combustion starts entire system of central heating should be water-filled, well-vented, and the stove properly connected to the chimney, as discussed in previous counts.
Recommended operating pressure of water is 1 to 1.9 bar. Best to be within the limits of 1.2 to 1.6 bar.
The test pressure can be up to 1.9 bar.
NOTE:
The stove must not be used without water. It must be tied to the installation to which the consumers are connected (radiators) with minimum power of 8 kW.
14. PRACTICAL INSTRUCTIONS AND TIPS FOR THE USE OF THE HEATING SYSTEM
-All connections must be well sealed and fastened. There must be no leakage of water.
-Before you turn the stove on for the first time, the complete installation shall be tested with water at a maximum pressure of 1.9 bar.
-It is preferred that the water be at least once released out of the system due to the dirt which is located in the system.
-Make sure that all valves between the stove and the installation are open.
-Make sure that all the air from the boiler and installation is released before placing the boiler in operation. For this reason, the installation should be filled with water slowly so that the air manages to get out of the installation.
-During the ignition and cooling phase, the stove can expand and contract, and at the same time you can hear little crackling. This is absolutely normal, because the structure is made of steel and this certainly can not be regarded as a disadvantage.
Basic programming that is done in the factory guarantees proper operation and prevents overheating problems when you first turn on the stove, and for later as well.
15. FILLING WITH WOODEN GRANULES
Refuelling is done on the upper side of the stove by opening the lid. Put the wooden granules in the tank. Its load capacity when it is empty is about three 15 kg bags, a total of 45kg of pellets.
To simplify the procedure, do this in two stages:
-Put half a bag into the tank and wait until the pellets reach the bottom. Turn the stove on. -When the stove starts to work normally put the pellets as needed in the storage for pellets. -Do not ever remove the security grid from the tank. When putting the wooden granules in, prevent the bag from coming into contact with hot surfaces.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
29
16. DESCRIPTION AND MODE OF OPERATION OF THE CONTROL SYSTEM
16.1. DESCRIPTION OF THE PUSH BUTTON DISPLAY
Pointers Function
Upper pointer shows the status of the stove, the selected menu, the
operation doze indicator, and the operation of the time-control
indicator program.
Lower pointer shows the current time, the value of the settings and
the parameter, as well as the names and warnings.
lighter indicator
circuit pump indicator
Display
Button to adjust -
Display
ON/OFF push button
Button to adjust +
MENU button
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
30
dosing indicator
The display when the stove is running in the combustion stage
Upper pointer: The upper display alternately shows: BURN, and then P5D5 , with Px actual current running force, and DX adjusted running force.
Lower pointer:
The lower display alternately shows:
The temperature of the flue gases: 155
The boiler water temperature: B72
Boiling water return line: r45
The display when the boiler is OFF
Upper pointer: OFF
Lower pointer:
Clock: 6:35 PM
Push button Function
ON/OFF push button
Long press the on/off switches of the stove
Short pressing brings you back to the initial display.
Push button +
Pressing while the stove is running increases the set power.
With the last pressing of the MENU button, this push-button increases the desired room temperature.
By pressing the menu we select a submenu.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
31
Push button -
Pressing while the stove is running decreases the set power.
With the last pressing of the MENU button, this push-button decreases the desired room temperature.
By pressing the menu we select a submenu.
MENU button
By briefly pressing the home screen, the display will show the set value for the room temperature that can be adjusted by pressing the + and -.
Pressing for more than 2 seconds will activate the display menu.
Pressing for more than 4 seconds will activate the advanced settings of the menu. By continuing to press this button we will see all menu options one after the other.
For the choice of the parameter in the submenu we use the + and - buttons. By pressing the MENU button again we activate the flashing of the set parameter values, which can be adjusted by pressing the + and -.
Briefly press the ON/OFF button to return to the initial display.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
32
Figure 12
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
33
16.2. WHEN THE BOILER IS ON
The display shows the current phase of the mode of operation (for example TestFire, HeatUp, etc.) and alternately on the upper display shows every 5 seconds the set and the actual capacity of the boiler.
By pressing the + button you will increase the power of the stove, while by pressing the - button you will
decrease it.
By pressing the MENU button again you activate the flashing of the set parameter values, which can be adjusted by pressing the + and - buttons.
The stove works with the preset power until the room temperature reaches the modulation threshold or until flue gases reach their limit values. In the first case the regulation of H2O is shown, while in the second case the Gas regulation is shown.
In the event of a short power interruption (up to 2 minutes) after the power is restored, the stove continues to operate in a manner as before the power failure. If the interruption is prolonged, the stove automatically executes the safety shut-off and cooling so you should turn it back on.
16.3. TURNING THE BOILER OFF
Pressing the ON/OFF button for longer than about half a second while the stove is running the display shows ON and OFF. Once the button is released, the stove begins the process of turning off. The screw conveyor stops, STOP FIRE shows on the display, fans operate at maximum speed to clean the firebox. Once the combustion chamber is cooled down to the appropriate temperature, the stove shuts down and goes into sleep mode. The display will read OFF.
TURNING THE BOILER ON
Pressing the ON/OFF button for longer than about half a second while the stove is not running the display shows ON and OFF. Once the button is released, the stove begins the process of turning on. The display reads TESTFIRE, fans are working at full speed to clean the combustion chamber, screw conveyor is not moving, the lighter is heated. After that, if the temperature of the stove is low, it will start the process of HEATING UP in which the pellets are quickly dispensed and the fans rest. After that the procedures Fuel IGNI and TEST IGNI are started while the boiler reaches the conditions for transition to the (BURN) burning
phase.
Pressing the MENU button for 2 seconds (after you let go of the button tH20 is displayed) the current room temperature is displayed. Press the + or - to choose other temperature and fan display status.
ATTENTION
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
34
16.4. SETTING UP THE TIME-CONTROLLED PROGRAM
Long pressing (until TIMER is shown) on the MENU button opens a menu time-controlled program.
Select ON or OFF to include or exclude the time-controlled program. It is necessary to set up the exact time and day of the week (1 is Monday ... 7 is Sunday) and then program 6 programming periods and temperatures.
Each of the 6 time periods is limited to the initial (P1a - Program 1 onset) and final time (P1d - Program 1 offset). Within this period, the stove is turned on and working to maintain the room temperature that was set up (P1t).
After that, for every day of the week we choose 3 time periods.
For example, for Tuesday the upper display shows DAY2, and the lower display shows P1, P3, and P6, which means that on Tuesday the boiler will work in periods programmed in programs P1, P3, and P6.
Figure 13: Time setting diagram
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
35
Figure 14: Showing the navigation through the menu timer
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
36
16.5. SIGNS AND MESSAGES ON THE DISPLAY
Signs on the pointers The meaning of the message and the status of the stove
OFF
1 2 :5 3
The stove is idle.
°OFF
1 2 :5 3
The stove is idle, but the time mode is activated, so that it turns on
automatically at the time that was set up.
TEST
FIRE
The stove checks whether there is adequate combustion and flame in the
combustion chamber. This process is activated after the power supply
interruption.
Hea t
UP
In the ignition stage, after the screw conveyor fills the firebox, the lighter
heats up the pellets to ignition.
Fuel
IGNI
After the Heat up phase the stove ignites the pellets. At this stage, there is
no dosage.
TST
IGNI
At the end of the ignition phase the lighter turns off the stove and examines
whether the ignition was successful, is the burning proper, and are the
temperatures increasing properly.
BURN
1 2 3 °
Burning phase (which is normally the working phase). Lower pointer shows
the temperature of the flue gases at the back end of the stove.
BURN
B78°
Burning phase, the lower display shows boiler water temperature.
BURN
R48°
Burning phase, the lower display shows the return line water temperature.
P5D5
R48°
The upper pointer shows the current power of the stove (Px) and the set up
power of the stove (Dx).
CLN
FIRE
Cleaning phase. The fan blows the ash and other debris from the firebox.
This phase occasionally runs automatically in the burning phase.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
37
FIRE
STOP
The stove is in the process of stopping and cooling.
COOL
FLUID
When even with the minimal force the room temperature reaches a certain
;level, the level the stove goes into the COOL AIR phase and begins to cool down. The
stove is astove is automatically switched on again after the room temperature falls
below a cto a certain value.
ALAR
PEL
In the burning phase there are pellets missing.
ALAR
FIRE
Ignition failed. Check the condition of the stove, clean the firebox, and try
igniting the stove again.
ALAR
SEC
The safety thermostat reacted. Check the condition of the stove, and if you
do not see any obstacles, manually reactivate the safety thermostat and
turn the stove back on. Otherwise, contact the service center.
ALAR
PRES
The safety thermostat reacted. Check the condition of the stove, and if you
do not see any obstacles, manually reactivate the safety thermostat and
turn the stove back on. Otherwise, contact the service center.
ALAR
TC1
No signal from the transducer flue gases. Contact the service center.
ALAR
TCh
No signal from the temperature firebox. Contact the service center.
ALAR
AIr
No signal from the flow, or the fans are not working properly. Contact the
service center.
ALAR
drtY
It is necessary to clean the stove and/or chimney.
ALAR
NTC
No signal from the temperature firebox. Contact the service center.
ALAR
GASS
The temperature of the flue gases is too high.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
38
16.6. ELECTRICITY SCHEME
Figure 15 Electricity scheme
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
39
16.7. MENUS
If you press and hold the MENU button the menus will show one after the other. To select the menu you need to let go of the button when you see the respective menu. The descriptions of the menus are listed
below.
Figure 16: Menu description
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
40
16.8. ALARMING SITUATION
service
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
41
service
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
42
service
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
43
service
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
44
service
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
45
service
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
46
service
service
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
47
17. SAFETY MEASURES
The stove is equipped with the following safety devices:
- PRESSURE REGULATOR
Checks the pressure in the chimney. It stops the spiral conveyor of the pellets when the drain is clogged or when there is pressure (wind).
- FLUE GASES TEMPERATURE SENSOR
Checks the temperature of flue gases that allow the stove to be turned ON or stop the ignition if the flue gas temperature drops down below the programmed value.
- CONTACT THERMOSTAT ON THE SNAIL BASE
When the temperature goes over the set safety value the stove will turn off immediately.
- BOILER CONTACT THERMOSTAT
When the temperature goes over the set safety value the stove will turn off immediately.
- WATER TEMPERATURE SENSOR
When the water temperature comes close to the stop-temperature (80 ° C) the sensor triggers the stove to do a series of cooling cycles or turns the stove off automatically using the ECO-STOP in order to prevent blocking of the above-described capillary temperature sensor.
service
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
48
- ELECTRIC SAFETY
The stove is protected from high current disturbances using standard fuses that are located in the main switch on the back side of the stove and on the control panel - the motherboard.
- FLUE GASES FAN
If the fan stops, the motherboard immediately blocks the supply of pellets and an alarm signal will show.
- GEAR MOTOR
When the gear motor stops working, the stove keeps on working until the flame, due to the lack of oxygen, goes out and until the stove reaches the minimal cooling level.
- INTERRUPTION OF ELECTRICITY
If there is a short interruption of electricity the stove automatically starts to cool down.
- NO IGNITION
If there is no flame when you turn the stove on the stove goes into an alarming state.
18. FAILURES - CAUSES – SOLUTIONS
PROBLEMS POSSIBLE CAUSES SOLUTIONS
Wooden granules are not put into the firebox, in the combustion chamber.
1. The wooden granules tank is empty.
2. The infinity spiral is blocked.
3. The gear motor of the infinity spiral is defective.
4. Electronic card is defective.
1. Fill the tank
2. Empty the tank and unblock the spiral - snail
3. Change the gear motor
4. Change the electronic card
The flame is out or the stove turns off automatically.
1. The wooden granules tank is empty.
2. The combustion chamber is not supplied with the wooden granules.
3. Safety probe intervention for the wooden granules temperature.
1. Fill the tank with wooden granules.
2. See last instruction.
3. Let the stove cool off completely and turn in back on again. If the problem persists call technical support.
4.Close the door or change the glass sealing with original sealing.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
49
4. The doors are not closed properly or the glass sealing is worn out.
5. Inadequate wooden granules.
6. Poor supply of wooden granules.
7. The combustion chamber is empty.
8. The chimney is clogged.
9. Interference of failure of the pressure switch.
10. The smoke vacuum motor is defective.
5. Change the type of the wooden granules and pick the type that is approved by the manufacturer.
6. Check the dosage and settings.
7.Clean the combustion chamber as instructed in the manual.
8. Clean the smoke channel.
9. Change the pressure switch.
10. Check the motor and change if needed.
It worked for a couple of minutes but then it turned off.
1. The ignition phase is not over.
2. Check if there is an electricity interruption.
3. The smoke channel is clogged.
4. Interference of failure of the pressure switch.
5. The spark plug is damaged.
1. Try igniting again.
2. See last instruction.
3. The smoke channel is clogged.
4. Check or change the probe.
5. Check or change the spark plug.
Wooden granules are settling in the combustion chamber.
The glass on the door is dirty and the flame is weak.
1. Lack of air for combustion.
2. Wet or inadequate wooden granules.
3. The smoke vacuum system motor is defective.
1. Clean the combustion chamber and check if all the openings are clear. Do the standard cleaning of the combustion chamber and the smoke channel. Check if air flow is clogged. Check the gaskets on the door.
2. Change the type of the wooden granules.
3. Check the motor and change if needed.
The smoke vacuum motor is defective.
1. The stove is not receiving the electricity.
2. The motor is defective.
3. Motherboard is defective.
4. The control panel is defective.
1. Check the main power supply and resistance to melting.
2. Check the motor and condenser; change if needed.
3. Change the electronic card.
4. Change the control panel.
In automatic mode the stove works at maximum
1. The thermostat is programmed to the maximum position.
1. Set the thermostat temperature again.
2. Change the probe position.
3. Check the probe and change if needed.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
50
capacity all the time.
2. The thermostat for outside air always checks the cool air.
3. The probe that checks the temperature is defective.
4. The control panel is defective or not working.
4. Check the control panel and change if
needed.
The stove does not turn on
1. Check if there is an electricity interruption.
2. The wooden granules probe is blocked.
3. The pressure switch is not working (says it is blocked).
4. The smoke vacuum or smoke supply channel is clogged.
1. Make sure the plug is in and check if the main switch is in I position.
2. Unblock the probe by checking the thermostat in the back. If it blocks again change the thermostat.
3. Change the pressure switch.
4. Clean the smoke channel.
Table 8.
19. INFORMATION ON DISPOSING (THROWING AWAY) AND DISMANTLING (PULLING APART) OF THE STOVE
Dismantling and throwing away, or disposing of an old used stove is the sole responsibility of the owner.
The owner of the stove must abide by the regulations in his/her country related to the safety and environment protection. Dismantling and disposing of the stove may be left to a third party to do if the third party is a company authorized to collect and dispose of such materials.
NOTICE: In all cases you must abide by the applicable regulations of the country where the stove is installed regarding disposal of such materials (things) and, if necessary, report the disposal of such items.
ATTENTION
Dismantling the stove must be done only when the chamber of the stove is not working and when the stove is unplugged from power (no power supply).
• pull out all electric parts,
• throw away the batteries and electronic cards of the remote control in the proper garbage cans in accordance with the standards.
• separate the batteries you are keeping from the electric cards,
• dismantle the stove with the help from an authorized company
ATTENTION
Disposing of the stove in public places poses a serious risk for people and animals. In such cases it is always the responsibility of the owner if a person or an animal gets hurt.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
51
When the stove is dismantled, this manual and all other documents related to the stove must be destroyed.
20. THE DURATION OF GUARANTEED SERVICE
By this we mean the time in which we guarantee service, accessories, and spare parts, starting from the date of purchase of the appliances.
The time of the guaranteed service is in accordance with the legislation.
In case of a change of the model and design of the appliance, the deadline for replacing the parts for which the design has been changed is within the legal deadline.
After this period the affected parts are provided in the new designs.
20.1. WARRANTY TERMS AND CONDITIONS
Product warranty is valid within the legally defined deadline.
The warranty does not apply to the glass or to the physical damage caused after purchase.
THE MANUFACTURER RESERVES ALL RIGHTS TO CHANGES.
The appliance will, within the warranty period, only function correctly when used in accordance with the instructions for connection and use.
The warranty ceases to be valid if it is determined that:
- Connecting the product or repair was performed by unauthorized persons, or if they built in counterfeit parts,
- If the appliance is not properly used in accordance with this instructions manual,
- If during use there was mechanical damage to the appliance,
- If the fault repair was done by unauthorized persons,
- If the appliance was used for commercial purposes,
- If the damage occurred during transportation after selling the appliance,
- If the failure was due to improper installation, improper maintenance, or mechanical damage caused by the customer,
- If the malfunction was due to too much or too low voltage as well as due to force majeure.
Malfunctions of the appliance can be removed outside the warranty period with original spare parts that we also give a warranty for under the same terms and conditions.
This warranty does not exclude or affect the rights of consumers in connection with the goods in accordance with legal provisions. If the delivered product does not match the contract, the consumer has the right to require the seller to fix this by repairing or replacing the product in accordance with legislation that is in effect.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015
52
__________
PELLET BOILER
ECOLOGIC 30
Instructions for use, maintenance and installation
June 2015
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
2
We thank you for your purchase of Gorenje pellet boiler. We ask to thoroughly read instructions for
use before installing and using your pellet boiler ECOLOGIC 30. Heating appliances (in the
following: "pellet boiler" or "boiler") of company Gorenje d.d. (in the following: Gorenje) are
manufactured and tested in accordance with safety requirements of European Directives in force.
These instructions are intended for end users, installers and authorized maintenance personnel for
Gorenje pellet boilers. If you have any doubts regarding the instructions for use or require any
clarification, please contact the manufacturer or authorized person of company Gorenje d.d.
directly.
Printing, translation or reproduction, even in part, of the instructions of use is possible only upon
approval by company Gorenje d.d..
You have purchased a Gorenje boiler, which is used for central heating of surfaces from 80 m2 to 400
m2. The fuel for the boiler is wood pellets. The boiler operates automatically by dosing pellets with a
dosing screw from pellet container, which is a component part of device and is installed above the
boiler part of the device. The container is filled with pellets from above, through the provided cover.
Ensure that the incineration device is correctly dimensioned according to heating system and thermal
requirements of the building. Connection and start-up of the machine must be done by an authorized
person.
Flame, produced with correct burning of wood biomass inside the boiler, emits the same amount of
carbon dioxide (CO2) as with normal decomposition of wood.
The amount of CO2 produced by the combustion or decomposition of wood corresponds to the
amount of CO2 that a tree obtains from the environment and then transforms to oxygen and carbon.
The use of non-renewable fossil fuels (coal, fuel oil, gas), as opposed to what happens with wood, re-
leases into the air enormous amount of CO2 accumulated over millions of years, which increases the
greenhouse effect. The principle of clean combustion fully meets all environmental requirements,
and ECOLOGIC 30 has based its entire development on this basis.
Last revision of instructions: June 2015
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
3
INDEX
1. PURPOSE OF INSTRUCTIONS FOR USE ..................................................................... 5
1.1. UPDATES .................................................................................................................................. 5
2. RESPONSIBILITY OF MANUFACTURER ...................................................................... 5
2.1. BASIC PREVENTIVELY REQUIRED STANDARDS ......................................................................... 5
2.2. TRANSPORTATION AND HANDLING OF PELLET BOILER ........................................................... 6
2.3. RESPONSIBILITY OF INSTALLER ................................................................................................ 6
3. INSTALLATION ......................................................................................................... 7
3.1. PLACEMENT ............................................................................................................................. 7
3.2. EXTRACTION OF SMOKE GASES ............................................................................................. 10
3.3. INSULATION AND DIAMETER OF HOLES IN THE ROOF .......................................................... 12
3.4. INLET AIR ............................................................................................................................... 13
3.5. ELECTRICAL CONNECTION ..................................................................................................... 13
4. BOILER COMMISSIONING ..................................................................................... 15
5. SAFETY WARNINGS ............................................................................................... 15
5.1. SAFETY WARNINGS FOR MAINTENANCE STAFF .................................................................... 15
5.2. SAFETY WARNINGS FOR USER ............................................................................................... 16
6. INSTRUCTIONS FOR SAFE IGNITION AND CLEANING OF BOILER ............................. 17
6.1. REGULAR MAINTENANCE AND CLEANING OF BOILER .......................................................... 17
6.2. CONTROL AND PARTS REQUIRING MAINTENANCE ............................................................... 19
6.3. ADDITIONAL MAINTENANCE ................................................................................................. 20
7. IMPORTANT SAFETY INFORMATION ...................................................................... 20
8. PELLET QUALITY IS VERY IMPORTANT .................................................................... 21
8.1. STORING PELLETS .................................................................................................................. 22
9. DESCRIPTION AND OPERATION OF CONTROL DEVICE ............................................ 23
9.1. BOILER DURING OPERATION ................................................................................................. 26
9.2. BOILER SHUTDOWN .............................................................................................................. 26
9.3. BOILER ACTIVATION ............................................................................................................... 26
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
4
9.4. TIME PROGRAMME SETTING ................................................................................................ 27
9.5. INDICATIONS AND MESSAGES ON DISPLAY ........................................................................... 28
10. MENU ................................................................................................................... 30
11. ALARM STATUSES ................................................................................................. 32
12. INFORMATION REGARDING DESTRUCTION AND DISPOSAL OF BOILER ................... 39
13. WARRANTY CONDITIONS ...................................................................................... 39
14. TECHNICAL CHARACTERISTICS OF MODEL ECOLOGIC 30 ........................................ 42
15. DIMENSIONS OF BOILER ECOLOGIC 30 .................................................................. 43
Instructions for installers ................................................................................................. 44
1. Boiler room .......................................................................................................... 45
2. Boiler parts ........................................................................................................... 46
3. Boiler connection instructions............................................................................... 48
4. CONNECTION SCHEMES ........................................................................................ 51
4.1. SCHEME NR.1: HEATING ONLY ............................................................................................... 51
4.2. SCHEME NR.2: HEATING + HOUSEHOLD HOT WATER ........................................................... 53
4.3. SCHEME NR.3: HEATING WITH MULTIPLE SYSTEMS .............................................................. 55
Instructions for first start-up…………………………………………….…………….................................59
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
5
1. PURPOSE OF INSTRUCTIONS FOR USE
The purpose of instructions for use is that the user takes all necessary measures and prepares all
required equipment to ensure safe and proper use of combustion device.
1.1. UPDATES
These instructions reflect the state of the product at the moment the boiler is produced.
Instructions are not applicable for products, which are already present on the market with corre-
sponding technical documentation and cannot be considered as insufficient or inadequate after any
modification, adaptation or application of new technologies on newer products.
The content of this booklet must be carefully read and heeded to. All of the information, contained in
this booklet, is necessary for correct installation, use and maintenance of you boiler.
The instructions must be stored carefully and safely. Instructions for use, maintenance and
installation are a component part of pellet boiler.
If the pellet boiler changes ownership to another person, this person must also receive these
instructions for use, together with the boiler.
If the instructions get lost, request for a new copy of instructions from the manufacturer, authorized
reseller or repairman.
2. RESPONSIBILITY OF MANUFACTURER
In providing these instructions, Gorenje d.d. rejects any civil or penal liability, direct or indirect, due to:
accidents caused by non-compliance with standards and specifications from these instructions;
accidents caused by prohibited or incorrect use by the user;
accidents caused by modifications and repairs not authorized by manufacturer Gorenje d.d.;
poor maintenance;
unforeseeable events;
accidents caused by use of non-original or improper spare parts.
The installer is fully responsible for installation.
2.1. BASIC PREVENTIVELY REQUIRED STANDARDS
Product ECOLOGIC 30 is manufactured in accordance with the following standards:
DIRECTIVE EC ON MACHINERY (2006/42/EC); DIRECTIVE EC ON LOW-VOLTAGE EQUIPMENT (2006/95/EC); DIRECTIVE EC ON ELECTROMAGNETIC COMPATIBILITY (2004/108/EC); DIRECTIVE EC ON BOILERS FOR HEATING ON SOLID FUELS UP TO NOMINAL POWER kW; EN 303-5 Harmonized standards:
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
6
SIST EN ISO 12100-1: 2004 and A1: 2010;
SIST EN ISO 12100-2: 2004 and A1: 2010;
SIST EN 303-5: 2012;
61000-6-3: 2007;
61000-6-2: 2005;
61000-3-3: A1 2002;
61000-3-3: A2 2006;
EN 60204-1: 2006 and A1:2009.
2.2. TRANSPORTATION AND HANDLING OF PELLET BOILER
When moving the boiler, pay attention to your safety.
Before transport and handling of the boiler, which must be performed in complete safety, make sure
that the lifting capacity of transport equipment suffices. Avoid sudden and/or abrupt movement of
boiler.
ATTENTION
DISCARD ALL PACKAGING OUT OF REACH OF CHILDREN. DANGER OF SUFFOCATION WITH
BAG, FOIL, POLYSTYRENE ETC.
2.3. RESPONSIBILITY OF INSTALLER
It is the responsibility of the installer to check adequacy of installation and pipeline, ensure air intake
for combustion, ensures regulated distances and all other solutions, required for installation of the
pellet boiler.
It is the responsibility of the installer to ensure compliance with local legislation in force in the place
of pellet boiler installation.
Use of the pellet boiler must conform with instructions, provided in Instructions for use, maintenance
and installation, and all safety standards, specified by local legislation in the place of pellet boiler
installation.
Standard UNI 10683 defines duties of installer. The installer must check:
type of device to be installed;
adequacy of space for installation of unit, reflected by minimum required size of the space, in which the pellet boiler will be installed;
instructions of the manufacturer about heating device, regarding requirements of smoke
gases outlet;
flue pipe internal diameter, the material it is made of, is it straight or even and that there are
no obstructions;
height and, if required, vertical extension of flue pipe;
existence and suitability of flue pipe cover resistance;
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
7
possibility of outside air intake;
possibility of simultaneous use of generator for connection with other equipment.
If the results of all above provided checks are positive, installation may proceed. Carefully heed to
instructions provided by the manufacturer, as well as safety and fire prevention standards in force.
After the first start-up of the boiler, perform a minimum 30-minute test of operation to check all
required demands.
When the installation is complete, the installer must provide the customer with the following:
instructions for use, maintenance and installation from the manufacturer (if not included in
the unit);
required documentation in accordance with standards in force;
perform training of customer for operation and regular maintenance and cleaning of the
device.
3. INSTALLATION
Responsibility for installation work in the space is entirely upon the customer.
Before proceeding with installation, the installer must comply with all required legal safety standards,
especially:
Check that norms regarding pellet boiler installation meet local, national and European
norms
Heed to requirements set forth in this document
Check that pipes and air intake are compliant with the type of installation
Do not make temporary electrical connections by using unsuitable cables
Check earthing of electrical system
Always use individual safety equipment and all legally required protection
Always allow sufficient space for maintenance work
Acquire consent of chimney sweep for connection of boiler to flue
Perform measurement of smoke gases outlet after finished installation.
3.1. PLACEMENT
It is advisable to remove pellet boiler packaging only when it is in the place of installation.
If the adjacent walls and/or flooring are made of material that is not heat resistant, suitable
protection must be provided using insulating, non-combustible material.
For protection of flooring, made of flammable material, we advise installing a metal plate with
thickness 3 to 4 mm under the boiler, which protrudes at least 30 cm out from the front of the pellet
boiler.
Pellet boiler must be installed in accordance with drawing that defines distances from walls (figure 1).
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
8
Figure 1: Minimum distance of boiler from boiler room walls
Flue pipe
EXAMPLE 1
EXAMPLE 2
Flue pipe
Flue pipe
EXAMPLE 3
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
9
If the pellet boiler is installed in a boiler room, where there are other devices, which drain air (other
boiler, various suction fans etc.), make sure that the volume of air intake is sufficient for safe
operation of combustion device.
If the smoke duct passes through a ceiling, it must be properly insulated using diaphragm of non-
combustible insulation material.
When the pellet boiler is placed, it must be levelled with support feet (horizontal positioning).
ATTENTION
Smoke gas discharge MUST NOT BE CONNECTED TO:
Flue pipe, used by other combustion devices (boilers, stoves, fireplaces etc.);
Air extraction systems (hoods, air extraction fans etc.).
ATTENTION
Installation of draught closing valves is prohibited! Flue connection Ø 80 mm from pellet boiler to flue pipe should be:
no more than 5 m long (in case of longer connection, dimension of connection pipe must increase to Ø 130 mm);
each 90° joint requires a 1 m shorter flue connection;
each joint must be fitted with doors for cleaning;
connections between pipes must be sealed.
ATTENTION
If there is too much resistance in extraction system (many joints, improper end fitting, bottlenecks etc.), extraction of smoke gases is not provided for. Therefore, connection pipes and joints must be increased to a greater dimension – Ø 130 mm. If the flue does not ensure appropriate extraction of smoke gases, it can also come do improper operation and, consequently, to alarm from boiler ECOLOGIC 30. It is advisable that the flue is inspected by an expert before installing boiler ECOLOGIC 30.
Smoke gases extraction system from pellet boiler functions on the basis of negative pressure in the
boiler and barely perceivable pressure in flue connection pipe Ø 80 mm. It is very important that the
smoke gases extraction is sealed.
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
10
Layout and structure of the space, where the flue is installed, needs to be analyzed. If it passes
through walls and/or roof, it must be properly installed in accordance with fire prevention safety
standards.
Ensure that there is enough air for proper combustion in the space, where the pellet boiler is
installed. If boiler ECOLOGIC 30 lacks oxygen/air, the boiler displays an alarm. External supply or
intake of external air requires a pipe with a diameter of at least 110 mm with maximum length of 10
m. Each 90° joint requires a deduction of 1 m in line length. If the air supply is longer, diameter of air
intake pipe must be increased.
In case of a grid on the facade, draught opening must be 100 cm² or larger.
The device operates at 220 V – 50 Hz. Make sure that the electrical cables are not laid under the
boiler, that they are far away from hot surfaces and that they do not touch sharp parts, which could
damage them. If the pellet boiler is under electrical overload, life expectancy of electrical component
greatly reduces.
ATTENTION
Never turn off the boiler by pulling the electrical cable from the socket, while fire is still
burning in the boiler. This could damage the boiler and seriously jeopardize its functioning.
3.2. EXTRACTION OF SMOKE GASES
Extraction of smoke gases must be in accordance with regulations in force. Pipes for smoke gases
must not be connected to other discharge pipes of any other combustion device (figure 2). It is
prohibited to set up extraction of smoke gases into closed and/or semi-closed spaces, e.g. garage,
narrow passages or hallways, underpasses or any other similar spaces. If the flue connection is not
suitable, it must be implemented in accordance with previously provided requirements (point 3.1).
Figure 2
YES NO
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
11
ATTENTION
Extraction of smoke gases must be earthed in accordance with regulations in force. (Earthing
connection is required by law).
Earthing must be independent of combustion unit.
Regarding dimensions and material, from which it is made, the flue pipe must conform to standards
UNI 9615-9731, UNI 10683 - EN1856-1.
Flue pipes in poor condition and/or made of unsuitable materials (asbestos, zinced sheet metal etc.,
with rough or porous surfaces) are prohibited by law and compromise proper boiler operation.
Smoke can be extracted through a traditional flue pipe (see figure below) provided that the following
rules are met:
Check condition of flue pipe maintenance. For proper maintenance and/or restoration
contact chimney sweep service.
Extraction of smoke gases can be connected directly to flue pipe only if it has a maximum
dimension of 20 x 20 cm or diameter of 20 cm and is fitted with inspection hole.
If the flue pipe is of greater dimensions, a stainless pipe (with required diameter) with proper
insulation must be installed into it.
Make sure that the connection with the flue pipe is properly sealed.
Avoid contact with flammable material (such as wood ashes), and, in any case, insulate them
with fire-resistant material.
When using connections between the pellet boiler and flue pipe, it is mandatory to use joints with
cleaning doors (figure 3). Use of joints with cleaning doors enables regular cleaning without the need
to disassemble pipes. Exhaust fumes in flue connection are under slight pressure. Therefore, it is
compulsory to check that the cover for cleaning ash is completely hermetically closed and that it
remains in this state after each cleaning. Ensure proper reassembly and check condition of the seal.
Figure 3: Cleaning unit
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
12
Connection between pipes must be always made with male fitting turned upwards (figure 4).
It is advisable to avoid using horizontal connections of pipes to flue. If this is not possible, the pipes
must not be installed in a downwards angle, but at an upwards angle of at least 5 % (figure 5).
Horizontal installation of pipes must not exceed 2 m in length.
It is not advisable to connect the pipe from the pellet boiler directly to flue with horizontal pipe,
longer than 1 m.
Figure 4 Figure 5
3.3. INSULATION AND DIAMETER OF HOLES IN THE ROOF
Once the position of boiler installation is determined, a hole for passage of smoke pipes must be
made. This changes in regard to the type of installation, diameter of smoke pipes and type of wall or
roof, through which it must be guided. Insulation must be of mineral origin (rock wool) with nominal
density greater than 80 kg/m³.
Perfect draught depends mostly on flue pipe, which must be free of obstructions, such as bottlenecks
and/or various joint connections. Joint must be at an angle of 30°, 45° and 90°. Joints at an angle of
90° must be made of three parts (figure 6).
In any case, it is mandatory to provide an initial vertical straight pipe of 1,5 metres in length
(minimum) to ensure correct extraction of smoke gases.
Figure 6
NO YES 5 % or more
Direction of smoke
gases
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
13
3.4. INLET AIR
Air from the environment, required for correct combustion, must be refreshed with new air, through
opening in the wall, slot in boiler room doors or grid on the window. This will ensure proper
combustion and proper boiler operation.
Opening for intake of fresh air must also be fitted with protective slot against rain, wind and insects.
Hole must be made on the external wall of the space, where the pellet boiler is installed.
Standard UNI 10683 prohibits intake of inlet air from storage of flammable materials or spaces with
the risk of fire.
If there are other combustion devices in the room, a sufficient amount of air must be ensured, which
is required for proper combustion of all combustion devices, and regard all technical properties of
already installed ventilation systems in the boiler room.
Figure 7
3.5. ELECTRICAL CONNECTION
Combustion device requires connection to electrical network. Our pellet boilers are fitted with power
supply cable for medium temperatures. If the power supply cable is damaged and must be replaced,
contact our service staff.
Before making electrical connections, make sure that:
The characteristics of electrical wiring meet the data, given on the combustion device.
Extraction of smoke gases is earthed in accordance with regulations and local requirements
in force. (Earthing is required by law).
100 cm2 or more
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
14
Power supply cable must never reach 80 °C above ambient temperature. If you want to
connect the boiler directly to electrical network, you must install a bipolar switch with
minimum distance of 3 mm between contacts, suitable for required electrical voltage and in
accordance with regulations in force. Bipolar switch must always be accessible, even after the
boiler is installed.
Electrical connection
The pellet boiler must be connected to electrical network. Power supply cable is 3 m long, white and
designated with "220 V". Other connection cable is intended for connection of pump, is black and
designated with "Pump".
Figure 8
White – Boiler supply (220 V)
Black – Pump
If the power supply cable is damaged, it must be replaced. It can only be replaced by an authorized
person.
Electrical connection must be easily accessible even after the pellet boiler is installed.
ATTENTION
When the boiler installation is finished, it is mandatory to perform measurements of smoke gases discharge.
white cable
boiler supply
black cable
pump
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
15
4. BOILER COMMISSIONING
Boiler commissioning can be performed only by a manufacturer authorized technician, otherwise
the warranty is void.
INSTRUCTIONS FOR SAFETY OF PERSONS, ANIMALS AND PERSONAL PROPERTY
We wish to inform the installer on some general guidelines, which must be complied with for correct
installation of pellet boiler. These are required standards, but are not sufficient; for further and more
detailed information it is necessary to read the rest of the Instructions for use, maintenance and
installation.
Connect the pellet boiler to electrical network;
Do not allow children or animals in the boiler area;
Use only quality pellets and no other types of fuel;
Inform all users on possible risks and hazards, and educate them on handling the pellet
boiler;
If the pellet boiler is placed on a wooden floor, it is advisable to protect the floor in
accordance with regulations.
ATTENTION
The pellet boiler operates by creating negative pressure in the combustion chamber.
Therefore, ensure that the extraction of smoke gases is thermally sealed.
Upon first start-up (minimum operation of boiler – 1 hour), paint evaporates fumes, which
have unpleasant odour. Therefore, ventilate the room afterwards.
5. SAFETY WARNINGS
5.1. SAFETY WARNINGS FOR MAINTENANCE STAFF
Along with adhering to general safety regulations, maintenance staff must also:
Always use safety devices and individual safety equipment according to Directive
89/391/EEC;
Disconnect power supply before commencing any work;
Always use suitable tools;
Before commencing any work on the boiler, ensure that the boiler, as well as the ashes in it,
are cold, especially before touching it;
PELLET BOILER IS NOT TO BE CONSIDERED USABLE, IF EVEN ONE SAFETY DEVICE IS
MALFUNCTIONING, INCORRECTLY REPAIRED OR NOT FUNCTIONING!
Do not perform any modifications of any type for whatever reason other than those allowed
and/or approved by the manufacturer or authorized person.
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
16
Always use original spare parts. Do not wait for boiler components to wear out before
replacing them. Replacing a worn-out part, before it malfunctions, helps prevent injuries,
caused by sudden failure of a component, which can seriously jeopardize persons and/or
their property.
When cleaning ash, also clean the combustion container and space beneath it.
5.2. SAFETY WARNINGS FOR USER
Space, where the pellet boiler will be placed, or installation area, must be in accordance with local,
national and European directives.
The pellet boiler is a combustion device and external surfaces of the boiler can reach higher
temperatures during operation.
The pellet boiler is a C1 class boiler, produced exclusively for burning wood pellets (pellets of 6 mm in
diameter and 30 mm in length with maximum moisture content up to 10 %) or for fuel C1 (wood
pellets) in accordance with standard EN 14961-2.
ATTENTION
DURING PELLET BOILER OPERATION, CHILDREN ARE PROHIBITED TO COME NEAR OR PLAY
WITH IT!
When using a combustion device, it is advisable to take special care of the following:
during boiler operation DO NOT approach it and do not touch the doors of combustion
chamber, because of DANGER OF BURNS
during boiler operation DO NOT approach it and do not touch the flue connection, because of
DANGER OF BURNS
during boiler operation DO NOT perform any kind of cleaning on the combustion device
during boiler operation do not open the doors of the firebox, because it operates properly
only when its doors are hermetically sealed (if you open the doors during operation, an alarm
will sound)
during boiler operation DO NOT remove ashes
DO NOT allow children and animals to come near the pellet boiler
ADHERE TO REQUIREMENTS SET FORTH IN THIS DOCUMENT
For correct use of the boiler, also heed to the following instructions:
Use only and exclusively fuel recommended by boiler manufacturer;
Follow instructions for maintenance;
Clean the boiler firebox for each pellet container used (3-14 days, when the pellet boiler and
ashes in it are cool);
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
17
DO NOT use the pellet boiler in case of operation malfunction or other irregularities,
abnormal noises and/or suspicious faults and IMMEDIATELY contact authorized service
personnel;
DO NOT spill water on the boiler, as well as put out fire in the combustion chamber with
water;
DO NOT lean on the boiler, as it may be unstable and could tip over;
DO NOT use the pellet boiler as support or a fastening item. Do not leave the container cover
open;
DO NOT touch the painted surfaces of the boiler during operation;
DO NOT use wood or charcoal in the pellet boiler, use only pellets with the following
properties:
dimension: diameter 6 mm,
maximum length: 30 mm,
moisture content: up to 10 %,
combustion value: minimum 16,9 MJ/kg or 4,7 kWh/kg,
ash content: below 0,7 %
DO NOT use the boiler as an incinerator;
Always ensure maximum safety.
6. INSTRUCTIONS FOR SAFE IGNITION AND CLEANING OF
BOILER
NEVER use fuel oil, lamp oil or any other oil or any other flammable liquid to ignite the pellet boiler.
Store all such liquids far away from the pellet boiler during operation.
Ensure that the pellet boiler is positioned properly and that it does not move.
Ensure that you have closed the firebox properly, and that it is closed during operation of the pellet
boiler.
Vacuum ashes only when the pellet boiler is cool.
Do not use abrasive products to clean the pellet boiler.
6.1. REGULAR MAINTENANCE AND CLEANING OF BOILER
Use of vacuum cleaner with separator will make cleaning ashes from the boiler easier.
Before starting any kind of maintenance, also cleaning, heed to the following safety precautions:
Shut off the pellet boiler before performing any kind of work
Before performing any kind of work on the boiler, make sure that the ashes in the boiler are
cool
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
18
Vacuum ashes from the combustion at least once every ten days or at each used pellet container
(only when the boiler is cool) (figure 10).
Vacuum and carefully clean the combustion container at least once every ten days or at each used
pellet container (only when the boiler is cool) (figure 10).
Once a month, remove the front door at the bottom of the exchanger on the right side of the boiler
and vacuum the inside (figure 10).
Always make sure that the pellet boiler and ashes in it are
cool.
This is the combustion container for burning pellets
(figure 9). We recommend inspecting and cleaning ashes
from the bottom of combustion chamber upon each
cleaning. When you place the combustion container back
in its place, make sure that it is set correctly: it must be
pushed towards the back wall all the way. Only then you
can be sure that the boiler will function properly.
Figure 9
Figure 10
ATTENTION
Be careful that the sealant rope under the edge of combustion chamber is not damaged. If
the sealant rope is damaged, contact an authorized service centre.
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
19
If you require any explanation do not hesitate and contact your installer. Because the manufacturer
has no control of the installer's work, he cannot guarantee performance of his work and
maintenance.
The manufacturer shall in no way be held responsible for damages caused by third parties.
ATTENTION
Ensure that the pellet boiler and ashes in it are cool!
The combustion chamber must be cleaned after each used pellet container, vacuumed and/or
emptied of all impurities remaining after the pellets have burned.
Never put pellets which have not burned back in the pellet container or ash box.
6.2. CONTROL AND PARTS REQUIRING MAINTENANCE
CHECK THE FOLLOWING ITEM AND MAKE SURE THAT THE PELLET BOILER IS OPERATING PROPERLY.
THIS WILL INCREASE ITS EFFICIENCY AND THE EMITTED HEAT INTO THE SYSTEM WILL ALSO INCREASE:
Ensure that the pellet boiler and ashes in it are cool!
For perfect cleaning, vacuum ashes from beneath the combustion container and from
combustion chamber every week or at each 200 kg pellet container used (whichever comes
sooner). Use a broom or a brush to clean firebox walls.
Clean the fan for extraction of smoke gases by removing fan protection and cleaning fan
blades with a broom or a brush.
GENERAL BOILER CLEANING AFTER THE END OF SEASON OR BEFORE THE START OF SEASON:
Ensure that the pellet boiler and ashes in it are cool!
Disconnect power supply!
At the end of heating season, disconnect the boiler from electrical network. It is very
important to clean and inspect the boiler, as described in the instructions.
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
20
Door seal, fitted with high-temperature resistant fitting material, can detach after prolonged
use. To reattach it, apply high-temperature fitting material on the back of the seal. This
ensures hermetic sealing of firebox doors.
FLUE CONNECTION – CHIMNEY (must be cleaned at the end of each season):
Ensure that the pellet boiler and ashes in it are cool!
Flue duct, chimney and chimney cover must be inspected and cleaned every year. Contact
your chimney sweep for professional service.
6.3. ADDITIONAL MAINTENANCE
Your pellet boiler is a heat generator which uses pellets. Therefore, it requires a special type of
maintenance by authorized personnel of company Gorenje d.d. each year.
Regular annual maintenance keeps the combustion device in good condition, ensures greater
efficiency, retains warranty and extends life expectancy of the device.
Type of work, described in the previous chapter, is advisable to perform after the end of heating
season. Their purpose is to check and ensure flawless operation of all components.
7. IMPORTANT SAFETY INFORMATION
You have purchased a product of the highest quality.
The supplier is at your disposal in transferring required information. Correct installation of
combustion device in accordance with instructions is important to prevent any poor functioning,
hazard or risk of fire.
Pellet boiler operates on the basis of negative pressure in the combustion chamber. Therefore, always
ensure that the flue connection is thermally sealed.
ATTENTION
In the event of fire in the flue pipe, all persons and animals must leave the area, then
immediately disconnect power supply from the main switch or socket (if it is possible
without risk) and call the fire department.
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
21
ATTENTION
Do not use fine cut wood to ensure operation and safety of the boiler.
ATTENTION
Do not use the pellet boiler as an incinerator.
8. PELLET QUALITY IS VERY IMPORTANT
The pellet boiler is designed for use with pellets. Because the market offer many types and
dimensions of pellets, it is very important to obtain pellets free from impurities. Make sure that you
use only pellets that are compact and dust-free. Ask your supplier for suitable pellets with 5 mm
diameter 30 mm length. Proper operation of the pellet boiler depends on the type and quality of
pellets.
Pellets are filled in the pellet container from above through the opening in foldable cover of the
container (figure 11). Make sure that, during filling, no hard objects foil or other objects that could
interfere with the operation of dosing screw, do not enter the pellet container.
Figure 11
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
22
ATTENTION
Persons with back injuries and pregnant women should avoid lifting pellet bags.
ATTENTION
The manufacture shall in no way be held liable for damages arising from the use of poor
quality pellets, as well as for poor functioning of the boiler due to poor quality of used
pellets.
ATTENTION
Pellets should be in accordance with DIN 51731, DIN plus, Ö-Norm M-7135 or other
comparable European standards.
8.1. STORING PELLETS
Pellets must be stored in a dry and not too cold place.
Cold and damp pellets (temperature about 5 °C) reduce thermal power and require more frequent
boiler cleaning.
ATTENTION
PELLETS SHOULD NOT BE STORED NEAR THE PELLET BOILER. Keep them at least 1/2 metre
away.
When handling pellets, be careful not to scatter them.
If you fill the pellet container with sawdust, it can block the pellet dosing system.
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
23
9. DESCRIPTION AND OPERATION OF CONTROL DEVICE
DESCRIPTION OF KEYBOARD WITH DISPLAY (plastic keyboard)
DESCRIPTION OF KEYBOARD WUTH DISPLAY (aluminium keyboard)
Indicator of turned
on timer system
+ and – buttons for water temperature adjustment
ON/OFF button,
exit from set up
menu
Upper display
Indicator of
operating feeding
screw
UP and DOWN buttons,
For a quick set up of power of the boiler. When in MENU we use the buttons to move between selection
MENU button,
Quick set up enter and enter to the main menu
Lower display
Upper display
Lower display
+ and – buttons for water temperature adjustment
ON/OFF button,
exit from set up
menu
UP and DOWN buttons,
For a quick set up of power of the boiler. When in MENU we use the buttons to move between selection
MENU button,
Quick set up enter and enter to the main menu
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
24
Display Function
upper display shows boiler status, chosen menu and indicates dosing
operation and operation in time programme
lower display shows current time, value of settings and parameters
and warning names
spark plug operation indicator
pump operation indicator
dosing operation indicator
Display during boiler operation in burning phase
Upper display: upper display alternately shows:
BURN and then P5D5, where Px means actual current operation power
and DX set operation power
Lower display:
lower display alternately shows:
Temperature of smoke gases: 155
Temperature of water in the boiler: B72
Temperature of return water: r45
Display during boiler standstill:
Upper display: OFF
Lower display:
Time: 18:35
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
25
Button Function
ON/OFF button
Press and hold to turn the boiler on/off.
Short press to return to basic display.
Button UP
Press during operation to increase set power.
When pressing MENU button beforehand, this button increases desired water
temperature in the boiler. In menu mode, we select desired submenu by pressing.
Button DOWN
Press during operation to decrease set power.
When pressing MENU button beforehand, this button decreases desired water
temperature in the boiler. In menu mode, we select desired submenu by pressing.
MENU button
Short press in basic display shows set value of water temperature in the boiler,
which can then be modified with buttons + and -.
Press and hold for at least 2 seconds to activate menu mode.
Press and hold for at least 4 seconds to enter advanced menu settings. Subsequent
pressing of the button display menu choices.
Use buttons + and - to select parameters in submenus. Short press MENU button
and set value of parameter starts flashing, which can then be modified with buttons
+ and -.
Short press ON/OFF button and hold MENU button to scroll all menu choices and
return to basic display.
Button +
Press during operation to increase desired temperature water in the boiler for a
degree
T
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
26
Button –
Press during operation to
decrease desired water temperature in the boiler for a degree.
9.1. BOILER DURING OPERATION
The display shows current operation phase (e.g. TestFire, HeatUp etc.). Upper display shows set and
actual boiler power alternately every 5 seconds.
Press button + to increase set power value, and press button – to decrease it.
Press MENU button to display set water temperature in the boiler. You can modify it with buttons +
and -.
The boiler operates at set power, until water temperature in the boiler reaches modulation threshold
or until smoke gases reach limits. In first case, Regu H20 is displayed, and in second Regu Gas.
In case of power outage for less than 2 minutes, the boiler resumes normal operation when power
supply restores. If the outage lasts more than 2 minutes, the boiler automatically performs safety
shutdown and cooling and then restarts.
9.2. BOILER SHUTDOWN
When pressing and holding the ON/OFF button for more than half a second (during boiler operation),
the display shows ON, and the boiler starts shutdown sequence once the button is released. Dosing
screw turns off and the display indicates STOP FIRE. Fans operate at high speed to prevent excessive
increase of water temperature in the boiler. When the boiler cools down under set temperature, fans
switch to maximum speed and blow out the last parts from the firebox. Display indicates OFF.
9.3. BOILER ACTIVATION
When pressing and holding the ON/OFF button for more than half a second (boiler at standstill), the
display shows OFF, and the boiler begins activation sequence once the button is release. Display
indicates TESTFIRE. Fans operate at high speed to clean the firebox. Dosing screw is at standstill,
spark plug is heating.
If the firebox temperature is low, sequence HEAT UP begins, where pellets are dosed quickly and fans
stand still. Then sequences Fuel IGNI and TEST IGNI start, until the boiler reaches conditions for
transition to burning phase (BURN).
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
27
ATTENTION
By pressing and holding MENU button for 2 seconds (release the button when tH20 displays),
the display indicates current water temperature in the boiler. By pressing button UP or button
DOWN you select display of other temperatures and fan status .
9.4. TIME PROGRAMME SETTING
Press and hold (until TEN displays) MENU button to access time programme menu.
By setting ON or OFF, the time programme activates or deactivates.
Accurate time and current day of the week (1 is Monday etc.) must be set and then, 6 programme
periods and temperatures must be programmed.
Each of 6 time period is determined by start (P1a – programme 1 start time) and end time (P1d –
programme 1 end time). In this period, the boiler is active and operates by maintaining water
temperature in the boiler (P1t).
Then select up to 3 time periods for each day of the week.
Example (Tuesday): upper display shows DAY2, and lower P1, P3 and P6, which means that the boiler
will be active on Tuesday in periods, programmed with programmes P1, P3 and P6.
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
28
Figure 12: Diagram of timer settings
9.5. INDICATIONS AND MESSAGES ON DISPLAY
Indication on
display
Explanation of message and status of the boiler
OFF
1 2 :5 3
The boiler is at a standstill.
°OFF
1 2 :5 3
The boiler is at a standstill, but the time programme is active and will start
automatically, as set with time programme.
TEST
FIRE
The boiler checks if there is a flame in the firebox and for proper combustion this
sequence starts after power supply outage.
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
29
Hea t
UP
In ignition phase, when the dosing screw filled the firebox, spark plug heats
pellets to ignition.
Fuel
IGNI
After Heat up phase, the boiler ignites pellets. No dosing in this phase.
TST
IGNI
At the end of ignition phase, the boiler shuts off the spark plug and tests, if the
ignition was successful and if combustion is correct and temperatures rise
correctly.
BURN
1 2 3 °
Burning phase (normal work phase). Lower display shows temperature of smoke
gases at exit from the boiler.
BURN
B78°
Burning phase. Lower display shows water temperature in the boiler.
BURN
R48°
Burning phase. Lower display shows temperature of return water.
P5D5
R48°
Burning phase. Upper display shows current power of the boiler (Px) and set
power of the boiler (Dx).
CLN
FIRE
Cleaning phase. Fans blow out ash and other residues from the firebox. This
phase starts automatically from time to time during burning phase.
FIRE
STOP
The boiler is in stopping sequence and is cooling down.
COOL
FLUID
When water temperature in the boiler, even with minimum power, reaches set
temperature, the boiler enters phase COOL FLUID and cools down. The boiler
restarts automatically when the water in the boiler cools down under set value.
ALAR
PEL
Lack of pellets in burning phase.
ALAR
FIRE
Unsuccessful ignition. Check boiler status, clean firebox and try to reignite the
boiler.
ALAR
SEC
Thermal safety activated. Check boiler status and, if no anomalies are
determined, manually reactivate safety and restart the boiler, or contact the
service centre.
ALAR
PRES
Safety pressure control activated. Check boiler status and, if no anomalies are
determined, restart the boiler, or contact the service centre.
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
30
ALAR
TC1
No signal of smoke gases sensor. Contact the service centre.
ALAR
TCh
No signal of firebox temperature. Contact the service centre.
ALAR
AIr
No signal of flow sensor or the fans do not operate properly. Contact the service
centre.
ALAR
drtY
Clean the boiler and/or flue.
ALAR
NTC
No signal of water temperature. Contact the service centre.
ALAR
GASS
Temperature of smoke gases is too high.
10. MENU
When holding MENU button, menus scroll. To select a certain menu, release the button when it is displayed. Descriptions of individual menus are provided below:
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
31
Figure 13: Menu description
Menu selection View
1. Water temperature in boiler
2. Ambient temperature (if the option is activated)
3. temperature of re-
turn water
4. Temperature of smoke gases
5. Temperature of combustion chamber
6. Air flow in sensor units
7. Negative pressure in chamber
8. Smoke fan speed
9. Primary fan voltage
10. Flue fan voltage
11. Screw 1 dosing percentage
12. Screw 2 dosing percentage
13. STB status of safety thermostat. Yes means
OK, No mean that it has turned on
14. Status of safety pressure control. Yes means OK, No means
error
15. Status of digital input 1 (D1): OPN – deactivated CLSD – activated
16. Status of digital input 2 (D2): OPN – deactivated CLSD – activated
17. Status of digital input 3 (D3): OPN – deactivated CLSD – activated
18. Status of digital input of speed sensor (SP): OPN – deactivated CLSD – activated
19. Operation time since last maintenance in
weeks
20. Software version
21. Firmware type
22. Pellet level option.
Display in cm from container bottom.
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
32
11. ALARM STATUSES
unsuccessful ignition
NO
NO
NO
YES
YE
S
NO service person
Are there pellets in the container?
Is STB turned on (protection active)?
Fill the container with
pellets
Deactivate protection by pressing button
Is the gasket pot celan?
Clean the gasket pot
Does the plug work? 1. Replace plug 2. Check output on electronics (relay) with voltmeter 3. Check safety relay
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
33
NO
NO
NO
YE
S
YE
S
NO
YE
S
service person
out of fuel
Are there pellets in the container?
Fill the container with
pellets
Is STB turned on (protection active)?
Deactivate protection by pressing button
Does mechanic pressure control for negative control
in firebox operate?
1. Check pressure control with artificially created negative pressure 2. Check sealing of doors and hatches on the boiler 3. Check air intake in the boiler room 4. Check flue draught 5. Clogged or dirty firebox
Does the dosing reduction work?
1. Check option of block screw 2. Check STB 4. Check the feeding screw
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
34
NO
NO
YE
S
YE
S
YE
S
NO
YE
S
service person
air flow through burner
Clogged air intake?
1. Check air intake into space 2. Check entry point of air into boiler 3. Check dirtiness of burning container and space beneath it
Does fan FAN1 (overpressure fan) work?
1. Check voltage output from electronics 2. Check white round safety pressure control 3. Check STB 4. Check functioning of safety relay 5. Replace fan
Are the tubes between electronics and flow meter in
order?
1. If torn or damaged, replace 2. If clogged or squeezed, clean or reinstall correctly
Is there a failure in flow meter? Replace electronics
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
35
NO
NO
NO
NO
YE
S
YE
S
YE
S
NO service person
fault of safety pressure control
Clogged air intake?
1. Check air intake into space 2. Check entry point of air into boiler 3. Check dirtiness of burning container and space beneath it
Are the tubes between electronics and flow meter
in order?
1. If torn or damaged, replace 2. If clogged or squeezed, clean or reinstall correctly
Is there a failure in flow meter?
Replace electronics
Does fan FAN1 (overpressure fan) work?
1. Check voltage output from electronics 2. Check white round safety pressure control 3. Check STB 4. Check functioning of safety relay 5. Replace fan
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
36
YE
S
YE
S
NO
NO
NO
service person
safety thermostat is clogged
Is boiler temperature above 95 degrees?
1. Cool the boiler and press button STB again 2. If the error remains, check set boiler temperature 3. Check heat take-off from boiler
1. Replace STB 2. Check wiring between STB and electronics in accordance with scheme
excessive temperature of smoke gases (above
250 degrees)
Is the exchanger clogged? 1. Check and clean the exchanger 2. In case of automatic cleaning, check operation of cleaning mechanism
Are all turbulators in their places?
Install or replace turbulators
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
37
NO
NO
YE
S
YE
S
service person
service person
electronics does not detect smoke gases
sensor
Is the sensor connected?
Is the sensor connected?
Replace sensor
Replace sensor
Connect sensor to correct position of electronics
Connect sensor to correct position of electronics
electronics does not detect firebox
temperature sensor
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
38
NO
NO
YE
S
YE
S
service person
electronics does not detect boiler water
sensor
Is the sensor connected?
Is the sensor connected?
Replace sensor
Replace sensor
Connect sensor to correct position of electronics
Connect sensor to correct position of electronics
electronics does not detect return water
sensor
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
39
12. INFORMATION REGARDING DESTRUCTION AND DISPOSAL OF BOILER
Destruction and disposal of pellet boiler is sole responsibility of the owner, who must act in accordance with laws in force in his country regarding safety, respect and protection of environment. Destruction and disposal of pellet boiler can be entrusted to a third person with licence or authorization for disposal and destruction of aforementioned materials. INDICATION: in any case, you must adhere to and respect laws in force in the county in which the pellet boiler is installed.
ATTENTION
All disassembled parts must be properly disposed of:
remove all electrical parts;
disconnect the battery from control device;
dispose of the battery of control device in accordance with norms in appropriate containers;
dispose of the boiler core or sell it as scrap metal.
ATTENTION
Disposed pellet boiler in accessible areas can present a serious danger for people and animals. Owner of the boiler is always responsible for damage caused.
Once the boiler is destructed, CE mark, Instructions for use, maintenance and installation and other documents regarding the boiler must also be destroyed.
13. WARRANTY CONDITIONS
OVERVIEW:
For the warranty to be completely valid, as set forth in Directive EEC 1999/44/E (42/2002), the user must carefully heed to instructions in this document, namely:
Use the pellet boiler in its limits, in accordance with the conditions set forth in the instructions for use;
Maintain the pellet boiler in a diligent and constant manner;
Regard all safety precautions in accordance with laws in force;
Avoid any unprofessional tampering with the boiler;
Use only original spare parts.
WARRANTY TIME CONDITIONS: Warranty for all Gorenje products is valid for 24 months from the date of first start-up, given that a regular maintenance inspection is performed no later than 24 months from the date of start-up.
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
40
GENERAL WARRANTY CONDITIONS: 1. We declare:
that the product will function flawlessly in the warranty period, if used in accordance with the purpose of use, and if enclosed Instructions for use and maintenance will be adhered to;
that, in the warranty period, company Gorenje will, through authorized service companies, resolve all faults/defects, due to which the device is not working in accordance with purpose, no later than 45 days from written report of fault or defect;
that a product, not repaired in the aforementioned deadline, will be, at the request of warranty holder, replaced with a new one, and the warranty period will extend for the time of the repair;
that authorized service company guarantees warranty conditions with signature and stamp on published warranty.
2. Calling on the warranty: Warranty is valid under the condition that:
The customer possesses a valid document (receipt), issued by salesman.
The combustion device was installed by a qualified and/or trained person, who determines if the device meets all technical characteristics of the system where the device will be installed to, and must be necessarily in accordance with requirements set forth in the instructions.
The pellet boiler is used in accordance with the instructions for use. Warranty is called on at the salesman, where you have purchased the device. Upon claiming fault, provide an accurate description of fault – defect. 3. Period of guaranteeing service and spare parts:
warranty period, in which we guarantee service and spare parts for undisturbed use of the product, is 7 years from the day of first start-up;
in case of replacing production models ECOLOGIC 30, we guarantee spare parts for your product for 3 years;
after 7 years, spare parts will be available, but they may be available in different colour than your product.
4. Warranty is void or does not cover damages, caused by:
Weather, chemical or electrochemical influences, lightning strikes, elementary accidents and/or natural disasters, incorrect use of the product, insufficient maintenance, modifications to the product or tampering with the product, unsuitable or inefficient flue and other reasons not connected to the product, such as incorrect or unsuitable installation;
Burning of materials, which do not correspond with the type of material given in these instructions;
Any kind of damage caused by/during transport. Therefore, carefully inspect delivered goods upon reception. If it is damaged, immediately inform the salesman, and record the damage on admission document or supply order;
If the start-up was performed by a company without appropriate authorization for Gorenje products;
If the product has been tampered with or repaired by an unauthorized person;
If the user does not comply with the instructions for use and maintenance;
If defects or faults arise on the heating device ECOLOGIC 30 due to defects on equipment of other manufacturers.
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
41
Liability of company Gorenje d.d. is limited to unit supply. Unit must be installed properly in accordance with manufacturer instructions, as well as with laws in force. Installation must be performed by qualified personnel, defined by the manufacturer or representative/salesman1 (and/or under his supervision and liability), who assumes full responsibility for final installation and subsequent correct operation of installed product. In case of non-fulfilment of conditions, company Gorenje d.d. is not liable in any case. 1 As representative/salesman is considered any natural person or legal entity authorized for sales of products to end users of this warranty. NOTE: Gorenje d.d. shall not be held liable for any damage and consequences, even if these are a consequence of replacement of malfunctioning part of the boiler. Gorenje d.d. guarantees that all of its products are made of materials of highest quality and with manufacturing processes, which ensure perfect efficiency. If during normal use, there should be any defective or malfunctioning parts, they must be replaced.
PARTS, SUBJECT TO NORMAL WEAR, NOT COVERED BY WARRANTY :
Seals and cast iron parts, which do not show any signs of faults, which could be attributed to manufacturing error;
Changes in colour, cracks and small dimensional modifications are not substantiated and do not present grounds for rejection, as they are a consequence of natural characteristics of materials.
LIABILITY: Gorenje d.d. shall not recognize any compensation for direct or indirect damage caused by or related to the product.
SERVICE DURING WARRANTY PERIOD: Gorenje d.d. handles problems regarding warranty only through its authorized persons.
COMPETENT COURT: The Court of Koper shall have jurisdiction for settling disputes. In the event of replacement of parts, the warranty is not extended. No reimbursement is acknowledged for the period of time, during which the product could not be used. Gorenje d.d. is not liable for any mistakes in the instructions. We reserve the right to changes without any prior notice.
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
42
14. TECHNICAL CHARACTERISTICS OF MODEL ECOLOGIC 30
Minimal Nominal
Thermal power 8,65 kW 30,80 kW
Efficiency 91,92 % 91,94 %
Pellet consumption per hour 1,92 kg/h 6,82 kg/h
Burning time with 1 filling of container
(approx.) 93,8 h 26,4 h
CO emissions (at 13 % O2) 155 mg/m³ 10 mg/m³
Average temperature of smoke gases 56,8 °C 114,9 °C
Mass flow of smoke gases 0,0071 0,0152
Fuel Pellets C1
Boiler class (fuel) C1
boiler class according to EN 303-5:2012 5
Flue connection Ø80 mm
Water volume in boiler 74 l
Boiler water temperature 65 °C – 80 °C
Highest boiler water temperature 90 °C
Minimum return water temperature 50 °C
Maximum permitted work pressure 2 bar
Boiler resistance ΔT = 20 °C 38 mbar
Firebox volume 60,44 l
Weight 240 kg
Fuel Pellets – C1
Pellet container ~ 200 kg
Flue draught 0,11 (± 0,02) mbar
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
43
Voltage 220 V
Current at maximum electrical consumption during boiler operation 1,80 A
frequency 50 Hz
Maximum consumption of power during boiler operation 78,5 W
Minimum consumption of power during boiler operation
Maximum consumption of power during boiler ignition 328,5 W
Safety level IP20
Boiler operates with two fans
Boiler operates only in manner of negative pressure combustion
Boiler operates without condensation conditions
Noise does not exceed 70 dB
15. DIMENSIONS OF BOILER ECOLOGIC 30
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
44
__________
Instructions for installers
__________
This part of the instructions is intended solely for installer and contains all key information for
installation and connection of combustion device ECOLOGIC 30.
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
45
1. Boiler room
Figure 14: Boiler room example
installation
flue
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
46
2. Boiler parts
Remove the back coating to access components at the back of the boiler (figure 16).
Figure 15: Important boiler parts
Ho
lder
fo
r
sup
ply
cab
les
Gea
rbo
x Si
lico
n t
ub
es
Flu
e ga
s ve
nti
lato
r
Def
lect
or
pla
te
Elec
tro
nic
s
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
47
Figure 16: Removing back cover (net)
Remove the back coating (net), which covers all the elements of the boiler, by unscrewing all the
bolts. Access to boiler parts from the back is now possible.
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
48
3. Boiler connection instructions
To connect boiler ECOLOGIC 30 to central heating system you must check:
It is necessary to take into account the installations of non-return valve spring (or other
locking elements) which automatically prevent uncontrolled circulation of the heating
medium through the boiler by natural gravitational path.
Correct installation of pipelines of central heating (pipeline dimensions, air extraction, pipe
system functionality, adequacy of heating system according to boiler power).
Distribution units (pump functionality, closing valves functionality, electrical zone valves func-
tionality, mixed valves functionality…).
Ensured inlet of air into the space where ECOLOGIC 30 combustion device is installed. Inlet
must be executed in a manner, so that it cannot be closed and must, at any moment, enable
supply of fresh air – oxygen for burning into space. Unsuitable solutions are slightly opened
windows or open doors, supply of air through a duct along the flue from the roof is also un-
suitable.
Voltage of electrical connection for combustion device ECOLOGIC 30 must be 230 V / 50 Hz
(given in technical data for boiler ECOLOGIC 30).
Inspection of outlet of smoke gases – flue. Condition for connection is consent from chimney
sweep, with which a chimney sweep ensure suitability of the flue for combustion device ECO-
LOGIC 30.
In placing and connecting the combustion device to central heating system, the installer must adhere
to the following:
Boiler ECOLOGIC 30 must be positioned horizontally, in length and depth.
Distances, according to the enclosed drawing, must be regarded (see figure 1, page 7).
In cases of older installation on return line to combustion device ECOLOGIC 30, a cleaning ele-
ment with closing valves is installed.
Boiler ECOLOGIC 30 is fitted with safety valve of 2.5 bar on return line. Installer must ensure
proper size of expansion container for volume of heating water in the system (size of expan-
sion container must be dimensioned minimum of 10 % of water volume in system "150 litres
of heating water in the system, minimum volume of expansion container must be 15 l". ex-
pansion container must be installed on combustion device ECOLOGIC 30 without closing ele-
ments.
A filling release tap must be installed on the right side of the boiler, on connection DN20 (see
figure 17, page 49).
Minimal pressure of heating water in boiler of 0.7 bar is ensured.
In case where there are many heating loops (two direct loops or mix loops for radiator heat-
ing, boiler heating, convector heating), connection scheme nr. 3 (page 54) is always used,
where it is necessary to use a hydraulic switch and pump on boiler loop, which is electrically
connected to cable "pump" from the boiler (see figure 8, page 13).
Boiler must be fitted with pressure gauge for pressure of heating water in the boiler, i.e. on
pipeline before each closing valve (enable that the pressure gauge indicates pressure in the
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
49
boiler and system; in the time of filling "there cannot be a closing element, which could pre-
vent indication of pressure in the boiler in the time of filling"). On the right side of ECOLOGIC
30 (see figure 17, page 49) is a provided DN20 connection for filling release tap. Filling re-
lease tap is intended for filling or emptying the heating system and boiler.
When connecting the boiler ECOLOGIC 30 to central heating system you must use mechanical
elements, which prevent uncontrolled circulation of hot heating water through the boiler
(gravity block, spring non-return valve, solenoid zone valve, electromotor zone valve...). goal
of protection is to ensure amount of heating water flow through the boiler (minimal flow
through the boiler must be over 300 l/h).
When distribution of heating water is regulated by three-way mix valve (floor heating,
weather controlled regulation, where water flow on boiler heating loop is reduced), the sys-
tem is executed with fitted hydraulic switch and pump on primary-boiler heating loop, pump
on boiler heating loop must be controlled by boiler regulation, which already has a factory
produced electrical connection for pump.
When a three-way mix valve is used (for floor or radiator heating, only in case of only one
mixing heating loop), connection of boiler ECOLOGIC 30 is always executed according to
scheme nr. 3 (page 54), where a hydraulic switch and a pump are built into the installation on
heating cycle with non-return valve (pump is connected to black cable from combustion de-
vice).
Flue connection must executed in accordance with instruction limiting maximum length of
connection pipe Ø 80 (5 m) and that 90-degree joints are considered as resistance on connec-
tion, which reduces length of connection pipe for 1 m (example: if there are 2 joints on flue
connection, the connection cannot exceed length of 3 m). Flue connection must be fitted
with joints with inspections holes for cleaning (see figure 3, page 10). Joints must be out of at
least 3 segments (joints with three or more segments enable smooth flow of smoke gases
through joint), it is prohibited to use joints with two segments (joints with two segments cre-
ates resistance in flow of smoke gases) (see figure 6, page 11).
If the flue connection is longer as set forth in the instructions, the installer must use a reduc-
ing element (from Ø 80 female connection to Ø 130 female connection) immediately behind
the fan, and the connection must be made with a pipe Ø 130 (see figure 18, page 49)
Electrical connection of boiler must be performed with a cable (see figure 8, page 13) in ac-
cordance with instructions. The boiler must not be connected to power supply with a plug –
it must be connected directly to network by a toggle switch, breaking live and neutral wire
(see figure 19, page 49).
Electrical connection of distribution elements (pumps, solenoid valves, electromotor valves...)
must be executed in accordance with the scheme in the instructions, i.e. supply for distribu-
tion elements must be executed from connection cable on the boiler (cable "pump") (see fig-
ure 8, page 13).
Combustion device ECOLOGIC 30, pipes of central heating and flue connection must be
earthed in accordance with professional regulations (earthing conductor with minimum
cross-section 4mm2) (see figure 20, page 49).
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
50
Figure 17 Figure 18 Figure 19 Figure 20
Figure 21: Activating thermal safety
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
51
4. CONNECTION SCHEMES
4.1. SCHEME NR.1: HEATING ONLY
Connection scheme 1
clea
nin
g el
emen
t
exp
ansi
on
co
nta
iner
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
52
Electrical scheme 1
BO
ILER
EA
RTH
ING
MA
ND
ATO
RY
ECO
LOG
IC 3
0 S
UP
PLY
rad
iato
r p
um
p
PU
MP
SU
PP
LY
S.T.
– r
oo
m t
her
mo
stat
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
53
4.2. SCHEME NR.2: HEATING HOUSE + HOUSEHOLD HOT WATER
Connection scheme 2
exp
ansi
on
co
nta
iner
clea
nin
g el
emen
t
rad
iato
rs
el. z
on
e va
lve
bo
iler
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
54
Electrical scheme 2
BO
ILER
EA
RTH
ING
MA
ND
ATO
RY
ECO
LOG
IC 3
0 S
UP
PLY
P
UM
P S
UP
PLY
S.T.
– r
oo
m t
her
mo
stat
byp
ass
pu
mp
– s
wit
ch
tem
p. b
oile
r
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
55
4.3. SCHEME NR.3: HEATING WITH MULTIPLE SYSTEMS
This type of connection always requires a hydraulic switch.
Connection scheme 3
exp
ansi
on
co
nta
iner
clea
nin
g el
emen
t
flo
or
hea
tin
g b
oile
r ra
dia
tors
auto
mat
ics
hyd
rau
lic s
wit
ch
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
56
Electrical scheme 3
BO
ILER
EA
RTH
ING
MA
ND
ATO
RY
ECO
LOG
IC 3
0 S
UP
PLY
P
UM
P S
UP
PLY
byp
ass
pu
mp
– s
wit
ch
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
57
__________
Instructions for first start-up
__________
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
58
ECOLOGIC 30 is a combustion device for heating with pellets. Benefits of combustion device
ECOLOGIC 30 lie in advanced technology that enables automatic identification of oxygen contents in
air, automatic identification of flue draught and automatic identification of pellet quality. When one
of the former factors is unsuitable, combustion device ECOLOGIC 30 indicates an alarm on the display
on unsuitability or fault for lacking (example: if the flue is clogged or does not provide extraction of
smoke gases, ECOLOGIC 30 displays "ALARM PRESS").
Overview of alarms is on page 31.
Figure 22a: Overview of keyboard buttons (plastic keyboard):
Figure 22b: Overview of keyboard buttons (aluminium keyboard):
+ and – buttons
for water
temperature
adjustment
ON /OFF button,
exit from set up
menu
UP and DOWN buttons,
for a quick set up of
power of the boiler. In
MENU use this buttons to
move between selections
MENU button, quick set
up enter and enter to
the main menu
+ and – buttons for
water temperature
adjustment
UP and DOWN buttons,
for a quick set up of power
of the boiler. In MENU use
this buttons to move
between selection
ON /OFF button,
exit from set up
menu
MENU button, quick set
up enter and enter to the
main menu
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
59
When the installer makes the connection to central heating system, to chimney with flue connection
and to electrical network in accordance with instructions for installers, the boiler is ready for start-up.
After checking details from instructions for installers, combustion device ECOLOGIC 30 can be
commissioned with ON/OFF button (see figure 22) by the installer, who installed the device.
Upon first start-up, the installer must be careful of correct order of events (displays):
Press and hold ON/OFF button for 3 seconds. Display indicates ON, and immediately after
"Test fire" – lasts 10 seconds, then goes to:
"Heat up" – quick filling of combustion container with pellets, alternately displaying P0 d5 (in
upper display) and changing temperatures; b – temperature of heating water in the boiler, only
number – temperature of smoke gases and r – temperature of return line (in lower display),
then goes to:
"Fuel igni" – ignition of combustion device ECOLOGIC 30 (upon first ignition, ignition phase can
last longer, even up to 10 minutes) lasting approximately 5 minutes, alternately displaying P0
d5 in upper display and temperature in lower display, then goes to:
"Igni test" – checking ignition, display also changes between igni test and P0 d5, and tempera-
tures in the lower display. When checking is done, it goes to:
"Burn" – boiler operation, upper display indicates Burn, lower display indicates changing b-
temperature of heating water in the boiler, smoke gases and r-temperature of water in the
boiler:
LED in upper display above right signals operation of reducer for dosing pellets (when the LED
is turned on, the reducer is dosing pellets into the burner and vice versa: if the light is turned
off, the reducer is not operating).
LED in the lower display below right signals when the boiler is supplying pump with voltage –
when the pump is operating (when the light is turned on, the pump is supplied with power,
which means that the pump is operating and vice versa: if the LED is turned off, the pump is
not operating),
When the temperature of heating water begins to gets closer to set temperature, combustion
device ECOLOGIC 30 starts modulation or regulation/reduction of power. In this state, display
indicates "regu H2O", and upper display alternately shows power (P is the level of boiler opera-
tion, d is the level of boiler setting), and lower display shows temperatures.
"Cool flui" – state of shutting down, indicated on the display when combustion device ECO-
LOGIC 30 reaches set temperature of heating water in the boiler with addition for regulation (if
the temperature of heating water is set to 70 °C, the boiler enter "cool flui" state at 75 °C).
When the boiler finishes "Cool flui" state, it means that the heating water in the boiler cooled
down. It goes to:
"Test fire" – and the ignition procedure is repeated.
Control of information on operation of combustion device ECOLOGIC 30 requires menu access into
programme of information (shown data is only illustrative). Enter the menu with long press on MENU
button (see figure 22, page 58), when the display shows "tH2O", release the button. Use + and -
buttons to select desired information.
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015
60
Displayed information is:
tH2O temperature of heating water in the boiler
rH2O temperature of heating water on return
tFLU temperature of smoke gases ((H2O )+30-90°C),
tChb temperature of fire in combustion chamber (615°C+-40°C)
floU inlet of air-oxygen into combustion device (480°C +- 40°C)
FanI voltage on fan 1 (130V +- 15V)
FedI percentage of pellet dosing into the burner (70% +- 20%)
Once you have completed viewing information, use + and - buttons to find information "tH2O". When
finding it, short press ON/OFF button to return to previous state.
If the display indicates "alarm", cause of the alarm must be determined with alarm list (see page 31).