29
KINGSEAM SERIES ROOF PANEL DATE: 2019 SHEET INDEX DETAIL #: CI-DS-01-KINGSEAM C & I DISCLAIMER CI-PP-01-KINGSEAM PANEL PROFILE CI-PJ-01-KINGSEAM PANEL JOINT CI-PJ-02-KINGSEAM PANEL JOINT SEQUENCE CI-PJ-03-KINGSEAM PANEL JOINT AT INTERMEDIATE SUPPORT CI-PJ-04-KINGSEAM PANEL JOINT LAYOUT CI-EL-01-KINGSEAM ENDLAP CI-EL-02-KINGSEAM STAGGERED ENDLAP ASSEMBLY CI-EL-03-KINGSEAM MALE LEG ENDLAP CI-EL-04-KINGSEAM CONTINUOUS MALE LEG AT STAGGERED ENDLAP CI-EL-05-KINGSEAM FEMALE LEG ENDLAP CI-EL-06-KINGSEAM ENDLAP CONDITIONS CI-RD-01-KINGSEAM RIDGE CI-RD-02-KINGSEAM RIDGE ASSEMBLY CI-RD-03-KINGSEAM RIDGE CLOSURE ASSEMBLY CI-RD-04-KINGSEAM RIDGE TRIM LAP CI-EV-01-KINGSEAM LOW EAVE W/O GUTTER CI-EV-02A-KINGSEAM LOW EAVE W/ GUTTER CI-EV-02B-KINGSEAM GUTTER HANGER CI-EV-02C-KINGSEAM LOW EAVE SEALANT AT STANDING RIB CI-EV-03-KINGSEAM HIGH EAVE CI-RK-01-KINGSEAM RAKE CI-VL-01-KINGSEAM VALLEY CONDITION CI-VL-02-KINGSEAM VALLEY ASSEMBLY CI-WR-01-KINGSEAM WALL TO ROOF HIGH EAVE CI-WR-02-KINGSEAM MASONRY WALL TO HIGH EAVE CI-WR-03-KINGSEAM WALL TO RAKE CI-WR-04-KINGSEAM MASONRY WALL TO ROOF CI-##-##-KINGSEAM www.kingspanpanels.us www.kingspanpanels.ca

KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

  • Upload
    others

  • View
    17

  • Download
    0

Embed Size (px)

Citation preview

Page 1: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

KINGSEAM SERIES ROOF PANEL

DATE: 2019

SHEET INDEX

DETAIL #:

CI-DS-01-KINGSEAM C & I DISCLAIMER

CI-PP-01-KINGSEAM PANEL PROFILE

CI-PJ-01-KINGSEAM PANEL JOINT

CI-PJ-02-KINGSEAM PANEL JOINT SEQUENCE

CI-PJ-03-KINGSEAM PANEL JOINT AT INTERMEDIATE SUPPORT

CI-PJ-04-KINGSEAM PANEL JOINT LAYOUT

CI-EL-01-KINGSEAM ENDLAP

CI-EL-02-KINGSEAM STAGGERED ENDLAP ASSEMBLY

CI-EL-03-KINGSEAM MALE LEG ENDLAP

CI-EL-04-KINGSEAM CONTINUOUS MALE LEG AT STAGGERED

ENDLAP

CI-EL-05-KINGSEAM FEMALE LEG ENDLAP

CI-EL-06-KINGSEAM ENDLAP CONDITIONS

CI-RD-01-KINGSEAM RIDGE

CI-RD-02-KINGSEAM RIDGE ASSEMBLY

CI-RD-03-KINGSEAM RIDGE CLOSURE ASSEMBLY

CI-RD-04-KINGSEAM RIDGE TRIM LAP

CI-EV-01-KINGSEAM LOW EAVE W/O GUTTER

CI-EV-02A-KINGSEAM LOW EAVE W/ GUTTER

CI-EV-02B-KINGSEAM GUTTER HANGER

CI-EV-02C-KINGSEAM LOW EAVE SEALANT AT STANDING RIB

CI-EV-03-KINGSEAM HIGH EAVE

CI-RK-01-KINGSEAM RAKE

CI-VL-01-KINGSEAM VALLEY CONDITION

CI-VL-02-KINGSEAM VALLEY ASSEMBLY

CI-WR-01-KINGSEAM WALL TO ROOF HIGH EAVE

CI-WR-02-KINGSEAM MASONRY WALL TO HIGH EAVE

CI-WR-03-KINGSEAM WALL TO RAKE

CI-WR-04-KINGSEAM MASONRY WALL TO ROOF

CI-##-##-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

Page 2: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

KINGSEAM SERIES ROOF PANEL

DATE:

COMMERCIAL/INDUSTRIAL

DISCLAIMER

DETAIL #:

DISCLAIMER:

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED

COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

LOCATION OF VAPOR BARRIERS AND ASSOCIATED SEALANTS IN THESE DETAILS ARE BASED

ON TYPICAL DESIGN PRACTICES FOR MOST U.S. CLIMACTIC ZONES. (THE PRIMARY VAPOR

BARRIER IS PLACED ON THE "WARM" SIDE IN WINTER).

PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY

REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES

FOR SPECIFIC PROJECT RECOMMENDATIONS.

CI-DS-01-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2018 REV2

Page 3: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

CORE DEPTHS:

3.25", 4", 5", 6"

STEEL GAUGES:

EXTERIOR: 26ga STANDARD

(22ga, 24ga OPTIONAL )

INTERIOR: 26ga STANDARD

(22ga, 24ga OPTIONAL )

MODULE WIDTH:

40"

PANEL ORIENTATION:

ROOF ONLY

EMBOSSING:

EXTERIOR: SMOOTH

INTERIOR: SMOOTH

LENGTHS:

MINIMUM: 8'-0"

MAXIMUM: 50'-0"

STANDING SEAM

MINIMUM SLOPE:

1

2

" : 12" (2° SLOPE)

40" (1016MM)

2"

1"

3.25", 4", 5", 6"

MESSA

EXTERIOR

INTERIOR

PANEL PROFILE

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-PP-01-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 4: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

FACTORY-APPLIED

FOAM GASKET

AT UNDERSIDE

OF ROOF CLIP

KINGSEAM ROOF PANEL

(SR) CLIP W/

1

4

" Ø TEK

FASTENERS W/O WASHER

PER PANEL AT EACH

SECONDARY SUPPORT

NOTE: DO NOT OVER-DRIVE FASTENERS. IF THE

METAL AT THE EDGE OF THE PANEL IS

DEFORMED OUT OF PLANE, THE ADJACENT

PANEL WILL BE DIFFICULT TO ENGAGE AND WILL

NOT SEAM. AFTER SR CLIP HAS BEEN INSTALLED

IN PLACE OVER MALE LEG OF STANDING SEAM

PANEL, PRE-CRIMP USING

1

2

" HAND CRIMPING

TOOL.

ROOF INSTALLATION DIRECTION

CONTINUOUS

BUTYL SEALANT

IN FEMALE JOINT

FIELD-APPLIED

1

8

" BEAD

OF BUTYL SEALANT ON

UNDERSIDE OF PANEL

CLIP

FIELD-APPLIED

1

4

" BEAD

OF NON-SKINNING BUTYL

SEALANT

(_)

1

4

" x 2" TEK _ FASTENERS

W/O WASHER PER CLIP

(CONTACT KINGSPAN TECHNICAL SERVICES FOR

PROJECT SPECIFIC FASTENING REQUIREMENTS)

PANEL JOINT

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-PJ-01-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 5: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

1 SET PANEL IN PLACE, WITH CONTINUOUS

BUTYL SEALANT ALONG STANDING RIB

2 INSTALL KINGSEAM (SR) CLIP, AND

HEX HEAD FASTENERS

3 HAND "CRIMP" THE (SR) CLIP AT EACH

CLIP LOCATION

4 INSTALL CONTINUOUS BUTYL SEALANT

AT FEMALE JOINT OF NEXT PANEL

5 ENGAGE PANEL JOINTS

6 USE CLAMPS TO SECURE STANDING

SEAM ASSEMBLY

7 HAND CRIMP STANDING SEAM ASSEMBLY

AT CLIP LOCATIONS

NOTE: DO NOT OVER DRIVE FASTENERS. IF METAL

AT THE EDGE OF PANEL IS DEFORMED OUT OF

PLANE, THE ADJACENT COURSE OF PANELS WILL BE

DIFFICULT TO ENGAGE AND WILL NOT SEAM.

FIELD OR FACTORY

APPLIED

1

4

" BEAD OF

NON-SKINNING BUTYL

SEALANT

CONTACT KINGSPAN TECHNICAL SERVICES FOR

PROJECT SPECIFIC FASTENING REQUIREMENTS

PANEL JOINT

SEQUENCE

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-PJ-02-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 6: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

NOTE: DO NOT OVER-DRIVE FASTENERS. IF THE METAL AT THE EDGE OF THE

PANEL IS DEFORMED OUT OF PLANE, THE ADJACENT PANEL WILL BE

DIFFICULT TO ENGAGE AND WILL NOT SEAM. AFTER SR CLIP HAS BEEN

INSTALLED OVER MALE LEG OF STANDING SEAM PANEL, PRE-CRIMP, USING

1

2

" HAND CRIMPING TOOL.

ROOF PANEL CLIP W/

(_)

1

4

- 14 x 2" TEK 3 W/O

WASHER AT EACH

SECONDARY SUPPORT

FIELD-APPLIED BUTYL

SEALANT AT UNDERSIDE

OF CLIP

FIELD-APPLIED BUTYL

SEALANT AT CLIP

OVERLAP

SECONDARY FRAMING

(NOT BY IMP SUPPLIER)

FACTORY-APPLIED FOAM

GASKET AT UNDERSIDE

OF SR ROOF CLIP

CONTINUOUS BUTYL

SEALANT IN FEMALE

JOINT

NOTE: FASTENING

SCHEDULE MAY VARY

DEPENDING ON SPECIFIC

APPLICATION.

(_)

1

4

" x 2" TEK _ FASTENERS

W/O WASHER PER CLIP

(CONTACT KINGSPAN TECHNICAL

SERVICES FOR PROJECT SPECIFIC

FASTENING REQUIREMENTS)

PANEL JOINT AT

INTERMEDIATE

SUPPORT

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-PJ-03-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 7: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

FIE

LD

C

UT

T

HE

F

EM

AL

E L

EG

O

F T

HE

S

TA

RT

ER

P

AN

EL

A

S N

EC

ES

SA

RY

S

O T

HA

T

BO

TH

P

AN

EL

S L

OC

AT

ED

A

T T

HE

R

AK

E C

ON

DIT

IO

NS

A

RE

O

F E

QU

AL

W

ID

TH

40

" (F

UL

L M

OD

UL

E)

R

A

K

E

EQ

UA

LE

QU

AL

40

" (F

UL

L M

OD

UL

E)

RID

GE

DIR

EC

TIO

N O

F IN

ST

AL

LA

TIO

N

EA

VE

R

A

K

E

PANEL JOINT LAYOUT

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-PJ-04-1000

www.kingspanpanels.us

www.kingspanpanels.ca

2018 REV2

Page 8: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

ROOF PANEL CLIP W/

(_)

1

4

- 14 x 2" TEK _

FASTENERS W/O

WASHER PER CLIP, PER

PANEL AT EACH LAP

SECONDARY SUPPORT

CONTINUOUS

1

2

" Ø BEADS

OF GUN-GRADE

NON-SKINNING BUTYL

SEALANT ACROSS PANEL

AT END-LAP

NOTE: DO NOT OVER-DRIVE FASTENERS. IF

THE METAL AT THE EDGE OF THE PANEL IS

DEFORMED OUT OF PLANE, THE ADJACENT

PANEL WILL BE DIFFICULT TO ENGAGE AND

WILL NOT SEAM. AFTER SR CLIP HAS BEEN

INSTALLED OVER MALE LEG OF STANDING

SEAM PANEL, PRE-CRIMP, USING

1

2

" HAND

CRIMPING TOOL.

1" x

3

16

" BUTYL

TAPE SEALANT

SUPPORT ANGLE AND

FASTENERS BY OTHERS

(NOT BY IMP SUPPLIER)

1

4

- 14 x

7

8

" STITCH

TEKS 2

1

2

" O/C AT LAP

SECONDARY FRAMING

(NOT BY IMP SUPPLIER)

FACTORY-APPLIED FOAM

GASKET AT UNDERSIDE

OF SR ROOF CLIP

FIELD-APPLIED BUTYL

SEALANT ON UNDERSIDE

OF SR CLIP

NOTE: BUTYL SEALANT AND BUTYL

TAPE TO RUN ACROSS FULL WIDTH

OF PANELS; NOT SHOWN AT HIGH

RIBS FOR CLARITY.

FIELD-APPLIED BUTYL

SEALANT AT PANEL

OVERLAP

CONTINUOUS BUTYL

SEALANT IN FEMALE

JOINT (TYP)

CONTINUOUS BUTYL SEALANT W/

MARRIAGE BEAD TO FEMALE JOINT

BUTYL SEALANT END

DAM AT ALL ENDLAP

JOINTS

CONTACT KINGSPAN TECHNICAL SERVICES FOR

PROJECT SPECIFIC FASTENING REQUIREMENTS

ENDLAP

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-EL-01-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 9: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

1F

AS

TE

NE

RS

A

T E

VE

RY

2

1

2

" O

.C

. A

T LA

P

2E

ND

LA

PS

M

US

T B

E S

TA

GG

ER

ED

3S

EE

M

ALE

LE

G E

ND

LA

P D

ET

AIL

4S

EE

C

ON

TIN

UO

US

M

ALE

LE

G D

ET

AIL

5S

EE

F

EM

ALE

LE

G E

ND

LA

P D

ET

AIL

15

43

ST

AG

GE

RE

D E

ND

LA

P A

SS

EM

BLY

(IS

OM

ET

RIC

V

IE

W - T

YP

IC

AL)

STAGGERED ENDLAP

ASSEMBLY

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-EL-02-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 10: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

6" E

ND

LA

P C

UT

BA

CK

(S

EE

N

OT

E)

EA

VE

P

RE

PA

RA

TIO

N

(IS

OM

ET

ER

IC

V

IE

W)

US

E M

ET

AL S

NIP

S T

O C

UT

O

FF

T

HE

EX

PO

SE

D M

ET

AL E

DG

E A

T T

HE

SID

E JO

IN

T F

AC

E A

T E

AC

H S

ID

E O

F

RO

OF

P

AN

EL F

OR

P

RO

PE

R

NE

ST

IN

G O

F U

PP

ER

C

OU

RS

E O

F

OV

ER

LA

PP

IN

G K

IN

GS

EA

M R

OO

F

PA

NE

L

LO

WE

R C

OU

RS

E

KIN

GS

EA

M S

TA

ND

IN

G

SE

AM

P

AN

ELS

3" E

AV

E C

UT

BA

CK

(S

EE

N

OT

E)

EN

DLA

P P

RE

PA

RA

TIO

N

(IS

OM

ET

RIC

V

IE

W)

UP

PE

R C

OU

RS

E

KIN

GS

EA

M S

TA

ND

IN

G

SE

AM

P

AN

ELS

5

3

4

"

6

"

NO

TE

: C

ON

TR

AC

TO

R S

HA

LL R

EM

OV

E

FO

AM

F

RO

M 3" C

UT

BA

CK

B

EN

EA

TH

EX

TE

RIO

R F

AC

ER

. E

XT

RA

C

AR

E

SH

OU

LD

B

E T

AK

EN

T

O R

EM

OV

E F

OA

M

CLE

AN

LY

F

RO

M M

ET

AL T

HA

T W

ILL B

E

DIR

EC

TLY

O

VE

R B

UT

YL T

AP

E O

R

SE

ALA

NT

.

NO

TE

: C

ON

TR

AC

TO

R S

HA

LL R

EM

OV

E F

OA

M

FR

OM

E

ND

LA

P C

UT

BA

CK

IN

T

HE

F

IE

LD

.

EX

TR

A C

AR

E S

HO

ULD

B

E T

AK

EN

T

O R

EM

OV

E

FO

AM

C

LE

AN

LY

F

RO

M M

ET

AL T

HA

T W

ILL B

E

DIR

EC

TLY

O

VE

R B

UT

YL T

AP

E S

EA

LA

NT

.

FIE

LD

-A

PP

LIE

D

1

4

"

BE

AD

O

F

NO

N-S

KIN

NIN

G B

UT

YL

SE

ALA

NT

BU

TY

L S

EA

LA

NT

EN

D D

AM

A

T A

LL

EN

DLA

P JO

IN

TS

BU

TY

L S

EA

LA

NT

EN

D D

AM

A

T A

LL

EN

DLA

P JO

IN

TS

(A

LT

ER

NA

TE

IS

OM

ET

RIC

V

IE

W)

(A

LT

ER

NA

TE

S

EC

TIO

N V

IE

W)

MALE LEG

ENDLAP

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-EL-03-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 11: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

EN

DLA

P P

RE

PA

RA

TIO

N (C

ON

T.)

(IS

OM

ET

ER

IC

V

IE

W)

(1) R

OW

O

F B

UT

YL T

AP

E

SE

ALA

NT

(2) R

OW

S O

F

1

2

" Ø

B

EA

D

NO

N-S

KIN

NIN

G B

UT

YL

SE

ALA

NT

UP

PE

R K

IN

GS

EA

M

PA

NE

LS

PLA

CE

B

UT

YL S

EA

LA

NT

DIR

EC

TLY

B

EN

EA

TH

S

R

CLIP

B

EF

OR

E A

TT

AC

HIN

G

WIT

H F

AS

TE

NE

RS

, T

YP

.

AT

A

LL LO

CA

TIO

NS

.

LO

WE

R K

IN

GS

EA

M

PA

NE

LS

CO

NT

IN

UO

US

B

UT

YL T

AP

E O

R

SE

ALA

NT

@

LO

W E

AV

E S

TR

UT

CO

NT

IN

UE

R

OW

S O

F

BU

TY

L S

EA

LA

NT

&

B

UT

YL

TA

PE

U

P &

O

VE

R T

HE

T

OP

OF

T

HE

V

ER

TIC

AL LE

G

BU

TY

L S

EA

LA

NT

E

ND

D

AM

AT

A

LL E

ND

LA

P JO

IN

TS

CONTINUOUS MALE

LEG AT STAGGERED

ENDLAP

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-EL-04-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 12: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

AF

TE

R P

AN

EL C

LIP

H

AS

B

EE

N

PLA

CE

D O

VE

R M

ALE

LE

G O

F

ST

AN

DIN

G S

EA

M P

AN

EL,

PR

E-C

RIM

P U

SIN

G (S

UP

PLIE

D)

1

2

" H

AN

D C

RIM

PIN

G T

OO

L A

T

EV

ER

Y C

LIP

P

RIO

R T

O

EN

GA

GIN

G T

HE

N

EX

T P

AN

EL

CO

UR

SE

.

FA

ST

EN

D

OW

N P

AN

EL C

LIP

W

IT

H

1

4

- 14 x 2" T

EK

FA

ST

EN

ER

S (S

UP

PLIE

D). D

O N

OT

O

VE

R D

RIV

E

FA

ST

EN

ER

S. IF

M

ET

AL A

T T

HE

E

DG

E O

F P

AN

EL IS

DE

FO

RM

ED

O

UT

O

F P

LA

NE

, T

HE

A

DJA

CE

NT

C

OU

RS

E O

F

PA

NE

LS

W

ILL B

E D

IF

FIC

ULT

T

O E

NG

AG

E A

ND

W

ILL N

OT

SE

AM

.

UP

PE

R K

IN

GS

EA

M

PA

NE

LS

LO

WE

R K

IN

GS

EA

M

PA

NE

LS

SR

P

AN

EL C

LIP

P

RE

PA

RA

TIO

N

(IS

OM

ET

ER

IC

V

IE

W)

BU

TY

L T

AP

E O

R S

EA

LA

NT

@

LO

W E

AV

E

ST

RU

T

BU

TY

L S

EA

LA

NT

E

ND

D

AM

AT

A

LL E

ND

LA

P JO

IN

TS

FEMALE LEG

ENDLAP

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-EL-05-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 13: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

BU

TY

L T

AP

E O

R S

EA

LA

NT

P

LA

CE

ME

NT

(IS

OM

ET

ER

IC

V

IE

W)

UP

PE

R K

IN

GS

EA

M

PA

NE

LS

LO

WE

R K

IN

GS

EA

M

PA

NE

LS

ON

CE

U

PP

ER

P

AN

EL IS

IN

PLA

CE

A

ND

F

AS

TE

NE

D,

FA

ST

EN

D

OW

N T

HE

EN

DLA

P U

SIN

G

1

4

- 14 x

7

8

"

ST

IT

CH

T

EK

S 2

1

2

" O

/C

BU

TY

L T

AP

E O

R S

EA

LA

NT

@

LO

W E

AV

E

ST

RU

T

BU

TY

L S

EA

LA

NT

E

ND

D

AM

AT

A

LL E

ND

LA

P JO

IN

TS

ENDLAP CONDITIONS

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-EL-06-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 14: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

RO

OF

P

AN

EL C

LIP

W

/

(_)

1

4

- 14 x 2" T

EK

W

/O

WA

SH

ER

, P

ER

C

LIP

, P

ER

PA

NE

L A

T R

ID

GE

SE

CO

ND

AR

Y S

UP

PO

RT

NO

TE

: D

O N

OT

O

VE

R-D

RIV

E

FA

ST

EN

ER

S. IF

T

HE

M

ET

AL A

T T

HE

ED

GE

O

F T

HE

P

AN

EL IS

D

EF

OR

ME

D

OU

T O

F P

LA

NE

, T

HE

A

DJA

CE

NT

P

AN

EL

WILL B

E D

IF

FIC

ULT

T

O E

NG

AG

E A

ND

WILL N

OT

S

EA

M. A

FT

ER

S

R C

LIP

H

AS

BE

EN

IN

ST

ALLE

D O

VE

R M

ALE

LE

G O

F

ST

AN

DIN

G S

EA

M P

AN

EL, P

RE

-C

RIM

P,

US

IN

G

1

2

" H

AN

D C

RIM

PIN

G T

OO

L.

"IR

-01" IN

SID

E R

ID

GE

W

/

#10 x

3

4

" P

PH

12" O

/C

SR

2 O

UT

SID

E C

LO

SU

RE

ST

RIP

S

ET

IN

1" x

3

16

"

BU

TY

L T

AP

E S

EA

LA

NT

A

T

TO

P A

ND

B

OT

TO

M

"S

RC

-02" M

ET

AL

CLO

SU

RE

W

/

1

4

- 14 x

7

8

" S

TIT

CH

T

EK

6" O

/C

SE

T IN

1" x

3

16

" B

UT

YL

TA

PE

S

EA

LA

NT

A

T

TO

P A

ND

B

OT

TO

M

"O

R-01" O

UT

SID

E R

ID

GE

1

4

- 14 x

7

8

" S

TIT

CH

TE

K 6" O

/C

FILL G

AP

C

ON

TIN

UO

US

LY

W

IT

H

TW

O-P

AR

T F

OA

ME

D-IN

-P

LA

CE

UR

ET

HA

NE

; F

OR

D

RY

, M

ILD

CLIM

AT

ES

C

OM

PR

ES

SIB

LE

IN

SU

LA

TIO

N M

AY

B

E U

SE

D

(N

OT

B

Y IM

P S

UP

PLIE

R)

SE

CO

ND

AR

Y F

RA

MIN

G

BY

O

TH

ER

S

(N

OT

B

Y IM

P S

UP

PLIE

R)

1

2

"

BU

TY

L S

EA

LA

NT

E

ND

DA

M (T

YP

. B

OT

H S

ID

ES

)

CO

NT

IN

UO

US

B

UT

YL

SE

ALA

NT

W

/ M

AR

RIA

GE

BE

AD

T

O F

EM

ALE

JO

IN

T

( T

YP

)

RIDGE

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-RD-01-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 15: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

1

4

" - 14 X

7

8

" STITCH TEK 6" O.C.

OUTSIDE RIDGE TRIM

5

5

BUTYL TAPE

SRC-02 METAL CLOSURE

SR2 OUTSIDE CLOSURE

5

4

3

3

3

2

2

2

1

FIELD FILL WITH COMPRESSIBLE

INSULATION OR FIELD FOAM WITH

2-PART URETHANE (NOT BY KINGSPAN)

SET IN BUTYL TAPE

TOP AND BOTTOM

1

4

" - 14 HEX HEAD FASTENERS

(AS REQUIRED FOR WIND LOAD)

SET PANELS AND CLIPS

SET IN CONTINUOUS BUTYL SEALANT

W/ MARRIAGE BEADS TO PANEL JOINT

INSIDE RIDGE TRIM

NOTE: # 'S REFER TO SEQUENCE OF INSTALLATION

1

1

2

"

ROOF

PANEL CLIP

RIDGE ASSEMBLY

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-RD-02-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

REVIEW RIDGE AND CONFIRM

Page 16: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

FIE

LD

N

OT

CH

S

RC

-0

2 M

ET

AL

C

LO

SU

RE

TO

F

IT

S

EA

M

FO

AM

N

OT

CH

F

IT

S IN

TO

S

EA

M

NO

TE

S:

1. P

AN

EL

S N

EE

D T

O B

E C

OM

PL

ET

EL

Y IN

ST

AL

LE

D A

ND

F

UL

LY

S

EA

ME

D B

EF

OR

E B

EG

IN

NIN

G R

ID

GE

IN

ST

AL

LA

TIO

N

2. P

AN

EL

G

UID

E L

IN

E M

AR

KS

S

HO

UL

D B

E U

SE

D T

O P

OS

IT

IO

N C

OM

PO

NE

NT

S C

OR

RE

CT

LY

3. A

PP

LY

C

ON

TIN

UO

US

B

UT

YL

T

AP

E A

CR

OS

S E

NT

IR

E P

AN

EL

IN

CL

UD

IN

G V

ER

TIC

AL

L

EG

S. S

ET

S

R2

F

OA

M C

LO

SU

RE

IN

TO

PL

AC

E, T

HE

N A

PP

LY

C

ON

TIN

UO

US

B

UT

YL

T

AP

E O

VE

R T

OP

O

F F

OA

M C

LO

SU

RE

4. F

AS

TE

N S

RC

-0

2 M

ET

AL

R

ID

GE

C

LO

SU

RE

T

RIM

A

T 6

" O

.C

. (F

AS

TE

NE

R S

PA

CIN

G M

AY

V

AR

Y W

IT

H W

IN

D L

OA

D)

5. A

T T

HE

R

AK

ES

, F

IE

LD

C

UT

T

HE

E

ND

O

F T

HE

F

OA

M C

LO

SU

RE

A

ND

R

ID

GE

C

LO

SU

RE

T

RIM

T

O F

IT

W

IT

H T

HE

R

AK

E F

AS

CIA

6. S

EE

R

ID

GE

D

ET

AIL

S C

I-R

D-0

1-K

IN

GS

EA

M &

C

I-R

D-0

2-K

IN

GS

EA

M F

OR

A

DD

IT

IO

NA

L IN

FO

RM

AT

IO

N

NO

TE

: S

R2

F

OA

M C

LO

SU

RE

D

OE

S N

OT

RE

QU

IR

E S

RC

-0

2 R

ID

GE

C

LO

SU

RE

T

RIM

.

BU

TY

L T

AP

E T

OP

A

ND

BO

TT

OM

O

F C

LO

SU

RE

RIDGE CLOSURE

ASSEMBLY

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-RD-03-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

RE

VIE

W R

ID

GE

A

ND

C

ON

FIR

M

NE

ED

S N

EW

P

RO

FILE

S

Page 17: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

3

"

L

A

P

2" BUTYL TAPE or

MIN. 2 BEADS OF

BUTYL SEALANT

INSTALLED OUTSIDE

RIDGE TRIM

OUTSIDE RIDGE TRIM

TO LAP INSTALLED TRIM

L

A

P

3

"

L

A

P

3

"

2

"

B

U

T

Y

L

T

A

P

E

o

r

2

B

E

A

D

S

O

F

B

U

T

Y

L

S

E

A

L

A

N

T

OUTSIDE RIDGE TRIM

REMOVE 3" OF HEM

ON LAPPING TRIM

FASTEN 1" FROM SEAM

1

"

1

4

" - 14 X

7

8

" LOW

PROFILE TEK

SCREWS

@ 3" SPACING / 1"

FROM SEAM

RIDGE TRIM LAP

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-RD-04-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 18: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

INSIDE CLOSURE

STRIP W/ 1" x

3

16

"

BUTYL TAPE SEALANT

AT TOP & BOTTOM

1

4

- 14 x

7

8

" STITCH

TEKS 6" O/C

"LE-__" LOW

EAVE TRIM

CONTINUOUS BUTYL

SEALANT IN FEMALE

JOINT

EAVE STRUT

(NOT BY IMP SUPPLIER)

ROOF PANEL CLIP W/

(_)

1

4

- 14 x 2" TEK _

FASTENERS W/O

WASHER PER CLIP,

PER PANEL AT EAVE

STRUT

NOTE: FIELD REMOVE FOAM

AND LINER AT CUTBACK.

NOTE: DO NOT OVER-DRIVE FASTENERS. IF THE METAL AT THE EDGE OF THE

PANEL IS DEFORMED OUT OF PLANE, THE ADJACENT PANEL WILL BE

DIFFICULT TO ENGAGE AND WILL NOT SEAM. AFTER SR CLIP HAS BEEN

INSTALLED OVER MALE LEG OF STANDING SEAM PANEL, PRE-CRIMP, USING

1

2

"

HAND CRIMPING TOOL.

CONTINUOUS BUTYL

SEALANT AT VERTICAL

JOINT

BUTYL SEALANT END

DAM; FILL INTERIOR

JOINT CAVITY

POP RIVETS @

8" O.C.

EXPANDABLE INSULATION

(NOT BY KINGSPAN)

14 GA. HIDDEN

FASTENER CLIP (1 PER

PANEL, PER GIRT)

CONTINUOUS BUTYL

SEALANT W/ MARRIAGE

BEAD TO PANEL JOINT

(2)

1

4

" - 14 HEX HEAD

FASTENERS PER CLIP

CT-__ CAP TRIM

3"

CU

TB

AC

K

LOW EAVE W/O

GUTTER

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-EV-01-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 19: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

"BB-01" BIRD BLOCK W/

1

4

- 14 x

7

8

" STITCH TEK

12" O/C

ROOF PANEL CLIP W/ (_)

1

4

-

14 x 2" TEK 3 W/O WASHER

PER CLIP, PER PANEL AT

EAVE STRUT

NOTE: FIELD REMOVE FOAM AND LINER AT CUTBACK.

"GS-02S" GUTTER

HANGER 20" O/C W/

(5)

1

4

- 14 x

7

8

" STITCH

TEKS

1

4

- 14

7

8

"

STITCH TEKS

6" O/C

"GT-__S" GUTTER TRIM

BUTYL TAPE SEALANT STRIP

UNDER GUTTER STRAP

EAVE STRUT

(NOT BY IMP SUPPLIER)

NOTE: DO NOT OVER-DRIVE FASTENERS. IF THE METAL AT THE EDGE OF THE

PANEL IS DEFORMED OUT OF PLANE, THE ADJACENT PANEL WILL BE

DIFFICULT TO ENGAGE AND WILL NOT SEAM. AFTER SR CLIP HAS BEEN

INSTALLED OVER MALE LEG OF STANDING SEAM PANEL, PRE-CRIMP, USING

1

2

"

HAND CRIMPING TOOL.

CONTINUOUS BUTYL

SEALANT AT VERTICAL

JOINT

INSIDE CLOSURE STRIP

W/ 1" x

3

16

" BUTYL TAPE

SEALANT AT TOP &

BOTTOM

FIELD-FILL W/

COMPRESSIBLE

INSULATION

(NOT BY IMP SUPPLIER)

1

1

8

"

3"

CU

TB

AC

K

14 GA. HIDDEN

FASTENER CLIP (1 PER

PANEL, PER GIRT)

CONTINUOUS BUTYL

SEALANT W/ MARRIAGE

BEAD TO PANEL JOINT

1

4

" - 14 HEX HEAD

FASTENERS

BUTYL SEALANT END

DAM; FILL INTERIOR

JOINT CAVITY

CONTINUOUS BUTYL

SEALANT IN FEMALE JOINT

CT-__ CAP TRIM

LOW EAVE W/ GUTTER

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-EV-02A-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 20: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

GUTTER HANGER

1

'

-

6

3

8

"

1

4

" - 14 X

7

8

" LOW

PROFILE TEK SCREWS

(DO NOT LOCATE AT

FASTENER AT CLIP

LOCATION)

20" O.C. 20" O.C.

BUTYL TAPE

GUTTER HANGER

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-EV-02B-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 21: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

CONTINUOUS

BUTYL TAPE

LOW EAVE TRIM

CONTINUOUS

BUTYL SEALANT

BUTYL SEALANT

MARRIAGE BEAD

AT STANDING RIB

KINGSEAM STANDING

RIB AT PANEL JOINT

EXTERIOR PANEL

FACE AT CUTBACK

INSIDE

CLOSURE STRIP

LOW EAVE SEALANT

AT STANDING RIB

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-EV-02C-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 22: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

SR-_ ROOF PANEL CLIP W/ (_)

1

4

- 14

x 2" TEK FASTENERS W/O WASHER,

PER CLIP, PER PANEL AT HIGH

EAVE STRUT

"HE-01S" HIGH

EAVE TRIM

POP RIVETS

@ 8" O.C.

HIGH EAVE STRUT

(NOT BY IMP SUPPLIER)

NOTE: DO NOT OVER-DRIVE FASTENERS. IF THE METAL AT THE EDGE OF THE

PANEL IS DEFORMED OUT OF PLANE, THE ADJACENT PANEL WILL BE

DIFFICULT TO ENGAGE AND WILL NOT SEAM. AFTER SR CLIP HAS BEEN

INSTALLED OVER MALE LEG OF STANDING SEAM PANEL, PRE-CRIMP, USING

1

2

"

HAND CRIMPING TOOL.

CONTINUOUS BUTYL

SEALANT AT

VERTICAL JOINT

OUTSIDE CLOSURE STRIP

SET IN 1" x

3

16

" BUTYL TAPE

AT TOP AND BOTTOM

"SRC-02" METAL

CLOSURE W/

1

4

- 14 x

7

8

"

STITCH TEK 6" O/C

1

4

- 14 x

7

8

" STITCH

TEK 12" O/C

1" x

3

16

" BUTYL TAPE

SEALANT AT TOP AND

BOTTOM

1

2

"

CONTINUOUS BUTYL

SEALANT W/ MARRIAGE

BEAD TO PANEL JOINT

(2)

1

4

" - 14 HEX HEAD

FASTENERS PER CLIP

14 GA. HIDDEN

FASTENER CLIP (1 PER

PANEL, PER GIRT)

EXPANDABLE

INSULATION

(NOT BY KINGSPAN)

BUTYL SEALANT

END DAM; FILL

INTERIOR JOINT

CAVITY

CT-__ CAP TRIM

CONTINUOUS BUTYL

SEALANT IN FEMALE

JOINT

HIGH EAVE

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-EV-03-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 23: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

"RF-01S" RAKE FASCIA

FIELD CUT PANEL AS

NEEDED FOR PROPER

LAYOUT REQUIREMENTS

"ST-01" STANDING

SEAM TRIM SUPPORT

1

4

- 14 x

7

8

" STITCH TEK 12" O/C

1" x

3

16

" BUTYL TAPE SEALANT

1

4

- 14 x _" TEK FASTENER W/

WASHER AT EACH PURLIN

SECONDARY FRAMING &

RAKE ANGLE

(NOT BY IMP SUPPLIER)

CONTINUOUS BUTYL

SEALANT W/ MARRIAGE

BEAD TO PANEL JOINT

CONTINUOUS BUTYL

SEALANT AT VERTICAL

JOINT

POP RIVETS @

8" O.C.

14 GA. HIDDEN

FASTENER CLIP (1 PER

PANEL, PER GIRT)

1

4

" - 14 HEX HEAD

FASTENERS

CONTINUOUS BUTYL

SEALANT

CT-__ CAP TRIM

RAKE

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-RK-01-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 24: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

FIE

LD

CU

T

BA

CK

*

UPPER VALLEY FLASHING

(FIELD BREAK FROM FLATSTOCK)

1

4

" - 14 X

7

8

" LOW

PROFILE TEK SCREWS

W/O WSHR 18" O.C

COMPLETELY FILL

VOID W/ COMPRESSIBLE

INSULATION (NOT BY

KINGSPAN)

7

5

4

1

4

" - 14 X

7

8

" TEK SCREWS

4" O.C. (IN LOWS)

1

4

" - 14 X

7

8

" LOW PROFILE

TEK SCREWS W/O WSHR

SEE BELOW FOR

ADDITIONAL INFO.

LOWER VALLEY

FLASHING (NOT BY

KINGSPAN). GAUGE TO

MATCH PURLIN

1

4

" - 14 HEX HEAD

FASTENERS

VALLEY SUPPORT ("Z"

SHAPE) SET IN

BUTYL SEALANT

3

1

2

SEQUENCE OF INSTALLATION:

1 LOWER VALLEY PAN

2 "Z" SHAPED VALLEY SUPPORT

3 FILL VOID W/ INSULATION

4 INSTALL SECONDARY & UPPER VALLEY PAN

5 APPLY TAPE MASTIC TO TOP OF UPPER VALLEY PAN

6 CUT ROOF PANELS. REMOVE CUT BACK

7 FASTEN ASSEMBLY

* FIELD CUT ROOF PANELS FOR 4

1

4

" OR 3" CUTBACK. CUTBACK SIZE

TO MACH THE EAVE CONDITION

FIE

LD

CU

T

BA

CK

FIELD NOTCH STANDING

SEAM AS NECESSARY

FIELD FOLD EXTERIOR SKIN

TO MATCH UPPER VALLEY

FLASHING

SR-_ ROOF PANEL CLIP W/

(_)

1

4

- 14 x 2" TEK 3 W/O

WASHER, PER CLIP, PER

PANEL AT SECONDARY

SUPPORT

CONTINUOUS BUTYL

SEALANT IN FEMALE

JOINT (TYP)

BUTYL SEALANT END

DAM; FILL INTERIOR

JOINT CAVITY

CONTINUOUS BUTYL

SEALANT BOTH SIDES OF

"Z" W/ MARRIAGE BEAD

TO PANEL JOINT

2

VALLEY ASSEMBLY

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-VL-02-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 25: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

PURLIN

AND FLASHINGS

VALLEY SUPPORT STEEL

GUTTERS

AT VALLEY CONDITION

FIELD CUTBACK

PANEL HIGH

RIB 42" O/C

ROOF VALLEY PLAN

TO MATCH FACTORY

CUTBACK AT EAVE

CONDITION

3" CUTBACK

VALLEY ASSEMBLY

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-VL-02-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 26: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

"TF-02" TRANSITION

FLASHING

SECONDARY FRAMING

(NOT BY IMP SUPPLIER)

ROOF PANEL CLIP W/ (_)

1

4

- 14 x 2" TEK _ FASTENERS

W/O WASHER, PER CLIP,

PER PANEL AT

SECONDARY SUPPORT

"TF-01" TRANSITION FLASHING

W/

1

4

- 14 x

7

8

" STITCH TEKS 12"

O/C

CONTINUOUS

BUTYL SEALANT W/

MARRIAGE BEAD

TO VERTICAL

JOINT

SECONDARY

FRAMING

(NOT BY IMP

SUPPLIER)

BUTYL SEALANT

AT VERTICAL

JOINT

"SRC-02" METAL CLOSURE

W/ STITCH TEK 6" O/C AND 1" X

3

16

" BUTYL TAPE SEALANT AT

TOP AND BOTTOM

SR2 OUTSIDE CLOSURE STRIP

SET IN 1" x

3

16

" BUTYL TAPE

SEALANT AT TOP AND BOTTOM

1

2

"

COVER TRIM W/

POP RIVETS @

8" O.C.

14 GA. HIDDEN

FASTENER CLIP (1 PER

PANEL, PER GIRT)

1

4

" - 14 HEX HEAD

FASTENERS

FIELD FILL WITH

EXPANDABLE

INSULATION

(NOT BY KINGSPAN)

CONTINUOUS BUTYL

SEALANT IN FEMALE

JOINT (TYP)

CONTINUOUS BUTYL

SEALANT W/ MARRIAGE

BEAD TO PANEL JOINT

BUTYL SEALANT END

DAM; FILL INTERIOR

JOINT CAVITY

WALL TO ROOF

HIGH EAVE

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-WR-01-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 27: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

"TF-02" TRANSITION

FLASHING

FIELD FILL WITH

EXPANDABLE

INSULATION

(NOT BY KINGSPAN)

FASTENERS TO MASONRY

(NOT BY KINGSPAN)

POURABLE SEALANT

(NOT BY KINGSPAN)

FIELD CUT MASONRY FOR INSTALLATION OF FLASHING,

FILL VOID WITH SEALANT (NOT BY KINGSPAN)

COUNTER

FLASHING

CONTINUOUS BUTYL

SEALANT AT JOINT

LOCATIONS

FRAMING

(NOT BY KINGSPAN)

SR-_ ROOF PANEL CLIP W/ (_)

1

4

- 14 x 2" TEK 3 W/O

WASHER, PER CLIP, PER PANEL AT SECONDARY

SUPPORT

"TF" TRANSITION FLASHING W/

1

4

- 14 x

7

8

" STITCH TEKS 12"

O/C

"SRC-02" METAL CLOSURE

W/ STITCH TEK 6" O/C AND 1" X

3

16

" BUTYL TAPE SEALANT AT

TOP AND BOTTOM

SR2 OUTSIDE CLOSURE STRIP

SET IN 1" x

3

16

" BUTYL TAPE

SEALANT AT TOP AND BOTTOM

1

2

"

CONTINUOUS BUTYL

SEALANT IN FEMALE

JOINT (TYP)

CONTINUOUS BUTYL

SEALANT W/ MARRIAGE

BEAD TO PANEL JOINT

MASONRY WALL

TO HIGH EAVE

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-WR-02-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 28: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

FIELD-CUT STANDING

SEAM AS REQUIRED

SECONDARY FRAMING &

SUPPORT ANGLE

(NOT BY IMP SUPPLIER)

"RT-01S" ROOF TO

WALL TRIM

1

4

- 14 x

7

8

" STITCH TEK

24" O/C

1" x

3

16

" BUTYL TAPE

SEALANT

(_)

1

4

- 14 x _ TEK

FASTENER W/ WASHER

AT EACH PURLIN

FIELD-FILL WITH

COMPRESSIBLE

INSULATION (NOT BY

IMP SUPPLIER)

CONTINUOUS BUTYL

SEALANT AT VERTICAL

JOINT

COVER TRIM W/

POP RIVETS @

8" O.C.

14 GA. HIDDEN

FASTENER CLIP (1 PER

PANEL, PER GIRT)

CONTINUOUS

BUTYL SEALANT W/

MARRIAGE BEAD

TO VERTICAL

JOINT

1

4

" - 14 HEX HEAD

FASTENERS

"TF-02" TRANSITION

FLASHING

CONTACT KINGSPAN TECHNICAL SERVICES FOR

PROJECT SPECIFIC FASTENING REQUIREMENTS

WALL TO RAKE

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-WR-03-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019

Page 29: KINGSEAM SERIES ROOF PANEL - az750602.vo.msecnd.net · kingseam series roof panel date:2019 sheet index detail #: ci-ds-01-kingseam c & i disclaimer ci-pp-01-kingseam panel profile

FASTENERS TO MASONRY

(NOT BY KINGSPAN)

POURABLE SEALANT

(NOT BY KINGSPAN)

FIELD CUT MASONRY FOR INSTALLATION OF FLASHING,

FILL VOID WITH SEALANT (NOT BY KINGSPAN)

COUNTER FLASHING

TRANSITION FLASHING

1

4

" - 14 X

7

8

" STITCH

TEK SCREWS @ 8" O.C.

BUTYL TAPE

CONTINUOUS BUTYL SEALANT

RAKE ANGLE FOR PANEL ATTACHMENT

(NOT BY KINGSPAN)

FILL WITH EXPANDABLE INSULATION

(NOT BY KINGSPAN)

CONTINUOUS BUTYL SEALANT AT

RAKE ANGLE TO MASONRY

1

4

" - 14 THROUGH FASTENER

WITH 1

1

8

" BONDED WASHER

(AS REQUIRED FOR WIND LOAD)

MASONRY WALL TO

RAKE TRANSITION

KINGSEAM SERIES ROOF PANEL

DETAIL #:

DATE:

CI-WR-04-KINGSEAM

www.kingspanpanels.us

www.kingspanpanels.ca

2019