Keysight N5990A Type-C Extension

Page 2: Keysight N5990A Type-C Extension

Notices© Keysight Technologies 2017

No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or transla-tion into a foreign language) without prior agreement and written consent from Keysight Technologies as governed by United States and international copyright laws.

Manual Part Number

N5990-91210

Manual Edition

December, 2017

Keysight Technologies Deutschland GmbHHerrenberger Strasse 130,71034 Böblingen, Germany

Technology LicensesThe hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license.

U.S. Government Rights

The Software is “commercial computer software,” as defined by Federal Acquisition Regulation (“FAR”) 2.101. Pursuant to FAR 12.212 and 27.405-3 and Department of Defense FAR Supplement

(“DFARS”) 227.7202, the U.S. government acquires commercial computer software under the same terms by which the soft-ware is customarily provided to the public. Accordingly, Keysight provides the Soft-ware to U.S. government customers under its standard commercial license, which is embodied in its End User License Agree-ment (EULA), a copy of which can be found at http://www.keysight.com/find/sweula. The license set forth in the EULA represents the exclusive authority by which the U.S. government may use, modify, distribute, or

disclose the Software. The EULA and the license set forth therein, does not require or permit, among other things, that Key-sight: (1) Furnish technical information related to commercial computer software or commercial computer software docu-mentation that is not customarily provided to the public; or (2) Relinquish to, or other-wise provide, the government rights in excess of these rights customarily provided to the public to use, modify, reproduce, release, perform, display, or disclose com-mercial computer software or commercial computer software documentation. No additional government requirements beyond those set forth in the EULA shall apply, except to the extent that those terms, rights, or licenses are explicitly required from all providers of commercial computer software pursuant to the FAR and the DFARS and are set forth specifically in writing elsewhere in the EULA. Keysight shall be under no obligation to update, revise or otherwise modify the Software. With respect to any technical data as defined by FAR 2.101, pursuant to FAR 12.211 and 27.404.2 and DFARS 227.7102, the U.S. government acquires no greater than Limited Rights as defined in FAR 27.401 or DFAR 227.7103-5 (c), as appli-cable in any technical data.

Warranty

THE MATERIAL CONTAINED IN THIS DOCU-MENT IS PROVIDED "AS IS," AND IS SUB-JECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDITIONS. FURTHER, TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, KEYSIGHT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MER-CHANTABILITY AND FITNESS FOR A PAR-TICULAR PURPOSE. KEYSIGHT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDEN-

TAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS DOCU-MENT OR ANY INFORMATION CONTAINED HEREIN. SHOULD KEYSIGHT AND THE USER HAVE A SEPARATE WRITTEN AGREE-MENT WITH WARRANTY TERMS COVER-ING THE MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT WILL CONTROL.

Safety Notices

CAUTIONA CAUTION notice denotes a hazard. It calls attention to an operating pro-cedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met.

WARNINGA WARNING notice denotes a hazard. It calls attention to an operating pro-cedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.

2 Keysight N5990A Type-C Extension User Guide

Page 3: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide 3

Contents

1 Introduction

Overview 6

2 ValiFrame Station Configuration

2

USB 8

DisplayPort 9

Thunderbol t 10Remote Instruments Server 10Instrument Configuration 11

3 ValiFrame DUT Configuration

USB 14

DisplayPort 18

Thunderbol t 20

PDO Configuration 21

Page 4: Keysight N5990A Type-C Extension

4 Keysight N5990A Type-C Extension User Guide

Contents

4 Connection Diagrams

4

4

USB 26Rx Tests with M8020A 26LFPS Rx Tests with M8020A 28Rx Tests with N4903B 29

DisplayPort 31Rx Tests with M8020A 31Rx Tests with N4903B 33Rx Tests with ParBERT 7G 34Rx Tests for DP 2+2 mode 35

Thunderbol t 37Rx TP2 Tests with M8020A 37Rx TPEQ Tests with M8020A 39

5 Calibration Procedures

References 42

6 Rx Test Procedures

PDO Iterations Node 44

7 Contact Information

Page 5: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide

1 Introduction

Overview / 6

Page 6: Keysight N5990A Type-C Extension

6 Keysight N5990A Type-C Extension User Guide

1 Introduction

Overview

The Keysight Technologies N5990A Test Automation Software Platform “ValiFrame” is an open and flexible framework for automating tests of the latest digital bus standards.

This QuickStart guide describes how to configure the Type-C PDO test options in the ValiFrame Rx tests for USB3.1, DisplayPort and Thunderbolt.

The use of the PDOs (Power Data Object) allows the inclusion of different power contracts in the test plan.

The PDO test extension requires the option - 006 “Type-C enabling”. It is a supplement to the standard ValiFrame-USB, ValiFrame-Thunderbolt or ValiFrame-DisplayPort-Module. It only works in conjunction with a basic license for these standards.

NOTEThis document is just a short overview over the PDO test extension.It is not a complete manual for using those applications. For each particular standard, please refer to the following documents:

Keysight N5990A Test Automation Software Platform for USB

Keysight N5990A-155 Test Automation Software Platform for Display Port

Keysight N5990A-104 Test Automation Software Platform for Thunderbolt

Page 7: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide

2 ValiFrame Station Configuration

USB / 8DisplayPort / 9Thunderbolt / 10

Start the Station Configuration of the particular ValiFrame application to choose and connect to the relevant instrument setup.

In the Station Configuration window select the following options for Type-C PDO test support (Refer to Figure 1):

1 Check the option Test Type-C PDOs.

2 Choose a power supply. The main options are:

• N6786A: The N6786A is suitable for testing sink and source up to 20V.

• 5V Power Supply: The simple 5V power supply is just to bring a DUT to work, but not to test any PDOs. It maybe any fixed 5V supply with current capability sufficient for the DUT. The recommended minimum is 500mA.

Page 8: Keysight N5990A Type-C Extension

8 Keysight N5990A Type-C Extension User Guide

2 ValiFrame Station Configuration

USB

Figure 1 ValiFrame Station Configuration wizard

To choose the 5V power supply, select None as power supply. In this case, ValiFrame will not try to configure the power supply during the tests (for example, for link training or loop back purposes).

The other options are: E3631A, E363xA, E364xA and N67xx.

For a full featured PDO test of USB Type-C DUT, choose N67xx.

Page 9: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide 9

ValiFrame Station Configuration 2

DisplayPort

Figure 2 DisplayPort Station Configuration Wizard

For DisplayPort, you can choose between a Simple 5V Supply and Keysight N67xx Power Supply (Refer to Figure 2).

Page 10: Keysight N5990A Type-C Extension

10 Keysight N5990A Type-C Extension User Guide

2 ValiFrame Station Configuration

Thunderbolt

Figure 3 Thunderbolt Station Configuration Wizard

For Thunderbolt, you can choose between Keysight N67xx and a Simple 5V supply (Refer to Figure 3).

For details about the complete setup options, refer to the specific User Guide for each standard.

Remote Instruments Server

The Remote Instruments Server is a host server application. All information needed is packed into an installer. This installer also contains special USB driver libraries as well as the driver for N7018A.

When Type-C PDO testing is enabled, the N7018A Type-C Controller will be included in the Rx setup.

Page 11: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide 11

ValiFrame Station Configuration 2

The Remote Instruments Server is necessary to access the N7018A. It can be installed on any machine with a MS-Windows system like a PC, laptop or a Keysight DSO.

It allows connection via Ethernet to the USB port, where the N7018A is plugged in.

Download it from BitifEye's ftp-site, http://www.bitifeye.com/downloads/RemoteInstrumentsServer_1.6.exe install and run it the first time with admin rights.

If you also want to use the Unigraf AUX channel controller DPT-200 and/or the Artek CLE1000 for DisplayPort-tests, you can access them remotely through this RemoteInstrumentsServer.

Instrument Configuration

The last step of the Station Configuration is the Instrument Configuration. In this step, you have to enter instrument addresses.

For Keysight N7018A, use the address of the machine where the N7018A is connected to.

In the example below, the Remote Instrument Server is installed in the Keysight oscilloscope (Refer to Figure 4):

NOTEThe Remote Instrument Server must be installed in that machine.

Page 12: Keysight N5990A Type-C Extension

12 Keysight N5990A Type-C Extension User Guide

2 ValiFrame Station Configuration

Figure 4 Instrument Configuration with Remote Instrument Server installed in the Keysight Oscilloscope

If you have connected the N7018A to the same PC where ValiFrame is running, type in the local IP address “127.0.0.1” (Refer to Figure 5).

Figure 5 Instrument Configuration with Remote Instrument Server installed in the same PC as ValiFrame

Page 13: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide

3 ValiFrame DUT Configuration

USB / 14DisplayPort / 18Thunderbolt / 20PDO Configuration / 21

After the Station is configured, perform the following steps:

1 Open the ValiFrame software of the particular application.

2 From the main window of each active application, click Configure DUT to open the corresponding Configuration Dialog window.

In the Configuration Dialog Window, all test parameters can be configured, including the PDOs and other properties of the DUT's Type-C.

Page 14: Keysight N5990A Type-C Extension

14 Keysight N5990A Type-C Extension User Guide

3 ValiFrame DUT Configuration

USB

To select the PDOs, perform the following steps (Refer to Figure 6, Figure 7 and Figure 8):

1 In the Station Configuration window, select the Test Type-C PDOs option.

2 In the Configure DUT window, select 3.1 as the Spec Version and Type-C as the connector type.

3 Select ExpertMode and click Parameters

4 In the Common Tab of the Test Parameters Window, select Power Supply as the mode under Power-Automation and Keysight N7015A as the fixture under Type-C.

5 In the Rx Super Speed tab of the Test Parameters Window, set the Loopback Training Method to Warm Reset LTSSM. Setting the Mode under Power Automation to Power Supply and the Method under Loopback Training to WarmResetLTSSM ensures that the DUT is brought into loopback while testing Lane1 and Lane2 in a single (instead of one?) run.

6 Click Select PDOs. Refer to the section “PDO Configuration” on page 21 for more details.

Page 15: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide 15

ValiFrame DUT Configuration

Figure 6 USB PDO Selection

megagarw
Highlight
Page 16: Keysight N5990A Type-C Extension

16 Keysight N5990A Type-C Extension User Guide

3 ValiFrame DUT Configuration

Figure 7 PDO Selection - Test Parameters Window

megagarw
Highlight
Page 17: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide 17

ValiFrame DUT Configuration

Figure 8 PDO Selection Display Window

For a description of all the other test properties, please refer to section 4.2.3 of the "Keysight N5990A Test Automation Software Platform for USB" guide.

megagarw
Highlight
Page 18: Keysight N5990A Type-C Extension

18 Keysight N5990A Type-C Extension User Guide

3 ValiFrame DUT Configuration

DisplayPort

To select the PDOs follow the next steps (Refer to Figure 9):

1 Select the Support for Type-C PDOs option.

2 Select DPType-C as CTS Version.

3 Select Keysight N7015A as the Plug Fixture.

4 Set the Type-C PDO Configuration section. Refer to “PDO Configuration” on page 21 for more details.

Figure 9 DisplayPort PDO Selection

By default, the standard 4 lanes operation mode is selected. In this mode, 1, 2 or 4 DP lanes can be tested.

Page 19: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide 19

ValiFrame DUT Configuration

Select the Check Box for DP 2+2 mode to enable the 2+2 lane operation mode. In this mode, two lanes of the Type-C interface are dedicated to USB3.1 (the other two are DP lanes) (Refer to Figure 10).

Figure 10 DP 2+2 Mode Selected

For the description of other test properties, refer to section 2.3 of the "Keysight N5990A-155 Test Automation Software Platform for Display Port" guide.

Page 20: Keysight N5990A Type-C Extension

20 Keysight N5990A Type-C Extension User Guide

3 ValiFrame DUT Configuration

Thunderbolt

To select the PDOs, perform the following steps (Refer to Figure 11):

1 Select the Support for Type-C PDOs option in the Station Configuration.

2 Select Keysight N7015A Test Fixture as Fixture Type.

3 Click Select PDOs to configure PDOs. Refer to the section “PDO Configuration” on page 21 for more information.

Figure 11 Thunderbolt PDO Selection

For the description of all the other test properties please refer to the section 3.2 of the "Keysight N5990A-104 Test Automation Software Platform for Thunderbolt" guide.

Page 21: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide 21

ValiFrame DUT Configuration

PDO Configuration

In the PDO Selection dialog/section, you can read out the PDOs from the DUT and select such PDOs that must be applied during the RX tests.

Prior to reading the PDOs, it is necessary to configure the power supply. To do so, click Configure Power Supply (Refer to Figure 12).

Figure 12 PDO Power Supply Configuration

• If N67xx is used, the dialog shows the available channel modules of the N67xx frame. Here, you can choose the module to use (Refer to Figure 13).

• In case of a simple 5V power supply, the dialog shows the configured current capability. Here, you can type in the actual current capability of the power supply. For the 5V power supply, you may use a high-power USB plug-in charger (Refer to Figure 13).

Page 22: Keysight N5990A Type-C Extension

22 Keysight N5990A Type-C Extension User Guide

3 ValiFrame DUT Configuration

Figure 13 N67xx Power Module Configuration

After you have configured the power supply, click Read the DUT PDOs to query the PDOs from the DUT. The PDO list displays only those PDOs, which can be supported by the currently configured power supply. For example, a consumer PDO 5V/900mA will be not displayed, if your configured power supply is only capable of 5V/500mA. To view unsupported PDOs, uncheck the Only supported PDOs check box.

NOTEYou can only select supported PDOs for tests.

Page 23: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide 23

ValiFrame DUT Configuration

Figure 14 Supported PDO selection

In the same dialog, you can select the configuration channel to CC1 for normal connection orientation and to CC2 for flipped orientation.

If, for some reasons, you want to run tests with flipped SBU-lines, select the Flip SBU-lines check box. The SBU lines are assigned to AUX +/- in Displayport-mode and to LSTX / LSRX in Thunderbolt-mode in the right orientation, taking the CC into account (Refer to Figure 14).

Page 24: Keysight N5990A Type-C Extension

24 Keysight N5990A Type-C Extension User Guide

3 ValiFrame DUT Configuration

Page 25: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide

4 Connection Diagrams

USB / 26DisplayPort / 31Thunderbolt / 37

Page 26: Keysight N5990A Type-C Extension

26 Keysight N5990A Type-C Extension User Guide

4 Connection Diagrams

USB

Rx Tests with M8020A

Figure 15 Rx Tests with M8020A

1 Connect the DC blocking capacitors to the M8020A data outputs.

2 Connect the blocking capacitors to the Keysight N7015A Fixture data inputs.

3 Connect the Keysight N7015A Fixture to the Keysight N7018A Type-C Test Controller.

4 Connect the Keysight N7015A Fixture data outputs to the M8020A data inputs.

5 Connect the Keysight N7015A Fixture to the DUT.

Page 27: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide 27

Connection Diagrams

6 Connect the N67XX Modular Power System Mainframe to the Keysight N7018A Type-C Test Controller power input

7 Terminate all the connectors as indicated.

Page 28: Keysight N5990A Type-C Extension

28 Keysight N5990A Type-C Extension User Guide

4 Connection Diagrams

LFPS Rx Tests with M8020A

Figure 16 LFPS Rx Tests with M8020A

1 Connect the DC blocking capacitors to the M8020A data outputs.

2 Connect the blocking capacitors to the Keysight N7015A Fixture data inputs.

3 Connect the Keysight N7015A Fixture to the Keysight N7018A Type-C Test Controller.

4 Connect the positive output of the Keysight N7015A Fixture to Oscilloscope Channel 1.

5 Connect the negative output of the Keysight N7015A Fixture to M8020A SYS IN A.

6 Connect M8020A Trig Out+ to Oscilloscope Channel 3.

7 Connect the Keysight N7015A Fixture to the DUT.

8 Connect the N67XX Modular Power System Mainframe to the Keysight N7018A Type-C Test Controller power input.

9 Terminate all the connectors as indicated.

Page 29: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide 29

Connection Diagrams

Rx Tests with N4903B

Figure 17 Rx Tests with N4903B

1 Connect N4903B Data Out+ to N4916 De-Emphasis Signal Converter Data In.

2 Connect N4903B Aux CLK Out to N4916 De-Emphasis Signal Converter CLK In.

3 Connect two DC blocking capacitors to the N4916 De-Emphasis Signal Converter data outputs.

4 Connect the blocking capacitors to the Keysight N7015A Fixture data inputs.

5 Connect the Keysight N7015A Fixture to the Keysight N7018A Type-C Test Controller.

Page 30: Keysight N5990A Type-C Extension

30 Keysight N5990A Type-C Extension User Guide

4 Connection Diagrams

6 Connect the Keysight N7015A Fixture data outputs to the N4903B data inputs.

7 Connect the Keysight N7015A Fixture to the DUT.

8 Connect the N67XX Modular Power System Mainframe to the Keysight N7018A Type-C Test Controller power input.

9 Terminate all the connectors as indicated.

Page 31: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide 31

Connection Diagrams

DisplayPort

Rx Tests with M8020A

Figure 18 Rx Tests with M8020A

1 Use DC Blocks for victim aggressor lane.

2 TTCs for the victim lane: 60ps (Picoseconds Pulse Labs).

3 TTCs for the aggressor lanes: 150ps (Picoseconds Pulse Labs).

Page 32: Keysight N5990A Type-C Extension

32 Keysight N5990A Type-C Extension User Guide

4 Connection Diagrams

4 Use 3-way power dividers to generate the signals from the aggressor generator.

5 Terminate all the unused outputs of the signal generator with 50 Ohm.

Page 33: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide 33

Connection Diagrams

Rx Tests with N4903B

Figure 19 Rx Tests with N4903B

1 Use the DC Blocks for victim aggressor lane.

2 TTCs for the victim lane: 60ps Picoseconds Pulse Labs.

3 TTCs for the aggressor lanes: 150ps Picoseconds Pulse Labs.

4 Use 3-way power dividers to generate the signals from the aggressor generator.

5 Terminate all the unused outputs of the signal generator with 50 Ohm.

Page 34: Keysight N5990A Type-C Extension

34 Keysight N5990A Type-C Extension User Guide

4 Connection Diagrams

Rx Tests with ParBERT 7G

Figure 20 Rx Tests with ParBERT 7G

1 Use the DC Blocks for victim agressor lane.

2 TTCs for the victim lane: 60ps Picoseconds Pulse Labs.

3 TTCs for the aggressor lanes: 150ps Picoseconds Pulse Labs.

4 Use 3-way power dividers to generate the signals from the aggressor generator.

5 Terminate all the unused outputs of the signal generator with 50 Ohm.

Page 35: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide 35

Connection Diagrams

Rx Tests for DP 2+2 mode

Figure 21 Rx Tests for DP 2+2 mode

1 Use the DC Blocks for victim agressor lane.

2 TTCs for the victim lane: 60ps Picoseconds Pulse Labs.

3 TTCs for the aggressor lanes: 150ps Picoseconds Pulse Labs.

Page 36: Keysight N5990A Type-C Extension

36 Keysight N5990A Type-C Extension User Guide

4 Connection Diagrams

4 Use 3-way power dividers to generate the signals from the aggressor generator.

5 Terminate two of the power divider outputs with 50 Ohm.

6 Terminate all the unused outputs of the signal generator with 50 Ohm.

Page 37: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide 37

Connection Diagrams

Thunderbolt

Rx TP2 Tests with M8020A

Figure 22 Rx TP2 Tests with M8020A

1 Connect the N5171B EXG output to the M8062A CM input 'INTERFERENCE IN / CM'.

2 Use the DC-blocking caps at the M8062A outputs.

3 Connect the M8062A data outputs to the lane under test of the fixture. The lane under test is 'Rx0'.

Page 38: Keysight N5990A Type-C Extension

38 Keysight N5990A Type-C Extension User Guide

4 Connection Diagrams

4 Connect the TBT fixture to the PortA/PortB of the DUT

5 Use the same cables and accessories that were connected for calibration. Do not disconnect them between calibrations and tests.

Page 39: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide 39

Connection Diagrams

Rx TPEQ Tests with M8020A

Figure 23 Rx TPEQ Tests with M8020A

1 Connect the N5171B EXG output to the M8062A CM input 'INTERFERENCE IN / CM'.

2 Use DC-blocking caps at the M8062A outputs.

3 Connect the M8062A data outputs to the lane under test of the fixture. The lane under test is 'Tx0'.

4 Connect the TBT fixture to the PortA/PortB of the DUT.

5 Use a Thunderbolt Type-C cable of 2m between the TBT fixture and the DUT.

6 Use the same cables and accessories that were connected for calibration. Do not disconnect them between calibrations and tests.

Page 40: Keysight N5990A Type-C Extension

40 Keysight N5990A Type-C Extension User Guide

4 Connection Diagrams

Page 41: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide

5 Calibration Procedures

References / 42

Page 42: Keysight N5990A Type-C Extension

42 Keysight N5990A Type-C Extension User Guide

5 Calibration Procedures

References

The calibration procedures for USB, Display Port and Thunderbolt Type-C are the same as for the respective technology standards.

Refer to the base manual of the particular application to get relevant information about calibrating your setup:

• Section 4.5.1 of the Keysight N5990A Test Automation Software Platform for USB.

• Chapter 5 of the Keysight N5990A-155 Test Automation Software Platform for DisplayPort.

• Section 5.1 of the Keysight N5990A-104 Test Automation Software Platform for Thunderbolt.

Page 43: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide

6 Rx Test Procedures

PDO Iterations Node / 44

Page 44: Keysight N5990A Type-C Extension

44 Keysight N5990A Type-C Extension User Guide

6 Rx Test Procedures

PDO Iterations Node

When at least one PDO has been selected, there will be an additional node in the test tree. This is the PDO iterations node that will contain all the receiver test procedures (Refer to Figure 24).

Page 45: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide 45

Rx Test Procedures 6

Figure 24 PDO Iterations Node

If you select the PDO iterations node, the property panel will display information of all the selected PDOs and some configurable parameters:

• Do Auto Iterations through the PDO list?: If set to true, each selected PHY test will be done with each of the selected PDOs applied to the DUT.

Page 46: Keysight N5990A Type-C Extension

46 Keysight N5990A Type-C Extension User Guide

6 Rx Test Procedures

The procedure is the same as that for other tests (Refer to Figure 25):

1 Select the desired set of PHY tests and start the sequencer, following which ValiFrame will automatically repeat each test for each PDO.

Figure 25 Test Selection and Execution

2 Save a Workbook after each PDO step?: If set to true, for each PDO, the set of test results is saved in an HTML-workbook (Refer to Figure 26).

3 Path for auto-saved Workbooks: Set the location of the saved workbook.

Page 47: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide 47

Rx Test Procedures 6

Figure 26 Test Results

The PDO handling method is the same for all standards (that is, USB, DP and Thunderbolt).

The list of Rx tests is not affected by the selection of the PDOs. Refer to the base manual of the particular application to get relevant information about them:

• Section 4.5.2 of the Keysight N5990A Test Automation Software Platform for USB.

• Chapter 6 of the Keysight N5990A-155 Test Automation Software Platform for Display Port.

• Section 5.2 of the Keysight N5990A-104 Test Automation Software Platform for Thunderbolt.

Page 48: Keysight N5990A Type-C Extension

48 Keysight N5990A Type-C Extension User Guide

6 Rx Test Procedures

Page 49: Keysight N5990A Type-C Extension

Keysight N5990A Type-C Extension User Guide

7 Contact Information

For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus.

Page 50: Keysight N5990A Type-C Extension

50 Keysight N5990A Type-C Extension User Guide

7 Contact Information

Page 51: Keysight N5990A Type-C Extension

Keysight ValiFrame Type C Extension User Guide 51

Page 52: Keysight N5990A Type-C Extension

This information is subject to change without notice.© Keysight Technologies 2017December 30, 2017

www.keysight.com