65
KEYGOE INSTALLATION & CONFIGURATION (SS7) (Keygoe ver 2.2.0) Table of contents 1.0 Introduction..........................................3 2.0 Keygoe Installation...................................3 2.1 Installation procedure...............................3 3.0 Keygoe SS7 Configuration..............................9 3.1 SS7 Configuration procedure..........................9 4.0 Demo Program Configuration...........................57 4.1 Procedure to run Demo program.......................61 1

Keygoe_SS7

Embed Size (px)

Citation preview

Page 1: Keygoe_SS7

KEYGOE INSTALLATION & CONFIGURATION (SS7)

(Keygoe ver 2.2.0)

Table of contents

1.0 Introduction..................................................................................................................32.0 Keygoe Installation......................................................................................................3

2.1 Installation procedure.............................................................................................33.0 Keygoe SS7 Configuration..........................................................................................9

3.1 SS7 Configuration procedure.................................................................................94.0 Demo Program Configuration..................................................................................57

4.1 Procedure to run Demo program.........................................................................61

1

Page 2: Keygoe_SS7

1.0 Introduction

This document will describe step by step procedure to configure Keygeo for SS7 Enviorment.

2.0 Keygoe Installation2.1 Installation procedure

To install run Keygoe V2.2.0.exe

2

Page 3: Keygoe_SS7

Step 1

Step 2: Click “OK” to continue

Step 3

3

Page 4: Keygoe_SS7

Step 4: Click “Next” to continue.

Step 5: Click “Next” to continue.

4

Page 5: Keygoe_SS7

Step 6: Click “Next” to continue.

Step 7: (No need to select (I need am originally ini files) if Keygoe installed first time)

5

Page 6: Keygoe_SS7

Step 8: Need not to select Setting Local Config.

Step 9

6

Page 7: Keygoe_SS7

Step 10: Set the local machine IP address and click “Set” to continue.

Step 11: Click “OK” to continue.

Step 12: Click “Finish” to restart the machine.

7

Page 8: Keygoe_SS7

3.0 Keygoe SS7 Configuration3.1 SS7 Configuration procedure

Go to C:/DJKeygoe/bin and open “ITPCFGIPSET.exe”.

8

Page 9: Keygoe_SS7

Enable “Local IP” and Set “Config server IP” as a local IP.

Click “OK” to continue.

Go to C:/DJKeygoe/bin and open “Config.bat”, it will run and close automatically.

9

Page 10: Keygoe_SS7

Go to C:/DJKeygoe/bin and open “DJITPConfigServer.exe”, it will run and close automatically.

10

Page 11: Keygoe_SS7

Go to C:/DJKeygoe/bin and open “DJITPInterFaceCM.exe”.

11

Page 12: Keygoe_SS7

Click “Settings” Icon.

Set machine IP address and click “OK” to continue.

12

Page 13: Keygoe_SS7

If “Keygoe system (Machine IP)” is not appears in the screen then click “Refresh” icon button.

Right click “keygoe system (machine IP)” go to “Add unit (R)” and go to “DSP (D)” and choose “search DSP (S)” for adding DSP.

13

Page 14: Keygoe_SS7

Select “Chassis 1” to precede the configuration.

14

Page 15: Keygoe_SS7

Select “Slot1” and select “DSP0” and Set “IP address” in the same subnet of machine IP.

Click “OK” to continue.

Note: Follow the above step for adding all DSP’s.

If DSP has not shown in above “Find DSP module” screen, follow this step: Right click “keygoe system (machine IP)” and go to “Add unit (R)” and go to “DSP (D)” and choose “add directly (D)” for adding DSP directly using MAC ID.

15

Page 16: Keygoe_SS7

Set “MAC ID”( Note down the MAC ID from back side of the E1 card) and Set “IP address” in the same subnet of machine IP.

Click “OK” to continue.

16

Page 17: Keygoe_SS7

If the DSP’s are added correctly then the screen appears like this.

Right click “DSP” and click “Update firmware (G).

17

Page 18: Keygoe_SS7

Click browse button and choose the file from c:\DJKeygoe\Bin.

Choose (c:\DJKeygoe\Bin) “ITP1200C_R000020EL” and click “open” to continue

Choose the file and click “Begin to load”. This screen shows the updating the DSP firmware.

18

Page 19: Keygoe_SS7

Click “OK” to continue

DSP must be reloaded after changing any configuration on DSP module

For DSP reload Right Click on DSP > select Reload DSP.

Right click “keygoe system (machine IP)” go to “Add unit” and click “Flow (F)”.

19

Page 20: Keygoe_SS7

Be sure that both (Keygoe application IP & Flow module IP) are same.

Click “OK” to continue.

20

Page 21: Keygoe_SS7

If Flow module is added correctly the screen appears like this.

Right click “keygoe system (Machine IP)” and go to “Add unit” and click “Media”.

21

Page 22: Keygoe_SS7

Be sure that both (Keygoe application IP & Media module IP) are same.

Click “OK” to continue.

22

Page 23: Keygoe_SS7

Right click “keygoe system (Machine IP)” and go to “Add unit” and click “SS7 (S)”.

23

Page 24: Keygoe_SS7

Be sure that both (Keygoe application IP & SS7 module IP) are same.

Click “OK” to continue.

24

Page 25: Keygoe_SS7

Click “Start all keygoe units” icon for starting all units.

If all units are added correctly the screen appears like this.Click “Stop all keygoe units” icon for stopping the units.

25

Page 26: Keygoe_SS7

Click “Yes” to stop all keygoe units.

This screen shows all the units are stop.

Note: If keygoe units are not come green color, follow this step’s:Go to C:/DJKeygoe/bin and open “Remove server.bat” for stopping the all units.Go to C:/DJKeygoe/bin and open “Start server.bat” for starting the all units.

26

Page 27: Keygoe_SS7

Flow the steps for Associate “Flow, Media & SS7” units with DSP Right click “DSP” and click “Associate unit (R)”.

Add 3 “Associate module type” by Clicking “Create” button for associate the “Flow, Media & SS7”.

27

Page 28: Keygoe_SS7

Expand all the modules.

28

Page 29: Keygoe_SS7

Set Module type “Flow, Media & SS7” and click “Set” to continue.

Click “OK” to continue.

29

Page 30: Keygoe_SS7

Go to “Flow0” and double click the “common Set”.

Expand “CT Bus resource configuration item”.

30

Page 31: Keygoe_SS7

In “CT Bus resource configuration item” expand “0” and modify the “Chassis ID” from 0 to 1 and click “Set” to continue.

Click “OK” to continue.

31

Page 32: Keygoe_SS7

Right click “Media 0” and click “Associate unit (R)”.

Add 1 “Associate module type” by clicking the “Create” button for associate with “Flow”.

32

Page 33: Keygoe_SS7

Change “Module type” as “Flow module”.

Click “OK” to continue.

33

Page 34: Keygoe_SS7

Right click “SS70” and click “Associate unit (R)”.

Add 1 “Associate module type” by clicking the “Create” button for associate with “Flow”.

34

Page 35: Keygoe_SS7

Change “Module type” as “Flow module”.

Click “OK” to continue.

35

Page 36: Keygoe_SS7

Go to C:/DJKeygoe/bin and double click the “Remove server.bat” for stop the Keygoe service.

36

Page 37: Keygoe_SS7

Go to C:/DJKeygoe/bin and double click the “Start server.bat” for start the Keygoe service.

This screen shows all the units are working fine.

37

Page 38: Keygoe_SS7

Expand “DSP” and expand the “Run Config” and double click the “Global Config”.

38

Page 39: Keygoe_SS7

Expand the “Digital interface configuration”.

39

Page 40: Keygoe_SS7

In “Digital interface configuration” expand “0” and set the Digital interface type as “E1-30(1 SS7-ISUP link)” and click “Set” to continue.

Note: Set the timeslot as per MSC configuration.

If signal timeslot is 16, config “SS7 link 1 timeslot” is 16 and “SS7 link 2 timeslot” is 0.In SS7 one link will support 20 E1’s. Make sure with MSC guys for this E1 & link.

40

Page 41: Keygoe_SS7

For second E1, if there is no link has to define, set the Digital interface type as “E1-30(0 SS7-ISUP link)”

Click “OK” to continue.

41

Page 42: Keygoe_SS7

Expand the “SS70” and again expand the “MTP3 parameter” then double-click the “Config mode”.

In SS7X expand the “MTP3 parameter” and double-click the “config mode”.

42

Page 43: Keygoe_SS7

Change the “Configuration mode” from “easy mode” to “standard mode” and click “Set” to continue.

Click “OK” to continue.

Right click “SS7X” click “stop unit (S)” to stop the SS7 unit.

43

Page 44: Keygoe_SS7

Right click “SS7X” click “start unit (S)” to start the SS7 unit.

Expand the “Parameter config” to config the Standard mode parameters.

44

Page 45: Keygoe_SS7

Double click the “SAP parameter”.

Select the “Several source” and click “OK” to continue.

45

Page 46: Keygoe_SS7

Change the “Link type” parameter as “CCITT” and “SPC Length” as “CCITT blue book-14bit” in ISUP parameter.

Click “OK” to continue.

46

Page 47: Keygoe_SS7

Double click the “Route Parameter”.

Select “Several source” and click “OK” to continue.

47

Page 48: Keygoe_SS7

By default “Switch type” is “CHINA”.

Change “Switch type” from “CHINA” to “CCITT”

48

Page 49: Keygoe_SS7

Enable the two routes first for Inbound and Second for out bound, set the vales of DPC and OPC as per Switch then select SET button.

Click “OK” to continue.

Double click the “Link set parameter”.

49

Page 50: Keygoe_SS7

Select “Several source” and click “OK” to continue.

Check whether “DPC” value is set or not and click “Set” to continue.

50

Page 51: Keygoe_SS7

Click “OK” to continue.

Double click the “Link parameter”.

51

Page 52: Keygoe_SS7

Select “Several Source” and click “OK” to continue.

Set the values corresponding to DPC, OPC, LINK type, SLC, SSF.

Then Set these parameters.

52

Page 53: Keygoe_SS7

Right click the “SS7x” and click “stop unit (S)” to stop the SS7 unit.

Right click the “SS7x” and click “start unit (B)” to start the SS7 unit.

53

Page 54: Keygoe_SS7

Expand “DSPx” and expand “State info” and double click the “E1port state”.

Select “several source” and click “OK” to continue.

54

Page 55: Keygoe_SS7

Check alarm state, if “alarm” means E1 is not up. If “non-alarm” means E1 is up.“Receive signal voltage” “0dB” means E1 is up and “-12dB” means E1 is not up.

Double click the “MTP2 link state”.

55

Page 56: Keygoe_SS7

Select “Several source” and click “OK” to continue.

Check “Link status”, it should be in “In_Service”.

If “Link status” is “Out_of_Service” or “Initial_Alignment” means link is not up.

56

Page 57: Keygoe_SS7

For checking the link status, go to “Status & statistic” and click the “Link status” it will show the status “Link is working”.

4.0 Demo Program Configuration4.1 Procedure to run Demo program

Go to C:\DJKeygoe\Samples\XMS_Demo and open the XMS_Demo.INI.

57

Page 58: Keygoe_SS7

Change IP address to Keygoe IP and set “Partwork” is 1 and set “PartworkmoduleID” is 1.Partwork = 0 means DSP is not enable.Partwork = 1 means DSP is enable.

PartworkmoduleID = 1 means DSP0.PartworkmoduleID = 2 means DSP1.PartworkmoduleID = 3 means DSP2.

Run XMS_Demo.exe for testing the Inbound.

58

Page 59: Keygoe_SS7

This screen shows the inbound call is landing.

Go to C:\DJKeygoe\Samples\XMS_Demo and open the XMS_Dial.INI.

59

Page 60: Keygoe_SS7

Change IP address to Keygoe IP and set “Partwork” is 1 and set “PartworkmoduleID” is 1.Partwork = 0 means DSP is not enable.Partwork = 1 means DSP is enable.

PartworkmoduleID = 1 means DSP0.PartworkmoduleID = 2 means DSP1.PartworkmoduleID = 3 means DSP2.

Run XMS_Dial.exe for testing the Outbound.

60

Page 61: Keygoe_SS7

This screen shows the outbound call is landing.

61