8
MADE IN GERMANY COMBIVERT R6 Supply and Regenerative Systems

KEB | КЕБ - R6en).pdf · 2014. 3. 26. · 4 KEB COMBIVERT R6 ˜ NCM ˜ Technical data Art.-No. 15.R6.N1E-900A 19.R6.N1E-900A 19.R6.N1E-910A Housing size E Mains phases 3 Rated

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

  • MADE IN GERMANY

    COMBIVERT R6R6R6

    Supply and Regenerative Systems

  • 2

    R6-NCMNatural Current Modulation

    KEB COMBIVERT R6 -NCM - Philosophy

    The kinetic energy of electric drives represents unused energy potential which - from a historical point of view - was „destroyed“ by friction loss or mechanical/electrical braking devices.Dynamic and e� ciency-optimised AC drives and servo systems with increased e� ciency create high productivity and lead to higher regenerative loads.

    In combination with a regenerative unit the same frequency inverter and servo drive o� er the possibility of converting the energy, stored in the DC circuit, back into the main line power supply.

    Now the system produces useful output power in the mains instead of „waste heat“ for the nearby environment.

    The KEB COMBIVERT R6-NCM regenerative units are designed to supply and regenerate energy of one or more parallel drive controllers, and can be cascaded in any manner depending on the drive or regenerative capacity.

    Saving energy through regeneration -

    an environmental contribution that pays o� !

    Contents PagePhilosophy 2Application examples 3Simpli� ed diagrams 3Technical data 4EMC � lters / Chokes / Harmonic � lters 5System properties 6Voltage / Current diagram 7Addresses 8

  • 3L3L2L1

    L3L2L1

    R6 F5

    R6 F5

    Applications - Simpli� ed diagram

    Passenger lifts cargo elevators compensation of braking resistors reduced � re risk may be amortised over a period of two years

    of operating time

    Feed into the grid with choke (block-shaped) or with harmonic � lter (sinus-shaped) conform

    to EN 12015 and EN 61000-3-12 for energy generation facilities (sizes 15/19) THDi < 8 %

    - combustion engines cogeneration - small wind turbines - biogas facilities - hydro-electric plants

    Eccentric loads improved e� ciency factor active regenerative braking

    Theatre technology no heating up of nearby environment energy optimisation no additional noise during braking

    Lifting and conveyor systems / Storage technology power supply in DC-system with energy

    exchange peak load is returned to mains no additional heat source

    Test branches and test systems permanent regeneration of energy can be cascaded for large loads braking of large centrifugal masses

    Centrifuges utilisation of kinetic energy higher availability due to short start-up and run-down times

    Simpli� ed diagram with commutation choke

    Simpli� ed diagram with harmonic � lter

    With KEB COMBILINE harmonic � lters, the R6-NCM systems create a sinus-shaped return feed and current draw from the grid.

  • 4

    KEB COMBIVERT R6 - NCM - Technical data

    Art.-No. 15.R6.N1E-900A 19.R6.N1E-900A 19.R6.N1E-910AHousing size EMains phases 3Rated voltage [V] 400 (230)Input voltage range [V] 180…550+ 0 %Mains frequency [Hz] 50 / 60 + 2Regenerative operationOutput rated voltage [kVA] 18 (10.5) 45 (26)Rated active power [kW] 17 (10) 42 (23)Max. power output [kVA] 27 (15,5) 67.5 (39) 81 (46,6)Max. active power [kW] 25.5 (15) 63 (34.5) 75 (42)Regenerative rated current [A] 26 65Regenerative DC current [ADC] 32 80Overload current (E.OL) 60 s [A] 39 97,5 117[10s]Max. regenerative DC current 60 s [ADC] 48 120 144 [10s]Power supply operationInput rated power [kVA] 18 (10.5) 48,5 (28)Rated active power [kW] 16 (10) 44.5 (25.5)Max. input power [kVA] 27 (15.5) 72.5 (42) 87 (50) [10s]Max. active power [kW] 24 (14.5) 67 (38) 80 (46) [10s]Input supply current [A] 26 70DC supply current [ADC] 32 87Overload current (E.OL) 60 s [A] 39 105 126 [10s]Max. DC supply current 60 s [ADC] 48 130 156 [10s]Overload disconnection [%] 160 160 200DC-fuse internal optional (N3E) -Dimensions (W x H x D) [mm] 130x290x208Weight [kg] 5.6 5.6

    * Bracket values obtain for operations at 230 V power supply.

    To ensure the connection to the system control, KEB COMBIVERT R6-NCM features � exible serial communication and freely programmable analog / digital inputs and outputs.

    Freely programmable inputs and outputs4 x digital IN2 x digital OUT2 x relay OUT1 x analog OUT

    Supply and regenerative units 15.R6.N1E-900A 19.R6.N1E-900A 19.R6.N1E-910ADuty cycle 72% 100% 81% 100% 86% 100%EMC Filter 14.E6.T60-3000 16.E6.T60-3000 18.E6.T60-3000 20.E6.T60-3000 18.E6.T60-3000 20.E6.T60-3000Choke 15.Z1.B04-1000 19.Z1.B04-1000 20.Z1.B04-1000 20.Z1.B04-1000Harmonic � lter 15.Z1.C04-1000 19.Z1.C04-1000 20.Z1.C04-1000 20.Z1.C04-1000

    Assignment of � lters and chokes / harmonic � lters depending on the duty cycle

    W

    D

    H

    Supply and regenerative units

    W

    D

    H

  • 5

    Filter and chokes

    Chokes

    Bloc

    k-sh

    aped

    fe

    ed b

    ack

    Art.-No. 15.Z1.B04-1000 19.Z1.B04-1000 20.Z1.B04-1000Nominal current [A] 26 63 79Power dissipation [W] 86 142 168Dimensions (WxHxD) [mm] 178 x 87 x 180 219 x 135 x 220 219 x 150 x 220Weight [kg] 1.8 3.7 3.8

    Sine

    wav

    e fe

    ed ba

    ck

    Art.-No. 15.Z1.C04-1000 19.Z1.C04-1000 20.Z1.C04-1000THD 8%Nominal current [A] 25.2 63 79Power dissipation [W] 190 420 430Dimensions (WxHxD) [mm] 291 x 214 x 257 352 x 355 x 326 388 x 296 x 360Weight [kg] 25.5 63 72.6

    EMC � lters

    Size 15.R6. 19.R6.Art.-No. 00.90.147-3500 00.90.147-4101

    Art.-No. 14.E6.T60-3000 16.E6.T60-3000 18.E6.T60-3000 20.E6.T60-3000Nominal current [A] 22 43 65 100Power dissipation [W] 13.5 17.5 27 54Leakage current [mA]

  • 6

    M

    R6

    R6

    F5

    MF5

    R6

    M

    M

    M

    F5

    F5

    F5

    R6

    PF5 < PR6

    PF5 > PR6

    M

    R6 F5

    KEB COMBIVERT R6 -NCM - Connection types

    Feed-in / DC - FU

    AC feed-in parallel

    AC feed-in modular

    Parallel mains connection of converter and regenerative system

    In applications with a smaller proportion of energy return feeds, power can be supplied to drive controller in parallel. To prevent feed-in of the regeneration unit, we use decoupling diodes.

    installation always with decoupling diodes choke installation xx.Z1.F04-1010 (in line with inverter size), with uk=1% in

    front the inverter

    Supply and regeneration with central mains connection

    The connected drive controllers are supplied through the DC input and the braking energy is fed back into the mains.

    scalable input for the DC connection of converters and servo drives integrated pre-charging for the DC system the complete system: Devices EMC-Filter EN 61800-3, Class C1 - C3 choke or harmonic � lter

    Parallel operation of several R6-NCM units

    In large-power applications, parallel mounted regenerative systems feed back the energy.

    compact and modular design for optimum system integration or retro� tting of existing systems

    integrated DC fuses in sizes 15. and 19.R6.N3E reduce external wiring high overall e� ciency factor ensures optimum use of kinetic energy

  • 7

    Voltage / Current diagram for regenerative operation

    � rst and second generation of serial communication solutions

    Current with main chokeVoltage Current with harmonic � lter

    General properties

    suitable for all established 3 phase supply voltages of 200 V … 500 V AC, 50/60 Hz

    optional integrated DC fuses reduce external wiring and installation costs

    display of current feed-in, return feed output and energy meter

    digital control and serial connection to system control with …

  • Karl E. Brinkmann GmbH Försterweg 36 - 38 • D - 32683 Barntrup Telefon +49 5263 401-0 • Telefax 401-116Internet: www.keb.de • E-Mail: [email protected]

    © KEB 00.00.000-52R6 / 09-2013 • Subject to technical alterations!

    Headquarters

    COMPANIES

    KEB Antriebstechnik GmbH • Geared MotorsWildbacher Straße 5 • D - 08289 SchneebergTelefon +49 3772 67-0 • Telefax 67-281Internet: www.keb-drive.de • E-Mail: [email protected]

    AUSTRIAKEB AntriebstechnikAustria GmbHRitzstraße 8A - 4614 MarchtrenkTel: +43 7243 53586-0Fax: +43 7243 53586-21E-mail: [email protected]: www.keb.at

    CHINAKEB Power TransmissionTechnology (Shanghai) Co. Ltd.No. 435 QianPu RoadSongjiang East Industrial ZoneCN-201611 Shanghai, PR. ChinaTel: +86 21 37746688Fax: +86 21 37746600E-mail: [email protected]: www.keb.cn

    FRANCESociété Française KEBZ.I. de la Croix St. Nicolas14, rue Gustave Ei� elF - 94510 LA QUEUE EN BRIETel: +33 149620101Fax: +33 145767495E-mail: [email protected]: www.keb.fr

    GREAT BRITAINKEB (UK) Ltd.Morris ClosePark Farm Industrial EstateGB - WellingboroughNN8 6 XFTel: +44 1933 402220Fax: +44 1933 400724E-mail: [email protected]: www.keb-uk.co.uk

    ITALYKEB Italia S.r.l. UnipersonaleVia Newton, 2I - 20019 Settimo Milanese (Milano)Tel: +39 02 3353531Fax: +39 02 33500790E-mail: [email protected]: www.keb.it

    JAPANKEB - Japan Ltd.15 - 16, 2 - ChomeTakanawa Minato-kuJ - Tokyo 108 - 0074Tel: +81 33 445-8515Fax: +81 33 445-8215E-mail: [email protected]: www.keb.jp

    RUSSIAKEB CIS ZAOLesnaya str, house 30Dzerzhinsky (MO)RUS - 140091 Moscow regionTel: +7 495 6320217Fax: +7 495 6320217E-Mail: [email protected]: www.keb.ru

    USAKEB America, Inc5100 Valley Industrial Blvd. SouthUSA - Shakopee, MN 55379Tel: +1 952 2241400 Fax: +1 952 2241499E-mail: [email protected]: www.kebamerica.com

    Representative o� ces• Belgium• Brazil• Korea• Sweden• Spain

    Further partners for …

    Australia • Belgium • Bulgaria • Czech Republic • Denmark • Egypt • Greece • Hungary • India • Indonesia • Iran • Israel • Malaysia • Morocco • Netherlands • New Zealand • Pakistan • Poland • Portugal • Romania • Singapore • Slovakia • South Africa • Spain • Sweden • Switzerland • Taiwan • Thailand • Tunisia • Turkey • Uzbekistan

    … under www.keb.de/en/contact/keb-worldwide.html