KCI Instrument Cable Catalogue 1390.Bak.bak

  • Upload
    zara60

  • View
    44

  • Download
    0

Embed Size (px)

Citation preview

  • KC

    I

  • Contents

    An Introduction to Kerman & Kavian Cable Industries (KCI)

    Instrument Cables according to IEC 60092-376

    Instrument Cables according to EN 50288-7

    IEC 60092-376 ; Cable Construction Requirements

    Appendixes

    IEC EN 50288-7 ; Cable Construction Requirements

    Rated Voltage 150/250 (300) V

    Rated Voltage 500 V

    RE-2X(St)Y RE-2X(St)H

    RE-YCY RE-2XCH

    RE-2X(St)YQY

    Low Smoke , Halogen free Type :

    Low Smoke , Halogen free Type :

    RE-2X(St)HQH

    RE-2X(St)HQHRE-2X(St)YQY Fire Resistant

    Fire Resistant

    Fire Resistant

    Fire Resistant

    Fire Resistant Fire Resistant

    Fire Resistant

    Fire Resistant

    Fire Resistant

    Fire Resistant

    RE-Y(St)Y RE-2X(St)H

    RE-2X(St)Y RE-2X(St)H

    RE-Y(St)YRY

    RE-Y(St)YBY

    RE-2X(St)YRY

    RE-2X(St)YBY

    RE-2X(St)HRH

    RE-2X(St)HBH

    RE-2X(St)HRH

    RE-2X(St)HBH

    RE-Y(St)YRY , ..iMFY RE-2X(St)HRH , ..iMFH

    RE-Y(St)YKYRY

    RE-2X(St)YKYRY

    Cable protection against noise & Screen selection

    RE-2X(St)HKHRH

    RE-2X(St)HKHRH

    RE-2X(St)(L)2Y4YRY RE-2X(St)(L)2Y4YRH

    Page : 13

    Page : 35

    Page : 57

    Page : 79

    Page : 107

    Page : 129

    Page : 151

    Page : 173

    Page : 183

    Page : 205

    Page : 227

    Page : 249

    Page : 271

    Page : 293

    Page : 314

  • KCI

    4

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    KERMAN CABLE INDUSTRIES (KCI)

    KERMAN CABLE INDUSTRIES (KCI) was established in 1984 by co-operation of a team of experts in

    industrial estate no.1 of Kerman. In the first phase, KCI had 5000 m2 production area in the land having 20000

    m2 for manufacturing several types of cables.

    In the second phase, KCI increased the production area to 20000 m2 in the land having area of 60000 m2.

    KCI is active in the field of cable production with modern European machinery and with 400 personnel. The

    nominal production capacity of the factory is 13600 metric tons of cable products per year.

    As there are considerable sources of cables main raw materials

    (such as copper, pvc, steel, lead,) in IRAN and in the other side

    there are huge requirements of wire and cable in IRAN , KERMAN

    CABLE INDUSTRIES (KCI) was established by a team of experts

    in technical, research and quality control matters .

    KCI have modern European machinery and well equipped

    laboratories. Manufacturing coaxial cables for TV, CATV, Electronic

    industry and data communication and computer networks,

    military purposes, mobile and telecommunication centers was the

    outstanding point of KCIs innovative activities.

    The development of manufacturing lines have been continued by

    production of telephone , switchboard cables for telecommunication

    , flexible and shielded control cables , instrument cables , power low

    voltage cables , submersible pump wires , wires for automobiles

    , LAN cable , railway signalling cables , according to special

    requirements of corresponding projects up to now .

    Most types of mentioned products have been manufactured for the

    first time in IRAN which were qualified according to international

    test methods and complied with all related projects requirements.

    KCI has cooperated with many national and international projects

    such as power stations and substations, petrochemical plants, oil and

    gas refineries, cement factories, railway, in supply of different

    types of required cables.

    In addition to continuous innovations, the management has specially emphasized on the quality of products

    and services. KCI has certificate of ISO 9001-2000 quality system, national standard and special approvals

    from international laboratories such as Warrington fire(in England). Also KCIs QC laboratory has granted

    as accredited laboratory of institute standard of IRAN and can test cables on behalf of them. KCI is a well

    known company in top brand of cable manufacturers in IRAN and majority of companies active in different

    branches of industries have KCI in their approved vendor lists. Recently KCI received merit award from

    OIEC Company that was active in phase 9 & 10 of south pars gas field development project, because of on

    time delivery and high quality of the cables to that site. Considering above matters and daily needs of our

    industries to cable products, KCI has continuous development plans to comply the newest requirements of

    those projects.

  • 5Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    KAVIAN CABLE INDUSTRIES (KCI)

    In order to accomplish main expansion phase of Kerman Cable Industries and by having the background of

    30 years experiment in cable industry, KAVIAN CABLE INDUSTRIES(KCI) was established in 1996 in

    KAVEH industrial estate (near to SAVEH city). KCI has 17000 m2 of production area in the land having area

    of 90000 m2. KCI now is active in the field of cable production with modern European machinery and with

    100 personnel. The nominal production capacity of the factory is 17000 metric tons of cable products per year.

    As there are considerable sources of cables main raw materials

    (such as copper, pvc, steel, lead,) in IRAN and in the other side

    there are huge requirements of wire and cable in IRAN , KAVIAN

    CABLE INDUSTRIES (KCI) was established by a team of experts

    in technical, research and quality control matters .

    KCI have modern European machinery and well equipped

    laboratories. Also in order to accomplish main expansion phase

    of Kerman cable factory that new machinery and technology in

    new area seemed to be necessary. So management of the company

    decided to establish new factory in order to fulfill major part of each

    projects required cables.

    The new brand of products was telephone cables up to 2400 pairs,

    power cable up to 630 mm2 with copper and aluminium conductor

    , lead sheathed cables for refineries and similar projects , aerial

    power cables , medium voltage cables up to 30kV and being single

    or multi core , that all of mentioned cables could be armoured by

    steel/aluminium wires or tapes.

    All of mentioned cable types have been designed according to

    international updated standards which were qualified in tests and

    complied with all related projects requirements.

    KCI has cooperated with many national and international projects

    such as power stations and substations, petrochemical plants, oil and

    gas refineries, cement factories, railway, in supply of several types

    of required cables.

    In addition to continuous innovations, the management has specially

    emphasized on the quality of products and services.

    KCI special approvals from international laboratories such as

    KEMA (in Netherlands) and Warrington fire (in England).

  • Kerman & Kavian Cable Industries ( KCI )

  • KCI

    Cables for control and instrumentation circuits 150/250 V (300 V)

    According to of IEC 60092-376 (2003)

    Electrical installations in ships - Part 376:

  • KCI

    8

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Scope and object :

    This part of IEC 60092 is applicable to screened and unscreened cables for control and instrumentation

    circuits on ships and offshore units.

    The cables have extruded solid insulation with a voltage rating of 150/250V (300V) and are intended

    for fixed installations.

    1 ) Conductors :

    The material, metal coating, separator, class and form of the conductors shall be in accordance with IEC

    60092-350 and shall be circular Class 2 or Class 5 constructions of cross-sectional area

    0.50 mm2, 0.75 mm2, 1.0 mm2, 1.5 mm2 or 2.5 mm2.

    Note : The preferred conductor sizes are 0.75 mm2 and 1.5 mm2.

    A Summary of IEC 60092-376 (2003)

    Electrical installations in ships - Part 376:

    Cables for control and instrumentation circuits 150/250 V (300 V)

    Rated voltage :

    The standard rated voltage Uo/U (Um) is as follows:

    UO/U (UM) = 150 V/250 V (300 V) a.c.

    In the voltage designation of cables ;

    UO : is the rated power-frequency voltage between the conductor and the earth or metallic covering

    for which the cable is designed;

    U : is the rated power-frequency voltage between conductors for which the cable is designed.

    UM : is the maximum value of the highest system voltage for which the equipment may be used.

    A d.c. voltage up to a maximum of 1.5 times the a.c. voltage may be used, provided that the voltage to

    earth does not exceed 250 V.

    Nominal cross

    section of

    conductors (mm2)

    Class 2 Stranding Class 5 Stranding

    DC resistance of (conductors)

    plain copper tinned copper plain copper tinned copper

    Ohm/kM at 20C

    0.5 40.4 41.6 41.4 42.5

    0.75 26 26.3 27.6 28.3

    1.0 19.2 19.3 20.7 21.2

    1.5 12.8 12.9 14.1 14.5

    2.5 7.86 8.02 8.47 8.71

  • 9Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    PVC : Poly vinyl chloride XLPE : Cross-linked Polyethylene

    2 ) Insulation system

    The insulation system shall consist of either;

    2-1 ) one of the insulating compounds indicated in following Table

    2-2) a combination of one or more layers of inorganic tape(s) and a layer of one of the insulating

    compounds indicated in following Table (example Mica-Glass Tape + XLPE )

    2-1) An Insulated Conductor 2-2) A Conductor Insulated by

    by Mica-glass and an extruded Insulation

    Nominal

    cross

    section of

    conductors

    PVC/A EPR XLPE HEPR HF 85 S 95

    mm2 mm mm mm mm mm mm

    0.5 0.6 0.6 0.4 0.4 0.6 0.6

    0.75 0.6 0.6 0.5 0.5 0.6 0.6

    1.0 0.6 0.6 0.5 0.5 0.6 0.6

    1.5 0.7 0.7 0.6 0.6 0.7 0.7

    2.5 0.7 0.7 0.6 0.6 0.7 0.7

    Used as insulation of Fire-Resistance Cables

  • KCI

    10

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    3 ) Cabling

    3-1 ) Core assembly (multicore cables)

    The individual cores shall be twisted together in concentric layers.

    3-2 ) Forming pair, triple or quad units ;

    Cores shall be twisted together with either a left hand or right hand lay to form a pair, triple or quad unit.

    The lay length of the cores individually or collectively screened shall not exceed 120 mm for sizes below

    1.5 mm2 and 150 mm for sizes 1.5 mm2 and above.

    4 ) Electrostatic screen

    4-1 ) Individually taped screened pair, triple or quad constructions

    When an individual taped screened pair, triple or quad construction is required, each pair, triple or quad

    shall have a laminated electrostatic screening tape applied with the metallic side in electrical contact with

    a drain wire. The nominal overlap shall not be less than 25 %.

    The laminated electrostatic screening tape shall be either aluminium bonded to polyester having a

    minimum thickness of aluminium of 0.008 mm and a minimum thickness of polyester of 0.010 mm, or

    copper bonded to polyester having a minimum thickness of copper of 0.018 mm and a minimum thickness

    of polyester of 0.023 mm.

    The drain wire shall be composed of a number of strands of tinned annealed copper wires in the case of

    aluminium laminate tape and either plain or tinned annealed copper wires in the case of copper laminate

    tape.The drain wire shall have a maximum resistance in accordance with following Table .

    Core (Unit) Pair (Unit) Triple (Unit)

    Unit element Wire a Wire b Wire c Wire d

    Pair unit Black White - -

    Triple unit Black White Red -

    Quad unit Black White Red Blue

    3-3 ) Typical colour code for single unit cables

    3-4 ) Number of cores

    It is recommended that the number of cores shall be selected from one of the following:

    2, 4, 7, 12, 19, 27, 37.

    3-5 ) Number of pair, triple or quad units

    It is recommended that the number of pair units shall be selected from one of the following:

    1, 3, 7, 12, 19, 27, 37.

    Triple (Unit) Individually Screened

    in Metallic Foil (TiMF)

    Pair (Unit) Individually Screened

    in Metallic Foil (PiMF)

  • 11

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    4-2 ) Individually braided screened pair, triple or quad constructions

    When an individual braided screened pair, triple or quad construction is required, each pair, triple or quad

    shall have a non-hygroscopic separator tape applied over the cores and under the braid.

    The nominal overlap shall not be less than 25 %.

    The braid shall be either plain or metal coated copper wires; the minimum diameter of the braid wire shall

    be: When required, to aid termination, a drain wire may be applied under and in direct contact with the braid

    screen.The drain wire shall be composed of a number of strands of tinned or plain annealed copper wires. The

    drain wire shall have a maximum resistance in accordance with following Table .

    Nominal cross section

    of conductors

    Maximum drain wire

    resistance

    mm2 Ohm/km

    0.5 61.2

    0.75 42.5

    1.0 28.3

    1.5 28.3

    2.5 21.2

    Braid (Screen)

    Static Tape (Screen)

    4-3 ) Collectively screened constructions

    Similar to 4-1) and 4-2) ; both taped and braided screens type is permitted .

    5 ) Metal braid armour

    In this standard the braid wires are either:

    zinc coated (galvanised) steel , or

    copper (plain or tinned),

    Note : In the case of plain or tinned copper wire braids, these may also provide the function of an electrostatic

    collective screen providing they are terminated to earth.

    Zinc coated (galvanized)

    Steel wires Braid

    Plain Copper wires

    Braid

    Tinned Plain Copper

    wires Braid

    6 ) Sheath(s)

    Could be one of following materials ; PVC , PE , Halogen Free .

    The sheath shall be coloured black or grey unless otherwise specified.

    Note : The sheath may be of other colours, thereby providing a visual difference to

    that of LV and MV Power cables.

  • Kerman & Kavian Cable Industries ( KCI )

  • KCI

    RE-2X(St)Y

    RE-2X(St)H

    RE-2X(St)Y Multi-Core

    RE-2X(St)H Multi-Core

    RE-2X(St)Y Multi-Pair

    RE-2X(St)H Multi-Pair

    RE-2X(St)Y Multi-Triple

    RE-2X(St)H Multi-Triple

    RE-2X(St)Y PiMF

    RE-2X(St)H PiMF

    RE-2X(St)Y TiMF

    RE-2X(St)H TiMF

    IEC 60092-376 150/250 V (300 V)

    Alternatively ; Low Smoke , Halogen free Type :

  • KCI

    14

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Conductor Stranded (class 2) Plain annealed copper wires

    Insulation XLPE

    Cable Unit Core (Multi-Core Cable)

    Collective (Overall )

    Screen

    Polyester tape + Drain wire (Tinned copper) +

    Al.Polyester Tape

    Outer Sheath Extruded PVC

    RE-2X(St)Y

    Criteria Standard Values Unit

    Conductor cross section Nominal 0.5 0.75 1 1.5 2.5 mm

    Conductor DC Resistance

    @ 20oCmax. 40.4 26 19.2 12.8 7.86 Ohm/kM

    Insulation resistance min. 1000MOhm x

    km

    Mutual capacitance max. 150 nF/km

    L/R (ratio) max. 25 25 25 40 60microH/

    Ohm

    Test voltage :

    for 5

    minutes 1.5 kV A.C K.V core to core

    core to screen

    Operating voltage U(rms) 300 V

    Color Coding (Options) :

    Black (Numbered) Yellow or White (Numbered)

    IEC 60092-376 150/250 V (300 V)

    7.5x O.D+90 oC IEC 60332-1 Screened

  • 15

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 0.5 mm2 (7x0.3 mm)

    2x0.5 0.4 1.0 5.7 48 1000

    3x0.5 0.4 1.0 6.0 56 1000

    4x0.5 0.4 1.0 6.4 64 1000

    5x0.5 0.4 1.0 6.9 73 1000

    6x0.5 0.4 1.0 7.4 82 1000

    7x0.5 0.4 1.0 7.4 88 1000

    8x0.5 0.4 1.1 8.6 103 1000

    10x0.5 0.4 1.1 9.3 119 1000

    12x0.5 0.4 1.1 9.6 133 1000

    16x0.5 0.4 1.1 10.5 163 1000

    20x0.5 0.4 1.2 11.7 199 1000

    24x0.5 0.4 1.2 12.9 231 1000

    30x0.5 0.4 1.3 13.8 278 1000

    Conductor : 0.75 mm2 (7x0.37 mm)

    2x0.75 0.5 1.0 6.5 59 1000

    3x0.75 0.5 1.0 6.8 70 1000

    4x0.75 0.5 1.0 7.4 83 1000

    5x0.75 0.5 1.0 8.0 95 1000

    6x0.75 0.5 1.1 8.8 112 1000

    7x0.75 0.5 1.1 8.8 121 1000

    8x0.75 0.5 1.1 10.1 138 1000

    10x0.75 0.5 1.2 11.1 166 1000

    12x0.75 0.5 1.2 11.5 187 1000

    16x0.75 0.5 1.2 12.6 232 1000

    20x0.75 0.5 1.3 14.1 284 1000

    24x0.75 0.5 1.3 15.5 331 1000

    30x0.75 0.5 1.4 16.6 401 1000

    RE-2X(St)YIEC 60092-376 150/250 V (300 V)

  • KCI

    16

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 1.0 mm2 (7x0.43 mm)

    2x1 0.5 1.0 6.9 61 1000

    3x1 0.5 1.0 7.2 75 1000

    4x1 0.5 1.0 7.8 90 1000

    5x1 0.5 1.1 8.7 109 1000

    6x1 0.5 1.1 9.4 125 1000

    7x1 0.5 1.1 9.4 138 1000

    8x1 0.5 1.1 10.7 157 1000

    10x1 0.5 1.2 11.8 192 1000

    12x1 0.5 1.2 12.2 219 1000

    16x1 0.5 1.2 13.5 275 1000

    20x1 0.5 1.3 15.1 339 1000

    24x1 0.5 1.3 16.6 398 1000

    30x1 0.5 1.4 17.8 485 1000

    Conductor : 1.5 mm2 (7x0.53 mm)

    2x1.5 0.6 1.0 7.9 78 1000

    3x1.5 0.6 1.1 8.5 103 1000

    4x1.5 0.6 1.1 9.2 125 1000

    5x1.5 0.6 1.1 10.0 148 1000

    6x1.5 0.6 1.1 10.9 171 1000

    7x1.5 0.6 1.1 10.9 189 1000

    8x1.5 0.6 1.2 12.7 223 1000

    10x1.5 0.6 1.3 14.0 272 1000

    12x1.5 0.6 1.3 14.5 312 1000

    16x1.5 0.6 1.3 16.0 395 1000

    20x1.5 0.6 1.4 18.0 488 1000

    24x1.5 0.6 1.5 20.0 584 1000

    30x1.5 0.6 1.5 21.2 702 1000

    RE-2X(St)YIEC 60092-376 150/250 V (300 V)

  • 17

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 2.5 mm2 (7x0.67 mm)

    2x2.5 0.6 1.1 8.9 108 1000

    3x2.5 0.6 1.1 9.4 138 1000

    4x2.5 0.6 1.1 10.3 171 1000

    5x2.5 0.6 1.2 11.4 209 1000

    6x2.5 0.6 1.2 12.3 242 1000

    7x2.5 0.6 1.2 12.3 270 1000

    8x2.5 0.6 1.3 14.4 316 1000

    10x2.5 0.6 1.3 15.7 380 1000

    12x2.5 0.6 1.3 16.2 438 1000

    16x2.5 0.6 1.4 18.2 569 1000

    20x2.5 0.6 1.5 20.4 703 1000

    24x2.5 0.6 1.6 22.7 840 1000

    30x2.5 0.6 1.6 24.1 1017 1000

    RE-2X(St)Y

    Additional Options (by request)

    Reduced smoke PVC

    Tested acc to ASTM E662 &

    Improved Flame Retardant

    acc to IEC 60332-3

    UV Resistant PVC Sheath

    Acc to UL 1581-1200

    Oil & Chemical

    Resistant PVC Sheath

    Acc to ICEA S-82-552

    (Equal to NEMA WC55)

    Low smoke

    Acc to IEC 61034

    Low Halogen Acid & Gas

    acc to IEC 60754-1&2

    IEC 60502 ST8

    A) Based on PVC Sheath

    B) Based on Halogen Free Construction Cable Type : RE-2X(St)H

    IEC 60092-376 150/250 V (300 V)

  • KCI

    18

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Conductor Stranded (class 2) Plain annealed copper wires

    Insulation XLPE

    Cable Unit Pair (Multi-Pair Cable)

    Collective (Overall )

    Screen

    Polyester tape + Drain wire (Tinned copper) +

    Al.Polyester Tape

    Outer Sheath Extruded PVC

    RE-2X(St)Y

    Criteria Standard Values Unit

    Conductor cross section Nominal 0.5 0.75 1 1.5 2.5 mm

    Conductor DC Resistance

    @ 20oCmax. 40.4 26 19.2 12.8 7.86 Ohm/kM

    Insulation resistance min. 1000MOhm x

    km

    Mutual capacitance max. 150 nF/km

    L/R (ratio) max. 25 25 25 40 60microH/

    Ohm

    Test voltage :

    for 5

    minutes 1.5 kV A.C K.V core to core

    core to screen

    Operating voltage U(rms) 300 V

    Color Coding (Options) :

    Black,White (Numbered) Black,Blue (Numbered) IEC 60708 Full color

    IEC 60092-376 150/250 V (300 V)

    7.5x O.D+90 oC IEC 60332-1 Screened

  • 19

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 0.5 mm2 (7x0.3 mm)

    1x2x0.5 0.4 1.0 5.7 49 1000

    2x2x0.5 0.4 1.0 7.9 72 1000

    3x2x0.5 0.4 1.1 8.5 91 1000

    4x2x0.5 0.4 1.1 9.2 108 1000

    5x2x0.5 0.4 1.1 10.0 125 1000

    6x2x0.5 0.4 1.1 10.9 142 1000

    7x2x0.5 0.4 1.1 10.9 155 1000

    10x2x0.5 0.4 1.3 14.0 221 1000

    12x2x0.5 0.4 1.3 14.5 249 1000

    16x2x0.5 0.4 1.3 16.0 309 1000

    20x2x0.5 0.4 1.4 17.9 379 1000

    24x2x0.5 0.4 1.5 20.0 451 1000

    30x2x0.5 0.4 1.5 21.2 535 1000

    Conductor : 0.75 mm2 (7x0.37 mm)

    1x2x0.75 0.5 1.0 6.5 60 1000

    2x2x0.75 0.5 1.1 9.4 97 1000

    3x2x0.75 0.5 1.1 10.0 119 1000

    4x2x0.75 0.5 1.1 10.9 143 1000

    5x2x0.75 0.5 1.2 12.0 174 1000

    6x2x0.75 0.5 1.2 13.1 199 1000

    7x2x0.75 0.5 1.2 13.1 218 1000

    10x2x0.75 0.5 1.4 16.9 312 1000

    12x2x0.75 0.5 1.4 17.5 355 1000

    16x2x0.75 0.5 1.5 19.6 453 1000

    20x2x0.75 0.5 1.5 21.7 547 1000

    24x2x0.75 0.5 1.6 24.3 652 1000

    30x2x0.75 0.5 1.7 25.9 790 500

    RE-2X(St)YIEC 60092-376 150/250 V (300 V)

  • KCI

    20

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 1.0 mm2 (7x0.43 mm)

    1x2x1 0.5 1.0 6.9 61 1000

    2x2x1 0.5 1.1 10.0 106 1000

    3x2x1 0.5 1.1 10.6 134 1000

    4x2x1 0.5 1.2 11.8 169 1000

    5x2x1 0.5 1.2 12.8 201 1000

    6x2x1 0.5 1.2 14.0 232 1000

    7x2x1 0.5 1.2 14.0 257 1000

    10x2x1 0.5 1.4 18.1 371 1000

    12x2x1 0.5 1.4 18.7 424 1000

    16x2x1 0.5 1.5 20.9 547 1000

    20x2x1 0.5 1.6 23.5 675 1000

    24x2x1 0.5 1.7 26.2 806 500

    30x2x1 0.5 1.7 27.8 967 500

    Conductor : 1.5 mm2 (7x0.53 mm)

    1x2x1.5 0.6 1.0 7.9 79 1000

    2x2x1.5 0.6 1.2 11.8 145 1000

    3x2x1.5 0.6 1.2 12.6 187 1000

    4x2x1.5 0.6 1.2 13.8 232 1000

    5x2x1.5 0.6 1.3 15.2 284 1000

    6x2x1.5 0.6 1.3 16.6 330 1000

    7x2x1.5 0.6 1.3 16.6 368 1000

    10x2x1.5 0.6 1.5 21.6 529 1000

    12x2x1.5 0.6 1.5 22.3 609 1000

    16x2x1.5 0.6 1.6 25.0 789 500

    20x2x1.5 0.6 1.7 28.1 974 500

    24x2x1.5 0.6 1.9 31.5 1178 500

    30x2x1.5 0.6 1.9 33.4 1420 500

    RE-2X(St)YIEC 60092-376 150/250 V (300 V)

  • 21

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 2.5 mm2 (7x0.67 mm)

    1x2x2.5 0.6 1.1 8.9 109 1000

    2x2x2.5 0.6 1.2 13.2 194 1000

    3x2x2.5 0.6 1.3 14.3 262 1000

    4x2x2.5 0.6 1.3 15.6 328 1000

    5x2x2.5 0.6 1.4 17.3 402 1000

    6x2x2.5 0.6 1.4 18.9 469 1000

    7x2x2.5 0.6 1.4 18.9 526 1000

    10x2x2.5 0.6 1.6 24.5 755 500

    12x2x2.5 0.6 1.7 25.6 886 500

    16x2x2.5 0.6 1.8 28.6 1149 500

    20x2x2.5 0.6 1.9 32.1 1419 500

    24x2x2.5 0.6 2.0 35.9 1694 500

    30x2x2.5 0.6 2.1 38.2 2072 500

    RE-2X(St)Y

    Additional Options (by request)

    Reduced smoke PVC

    Tested acc to ASTM E662 &

    Improved Flame Retardant

    acc to IEC 60332-3

    UV Resistant PVC Sheath

    Acc to UL 1581-1200Oil & Chemical

    Resistant PVC Sheath

    Acc to ICEA S-82-552

    (Equal to NEMA WC55)

    Low smoke

    Acc to IEC 61034

    Low Halogen Acid & Gas

    acc to IEC 60754-1&2

    IEC 60502 ST8

    A) Based on PVC Sheath

    B) Based on Halogen Free Construction Cable Type : RE-2X(St)H

    IEC 60092-376 150/250 V (300 V)

  • KCI

    22

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Conductor Stranded (class 2) Plain annealed copper wires

    Insulation XLPE

    Cable Unit Triple (Multi-Triple Cable)

    Collective (Overall )

    Screen

    Polyester tape + Drain wire (Tinned copper) +

    Al.Polyester Tape

    Outer Sheath Extruded PVC

    RE-2X(St)Y

    Criteria Standard Values Unit

    Conductor cross section Nominal 0.5 0.75 1 1.5 2.5 mm

    Conductor DC Resistance

    @ 20oCmax. 40.4 26 19.2 12.8 7.86 Ohm/kM

    Insulation resistance min. 1000MOhm x

    km

    Mutual capacitance max. 150 nF/km

    L/R (ratio) max. 25 25 25 40 60microH/

    Ohm

    Test voltage :

    for 5

    minutes 1.5 kV A.C K.V core to core

    core to screen

    Operating voltage U(rms) 300 V

    Color Coding (Options) :

    Black,White,Red (Numbered) Blue,White,Red (Numbered)

    IEC 60092-376 150/250 V (300 V)

    7.5x O.D+90 oC IEC 60332-1 Screened

  • 23

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 0.5 mm2 (7x0.3 mm)

    1x3x0.5 0.4 1.0 6.0 56 1000

    2x3x0.5 0.4 1.1 8.8 93 1000

    3x3x0.5 0.4 1.1 9.3 115 1000

    4x3x0.5 0.4 1.1 10.2 138 1000

    5x3x0.5 0.4 1.2 11.3 167 1000

    6x3x0.5 0.4 1.2 12.2 192 1000

    7x3x0.5 0.4 1.2 12.2 211 1000

    10x3x0.5 0.4 1.3 15.6 294 1000

    12x3x0.5 0.4 1.3 16.1 335 1000

    16x3x0.5 0.4 1.4 18.0 430 1000

    20x3x0.5 0.4 1.5 20.2 528 1000

    24x3x0.5 0.4 1.6 22.5 630 1000

    30x3x0.5 0.4 1.6 23.8 753 1000

    Conductor : 0.75 mm2 (7x0.37 mm)

    1x3x0.75 0.5 1.0 6.8 71 1000

    2x3x0.75 0.5 1.1 10.4 122 1000

    3x3x0.75 0.5 1.2 11.2 159 1000

    4x3x0.75 0.5 1.2 12.2 194 1000

    5x3x0.75 0.5 1.2 13.3 230 1000

    6x3x0.75 0.5 1.3 14.7 272 1000

    7x3x0.75 0.5 1.3 14.7 301 1000

    10x3x0.75 0.5 1.4 18.9 422 1000

    12x3x0.75 0.5 1.5 19.7 493 1000

    16x3x0.75 0.5 1.5 21.8 624 1000

    20x3x0.75 0.5 1.6 24.5 769 500

    24x3x0.75 0.5 1.7 27.3 918 500

    30x3x0.75 0.5 1.8 29.2 1118 500

    RE-2X(St)YIEC 60092-376 150/250 V (300 V)

  • KCI

    24

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 1.0 mm2 (7x0.43 mm)

    1x3x1 0.5 1.0 7.2 76 1000

    2x3x1 0.5 1.1 11.0 136 1000

    3x3x1 0.5 1.2 11.9 183 1000

    4x3x1 0.5 1.2 13.0 227 1000

    5x3x1 0.5 1.3 14.4 278 1000

    6x3x1 0.5 1.3 15.7 323 1000

    7x3x1 0.5 1.3 15.7 360 1000

    10x3x1 0.5 1.5 20.4 518 1000

    12x3x1 0.5 1.5 21.1 598 1000

    16x3x1 0.5 1.6 23.6 775 1000

    20x3x1 0.5 1.7 26.5 957 500

    24x3x1 0.5 1.8 29.6 1143 500

    30x3x1 0.5 1.8 31.3 1382 500

    Conductor : 1.5 mm2 (7x0.53 mm)

    1x3x1.5 0.6 1.0 8.3 100 1000

    2x3x1.5 0.6 1.2 13.1 190 1000

    3x3x1.5 0.6 1.2 13.9 252 1000

    4x3x1.5 0.6 1.3 15.5 323 1000

    5x3x1.5 0.6 1.4 17.2 396 1000

    6x3x1.5 0.6 1.4 18.7 463 1000

    7x3x1.5 0.6 1.4 18.7 520 1000

    10x3x1.5 0.6 1.6 24.3 746 1000

    12x3x1.5 0.6 1.6 25.2 865 500

    16x3x1.5 0.6 1.7 28.2 1125 500

    20x3x1.5 0.6 1.9 31.9 1405 500

    24x3x1.5 0.6 2.0 35.6 1679 500

    30x3x1.5 0.6 2.1 37.9 2053 500

    RE-2X(St)YIEC 60092-376 150/250 V (300 V)

  • 25

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 2.5 mm2 (7x0.67 mm)

    1x3x2.5 0.6 1.1 9.4 140 1000

    2x3x2.5 0.6 1.3 14.9 267 1000

    3x3x2.5 0.6 1.3 15.8 358 1000

    4x3x2.5 0.6 1.4 17.6 461 1000

    5x3x2.5 0.6 1.4 19.3 557 1000

    6x3x2.5 0.6 1.5 21.3 664 1000

    7x3x2.5 0.6 1.5 21.3 749 1000

    10x3x2.5 0.6 1.7 27.7 1073 500

    12x3x2.5 0.6 1.8 28.8 1264 500

    16x3x2.5 0.6 1.9 32.3 1646 500

    20x3x2.5 0.6 2.0 36.3 2037 500

    24x3x2.5 0.6 2.2 40.7 2452 500

    30x3x2.5 0.6 2.3 43.3 3007 500

    RE-2X(St)Y

    Additional Options (by request)

    Reduced smoke PVC

    Tested acc to ASTM E662 &

    Improved Flame Retardant

    acc to IEC 60332-3

    UV Resistant PVC Sheath

    Acc to UL 1581-1200

    Oil & Chemical

    Resistant PVC Sheath

    Acc to ICEA S-82-552

    (Equal to NEMA WC55)

    Low smoke

    Acc to IEC 61034

    Low Halogen Acid & Gas

    acc to IEC 60754-1&2

    IEC 60502 ST8

    A) Based on PVC Sheath

    B) Based on Halogen Free Construction Cable Type : RE-2X(St)H

    IEC 60092-376 150/250 V (300 V)

  • KCI

    26

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Conductor Stranded (class 2) Plain annealed copper wires

    Insulation XLPE

    Cable Unit Pair (Multi-Pair Cable)

    Individual Element

    Screen

    Polyester tape + Drain wire (Tinned copper) +

    Al.Polyester Tape + Polyester Tape

    Collective (Overall )

    Screen

    Polyester tape + Drain wire (Tinned copper) +

    Al.Polyester Tape

    Outer Sheath Extruded PVC

    Criteria Standard Values Unit

    Conductor cross section Nominal 0.5 0.75 1 1.5 2.5 mm

    Conductor DC Resistance

    @ 20oCmax. 40.4 26 19.2 12.8 7.86 Ohm/kM

    Insulation resistance min. 1000MOhm x

    km

    Mutual capacitance max. 150 nF/km

    L/R (ratio) max. 25 25 25 40 60microH/

    Ohm

    Test voltage :

    for 5

    minutes 1.5 kV A.C K.V core to core

    core to screen

    Operating voltage U(rms) 300 V

    Color Coding (Options) :

    Black,White (Numbered) Black,Blue (Numbered) IEC 60708 Full color

    RE-2X(St)Y , PiMF

    IEC 60092-376 150/250 V (300 V)

    7.5x O.D+90 oC IEC 60332-1 Screened

  • 27

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 0.5 mm2 (7x0.3 mm)

    1x2x0.5 0.4 1.0 6.0 66 1000

    2x2x0.5 0.4 1.1 9.2 113 1000

    3x2x0.5 0.4 1.1 9.7 145 1000

    4x2x0.5 0.4 1.1 10.6 178 1000

    5x2x0.5 0.4 1.2 11.7 216 1000

    6x2x0.5 0.4 1.2 12.7 251 1000

    7x2x0.5 0.4 1.2 12.7 279 1000

    10x2x0.5 0.4 1.3 16.3 391 1000

    12x2x0.5 0.4 1.4 17.0 458 1000

    16x2x0.5 0.4 1.4 18.8 584 1000

    20x2x0.5 0.4 1.5 21.1 720 1000

    24x2x0.5 0.4 1.6 23.5 860 1000

    30x2x0.5 0.4 1.6 24.9 1040 500

    Conductor : 0.75 mm2 (7x0.37 mm)

    1x2x0.75 0.5 1.0 6.9 78 1000

    2x2x0.75 0.5 1.1 10.6 136 1000

    3x2x0.75 0.5 1.2 11.5 181 1000

    4x2x0.75 0.5 1.2 12.5 222 1000

    5x2x0.75 0.5 1.2 13.7 265 1000

    6x2x0.75 0.5 1.3 15.1 314 1000

    7x2x0.75 0.5 1.3 15.1 350 1000

    10x2x0.75 0.5 1.4 19.4 492 1000

    12x2x0.75 0.5 1.5 20.2 576 1000

    16x2x0.75 0.5 1.6 22.6 745 1000

    20x2x0.75 0.5 1.7 25.4 918 500

    24x2x0.75 0.5 1.8 28.3 1096 500

    30x2x0.75 0.5 1.8 30.0 1323 500

    RE-2X(St)Y , PiMF

    IEC 60092-376 150/250 V (300 V)

  • KCI

    28

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 1.0 mm2 (7x0.43 mm)

    1x2x1 0.5 1.0 7.2 74 1000

    2x2x1 0.5 1.1 11.3 134 1000

    3x2x1 0.5 1.2 12.2 179 1000

    4x2x1 0.5 1.2 13.3 222 1000

    5x2x1 0.5 1.3 14.7 271 1000

    6x2x1 0.5 1.3 16.1 316 1000

    7x2x1 0.5 1.3 16.1 351 1000

    10x2x1 0.5 1.5 20.9 505 1000

    12x2x1 0.5 1.5 21.6 582 1000

    16x2x1 0.5 1.6 24.1 753 1000

    20x2x1 0.5 1.7 27.1 929 500

    24x2x1 0.5 1.8 30.2 1110 500

    30x2x1 0.5 1.9 32.2 1354 500

    Conductor : 1.5 mm2 (7x0.53 mm)

    1x2x1.5 0.6 1.0 8.2 92 1000

    2x2x1.5 0.6 1.2 13.2 177 1000

    3x2x1.5 0.6 1.3 14.3 238 1000

    4x2x1.5 0.6 1.3 15.7 295 1000

    5x2x1.5 0.6 1.4 17.3 362 1000

    6x2x1.5 0.6 1.4 18.9 422 1000

    7x2x1.5 0.6 1.4 18.9 471 1000

    10x2x1.5 0.6 1.6 24.6 677 500

    12x2x1.5 0.6 1.6 25.5 782 500

    16x2x1.5 0.6 1.8 28.7 1026 500

    20x2x1.5 0.6 1.9 32.2 1266 500

    24x2x1.5 0.6 2.0 36.0 1511 500

    30x2x1.5 0.6 2.1 38.3 1843 500

    RE-2X(St)Y , PiMF

    IEC 60092-376 150/250 V (300 V)

  • 29

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 2.5 mm2 (7x0.67 mm)

    1x2x2.5 0.6 1.1 9.3 126 1000

    2x2x2.5 0.6 1.3 14.9 240 1000

    3x2x2.5 0.6 1.3 15.9 317 1000

    4x2x2.5 0.6 1.4 17.7 407 1000

    5x2x2.5 0.6 1.4 19.4 490 1000

    6x2x2.5 0.6 1.5 21.4 583 1000

    7x2x2.5 0.6 1.5 21.4 654 1000

    10x2x2.5 0.6 1.7 27.8 938 500

    12x2x2.5 0.6 1.8 29.0 1102 500

    16x2x2.5 0.6 1.9 32.4 1430 500

    20x2x2.5 0.6 2.0 36.4 1767 500

    24x2x2.5 0.6 2.2 40.9 2128 500

    30x2x2.5 0.6 2.3 43.5 2601 500

    Additional Options (by request)

    Reduced smoke PVC

    Tested acc to ASTM E662 &

    Improved Flame Retardant

    acc to IEC 60332-3

    UV Resistant PVC Sheath

    Acc to UL 1581-1200

    Oil & Chemical

    Resistant PVC Sheath

    Acc to ICEA S-82-552

    (Equal to NEMA WC55)

    Low smoke

    Acc to IEC 61034

    Low Halogen Acid & Gas

    acc to IEC 60754-1&2

    IEC 60502 ST8

    A) Based on PVC Sheath

    B) Based on Halogen Free Construction Cable Type : RE-2X(St)H

    RE-2X(St)Y , PiMF

    IEC 60092-376 150/250 V (300 V)

  • KCI

    30

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Conductor Stranded (class 2) Plain annealed copper wires

    Insulation XLPE

    Cable Unit Triple (Multi-Triple Cable)

    Individual Element

    Screen

    Polyester tape + Drain wire (Tinned copper) +

    Al.Polyester Tape + Polyester Tape

    Collective (Overall )

    Screen

    Polyester tape + Drain wire (Tinned copper) +

    Al.Polyester Tape

    Outer Sheath Extruded PVC

    Criteria Standard Values Unit

    Conductor cross section Nominal 0.5 0.75 1 1.5 2.5 mm

    Conductor DC Resistance

    @ 20oCmax. 40.4 26 19.2 12.8 7.86 Ohm/kM

    Insulation resistance min. 1000MOhm x

    km

    Mutual capacitance max. 150 nF/km

    L/R (ratio) max. 25 25 25 40 60microH/

    Ohm

    Test voltage :

    for 5

    minutes 1.5 kV A.C K.V core to core

    core to screen

    Operating voltage U(rms) 300 V

    RE-2X(St)Y , TiMF

    Color Coding (Options) :

    Black,White,Red (Numbered) Blue,White,Red (Numbered)

    IEC 60092-376 150/250 V (300 V)

    7.5x O.D+90 oC IEC 60332-1 Screened

  • 31

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 0.5 mm2 (7x0.3 mm)

    1x3x0.5 0.4 1.0 6.3 74 1000

    2x3x0.5 0.4 1.1 10.1 131 1000

    3x3x0.5 0.4 1.1 10.7 169 1000

    4x3x0.5 0.4 1.2 11.9 215 1000

    5x3x0.5 0.4 1.2 12.9 256 1000

    6x3x0.5 0.4 1.3 14.2 304 1000

    7x3x0.5 0.4 1.3 14.2 339 1000

    10x3x0.5 0.4 1.4 18.2 476 1000

    12x3x0.5 0.4 1.4 18.8 549 1000

    16x3x0.5 0.4 1.5 21.1 712 1000

    20x3x0.5 0.4 1.6 23.7 879 1000

    24x3x0.5 0.4 1.7 26.4 1050 500

    30x3x0.5 0.4 1.7 28.0 1271 500

    Conductor : 0.75 mm2 (7x0.37 mm)

    1x3x0.75 0.5 1.0 7.2 89 1000

    2x3x0.75 0.5 1.2 11.9 167 1000

    3x3x0.75 0.5 1.2 12.7 217 1000

    4x3x0.75 0.5 1.2 13.9 270 1000

    5x3x0.75 0.5 1.3 15.4 330 1000

    6x3x0.75 0.5 1.4 16.9 392 1000

    7x3x0.75 0.5 1.4 16.9 437 1000

    10x3x0.75 0.5 1.5 21.8 616 1000

    12x3x0.75 0.5 1.6 22.7 722 1000

    16x3x0.75 0.5 1.7 25.4 935 500

    20x3x0.75 0.5 1.8 28.5 1153 500

    24x3x0.75 0.5 1.9 31.8 1377 500

    30x3x0.75 0.5 2.0 33.9 1682 500

    RE-2X(St)Y , TiMFIEC 60092-376 150/250 V (300 V)

  • KCI

    32

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 1.0 mm2 (7x0.43 mm)

    1x3x1 0.5 1.0 7.6 88 1000

    2x3x1 0.5 1.2 12.7 172 1000

    3x3x1 0.5 1.2 13.5 225 1000

    4x3x1 0.5 1.3 14.9 288 1000

    5x3x1 0.5 1.3 16.3 345 1000

    6x3x1 0.5 1.4 18.0 412 1000

    7x3x1 0.5 1.4 18.0 460 1000

    10x3x1 0.5 1.6 23.4 661 1000

    12x3x1 0.5 1.6 24.2 763 1000

    16x3x1 0.5 1.7 27.1 990 500

    20x3x1 0.5 1.8 30.4 1223 500

    24x3x1 0.5 1.9 34.0 1461 500

    30x3x1 0.5 2.0 36.2 1786 500

    Conductor : 1.5 mm2 (7x0.53 mm)

    1x3x1.5 0.6 1.1 8.9 118 1000

    2x3x1.5 0.6 1.3 14.9 231 1000

    3x3x1.5 0.6 1.3 15.8 305 1000

    4x3x1.5 0.6 1.4 17.6 391 1000

    5x3x1.5 0.6 1.4 19.3 471 1000

    6x3x1.5 0.6 1.5 21.3 561 1000

    7x3x1.5 0.6 1.5 21.3 629 1000

    10x3x1.5 0.6 1.7 27.7 903 500

    12x3x1.5 0.6 1.8 28.8 1060 500

    16x3x1.5 0.6 1.9 32.3 1375 500

    20x3x1.5 0.6 2.0 36.3 1699 500

    24x3x1.5 0.6 2.2 40.7 2047 500

    30x3x1.5 0.6 2.3 43.3 2502 500

    RE-2X(St)Y , TiMF

    IEC 60092-376 150/250 V (300 V)

  • 33

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 2.5 mm2 (7x0.67 mm)

    1x3x2.5 0.6 1.1 9.8 157 1000

    2x3x2.5 0.6 1.3 16.6 308 1000

    3x3x2.5 0.6 1.4 17.9 423 1000

    4x3x2.5 0.6 1.4 19.7 535 1000

    5x3x2.5 0.6 1.5 21.8 658 1000

    6x3x2.5 0.6 1.6 24.0 785 1000

    7x3x2.5 0.6 1.6 24.0 884 1000

    10x3x2.5 0.6 1.9 31.5 1281 500

    12x3x2.5 0.6 1.9 32.6 1491 500

    16x3x2.5 0.6 2.0 36.5 1941 500

    20x3x2.5 0.6 2.2 41.2 2420 500

    24x3x2.5 0.6 2.4 46.2 2911 500

    30x3x2.5 0.6 2.5 49.2 3565 500

    Additional Options (by request)

    Reduced smoke PVC

    Tested acc to ASTM E662 &

    Improved Flame Retardant

    acc to IEC 60332-3

    UV Resistant PVC Sheath

    Acc to UL 1581-1200

    Oil & Chemical

    Resistant PVC Sheath

    Acc to ICEA S-82-552

    (Equal to NEMA WC55)

    Low smoke

    Acc to IEC 61034

    Low Halogen Acid & Gas

    acc to IEC 60754-1&2

    IEC 60502 ST8

    A) Based on PVC Sheath

    B) Based on Halogen Free Construction Cable Type : RE-2X(St)H

    RE-2X(St)Y , TiMF

    IEC 60092-376 150/250 V (300 V)

  • Kerman & Kavian Cable Industries ( KCI )

  • KCI

    RE-YCY Multi-Pair

    RE-YCY Multi-Triple

    RE-YCY PiMF

    RE-YCY TiMF

    RE-YCY

    RE-2XCH

    RE-YCY Multi-Core

    RE-2XCH Multi-Core

    RE-2XCH Multi-Pair

    RE-2XCH Multi-Triple

    RE-2XCH PiMF

    RE-2XCH TiMF

    Alternatively ; Low Smoke , Halogen free Type :

    IEC 60092-376 150/250 V (300 V)

  • KCI

    36

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Conductor Stranded (class 2) Plain annealed copper wires

    Insulation PVC

    Cable Unit Core (Multi-Core Cable)

    Collective (Overall )

    ScreenBraid of Copper Wires

    Outer Sheath Extruded PVC

    RE-YCY

    Criteria Standard Values Unit

    Conductor cross section Nominal 0.5 0.75 1 1.5 2.5 mm

    Conductor DC Resistance

    @ 20oCmax. 40.4 26 19.2 12.8 7.86 Ohm/kM

    Insulation resistance min. 100MOhm x

    km

    Mutual capacitance max. 250 nF/km

    L/R (ratio) max. 25 25 25 40 60microH/

    Ohm

    Test voltage :

    for 5

    minutes 1.5 kV A.C K.V core to core

    core to screen

    Operating voltage U(rms) 300 V

    Color Coding (Options) :

    Black (Numbered) Yellow or White (Numbered)

    IEC 60092-376 150/250 V (300 V)

    7.5x O.D+70 oC IEC 60332-1 Screened

  • 37

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 0.5 mm2 (7x0.3 mm)

    2x0.5 0.6 1.0 7.0 65 1000

    3x0.5 0.6 1.0 7.4 76 1000

    4x0.5 0.6 1.0 7.9 91 1000

    5x0.5 0.6 1.1 8.7 110 1000

    6x0.5 0.6 1.1 9.3 123 1000

    7x0.5 0.6 1.1 9.3 131 1000

    8x0.5 0.6 1.1 10.6 151 1000

    10x0.5 0.6 1.2 11.6 178 1000

    12x0.5 0.6 1.2 12.0 198 1000

    16x0.5 0.6 1.2 13.3 266 1000

    20x0.5 0.6 1.3 14.8 324 1000

    24x0.5 0.6 1.4 16.4 377 1000

    30x0.5 0.6 1.4 17.3 443 1000

    Conductor : 0.75 mm2 (7x0.37 mm)

    2x0.75 0.6 1.0 7.4 73 1000

    3x0.75 0.6 1.0 7.8 91 1000

    4x0.75 0.6 1.1 8.6 109 1000

    5x0.75 0.6 1.1 9.3 129 1000

    6x0.75 0.6 1.1 9.9 148 1000

    7x0.75 0.6 1.1 9.9 160 1000

    8x0.75 0.6 1.2 11.5 185 1000

    10x0.75 0.6 1.2 12.7 233 1000

    12x0.75 0.6 1.2 13.1 266 1000

    16x0.75 0.6 1.3 14.5 328 1000

    20x0.75 0.6 1.3 16.0 392 1000

    24x0.75 0.6 1.4 17.7 466 1000

    30x0.75 0.6 1.4 18.9 577 1000

    RE-YCYIEC 60092-376 150/250 V (300 V)

  • KCI

    38

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 1.0 mm2 (7x0.43 mm)

    2x1 0.6 1.0 7.8 85 1000

    3x1 0.6 1.0 8.2 102 1000

    4x1 0.6 1.1 9.0 128 1000

    5x1 0.6 1.1 9.7 146 1000

    6x1 0.6 1.1 10.5 169 1000

    7x1 0.6 1.1 10.5 184 1000

    8x1 0.6 1.2 12.4 231 1000

    10x1 0.6 1.2 13.4 274 1000

    12x1 0.6 1.2 13.8 307 1000

    16x1 0.6 1.3 15.3 389 1000

    20x1 0.6 1.4 17.1 474 1000

    24x1 0.6 1.4 19.0 580 1000

    30x1 0.6 1.5 20.2 686 1000

    Conductor : 1.5 mm2 (7x0.53 mm)

    2x1.5 0.7 1.1 9.0 112 1000

    3x1.5 0.7 1.1 9.5 137 1000

    4x1.5 0.7 1.1 10.3 167 1000

    5x1.5 0.7 1.2 11.3 198 1000

    6x1.5 0.7 1.2 12.4 245 1000

    7x1.5 0.7 1.2 12.4 267 1000

    8x1.5 0.7 1.3 14.4 314 1000

    10x1.5 0.7 1.3 15.6 373 1000

    12x1.5 0.7 1.3 16.1 420 1000

    16x1.5 0.7 1.4 17.9 535 1000

    20x1.5 0.7 1.5 20.2 681 1000

    24x1.5 0.7 1.6 22.4 809 1000

    30x1.5 0.7 1.6 23.6 953 1000

    RE-YCYIEC 60092-376 150/250 V (300 V)

  • 39

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 2.5 mm2 (7x0.67 mm)

    2x2.5 0.7 1.1 9.8 141 1000

    3x2.5 0.7 1.1 10.4 176 1000

    4x2.5 0.7 1.2 11.5 218 1000

    5x2.5 0.7 1.2 12.7 275 1000

    6x2.5 0.7 1.2 13.7 320 1000

    7x2.5 0.7 1.2 13.7 352 1000

    8x2.5 0.7 1.3 15.9 412 1000

    10x2.5 0.7 1.4 17.5 502 1000

    12x2.5 0.7 1.4 18.0 570 1000

    16x2.5 0.7 1.5 20.3 755 1000

    20x2.5 0.7 1.6 22.6 926 1000

    24x2.5 0.7 1.6 24.9 1084 500

    30x2.5 0.7 1.7 26.5 1303 500

    Additional Options (by request)

    Reduced smoke PVC

    Tested acc to ASTM E662 &

    Improved Flame Retardant

    acc to IEC 60332-3

    UV Resistant PVC Sheath

    Acc to UL 1581-1200

    Oil & Chemical

    Resistant PVC Sheath

    Acc to ICEA S-82-552

    (Equal to NEMA WC55)

    Low smoke

    Acc to IEC 61034

    Low Halogen Acid & Gas

    acc to IEC 60754-1&2

    IEC 60502 ST8

    A) Based on PVC Sheath

    B) Based on Halogen Free Construction Cable Type : RE-2XCH

    RE-YCYIEC 60092-376 150/250 V (300 V)

  • KCI

    40

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Conductor Stranded (class 2) Plain annealed copper wires

    Insulation PVC

    Cable Unit Pair (Multi-Pair Cable)

    Collective (Overall )

    ScreenBraid of Copper Wires

    Outer Sheath Extruded PVC

    RE-YCY

    Criteria Standard Values Unit

    Conductor cross section Nominal 0.5 0.75 1 1.5 2.5 mm

    Conductor DC Resistance

    @ 20oCmax. 40.4 26 19.2 12.8 7.86 Ohm/kM

    Insulation resistance min. 100MOhm x

    km

    Mutual capacitance max. 250 nF/km

    L/R (ratio) max. 25 25 25 40 60microH/

    Ohm

    Test voltage :

    for 5

    minutes 1.5 kV A.C K.V core to core

    core to screen

    Operating voltage U(rms) 300 V

    Color Coding (Options) :

    Black,White (Numbered) Black,Blue (Numbered) IEC 60708 Full color

    IEC 60092-376 150/250 V (300 V)

    7.5x O.D+70 oC IEC 60332-1 Screened

  • 41

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 0.5 mm2 (7x0.3 mm)

    1x2x0.5 0.6 1.0 7.0 66 1000

    2x2x0.5 0.6 1.1 9.9 113 1000

    3x2x0.5 0.6 1.1 10.5 134 1000

    4x2x0.5 0.6 1.2 11.6 162 1000

    5x2x0.5 0.6 1.2 12.7 205 1000

    6x2x0.5 0.6 1.3 14.0 243 1000

    7x2x0.5 0.6 1.3 14.0 261 1000

    10x2x0.5 0.6 1.4 17.6 362 1000

    12x2x0.5 0.6 1.4 18.2 402 1000

    16x2x0.5 0.6 1.5 20.5 531 1000

    20x2x0.5 0.6 1.6 22.8 646 1000

    24x2x0.5 0.6 1.7 25.3 760 500

    30x2x0.5 0.6 1.7 26.7 883 500

    Conductor : 0.75 mm2 (7x0.37 mm)

    1x2x0.75 0.6 1.0 7.4 74 1000

    2x2x0.75 0.6 1.1 10.6 129 1000

    3x2x0.75 0.6 1.2 11.4 162 1000

    4x2x0.75 0.6 1.2 12.6 211 1000

    5x2x0.75 0.6 1.2 13.7 249 1000

    6x2x0.75 0.6 1.3 15.0 294 1000

    7x2x0.75 0.6 1.3 15.0 318 1000

    10x2x0.75 0.6 1.4 19.2 467 1000

    12x2x0.75 0.6 1.5 20.0 530 1000

    16x2x0.75 0.6 1.5 22.1 657 1000

    20x2x0.75 0.6 1.6 24.7 795 500

    24x2x0.75 0.6 1.7 27.4 944 500

    30x2x0.75 0.6 1.8 29.2 1120 500

    RE-YCYIEC 60092-376 150/250 V (300 V)

  • KCI

    42

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 1.0 mm2 (7x0.43 mm)

    1x2x1 0.6 1.0 7.8 86 1000

    2x2x1 0.6 1.1 11.2 145 1000

    3x2x1 0.6 1.2 12.3 203 1000

    4x2x1 0.6 1.2 13.3 247 1000

    5x2x1 0.6 1.3 14.7 298 1000

    6x2x1 0.6 1.3 15.9 337 1000

    7x2x1 0.6 1.3 15.9 367 1000

    10x2x1 0.6 1.5 20.6 548 1000

    12x2x1 0.6 1.5 21.3 614 1000

    16x2x1 0.6 1.6 23.7 779 1000

    20x2x1 0.6 1.7 26.4 946 500

    24x2x1 0.6 1.8 29.4 1125 500

    30x2x1 0.6 1.8 31.0 1327 500

    Conductor : 1.5 mm2 (7x0.53 mm)

    1x2x1.5 0.7 1.1 9.0 113 1000

    2x2x1.5 0.7 1.2 13.3 215 1000

    3x2x1.5 0.7 1.3 14.2 271 1000

    4x2x1.5 0.7 1.3 15.5 332 1000

    5x2x1.5 0.7 1.4 17.1 402 1000

    6x2x1.5 0.7 1.4 18.6 458 1000

    7x2x1.5 0.7 1.4 18.6 503 1000

    10x2x1.5 0.7 1.6 24.1 748 1000

    12x2x1.5 0.7 1.6 24.9 852 500

    16x2x1.5 0.7 1.7 27.7 1086 500

    20x2x1.5 0.7 1.9 31.2 1330 500

    24x2x1.5 0.7 2.0 34.7 1597 500

    30x2x1.5 0.7 2.1 36.9 1900 500

    RE-YCYIEC 60092-376 150/250 V (300 V)

  • 43

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 2.5 mm2 (7x0.67 mm)

    1x2x2.5 0.7 1.1 9.8 142 1000

    2x2x2.5 0.7 1.3 14.8 280 1000

    3x2x2.5 0.7 1.3 15.7 351 1000

    4x2x2.5 0.7 1.4 17.4 442 1000

    5x2x2.5 0.7 1.4 19.2 553 1000

    6x2x2.5 0.7 1.5 21.0 642 1000

    7x2x2.5 0.7 1.5 21.0 707 1000

    10x2x2.5 0.7 1.7 27.0 1003 500

    12x2x2.5 0.7 1.7 27.9 1157 500

    16x2x2.5 0.7 1.9 31.4 1483 500

    20x2x2.5 0.7 2.0 35.1 1828 500

    24x2x2.5 0.7 2.1 39.0 2154 500

    30x2x2.5 0.7 2.2 41.5 2595 500

    RE-YCY

    Additional Options (by request)

    Reduced smoke PVC

    Tested acc to ASTM E662 &

    Improved Flame Retardant

    acc to IEC 60332-3

    UV Resistant PVC Sheath

    Acc to UL 1581-1200

    Oil & Chemical

    Resistant PVC Sheath

    Acc to ICEA S-82-552

    (Equal to NEMA WC55)

    Low smoke

    Acc to IEC 61034

    Low Halogen Acid & Gas

    acc to IEC 60754-1&2

    IEC 60502 ST8

    A) Based on PVC Sheath

    B) Based on Halogen Free Construction Cable Type : RE-2XCH

    IEC 60092-376 150/250 V (300 V)

  • KCI

    44

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Conductor Stranded (class 2) Plain annealed copper wires

    Insulation PVC

    Cable Unit Triple (Multi-Triple Cable)

    Collective (Overall )

    ScreenBraid of Copper Wires

    Outer Sheath Extruded PVC

    RE-YCY

    Criteria Standard Values Unit

    Conductor cross section Nominal 0.5 0.75 1 1.5 2.5 mm

    Conductor DC Resistance

    @ 20oCmax. 40.4 26 19.2 12.8 7.86 Ohm/kM

    Insulation resistance min. 100MOhm x

    km

    Mutual capacitance max. 250 nF/km

    L/R (ratio) max. 25 25 25 40 60microH/

    Ohm

    Test voltage :

    for 5

    minutes 1.5 kV A.C K.V core to core

    core to screen

    Operating voltage U(rms) 300 V

    Color Coding (Options) :

    Black,White,Red (Numbered) Blue,White,Red (Numbered)

    IEC 60092-376 150/250 V (300 V)

    7.5x O.D+70 oC IEC 60332-1 Screened

  • 45

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 0.5 mm2 (7x0.3 mm)

    1x3x0.5 0.6 1.0 7.4 76 1000

    2x3x0.5 0.6 1.1 10.9 136 1000

    3x3x0.5 0.6 1.2 11.7 172 1000

    4x3x0.5 0.6 1.2 12.9 231 1000

    5x3x0.5 0.6 1.3 14.2 271 1000

    6x3x0.5 0.6 1.3 15.4 314 1000

    7x3x0.5 0.6 1.3 15.4 341 1000

    10x3x0.5 0.6 1.5 20.0 509 1000

    12x3x0.5 0.6 1.5 20.6 568 1000

    16x3x0.5 0.6 1.6 22.9 718 1000

    20x3x0.5 0.6 1.7 25.6 869 500

    24x3x0.5 0.6 1.8 28.4 1033 500

    30x3x0.5 0.6 1.8 30.0 1214 500

    Conductor : 0.75 mm2 (7x0.37 mm)

    1x3x0.75 0.6 1.0 7.8 91 1000

    2x3x0.75 0.6 1.2 11.9 164 1000

    3x3x0.75 0.6 1.2 12.8 224 1000

    4x3x0.75 0.6 1.3 14.1 281 1000

    5x3x0.75 0.6 1.3 15.3 332 1000

    6x3x0.75 0.6 1.4 16.8 393 1000

    7x3x0.75 0.6 1.4 16.8 429 1000

    10x3x0.75 0.6 1.5 21.5 628 1000

    12x3x0.75 0.6 1.6 22.4 717 1000

    16x3x0.75 0.6 1.6 24.8 891 500

    20x3x0.75 0.6 1.8 27.9 1104 500

    24x3x0.75 0.6 1.9 31.0 1298 500

    30x3x0.75 0.6 1.9 32.7 1538 500

    RE-YCYIEC 60092-376 150/250 V (300 V)

  • KCI

    46

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 1.0 mm2 (7x0.43 mm)

    1x3x1 0.6 1.0 8.2 103 1000

    2x3x1 0.6 1.2 12.7 206 1000

    3x3x1 0.6 1.2 13.5 263 1000

    4x3x1 0.6 1.3 14.9 330 1000

    5x3x1 0.6 1.3 16.2 385 1000

    6x3x1 0.6 1.4 17.8 456 1000

    7x3x1 0.6 1.4 17.8 501 1000

    10x3x1 0.6 1.6 23.1 743 1000

    12x3x1 0.6 1.6 23.8 840 1000

    16x3x1 0.6 1.7 26.5 1067 500

    20x3x1 0.6 1.8 29.7 1309 500

    24x3x1 0.6 1.9 33.0 1545 500

    30x3x1 0.6 2.0 35.1 1878 500

    Conductor : 1.5 mm2 (7x0.53 mm)

    1x3x1.5 0.7 1.1 9.5 138 1000

    2x3x1.5 0.7 1.3 14.8 283 1000

    3x3x1.5 0.7 1.3 15.7 356 1000

    4x3x1.5 0.7 1.4 17.4 449 1000

    5x3x1.5 0.7 1.4 19.2 561 1000

    6x3x1.5 0.7 1.5 21.0 652 1000

    7x3x1.5 0.7 1.5 21.0 719 1000

    10x3x1.5 0.7 1.7 27.0 1019 500

    12x3x1.5 0.7 1.7 27.9 1177 500

    16x3x1.5 0.7 1.9 31.3 1510 500

    20x3x1.5 0.7 2.0 35.0 1862 500

    24x3x1.5 0.7 2.1 39.0 2195 500

    30x3x1.5 0.7 2.2 41.5 2646 500

    RE-YCYIEC 60092-376 150/250 V (300 V)

  • 47

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 2.5 mm2 (7x0.67 mm)

    1x3x2.5 0.7 1.1 10.4 178 1000

    2x3x2.5 0.7 1.3 16.4 363 1000

    3x3x2.5 0.7 1.4 17.6 477 1000

    4x3x2.5 0.7 1.4 19.5 621 1000

    5x3x2.5 0.7 1.5 21.5 756 1000

    6x3x2.5 0.7 1.6 23.6 883 1000

    7x3x2.5 0.7 1.6 23.6 980 1000

    10x3x2.5 0.7 1.8 30.4 1393 500

    12x3x2.5 0.7 1.9 31.6 1616 500

    16x3x2.5 0.7 2.0 35.2 2090 500

    20x3x2.5 0.7 2.1 39.4 2550 500

    24x3x2.5 0.7 2.3 44.1 3055 500

    30x3x2.5 0.7 2.4 46.9 3702 500

    RE-YCY

    Additional Options (by request)

    Reduced smoke PVC

    Tested acc to ASTM E662 &

    Improved Flame Retardant

    acc to IEC 60332-3

    UV Resistant PVC Sheath

    Acc to UL 1581-1200

    Oil & Chemical

    Resistant PVC Sheath

    Acc to ICEA S-82-552

    (Equal to NEMA WC55)

    Low smoke

    Acc to IEC 61034

    Low Halogen Acid & Gas

    acc to IEC 60754-1&2

    IEC 60502 ST8

    A) Based on PVC Sheath

    B) Based on Halogen Free Construction Cable Type : RE-2XCH

    IEC 60092-376 150/250 V (300 V)

  • KCI

    48

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Conductor Stranded (class 2) Plain annealed copper wires

    Insulation PVC

    Cable Unit Pair (Multi-Pair Cable)

    Individual Element

    Screen

    Polyester tape + Drain wire (Tinned copper) +

    Al.Polyester Tape + Polyester Tape

    Collective (Overall )

    ScreenBraid of Copper wires

    Outer Sheath Extruded PVC

    Criteria Standard Values Unit

    Conductor cross section Nominal 0.5 0.75 1 1.5 2.5 mm

    Conductor DC Resistance

    @ 20oCmax. 40.4 26 19.2 12.8 7.86 Ohm/kM

    Insulation resistance min. 100MOhm x

    km

    Mutual capacitance max. 250 nF/km

    L/R (ratio) max. 25 25 25 40 60microH/

    Ohm

    Test voltage :

    for 5

    minutes 1.5 kV A.C K.V core to core

    core to screen

    Operating voltage U(rms) 300 V

    Color Coding (Options) :

    Black,White (Numbered) Black,Blue (Numbered) IEC 60708 Full color

    RE-YCY , PiMF

    IEC 60092-376 150/250 V (300 V)

    7.5x O.D+70 oC IEC 60332-1 Screened

  • 49

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 0.5 mm2 (7x0.3 mm)

    1x2x0.5 0.6 1.0 7.4 84 1000

    2x2x0.5 0.6 1.2 11.3 157 1000

    3x2x0.5 0.6 1.2 12.2 214 1000

    4x2x0.5 0.6 1.2 13.3 262 1000

    5x2x0.5 0.6 1.3 14.6 310 1000

    6x2x0.5 0.6 1.3 15.8 361 1000

    7x2x0.5 0.6 1.3 15.8 395 1000

    10x2x0.5 0.6 1.5 20.5 587 1000

    12x2x0.5 0.6 1.5 21.1 661 1000

    16x2x0.5 0.6 1.6 23.5 841 1000

    20x2x0.5 0.6 1.7 26.3 1023 500

    24x2x0.5 0.6 1.8 29.2 1219 500

    30x2x0.5 0.6 1.9 31.1 1458 500

    Conductor : 0.75 mm2 (7x0.37 mm)

    1x2x0.75 0.6 1.0 7.8 96 1000

    2x2x0.75 0.6 1.2 12.3 194 1000

    3x2x0.75 0.6 1.2 13.0 246 1000

    4x2x0.75 0.6 1.3 14.4 301 1000

    5x2x0.75 0.6 1.3 15.6 357 1000

    6x2x0.75 0.6 1.4 17.1 423 1000

    7x2x0.75 0.6 1.4 17.1 463 1000

    10x2x0.75 0.6 1.5 22.0 678 1000

    12x2x0.75 0.6 1.6 22.9 776 1000

    16x2x0.75 0.6 1.7 25.5 982 500

    20x2x0.75 0.6 1.8 28.5 1203 500

    24x2x0.75 0.6 1.9 31.6 1417 500

    30x2x0.75 0.6 2.0 33.6 1700 500

    RE-YCY , PiMF

    IEC 60092-376 150/250 V (300 V)

  • KCI

    50

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 1.0 mm2 (7x0.43 mm)

    1x2x1 0.6 1.0 8.2 98 1000

    2x2x1 0.6 1.2 12.9 206 1000

    3x2x1 0.6 1.2 13.7 253 1000

    4x2x1 0.6 1.3 15.1 316 1000

    5x2x1 0.6 1.3 16.5 374 1000

    6x2x1 0.6 1.4 18.1 434 1000

    7x2x1 0.6 1.4 18.1 475 1000

    10x2x1 0.6 1.6 23.5 707 1000

    12x2x1 0.6 1.6 24.2 797 1000

    16x2x1 0.6 1.7 27.0 1009 500

    20x2x1 0.6 1.8 30.2 1237 500

    24x2x1 0.6 1.9 33.6 1458 500

    30x2x1 0.6 2.0 35.7 1768 500

    Conductor : 1.5 mm2 (7x0.53 mm)

    1x2x1.5 0.7 1.1 9.4 127 1000

    2x2x1.5 0.7 1.3 14.9 263 1000

    3x2x1.5 0.7 1.3 15.8 326 1000

    4x2x1.5 0.7 1.4 17.5 408 1000

    5x2x1.5 0.7 1.4 19.3 511 1000

    6x2x1.5 0.7 1.5 21.2 591 1000

    7x2x1.5 0.7 1.5 21.2 648 1000

    10x2x1.5 0.7 1.7 27.2 918 500

    12x2x1.5 0.7 1.7 28.1 1055 500

    16x2x1.5 0.7 1.9 31.6 1347 500

    20x2x1.5 0.7 2.0 35.3 1657 500

    24x2x1.5 0.7 2.1 39.3 1950 500

    30x2x1.5 0.7 2.2 41.8 2354 500

    RE-YCY , PiMF

    IEC 60092-376 150/250 V (300 V)

  • 51

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 2.5 mm2 (7x0.67 mm)

    1x2x2.5 0.7 1.1 10.2 159 1000

    2x2x2.5 0.7 1.3 16.4 328 1000

    3x2x2.5 0.7 1.4 17.6 424 1000

    4x2x2.5 0.7 1.4 19.5 551 1000

    5x2x2.5 0.7 1.5 21.5 669 1000

    6x2x2.5 0.7 1.6 23.6 778 1000

    7x2x2.5 0.7 1.6 23.6 858 1000

    10x2x2.5 0.7 1.8 30.4 1218 500

    12x2x2.5 0.7 1.9 31.6 1406 500

    16x2x2.5 0.7 2.0 35.3 1810 500

    20x2x2.5 0.7 2.1 39.5 2200 500

    24x2x2.5 0.7 2.3 44.2 2635 500

    30x2x2.5 0.7 2.4 47.0 3177 500

    Additional Options (by request)

    Reduced smoke PVC

    Tested acc to ASTM E662 &

    Improved Flame Retardant

    acc to IEC 60332-3

    UV Resistant PVC Sheath

    Acc to UL 1581-1200

    Oil & Chemical

    Resistant PVC Sheath

    Acc to ICEA S-82-552

    (Equal to NEMA WC55)

    Low smoke

    Acc to IEC 61034

    Low Halogen Acid & Gas

    acc to IEC 60754-1&2

    IEC 60502 ST8

    A) Based on PVC Sheath

    B) Based on Halogen Free Construction Cable Type : RE-2XCH

    RE-YCY , PiMF

    IEC 60092-376 150/250 V (300 V)

  • KCI

    52

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Conductor Stranded (class 2) Plain annealed copper wires

    Insulation PVC

    Cable Unit Triple (Multi-Triple Cable)

    Individual Element

    Screen

    Polyester tape + Drain wire (Tinned copper) +

    Al.Polyester Tape + Polyester Tape

    Collective (Overall )

    ScreenBraid of Copper Wires

    Outer Sheath Extruded PVC

    Criteria Standard Values Unit

    Conductor cross section Nominal 0.5 0.75 1 1.5 2.5 mm

    Conductor DC Resistance

    @ 20oCmax. 40.4 26 19.2 12.8 7.86 Ohm/kM

    Insulation resistance min. 100MOhm x

    km

    Mutual capacitance max. 250 nF/km

    L/R (ratio) max. 25 25 25 40 60microH/

    Ohm

    Test voltage :

    for 5

    minutes 1.5 kV A.C K.V core to core

    core to screen

    Operating voltage U(rms) 300 V

    RE-YCY , TiMF

    Color Coding (Options) :

    Black,White,Red (Numbered) Blue,White,Red (Numbered)

    IEC 60092-376 150/250 V (300 V)

    7.5x O.D+70 oC IEC 60332-1 Screened

  • 53

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 0.5 mm2 (7x0.3 mm)

    1x3x0.5 0.6 1.0 7.7 98 1000

    2x3x0.5 0.6 1.2 12.6 202 1000

    3x3x0.5 0.6 1.2 13.4 257 1000

    4x3x0.5 0.6 1.3 14.8 322 1000

    5x3x0.5 0.6 1.3 16.1 374 1000

    6x3x0.5 0.6 1.4 17.6 443 1000

    7x3x0.5 0.6 1.4 17.6 486 1000

    10x3x0.5 0.6 1.6 22.9 722 1000

    12x3x0.5 0.6 1.6 23.6 816 1000

    16x3x0.5 0.6 1.7 26.3 1034 500

    20x3x0.5 0.6 1.8 29.4 1268 500

    24x3x0.5 0.6 1.9 32.7 1496 500

    30x3x0.5 0.6 2.0 34.7 1824 500

    Conductor : 0.75 mm2 (7x0.37 mm)

    1x3x0.75 0.6 1.0 8.2 110 1000

    2x3x0.75 0.6 1.2 13.5 233 1000

    3x3x0.75 0.6 1.3 14.5 298 1000

    4x3x0.75 0.6 1.3 15.8 367 1000

    5x3x0.75 0.6 1.4 17.4 446 1000

    6x3x0.75 0.6 1.4 19.1 544 1000

    7x3x0.75 0.6 1.4 19.1 597 1000

    10x3x0.75 0.6 1.6 24.6 835 500

    12x3x0.75 0.6 1.7 25.6 968 500

    16x3x0.75 0.6 1.8 28.5 1237 500

    20x3x0.75 0.6 1.9 31.8 1503 500

    24x3x0.75 0.6 2.0 35.4 1797 500

    30x3x0.75 0.6 2.1 37.7 2157 500

    RE-YCY , TiMFIEC 60092-376 150/250 V (300 V)

  • KCI

    54

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 1.0 mm2 (7x0.43 mm)

    1x3x1 0.6 1.1 8.8 124 1000

    2x3x1 0.6 1.3 14.4 252 1000

    3x3x1 0.6 1.3 15.3 322 1000

    4x3x1 0.6 1.3 16.7 396 1000

    5x3x1 0.6 1.4 18.4 472 1000

    6x3x1 0.6 1.5 20.4 585 1000

    7x3x1 0.6 1.5 20.4 641 1000

    10x3x1 0.6 1.7 26.2 907 500

    12x3x1 0.6 1.7 27.1 1030 500

    16x3x1 0.6 1.8 30.2 1318 500

    20x3x1 0.6 1.9 33.8 1631 500

    24x3x1 0.6 2.1 37.8 1931 500

    30x3x1 0.6 2.1 40.0 2299 500

    Conductor : 1.5 mm2 (7x0.53 mm)

    1x3x1.5 0.7 1.1 9.8 156 1000

    2x3x1.5 0.7 1.3 16.4 327 1000

    3x3x1.5 0.7 1.4 17.7 421 1000

    4x3x1.5 0.7 1.4 19.6 547 1000

    5x3x1.5 0.7 1.5 21.6 664 1000

    6x3x1.5 0.7 1.6 23.7 773 1000

    7x3x1.5 0.7 1.6 23.7 852 1000

    10x3x1.5 0.7 1.8 30.5 1209 500

    12x3x1.5 0.7 1.9 31.7 1395 500

    16x3x1.5 0.7 2.0 35.4 1795 500

    20x3x1.5 0.7 2.1 39.6 2181 500

    24x3x1.5 0.7 2.3 44.3 2613 500

    30x3x1.5 0.7 2.4 47.1 3149 500

    RE-YCY , TiMF

    IEC 60092-376 150/250 V (300 V)

  • 55

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    Nominal cross section area of

    conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm Kg/Km meter

    Conductor : 2.5 mm2 (7x0.67 mm)

    1x3x2.5 0.7 1.1 10.7 195 1000

    2x3x2.5 0.7 1.4 18.4 416 1000

    3x3x2.5 0.7 1.4 19.7 572 1000

    4x3x2.5 0.7 1.5 21.8 724 1000

    5x3x2.5 0.7 1.6 24.1 867 1000

    6x3x2.5 0.7 1.7 26.4 1023 500

    7x3x2.5 0.7 1.7 26.4 1136 500

    10x3x2.5 0.7 2.0 34.3 1652 500

    12x3x2.5 0.7 2.0 35.4 1887 500

    16x3x2.5 0.7 2.1 39.6 2408 500

    20x3x2.5 0.7 2.3 44.5 2980 500

    24x3x2.5 0.7 2.5 49.8 3577 500

    30x3x2.5 0.7 2.6 53.0 4331 250

    Additional Options (by request)

    Reduced smoke PVC

    Tested acc to ASTM E662 &

    Improved Flame Retardant

    acc to IEC 60332-3

    UV Resistant PVC Sheath

    Acc to UL 1581-1200

    Oil & Chemical

    Resistant PVC Sheath

    Acc to ICEA S-82-552

    (Equal to NEMA WC55)

    Low smoke

    Acc to IEC 61034

    Low Halogen Acid & Gas

    acc to IEC 60754-1&2

    IEC 60502 ST8

    A) Based on PVC Sheath

    B) Based on Halogen Free Construction Cable Type : RE-2XCH

    RE-YCY , TiMF

    IEC 60092-376 150/250 V (300 V)

  • Kerman & Kavian Cable Industries ( KCI )

  • KCI

    RE-2X(St)YQY Multi-Pair

    RE-2X(St)YQY Multi-Triple

    RE-2X(St)YQY PiMF

    RE-2X(St)YQY TiMF

    RE-2X(St)YQY

    RE-2X(St)HQH

    RE-2X(St)YQY Multi-Core

    RE-2X(St)HQH Multi-Core

    RE-2X(St)HQH Multi-Pair

    RE-2X(St)HQH Multi-Triple

    RE-2X(St)HQH PiMF

    RE-2X(St)HQH TiMF

    IEC 60092-376 150/250 V (300 V)

    Alternatively ; Low Smoke , Halogen free Type :

  • KCI

    58

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    Conductor Stranded (class 2) Plain annealed copper wires

    Insulation XLPE

    Cable Unit Core (Multi-Core Cable)

    Collective (Overall )

    Screen

    Polyester tape + Drain wire (Tinned copper) +

    Al.Polyester Tape

    Inner Covering

    (Bedding) Extruded PVC

    Armour Braid of Galvanized Steel Wires

    Outer Sheath Extruded PVC

    RE-2X(St)QY

    Criteria Standard Values Unit

    Conductor cross section Nominal 0.5 0.75 1 1.5 2.5 mm

    Conductor DC Resistance

    @ 20oCmax. 40.4 26 19.2 12.8 7.86 Ohm/kM

    Insulation resistance min. 1000MOhm x

    km

    Mutual capacitance max. 150 nF/km

    L/R (ratio) max. 25 25 25 40 60microH/

    Ohm

    Test voltage :

    for 5

    minutes 1.5 kV A.C K.V core to core

    core to screen

    Operating voltage U(rms) 300 V

    Color Coding (Options) :

    Black (Numbered) Yellow or White (Numbered)

    IEC 60092-376 150/250 V (300 V)

    10x O.D+90 oC IEC 60332-1 Screened Armoured

  • 59

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    www.kermancableind.com Email : [email protected] Tel : +98 21 22669500 -10-20 (30 lines) Fax: +98 21 22028427

    RE-2X(St)QY

    Nominal cross section

    area of conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Arm

    ou

    r W

    ire

    Dia

    met

    er

    Dia

    met

    er U

    nd

    er

    Arm

    ou

    r

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm mm mm Kg/Km meter

    Conductor : 0.5 mm2 (7x0.30 mm)

    2x0.5 0.4 0.2 5.7 1.1 8.8 117 1000

    3x0.5 0.4 0.2 6.0 1.1 9.1 126 1000

    4x0.5 0.4 0.2 6.4 1.1 9.5 137 1000

    5x0.5 0.4 0.2 6.9 1.1 10.0 148 1000

    6x0.5 0.4 0.2 7.4 1.1 10.5 166 1000

    7x0.5 0.4 0.2 7.4 1.1 10.5 172 1000

    8x0.5 0.4 0.2 8.4 1.2 11.7 201 1000

    10x0.5 0.4 0.2 9.1 1.2 12.4 221 1000

    12x0.5 0.4 0.2 9.4 1.2 12.7 236 1000

    16x0.5 0.4 0.2 10.3 1.3 13.8 284 1000

    20x0.5 0.4 0.3 11.3 1.3 15.3 359 1000

    24x0.5 0.4 0.3 12.5 1.4 16.6 405 1000

    30x0.5 0.4 0.3 13.2 1.4 17.3 451 1000

    Conductor : 0.75 mm2 (7x0.37 mm)

    2x0.75 0.5 0.2 6.5 1.1 9.6 132 1000

    3x0.75 0.5 0.2 6.8 1.1 9.9 145 1000

    4x0.75 0.5 0.2 7.4 1.1 10.5 167 1000

    5x0.75 0.5 0.2 8.0 1.2 11.3 188 1000

    6x0.75 0.5 0.2 8.6 1.2 11.9 210 1000

    7x0.75 0.5 0.2 8.6 1.2 11.9 220 1000

    8x0.75 0.5 0.2 9.9 1.2 13.2 243 1000

    10x0.75 0.5 0.3 10.7 1.3 14.7 308 1000

    12x0.75 0.5 0.3 11.1 1.3 15.0 345 1000

    16x0.75 0.5 0.3 12.2 1.4 16.4 404 1000

    20x0.75 0.5 0.3 13.5 1.4 17.7 459 1000

    24x0.75 0.5 0.3 14.9 1.5 19.3 534 1000

    30x0.75 0.5 0.3 15.8 1.5 20.2 621 1000

    IEC 60092-376 150/250 V (300 V)

  • KCI

    60

    Inst

    rum

    ent

    Cab

    les

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K

    CI

    )

    Kerman & Kavian Cable Industries Head office : No.18 , Hasti alley , valiasr St, Chamran cross-road , 19656-13311 Tehran , IRAN

    RE-2X(St)YQY

    Nominal cross section

    area of conductor

    Insu

    lati

    on

    thic

    kn

    ess

    Arm

    ou

    r W

    ire

    Dia

    met

    er

    Dia

    met

    er U

    nd

    er

    Arm

    ou

    r

    Sh

    eath

    th

    ick

    nes

    s

    Over

    all

    Dia

    met

    er

    Wei

    gh

    t

    Sta

    nd

    ard

    Pack

    ing L

    ength

    mm2 mm mm mm mm mm Kg/Km meter

    Conductor : 1.0 mm2 (7x0.43 mm)

    2x1 0.5 0.2 6.9 1.1 10.0 136 1000

    3x1 0.5 0.2 7.2 1.1 10.3 158 1000

    4x1 0.5 0.2 7.8 1.2 11.1 182 1000

    5x1 0.5 0.2 8.5 1.2 11.8 207 1000

    6x1 0.5 0.2 9.2 1.2 12.5 227 1000

    7x1 0.5 0.2 9.2 1.2 12.5 239 1000

    8x1 0.5 0.3 10.5 1.3 14.5 303 1000

    10x1 0.5 0.3 11.4 1.3 15.4 353 1000

    12x1 0.5 0.3 11.8 1.3 15.8 381 1000

    16x1 0.5 0.3 13.1 1.4 17.2 453 1000

    20x1 0.5 0.3 14.5 1.4 18.6 536 1000

    24x1 0.5 0.3 16.0 1.5 20.4 627 1000

    30x1 0.5 0.3 17.0 1.5 21.3 712 1000

    Conductor : 1.5 mm2 (7x0.53 mm)

    2x1.5 0.6 0.2 7.9 1.2 11.2 170 1000

    3x1.5 0.6 0.2 8.3 1.2 11.6 193 1000

    4x1.5 0.6 0.2 9.0 1.2 12.3 226 1000

    5x1.5 0.6 0.2 9.8 1.2 13.1 253 1000

    6x1.5 0.6 0.3 10.7 1.3 14.6 317 1000

    7x1.5 0.6 0.3 10.7 1.3 14.6 335 1000

    8x1.5 0.6 0.3 12.3 1.3 16.3 389 1000

    10x1.5 0.6 0.3 13.4 1.4 17.6 447 1000

    12x1.5 0.6 0.3 13.9 1.4 18.0 505 1000

    16x1.5 0.6 0.3 15.4 1.5 19.8 621 1000

    20x1.5 0.6 0.3 17.2 1.5 21.5 716 1000

    24x1.5 0.6 0.3 19.0 1.6 23.6 844 1000

    30x1.5 0.6 0.3 20.2 1.7 24.9 980 500

    IEC 60092-376 150/250 V (300 V)

  • 61

    Inst

    rum

    ent

    Cab

    les

    KCI

    Ker

    man

    & K

    avia

    n C

    able

    Indust

    ries

    ( K