JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

DOC No. 7ZPNA4013D

RECORD OF REVISIONS

Rev Description Date

1.0 First edition 17-Oct.-06

1.1 Revised 13.Report 19-Jan-07

2.0 Setup for Remote Maintenance is added. 17-Feb-07

A ・Setup for NAV-I/F unit is added. ・Document Code is revised 7ZPNA4013A 9-Apr-07

B

・Registration method of VHF installation place was added. ・Operation method of conversion software was added. ・Language setup was added. ・Document Code is revised 7ZPNA4013B.

20-May-08

C ・Conforms to Windows Vista

・Document Code is revised 7ZPNA4013C. 28-Oct-08

D

・Note about the speed improvement of configuration data reception process by [Receive] button was added.

・The method for additionally installing RMB was added. ・RMS Setup method was changed. ・RMS Viewer operation instruction was added. ・Multicast setup method for VDR real-time output was added. ・Download method for the latest data from CF card was added. ・The operation method for opening configuration file was modified. ・The method for updating Capsule software was added. ・Document Code is revised to 7ZPNA4013D.

8-May-09

Page 4: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

DOC No. 7ZPNA4013AD

Page 5: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

i DOC No. 7ZPNA4013D

TABLE OF CONTENTS 1. Maintenance Software ................................................................................................................... 1 2. Starting and Quitting the Maintenance Software ........................................................................ 3

2.1. Starting the Maintenance software ............................................................................................................................3 2.2. Quitting the Maintenance software............................................................................................................................5

3. Selecting Work Item....................................................................................................................... 7 3.1. Home screen.................................................................................................................................................................7 3.2. Work menu ..................................................................................................................................................................7

4. Installation, Setup, and Operation Check.................................................................................... 9 4.1. Selecting the installation .............................................................................................................................................9 4.2. Receiving a configuration data and starting the diagnosis function......................................................................12 4.3. Sensor connection setup ............................................................................................................................................13 4.4. NSK connection setup ...............................................................................................................................................26 4.5. Option unit (NCT-72/63) connection setup..............................................................................................................31 4.6. Option unit (NCT-52A) connection setup ................................................................................................................52 4.7. Radar connection setup.............................................................................................................................................61 4.8. Microphone connection setup...................................................................................................................................68 4.9. VHF connection setup ...............................................................................................................................................73 4.10. VDR/S-VDR system setup ........................................................................................................................................76 4.11. Capsule setup .............................................................................................................................................................87 4.12. System Configuration File ........................................................................................................................................89

5. SYSTEM Screen ........................................................................................................................... 91 5.1. Buttons commonly used on the SYSTEM screen ....................................................................................................92 5.2. Sensor section.............................................................................................................................................................93 5.3. Indicating the modified setup ...................................................................................................................................94 5.4. Diagnosis function .....................................................................................................................................................95 5.5. System status window ...............................................................................................................................................96 5.6. Operation button .......................................................................................................................................................98 5.7. File menu....................................................................................................................................................................98

6. EVENT Monitor ............................................................................................................................. 99 6.1. Starting .......................................................................................................................................................................99 6.2. Modification of EVENT list display .......................................................................................................................101 6.3. Opening the EVENT log file ...................................................................................................................................104 6.4. Saving the EVENT log file ......................................................................................................................................104 6.5. EVENT monitor record ..........................................................................................................................................105

7. Real Time Monitor (Menu) ......................................................................................................... 107 7.1. Starting .....................................................................................................................................................................107 7.2. NMEA monitor ........................................................................................................................................................108 7.3. Audio monitor.......................................................................................................................................................... 111 7.4. Radar monitor ......................................................................................................................................................... 112 7.5. Dry Contact monitor ............................................................................................................................................... 113

8. System Status Display................................................................................................................117 8.1. Starting ..................................................................................................................................................................... 117 8.2. System status display Window ............................................................................................................................... 117 8.3. Starting System status display ................................................................................................................................ 119 8.4. Diagnosis lamp of orange in normal operation ..................................................................................................... 119 8.5. System status data file .............................................................................................................................................120

Page 6: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

ii DOC No. 7ZPNA4013D

9. Functions of Menu ..................................................................................................................... 121

9.1. Menu table ...............................................................................................................................................................121 9.2. Control .....................................................................................................................................................................122 9.3. Converting the Recorded data to general files (.txt .png .wav)............................................................................125 9.4. Config (Extract a setup file from a SysInfo.dat file) .............................................................................................129 9.5. Downloading from CF Card(Card Download) ................................................................................................130 9.6. Error Code List .......................................................................................................................................................131 9.7. Software Version display.........................................................................................................................................132

10. Playback...................................................................................................................................... 133 10.1. Starting .....................................................................................................................................................................133 10.2. Playback Software ...................................................................................................................................................134 10.3. Check the recorded data .........................................................................................................................................134

11. Frame Grabber Board (CKA-137) Setup - FGB Utility - .......................................................... 135 11.1. Check the Radar image specifications ...................................................................................................................135 11.2. Setup & Capture......................................................................................................................................................135 11.3. Tuning.......................................................................................................................................................................140

12. “OPTION” System Setup ........................................................................................................... 145 12.1. Starting .....................................................................................................................................................................145 12.2. Setup Procedure ......................................................................................................................................................146 12.3. Registration Information ........................................................................................................................................146 12.4. IP Address ................................................................................................................................................................146 12.5. “Real Time Monitor” Section .................................................................................................................................147

13. Report.......................................................................................................................................... 149 13.1. Starting .....................................................................................................................................................................149

14. Program Update ......................................................................................................................... 155 14.1. Program update of MCB, ARB and RMB.............................................................................................................155 14.2. Program update of FGB .........................................................................................................................................157 14.3. Program update of Capsule ....................................................................................................................................159

15. Playback Software Setup .......................................................................................................... 161 15.1. How to play back the downloaded data from the Capsule via Ethernet .............................................................161 15.2. How to play back the CF card data........................................................................................................................167 15.3. How to quit the Playback software ........................................................................................................................171

16. Remote Maintenance System Setup ........................................................................................ 173 16.1. Log in........................................................................................................................................................................173 16.2. HOME screen ..........................................................................................................................................................174 16.3. System screen...........................................................................................................................................................174

17. Installation .................................................................................................................................. 187 17.1. Uninstall the old version .........................................................................................................................................187 17.2. Installation procedure .............................................................................................................................................187 17.3. Language setting of maintenance PC.....................................................................................................................195

Page 7: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

1. Maintenance SoftwareJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

1 DOC No. 7ZPNA4013D

1. Maintenance Software

The maintenance software of JCY-1800/1850 is a PC-based application. The original task of the software is to check the equipment and to create the As-delivered software configuration. On board a ship, this is a versatile tool for a service engineer, too. The software helps him to install the equipment, reconfigure the setting, carry out the operation check and locate the fault, if any.

1) Software name:

JCY1800-maint.exe

2) Language used:

English

3) Characters used for entry:

English one-byte characters only The number of characters that can be inputted is limited by each entry field. Entry over the maximum allowable number is denied.

4) Installation of the maintenance software:

Use “setup.exe” for installing this software to the maintenance PC. Refer to Chapter 16 for the installation of this software.

For Windows Vista It is necessary to release UAC (user account control) for Windows Vista. Please install it according to the procedure of "Installation" in Chapter 17. When UAC has not been canceled, it is not possible to operate normally.

5) OS:

・ Windows XP ・ Windows Vista (SP1 or after it)

Language setting If the Maintenance PC is not Japanese OS or English OS, please set language to the “English (United States” or the “English (United Kingdom)” in the Control Panel screen of Windows. Depending on language, the Maintenance software may not operate normally. Refer to "17.3 Language setting for Maintenance PC" about the setting method of language.

6) PC:

A laptop that meets the following or higher requirements: •OS •CPU

:Windows XP / Vista (SP1 or after it) :1GHz or more

• Memory :512Mbytes or more(XP) : 1Gbytes or more(Vista)

•PCMCIA card slot :CF card as a data backup medium of VDR/S-VDR (A delivered card adapter is attached to the RCU.)

•Communication I/F :Ethernet (10/100Mbps) •Screen resolution :1024×768 (XGA) or more •Display font :Small size font only

Page 8: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

1. Maintenance Software JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

2 DOC No. 7ZPNA4013D

7) Personal Firewall

In case a personal firewall is run on the PC, suspend the function before using the maintenance software.

Personal Firewall A personal firewall is a filtering facility of LAN communication link attached to OS (Windows XP, Vista) and the software to detect and isolate a virus.

When a personal firewall is enabled; The VDR/S-VDR cannot communicate with the maintenance PC.

8) Other requirements for maintenance:

LAN cable (Built in the RCU.) →Makes LAN connection from the Maintenance PC to the HUB unit of the RCU.

9)

Connection port for the Maintenance PC

Connect the Maintenance PC to any of the “VDR-LAN” ports.

-------------- ABBREVIATIONS --------------- Some of the abbreviations commonly used in this manual are:

Abbreviations Name of the Unit Code HVR/SVR Capsule NDH-316/317 RCU Recording Control Unit NDV-1800/1850 MCB Main Control Board CDJ-2304 FGB Frame Grabber Board CKA-137 ARB Audio Recording Board CHA-387 RMB Remote Maintenance Board CDJ-2143 OPU Operation Panel Unit NCG-169 DSC Digital Signal Converter (64CH/16CH) NCT-72/63 ACB Analog Signal Convert Board (DSC option) CEF-60

Page 9: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

2. Starting and Quitting the Maintenance SoftwareJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

3 DOC No. 7ZPNA4013D

2. Starting and Quitting the Maintenance Software

2.1. Starting the Maintenance software

2.1.1. Starting procedure 1) To load the maintenance software, double click the “Maintenance Software” icon on the desktop assuming that

the Maintenance software has already been successfully installed. (cf. Chapter 16) 2) The maintenance Software starts and then Login screen will appear.

2.1.2. Log in screen

Page 10: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

2. Starting and Quitting the Maintenance Software JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

4 DOC No. 7ZPNA4013D

2.1.2.1. Selecting setup system (“Setup Equipment”)

Select a setup system from VDR, S-VDR or RMS.

2.1.2.2. Entering User name, Company name and Password (“Register Information”) 1) Register Information

Enter the following user information, which will be recorded onto the VDR/S-VDR. • User name • Company name

2) Password The entered letters are indicated with asterisks (“******”). This is the password for field engineer. All "jrcvdr" is small letters.

2.1.2.3. Selecting Ethernet adapter The Maintenance software will detect an Ethernet adapter in the PC automatically. When the PC has more than one Ethernet adapters, select “wired LAN” as an adapter interface to the VDR/S-VDR using ▼ button.

Many models of recent laptop have not only wired LAN but also wireless LAN. Select “wired LAN” as the interface.

2.1.2.4. Adding IP address for VDR/S-VDR Check the IP address and the Subnet mask which are registered to Ethernet adapter. The IP address for VDR/S-VDR maintenance is added. (192.168.110.200)

The IP address added for VDR/S-VDR maintenance is deleted when the PC is rebooted.

2.1.2.5. Login Click the [Next] button. After successful login to the VDR/S-VDR, “HOME screen” will appear.

Page 11: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

2. Starting and Quitting the Maintenance SoftwareJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

5 DOC No. 7ZPNA4013D

2.2. Quitting the Maintenance software

2.2.1. Check before quitting

Confirm the following items before logout when the installation is finished 1. All Entry lamps are lit green in the System screen. 2. All Diagnosis lamps are lit green in the System screen. 3. Any error event is not arisen on real time Event monitor. 4. The downloaded data from the capsule can be played back rightly. 5. The copied data from the CF card can be played back rightly. 6. Report files are saved with Report function.

2.2.2. Quitting procedure Click the [Log out] button on the left side of each screen. The maintenance software is shut down after logging out from the VDR/S-VDR.

Page 12: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

2. Starting and Quitting the Maintenance Software JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

6 DOC No. 7ZPNA4013D

This page left blank intentionally

Page 13: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

3. Selecting Work ItemJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

7 DOC No. 7ZPNA4013D

3. Selecting Work Item

3.1. Home screen Operation button Work buttons

3.1.1. Selecting the work item Click a work button on the Work section. The screen for the selected working item will appear.

3.2. Work menu

3.2.1. Installation Select “Installation” for installing, setting and checking the VDR/S-VDR system. Following items are available on

“Installation”. • As-delivered factory setting • Field setup • Operation check of the VDR/S-VDR • Annual inspection • In field fault locating and remedy

Page 14: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

3. Selecting Work Item JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

8 DOC No. 7ZPNA4013D

3.2.2. Playback Select Playback for checking the recorded data on the VDR/S-VDR. The Playback software will be activated.

3.2.3. Option PC (VDR Real Time Monitor) Select Option PC for setting up a real time monitor system. * Option PC merely enables/disables the output of a real-time monitor data.

Refer to the "VDR/S-VDR Real Time Monitor Installation Manual" for details.

3.2.4. RCU Update Select RCU Update for updating the program of each unit.

• MCB (Boot program/Application program) • ARB (Application program) • RMB (Boot program/Application program)

* Update of FGB program can be performed from the menu of SYSTEM screen.

3.2.5. Capsule Update Select Capsule Update for updating the following capsule software. Click the corresponding button after checking the capsule’s model connected to VDR/S-VDR. Capsule’s Model Button Note NDH-316 [NDH-316 Update] NHD-316A [NHD-316A Update]

When logging in by VDR, selection is available.

NDH-317 [NDH-317 Update] NDH-317A [NDH-317A Update]

When logging in by S-VDR, selection is available.

Page 15: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

9 DOC No. 7ZPNA4013D

4. Installation, Setup, and Operation Check

4.1. Selecting the installation

4.1.1. Home screen [Installation] To configure the VDR/S-VDR, click the [Installation] button. The “SYSTEM” screen for the selected system (VDR/S-VDR/RMS) at log-in will appear. ● JCY-1800

Page 16: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

10 DOC No. 7ZPNA4013D

● JCY-1850

● JCY-1850 is different from JCY-1800 in; • The number of connectable sensor channels • The capsule model

Page 17: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

11 DOC No. 7ZPNA4013D

4.1.2. Operating procedure for installation Set up and check the VDR/S-VDR on the “SYSTEM” screen according to the following procedure.

“Report” folder is created on the Desktop of the PC automatically. Compress the folder, and upload the compressed files to the “Ship list” on the Marine service WEB.

Step Item Function triggered by; Contents See

1 Receiving the system configuration data Receive button

The Maintenance software receives the system configuration data from the RCU. Click the [Receive] button. Setup information is displayed on the System screen after receiving.

4.2.1

2 Setting each connection Check box for connection Check the box of each connection channel and each configuration unit referring to the Installation drawing.

4.3.1 4.4.1 4.5.1 4.6.1 4.7.1 4.8.1

3 Setting a detail information Each Detail button

Click the Detail button of the section to set up. Select the connection channel in sensor section before clicking the Detail button.

4 Transmitting a system configuration data to the RCU

Set button in each detail window

Click the Set button in the detail window after entering all data.

5 Setting up the System Repeat Step3 and Step4 Enter the detail information data of all section and each channel of the Sensor section.

4.3.2 4.4.2 4.5.2 4.6.2 4.7.2 4.8.2

6 Rebooting the RCU Reboot button Click the Reboot button on the System screen. The RCU is operated by renewed system configuration data, after rebooting.

Checking the diagnostic results

Diagnosis button and lamp

Click the Diagnosis button on the System screen. Maintenance software shows the diagnostic results by the color of each lamp. Green lamp means OK.

5

7

Receiving data Real time monitor Check the receiving data by the real time monitor. 7

8 Correct, if there is a problem. Return to STEP3

If the diagnostic lamp is lit red or yellow, a problem arose out of setup, installation or wiring. Rectify the fault accordingly. The orange color of lamp means the equipment is under diagnosis.

9 Recorded data Playback Check the recorded data by the Playback software. 10

10 Complete the setup All diagnostic lamps of System screen Make all lamps burn green and complete the setup. 5

11 Make the report Report Report files are created. 13

Page 18: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

12 DOC No. 7ZPNA4013D

4.2. Receiving a configuration data and starting the diagnosis function

4.2.1. Receiving a configuration data of RCU Receive the configuration parameters from RCU and start the maintenance operation. 1) Click the [Receive] button. 2) Confirm the reception has been completed with the progress bar.

The configuration data reception process by [Receive] button is improved to high-speed for MCB and RMB software Ver2.0.1 or later. As a result, the data can be received instantly.

Note that the earlier software version is not compatible for high-speed reception, so that it takes time as before.

4.2.2. Starting the diagnosis function The state of VDR/S-VDR system and OK/NG of receiving data are indicated by the color of “Diagnosis” lamps. The meaning of each color is:

● (Green): OK ● (Red): NG ● (Orange): The system is under diagnosis 1) Click the [Diagnosis] button. 2) Confirm that the color of [Diagnosis] button changed to green. * If the [Diagnosis] button is clicked during the diagnosis function is on, the function will be stopped.

Page 19: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

13 DOC No. 7ZPNA4013D

4.3. Sensor connection setup

4.3.1. Setting connection

Click the check box to have the sensor connected. 1) Each channel

Check the check box of connected CH as follows. Enable: [ ] (checked) Disable: [ ] (unchecked)

Opening detail window Check box

Selecting the subject CH of set up

Caution) Cross out the check mark in the check box when the sensor connection setup is to be undone (from enable to disable) temporarily. In this case, do not forget to delete the setup data referring to 4.3.3.3. If the setup data remains when the mark is removed from the check box, the data from the same sensor may not be recorded via other channel.

4.3.2. Starting detail setup The detailed setup window of each channel is displayed.

1) Selecting CH Click a radio button of setting sensor channel. 2) Click the [Detail] button on Sensor section, a detail setup window appears.

Page 20: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

14 DOC No. 7ZPNA4013D

4.3.3. Selecting a recording data

Select the connection equipment and recording data according to the following procedure. The default value for receiving the data of the equipment chosen is set up automatically on the detail setting window.

4.3.3.1. In the case of new setting

Select a “recording item” from the pull-down menu. Click the [Next] button.

Select the “equipment” to be connected from the pull-down menu.

Select “Other”, when there is no appropriate item that should be set up. Enter an appropriate data for connected equipment on "Data" tab screen. Caution) In case the recording data item to set up is not displayed:

Subject recording data is already registered in other channel(s). Clear the setup of CH registered. Setting data are not cleared simply by changing the setting from “enable” to “disable”. Refer to the following procedure for deleting setup data.

Page 21: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

15 DOC No. 7ZPNA4013D

4.3.3.2. Changing the registered setup data

• To change the detail setup data registered; Choose “No” (Default) of radio button and click the [Next] button.

• To change the selected “Recording item” and selected “Equipment”; Click “Yes” of radio button and click the [Next] button.

• To clear the “setup data”; Click “Do you want to delete information?” and click the [Next] button.

4.3.3.3. Deleting the registered setup data

Click “Do you want to delete information?” and click the [Next] button. The registered setup data is deleted. In the following cases, delete the setting data of CH which are not connected.

Example) As delivered, CH4 has been assigned as the input port of Gyro angle data in NMEA format. However on

the ship actual Gyro angle is distributed by step signal repeater. Therefore the setup on CH4 has to be cancelled. Instead, CH33 shall be assigned as the port of Gyro angle data.

1) Setup error If a setup data remains despite the check on CH4 has been crossed out, the following error dialog will be

displayed immediately after CH33 is checked.

2) Setup procedure Delete the setup data of the CH4 according to the aforementioned. Check the check box of CH33. Enter setup data for receiving the heading data into detail window of CH33.

Page 22: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

16 DOC No. 7ZPNA4013D

Selection table

Recording item Equipment ID Recording data Sentence ID

Date and Time ??ZDA ??RMC

??GGA ??GLL Ship's Position ??GNS ??RMCV

GPS(Main) 41

Local Geodetic Datum(DTM) ??DTM Date and Time ??ZDA ??RMC

??GGA Ship's Position ??GNS ??RMCV

GPS(Main+Sub) 71

Local Geodetic Datum(DTM) ??DTM Other ??ZDA ??RMC

??GGA Other ??GNS ??RMCV

Date & Time/Ship's

Position

GPS(Sub) 72

Other ??DTM Ship's Speed Speed Log 43 Ground/Water Speed ??VBW

Gyro Compass Ship's Heading ??HDT Ship's Heading

Magnetic Compass

44

Ship's Heading ??HDG

Echo Sounder(Bow) 47 Depth ??DPT

Other ??DPT

Depth

Echo Sounder(Stern) 59

Wind Speed and Direction Anemometer 48 Wind Speed and Direction ??MWV

Rudder Order, Manual ??HTD Autopilot 45

Rudder Response, Manual ??RSA Rudder Angle Indicator 46 Rudder Response, Manual ??RSA

Rudder Order/Response

ECDIS 51 Rudder Order, Automatic ??HTC M/E RPM Set Order(CPP order) ??PRC M/E Remote Control

System 50

M/E RPM Actual Response(CPP order) ??RPM

Engine Order/Response

Engine Telegraph 49 Telegraph Order Position ??ETL

Thruster 52 Thruster Response ??TRD Bow1 Thruster 53 Thruster Response ??TRD

Bow2 Thruster 54 Thruster Response ??TRD Stern1 Thruster 55 Thruster Response ??TRD

Thruster Order/Response

Stern2 Thruster 56 Thruster Response ??TRD Acceleration and Hull Stress

Hull Stress Monitor 57 Hull Stress ??HSS

Fire Door Status * Fire Door Status ??DOR

Watertight Door Panel * Watertight Door Status ??DOR Hull Door Controler * Hull Door Status ??DOR

Door Status

Ramp Way Indicator * Alarm Monitoring system *

Water Ingress Alarm System

*

Bilge Alarm Panel * Fire Detection System *

Main Alarms

Steering Gear * AIS VDO Data ??VDO

AIS VDM Data ??VDM Status Information ??TXT

AIS Data AIS 42

Main Alarm(ALR) ??ALR Radar Selection Radar(Main) 58 Radar Selection ??PJRC Other * Other

Page 23: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

17 DOC No. 7ZPNA4013D

Recording item Equipment ID Recording data Sentence ID

DSC (CH13) 60 Dry Contact Data (CH13) ????? DSC (CH14) 61 Dry Contact Data (CH14) ????? DSC (CH15) 62 Dry Contact Data (CH15) ????? DSC (CH16) 63 Dry Contact Data (CH16) ?????

Dry Contact Data (CH13) ????? DSC+A/D (CH13) 64

A/D Convert Data (CH13) VRXDR Dry Contact Data (CH14) ????? DSC+A/D (CH14) 65 A/D Convert Data (CH14) VRXDR Dry Contact Data (CH15) ????? DSC+A/D (CH15) 66 A/D Convert Data (CH15) VRXDR Dry Contact Data (CH16) ????? DSC+A/D (CH16) 67 A/D Convert Data (CH16) VRXDR

NAV-IF (NCT-52A) 68 NAV-I/F Data(Option Unit) ANADAT

Option Unit

NAV-IF (NCT-**) 69 NAV-I/F Data(Option Unit) ANADAT

Page 24: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

18 DOC No. 7ZPNA4013D

4.3.4. Detail setup window of sensor (standard)

4.3.4.1. Identification TAB screen

Set an identification data of connected equipment 1) Equipment

Enter the name of the connected equipment. (GPS, Echo sounder, etc.) * Unless “Other” is selected, a default equipment name is entered automatically.

2) Model Enter the model name of the connected equipment.

3) Manufacturer Enter the name of the manufacturer of the connected equipment.

4) Serial No. Enter the serial number of the connected equipment.

* If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.

Page 25: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

19 DOC No. 7ZPNA4013D

4.3.4.2. Data TAB screen

Change entry data, when required. Enter a setup data when “Other” is selected as record item in pre-procedure.

4.3.4.2.1. Type

Select the type of receiving sentences.

No. Type Connector Selectable CH Remark

1 NMEA General sensors CH01-CH32 NMEA 2 AIS AIS unit CH01-CH16 NMEA 3 DRY-CNT Digital signal converter unit (option) CH13-CH16 NCT-72/NCT-63 4 DCNT+A/D Equipment with built-in DSC

(Addition of the optional A/D converter board) CH13-CH16 NCT-72/NCT-63

(A/D built-in) 5 NSK NSK unit (option) CH01-CH32 NCT-27B 6 NAV-I/F NAV-I/F unit (option) CH13-CH16 NCT-52A

Page 26: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

20 DOC No. 7ZPNA4013D

4.3.4.2.2. Communication parameters and Sentence format

Set the communication parameter and the sentence format. Once the type is selected, following parameters are automatically set as default. There is no need to change these values.

TYPE NMEA AIS DRY-CNT DCNT+A/D NAV-IF NSK Baud Rate 4800 38400 4800 4800 19200 4800 Data Bits 8 8 8 8 8 8 Stop Bits 1 1 1 1 1 1 Parity None None None None None None Checksum enable enable enable enable enable enable Header $ ! $ $ $ $ Delimiter 0D0A 0D0A 0D0A 0D0A 0D0A 0D0A Max Length 82 82 82 82 82 82 Max Interval 15 200 315 15 15 15

1) Header Enter the header character.

Enter “$” for general sensor units. In case of connecting to the AIS, enter “!” as a header character. When “!” is entered, the RCU receives the NMEA sentences that have “$” and “!” as header. 2) Delimiter

Enter delimiter (the sign that means the end of the sentence). “OD OA” is recognized by the software as “<CR><LF>“.

3) Maximum length of sentence

Set the maximum length of the data sentence. Any data sentence of which length exceeds this maximum sentence length is denied and an error is arisen. The maximum length of the NMEA sentence is 82Bytes.

4) Maximum time interval of receiving

Set the maximum time interval of receiving. If the time taken to receive a data sentence exceeds this limit, the sentence is denied and an error arises. For example, suppose ZDA, DTM, and GGA are set to be received. If the time taken to receive all ZDA, DTM and GGA exceeds the maximum time interval, all the information is denied and an error is raised.

Page 27: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

21 DOC No. 7ZPNA4013D

4.3.4.2.3. Recording data

Whether or not a sentence is recorded in the VDR/S-VDR is determined by the sentence ID. Any sentence of which ID is different from the specified is discarded and is not recorded in the VDR/S-VDR.

1) Recording item

Select record item from the pull-down menu. Select “Other”, when the item was not found in the menu.

2) Sentence ID

Select a sentence ID from the pull-down menu. Enter the sentence ID, if the sentence was not found in the menu.

Type in maximum 7 characters, including the talker ID

In case of NMEA sentence: The talker ID (2 characters) can be entered along with the sentence ID (3 characters). An uncertain character also can be entered using “?”. Enter as many characters as you like (up to 7 characters). At least, include the sentence ID (3 characters). Examples: setting sentence ID for filtering ZDA sentences of GPS. ( all OK )

▫ GPZDA ▫ GPZDA?? ▫ ??ZDA ▫ ??ZDA??

In case of option unit sentence: A/D : VRXDR DSC (NCT-72/63): ? (Since all sentences are recorded, "?" is used as a wildcard.)

3) Watch The watch on maximum interval of receiving can be set on each sentence. Set the Watch function of each NMEA sentence to enable or disable. The VDR/S-VDR will generate an error when the NMEA sentences set as “Enable” are not received within the set interval time. The VDR/S-VDR will not generate the error alarm when the NMEA sentences set as “Disable” are not received within the interval time.

Enable: [ ] (checked) Disable: [ ] (unchecked)

When the NMEA sentence ID is registered, checks will be entered as a default.

In case of setting to disable

On the equipment that does not transmit NMEA sentences periodically, the setting shall be “Disable”. “Enable” does make sense on the equipment that transmits sentence(s) periodically.

Page 28: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

22 DOC No. 7ZPNA4013D

4.3.4.3. Checking the setup data Confirm that there is no blank in setting data. “Entry” lamp informs the service engineer whether the entry is finished or still some items

(Model, Serial number, etc.) remain. ● (Green): All entries are made. ● (Yellow): Blanks still remain.

Look for a blank item and input a setup data.

4.3.4.4. Transmitting the setup data Transmit the setup data to RCU. • Transmit Click the [SET] button. • Cancel Click the [Close] button.

4.3.4.5. Real Time Monitor

Monitors the real time NMEA sentence data which is collected in the RCU, and verify that the sentence specified by the installation drawings is collected correctly.

1) Procedures

START: Click the [Start] button. * Real time monitor is automatically started at the opening window. STOP: Click the [Stop] button.

2) Selecting the monitor data type. Click the radio button of data type (“RCV Data” /”REC Data”) to monitor.

● “RCV Data”: Monitors all the data that the RCU receives.

The sentence data which is not recorded on the VDR/S-VDR is also displayed.

● “REC data”: Monitors the sentence data which is recorded in the VDR/S-VDR. The sentence which is not recorded is not displayed even when it has been received. The monitored data is displayed by the sentence format currently recorded in the VDR/S-VDR.

Page 29: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

23 DOC No. 7ZPNA4013D

4.3.4.6. Result of diagnosis Confirm that the VDR/S-VDR receives a recording data.

As for the diagnostic result of the [Sensor] section, the result is indicated on the "Diagnosis" lamp immediately after the setting has been completed.

* Regarding the sections other than [sensor], rebooting after transmitting the setup data to RCU

is required, therefore the “Diagnosis” result cannot be indicated with a lamp at setting. ● (Green): The VDR/S-VDR receives a recording data ● (Red): The VDR/S-VDR does not receive a recording data. Check a receiving data by real time monitor. ● (Orange): Under diagnosis * To have the diagnostic function operated, click the [Diagnosis] button on “System” screen.

If the function is not on, the “Diagnosis” lamp is off.

Page 30: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

24 DOC No. 7ZPNA4013D

4.3.5. Detail setup window of GPS (sensor section)

Setup screen of GPS is a screen of exclusive use for connected two GPSs. Sub GPS setting is required when connected two GPSs to one port via a switcher.

4.3.5.1. Identification TAB screen

Set the identification data of connected GPS.

4.3.5.1.1. GPS information

1) Equipment

Enter the name of the connected equipment. (GPS, DGPS, etc)

2) Model Enter the model name of the GPS.

3) Manufacturer Enter the name of the manufacturer of the GPS.

4) Serial No. Enter the serial number of the connected equipment.

* If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.

4.3.5.1.2. Antenna position

Enter the following values for antenna position. Distance from Bow/Stern/Port side/Starboard side to the antenna

Page 31: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

25 DOC No. 7ZPNA4013D

4.3.5.2. GPS Selection TAB screen

Set up the “GPS selection” when the “GPS (main+sub)” is selected as a connection equipment.

1) Switch position Select the logic of dry contact signal which is outputted by a GPS switcher. The GPS switcher is connected to “TB406 PI-3” which is a terminal in the RCU. The VDR/S-VDR records the GPS equipment (main or sub) currently recorded as EVENT.

4.3.5.3. GPS Data TAB screen 1) Date and Time

The sentence of “Date and Time” data is "ZDA" as default. When the GPS does not output ZDA, change the sentence to "RMC" instead.

2)Datum When the GPS does not output DTM, clear the DTM setting.

Page 32: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

26 DOC No. 7ZPNA4013D

4.4. NSK connection setup

4.4.1. Setting connection

CH33 and CH34 of Sensor section are the connection CH with NSK. Enable / Disable of heading data connection can be set up to CH33. Enable / Disable of speed data connection can be set up to CH34. 1) Each channel

Check the check box of connected CH as follows. Enable: [ ] (checked) Disable: [ ] (unchecked)

Check box

Select the subject CH of set up

Click to open detail

window

4.4.2. Starting detail setup The detailed connection setting window of each channel is displayed.

1) Selecting CH Click the radio button of setting sensor channel. 2) Click the [Detail] button on sensor section. Then detail setting window appears.

Page 33: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

27 DOC No. 7ZPNA4013D

4.4.3. Detail setup window of Heading data (CH33)

4.4.3.1. Identification TAB screen

Set an identification data of connected equipment which outputs a Synchro signal or a step signal as heading data. 1) Equipment

Enter the name of the connected equipment. (Gyro, etc)

2) Model Enter the model name of the connected equipment.

3) Manufacturer Enter the name of the manufacturer of the connected equipment.

4) Serial No. Enter the serial number of the connected equipment.

* If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.

Page 34: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

28 DOC No. 7ZPNA4013D

4.4.3.2. Heading TAB screen

4.4.3.2.1. Signal Type

Select Synchro or Step as a signal type.

4.4.3.2.2. Ratio

Select turn ratio from 1, 36, 90, 180 or 360 deg.

4.4.3.2.3. Gray Code

Select Order Direction or Reverse Direction as rotation direction.

4.4.3.2.4. Transmitting a setup data (Caution)

When the setup data of "Signal Type", "Ratio", or "Gray Code" are changed, transmit the setup data to RCU before inputting an initial value of heading. Click the [Set] button, to finalize the renewed data.

* After the data transmission, RCU is rebooted automatically and setting data will become effective.

Page 35: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

29 DOC No. 7ZPNA4013D

4.4.3.2.5. Heading Data

Even when the entry of heading angle is not made from OPU, the initial value of heading can be inputted from Heading TAB screen.

1) Measured Value

The current value of heading is displayed. The value displayed on this screen is the same as the value displayed on OPU.

* Hading value is not displayed if the Real-time monitor has been stopped. Start the Real-time monitor in "Rec data" mode.

2) Initial Value

Click the [Send] button after inputting an initial value. The inputted initial value is registered into the RCU. * "Initial Value" and "Measured Value" should show the same heading value immediately after the screen is

opened. When the correct heading value is displayed, click the [Send] button without inputting an initial value.

3) Checking the heading value

Check that the correct heading value is displayed on the "Measured Value".

Page 36: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

30 DOC No. 7ZPNA4013D

4.4.4. Detail setup window of Ship’s Speed data (CH34)

4.4.4.1. Identification TAB screen

Set an identification data of connected equipment which output a Pulse signal as ship’s speed data. 1) Equipment

Enter the name of the connected equipment. (Speed log, etc.)

2) Model Enter the model name of the connected equipment.

3) Manufacturer Enter the name of the manufacturer of the connected equipment.

4) Serial No. Enter the serial number of the connected equipment.

* If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.

4.4.4.2. Ship’s Speed TAB screen

4.4.4.2.1. Pulse

Select the rate from 100, 160, 200, or 400 pulse/NM.

Page 37: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

31 DOC No. 7ZPNA4013D

4.5. Option unit (NCT-72/63) connection setup In order to record a dry contact signal and an analog signal on VDR/S-VDR, the Digital Signal Converter (DSC: NCT-72/63 option) must be connected to the VDR/S-VDR. Set up the DSC following the procedure described hereunder.

4.5.1. Setting connection CH 13, 14, 15, and 16 can accept the NCT-72/63.

Enable / Disable of the DSC connection can be set up to the above-mentioned channels. 1) Each channel

Check the check box of connected CH as follows. Enable: [ ] (checked) Disable: [ ] (unchecked)

Check box

Select the setup CH Open Detail window

4.5.2. Starting the detail setup The detailed connection setting window of each channel is displayed.

1) Selecting CH Click the radio button for setting sensor channel. 2) Click the [Detail] button on sensor section and the detail setting window appears.

Page 38: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

32 DOC No. 7ZPNA4013D

4.5.3. Selecting a recording data

Select the option unit (NCT-72/63) and recording data according to the following procedure. The initial value for receiving the data of the option unit (NCT-72/63) is set up automatically on the detail setting window.

4.5.3.1. In the case of new setting

Select “Option Unit” from the pull-down menu. Then click the [Next] button.

Select connected equipment from the pull-down menu. • In case of connecting dry contacts Select the “DSC (CH*)”. • In case of connecting dry contacts and analog signals Select the “DSC+A/D (CH*)”

(Optional Analog Conversion Board (CEF-60) must be built in the DSC.)

Click the [Next] button.

Page 39: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

33 DOC No. 7ZPNA4013D

4.5.4. Detail setup window of NCT-72/63

• "Dry Contact" TAB is added as a detailed setting screen of dry contact input. • When “DSC+A/D” is selected, "A/D" TAB is added as a detailed setting screen of analog signal input.

4.5.4.1. Identification TAB screen

Set an identification data of NCT-72/63. 1) Equipment

"DSC" or "DSC+A/D" is entered automatically. The interior of the parentheses is Connection channel/equipment.

2) Model Enter the model name of the connected equipment. (NCT-72/63)

3) Manufacturer Enter the name of the manufacturer of the connected equipment. (JRC)

4) Serial No. Enter the serial number of the connected equipment.

Page 40: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

34 DOC No. 7ZPNA4013D

4.5.4.2. Data TAB screen

According to selection of "DSC" or "DSC+A/D", an appropriate data is entered automatically.

● DSC+A/D

● DSC

4.5.4.3. Transmitting the setup data for NCT-72/63 connection Transmit the setup data for NCT-72/63 connection to the RCU after entering all data on “Identification” screen. Click the [SET] button.

Page 41: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

35 DOC No. 7ZPNA4013D

4.5.5. Detail setup window of dry contact (Dry Contact TAB screen) This is the screen for transmitting and receiving the configuration file of NCT-72/63.

4.5.5.1. Program Version Display of NCT-72/63

Click the [Version] button. The program version of NCT-72/63 is displayed.

In case the program version is not shown, DSC does not communicate with VDR/S-VDR.

4.5.5.2. Receiving the configuration file Receive the configuration file of NCT-72/63. 1) Click the [Receive] button. 2) AT a communication link Monitor display, check that setting data are received. 3) Completion/failure of reception is displayed by a dialog. Verify that the following message appears.

4.5.5.3. Setup of NCT-72/63

Click the [Setup] button and the screen for the NCT-72/63 setup will appear.

Page 42: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

36 DOC No. 7ZPNA4013D

4.5.5.4. Setup screen of sentence data (alarm, door, etc.)

Dry contact data, such as alarm, door (open or close) and others should be changed into NMEA sentences. The screen for creating conversion table file will appear.

In editing not the configuration file that was received from NCT-72/63 but the configuration file saved, point to

“Open” at File menu list.

4.5.5.4.1. Registration of sentence data converted from dry contact signal

Sentence data are set up to each channel which accepts dry contact signal. ● Connection CH

Select a channel which is connected to the dry contact signal.

Page 43: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

37 DOC No. 7ZPNA4013D

● State of a dry contact signal

The condition of the equipment shown by OPEN/CLOSE of a dry contact signal is set up.

1) Alarm Select the inputting dry contact state (OPEN/CLOSE) when the connected equipment is in normal state.

2) Door Select the inputting dry contact state (OPEN/CLOSE) when the connected door is open.

● creating a sentence data

Select each factor which constitutes the sentence data.

1) Dry contact information Select the dry contact information from the pull-down menu of each category according to the connected signal. Although categories are prepared from 0 to 3, the number of category to be set up is automatically determined by the selected data.

Be sure to select a dry contact information from the pull-down menu which can be set up. An unnecessary setup category is not selectable.

Page 44: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

38 DOC No. 7ZPNA4013D

* A selection setup from a tree structure

The tree structure displayed on the left screen shows the dry contact inputs that can be registered. Sentence data can be set up by double-clicking each item.

Selected sentence Double- Click

2) Identification number of a dry contact A signal of the same kind must be identified by respective number. Select the identification number listed in the pull-down menu. Be careful not to double select an identification number otherwise the same sentence data will be created

3) Comment Each sentence can be followed by a comment. Add a comment to each sentence by which a service engineer recognizes what the signal is.

Page 45: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

39 DOC No. 7ZPNA4013D

3) Registering sentence data Click the [SET] button when all categories are selected and comment is inputted. The sentence is created according to the contents of selection and is added to the setup file.

4.5.5.4.2. Deleting and editing a sentence data registered

The sentence registered into the setup file can be deleted. 1) Selecting a sentence

Double-click the sentence displayed on the list. The CH number for deletion is displayed.

2) Deleting a sentence

Click the [Delete] button.

2) Editing a sentence Set up a new sentence data after deletion.

4.5.5.4.3. When All Setup is Completed

When there is no connection to Engine telegraph, move on to the “4.5.5.6”.

Page 46: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

40 DOC No. 7ZPNA4013D

4.5.5.5. Registration screen of sentence data for engine telegraph

This is a screen of exclusive use for Engine telegraph setup.

4.5.5.5.1. Screen change

Click the “Engine telegraph” from “Type” menu.

4.5.5.5.2. Engine telegraph position

Setup an engine telegraph position data according to the following procedure.

1) Selection of “Enable” / “Disable” Select either “Enable (connected)” or “Disable (disconnected)” of the engine telegraph position data by dry contact signals. In case of connecting, click the checkbox.

Page 47: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

41 DOC No. 7ZPNA4013D

2) Selecting the connected dry contact signals On the selecting menu, all the signals of an engine telegraph position can be registered. The contact signal actually connected must be all selected. Check the connection signal.

3) Selecting the connection CH

Select the connection CH of NCT-72/63 from the pull-down menu.

4) Selecting the state of dry contact signal Select a state of the dry contact signal (Open/Close) at "Active state".

2) 4) 3)

4.5.5.5.3. Sub telegraph position

Set up a sub telegraph position data. Setup procedure is the same as “Engine telegraph position”.

4.5.5.5.4. Operation position

Set up an operation position data of engine telegraph.

1) Selection of “Enable” / “Disable” Select either “Enable (connected)” or “Disable (disconnected)” of the operation position data by dry contact signals. In case of connecting, click the checkbox.

Page 48: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

42 DOC No. 7ZPNA4013D

2) Enable setting

Setup procedure is the same as “Engine telegraph position”. 3) Disable setting Select “Other”.

4.5.5.5.5. Order or Response (Status)

Select the sentence type (Order / Response) of engine telegraph signals.

4.5.5.5.6. Engine and Propeller position

Select the position of the engine and the propeller shaft. • Single or on center line • Port • Starboard

4.5.5.5.7. Registration of Engine telegraph sentence data

The NMEA sentence for engine telegraph is registered. 1) ETL sentence identification number

Select the identification number in case of registering two or more ETL sentences. When registering only one sentence, "01" as a default must be selected. To register two or more sentences, select the total number. It can set up from "01" to "04."

2) Registering sentence data Click the [SET] button. The ETL sentence is registered.

Page 49: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

43 DOC No. 7ZPNA4013D

4.5.5.6. All setup is completed

The configuration file created to NCT-72/63 is transmitted when all the setup is completed.

1) Transmit the configuration file. Click the [Send] button. 2) The setup screen is completed and returns to the Transmit/Receive screen of the configuration file. The configuration file is transmitted automatically to the NCT-72/63. 3) Save the configuration file To save the configuration file of NCT-72/63, it should be saved before transmitting the file. Click the [Save As] button, and save the configuration file.

4.5.5.7. Transmitting the configuration file 1) At the communication link Monitor display, check that setting data are transmitted. 2) Completion/failure of reception is displayed in a dialog. Verify that the following message appears. 3) When transmission is incomplete, click the [Send] button again.

Page 50: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

44 DOC No. 7ZPNA4013D

4.5.5.8. Real time monitor of dry contact sentence

Check that the registration and the wiring of a dry contact signal are correct by the Real-time monitor.

4.5.5.8.1. Real Time Monitor

The NMEA sentence can be monitored by the real time monitor on the setting screen. If the following dry contact signal monitor is available, check the sentence with this.

4.5.5.8.2. Dry contact monitor

1) Starting Click the [Monitor] button. 2) Operating

Refer to “7.5”.

Page 51: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

45 DOC No. 7ZPNA4013D

4.5.5.9. Diagnostic result of dry contact signal

Enter a diagnostic result manually. 1) Dialog for entering a diagnostic result Click the [DSC Check] button. The dialog for entering a diagnostic result will appear. 2) Connection of dry contact signals Check that monitor icons (lamp, door) change according to the state of the connected dry contact signals. Enter the diagnostic result using the radio button (Good/No Good). 3) Sentence setup

Check that the logic of a dry contact signal is correct. • Alarm Normal: Green lamp / Abnormal: Red lamp • Door A door icon shows the state of door (Open/Close). Click Good or No Good according to the diagnostic result. 4) Comment

Enter a comment if the result is NG.

Page 52: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

46 DOC No. 7ZPNA4013D

4.5.6. Detail setup window of analog signal (A/D TAB screen)

This is the screen to set up analog signals.

The following data that are inputted on the setup screen of each channel are displayed on this screen.

• Connection signal • Current value • Data unit

4.5.6.1. Setting connection of Analog signal Enable / Disable of each Analog signal connection can be set up.

1) Each channel Check the check box of connected CH as follows.

Enable: [ ] (checked) Disable: [ ] (unchecked)

4.5.6.2. Setting detail setup of Analog signal 1) Starting

Click the [channel] button of detail setup channel.

Page 53: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

47 DOC No. 7ZPNA4013D

4.5.6.2.1. Identification of Analog signal output Equipment

Set an information data of connected Analog signal output equipment. 1) Equipment

Enter the name of the connected equipment.

2) Model Enter the model name of the connected equipment.

3) Manufacturer Enter the name of the manufacturer of the connected equipment.

4) Serial No. Enter the serial number of the connected equipment.

* If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.

4.5.6.2.2. Setup of Analog signal Specifications

Type of signal (Voltage or Current), range and etc. are set by the strap on PCB (ACB: CEF-60). Maintenance software has no effect on them.

4.5.6.2.3. Calculating a coefficient

Set up the parameters to translate the A/D conversion value (%) of the ACB into the real value displayed on the equipment.

1) Selecting CH Select an analog channel to set up.

Page 54: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

48 DOC No. 7ZPNA4013D

2) Setting a minimum value

Operate the analog signal output equipment so that it will output the minimum value.

• STEP1: Input the minimum value displayed on the equipment.

• STEP2: Input the A/D conversion value. Click the [Receive] button. A/D conversion value is inputted automatically. * Manual input is also possible.

• STEP3: Click the [Set] button.

3) Setting a maximum value Operate the analog signal output equipment so that it will output the maximum value.

• STEP4: Input the maximum value displayed on the equipment.

• STEP5: Input the A/D conversion value. Click the [Receive] button. A/D conversion value is inputted automatically. * Manual input is also possible.

• STEP6: Click the [Set] button.

4) Verify the calculated data

Check the conversion formula is correct.

• STEP7: Check that the conversion value on “Check value” and the real value on the equipment are the same.

Click the [Check] button. The converted value is displayed. When the converted value is not correct, repeat from STEP1.

• STEP8: Set the coefficient of the formula. Click the [Apply] button.

Language setting If the Maintenance PC is not Japanese OS or English OS, analog data may not convert real value correctly, depending on language. Please set language to the “English (United States” or the “English (United Kingdom)” in the Control Panel screen of Windows. Refer to "17.3 Language setting for Maintenance PC" about the setting method of language.

Page 55: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

49 DOC No. 7ZPNA4013D

4.5.6.2.4. Setting of Analog signal information

The specification and information of the analog signal are set up. 1) Data unit

Select the data unit of receiving data.

2) Contents of connection data Select the contents of connection data. 3) Conversion formula The coefficients of the conversion formula are inputted automatically.

* Manual input is also possible.

Conversion formula y=A1*10A2x+B1*10B2 y=Equivalent, x=A/D conversion value, A1, A2, B1, B2: Coefficient

4) Analog signal range Select the analog signal input range. This entry has nothing to do with analog-digital conversion. This is simply a record of input condition.

4.5.6.2.5. Setting detail setup of Analog signal

Set up the data after completing all setup. Click the [Set] button.

No. Unit

00 - 01 deg 02 min-1 03 rpm 04 m/s 05 km/s 06 knots

Page 56: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

50 DOC No. 7ZPNA4013D

4.5.6.3. Diagnostic result of analog signal

Enter a diagnostic result manually. 1) Dialog for entering a diagnostic result Click the [A/D Check] button. The dialog for entering a diagnostic result will appear. 2) Connection of analog signals

Check that the A/D-conversion value of the connected analog signal is recorded. Enter the diagnostic result to radio button (Good/No Good). 3) Sentence setup

Check that the conversion value is an appropriate value. Click Good or No Good according to the diagnostic result. 4) Comment

Enter a comment if the result is NG.

Page 57: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

51 DOC No. 7ZPNA4013D

4.5.6.4. Analog Signal Converting Board (CEF-60) setup

The parameters of the following inputs are set up by the strap on PCB. 1) Setting parameter of each channel

Items Parameter Remark Input channel use YES (enable) / NO (disable) Select “YES” for connecting analog signal or

“NO” for not connecting signal. Input signal Voltage Current Chooses the type of signal.

±1V ±5V 4-20mA Range ±10V

Chooses the range of input signal. Set up the range according to the type of signal.

2) Setting strap on the PCB (CEF-60) CH0 CH1 CH2 CH3 CH4 CH5 CH6 CH7

Page 58: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

52 DOC No. 7ZPNA4013D

4.6. Option unit (NCT-52A) connection setup In order to record a synchro signal for rudder angle and wind direction and an analog signal for wind speed on VDR/S-VDR, the NAV-Interface unit (NAV-I/F: NCT-52A option) must be connected to the VDR/S-VDR. Set up the NAV-I/F following the procedure described hereunder.

4.6.1. Setting connection CH 13, 14, 15, and 16 can accept the NCT-52A.

Enable / Disable of the NAV-I/F connection can be set up to the above-mentioned channels. 1) Each channel

Check the check box of connected CH as follows. Enable: [ ] (checked) Disable: [ ] (unchecked)

Check box

Select the setup CH Open Detail window

4.6.2. Starting the detail setup The detailed connection setting window of each channel is displayed.

1) Selecting CH Click the radio button for setting sensor channel. 2) Click the [Detail] button on sensor section and the detail setting window appears.

Page 59: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

53 DOC No. 7ZPNA4013D

4.6.3. Selecting a recording data

Select the option unit (NCT-52A) and recording data according to the following procedure. The initial value for receiving the data of the option unit (NCT-52A) is set up automatically on the detail setting window.

4.6.3.1. In the case of new setting

Select “Option Unit” from the pull-down menu. Then click the [Next] button.

Select connected equipment from the pull-down menu. • In case of connecting NCT-52A Select the “NAV-I/F (NCT-52A)”.

Click the [Next] button.

Page 60: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

54 DOC No. 7ZPNA4013D

4.6.4. Detail setup window of NCT-52A

• "NAV-I/F" TAB is added as a detailed setting screen of NAV-I/F input.

4.6.4.1. Identification TAB screen

● NAV-I/F Set an identification data of NCT-52A. 1) Equipment

"NAV-I/F" is entered automatically.

2) Model "NCT-52A" is entered automatically.

3) Manufacturer "JRC" is entered automatically.

● CH1

Set an information data of rudder angle output equipment. 1) Contents

"Rudder" is entered automatically. It cannot be modified. * Synchro signal for rudder angle has to be connected to the CH1 of NCT-52A. 2) Equipment

Enter the name of the connected equipment.

3) Model Enter the model name of the connected equipment.

Page 61: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

55 DOC No. 7ZPNA4013D

4) Manufacturer Enter the name of the manufacturer of the connected equipment.

5) Serial No. Enter the serial number of the connected equipment.

* If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.

● CH2

Set an information data of wind direction output equipment. 1) Contents

"Wind Direction" is entered automatically. It cannot be modified. * Synchro signal for wind direction has to be connected to the CH2 of NCT-52A. The following items are same as that of ch1 setting. ● CH3

Set an information data of wind speed output equipment. 1) Contents

"Wind Speed" is entered automatically. It cannot be modified. * Analog signal (1-5V or 4-20mA) for wind speed has to be connected to the CH3 of NCT-52A. The following items are same as that of ch1 setting.

4.6.4.2. Data TAB screen

According to selection of "NAV-I/F", an appropriate data is entered automatically.

Page 62: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

56 DOC No. 7ZPNA4013D

4.6.4.3. Transmitting the setup data for NCT-52A connection Transmit the setup data for NCT-52A connection to the RCU after entering all data on “Identification” screen. Click the [SET] button.

4.6.5. Detail setup window of NAV-I/F (NAV-I/F TAB screen) This is the screen to set up parameters for converting Synchro and Analog signal to real value data.

"Rudder angle", "wind direction", and "wind speed" data from NCT-52A are displayed on real time. Verify the converted value after all setup. When the converted value is not correct, retry a setup of parameters.

Page 63: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

57 DOC No. 7ZPNA4013D

4.6.5.1. Setting parameters for converting to rudder angle data Click the [CH1] button.

The screen to set up parameters for converting Synchro signal to rudder angle data is displayed.

● Rudder Setting Set the parameters for converting Synchro signal to rudder angle data.

Step 1) Control the actual rudder, so that the rudder angle value is set to "00.0." Step 2) Select ratio from x2, x3, x4 or x5. Step 3) Click the [Initialize] button. Wait for 5 seconds until initializing of NCT-52A is completed. Step 4) Click the [Adjust] button. Step 5) Verify that the correct rudder angle value is displayed on the “Check value”.

● NAV-I/F data The setup parameters to NCT-52A are displayed. Click the [Read] button. Each setup parameters are displayed.

Page 64: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

58 DOC No. 7ZPNA4013D

4.6.5.2. Setting parameters for converting to wind direction data Click the [CH2] button.

The screen to set up parameters for converting Synchro signal to wind direction data is displayed.

● Wind Direction Setting Set the parameters for converting Synchro signal to wind direction data.

Step 1) Control the anemometer to stabilize the value of the wind direction. Step 2) Select direction from Order or Reverse. Step 3) Click the [Initialize] button. Wait for 5 seconds until initializing of NCT-52A is completed. Step 4) Input a wind direction value displayed on the anemometer. Step 5) Click the [Adjust] button. Step 6) Verify that the correct wind direction value is displayed on the “Check value”.

● NAV-I/F data The setup parameters to NCT-52A are displayed. Click the [Read] button. Each setup parameters are displayed.

Page 65: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

59 DOC No. 7ZPNA4013D

4.6.5.3. Setting parameters for converting to wind speed data Click the [CH3] button.

The screen to set up parameters for converting Analog signal to wind speed data is displayed.

● Wind Speed Setting Set the parameters for converting Analog signal (1-5V or 4-20mA) to wind speed data.

Step 1) Input a wind speed value on 1V (or 4mA) anemometer outputting. Step 2) Input a wind speed value on 5V (or 20mA) anemometer outputting. Step 3) Click the [Adjust] button. Verify that the correct wind speed value is displayed on the “Check value”. Language setting

If the Maintenance PC is not Japanese OS or English OS, analog data may not convert real value correctly, depending on language. Please set language to the “English (United States” or the “English (United Kingdom)” in the Control Panel screen of Windows. Refer to "17.3 Language setting for Maintenance PC" about the setting method of language.

● NAV-I/F data

The setup parameters to NCT-52A are displayed. Click the [Read] button. Each setup parameters are displayed.

4.6.5.4. Real time monitor of NAV-I/F unit outputting sentence Check that the outputting sentence of NAV-I/F unit by the Real-time monitor.

4.6.5.4.1. Real Time Monitor

The NMEA sentence can be monitored by the real time monitor on the setting screen.

● Sentence format $ANADATA, “Rudder angle data”, “Wind direction data”, “Wind speed data”……

Page 66: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

60 DOC No. 7ZPNA4013D

4.6.5.5. Diagnostic result of NAV-I/F data Enter a diagnostic result manually. 1) Dialog for entering a diagnostic result Click the [NAV-I/F Check] button. The dialog for entering a diagnostic result will appear. 2) Receiving sentence data from NAV-I/F

Check that the “ANADATA” sentence data from NAV-I/F is recorded. Enter the diagnostic result to radio button (Good/No Good). 3) Converting value

Verify that the converting value is correct. Enter the diagnostic result to radio button (Good/No Good). 4) Comment

Enter a comment if the result is NG.

Page 67: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

61 DOC No. 7ZPNA4013D

4.7. Radar connection setup

4.7.1. Setting connection

Enable / Disable of Radar connection and the FGB can be set up. 1) Each channel

Check the check box of “Sub” in case of connected two Radars. Enable: [ ] (checked) Disable: [ ] (unchecked)

* Check on “Main” cannot be cancelled. 2) Frame Grabber Board (FGB)

• S-VDR (JCY-1850) FGB is an option board in the S-VDR. Therefore the default setting of FGB is “disable”. When the FGB is installed into the RCU, Check the check box of “FGB”

• VDR (JCY-1800) ・ VDR(JCY-1800)

FGB is a standard board in the VDR. Therefore the default setting of FGB is “enable” and the check cannot be cancelled.

4.7.2. Starting detail setup Click the [Detail] button on Radar section then the detail setup window appears.

Page 68: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

62 DOC No. 7ZPNA4013D

4.7.3. Detail setup window of Radar

4.7.3.1. Identification TAB screen

4.7.3.1.1. Identification data of Radar

Set an identification data of connected Radar.

1) Model

Enter the model name of the connected equipment.

2) Manufacturer Enter the name of the manufacturer of the connected equipment.

3) Serial No. Enter the serial number of the connected equipment.

* If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.

Page 69: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

63 DOC No. 7ZPNA4013D

4.7.3.1.2. Setup file of FGB

The setup file of FGB can be downloaded and uploaded. The setup file of FGB is saved in the “FGB_Util¥CKA137-JCY1800” folder hung under Install folder of the maintenance software. The Radar model or image specification is used as the file name. Select a correct setup file referring to the following instructions.

● Radar model Cap2-JMA9900-1800.txt

Cap2 "2" means this setup file is for FGB: CKA -137. Reference: When “Cap” is not suffixed by 2 (i.e; Cap-..), the setup file is for CKA-129.

JMA9900 Radar model 1800 “1800” means the setup file is for JCY-1800/1850.

Reference: “1700” stands for JCY-1700/S. ● VESA Cap2-1024x768-60Hz-1800.txt

Cap2 "2" means this setup file is for FGB: CKA -137. Reference: When “Cap” is not suffixed by 2 (i.e; Cap-..), the setup file is for CKA-129.

1024x768 Image Resolution 60Hz Refresh rate 1800 “1800” means the setup file is for JCY-1800/1850.

Reference: “1700” stands for JCY-1700/S.

4.7.3.1.3. Two Radar images recording mode

This is the recording mode applied when two radars are hooked up to the VDR/S-VDR. 1) Recording single image switching two radars This is called “switching record mode”, Standard recording method. Select the “Single Record by Switch” from the pull-down menu. 2) Recording both images

The “dual record mode” can be selected as an option. To adopt the option, larger storage of memory of Capsule and CF card is required. Both Radar images can be recorded at a time with the extended memory.

Select “Dual Record” from the pull-down menu.

4.7.3.1.4. In case of using Radar Interface Unit

The Radar Interface Unit should be installed, when the display resolution of connected Radar unit is UXGA. 1) Setting the mode of Radar interface unit

• When the Radar Interface Unit is installed, select the “NWP-46” from the pull-down menu. • Enter the serial number of NWP-46.

*Caution: The Radar interface unit has a cooling fan. In case “None” is selected, Fan alarm is not informed even

when the alarm arises.

Page 70: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

64 DOC No. 7ZPNA4013D

4.7.3.2. Radar Selection TAB screen

4.7.3.2.1. Select signal

When two radars are connected and VDR/S-VDR records one of the two radar images by switching, set the switching signal. 1) Dry contact

Select “Dry contact”, when recording channel is switched by dry contact signals outputted from a switcher. 2) NMEA

Select “NMEA”, when recording channel is switched by the PJRC sentence outputted from JRC radar.

3) None (Auto) Select “None”, when the switching signal is not connected. Recording channel is switched by detecting a RGB signal. When radar images are sent from both radars, the image on CH1 is recorded.

4.7.3.2.2. NMEA

Sensor channel which receives PJRC sentence for switching is set up automatically. Verify that a Radar connection channel is displayed.

4.7.3.2.3. Dry Contact

Select the logic of the dry contact which is outputted by a switcher. AUTO mode is selected when both dry contact signals are of the same logic.

Logic table of dry contact PI_1 PI_2 MODE OPEN OPEN AUTO OPEN CLOSE CH1 record CLOSE OPEN CH2 record CLOSE CLOSE -

* The switcher is not an optional unit of VDR/S-VDR.

PI_1

PI_2

Page 71: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

65 DOC No. 7ZPNA4013D

4.7.3.3. Real Time Monitor

Monitors the real time Radar Image which is recorded to the VDR/S-VDR. This is to check the image recording operation.

1) Selecting the monitor CH

The image received by CH1 is displayed on TAB “Image 1” screen. The image received by CH2 is displayed on TAB “Image 2” screen.

2) Starting to monitor START: Click the [Start] button. STOP: Click the [Stop] button.

3) Diagnosis Have a look the radar picture and judge the quality by yourself. Then click the [Image Quality check] button. Sort the acceptable or better picture to “Good” and the questionable

or worse to “No Good”.

Page 72: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

66 DOC No. 7ZPNA4013D

● Judging the image quality.

Click “Good” or “No Good” accordingly. If the latter is the case, write a comment.

* Click the [Help] button to have an advice on judging the Image quality.

* When a location gap of recording image exists or the focus of recording image is poor, adjust the value of the configuration file of the FGB referring to Chapter 11.

4.7.3.4. Checking the setup data Confirm that there is no blank in setting data. 1) Entry lamp

Error in setting entry (Model, Serial number, etc.) is warned by the “Entry” lamp. ● (Green): All entries are made. ● (Yellow): A blank remains.

Look for the blank item and input the setup data. 2) Image Quality lamp Result of judgment on the image quality is indicated by the “Image Quality” lamp. ● (Yellow): The image quality is not judged yet.

Open the "Image quality check" screen and enter the result of judgment. ● (Green): The image quality is judged good.

● (Red): The image quality is judged no good.

Page 73: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

67 DOC No. 7ZPNA4013D

4.7.3.5. Transmitting the setup data Transmit the setup data to the RCU. • Transmit Click the [SET] button. • Cancel Click the [Close] button.

4.7.3.6. Result of diagnosis

As for the diagnosis of the [Radar] section, the result is indicated by the "Diagnosis" lamp. ● (Green): Result of diagnosis is good. ● (Red): Result of diagnosis is not good. ● (Orange): Under diagnosis

* Setting of modified data of the "Radar" section is validated after the reboot of RCU. Therefore, when a setup data is changed, do not refer to the diagnostic result made before rebooting the RCU.

* The diagnostic lamp is displayed also on the SYSYTEM screen.

Click the [Reboot] button on the SYSTEM screen after completing setup, and check the diagnostic lamp of the SYSTEM screen.

The meaning of each lampis; 1) FGB

The Ethernet communication link condition of the Frame Grabber Board (FGB) and the Main Control Board (MCB)

2) Main The RGB signal from the main radar 3) Sub The RGB signal from the sub radar * The diagnostic function needs to be in operation. A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating.

A diagnostic function can be started with the [Diagnosis] button on “SYSTEM” screen.

Page 74: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

68 DOC No. 7ZPNA4013D

4.8. Microphone connection setup

4.8.1. Setting connection

Enable / Disable of each Microphone connection can be set up. 1) Each channel

Click the check box of connected CH as follows. Enable: [ ] (checked) Disable: [ ] (unchecked)

Opening detail window

Check box

4.8.2. Starting detail setup Click the [Detail] button on Microphone section then the detail setup window appears.

Page 75: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

69 DOC No. 7ZPNA4013D

4.8.3. Detail setup window of Microphone

4.8.3.1. Identification TAB screen

Set an identification data of connected Microphone.

1) Type Select an indoor type or a waterproof type. 2) Place

Enter the location where the microphone is installed.

3) Serial No. Enter the serial number of the Microphone unit.

• Serial number: XXXXnnn 4) Model

Enter the model name of the connected Microphone. [Default setting data] Indoor type: NVT-161 Waterproof type: NVT-162

Page 76: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

70 DOC No. 7ZPNA4013D

4.8.3.2. Real Time Monitor

Monitors the real time audio of Microphones that is recorded in the VDR/S-VDR to check the operation.

Caution: Audio data is a mixture of triple input from each Microphone. For checking that each Microphone is

correctly working, connects only one Microphone to monitor.

1) Selecting the monitor CH Select a monitor channel with a radio button.

2) Starting monitor START: Click the [Play] button. STOP: Click the [Stop] button. 3) Volume

Adjust the sound volume by a slide bar. Caution: When sound does not come out from the loudspeaker, check whether or not the speaker output of PC is

OFF or sound volume is minimum. 4) Diagnosis Listen to the audio and judge the quality by yourself. Click the [Audio Quality check] button.

Judge the audio quality on microphone 1-3, 4-6 and 7-9 respectively. Click “Good” or “No Good” accordingly. If the latter is the case, write a comment.

* Click the [Help] button to have an advice on judging the Audio quality.

Page 77: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

71 DOC No. 7ZPNA4013D

4.8.3.3. Checking the setup data Confirm that there is no blank in setting data. 1) Entry lamp

Error in setting entry (Model, Serial number, etc.) is warned by the “Entry” lamp. ● (Green): All entries are made. ● (Yellow): A blank remains.

Look for the blank item and input the setup data. 2) Audio Quality lamp Result of judgment on the audio quality is indicated by the “Audio Quality” lamp. ● (Yellow): The audio quality is not judged yet.

Open the "Audio quality check" screen and enter the result of judgment. ● (Green): The audio quality is judged good.

● (Red): The audio quality is judged no good.

4.8.3.4. Transmitting the setup data Transmit the setup data to the RCU. • Transmit Click the [SET] button. • Cancel Click the [Close] button.

Page 78: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

72 DOC No. 7ZPNA4013D

4.8.3.5. Result of diagnosis

As for the diagnosis of the [Microphone] section, the result is indicated by the "Diagnosis" lamp.

● (Green): Result of diagnosis is good. ● (Red): Result of diagnosis is not good. ● (Orange): Under diagnosis

* Setting of modified data of the " Microphone " section is validated after the reboot of RCU. Therefore, when a setup data is changed, do not refer to the diagnostic result made before rebooting the RCU.

* The diagnostic lamp is displayed also on the SYSYTEM screen.

Click the [Reboot] button on the SYSTEM screen after completing setup, and check the diagnostic lamp of the SYSTEM screen.

The meaning of each lampis;

1) MIC1-9 The result of Microphone test

2) ARB The operating state of data I/F of the Audio Recording Board (ARB) and the Main

Control Board (MCB) * The diagnostic function needs to be operation.

A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating. A diagnostic function can be started with the [Diagnosis] button on “SYSTEM” screen.

Page 79: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

73 DOC No. 7ZPNA4013D

4.9. VHF connection setup

4.9.1. Setting connection

Enable / Disable of each VHF transceiver connection can be set up. 1) Each channel

Check the check box of connected CH as follows. Enable: [ ] (checked) Disable: [ ] (unchecked)

Click to open the detail window

Check box

4.9.2. Starting detail setup The detailed setup window of VHF transceiver is displayed. Click the [Detail] button on VHF section, the detail setup window appears.

4.9.3. Detail setup window of VHF

Page 80: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

74 DOC No. 7ZPNA4013D

4.9.3.1. Identification TAB screen

Set an identification data of connected VHF transceiver.

1) Model Enter the model name of the connected equipment.

2) Manufacturer Enter the name of the manufacturer of the connected equipment.

3) Serial No. Enter the serial number of the connected equipment.

* If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial No. column.

4) Place Please select the equipment place of VHF from the pull-down menu.

4.9.3.2. Real time monitor

Monitors the real time audio of VHF transceivers that is recorded in the VDR/S-VDR to check the operation.

Caution: Audio data is a mixture of triple input from each VHF transceiver. For checking that each VHF

transceiver is correctly working, connects only one VHF transceiver to monitor.

1) Starting monitor START: Click the [Play] button. STOP: Click the [Stop] button. 2) Volume

Adjust sound volume by a slide bar. Caution: When sound does not come out from the loudspeaker, check whether or not the speaker output of PC is

OFF or sound volume is minimum. 4) Diagnosis Listen to the audio and judge the quality by yourself. Click the [Audio Quality check] button.

Judge the audio quality on VHF transceiver 1-3. Click “Good” or “No Good” accordingly. If the latter is the case, write a comment.

* Click the [Help] button to have an advice on judging the Audio quality.

Page 81: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

75 DOC No. 7ZPNA4013D

4.9.3.3. Checking the setup data

Confirm that there is no blank in setting data. 1) Entry lamp Error in setting entry (Model, Serial number, etc.) is warned by the “Entry” lamp. ● (Green): All entries are made. ● (Yellow): A blank remains.

Look for the blank item and input the setup data. 2) Audio Quality lamp Result of judgment on the audio quality is indicated by the “Audio Quality” lamp. ● (Yellow): An audio quality is not judged yet.

Open the "Audio quality check" screen and enter the result of judgment. ● (Green): The audio quality is judged good.

● (Red): The audio quality is judged no good.

4.9.3.4. Transmitting the setup data Transmit the setup data to the RCU. • Transmit Click the [SET] button. • Cancel Click the [Close] button.

4.9.3.5. Result of diagnosis

As for the diagnosis of the [VHF] section, the result is indicated by the "Diagnosis" lamp. ● (Green): Result of diagnosis is good. ● (Red): Result of diagnosis is not good. ● (Orange): Under diagnosis

* Setting of modified data of the "VHF" section is validated after the reboot of RCU.

Therefore, when a setup data is changed, do not refer to the diagnostic result made before rebooting the RCU.

* The diagnostic lamp is displayed also on the SYSYTEM screen. Click the [Reboot] button on the SYSTEM screen after completing setup, and check the diagnostic lamp of the SYSTEM screen.

The meaning of each lampis;

1) ARB The operating state of data I/F of the Audio Recording Board (ARB) and the Main Control Board (MCB) * The diagnostic function needs to be operation. A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating.

A diagnostic function can be started with the [Diagnosis] button on “SYSTEM” screen.

Page 82: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

76 DOC No. 7ZPNA4013D

4.10. VDR/S-VDR system setup

4.10.1. Starting the detail setup

The detailed setup window of VDR/S-VDR is displayed. Click the [Detail] button on VDR section, the detail setup window is displayed.

4.10.2. Detail setup window of VDR VDR/S-VDR

Page 83: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

77 DOC No. 7ZPNA4013D

4.10.2.1. Identification TAB screen

4.10.2.1.1.Ship’s Identification

Enter following ship’s identification data. Ship’s name IMO number.

4.10.2.1.2.Q’ty

Entries made here are used by the Playback software. Enter the values.

4.10.2.1.3. VDR Identification

Enter the VDR/S-VDR identification data. 1) Approval No.

Enter the type approval number given by the ship’s class. 2) JRC shipping order

Enter the shipping order number and the serial number of the RCU. 3) Serial No.

Enter the serial number of the installed units that constitutes VDR/S-VDR.

Page 84: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

78 DOC No. 7ZPNA4013D

4.10.2.2. Register Information TAB screen

4.10.2.2.1. Register information

Registration information entered on the Log-in screen is displayed. Registration information which is stored in the RCU is displayed on receiving the configuration data. Registration information is updated to the data entered on the "Log in" screen after setting up.

1) Initial The “Initial” means the setup in the JRC Mitaka factory. The maintainer name, company name, and the date & time (UTC) are automatically registered.

2) Amendment The “Amendment” means the setup on board. The maintainer name, company name, and the date & time (UTC) are automatically registered.

Page 85: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

79 DOC No. 7ZPNA4013D

4.10.2.3. Maintenance TAB screen

4.10.2.3.1. Battery

The expiry date of the battery is displayed. Enter the new expiry date of the battery, when you exchange the battery. The expiry date of the battery is indicated on the battery label. If the expiry date is approaching (i.e. the battery has to be replaced within a year), the message “REPLACE BATTERY BEFORE: Year/Month” flickers red as an alarm

4.10.2.3.2. FAN

The expiry date of the two cooling fans in the PSU of RCU is displayed. Enter the new expiry date of the cooling fans, when you exchange two cooling fans. The life of cooling fans is four years. If the expiry date is approaching (i.e. the fans has to be replaced within a year), the message “REPLACE FAN BEFORE: Year/Month” flickers red as an alarm

Page 86: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

80 DOC No. 7ZPNA4013D

4.10.2.3.3. Beacon of capsule

Enter an information data of Beacon.

1) Serial No. Enter the serial number of the capsule.

2) Next Replacement

The expiry date of the battery in the beacon of capsule is displayed. Enter the new expiry date of the battery in the beacon, when you exchange the beacon unit. The expiry date of the battery is indicated on the beacon label. If the expiry date is approaching (i.e. the battery has to be replaced within a year), the message “REPLACE BEACON BEFORE: Year/Month” flickers red as an alarm

4.10.2.3.4.Blackout test

Check whether or not the VDR/S-VDR is operable even in a blackout.

1) Starting blackout test Click the [Test Start] button. Keep the [BLACKOUT TEST] switch on the panel of PSU in the RCU passed for 5 seconds. The result will be displayed on the “Test result” lamp.

2) Result of diagnosis A result is displayed on the “Test result” lamp.

● (Green): Result of diagnosis is good. ● (Red): Result of diagnosis is no good. ● (Orange): Under diagnosis Whether the AC power is on or off is indicated in the “Status” window.

Page 87: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

81 DOC No. 7ZPNA4013D

4.10.2.4. Software Version TAB screen

4.10.2.4.1. System Version

The software version of JCY-1800/1850 system is displayed.

4.10.2.4.2.Maintenance number

The Maintenance number (an intrinsic firmware number of the circuit board) of each unit (PCB) is displayed. Report all the Maintenance number for repairing.

Page 88: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

82 DOC No. 7ZPNA4013D

4.10.2.5. PCB ID TAB screen

4.10.2.5.1. PCB Serial No.

The serial number of each PCB is displayed. In case of replacing a PCB, enter the serial number of the new PCB which is installed into a unit.

• Option unit (DSC: NCT-72/63) When the DSC is connected to the RCU, the PCB serial number of DSC can be inputted * Report the serial number of PCB which is replaced for repairing.

Page 89: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

83 DOC No. 7ZPNA4013D

4.10.2.6. Option TAB screen

4.10.2.6.1. NSK (Connection)

Check the check box of the “NSK (CH33, 34)” when a Heading data or ship’s speed data is recorded via NSK in VDR/S-VDR.

1) Setting

• VDR: The NSK-I/F board is an option board. Click “NSK” box when installing the NSK-I/F board newly into the RCU.

• S-VDR: The NSK-I/F board is a standard component. The box has already been checked as default.

2) System window

When the “NSK (CH33, 34)” is checked, NSK section is displayed in the System window.

NSK connection channel

4.10.2.6.2.Outputting alarm sentence (VDR System Status)

VDR/S-VDR can output error information from serial port. This function is activated when other equipment requires receiving serial data from VDR/S-VDR.

1) Setting

• COM: Check the check box of the COM. •CH: Select a serial port for outputting the serial data From the CH13 to CH16 are selectable ports. The CH which connected the option unit (Dry contact / Analog data) is not

selectable. * Caution

Set up this function after setting up the option unit connection. (Refer to 4.5.)

Page 90: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

84 DOC No. 7ZPNA4013D

4.10.2.6.3. Adding of RMB (Remote Maintenance System)

When additionally installing RMB into S-VDR, set it according to the following steps.

Note) For more detailed setting method, refer to the installation guide accompanied to the RMB kit (NZK-1850).

1) Setup operation ・RMB : Check the checkbox of RMB ・[Apply] button: Click [Apply] button.

The configuration data required for adding RMB is sent, and then S-VDR reboots automatically.

*Note

If RMB add-on setting is mistakenly done, uncheck the checkbox of RMB and click [Apply] button. The configuration data without the RMB installation is sent, and S-VDR restores the condition before adding RMB.

2) Registering RMB serial number Open “PCB ID” tab, and then register serial number assigned to the RMB PCB.

Page 91: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

85 DOC No. 7ZPNA4013D

4.10.2.7. PI-1 to 3 TAB screen

4.10.2.7.1.Internal Dry Contact

General dry contact signals can be inputted, and they can be recorded as NMEA sentence data. The number of dry contacts must be three or less. Set up the respective sentence according as the dry contact is on or off.

Caution: The dry contact signals for switching Radars and switching GPSs are connected to these input ports.

When the ports are occupied by the switching signals, these ports cannot be used for general dry contact signal entries.

4.10.2.7.2.Setup

1) Enable/Disable Enable / Disable of each PI port connection can be set up.

Check the check box of the connected port.

2) Header of sentence data Enter the header of output sentence data.

3) OPEN sentence data

The sentence data outputted when a dry contact opens is inputted. Enter the sentence data following the header.

4) CLOSE sentence data

The sentence data outputted when a dry contact closes is inputted. Enter the sentence data following the header.

4.10.2.7.3.Real time monitor

The real time sentence data recorded can be monitored. Make or break the contact as a try and verify that the sentence displayed repeats the try accordingly.

Page 92: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

86 DOC No. 7ZPNA4013D

4.10.2.8. Checking the setup data Confirm that there is no blank in setting data. 1) Entry lamp Error in setting entry is warned by the “Entry” lamp. ● (Green): All entries are made. ● (Yellow): A blank remains.

Look for the blank item and input the setup data.

4.10.2.9. Transmitting the setup data Transmit the setup data to the RCU. • Transmit Click the [SET] button. • Cancel Click the [Close] button.

4.10.2.10. Result of diagnosis (Blackout test) As for the diagnosis of the [VDR] section, the result is indicated by the "Diagnosis" lamp.

● (Green): Result of diagnosis is good. ● (Red): Result of diagnosis is not good. ● (Orange): Under diagnosis

* Setting of modified data of the "VDR" section is validated after the reboot of RCU.

Therefore, when a setup data is changed, do not refer to the diagnostic result made before rebooting the RCU.

* The diagnostic lamp is displayed also on the SYSYTEM screen. Click the [Reboot] button on the SYSTEM screen after completing setup, and check the diagnostic lamp of the SYSTEM screen.

* The diagnostic function needs to be operation.

A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating. A diagnostic function can be started with the [Diagnosis] button on “SYSTEM” screen.

Page 93: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

87 DOC No. 7ZPNA4013D

4.11. Capsule setup

4.11.1. Starting detail setup

The detailed setup window of Capsule is displayed. Click the [Detail] button on Capsule section, a detail setup window appears.

4.11.2. Detail setup window of capsule

4.11.2.1. Identification TAB screen Set an identification data of Capsule.

1) Model

Select a model name from the pull down menu. The option model means a capsule of large storage capacity (3Gbyte). Two Radar images can be recorded at a time when this option is selected.

2) Serial No. Enter the serial number of the connected equipment.

Page 94: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

88 DOC No. 7ZPNA4013D

4.11.2.2. Checking the setup data Confirm that there is no blank in setting data. 1) Entry lamp Error in setting entry is warned by the “Entry” lamp. ● (Green): All entries are made. ● (Yellow): A blank remains.

Look for the blank item and input the setup data.

4.11.2.3. Transmitting the setup data Transmit the setup data to the RCU. • Transmit Click the [SET] button. • Cancel Click the [Close] button.

4.11.2.4. Result of diagnosis As for the diagnosis of the [Capsule] section, the result is indicated by the "Diagnosis" lamp. An state of Ethernet communication link with the RCU and the capsule is diagnosed.

● (Green): Result of diagnosis is good. ● (Red): Result of diagnosis is no good. ● (Orange): Under diagnosis

* Setting of modified data of the "Capsule" section is validated after the reboot of RCU. Therefore, when a setup data is changed, do not refer to the diagnostic result made before rebooting the RCU.

* The diagnostic lamp is displayed also on the SYSYTEM screen.

Click the [Reboot] button on the SYSTEM screen after completing setup, and check the diagnostic lamp of the SYSTEM screen.

* The diagnostic function needs to be operating.

A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating. A diagnostic function can be started with the [Diagnosis] button on “SYSTEM” screen.

Page 95: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation CheckJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

89 DOC No. 7ZPNA4013D

4.12. System Configuration File

4.12.1. File open The VDR/S-VDR can be set up by opening a configuration file. (Not Receiving) Click “Open” in the “File” menu and select the configuration file to open.

4.12.2. File save The system configuration data in the Maintenance software can be saved to a file. Click the “Save” in the “File” menu and input a file name to save.

Page 96: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

4. Installation, Setup, and Operation Check JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

90 DOC No. 7ZPNA4013D

This page left blank intentionally

Page 97: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

5. SYSTEM ScreenJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

91 DOC No. 7ZPNA4013D

5. SYSTEM Screen

On the SYSTEM screen, the connection setup, the operating state of VDR/S-VDR system and the condition (Good/No Good) of received signal can be verified.

Functions on the SYSTEM screen

● Enable / Disable of each connection channel and the setup of connection interface ● Detail setting of each connection channel ● Reference to and registration of information of detail setup VDR/S-VDR ● Warning to wrong entry of setting ● Display of the receiving state (OK/NG) of each serial channel ● Display of the state (OK/NG) of VDR/S-VDR operation: Radar, Microphone, VHF, Capsule ● Display of the System status information of each section: Radar, Microphone, VHF, Capsule

Page 98: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

5. SYSTEM Screen JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

92 DOC No. 7ZPNA4013D

5.1. Buttons commonly used on the SYSTEM screen Here, how to operate the common buttons on the SYSTEM screen is described. 1) [Receive] button

The Maintenance software receives the system configuration data of RCU Click the [Receive] button, progress of data reception is displayed on the progress bar placed at the bottom of the screen. The display of system screen will be updated by the received system configuration data.

2) [Diagnosis] button Diagnosis function is engaged by this button. Click the [Diagnosis] button then diagnosis function starts and the button burns green. 3) [Set] button

This button is used to set up each system configuration data. Click the [Set] button then all the configuration data is transmitted to the RCU.

* The button registers the system configuration data of each section in the “detail setup” window to RCU. It is

unnecessary to use the [Set] button on the System screen when the detail window is opened to revise the setup data. Use the [Set] button on the System screen when all the system configuration data should be revised or only the individual check is changed.

4) [Reboot] button

The button triggers to reboot the RCU. Click the [Reboot] button then the RCU will be restarted by renewed system configuration. Wait until the communication link of Maintenance software and RCU will be reestablished.

5) [All Default] button

This button reconfigures the system back to the default setting as the standard connection of the VDR/S-VDR.

Page 99: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

5. SYSTEM ScreenJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

93 DOC No. 7ZPNA4013D

6) [Alarm Mute] button

The [Alarm Mute] button is used to suspend the function of ALARM BUZZER of OPU. Click the [Alarm Mute] button then even when an error arises during the maintenance, the ALARAM BUZZER does not sound. The [Alarm Mute] button is lit green while the mute function is on. Click the green [Alarm Mute] button to cancel the Mute function. Do not forget to release the mute function before quitting the Maintenance software.

7) [ACK] button

The [ACK] button on this screen works in the same way as the [ACK] button on the OPU. The [ACK] button is used to silence the ALARM BUZZER. In case multiple errors arose, presses the button as many times as the errors were raised.

5.2. Sensor section The equipment information and recording data registered by detailed setup of sensor is displayed.

Click the [Unit ID / Record item]/ [Manufacturer / Model] button. The information changes accordingly. * The ID means the error code which is displayed on the OPU. Change of display

Page 100: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

5. SYSTEM Screen JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

94 DOC No. 7ZPNA4013D

5.3. Indicating the modified setup On the SYSTEM screen, when the setup data have been modified, the altered items are indicated by red. Besides, a button that is to validate a modification is also lit red.

5.3.1. Connection setup, [SET] button If a box is checked, the color is changed from black to red and the button also blinks red.

The red color means the item data has not been transmitted to the RCU yet. The indications are returned from red to gray after the revised data has been transmitted to the RCU. Blinks in red

5.3.2. [Reboot] button The [Reboot] button blinks red prompting the maintainer to reboot RCU to have RCU operated with the modified setup data. Click the [Reboot] button. The indications will be returned from red to gray after rebooting RCU.

Blinks in red

Caution: Even when the [Reboot] button blinks red, it is not necessary to click the button immediately.

When all the setup is completed, reboot the RCU, and check the operation of the VDR/S-VDR.

Page 101: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

5. SYSTEM ScreenJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

95 DOC No. 7ZPNA4013D

5.4. Diagnosis function

5.4.1. Diagnosis button The received data from connected equipment and the operating state of the VDR/S-VDR are diagnosed, and the result is displayed on the lamp. Click the [Diagnosis] button. While the diagnostic function is on, the color of the [Diagnosis] button should be green. When the [Diagnosis] button is clicked during diagnosis, the function will be suspended.

5.4.2. Diagnosis lamp The diagnostic result is displayed as follows.

● (Green): OK ● (Red): NG ● (Orange): Under diagnosis when the RCU starts up

Diagnostic items

Section The Software diagnosed on; Sensor Recording (receiving) the sentence or not. VDR CF Card, expiry date of battery, replacement date of FAN, Initial error and so on. Radar Radar image

Communication link of FGB and MCB: normal / abnormal Recording radar image: receiving the RGB signal / not receiving Quality of Radar image: judgment by service engineer

Microphone Microphone audio MIC test result: OK / NG Control of ARB by MCB: normal / abnormal Quality of microphone audio: judgment by service engineer

VHF VHF audio Quality of VHF audio: judgment by service engineer

Capsule Capsule Communication link of Capsule and RCU: normal / abnormal BER of Capsule: within the limit / beyond the limit

5.4.3. Entry lamp Error in setting entry (Model, Serial number, etc.) is warned by the “Entry” lamp.

● (Green): All entries are made. ● (Yellow): A blank remains.

Look for the blank item and input the setup data.

Page 102: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

5. SYSTEM Screen JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

96 DOC No. 7ZPNA4013D

5.5. System status window Here, the System status data of each section are displayed. The system status shows the detail information of an error.

* System status window is available at VDR, Radar, Microphone, VHF, Capsule sections. * “Sensor section” does not have the window because error information can be browsed at each detail setting

menu.

1) Selection Click a section name (e.g. Radar) positioned upper left. 2) Displaying the System status System status window of selected section appears.

Detail error information is shown in the window. To close the window, click [×] at the upper-right corner. Click the VDR section name

Page 103: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

5. SYSTEM ScreenJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

97 DOC No. 7ZPNA4013D

3) Sensor section Click [Sensor] positioned upper left of the sensor section. The recording sentence ID list appears.

Page 104: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

5. SYSTEM Screen JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

98 DOC No. 7ZPNA4013D

5.6. Operation button Click an operation button at the left of the SYSTEM screen. An operation window or an application selected is activated.

Button Operation See

Log in Press the button to return to the Log in screen 2.1.

Home Press the button to return to the HOME screen for selecting a work item 3.1

System The connection, setup, and monitoring the operation of VDR/S-VDR system are available.

4.1

Event Event log during the operation of VDR/S-VDR system appears. The list helps the maintainer to locate the fault.

6

Playback Press the button to playback and check the recorded data in Capsule or in CF card. 10

Report A report folder is created on the Desktop after completing installation. Report files are saved into this folder automatically.

13

Logout Press the button then the Maintenance software disconnects the link with RCU. The Maintenance software comes to an end.

2.2

5.7. File menu System configuration data in the Maintenance software is saved/opened by the File menu.

Page 105: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

6. EVENT MonitorJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

99 DOC No. 7ZPNA4013D

6. EVENT Monitor Monitors the operation event of VDR/S-VDR to check that VDR/S-VDR system is working correctly. The EVENT monitor can display the received EVENT data from the VDR/S-VDR. Additionally, the EVENT monitor can display EVENT Log files in the VDR/S-VDR.

6.1. Starting 1) Click the [EVENT] button on the SYSTEM screen. 2) Select the language to display the Event data

Select English or Japanese, and click [OK]. 3) Real time Event monitor Immediately after the clicking OK, the Event monitor will be turned on. Then the Event monitor displays the real time EVENT data sent from RCU. 4) RCU reboots

When the RCU is restarted by the [Reboot] button on the "SYSTEM" screen with the Event monitor turned on, the Event monitor can display the event data after starting of the RCU. Reboot the RCU for checking event data from starting of the RCU.

Page 106: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

6. EVENT Monitor JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

100 DOC No. 7ZPNA4013D

An example of Event data

Page 107: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

6. EVENT MonitorJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

101 DOC No. 7ZPNA4013D

6.2. Modification of EVENT list display

To have an access the old event data, download the event log files from the RCU. Event data from the very first operation of VDR/S-VDR are there. There are the Event log files that have been recorded on CF card by RCU.

6.2.1. EVENT log files

1) Click the [Get Event Log (CF Card)].

2) How long it will take to finish the receiving by Progress bar. 3) Older event data until the last real time monitor turning on is added to the event list.

6.2.2. Event list after last boot display The event data list can be displayed after the last boot of the RCU. Practice this function, when the older EVENT before the last boot is not needed.

1) Click the [Last boot] button. 2) The older event data before the last boot is cleared The [Last boot] button becomes blue color. 3) Click the [Last boot] colored blue. 4) Cleared old event data is displayed. (All event data display) The [Last boot] button becomes gray color again.

Page 108: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

6. EVENT Monitor JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

102 DOC No. 7ZPNA4013D

6.2.3. Extract the event data

EVENT to display can be sorted out per category. • The sorted out event data list will be displayed on another Window. • Categories are: NMEA, FGB (Radar image), Audio, Capsule, Card, System • Only one of the categories can be sorted out and displayed. 1) Click the button of the subject category name 2) The sorted out event data list is displayed on a newly opened Window. All category name buttons are now not selectable.

3) To change the EVENT category, close the present display Window of Extract EVENT.

All category name buttons return to selectable.

Page 109: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

6. EVENT MonitorJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

103 DOC No. 7ZPNA4013D

6.2.4. EVENT sort

The EVENT monitor previous sort function. 1) Click each field title. Then the sorted event list is displayed. 2) An event that plunges in during the sort is practiced is Not sorted, but is placed at the top of the list as the latest event.

6.2.5. EVENT clear All the event data in the list can be cleared. 1) Click the [Clear] button.

6.2.6. Changing Display language The language of event data list can be changed. 1) On the View menu, point to Language, and then click either English or Japanese.

Page 110: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

6. EVENT Monitor JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

104 DOC No. 7ZPNA4013D

6.3. Opening the EVENT log file

The EVENT log file recorded by the RCU and the file saved by the EVENT monitor can be opened. The files are:

• The saved event log files in the CF card • The event log files downloaded from the capsule • The event log files saved by the Event monitor

1) Opening a file Point to “Open” on the “File” menu. Then the File dialog appears. 2) Selecting a file Select “writefile.txt” on the folder where Event log is saved. 3) Displaying the event log Event log data is displayed on the event list.

6.4. Saving the EVENT log file

The following event data displayed now on the EVENT monitor can be saved as a file. • “evt” file: Recognized by “Event monitor” only.

• “csv” file type: Recognized by Excel, Notepad etc.

1) Saving a file Select “Save” or “CSV Save” on the “File” menu.

• Save: Saves “evt” file •CSV Save: Saves “csv” file

2) Selecting a save folder Select a save folder on the File dialog.

Page 111: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

6. EVENT MonitorJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

105 DOC No. 7ZPNA4013D

6.5. EVENT monitor record The received EVENT data can be recorded as a file. 1) Record start Click the [Record Start] button. Select a save folder on the File menu. The start time of recording equals the file name. Then [Record Start] changes to [Record Stop]. 2)Recording file The record file is saved on the desktop. 3)Record stop Click the [Record Stop] button. Then [Record Stop] changes to [Record Start].

Page 112: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

6. EVENT Monitor JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

106 DOC No. 7ZPNA4013D

This page left blank intentionally

Page 113: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

7. Real Time Monitor (Menu)JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

107 DOC No. 7ZPNA4013D

7. Real Time Monitor (Menu)

Although NMEA data, image data and audio data can be monitored at each Detail window in the SYSTEM screen, another real time monitor is available on the Monitor menu.

● Comparison of Real Time Monitors

Monitors Real Time Monitor on the System menu Real Time Monitor at each Detail window NMEA The monitoring of all or some channels is

supported. The monitor channel is changed easily.

Only the channel of the opened detail window is monitored.

Radar image The window size can be extended. The radar image is displayed on the wide window.

The window is fixed. The radar image is displayed on the small window.

Audio No difference Dry contact signal No difference

● Starting Each real time monitor can be started from the menu directly.

Use these real time monitors for checking the received data only apart from setups.

7.1. Starting

1) Menu Click the Monitor menu. 2) Pull down menu Point to the item to be monitored and click it (NMEA, Audio, Radar, Dry contact).

Page 114: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

7. Real Time Monitor (Menu) JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

108 DOC No. 7ZPNA4013D

7.2. NMEA monitor

Monitors the NMEA sentence data, and checks whether or not the sentence specified by the installation drawings is collected correctly.

7.2.1. Monitor conditions setup

If the specification of the laptop PC is relatively low, single channel monitoring is recommended. Incase two or more channel are monitored at a time, CPU load rises to 100%, and operation may stop. When the software freezes, press <Alt>+<Ctrl>+ <Delete> then Windows Task Manager will appear. Terminate the maintenance software there.

7.2.1.1. Selecting the monitor channel Select the CH to monitor. Click the CH to monitor from the pull down menu.

Page 115: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

7. Real Time Monitor (Menu)JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

109 DOC No. 7ZPNA4013D

7.2.1.2. Selecting the monitor data type Click the monitor mode (“RCV data”/”REC data”).

● “RCV data”: Monitors all the receiving data from the selected channel. The sentence data which is not recorded by the VDR/S-VDR is also displayed.

● “REC data”: Monitors the sentence data which is recorded by the VDR/S-VDR only.

The sentence which is not recorded is not displayed even when it is received. Monitors the data currently set in the VDR/S-VDR.

“RCV data” monitor Verify the receiving data by this in the event of receiving NG. When the wiring is reverse, unfamiliar characters will appear.

7.2.2. Monitor start and stop 1) Monitor start Click the [START] button.

The monitoring channel indicator becomes Green.

2) Monitor stop Click the [STOP] button.

The Gray light returns.

● “REC data” The addition and deletion of the CH to the monitor can be operated freely.

● “RCV data”

Capable of single channel monitoring only. In case multi channels are monitored on “RCV data”, a mixture of received data is indicated.

7.2.3. Monitor pause 1) Pause

Click the [Pause] button.

2) Restart The [Pause] button changes to the [PLAY] button during the pausing. Click the [PLAY] button to restart.

Page 116: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

7. Real Time Monitor (Menu) JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

110 DOC No. 7ZPNA4013D

7.2.4. Event clear The monitoring window can be cleared. Click the [Clear] button.

7.2.5. File save Monitor data can be saved in a file.

1) Select a saving folder

Click the [Browse] button to select the saving folder. The saving file name is invariably fixed to RtMonitor1.txt.

2) Save start

Click the [SAVE START] button. The sentence data which is monitored now is saved in the text file.

3) Save stop

The [SAVE START] button changes to the [SAVE STOP] button during the saving. Click the [SAVE STOP] button to stop saving.

7.2.6. Quit 1) Abide by the following procedure to quit monitoring. Otherwise an error arises.

Stop all of the monitoring channels. 2) Then click [Close] to quit.

Before quitting the maintenance software, please make sure that the real time monitor has been stopped. Reboot RCU, if the maintenance software has been quitted without stopping the real time monitor to stop outputting the real time data.

Page 117: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

7. Real Time Monitor (Menu)JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

111 DOC No. 7ZPNA4013D

7.3. Audio monitor Monitors the Audio data which is recorded in the ARB to make sure that the operation is practiced correctly.

Play button Stop button Volume

7.3.1. Selecting the monitor channel Click the selection button of CH to monitor.

▪ Audio1: MIC1-- MIC3 ▪ Audio2: MIC4-- MIC6 ▪ Audio3: MIC7-- MIC9 ▪ VHF: VHF1-- VHF3

Select the CH to monitor. Multiple channels cannot be played at a time. For each connected unit (MIC1,2,3,4,5,6,7,8,9, VHF1,2,3), connect only one unit to check the operation.

→ Each monitor CH receives a mixture of 3 input signals. To verify that each unit is correctly working, it is necessary to connect only one unit to the monitor.

7.3.2. Monitor start and stop 1) Monitor start

Click the [Play] button. The Audio of selected CH is outputted from the speaker. * Remember that a sound is not outputted unless the PC speaker is on.

2) Monitor stop

Click the [Stop] button to stop monitoring.

The monitored sound is played about four second later than the sound source.

7.3.3. Changing the monitor channel Keep the following procedure, when changing the monitor CH. Stop → Change monitor CH → Start

7.3.4. Quit Click the [×] button on the upper right of the window after monitor stop.

Page 118: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

7. Real Time Monitor (Menu) JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

112 DOC No. 7ZPNA4013D

7.4. Radar monitor Monitors the Radar Image which is recorded in the FGB to check the operation is working correctly.

7.4.1. Operation No need to operate since the monitor functions of itself. The image that the VDR/S-VDR is recording is displayed. The image is updated every 15 seconds as well as the image record.

The monitored image is displayed a few seconds later than the record time.

Page 119: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

7. Real Time Monitor (Menu)JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

113 DOC No. 7ZPNA4013D

7.5. Dry Contact monitor Monitors the dry contact data which is collected in the NCT-72/63, and checks whether or not the dry contact state specified by the installation drawings is correct. Be sure to check the collected data of all channels. This monitor analyzes the contents of NMEA sentence data outputted from the NCT-72/63, and the dry contact state is indicated by an icon.

7.5.1. Monitor start No need to operate since the monitor functions of itself.

The monitoring channel indicator becomes Green.

7.5.2. Monitor display In order to check the dry contact state by a monitor window, make and break the dry contact. The NMEA sentence is outputted from the NCT-72/63 according to the make or break.

Sentence sent from the NCT-72/63 ▪ When the state of a dry contact changes. ▪ Every 5 minutes and at the time power supply is turned on (all sentences).

Page 120: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

7. Real Time Monitor (Menu) JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

114 DOC No. 7ZPNA4013D

7.5.2.1. Dry contact of Alarm A dry contact state is displayed with a lamp icon.

▪ Green lamp: The state is normal. ▪ Red lamp: The state is abnormal.

7.5.2.2. Dry contact of Door The door state is displayed with an icon. ▪ : The door is open. ▪ : The door is close.

7.5.2.3. Engine Telegraph The channel that is connected to the engine telegraph is displayed with yellow lamps. Click any yellow lamp, and the window for an engine telegraph appears.

The present position is displayed by a green lamp on "Engine telegraph position", "Sub-telegraph position", and "Operating location" .

When the [Back] button is clicked, an engine telegraph window will be closed and returns to the dry contact state window.

Page 121: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

7. Real Time Monitor (Menu)JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

115 DOC No. 7ZPNA4013D

7.5.3. Clear the result of monitor The result of monitor can be cleared. Click the [Clear] button.

7.5.4. The wrong result of monitor When the monitored dry contact state is the reverse to the outputting information of the connected equipment, correct the setting of the NCT-72/63. The dry contact state (make/break) must have been set the other way.

Page 122: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

7. Real Time Monitor (Menu) JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

116 DOC No. 7ZPNA4013D

This page left blank intentionally

Page 123: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

8. System Status DisplayJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

117 DOC No. 7ZPNA4013D

8. System Status Display

The operating state of VDR/S-VDR is displayed in detail. Check the error in detail by this screen. Although the system state is displayed in each category unit in the SYSTEM screen, all items can be displayed on this System Status screen.

8.1. Starting Click the “System Status” from the “System” pull down menu.

8.2. System status display Window All lamps should be green if the VDR/S-VDR is in normal operation.

8.2.1. System Control

Page 124: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

8. System Status Display JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

118 DOC No. 7ZPNA4013D

8.2.2. Record Control

8.2.3. ROM Checksum

Page 125: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

8. System Status DisplayJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

119 DOC No. 7ZPNA4013D

8.3. Starting System status display

8.3.1. When the diagnostic function is started As the diagnostic result is already shown, no need to turn on the diagnostic function again. The [Diagnosis] button should be green.

8.3.2. When the diagnostic function is stopped When the diagnostic function has been stopped, restart the function. Click the [Diagnosis] button. The [Diagnosis] button burns green and the diagnostic result is displayed.

8.3.3. Stopping the diagnostic function Click the [Diagnosis] button during the diagnostic function is on.

The function will be stopped.

8.4. Diagnosis lamp of orange in normal operation Even if the VDR/S-VDR is operating normally, some diagnosis lamps do not become a green.

1) Capsule

The “Capsule” section of the “Record Control” window

● “Write” lamp of “Config” partition

It becomes a green lamp display only immediately after transmitting configuration data. If the RCU is rebooted, it will return to the orange display under diagnosis.

2) Microphone test

The “Audio” section of the “Record Control” window

● “Running test” lamps of “Microphone test”

A diagnostic lamp serves as an orange display under diagnosis until 12 hours pass and it carries out a microphone test, after starting. It is not necessary to check becoming a green lamp display at installation work.

Page 126: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

8. System Status Display JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

120 DOC No. 7ZPNA4013D

8.5. System status data file If the system configuration file (VdrDataInfo.dat)*1 saved at the report folder created after the completion of

installation is opened, the system state file (Status.dat) saved at the same folder can be opened automatically, and the diagnostic result at that time can be displayed.

So the diagnostic result at that time can be reproduced under offline without connecting the VDR/S-VDR. *1 The old Maintenance software (Version 1.2.0) save the system configuration file named “McbDataInfo.dat”.

Refer to Chapter 13 about the report folder.

8.5.1. Connection with the VDR/S-VDR The system status file cannot be opened while the Maintenance software is linked with the VDR/S-VDR, because the Maintenance software receives the system state data from the VDR/S-VDR. Disconnect the LAN cable.

8.5.2. File Open the system configuration file (VdrDataInfo.dat). On the “File” menu point to “Open” and click.

8.5.3. System status data display Start the System status display function. Click the [Diagnosis] button. The system state data in the selected file will be displayed.

Page 127: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

9. Functions of MenuJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

121 DOC No. 7ZPNA4013D

9. Functions of Menu

This chapter explains the auxiliary functions that can be executed from Menu.

9.1. Menu table

Regarding the function explained in another chapter as main function, the chapter and/or section number is shown in the “Refer to;” column. The arrow (►) means the function that is detailed in this chapter 9.

Menu Pull down menu Function Refer to; Open File open : System configuration file of the VDR/S-VDR or the RMS

System status file of the VDR/S-VDR or RMS Moreover, by opening the system configuration file (SysInfo.dat, VdrDataInfo.dat) saved at the report folder created after the completion of installation, the system status file (Status.dat) saved at the same folder can be opened automatically, and then the diagnostic result at the completion of installation can be reappeared. Refer to chapter 13 about the report folder.

- File

Save File save : System configuration file of VDR/S-VDR or the RMS - Control Controls the VDR/S-VDR by the Maintenance software ►

MCB Setup Edits system configuration data of the MCB Do not use this function without an instruction by JRC.

RMB Setup Edits system configuration data of the RMB Do not use this function without an instruction by JRC.

System Status Shows the system status Chapter 8 FGB setup Shows the WEB of the FGB

Do not use this function without an instruction by JRC. -

FGB Utility Adjusts the FGB Chapter 11 FGB Update Updates the program of FGB 14.2

System

HVR Shows the web of the capsule Do not use this function without an instruction by JRC.

Event Event Monitor Real time monitor of EVENT Chapter 6

NMEA Real time monitor of NMEA sentence 7.1 Audio Real time monitor of audio 7.2 Radar Real time monitor of image 7.3

Monitor

Dry Contact Real time monitor of dry contact 7.4 Convert Converts the recorded data to general file which is opened by standard

application software on PC. • NMEA data: Converts to text file • Radar image data: Converts to PNG file • Audio data: Converts to WAV file

Config Extracts a setup file from Config file saved in the CF card and the capsule

Data

Card Download Download the latest sensor data file and Radar image file recorded in CF card.

Error Code List (English) Error Code List (Japanese)

Shows meanings of Error code displayed on the OPU ►

Help

Software Version Shows the software version of Maintenance software ►

Page 128: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

9. Functions of Menu JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

122 DOC No. 7ZPNA4013D

9.2. Control The VDR/S-VDR can be controlled by the Maintenance software.

9.2.1. Starting Click the “Control” on menu.

9.2.2. Reboot system The MCB (VDR/S-VDR) and RMB (RMS) can be rebooted with remote control.

1) Click the button of the subject. ([MCB] button, [RMB] button) * This [MCB] button functions in the same way as the [Reboot] button.

Page 129: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

9. Functions of MenuJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

123 DOC No. 7ZPNA4013D

9.2.3. FGB maintenance mode

The MCB controls the FGB to record images during the VDR/S-VDR is in operation. The FGB may deny access by the maintenance software while the MCB is communicating to the FGB via Ethernet link. The FGB maintenance mode disconnects the link and makes the FGB accessible by the Maintenance software.

* Following FGB-related functions have FGB maintenance mode started automatically therefore it is not necessary

to turn on the FGB maintenance mode again. • FGB setup • FGB utility • FGB update 1) To start, click the [START] button. 2) To stop, click the [Stop] button. * Caution: Radar image can not be recorded during the FGB maintenance mode.

Be sure to stop this mode, before diving in FGB maintenance mode.

9.2.4. Initial Error Release To cancel the Initial error (Error code: 01__) is released, click the [MCB] button.

9.2.5. Real Time Clock Setup The date and time to the real time clock IC of the MCB or RMB can be confirmed and adjusted.

9.2.5.1. Display the date and time

1) Click the subject unit button. ([MCB] button or [RMB] button) The date and time of a unit selected is displayed.

9.2.5.2. Adjusting the date and time

1) Click the subject unit button. ([MCB] button, [RMB] button) The date and time of unit selected is displayed.

2) Enter the date and time. 3) Click the [Set] button. 4) Click the [Reboot] button of the target unit. (Refer to 9.2.1) 5) When the unit is rebooted, the entered date and time is set firm. Confirm the date and time after rebooting.

Page 130: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

9. Functions of Menu JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

124 DOC No. 7ZPNA4013D

9.2.6. Request Unit Mode and Function

The operation mode and function status of the MCB or the RMB can be displayed.

1) Click the unit to be checked. ([MCB] button or [RMB] button)

MODE: • Application • Safe FUNCTION: • Normal • Download

Regularly, “MODE=Application FUNCTION=Normal” should be displayed. When the update of the program ended in failure and the software freezes with the function status remaining "Download", “Request Unit Mode” shifts the status back to “Normal”.

Click the [Cancel] button.

If the [Cancel] button has no effect on shifting the function status back to “Normal” mode, there is something wrong with the equipment. Make call to service department and go into details.

Page 131: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

9. Functions of MenuJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

125

9.3. Converting the Recorded data to general files (.txt .png .wav)

The recorded data saved in the CF card or downloaded from the capsule can be converted to general files which are opened by standard application software on PC.

• Config data: Converts to text file (CSV) • NMEA data: Converts to text file • Radar image data: Converts to PNG file • Audio data: Converts to WAV file

9.3.1. Starting of the Conversion software

1) Open the "Data" pull-down menu of the System screen, and click the [Convert] button.

Source Folder Selection button Convert Folder Selection button

DOC No. 7ZPNA4013D

[Convert] button

Page 132: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

9. Functions of Menu JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

126 DOC No. 7ZPNA4013D

9.3.2. Converting to general files

1) Selecting of source folder Click the Source folder selection button, and select folders which saved recorded data.

・In order to convert downloaded data from VDR/S-VDR, select folders or files which are enclosed by the dashed line.

xxxxx¥YYYYMMDDhhmmss¥Playlist* | |―― ¥VDR | |―― ¥Init |―― ¥Log |―― ¥Audio |―― ¥Visual

・In order to convert recorded data of the CF card, select folders or files which were enclosed by the dashed line.

CF card drive |

|―― ¥Init |―― ¥Log |―― ¥Audio |―― ¥Visual

2) Converting Click the [Convert] button. Then conversion of files starts. When conversion starts, conversion status is indicated by progress bar. And converted files are indicated in the list box.

[Convert] button

Page 133: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

9. Functions of MenuJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

127 DOC No. 7ZPNA4013D

3) By drag and drop, recorded data can be converted as follows also.

In case of drag and drop, not only a converted folder, but also a file can be selected.

Drag and Drop

Page 134: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

9. Functions of Menu JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

128 DOC No. 7ZPNA4013D

9.3.3. Converted file (Industry Standard Formats files)

The Conversion software creates the converted files as follows. Data File Name Note Configuration Information

YYMMDD,hhmmss,CF,????????.csv

Digital Sensor Data YYMMDD,hhmmss,DD,????????.txt YYMMDD,hhmmss,M1,????????.wav Mix MIC-CH1, CH2 and CH3

YYMMDD,hhmmss,M2,????????.wav Mix MIC-CH4, CH5 and CH6

YYMMDD,hhmmss,M3,????????.wav Mix MIC-CH7, CH8 and CH9

Audio

YYMMDD,hhmmss,V1,????????.wav Mix VHF-CH1, Ch2 andCH3 YYMMDD,hhmmss,R1,????????.png Main Radar Image Radar Display Video

YYMMDD,hhmmss,R2,????????.png Sub Radar Image

YYMMDD: Date hhmmss: Time (UTC) ????????: IMO No. (If IMO number is not entered, automatically converts to “99999999”.)

Page 135: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

9. Functions of MenuJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

129 DOC No. 7ZPNA4013D

9.4. Config (Extract a setup file from a SysInfo.dat file)

A setup file of each unit (MCB, FGB, etc.) can be sorted out from a “SysInfo.dat” file saved in the CF card or the capsule.

9.4.1. Starting 1) Click the "Config" from the "Data" pull down menu on the system screen.

9.4.2. Selecting a Config file 1) Select a file

Click the [Open file] button, and select the “SysInfo.dat” file saved in the “Init” folder of recorded data.

9.4.3. Saving a setup file of each unit Select the unit of which setup file will be saved. 1) Selecting the unit

Click the button of the unit. 2) Saving a file Select a save folder, and input the file name.

Page 136: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

9. Functions of Menu JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

130 DOC No. 7ZPNA4013D

9.5. Downloading from CF Card(Card Download)

The latest sensor data file and Radar image file recorded in CF card can be downloaded. The software, however, does not correspond to download of an audio file.

1)Click “Card Download” by opening the pull-down menu of “Data” on System screen. 2)Select the file desired to be downloaded, and then click [Download] button. 3)Downloaded file is saved on the desktop folder.

Since the Radar image file is converted to PNG format after being downloaded, the file can be checked by opening it immediately after that.

Page 137: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

9. Functions of MenuJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

131 DOC No. 7ZPNA4013D

9.6. Error Code List

Accesses to the error code displayed on OPU and the recommended remedy.

9.6.1. Starting 1) Click the "Error Code List" from the "Help" pull down menu on the system screen.

9.6.2. Error code list The error code list is displayed.

1) Click the “ ” icon of “SYSTEM Code No.

2) Please click icon of each category.

3) Please click icon of each error code No.

The content, the cause, and the correspondence method of the error code are displayed at the right of the screen.

Page 138: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

9. Functions of Menu JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

132 DOC No. 7ZPNA4013D

9.7. Software Version display

The software version display Window appears.

9.7.1. Starting 1) Click the “Software Version” from “Help” menu.

9.7.2. Software version display window This window should appear.

Page 139: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

10. PlaybackJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

133 DOC No. 7ZPNA4013D

10. Playback

Verify that the installation and the setup have been finished successfully and the VDR/S-VDR works satisfactory by playing back the data of the capsule and the CF card.

10.1. Starting

10.1.1. Start on the SYSTEM screen Click the [Playback] button on the SYSTEM screen.

10.1.2. Start on the HOME screen When the “HOME” screen is displayed, start the Playback software with the [Playback] button of “Work” section.

1) Click the [Playback] button.

Page 140: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

10. Playback JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

134 DOC No. 7ZPNA4013D

10.2. Playback Software

The Launcher of Playback software starts. The recorded data of VDR/S-VDR are saved on the Capsule and the CF card. Do not forget to playback and check both of them. 1) Capsule The recorded data is downloaded from the Capsule to the maintenance PC via LAN. 2) CF card The recorded data is copied from the CF card to the maintenance PC with a card adaptor.

Check the recorded data of both the capsule and the CF card at the end of installation.

Playback procedure of capsule data is different from that of CF card. Playback and check the recorded data referring to the procedure mentioned in “15. Playback Software setup”.

Refer to the instruction manual of Playback software for details

10.3. Check the recorded data The recorded data shall be as follows:

• All NMEA sentences are recorded. • Radar images are recorded. • The selected radar images are recorded in two radar connection system. • Conversation in the bridge and wings is recorded • Communication of VHF transceiver is recorded

Page 141: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

11. Frame Grabber Board (CKA-137) Setup - FGB Utility -JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

135 DOC No. 7ZPNA4013D

11. Frame Grabber Board (CKA-137) Setup - FGB Utility -

“FGB_Utility” software is useful for setting up and tuning the Frame Grabber Board CKA-129/CKA-137. The setup menu has Board setup function with the aid of capture setup file and other file. The tuning menu allows maintainer to tune sync polarity, horizontal/vertical synchronization and sampling phase.

11.1. Check the Radar image specifications For proper capture setting, check the Radar image specifications (VESA format only) first then verify the following items.

Resolution: (ex. 1280x1024) Vertical synchronous signal frequency (Refresh rate): (ex. 60 Hz) Horizontal synchronous signal frequency: (ex. 75 kHz) Polarity of Vertical synchronous signal: (ex. Positive or Negative) Polarity of Horizontal synchronous signal: (ex. Positive or Negative)

11.2. Setup & Capture

11.2.1. Start the "FGB Utility" program Click the “FGB Utility” from System menu of the VDR/S-VDR Maintenance Software.

Page 142: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

11. Frame Grabber Board (CKA-137) Setup - FGB Utility - JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

136 DOC No. 7ZPNA4013D

11.2.2. Selecting the channel for tuning

a) Click the .

To tune the channel 2, click the . In case “Ch2.txt NG” message appears, align the capture setting using [Ch 2

capture setting] menu, referring to the next section. Immediately after the click, the following message appears. This message appears only on the first connection to the board.

b) Click the [OK] button.

c) "Changed to channel 1" message appears at the left bottom corner of the window.

11.2.3. Checking the captured Radar image Check the Radar image captured by FGB (CKA-137) following the instructions a) to c). a) Click [Information (I)] -> [ADC status] menu. The following message appears.

b) Click the [No] button. "ADCtxt_Analysis Function" window appears.

Page 143: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

11. Frame Grabber Board (CKA-137) Setup - FGB Utility -JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

137 DOC No. 7ZPNA4013D

c) Check that the Radar image format measured by CKA-137 is the same as that of the Rader specifications.

Resolution (estimated value): Vertical synchronous signal frequency (Refresh rate): Horizontal synchronous signal frequency: Vertical synchronous signal polarity: Horizontal synchronous signal polarity:

If the “Sync Activity” column is inactive, most probably synchronous signal could not be detected by the board. Verify the wiring, signal output and input channel.

Measured value Sync Activity ch 1 Sync Activity ch 2 V sync polarity H sync polarity V sync frequency H sync frequency: Total line number Setup value V sync polarity H sync polarity Resolution (estimated value)

Page 144: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

11. Frame Grabber Board (CKA-137) Setup - FGB Utility - JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

138 DOC No. 7ZPNA4013D

11.2.4. Set the capture setup

a) Click the [Setup(S)] -> [Ch 1 capture setting] menu.

(To practice capture setup on channel 2. Click the [Ch 2 capture setting] menu.) File selection window appears.

b) Click the "CKA137-JCY1800" folder. (If CKA-137 board is installed in JCY-1700, click the "CKA137-JCY1700" folder.)

c) Click the capture setting file. File name is formatted as shown bellow. JRC Radar setting: Cap2-"Radar model name"-1800.txt

| | | CKA-137 board installed in JCY-1800/1850

ex. JMA9900 VESA format setting: Cap2-"Resolution"-"V sync frequency"-1800.txt Resolution: 800x600, 1024x768, 1152x864, 1280x960, 1280x1024, 1600x1200 pixels V sync frequency: 60, 70, 72, 75, 85 Hz (a display of 1600x1200 resolution meets 60 Hz only.)

Page 145: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

11. Frame Grabber Board (CKA-137) Setup - FGB Utility -JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

139 DOC No. 7ZPNA4013D

d) Click the [Open] button on the file select window. The following message appears. If "Capture1.txt write NG" message appears, retry step a) to d).

e) Click the [OK] button on the message box.

11.2.5. Capturing the Radar image Capture the Radar image following the next instruction.

a) Click the icon at the top of menu.

"Finished the image capture." is displayed at the left bottom corner.

b) Click the icon.

Captured PNG image will be displayed.

Page 146: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

11. Frame Grabber Board (CKA-137) Setup - FGB Utility - JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

DOC N

11.3. Tuning

Tune the image in the following order.

1) Sync polarity tuning 2) Horizontal position tuning 3) Vertical position tuning 4) Sampling Phase tuning

11.3.1. Sync polarity tuning a) Click [Information (I)] -> [ADC status] menu.

"ADC.txt response" window appears. b) Click the [No] button.

"ADCtxt_Analysis Function" window appears. c) Check the H sync polarity.

If the measured H sync polarity is the same as that of the setup, go to the next section. If not, go to d).

140 o. 7ZPNA4013D

Measured value Setup value

Page 147: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

11. Frame Grabber Board (CKA-137) Setup - FGB Utility -JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

141 DOC No. 7ZPNA4013D

d) Click the [Tuning (T)] -> [H Sync polarity reverse]

The following message appears.

e) Click the [OK] button.

The click reverses the H sync polarity and captures the image. Then the following message appears.

f) Click the [OK] button. g) Have a look on the [ADC status] menu, and check that the measured H sync polarity is the same as that of the setup.

Regarding the V sync polarity, follow the same procedure using [V Sync polarity reverse] menu.

Page 148: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

11. Frame Grabber Board (CKA-137) Setup - FGB Utility - JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

142 DOC No. 7ZPNA4013D

11.3.2. Horizontal position tuning

If the captured image is shifted horizontally, tune the Horizontal position. If the captured image has been shifted greatly, tune by the mouse. If the shift is small go to the manual (fine) tuning.

11.3.2.1. Coarse tuning by the mouse

a) Click the [Tuning (T)] -> [Horizontal POSI. Mouse] menu. The following message appears.

b) Click the [OK] button.

Then automatic image capture starts, and the following message appears.

c) Click the [OK] button on the message box.

The message box disappears. d) Click the horizontal edge of the image. Don’t care the Y coordinates.

The following message appears.

Click the left (right) edge of the image.

Page 149: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

11. Frame Grabber Board (CKA-137) Setup - FGB Utility -JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

143 DOC No. 7ZPNA4013D

e) To practice horizontal position tuning at this point, click [Yes]. Or to retry the image shift, click [No] and tweeze

the horizontal edge of the image.

After successful horizontal position shift and image capture, the result message appears.

f) Click the [OK] button on the message box.

11.3.2.2. Manual (fine) tuning

a) Click the [Tuning (T)] -> [Horizontal POSI. manual] menu. The following message appears.

b) Click the [OK] button on the message box. After automatic image capture, the following message appears.

c) To have the image moved left, click the [Yes] button. To have the image moved right, click [No]. To finish the tuning, click the [Cancel] button.

After successful horizontal position shift and image capture, the result message appears. d) Go to step c) to have the image shifted right.

11.3.3. Vertical position tuning If the captured image is shifted vertically, practice the Vertical position tuning. If the captured image has large shift, tune by the mouse. If the shift is small, tune manually. The vertical position tuning procedure is the same as that of Horizontal position tuning. Use the [Vertical POSI. Mouse] or [Vertical POSI. Manual] menu, and refer to Horizontal position tuning procedure.

Page 150: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

11. Frame Grabber Board (CKA-137) Setup - FGB Utility - JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

144 DOC No. 7ZPNA4013D

11.3.3.1. Sampling Phase tuning

If the captured image is out of focus, tune the sampling phase to achieve the best sharpness. Normally, go to Phase AUTO tuning. A phase AUTO tuning is practiced on still image, stop the transmission of Radar.

a) Click the [Tuning (T)] -> [Phase AUTO] menu.

The following message appears.

b) Click the [OK] button on the message box.

Phase AUTO tuning start, and 35 images will be captured for tuning. During the tuning, the process is displayed on the left bottom corner. AT the end of the tuning, a result message appears.

c) Click the [No (N)] button on the message box.

Page 151: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

12. “OPTION” System SetupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

145 DOC No. 7ZPNA4013D

12. “OPTION” System Setup This chapter explains how to set up the operating environment for real-time monitor system.

MCB and RMB software Ver2.0.1 or later is capable of distributing the real-time data simultaneously by the multicast output setup as well as the conventional unicast distribution that specifies an output destination. First, check MCB and RMB software version, and then set it up as necessary.

12.1. Starting

12.1.1. Starting from “SYSTEM” Screen In order to display “OPTION” system setup screen from “SYSTEM” screen, click [HOME] button to go to “HOME” screen at first.

12.2.2. Starting from “HOME” Screen “Option PC” in “Work” section is the gate to the real-time monitor setup. Click the [Option PC] button on the “HOME” screen.

Page 152: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

12. “OPTION” System Setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

146 DOC No. 7ZPNA4013D

12.2. Setup Procedure

1) To receive a setup data, click the [Receive] button. 2) To input the setup data, select the output data to the real-time monitor. 3) To set up IP address of RCU and Option PC, click the [Edit] button. 4) To transmit the setup data, click the [Set] button.

The setup operation of multicast is the same as that of the conventional real-time monitor except entering the IP address for simultaneous distribution.

12.3. Registration Information Registration information entered on Log-in screen is displayed first. Then registration stored in the RCU is displayed when the configuration data is received. After setting up, the registration data is updated with the new data entered on the "Log in" screen.

12.4. IP Address 12.4.1. For Real Time Monitor

The VDR/S-VDR outputs the real time data to the specified IP address. To change the IP address, open a Network window by clicking the [Edit] button. 1) VDR-WAN port

Designate the IP address of VDR-WAN port on RCU which is connected to the option PC.

Default: 192.168.0.254 2) Option PC Designate the IP address of the monitor PC. Default: 192.168.0.251

Page 153: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

12. “OPTION” System SetupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

147 DOC No. 7ZPNA4013D

3) When distributing real-time data via router:

In order to distribute real-time data via router to the computer in the different network from the network to which VDR is connected, check the checkbox of "Router" on the Option PC main screen. Click the [Edit] button to display the setup screen. Enter router IP address in the “Next Hop” field, and then click the [Set] button.

Default: 192.168.0.253

12.4.2. For Multicast VDR/S-VDR is capable of distributing data simultaneously by an assigned multicast address. When modifying the multicast address, click the [Edit] button to display the setup screen. 1) EXT LAN Check the checkbox of “EXT LAN”.

2)Address Enter a multicast address. Default: 239.0.112.1

3)Port Enter a port number. Default: 6501

Reception side should also set up the same multicast address and port number as what was set up above.

12.5. “Real Time Monitor” Section Check the subject data of real time monitor.

Page 154: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

12. “OPTION” System Setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

148 DOC No. 7ZPNA4013D

Normally, as all the data are required by the real-time monitor, all the boxes of connected channels are checked as default.

1) Sensor section

Only the connected CH can be set up. Do not setup the channels of unchecked boxes. Check each channel that should output a NMEA data. The NMEA sentence data are outputted from the checked channels.

2) Audio Check “AUDIO” box for outputting an audio monitor data.

3) FGB1 Check “FGB1” box for outputting an image monitor data from the VDR/S-VDR.

4) FGB2 The current maintenance software does not support the setup.

Do not check the checkbox. 5) All Enable button

When the [Enable] button is clicked, all monitor channels will be activated. With the click, all the channel boxes are checked.

6) All Disable button

When the [Disable] button is clicked, all monitor channels will be deselected. With the click, all the channel boxes are undone.

Multicast output can distribute sensor data only. Check the checkbox of the CH to be output.

Page 155: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

13. ReportJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

149 DOC No. 7ZPNA4013D

13. Report

When the installation is completed, create a set of report files using this function.

13.1. Starting

1) Click the [Report] button on the SYSTEM screen. “Report” screen will appear.

Page 156: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

13. Report JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

150 DOC No. 7ZPNA4013D

13.1.1. Report Setup data, diagnosis, check result and so on can be confirmed in the Report screen. And all the contents are saved to files as service report. Since the Report files are registered in the Ship List of the Marine Service Department Home Page, send the files to

the Marine Service E-mail address with the following subject. Subject : JCY-1800 Report (or JCY-1850 Report) E-mail :[email protected]

13.1.2 Report screen

Page 157: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

13. ReportJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

151 DOC No. 7ZPNA4013D

13.1.3 Composition of Report screen

No. Item Contents Check Diagnosis Entry Contents

Comment

Unit Info

1 Ship’s Information

Ship’s Information □

2 VDR Information

VDR register information □

3 Installation Checking of Installation □ □ ■

4 Sensor Checking of setup and operation ● ● ■ ● 5 NSK

(CH33,34) Checking of setup and operation ● ● ● ■ ●

6 A/D Checking of setup and operation □ ● ■ ● 7 VDR Checking of setup and operation □ ● ● ● ■ 8 Radar Checking of setup and operation □ ● ● ● ■ ● 9 Microphone Checking of setup and operation □ ● ● ■ ● 10 VHF Checking of setup and operation □ ● ■ ● 11 Capsule Checking of capsule operation □ ● ● ■ ● 12 Blackout Checking of blackout test □ ■ 13 Playback Checking of Playback software □ ■ 14 Event Checking of Event Monitor □ ■ 15 Option PC Amendment resister information ● 16 RMS Amendment register information ●

1) Check : Quality judgment of operation by serviceman 2) Diagnosis : Lamp indication by Diagnosis 3) Entry : Lamp indication by Entry check 4) Contents : Registered contents in VDR with Maintenance software 5) Comment : Comment to judgment of Diagnosis or Entry check 6) Other : Detail of connected unit

Report screen is composed by 16 tab screens as shown with above table. ● : Automatic input item (Registered contents with Maintenance software)

□ : Input items in the Report screen ■ : Comment input item

Page 158: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

13. Report JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

152 DOC No. 7ZPNA4013D

13.1.4 Search Function

There are 4 buttons for searching item of NG judgment or no entry in the Report screen. A deficient report which is not can be created by using these functions.

No. Search selection Search

target Search condition Measure

1 No entry lamp Entry

When Entry lamp is: • NG lamp • No-entry lamp

Return the setup screen by the [System] button. And input item which is not inputted.

2 NG lamp of Diagnosis Diagnosis

When Diagnosis lamp is: • NG lamp 【Note】It is excepted during diagnosis.

Return the setup screen by the [System] button. And check the cause and cancel error.

3 No entry of Contents Contents • Incase of no entry Input so that there is no blank. 4 NG result of Check Check • In case of no-selection

• Incase of NG 【Note】No-comment is excepted.

• In case of no-selection, select OK or NG.

• In case of NG, input error cause in comment box.

Operation

1) Select any one from 4 Search selections in the Tab Selection. 2) Tab select button which is searched blinks red. 3) Click the tab select button which blinks red.

Tab screen can be selected by click tab directly also. 4) Searched item is indicated by red.

In order to cancel error, measure in accordance with above table.

Page 159: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

13. ReportJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

153 DOC No. 7ZPNA4013D

13.1.5 Save report file

When the [Save] button is clicked, report folder is created instantly as RCU serial number (MBxxxxxx)_VDR_report on the desktop screen. Moreover setup files the other than a report files are saved as service report instantly into the report folder. Compress the report folder, and send it to the Marine Service E-mail address with the following subject. The Report files are registered in the Ship List of the Marine Service Department Home Page

Subject : JCY-1800 Report (or JCY-1850 Report) E-mail :[email protected]

Saved files: • Report file • MCB system configuration file • RMB system configuration file *1 • MCB system status file • RMB system status file *1 • FGB setup file *1 • DSC setup file *1 • Event log file • Radar image file *1 • Sensor data file

*1: In case of non-connection, the files are not saved.

Save the report file by [Save] button. If necessary, the report file can be renamed and saved.

If the report is saved, save folder, file name and creation date is indicated.

Save folder and file name Creation date

Page 160: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

13. Report JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

154 DOC No. 7ZPNA4013D

13.1.6 Open report file

Click the [Open] button, and select report folder in the Open screen, select a report file. Contents of selected report file are indicated. If necessary, the opened report file can be and corrected. Because diagnosis is started automatically in the report screen, latest Diagnosis results are updated into the opened

report file.

Select a saved report file, click the [Open] button.

Save folder, file name and creation date of opened file are indicated.

Save folder and file name Creation date

Page 161: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

14. Program updateJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

155 DOC No. 7ZPNA4013D

14. Program Update Update the program of MCB, ARB RMB and FGB in the RCU according to the following instructions.

14.1. Program update of MCB, ARB and RMB Update the program of MCB (CDJ-2304), ARB (CHA-387) and RMB (CDK-287) as follows.

14.1.1. Update application The application for update starts from the HOME screen. Select the [RCU Update] button from the work section.

1) Click the [RCU Update] button.

Page 162: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

14. Program update JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

156 DOC No. 7ZPNA4013D

14.1.2. Select an update program (1. Program)

1) Select a program Select an update program with the program radio button. 2) Version check Check the version of the present program. Click the [Version] button and the present version is shown. If it is the latest, program update is not needed.

14.1.3. Load a Program file (2. Program File) Load the update program file. Click the [Browse] button, and select the update program file.

14.1.4. Check IP address and Port number (3. Port) Verify that they are as follows.

• MCB, ARB: 192.168.110.3 6000 • RMB: 192.168.60.3 6000

14.1.5. Update start (4. Update) Start to update the program. Click the [Update] button.

State of upload is displayed by progress bar and the message.

14.1.6. Update complete 1) Confirm that the update is completed. • Check that progress bar is complete till the end. • Check that [END] Update Success” is displayed in the progress message

The RCU is restarted automatically and operated with the renewed program after the updating has been completed. It is not necessary to reconfigure the system following the update.

2) Check the version of the updated program. Click the [Version] button and the version will appear. 3) Quit the update application.

Page 163: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

14. Program updateJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

157 DOC No. 7ZPNA4013D

14.2. Program update of FGB Update the program of FGB (CKA-137) according to the following instructions.

14.2.1. Preparation for FGB update The application for update starts from the “System” menu on the “System” screen. When the "Home" screen is displayed, click the [Installation] button to move to the "System" screen.

1) FGB WEB screen Click the [FGB Setup] from the “System” menu on the “System” screen. Internet Explorer (IE) starts and the root menu of the FGB WEB screen is displayed. 2) Put the FGB in SLEEP mode as a preparation for program update. Click the [Sleep] button on the root menu. Confirm that “OK” message appears.

Page 164: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

14. Program update JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

158 DOC No. 7ZPNA4013D

3)Return to the root menu Click the [Back] button of IE, and the display screen will go back to the root menu. * Do not click the [renew] button.

14.2.2. Starting the FGB Update application Start the FGB update application. Click the [FGB Update] button from the “System” menu on the “System” screen.

14.2.3. Program file

Select a program file for update. Click the [Browse] button, and select the program file for update.

14.2.4. Check a IP address and Port number Verify that they are as follows.

・ FGB: 192.168.110.151 80

14.2.5. Update start Start to update the program. Click the [Execute] button.

State of upload is displayed by progress bar and a message.

14.2.6. Update complete 1) Confirm that the update is completetd.1 • Check that “Application write OK” is displayed in the message window. 2) Quit the update application. 2) Reboot the RCU by turning off and on the AC power. 3) Click the [renew] button on the FGB WEB root menu of the IE.

Check the updated program version.

Page 165: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

14. Program updateJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

159 DOC No. 7ZPNA4013D

14.3. Program update of Capsule Update the program in Capsule (NDH/316/316A, NDH-317/317A) according to the following instructions.

14.3.1. Starting the capsule update application Start the capsule update application from Home screen. Confirm the capsule model connected to VDR/S-VDR. For VDR, click the [NDH-316 Update] button or the

[NDH-316A Update] button from “Work” section. For S-VDR, click the [NDH-317 Update] button or the [NDH-317A Update] button.

1) Click a corresponding to update button according to the capsule in use.

2) Update software version saved in the maintenance software is displayed on the “Capsule Update"dialog. If the version is out of date, select the latest version by clicking the [Browse] button. After the select update software version is displayed, click the [Yes] button to proceed.

Note)

The Open dialog displays by clicking the [Browse] button. Select the folder where the latest update software is saved, and then

update the capsule. Capsule update software file name ・xVR02 type: ram_XVR02_x-xx-xxx.bin ・xVR03 type: ram_XVR03_x-xx-xxx.bin

Software Version

Page 166: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

14. Program update JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

160 DOC No. 7ZPNA4013D

3) The following update screen displays

4) Confirm current software version by clicking the [Get Current SW Version] button.

5) Input a “✓” mark beside “Automatic Reboot after update”, and then start update process by clicking [Update

Software] button.

6) Updating status is indicated in the Status bar.

When the update is completed, confirm the software version by clicking the [Get Current SW Version] button.

7) Click the [Exit] button to close the update screen.

“✓”

Software version

Updating status

Page 167: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

15. Playback Software SetupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

161 DOC No. 7ZPNA4013D

15. Playback Software Setup

15.1. How to play back the downloaded data from the Capsule via Ethernet

The flow from Setup to Playback is shown below. ① Stop recording to capsule.

② Download data from capsule by the Download software.

③ Set information required for playback with the Setup software.

④ Start the Playback software.

15.1.1. Downloading data from the Capsule by Download software ① Click the [DOWNLOAD] button on the “VDR INVESTGATIVE SOFTWARE” launcher menu, and start the

Download software.

② Download screen is displayed

[DOWNLOAD] button

Page 168: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

15. Playback Software Setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

162 DOC No. 7ZPNA4013D

③ Select a save place with the aid of Folder selection button, and then select a playlist. Once download starts, playlists (from playlist1 to playlist10) are created automatically under the save place. Saving maximum 9 download data is possible under the playlist folder except playlist1.

④ Set download value with the slide bar.

Note) Download data size can be specified in every 1 % with slide bar.

⑤ Check the box of necessary download data and click the [Start] button.

Please press [OK] button, click [Cancel] button of the download software, and end the download software.

⑥ When download starts, each download status is indicated by progress bar.

Folder Selection button

Playlist

Page 169: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

15. Playback Software SetupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

163

⑦ When the following screen appears, download is completed.

Click the [OK] button, and close the Download software with the [Cancel] button.

DownloadDownload

Download was completed.

OK

15.1.2. Set information required for playback with Setup software ① Click the [PLAYBACK] button on the “VDR INVESTIGATIVE SOFTWARE” launcher menu.

② Click the [SETUP] button on the “PLAYBACK” launcher menu, and start the Setup software.

【Note】Folder Composition Save Place (Save Folder)

Save Folder(Created by the folder name registered on the input screen ((5) section).) Playlist1 Playlist2 VDR Init Log Audio Visual Event Playlist3

Playlist10

[SETUP] button

[PLAYBACK] button

DOC No. 7ZPNA4013D

Page 170: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

15. Playback Software Setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

164 DOC No. 7ZPNA4013D

③ The Login screen appears. Click the [OK] button after confirming that “User” has been clicked in the Operator

block.

④ To import VDR/S-VDR configuration data, select the following file in the download data and click the [Import] button.

*: ¥Playlist2¥VDR¥Init¥SysInfo.dat

⑤ Click the [Folder Selection] button, and select the folder created in accordance with the “3.1.3 Download data

from VDR/S-VDR by Download software”.

⑥ Click the [Set] button, and the setup is completed.

To close the Setup software, click the [Close] button.

Download folder

User

Page 171: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

15. Playback Software SetupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

165 DOC No. 7ZPNA4013D

15.1.3. Start the Playback Software

1) Click the [PLAYBACK] button on the “VDR INVESTIGATIVE SOFTWARE” launcher menu.

2) Click the [PPLAYBACK] button on the “PLAYBACK” launcher menu, and start the Playback software.

3) Playback screen is displayed.

[PLAYBACK] button

[PLAYBACK] button

Page 172: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

15. Playback Software Setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

166 DOC No. 7ZPNA4013D

4) Select playback time by the Slide bar.

Slide bar Playback button Slide bar select button Playback time span of the Slide bar can be selected by the Slide bar select button.

・12hours: 12 hours ・All: All the periods of record data

【Note】 In case of downloading from the Capsule, the record data period might be for a few days. Playback time span of the Slide bar becomes long, and so it is not easy to adjust playback time. In that case, select the 12 hours in the Slide bar select button. Playback time span becomes 12 hours; moreover, scale in every hour is displayed. So it is easy to adjust playback time.

5) Click the [Playback] button to start playback.

Page 173: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

15. Playback Software SetupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

167 DOC No. 7ZPNA4013D

15.2. How to play back the CF card data

In order to play back record data of CF card, it is necessary to create a playback folder in the computer of in advance, and to copy the data.

The flow from Setup to Playback is shown below.

① Create a playback folder at My Computer before Setup.

② Set required information for playback with Setup software.

③ Start the Playback software, and copy the record data of CF card.

15.2.1. Create a playback folder 1) To create a playback folder, start My Computer. 2) Create a folder as follows.

Playback data is copied to the folder made here. C:¥MV JRC

↑ E.g. Ship’s name

15.2.2. Set required information for playback with the Setup software 1) Click the [PLAYBACK] button on the “VDR INVESTIGATIVE SOFTWARE” launcher menu.

2) Click the [SETIP] button on the “PLAYBACK” launcher menu, and start the Setup software.

[PLAYBACK] button

[SETUP] button

Page 174: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

15. Playback Software Setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

168 DOC No. 7ZPNA4013D

3) As the Login screen appears, click the [OK] button after confirming that “User” has been clicked in the Operator

block.

4) Eject a CF card from the VDR/S-VDR, and insert to the card slot of another laptop PC. Then, to import VDR/S-VDR configuration data, select the following file in the CF card and click the [Import] button. Note: Which drive is for CF card depends on the PC model.

D: ¥Init¥SysInfo.dat

5) Click the [Folder Selection] button, and select a folder created in accordance with the “3.1 Create a playback folder”.

6) Click the [Set] button to finish the setup. To close the Setup software, click the [Close] button.

CF card drive as an example

User

Page 175: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

15. Playback Software SetupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

169 DOC No. 7ZPNA4013D

15.2.3. Copy a record data of CF card 1) Click the [PLAYBACK] button on the “VDR INVESTIGATIVE SOFTWARE” launcher menu.

2) Click the [PLAYBACK] button on the PLAYBACK launcher menu., start the Playback software

3) Playback screen is displayed.

[PLAYBACK] button

[PLAYBACK] button

Page 176: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

15. Playback Software Setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

170 DOC No. 7ZPNA4013D

4) Click the [Playlist] button on the Playback Operation Panel.

Playback button Playlist button

5) Verify whether or not the CF card drive is set in the Copy source. If not, click the [Folder Select] button to select the drive.

6) Select a playlist in the Copy place and copying data volume in the Size and then click the [Copy] button.

Copying volume can be selected from 1hour to 12 hours or all. If 1hour is selected, 1 hour data from the latest is copied.

7) Check playlist2-Playlist10 where CF card data have been copied, then click the [OK] button.

8) Click the [Playback] button on the playback panel to start playback.

Page 177: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

15. Playback Software SetupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

171 DOC No. 7ZPNA4013D

15.3. How to quit the Playback software

1) Click the [Setup] button located at the bottom right in the playback screen and the Setup screen appears.

2) Click the [Exit] button located bottom left in the Setup screen.

[Setup] button

[Exit] button

Page 178: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

15. Playback Software Setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

172 DOC No. 7ZPNA4013D

This page left blank intentionally

Page 179: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

16. Remote Maintenance System SetupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

173 DOC No. 7ZPNA4013D

16. Remote Maintenance System Setup To activate the Remote Maintenance System, set up this section as following procedure.

16.1. Log in

16.1.1. Log in to the RMS after setting up the VDR or S-VDR Login again to Remote Maintenance System (RMS). . 1) Return to the Log in screen. Click the [Login]on the left side of screen. 2) Log in to the RMS Select the RMS, and then click the [Next] button. The HOME screen of RMS appears.

16.1.2. Log in to the RMS first 1) Log in to the RMS Select the RMS, and then click the [Next] button. The HOME screen of RMS appears. 2) Select the subject equipment (VDR or S-VDR).

* When the S-VDR is connected to the Inmarsat (Fleet), S-VDR will be maintained with the RMS.

The HOME screen of RMS appears

Page 180: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

16. Remote Maintenance System Setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

174 DOC No. 7ZPNA4013D

16.2. HOME screen

Click the [Installation] button, and then the System screen for setup appears.

16.3. System screen

1) VDR system screen Check box for RMS connection

Page 181: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

16. Remote Maintenance System SetupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

175 DOC No. 7ZPNA4013D

2) S-VDR system screen (Built-in RMB)

Check box for RMB connection

Page 182: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

16. Remote Maintenance System Setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

176 DOC No. 7ZPNA4013D

16.3.1. Basic setting up procedure

The basic remote maintenance function can be set up by the following procedure. Only VDR and S-VDR with built-in RMB can collect and preserve the maintenance data from JRC equipment. The S-VDR without built-in RMB can only diagnose itself by the remote access connection.

1) Receiving configuration data

Click the [Receive] button to receive configuration data. The connection setup screen of VDR/S-VDR displays.

2) Connection setup of the JRC equipment connected to VDR (For VDR/S-VDR with built-in RMB only)

Check the checkbox of RMS connection channels. Usually, setup is completed only by checking.

3) Connection setup of the JRC equipment newly connected for RMS (For VDR/S-VDR with built-in RMB only)

Check the checkbox of channels to additionally register the connection setup of the JRC equipment connected for RMS.

Click the [Detail] button, and then the detail setup window appears. Enter the identification data and interface data of connecting equipment like setup for VDR. The sentence ID of maintenance sentence (PJRC) is inputted automatically.

4) Setting up the IP address (to VDR and S-VDR) Set up the IP address of VDR and Inmarsat (Fleet).

16.3.2. Detailed setup for serial connection Click the [Detail] button after selecting a subject serial channel, and then the detail setup window appears.

1) Identification screen

Set up identification data of connected equipment.

Page 183: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

16. Remote Maintenance System SetupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

177 DOC No. 7ZPNA4013D

• Equipment which is set up for VDR connecting Setup is completed already, so setup data cannot be modified. • Equipment which is set up for RMS connecting newly Set up identification data of equipment. • Comment Enter helpful information for maintaining. The entry of a comment is not mandatory.

Enter the identification data and interface data of connecting equipment like setup for VDR. The sentence ID of maintenance sentence (PJRC) is inputted automatically.

2) Data screen

Set up serial interface and sentence ID of maintenance sentence.

• Equipment which is set up for VDR connecting Setup is completed already, so setup data cannot be modified. • Equipment which is set up for RMS connecting newly Default data is inputted automatically. Modify the default data which is not adapted to connected equipment.

• Sentence ID for maintenance “PJRC” is inputted automatically for Remote Maintenance. Some equipment may require another sentence ID. If sentence ID have to be changed, setup information will be released by the Marine service WEB. • Max interval (RMS)

Set the maximum time interval of receiving. If the time taken to receive a data sentence exceeds this limit, the sentence is denied and an error arises. Set a longer time when an error arises.

Page 184: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

16. Remote Maintenance System Setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

178 DOC No. 7ZPNA4013D

16.3.3. Detailed setup for LAN connection This setup is required when equipment which output a maintenance sentence via LAN is connected. At present (Feb. 2007), the equipment connected by LAN is only VDR.

1) Identification screen

This screen is same as screen for serial connection. 2) Data screen

Set up the LAN interface.

• IP address Set up the IP address of equipment which output a maintenance sentence. (IP address: 192.168.60.xxx)

IP address table

• Sentence ID for maintenance “PJRC” is inputted automatically for Remote Maintenance. This ID cannot be modified.

• Max interval (RMS)

Set the maximum time interval of receiving. If the time taken to receive a data sentence exceeds this limit, the sentence is denied and an error arises. Set a longer time when an error arises.

Page 185: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

16. Remote Maintenance System SetupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

179 DOC No. 7ZPNA4013D

16.3.4. Network setup for RMS

Set up the IP address for connecting VDR to Inmarsat (Fleet). 1) Verify the IP address

The IP address set up is displayed. Click the [Edit] button in order to test a link of LAN, then the window for Network setup appears.

•VDR: 192.168.0.254 •INM: 192.168.0.1 2) Link test

Click the [Start] button, and then the lamp lights in green or red as a result of test. ● (Green): Result of test is good. ● (Red): Result of test is not good.

3) Modifying the IP address

Modify the IP address of VDR and Inmarsat (Fleet) when the IP address set up cannot be adapted to the Network. Test the link of LAN after modifying the IP address.

16.3.5. Starting the diagnosis function The OK/NG of receiving maintenance data are indicated by the color of “Diagnosis” lamps. The meaning of each color is:

● (Green): OK ● (Red): NG ● (Orange): The system is under diagnosis 1) Click the [Diagnosis] button. 2) Confirm that the color of [Diagnosis] button changed to green.

If the [Diagnosis] button is clicked during the diagnosis function is on, the function will be stopped.

Page 186: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

16. Remote Maintenance System Setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

180 DOC No. 7ZPNA4013D

16.3.6. Downloading and viewing RMS data

This section introduces the remote maintenance data download and viewer screens. For detailed instruction, refer to Remote Maintenance Installation Manual of separate volume.

16.3.6.1. Starting “RMS Viewer”

Click [RMS Viewer] button.

Page 187: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

16. Remote Maintenance System SetupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

181 DOC No. 7ZPNA4013D

16.3.6.2. Main screen 1)Connected equipment information 2)Reception lamp 3)Alarm lamp 4)Selecting download data 5)[Download] button

6)Viewer screen start button Latest data Log data Received data

1)Connected equipment information

When RMS main screen is in communication (when it is opened), it acquires system configuration information from RMS and displays it. It displays the equipment connected for RMS, not for the exclusive use of VDR.

2)Reception lamp

When PJRC sentence (maintenance data) is being received in specified interval time, the Reception lamp indicates green. If not, it indicates red.

3)Alarm lamp When the relevant equipment is operating normally, the Alarm lamp indicates green. If it is generating the error, the lamp indicates red. → Acquire (Download) maintenance data of the equipment with error indication, and then analyze the root cause. * Speed Log(JLN-205/550): The Alarm lamp always shows in orange since it utilizes special sentence.

Page 188: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

16. Remote Maintenance System Setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

182 DOC No. 7ZPNA4013D

4)Selecting download data

Checkboxes for the following data in each CH are provided. Check the only checkbox of necessary maintenance data, and then download it.

・Latest data(Target sentence: PJRCL/PJRCM/PJRCD) The latest data of each maintenance sentence are recorded. ・Log data (Target sentence: PJRCL) The log data is recorded only if the change occurs in the content of receiving sentence data.

Download it by specifying the download size (0-100%) in relation to all storage capacity of recorded data.

・Received data(Target sentence: PJRCL/PJRCM/PJRCD) All received maintenance sentence data are recorded.

Download it by specifying the download size (0-100%) in relation to all storage capacity of recorded data.

5)[Download] button The download of specified maintenance data starts by clicking the [Download] button. Downloaded data can be saved as a file and displayed.

6)Viewer screen start button The viewer screen of downloaded data can start up by clicking viewer screen start button after the data downloading.

16.3.6.3. Selecting download data

1)Individual selection Click to check each checkbox of maintenance data that you desire to download. When downloading multiple data at the same time, check all checkboxes of the data concerned.

2)Package selection

When downloading all maintenance data, all checkboxes can be checked together at the same time. ・ Select “All Check” from “View” menu. ・ As the following checkboxes display in the right side of screen, check the checkbox of necessary data

classification.

・ Checkboxes of all pieces of equipment are checked.

3)Download

Click the [Download] button to start downloading the maintenance data.

Page 189: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

16. Remote Maintenance System SetupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

183 DOC No. 7ZPNA4013D

16.3.6.4. Viewing downloaded data

1)Selecting target equipment Click the [CH**] button of target equipment to display the maintenance data viewer window.

2)Selecting conversion table ・Click the [Data Form] button to display the file selection dialog. ・As conversion file list displays, select a conversion file for the equipment concerned from the list.

3)Selecting the maintenance data to be viewed Select the maintenance data classification from menu bar.

・ Latest : Latest data ・ Log(Diff) : Log data ・ Log(All) : Received data

Page 190: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

16. Remote Maintenance System Setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

184 DOC No. 7ZPNA4013D

16.3.6.5. Latest (Latest data)

The latest data of each sentence (identified by the sentence number) can be displayed. Each sentence is converted to text first, and then displayed.

● Data status (OK: Green lamp, NG: Red lamp) ● Received date & time (UTC) & ship’s position at the time of reception (Lat / Lon) ● Converted data display (Code→Text) ● Text data display (displays received data)

Page 191: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

16. Remote Maintenance System SetupJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

16.3.6.6. Log (Dif) (Log data)

The recorded maintenance data displays only if the change occurs in the content of receiving maintenance data sentence. Selected sentence is converted to text first, and then displayed.

● Received date & time(UTC) ● Ship’s position at the time of reception (Lat / Lon)

New

185 DOC No. 7ZPNA4013D

● Status データ → ランプ表示 (NG:赤ランプ 表示を含むセンテンスを赤色表示) 本画面のログでは MSG. No.15 が「異常→正常→異常」と変化しているのが判る。

● Selected sentence for conversion

Old

Page 192: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

16. Remote Maintenance System Setup JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

186 DOC No. 7ZPNA4013D

16.3.6.7. Log (All) (Received data)

All received and recorded maintenance data are displayed. Selected sentence is converted to text first, and then displayed.

● Selected sentence for conversion

Page 193: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

17. InstallationJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

187 DOC No. 7ZPNA4013D

17. Installation Here the installation procedure of the maintenance software for JCY-1800 / 1850 is described.

17.1. Uninstall the old version

If the old version has already been installed, make the old version by way of the “Control Panel” – “Add/remove Programs” of Windows.

17.2. Installation procedure

Download the latest version from the Marine Service WEB.

for Windows Vista ・When you install the maintenance software, you should log into your PC by administrator account and execute it.

In that case, execute by the "Allow" of the confirmation screen. ・When the Setup.exe is clicked , the confirmation screen is displayed. Select the "Allow" and start installation.

Allow

Page 194: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

17. Installation JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

188 DOC No. 7ZPNA4013D

1) Perform “setup.exe”

Double-click the”setup.exe” file.

2) Start installer When the [Next >] button appears, click it after displaying the following window.

3) Input the user information Input “jrcvdr” into the serial number block and click the [Next >] button.

Page 195: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

17. InstallationJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

189 DOC No. 7ZPNA4013D

4) Installation folder

As default, “Program Files¥JRC¥JCY1800¥Maintenance” is specified as the installation folder. Click the [Next >] button.

5) Start installation Click the [Install] button to start the installation.

6) Click the [Finish] button. The installation of the maintenance software is completed.

Page 196: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

17. Installation JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

190 DOC No. 7ZPNA4013D

7) The installer of Tera Term starts continuously.

Tera Term Hyper Terminal has been discontinued in Windows Vista. When the VDR IF (router) of VDR real time monitor is set up, Use the Tera Term instead of Hyper Terminal.

8) Click the [Next>] button.

9) Select "I accept the agreement", and click the [Next>] button.

10) Click the [Next>] button.

Page 197: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

17. InstallationJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

191 DOC No. 7ZPNA4013D

11) Select the "English", and click the [Next>] button.

12) Click the [Next>] button.

13) Click the [Next>] button.

14) Click the [Install] button.

Page 198: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

17. Installation JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

192 DOC No. 7ZPNA4013D

15) Click [Finish] button.

16) Installation of the Tera Term is completed The icons of the JCY-1800 Maintenance software and the Tera Term software are created on the desktop.

Page 199: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

17. InstallationJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

193 DOC No. 7ZPNA4013D

17)When Windows Vista PC is used, it is necessary to continue and to cancel UAC (user account control).

Cancel it according to the following operations.

・Right-click in the “JCY-1800 Maintenance" icon on the desktop.

・Select Properties.

・Select the Compatibility tab.

Properties

Compatibility tab

Page 200: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

17. Installation JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

194 DOC No. 7ZPNA4013D

・Input a "✓" mark in "Run this program as an administrator" of "Privileged level", and click the [OK] button.

The setup for the Windows Vista is completed.

For Windows Vista

When you use the maintenance software, you should log into your PC by administrator account and execute it. In that case, execute by the "Allow" of the confirmation screen.

Privileged level

Allow

Page 201: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

17. InstallationJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

195 DOC No. 7ZPNA4013D

17.3. Language setting of maintenance PC If the operating system (OS) on your PC is not Japanese or English version, Maintenance software might not works correctly. Please set language to the "English (United States)” or the “English (United Kingdom) “as follows.

●For Windows XP

1) Click the "Date, Time, Language, and Regional Options" on the Control Panel screen.

2)Click the “Regional and Language Options”.

Clock, Language, and Region

Clock, Language, and Region

Page 202: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

17. Installation JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

196 DOC No. 7ZPNA4013D

3)Select the "Regional Options" tab, select the "English (United States)" or the "English (United Kingdom)".

4) Select the "Advanced" tab. Select the "English (United States)" or the "English (United Kingdom)", and then click the [OK] button. You will be asked to restart Windows, and then restart it.

Regional Options tab

English (United States) or English (United Kingdom)

Advance tab

English (United States) or English (United Kingdom)

Page 203: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

17. InstallationJCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

197 DOC No. 7ZPNA4013D

●For Windows Vista

1) Click the “Clock, Language, and Region” on Control Panel screen.

2) Click the "Regional and Language Options".

Clock, Language, and Region

Regional and Language Options

Page 204: JRC-JCY 1800-1850 MAINTENANCE SOFTWARE INSTRUCTION MANUAL

17. Installation JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual

198 DOC No. 7ZPNA4013D

3) Select the "Formats" tab, select the "English(United States)" or the "English(United Kingdom)",

4) Select "Administrator" tab. Click the [Change system locale] button, and select the "English (United States)" or the "English (United Kingdom)”, and then click the [OK] button.

You will be asked to restart Windows, and then restart it.

Administrator tab

Format tab

English (United States) or English (United Kingdom)

[Change system locale] button