Control Dampers
and Fire Dampers
Insulated Control Dampers
Non-Insulated Control Dampers
Framing
Jack Shaft
Accessories
Steel Control Dampers
Fire Dampers
Volume 1 - March 2010
Job Photo:University ofSherbrooke
Hospital CenterEmergency Standby
GeneratorSherbrooke, Quebec.
Alumavent’s 3900 Seriesis a premium low leakage insulated control
damper and features the lowest air leakage
rating available.The damper’s thermally
broken blade was developed to reduce the
thermal transfer of heat from one side of
the damper to the other. It minimizes con-
densation on the cold side of the damper
and helps prevent damper from freezing
closed. The thermally broken blade and
extremely low leakage performance of the
3900 greatly reduces the amount of thermal
transfer, significantly increases system effi-
ciencies, and offers increased energy savings.
All of these factors are important to con-
sider with today’s Green building practices.
3900 Insulated Control Dampers
2 Tel.: (905) 857-4700 • Fax: (905) 857-4730 • Toll Free: 1-800-668-7214 • www.ventexinc.com
SuperiorAir Leakage
Performance
SuperiorAir Leakage
Performance
SuperiorAir Leakage
Performance
SuperiorAir Leakage
Performance
SuperiorAir Leakage
Performance
AMCA Certified RatingsAlumavent Inc. certifies that the 3900 SeriesInsulated Parallel Blade Control Dampersshown here are licensed to bear the AMCASeal. The ratings shown are based on testsand procedures performed in accordancewith AMCA Publication 511 and complywith the requirements of the AMCACertified Ratings Program. The AMCACertified Ratings Seal applies to air per-formance ratings and air leakage ratings.
LEAKAGELeakage test was conducted in accordance with AMCA Standard 500-D-98. Holding torque applied was 6 in.-lbs./sq.fton parallel blade dampers. AMCA Standard 500-D-98 states that air leakage is based on operation between 50°F(10°C) and 104°F (40°C).
3960 Standard Installation Duct Frame
Dampers
3
Ratings Based on: AMCA Standard 500-D Intake Ducted Test Figure 5.3 Setup
Tel.: (905) 857-4700 • Fax: (905) 857-4730 • Toll Free: 1-800-668-7214 • www.ventexinc.com
Parallel blade dampers are usedwhen the damper is either open orclosed.
Opposed blade dampers areused to accurately
control the volume of airgoing through
the damper. Tobe used with
modulating actuators.
3961Quick Install Frame –The extruded aluminum hat shapeframe simplifies theinstallation of singlesection and multiplesection dampers significantly reducinglabour costs.
3965BFThermally Broken Frame –Allows the damper to actas a complete thermal barrier stopping thetransfer of heat or
cold along the ductwork.
3967BFSingle Sided flange– The 1” flangearound the perimeter of thisdamper allows for easierinstallation on a wall or on air handling units.
3900 Insulated Control Dampers
4
LinkageSlip proof linkage systemrequires no maintenance for the lifetime of the damper. Castnickel crank arms and 5/16” (8mm) nickel plated steel connec-tion rods that offer superior strength and ensures the actuatortorque is spread evenly across the damper.
Tel.: (905) 857-4700 • Fax: (905) 857-4730 • Toll Free: 1-800-668-7214 • www.ventexinc.com
Dampers
5
3900 Series * STANDARD CONSTRUCTION
Tel.: (905) 857-4700 • Fax: (905) 857-4730 • Toll Free: 1-800-668-7214 • www.ventexinc.com
Depth:4" (101 mm) –3960/39655.25” (133 mm) –3961
Depth with BladesOpen:6.125” (156 mm)
Minimum Height:6” (150 mm) - Single Blade15" (381 mm) -Multiple Blade
Maximum PanelWidth:48" (1219 mm)
Maximum PanelHeight:60" (1524 mm)
Maxximum PanelSize: 20 Sq.Ft.
Maximum SystemPressure:4" w.g. (1 kPa)
OperatingTemperatureRange: -40° to +180° F
Frame: 0.081” (2mm) ExtrudedAluminum
Blade: 0.063” (1.6mm) ExtrudedAluminum filled with2 part polyurethanefoam.
Beariings: 2 pieceacetal bearing. Hexagonouter shell and round
inner sleeve do notallow any metal tometal contact.
Blade Seals: Dualdurometer customdesign bulb seal
Jamb Seals:Extruded Santoprene
Standard MotorInstallation: FieldAdjustable Side ShaftDirect Drive
Linkage:Concealed in Frame(3960/3961)Outside of Frame(3965)
* See Page 9for Available Accessories
The Alumavent3900 Seriesdamper is the smart
choice when selecting
a control damper. You
can rely on its certified
performance, rugged
aluminum construction,
no maintenance linkage
system, and unique frame
designs to save money
from the time it is
installed.
The Standard Nylon BladeEnd Cap maximizes the contactarea of the blade and jamb seals,creating a better seal than the bladeand jamb seal alone. The smoothnylon surface of the end cap alsoensures smooth operation of thedamper and prevents the jamb sealfrom being damaged by the blade.
3165Flanged to Duct Frame – The frame is fasteneddirectly to the flange on the duct. The open area isequal to the duct size. Thismaximizes the free area and is recommended fordampers less than 30”(762 mm) high.
3161Quick Install Frame – The extruded aluminumhat shape frame simplifies the installation of singlesection and multiplesection dampers significantly reducinglabour costs.
3167Single Sided flange– The 1” flangearound theperimeter of thisdamper allows foreasier installationon a wallor on air handling units.
6
3100 Series Air Foil Control Dampers
Tel.: (905) 857-4700 • Fax: (905) 857-4730 • Toll Free: 1-800-668-7214 • www.ventexinc.com
Opposed bladedampers are used to
accurately control the volume of air going
through the damper.To be used with
modulating actuators.
Parallel blade dampers areused when the damper is eitheropen or closed.
3100 SeriesThe Alumavent 3100 is a premium, low leakage, extruded aluminum, airfoil damper. The thin airfoil profile minimizes the pressure drop andnoise through the damper. This makes the 3100 series an excellent
choice for air handlers. The hollow extruded aluminum bladeoffers superior rigidity and minimizes deflection at higher velocities.
3160StandardInstallation Duct Frame
7
s
Tel.: (905) 857-4700 • Fax: (905) 857-4730 • Toll Free: 1-800-668-7214 • www.ventexinc.com
3100 Series * STANDARD CONSTRUCTION
Depth:4" (101 mm) – 3160/31655.25” (133 mm) – 3161
Depth withBlades Open:6.125” (156mm)
MinimumHeight:8” (203 mm) -Single Blade15" (381 mm) -Multiple Blade
MaximumPanel Width:48" (1219 mm)
MaximumPanelHeight:60" (1524 mm)
MaxximumPanel Size: 20Sq.Ft.
MaximumSystemPressure:4" w.g. (1 kPa)
OperatingTemperatureRange: -40° to+180° F
StandardFinish: Mill
StandaardMotorInstallation:6” Side ShaftDirect Drive
Linkage:Concealed inFrame(3160/3161)Outside ofFrame (3165)
Blade EndCap:Nylon
* See Page 9 for Available Accessories
Silicone Blade and Jamb SealsFor extremely cold environments siliconeseals stay flexible to atemperature of -40F (-40C).
Broken FrameA thermally broken framereduces the amount ofthermal transfer from oneside of the damper to theother. The temperaturecan vary as much as 176F (80C) from oneside to the other.
Salt Water ConstructionTo be used in corrosive environments.
The steel components of the linkage are replaced withstainless steel hardware. The blades and frames are
anodized. (Note BF frame construction is not available withSW construction. Parallel blade operation only available).
0 Duct Mount
1 Quick’N’Stall Duct Mount
5 Flanged to Duct Mount
7 Front Flange Mount
8
Naming Convention
Mounting /Naming Convention
Tel.: (905) 857-4700 • Fax: (905) 857-4730 • Toll Free: 1-800-668-7214 • www.ventexinc.com
Flange Frames available for 4000 SeriesSingle Rear Flange:Flange on actuator side of damperSingle Front Flange:Flange on opposite side of actuatorDouble Flange:Flange on both sides of the damper.
Horizontal Jackshafts
9
vention Jack Shaft and Accessories
Tel.: (905) 857-4700 • Fax: (905) 857-4730 • Toll Free: 1-800-668-7214 • www.ventexinc.com
Electric:• Actuators:
Honeywell and Belimoelectric actuators
• 24Vdc, 24Vac, 120Vand 240V all available
with auxiliary switches• Internal and external
mounting.• 2 position (on / off) or
modulating controlwith feedback signal
Manual:• Manual Hand
Quadrants• Chain Operator
Operators
Type STS “Sure Turn System” Is made forindustrial applications where maintenance ondampers is not possible.
The STS features 1” stainless steel precisionshafting. The crank arms are fabricated from2” x 1/4” steel bar, welded to a 2” collar, andfastened to the shaft using a spring pin. Thepush rods are 1/2” diameter, stainless steel,threaded rod, capped with spherical rod endsto drive the damper. The metalized carbonbearings inhibit dirt or debris from gettinginside therefore, no maintenance is required.
Type STS“Sure Turn System”
Type A
Jumpers Field installed jumpers are available to drive a 2 panel damper. Lasercut from 10 Ga galvanized steel it is available to use on dampers under 18 sq.ft.
Vertical Jackshaft Connects two sections of dampers together using 1/2”stainless steel threaded rod and spherical ends.
The 4000 Seriesis Alumavent’s most economical control
damper can be used as a manualdamper as well as standard con-
trol damper in most low tomedium velocity and pressure
HVAC systems.The standardHD frame is roll formedfrom a single piece of16ga. gal. steel to increasethe structural integrityand reduce racking.Thecorners are fastenedtogether using togglelocks that won’tshake loose.
The 16 ga. steelblade features 3 Vgrooves that run thelength of thedamper to increasethe strength of theblade.They are theninstalled in thedamper using custom designed“W” bolts and nylonlock washers thatcan’t come loose.
The 4100is ideal for low leakage
applications due to its dualdurometer blade seals
which do not requireadhesives ormechanical fasten-ers. The com-pressible concavestainless steel jamb
seals ensure a tightseal along the jambs.
The concealed linkagein the frame removes the
linkage from the air stream, andreduces pressure drop.
4000
4100
10
Parallel bladedampers are usedwhen the damper iseither open orclosed.
Tel.: (905) 857-4700 • Fax: (905) 857-4730 • Toll Free: 1-800-668-7214 • www.ventexinc.com
4000 Steel Control Dampers
Standard adjustable drive shaft. The integraldrive shaft can be extended up to 12”it cannot come loose or be lost.
Opposed blade dampersare used to accurately con-trol the volume of air goingthrough the damper. To beused with modulating actuators.
51A Standard
51B B Channel
51C Square Transtion
51CRRound Transition
51COOval Transition
Vertical
Horizontal
11Tel.: (905) 857-4700 • Fax: (905) 857-4730 • Toll Free: 1-800-668-7214 • www.ventexinc.com
pers 5100 Series Fire Dampers
1. Blade: Roll formed 22GA.Galvanized Steel - Interlocking curtain type blade
2. Fusible Link:165°F (73.9°C) Standard212°F (100°C) Optional
3. Link Strap4. Frame: Roll formed 20 GA.
Galvanized Steel with hemmed edge
5. Constant Force Spring6. Lock Ramp
* 4000 Series STANDARD CONSTRUCTION
Depth:5" (127 mm)
Depth with Blades Open:6.375” (162 mm)
Minimum Height:8” (203 mm) - Single Blade14" (356 mm) - Multiple Blade
Maximum Panel Width:48" (1219 mm)
Maximum Panel Height:72" (1829 mm)
Maximmum System Pressure:4" w.g. (1 kPa)
Standard Finish:Mill Galvanized
Standard Motor Installation:Side Shaft Direct Drive - extendableup to 12”
Linkage:Concealed in Frame
* See Page 9 for AvailableAccessories
Fire DampersAlumavent is pleased to introduce
its 1.5 hour UL RatedStandard Curtain Type
Fire Damper.
Fire DamperModel 51A
C US
Distributed by:
Tel.: (905) 857-4700 • Fax: (905) 857-4730Toll Free: 1-800-668-7214
w w w . v e n t e x i n c . c o m
LOUVERS & BACK DRAFT DAMPERS
195 Healey Rd., Bolton, ON L7E 5B2Tel.: (905) 857-4700 Fax: (905) 857-4730
Toll Free: 1-800-668-7214 w w w. ve n t e x i n c . c o m
LOUVERS & BACK DRAFT DAMPERS
Archives of Ontario Building, York University, Toronto, Ontario
See Ventex Cataloguefor more Louvers and Back Draft Dampers
University of Sherbrooke Hospital CenterEmergency Standby GeneratorSherbrooke, Quebec.
Laval Subway Extension,Laval, Quebec