11
Italian quality Since 1957 www.narcisi.it

Italian quality Since 1957 - Roofing Superstore€¦ · . gas torches for bituminous membrane - stem and burner head intitanium - fixed or removable stem - burner head isthreaded

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Italian quality Since 1957 - Roofing Superstore€¦ · . gas torches for bituminous membrane - stem and burner head intitanium - fixed or removable stem - burner head isthreaded

Italian quality

Since 1957

www.narcisi.it

Page 2: Italian quality Since 1957 - Roofing Superstore€¦ · . gas torches for bituminous membrane - stem and burner head intitanium - fixed or removable stem - burner head isthreaded

GAS TORCHES FOR BITUMINOUS MEMBRANE

- STEM AND BURNER HEAD IN TITANIUM

- FIXED OR REMOVABLE STEM

- BURNER HEAD IS THREADED ONTO THE STEM FOR AN EASILY SUBSTITUTION

- DOUBLE KNOB FOR DOUBLE REGULATION OF MIN AND MAX

- SWIVEL CONNECTION TO THE HOSE

- GAS CONSUMPTION SAVINGS THANKS TO THE BALANCE OF AIR-GAS MIX

- STAND INCLUDED

- ALL MANUFACTURED ACCORDING TO EUROPEAN REGULATIONS ISO EN9012

The NEPTUNE

2

BURNER

HEAD

(MM.)

STEM

(MM.)

WEIGHT

(GR.)KCAL/H KW KJ/H

WORKING

PRESSURE

BAR

MAX

CONSUMPTION

KG/H

50 180/350 600/625 53550 62,27 224162 2 – 4 4,5

60 180/350 645/670 64260 74,72 268995 2 – 4 5,4

Page 3: Italian quality Since 1957 - Roofing Superstore€¦ · . gas torches for bituminous membrane - stem and burner head intitanium - fixed or removable stem - burner head isthreaded

3

- STEM AND KNOB IN BRASS

- FIXED OR REMOVABLE STEM

- EACH SINGLE CONNECTION BRAZED WITH AG45 SILVER ALLOY

- BURNER HEAD IS THREADED ONTO THE STEM FOR AN EASILY SUBSTITUTION

- DOUBLE KNOB FOR DOUBLE REGULATION OF MIN AND MAX

- SWIVEL CONNECTION TO THE HOSE

- GAS CONSUMPTION SAVINGS THANKS TO THE BALANCE OF AIR-GAS MIX

- STAND INCLUDED

- ALL MANUFACTURED ACCORDING TO EUROPEAN REGULATIONS ISO EN9012

BURNER

HEAD

(MM.)

STEM

(MM.)

WEIGHT

(GR.)KCAL/H KW KJ/H

WORKING

PRESSURE

BAR

MAX

CONSUMPTION

KG/H

50 200/300/400 750/770/810 53550 62,27 224162 2 – 4 4,5

60 200/300/400 815/835/875 64260 74,72 268995 2 – 4 5,4

70 200/300/400 865/885/925 71400 83,02 298883 2 – 4 6,0

The DELUXE

GAS TORCHES FOR BITUMINOUS MEMBRANE

Page 4: Italian quality Since 1957 - Roofing Superstore€¦ · . gas torches for bituminous membrane - stem and burner head intitanium - fixed or removable stem - burner head isthreaded

The ECOGAS

- STEM AND KNOB IN BRASS

- EACH SINGLE CONNECTION BRAZED WITH AG45 SILVER ALLOY

- BURNER HEAD IS THREADED ONTO THE STEM FOR AN EASILY SUBSTITUTION

- DOUBLE KNOB FOR DOUBLE REGULATION OF MIN AND MAX

- GAS CONSUMPTION SAVINGS THANKS TO THE BALANCE OF AIR-GAS MIX

- STAND INCLUDED

- ALL MANUFACTURED ACCORDING TO EUROPEAN REGULATIONS ISO EN9012

BURNER

HEAD

(MM.)

STEM

(MM.)

WEIGHT

(GR.)KCAL/H KW KJ/H

WORKING

PRESSURE

BAR

MAX

CONSUMPTION

KG/H

50 200/300/400 640/685/725 53550 62,27 224162 2 – 4 4,5

60 200/300/400 745/790/830 64260 74,72 268995 2 – 4 5,4

70 200/300/400 795/840/880 71400 83,02 298883 2 – 4 6,0

4

GAS TORCHES FOR BITUMINOUS MEMBRANE

Page 5: Italian quality Since 1957 - Roofing Superstore€¦ · . gas torches for bituminous membrane - stem and burner head intitanium - fixed or removable stem - burner head isthreaded

5

The LIGHT

- STEM IN IRON

- STEM LIGHTER THAN THE DELUXE AND ECOGAS AS IT HAS A SMALLER DIAMETER

- STEM REMOVABLE FROM HANDLE

- DOUBLE KNOB FOR DOUBLE REGULATION OF MIN AND MAX

- GAS CONSUMPTION SAVINGS THANKS TO THE BALANCE OF AIR-GAS MIX

- STAND INCLUDED

- ALL MANUFACTURED ACCORDING TO EUROPEAN REGULATIONS ISO EN9012

BURNER

HEAD

(MM.)

STEM

(MM.)

WEIGHT

(GR.)KCAL/H KW KJ/H

WORKING

PRESSURE

BAR

MAX

CONSUMPTION

KG/H

50 270/400 650/680 64260 74,72 268995 2 – 4 5,4

60270/400

760/790 71400 83,02 2988832 – 4

6,0

70 270/400 830/860 78540 91,32 3288312 – 4

6,6

GAS TORCHES FOR BITUMINOUS MEMBRANE

Page 6: Italian quality Since 1957 - Roofing Superstore€¦ · . gas torches for bituminous membrane - stem and burner head intitanium - fixed or removable stem - burner head isthreaded

6

COMPLETE KIT

Kit NEPTUNE

- SINGLE GAS TORCH MODEL NEPTUNE

- 10 MT. GAS PROPANE RUBBER HOSE

- 8 KG. GAS REGULATOR ACCORDING TO THE COUNTRY REGULATIONS OR EVENTUAL ADAPTER FOR THE GAS BOTTLE CONNECTION USED IN EACH COUNTRY

- SAFETY VALVE INCLUDED

- ACCORDING TO EUROPEAN REGULATIONS ISO EN9012, ISO EN3821, ISO EN16129

BURNER

HEAD

(MM.)

STEM

(MM.)

WEIGHT

(GR.)KCAL/H KW KJ/H

WORKING

PRESSURE

BAR

MAX

CONSUMPTION

KG/H

50 180/350 600/625 53550 62,27 224162 2 – 4 4,5

60 180/350 645/670 64260 74,72 268995 2 – 4 5,4

Page 7: Italian quality Since 1957 - Roofing Superstore€¦ · . gas torches for bituminous membrane - stem and burner head intitanium - fixed or removable stem - burner head isthreaded

7

Kit DELUXE

- SINGLE GAS TORCH MODEL DELUXE

- 10 MT. GAS PROPANE RUBBER HOSE

- 12 KG. GAS REGULATOR ACCORDING TO THE COUNTRY REGULATIONS OR

EVENTUAL ADAPTER FOR THE GAS BOTTLE CONNECTION USED IN EACH COUNTRY

- SAFETY VALVE INCLUDED

- ACCORDING TO EUROPEAN REGULATIONS ISO EN9012, ISO EN3821, ISO EN16129

BURNER

HEAD

(MM.)

STEM

(MM.)

WEIGHT

(GR.)KCAL/H KW KJ/H

WORKING

PRESSURE

BAR

MAX

CONSUMPTION

KG/H

50 200/300/400 750/770/810 53550 62,27 224162 2 – 4 4,5

60 200/300/400 815/835/875 64260 74,72 268995 2 – 4 5,4

70 200/300/400 865/885/925 71400 83,02 298883 2 – 4 6,0

COMPLETE KIT

Page 8: Italian quality Since 1957 - Roofing Superstore€¦ · . gas torches for bituminous membrane - stem and burner head intitanium - fixed or removable stem - burner head isthreaded

8

Kit ECOGAS

- SINGLE GAS TORCH MODEL ECOGAS

- 10 MT. GAS PROPANE RUBBER HOSE

- 12 KG. GAS REGULATOR ACCORDING TO THE COUNTRY REGULATIONS OR EVENTUAL

ADAPTER FOR THE GAS BOTTLE CONNECTION USED IN EACH COUNTRY

- ACCORDING TO EUROPEAN REGULATIONS ISO EN9012, ISO EN3821, ISO EN16129

BURNER

HEAD

(MM.)

STEM

(MM.)

WEIGHT

(GR.)KCAL/H KW KJ/H

WORKING

PRESSURE

BAR

MAX

CONSUMPTION

KG/H

50 200/300/400 640/685/725 53550 62,27 224162 2 – 4 4,5

60 200/300/400 745/790/830 64260 74,72 268995 2 – 4 5,4

70 200/300/400 795/840/880 71400 83,02 298883 2 – 4 6,0

COMPLETE KIT

Page 9: Italian quality Since 1957 - Roofing Superstore€¦ · . gas torches for bituminous membrane - stem and burner head intitanium - fixed or removable stem - burner head isthreaded

9

Kit LIGHT

- SINGLE GAS TORCH MODEL LIGHT

- DIRECT CONNECTION TO THE HOSE

- 10 MT. GAS PROPANE RUBBER HOSE

- 8 KG. GAS REGULATOR AND EVENTUAL ADAPTER FOR THE GAS BOTTLE CONNECTION USED IN EACH COUNTRY

- ACCORDING TO EUROPEAN REGULATIONS ISO EN9012, ISO EN3821, ISO EN16129

BURNER

HEAD

(MM.)

STEM

(MM.)

WEIGHT

(GR.)KCAL/H KW KJ/H

WORKING

PRESSURE

BAR

MAX

CONSUMPTION

KG/H

50 270/400 650/680 64260 74,72 268995 2 – 4 5,4

60270/400

760/790 71400 83,02 2988832 – 4

6,0

70 270/400 830/860 78540 91,32 3288312 – 4

6,6

COMPLETE KIT

Page 10: Italian quality Since 1957 - Roofing Superstore€¦ · . gas torches for bituminous membrane - stem and burner head intitanium - fixed or removable stem - burner head isthreaded

10

ROOFING EQUIPMENTS

ROLLER JOINT-SEAL KITSPATULA

WITH HANDLE

ROLL

OUT HOOK

ROLLER 6kg

FOR SELF ADHESIVEHAND ROLLER

AND TROWELS

HEATER BAND

FOR GAS CYLINDERLEISTER TRIAC AT CUTTER

Page 11: Italian quality Since 1957 - Roofing Superstore€¦ · . gas torches for bituminous membrane - stem and burner head intitanium - fixed or removable stem - burner head isthreaded

11

NARCISICONTACTS

CONTACTS

• Via Dei Pioppi, 22 Padulle

• 40010 Sala BologneseBologna (BO) - ITALY

• E-Mail: [email protected]

• Skype: Narcisi Srl

• Web site: www.narcisi.it

• Tel. (+39) 051 6821320Fax (+39) 051 6821854