FOR ASSISTANCE: [email protected] +39-080-5856-200 SIRIO Specialised kit installation INSTRUCTIONS B. Needle insertion and block A. Needle sensor MOUNTING INSTRUCTIONS NEEDLE SENSOR MOUNTING Insert the needle in the insertion section of the needle sensor(Fig.A) by pushing it gently until it reaches the bottom (figure B). For some needle models, the direction of insertion in coupling section is obliged. ATTENTION The detailed description of SIRIO's intervention specialised kit is provided in the related User Manual, a prior lecture being recommended. Component description and general fitting instructions are presented below. Needle support (not included in the package) 3. Manoeuvrer 1. Patient sensor 2. Needle sensor PACKAGE CONTENT The specialised intervention kit contains: Patient sensor Needle sensor Manoeuvrer The Needle support is an accessory that is not included in the package, but is a fundamental part of the system operation. Please refer to the "Rapid use manual" for operations sequence of to be performed in the procedure of intervention with the SIRIO system POSTURAL MARKER POSITIONING (OPTIONAL) Place adhesive markers for patient's posture monitoring so (1) are hidden during operation as little as possible;(2) should be sufficiently distant from one another and do not form symmetric arrangements. USE WARNING The intervention specialised kit must be used exclusively in association with the SIRIO system and as described in the manual. MASMEC s.p.a. disclaims all

Istruzioni KIT_v4.1 Eng

Embed Size (px)

DESCRIPTION

manual

Citation preview

Page 1: Istruzioni KIT_v4.1 Eng

FOR ASSISTANCE: [email protected]+39-080-5856-200

SIRIO

Specialised kit installation

INSTRUCTIONSB. Needle insertion and block

A. Needle sensor

MOUNTING INSTRUCTIONS

NEEDLE SENSOR MOUNTING Insert the needle in the insertion section of the needle sensor(Fig.A) by pushing it gently until it reaches the bottom (figure B). For some needle models, the direction of insertion in coupling section is obliged.

ATTENTION

The detailed description of SIRIO's intervention specialised kit is provided in the related User Manual, a prior lecture being recommended. Component description and general fitting instructions are presented below.

Needle support (not included in the package)3. Manoeuvrer

1. Patient sensor2. Needle sensor

PACKAGE CONTENTThe specialised intervention kit contains:Patient sensorNeedle sensorManoeuvrer

The Needle support is an accessory that is not included in the package, but is a fundamental part of the system operation.

Please refer to the "Rapid use manual" for operations sequence of to be performed in the procedure of intervention with the SIRIO systemPOSTURAL MARKER POSITIONING (OPTIONAL)Place adhesive markers for patient's posture monitoring so (1) are hidden during operation as little as possible;(2) should be sufficiently distant from one another and do not form symmetric arrangements.

USE WARNING The intervention specialised kit must be used exclusively in association with the SIRIO system and as described in the manual. MASMEC s.p.a. disclaims all liability for damage resulting from improper use of the system.

Insertion clip particularityManouvrer assembling on the needle support.

MANOUVRER MOUNTINGInsert the manouvrer in the needle's support special coloured head until you hear a click .

Warnings and Precautions

Page 2: Istruzioni KIT_v4.1 Eng

This device is designed to be used by a doctor or a health care practitioner who is trained for it's use.

These instructions are not intended to define or suggest any prior medical or surgical procedure. The doctor is responsible for the process and techniques of current use of this device.

Agnolige the expiration date before opening.

Always consider the possibility of allergic reactions.

Discard after use as hospital infected rejection in compliance with current legislation.

Store in a cool place, away from light.

Sterilized with ethylene oxide

Check the integrity of the package; sterility is guaranteed only if the package is unopened. In case of a package is not complete do not use the device.

Integrity and sterility are only guaranteed if storage conditions are fulfilled respected

This device is sterile, pyrogen-free, disposable.

You cannot use the device in Magnetic Resonance.

0476