4
SYSTEM Q-Eye MAG Pulse Direct Current Technology Multi Purpose Flow Measurement System FLOWMONITORINGINTELLIGENCE HydroVision applies a quality management system according to DIN EN ISO 9001:2000 ISO 9001 CERTIFIED JIL HydroVision Your Vision - Our Technology

ISO9001 CERTIFIED HydroVisionapplies …Features Q-Vision Q-Vision isasoftwaresystemthat integratessettingupandautomated collection,reporting,viewingand analysisofdatafromsanitarysewers

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ISO9001 CERTIFIED HydroVisionapplies …Features Q-Vision Q-Vision isasoftwaresystemthat integratessettingupandautomated collection,reporting,viewingand analysisofdatafromsanitarysewers

SYSTEM Q-Eye MAGPulse Direct Current Technology

Multi PurposeFlow Measurement System

FLOWMONITORINGINTELLIGENCE

HydroVision appliesa quality managementsystem according toDIN EN ISO 9001:2000

ISO 9001CERTIFIED

JILHydroVisionYour Vision - Our Technology

Page 2: ISO9001 CERTIFIED HydroVisionapplies …Features Q-Vision Q-Vision isasoftwaresystemthat integratessettingupandautomated collection,reporting,viewingand analysisofdatafromsanitarysewers

Measuring PrincipleMagnetic-inductive flow measurements arebased on Faraday’s law, where a conductormoving in a magnetic field induces a voltageof amplitude proportional to the velocity ofthe conductor.

Measured voltage vertical to the directionof flow and magnetic field which ismeasured at two electrodes.Magnetic inductionVelocityDistance between the electrodes

U :

B:V:L:

M

U = B x V x LM

Welding Socket

Insertion Sensor

Mouse Sensor

“Mini Mouse”

Application with pipe saddle Application in an open channel

Application with welding socket

Pipe Saddle

Transmitter

Q-Eye MAG FeaturesØØ

ØØØØ

Ø

State-of-the-art electromagnetic sensorsSensor reads velocity directly from flowusing PDC-principleSelf-cleaning electrodes suitable for even dirty mediaInsertion sensors for pipes 50 to 500 mm (2 to 20 in.)Open channel sensorsHigh accuracy water depth sensors, hydrostaticpressure, air ultrasonic, bubbler etc.Optional ATEX-Approvals

Page 3: ISO9001 CERTIFIED HydroVisionapplies …Features Q-Vision Q-Vision isasoftwaresystemthat integratessettingupandautomated collection,reporting,viewingand analysisofdatafromsanitarysewers

Features

Q-Vision

Q-Vision

is a software system thatintegrates setting up and automatedcollection, reporting, viewing andanalysis of data from sanitary sewers,combined sewer overflows, stormsewers, rainfall gauges, water qualitysamplers, and pump stat ions.

is an easy-to-use programdesigned to operate under a variety ofhardware and software configurations.The software package operates as acomplete data acquisition and analysissystem in the stand alone mode, or asa work station in a networkenvironment. The software operateson an IBM-PC or compatible and alsoon a hand-held Personal DigitalAssistant (PDA).

Ø

Ø

Ø

Ø

Ø

Ø

Ø

Ø

Ø

Ø

Set-up module for configuration,operation and data collection fromindividual sites and system monitors.

Analysis module for graphicaland numerical representation andevaluation/analysis.

Representation of up to 3individual plots with additionalgraphical super-positioning.

Representation in differentdimensions and time series withdistinctive y-axis.

Span set-up and scatter plotanalysis for data QA/QC and editingpossibilities.

Zoom and cursor positioningfunctions.

Multiple equation flow calculationswith different channel shape and sizes.

Complete statistical calculations(min., max. ,average and total flowsstd. dev.), including mass balancing

(inflows, outflows, etc.)

Export of data as ASCII andcsv-files for other 3 Party software(e.g. hydraulic models, etc).

Import of rainfall data from anyrain logger.

rd

Flow Calculations

Scatter graphs

Sewer Flow Analysis

The software incorporates several flow equations includingPrandtl Colebrook, Continuity, and custom cross-sections(for non-standard pipe sizes, irregular channel sizes), andsilt levels.

On-screen graphics allows the user to determine the accuracyof the depth and velocity data and perform complete QA/QCon the flow data and determine anomalous conditions.

Composite and comparative graphs and tables allow the user todetermine trends, analyze net flows for I/I analysis, billingnetworks, pipe capacities and mass balancing.

Flow and sensor data can be reported in graphic and tabularform, either on-screen or hard copy, with a wide selection ofprinter capabilities. Reports can be prepared as standard tabularand graphic reports and outputs include daily, weekly, monthlyor yearly reports and statistical functions for min., max., meanand totals including standard deviations and regression analysis.Data can also be output in ASCII and cvs format.

Reporting

Page 4: ISO9001 CERTIFIED HydroVisionapplies …Features Q-Vision Q-Vision isasoftwaresystemthat integratessettingupandautomated collection,reporting,viewingand analysisofdatafromsanitarysewers

HydroVision GmbHGewerbestrasse 61A

87600 KaufbeurenGermany

Phone: +49 83 41 966-2180Fax: +49 83 41 966-6030

E-Mail: [email protected]://www.hydrovision.de

Represented by:

HydroVision reserves the right to alter specifications without notice. 01/2006

TRANSMITTER

TYPE:LC-DISPLAY:

KEYPAD:MEMORY CAPACITY:

LOGGING INTERVALS:MEMORY LIFE:

POWER:CLOCK:

COMMUNICATIONS:

INPUTS:

OUTPUTS:

TEMPERATURE RANGE:SIZE:

WEIGHT:MATERIAL:

PROTECTION:

SENSOR

TYPE:

DEPTH:Range:

Accuracy:

VELOCITY:Range:

Accuracy:

MATERIAL:

PROTECTION:APPROVALS:

Microcontoller based transmitter, stationary4 Lines, 20 characters, alphanumeric5 ButtonsUp to 2 Gbytes, removable Compact Flash1,2,5,10,15,30,60 mins., programmable>5 years, typical (@5min. intervals, depth and velocity)100 - 230 V , or 12 VReal Time Clock, battery buffered

USB host device controllerModem telemetry / Ethernet (optional)Type: GSM and CCITT V.22, full duplexData Rate: 9600 bps, asynchronous

Up to 8 analog, 0/4 - 20 mA (galvanically isolated) or 0 - 1/5 VUp to 4 digital (TTL-Level, 5 Volt)Up to 4 analog, 0/4 - 20 mA (galvanically isolated) or 0 - 1/5 VUp to 2 digital, open collector max. 40 VDC - 250 mAUp to 2 relays (250 VAC /1A or 60 VDC/0.5A)

-10°C to +70°C (-4°F to + 160°F)W=26.5 cm (10.4"), H=24.1 cm (9.5"), D=10.4 cm (4.1”)8,2 kg (18lbs)AluminiumIP65 (NEMA 4)

Electromagnetic velocity and hydrostatic pressure depthWedge (mouse) type or insertion typePDC-Principle (Pulse Direct Current)Minimum conductivity 10 S/mStandard cable length 10 m (33 ft), max. 100 m (330 ft),

0 to 2 m (0 to 6.6 ft) for hydrostatic type (other ranges optional)< +/- 0.25%

-6 to +6 m/s (-20 to +20 fps), bi-directional+/-1% of velocity reading or +/-0.03 m/s

Sensor electrodes: stainless steel, Titan, HastelloySensor body: PE-UHM or PVDFIP68ATEX (optional)

Q-EYE MAG

AC DC

µ