Intumescent Fire Dampers Intumescent Fire Dampers

Intumescent Fire Dampers - Celmec Internationalbrochures.celmec.net/celmec_intumescent_fire... · WSW1 Masonry-/120/-LVH44 Mounted in riser branch (angle free system) FCO1868 300

  • Upload
    others

  • View
    3

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Intumescent Fire Dampers - Celmec Internationalbrochures.celmec.net/celmec_intumescent_fire... · WSW1 Masonry-/120/-LVH44 Mounted in riser branch (angle free system) FCO1868 300

Intumescent Fire DampersIntumescent Fire Dampers

Page 2: Intumescent Fire Dampers - Celmec Internationalbrochures.celmec.net/celmec_intumescent_fire... · WSW1 Masonry-/120/-LVH44 Mounted in riser branch (angle free system) FCO1868 300

Intumescent Fire Dampers

Contents

Introduction 1

Lorient Intumescent Fire Dampers 2

LVH-O, LVH-O Hi Flo, LVH-OSS, LVH-D 3

LVH44, LVH-C, LVH - Hi Flo 4

Lorient System Selector 5

Celmec International Pty Ltd ACN 005 850 546Melbourne Tel: +61 3 8552 8200 Fax: +61 3 9555 9723

Sydney Tel: +61 2 8436 7200 Fax: +61 2 8436 7211

REF 010714

Page 3: Intumescent Fire Dampers - Celmec Internationalbrochures.celmec.net/celmec_intumescent_fire... · WSW1 Masonry-/120/-LVH44 Mounted in riser branch (angle free system) FCO1868 300

- 1 - www.celmec.com.au

Intumescent Fire Dampers

Celmec International

Leading the way in Air Control, Heating & Cooling

At Celmec International, it is our belief that working closely with our clients aids the mutual success of both organisations and for this reason we have adopted the following mission:

“To excel in the commercial and industrial building industry by setting new standards with innovative products through leadership, first class customer service and engineering excellence.”

It is with confidence that we at Celmec International offer the Lorient Intumescent Fire Dampers.

Page 4: Intumescent Fire Dampers - Celmec Internationalbrochures.celmec.net/celmec_intumescent_fire... · WSW1 Masonry-/120/-LVH44 Mounted in riser branch (angle free system) FCO1868 300

- 2 - www.celmec.com.au

Standards & Codes

Relevant standards and codes relating to Fire damper Performance, Fire Resistance, installation and maintenance include:

• AS 1668.1 Design• AS 1530.4 Fire test methodology• AS 1682.1 Air leakage testing / design• AS 1682.2 Installation• AS 1851.6 Maintenance

Intumescent Fire Dampers

Never before has a Fire Damper offered so much flexibility!

Lorient LVH SeriesIntumescent Fire DampersIFD’s are designed to seal penetrations provided for movement of air via ducted or naturally ventilated means.

Lorient LVH series of IFD’s have no moving parts providing a reliability unmatched by conventional mechanical type fire dampers.

The Operation of the Lorient LVH series IFD’s is by heat activation of the intumescent material. The Intumescent swells many times its original thickness to form a solid barrier to fire.

This mode of operation means that the Lorient LVH series intumescent fire dampers are bi-directional. In addition they are not affected by building movement or thermal expansion if built or cast into the opening.

Regulatory RequirementsTo comply with the Building Code of Australia and referenced standard AS 1668.1. Lorient LVH Series IDF’s are fully fire tested in accordance with AS 1682.1.

Comprehensive approvals provide users with confidence to specify Lorient intumescent fire dampers for both “Deemed to Satisfy” and “performance based alternative solutions”.

Lorient Website

www.lorient.com.au

• Catalogue information• Product data technical sheets• Design data for perfomance based systems• Drawing register• Applications and approvals• Latest news of products, applications people etc.

Page 5: Intumescent Fire Dampers - Celmec Internationalbrochures.celmec.net/celmec_intumescent_fire... · WSW1 Masonry-/120/-LVH44 Mounted in riser branch (angle free system) FCO1868 300

- 3 - www.celmec.com.au

Intumescent Fire Dampers

Lorient Intumescent Fire Dampers

LVH-O

Features

• Cost effective solution• Innovative & easy to install light weight design• Suitable for extract and supply systems in commer-

cial, industrial and residential projects• No hazardous fibrous packing required• No thermal clearances required in installation• Reduced maintenance & resultant cost savings• Also available as LVH-OSS for aggressive environments

Technical Data

• Integrity Fire Rating - up to 4 hours• Sizes available 100mm to 450mm Dia• Galvanized sleeve (spigot) 360mm long

LVH-O HI FLO

Features

• Clever new Hi Flo design with significantly reduced pressure drop

• Suitable for exhaust systems where every Pa saved can mean reduced fan sizing & resultant power savings

• System Acoustic benefits• No thermal clearances required in installation• Reduced maintenance & resultant cost savings• Also available in rectangular LVH44 Hi Flo design

Technical Data

• Integrity Fire Rating - up to 2 hours• Sizes available 150mm & 200mm Dia• Galvanized sleeve (spigot) 360mm long• Intumescent cell only is available

LVH-OSS

Features

• Cost effective solution• Stainless steel sleeve• No hazardous fibrous packing required• Reduced maintenance & resilient cost savings• Available with Halar coating for hazardous

environments

Technical Data

• Integrity Fire Rating - up to 2 hours• Sizes available 100mm to 450mm Dia• Stainless steel sleeve (spigot) 360mm long• Halar Coating option

LVH-D

Features

• Innovative slimline design• Suitable for both mini & maxi fire doors• All in one kit includes 1 x IFD, 2 x cover grilles,

Lorient Mastic & fixings• Easy installation in new or existing doors

Technical Data

• Integrity Fire Rating - 2 hours• Insulation Fire Rating 1/2 hour• Sizes available 600 x 300mm, 450 x 450mm & 600

x 600mm (Pyropanel doors only)• Suits 35mm and 45mm thick Fire Doors

Page 6: Intumescent Fire Dampers - Celmec Internationalbrochures.celmec.net/celmec_intumescent_fire... · WSW1 Masonry-/120/-LVH44 Mounted in riser branch (angle free system) FCO1868 300

- 4 - www.celmec.com.au

Intumescent Fire Dampers

LVH44

Features

• Innovative and slimline design• Simple Installation• Suitable for retrofit of seized mechanical dampers• Approvals for Wall, Floor & Ceiling mounting• No thermal expansion clearances during install• Reduced maintenance & resultant cost savings

Technical Data

• Integrity Fire Rating - up to 4 hour• Damper depth 44mm• Sizes available from 45mm to over 10,000mm

LVH44 CASED

Features

• Insulating Wall & Floor mount• Includes sleeve & flanges• Can be cast in situ or retro fitted• No hazardous fibrous packing required• No thermal expansion clearances during install• Reduced maintenance & result cos savings

Technical Data

• Integrity Fire Rating - up to 4 hour• Insulation Fire Rating - 2 hour plus• Sizes available 150 x 150mm, 200 x 200mm,

250 x 250mm, 300 x 300mm

LVH-C

Features

• Moisture resistant• Innovative light weight design• Space savings compared to old Rat Trap designs• Suitable for use with supply grilles & return air

diffusers• Reduced maintenance & resultant cost savings• Ideal for a retrofit in Fire safety upgrades

Technical Data

• Integrity Fire Rating - up to 1 1/2 hour• Insulation Fire Rating - up to 1 1/2 hour• Sizes available up to 600 x 600mm

Page 7: Intumescent Fire Dampers - Celmec Internationalbrochures.celmec.net/celmec_intumescent_fire... · WSW1 Masonry-/120/-LVH44 Mounted in riser branch (angle free system) FCO1868 300

Pene

trat

ion

Syst

emB

uild

ing

Elem

ent

FRL

Prod

uct

App

licat

ion

/ Mou

ntin

g D

etai

lA

ppro

val R

ef.

Max

. Siz

eC

ondi

tion

Wal

lW

M1

Mas

onry

-/120

/-LV

H44

Mou

nted

in s

teel

cas

ing

in p

enet

ratio

nFC

O26

43, F

CO

1741

1200

mm

x >

10m

, >10

m x

120

0mm

WM

2M

ason

ry-/2

40/-

LVH

44 C

ased

Mou

nted

in s

teel

cas

ing

in p

enet

ratio

nC

9151

025

0 x

250m

mW

M3

Mas

onry

-/120

/-LV

H44

NO

cas

ing

in p

enet

ratio

nFC

O26

4360

0mm

x >

10m

, >10

m x

600

mm

WM

4M

ason

ry-/1

20/-

LVH

44N

O c

asin

g - s

urfa

ce m

ount

ed o

ver p

enet

ratio

nFC

O17

4060

0 x

600m

mm

ax h

ole

size

500

mm

x 5

00m

mW

M5

Mas

onry

-/120

/-LV

H-O

Stee

l sle

eve

in p

enet

ratio

n22

774-

0145

0mm

dia

met

erW

M6

Mas

onry

-/240

/-LV

H-O

Stee

l sle

eve

in p

enet

ratio

n22

774-

0115

0mm

dia

met

erW

M7

Mas

onry

-/120

/-LV

H-O

SSSt

ainl

ess

stee

l sle

eve

in p

enet

ratio

n22

774-

0145

0mm

dia

met

erW

M8

Mas

onry

-/120

/-LV

H-O

Spira

l duc

t sle

eve

grou

ted

into

pen

etra

tion

(ang

le fr

ee)

FCO

2008

300m

m d

iam

eter

WM

9M

ason

ry-/1

20/-

LVH

-Hi F

loM

ount

ed in

ste

el c

asin

g in

pen

etra

tion

FCO

2564

250m

m x

400

mm

WM

10M

ason

ry-/1

20/-

LVH

O-H

i Flo

Stee

l sle

eve

in p

enet

ratio

nFC

O25

6425

0mm

dia

met

erW

M11

Mas

onry

-/120

/-LV

H44

NO

cas

ing

with

var

ious

fixi

ng b

rack

ets

FCO

1854

600m

m x

>10

m

WH

1H

ebel

75S

S-/1

20/-

LVH

44M

ount

ed in

ste

el c

asin

g in

pen

etra

tion

FCO

2325

1200

H x

600

mm

W *d

ual p

anel

400m

m m

ax if

in s

ingl

e in

pan

elW

H2

Heb

el 7

5SS

-/120

/-LV

H-O

Mou

nted

in s

teel

cas

ing

in p

enet

ratio

nFC

O23

2545

0mm

dia

. *du

al p

anel

400m

m m

ax if

in s

ingl

e in

pan

elW

H3

Heb

el 7

5SW

-/120

/-LV

H44

Mou

nted

in s

teel

cas

ing

in p

enet

ratio

nFC

O23

2512

00 H

x 6

00m

m W

*dua

l pan

el

400m

m m

ax if

in s

ingl

e in

pan

elW

H4

Heb

el 7

5SW

-/120

/-LV

H-O

Stee

l cas

ing

in p

enet

ratio

nFC

O23

2545

0 di

a. *d

ual p

anel

400m

m m

ax if

in s

ingl

e in

pan

elW

H5

Heb

el 7

5SW

-/120

/-LV

H44

Stee

l sle

eve

posi

tione

d tig

ht to

und

ersi

de o

f sla

bFC

O23

2530

0mm

x 3

00m

mW

H6

Heb

el 7

5SW

-/120

/-LV

H-O

Stee

l spi

got p

ositi

oned

tigh

t to

unde

rsid

e of

sla

bFC

O23

2515

0mm

dia

met

erW

H7

Heb

el 7

5SW

-/120

/-LV

H44

Stee

l cas

ing

tight

to u

nder

side

of s

lab

with

3 a

ngle

sFC

O23

2530

0mm

x 3

00m

m

WS1

CSR

Sec

urity

wal

l-/9

0/90

LVH

44M

ount

ed in

ste

el c

asin

g in

pen

etra

tion

4595

560

0 x

600m

m

WS2

CSR

Sec

urity

wal

l-/9

0/-

LVH

-OSt

eel s

leev

e in

pen

etra

tion

FCO

2436

300m

m d

iam

eter

WP1

FR P

l/Boa

rd 2

x 1

laye

r-/1

20/-

LVH

44M

ount

ed in

ste

el c

asin

g in

pen

etra

tion

FCO

1870

600m

m x

600

mm

WP2

FR P

l/Boa

rd 3

laye

rs-/1

20/-

LVH

44M

ount

ed in

ste

el c

asin

g in

pen

etra

tion

FCO

1870

600m

m x

600

mm

WP3

FR P

l/Boa

rd 2

x 2

laye

rs-/1

20/-

LVH

-OSt

eel s

leev

e in

pen

etra

tion

FCO

2203

450m

m d

iam

eter

WP4

FR P

l/Boa

rd 2

5mm

line

r + 2

laye

rs -

/120

/-LV

H-O

Stee

l sle

eve

in p

enet

ratio

nFC

O22

0345

0mm

dia

met

erW

P5FR

Pl/B

oard

3 la

yers

+ 1

laye

r pad

-/120

/-LV

H-O

Mou

nted

in s

teel

sle

eve

in p

enet

ratio

nFC

O22

0345

0mm

dia

met

erW

P6FR

Pl/B

oard

3 la

yers

-/120

/-LV

H-O

Stee

l sle

eve

in p

enet

ratio

nFC

O22

0345

0mm

dia

met

erW

P7FR

Pl/B

oard

2 x

2 la

yers

-/120

/-LV

H44

NO

cas

ing

in p

enet

ratio

nFC

O18

5460

0mm

x 6

00m

m

Shaf

twal

lW

SW1

Mas

onry

-/120

/-LV

H44

Mou

nted

in ri

ser b

ranc

h (a

ngle

free

sys

tem

)FC

O18

6830

0 x

300m

m o

r 90,

000m

m2

Duc

tW

SW2

Mas

onry

-/120

/-LV

H44

Mou

nted

in ri

ser b

ranc

h tig

ht to

sla

b w

ith p

acke

rFC

O24

3690

,000

mm

2

WSW

3M

ason

ry-/1

20/-

LVH

-OM

ount

ed in

rise

r bra

nch

(ang

le fr

ee s

yste

m)

FCO

2455

300m

m d

iam

eter

WSW

4FR

Pl/B

oard

3 la

yers

-/120

/-LV

H44

Mou

nted

in ri

ser b

ranc

h tig

ht to

sla

b w

ith p

acke

rFC

O24

3630

0 x

300m

m o

r 90,

000m

m2

WSW

5FR

Pl/B

oard

3 la

yers

-/120

/-LV

H44

Mou

nted

in ri

ser b

ranc

h tig

ht to

sla

b w

ith IB

S ro

d &

mas

ticFC

O24

3630

0 x

300m

m o

r 90,

000m

m2

WSW

6FR

Pl/B

oard

3 la

yers

-/120

/-LV

H-O

Mou

nted

in ri

ser b

ranc

h (a

ngle

free

sys

tem

)FC

O24

5530

0mm

dia

met

erW

SW7

FR P

l/Boa

rd 3

laye

rs-/1

20/-

LVH

44M

ount

ed in

rise

r bra

nch

(ang

le fr

ee s

yste

m)

FCO

1869

300

x 30

0mm

or 9

0,00

0mm

2

WSW

8FR

Pl/B

oard

2 x

2 la

yers

-/120

/-LV

H44

Mou

nted

in ri

ser b

ranc

h (a

ngle

free

sys

tem

)FC

O18

6930

0 x

300m

m o

r 90,

000m

m2

WSW

9FR

Pl/B

oard

2 x

2 la

yers

-/120

/-LV

H-O

Mou

nted

in ri

ser b

ranc

h (a

ngle

free

sys

tem

)FC

O24

5530

0mm

dia

met

erW

SRF1

Ret

rofit

sha

ftwal

l opt

ion

-/120

/-LV

H44

Ret

rofit

fixi

ng ta

bs in

exi

stin

g da

mpe

r hou

sing

sFC

O21

0130

0 x

300m

m

Floo

r / S

lab

FL1

Con

cret

e sl

ab-/1

20/-

LVH

44M

ount

ed in

ste

el c

asin

g in

pen

etra

tion

FCO

2643

/FC

O19

63U

p to

120

0mm

x >

10m

or >

10m

x 1

200m

mFL

2C

oncr

ete

slab

-/120

/120

LVH

44 C

ased

Mou

nted

in s

teel

cas

ing

in p

enet

ratio

nFS

P068

730

0 x

300m

mFL

3C

oncr

ete

slab

-/120

/120

LVH

44N

O c

asin

g in

pen

etra

tion

FCO

1796

600

x 60

0mm

FL4

Con

cret

e sl

ab-/1

20/-

LVH

-OSt

eel s

leev

e in

pen

etra

tion

FCO

1866

300m

m d

iam

eter

FL5

Con

cret

e sl

ab-/1

20/-

LVH

44N

O c

asin

g - s

urfa

ce m

ount

ed o

ver o

r und

er p

enet

ratio

nFC

O17

4060

0 x

600m

mm

ax h

ole

size

500

mm

x 5

00m

mFL

6C

oncr

ete

slab

-/120

/-LV

HO

NO

ste

el s

leev

e in

pen

etra

tion

F916

8725

0mm

dia

met

erFL

7C

oncr

ete

slab

-/120

/-LV

H44

Stee

l cas

ing,

mod

ular

ban

ked

toge

ther

FCO

1963

1200

mm

x 1

200m

m

Cei

ling

CE1

FR P

l/Boa

rd 2

ply

Cei

ling

-/60/

60LV

H44

Pl/B

oard

Cla

d en

cl. (

90m

in R

ISF

inci

pien

t rat

ed)

4565

060

0 x

600m

mC

E2FR

Pl/B

oard

2 p

ly C

eilin

g-/6

0/60

LVH

44

Pl/B

oard

Cla

d en

cl. o

pen

end

(60m

in R

ISF

inci

pien

t rat

ed)

C91

474

300m

m x

300

mm

exha

ustin

g in

to c

eilin

g vo

idC

E3FR

Pl/B

oard

2 p

ly C

eilin

g-/9

0/90

LVH

-OPl

/Boa

rd P

anel

& IF

D (9

0min

RIS

F in

cipi

ent r

ated

)FP

3572

150m

m d

iam

eter

CE4

FR P

l/Boa

rd 2

ply

Cei

ling

-/90/

90LV

H-H

i-Flo

Pl/B

oard

Cla

d 3-

way

enc

losu

re (9

0min

RIS

F in

cipi

ent r

ated

)FP

3609

Inco

rpor

ates

150

mm

Hi-F

lo

Doo

rFD

1LV

H-D

in F

ireco

re fi

re d

oors

-/120

/30

LVH

-DFi

tted

to M

axi &

Min

i Fire

Doo

rsC

OT3

8860

0 x

300m

m o

r 450

x 4

50m

mFD

2LV

H-D

in P

yrop

anel

fire

doo

rs-/1

20/3

0LV

H-D

Fitte

d to

Pan

dor,

FR &

Pyr

olite

Fire

Doo

rsC

OT4

4260

0 x

600m

m, 6

00 x

300

mm

, 450

x 4

50m

mFD

3LV

H-D

in T

rafa

lgar

E-C

ore

door

s-/1

20/3

0LV

H-D

Fitte

d to

Max

i & M

ini F

ire D

oors

FCO

1211

600

x 30

0mm

or 4

50 x

450

mm

(up

to 2

off

per l

eaf)

Syst

em S

elec

tor

Intu

mesc

en

t Fi

re D

am

pers

Lori

ent

Intu

mes

cen

t Fi

re D

amp

ers

LVH

-O

Feat

ure

s•

Cos

t ef

fect

ive

solu

tion

•In

nova

tive

& e

asy

to in

stal

l lig

ht w

eigh

t de

sign

•Su

itabl

e fo

r ex

trac

t an

d su

pply

sys

tem

s in

com

mer

-ci

al, i

ndus

tria

l and

res

iden

tial p

roje

cts

•N

o ha

zard

ous

fibro

us p

acki

ng r

equi

red

•N

o th

erm

al c

lear

ance

s re

quire

d in

inst

alla

tion

•Re

duce

d m

aint

enan

ce &

res

ulta

nt c

ost

savi

ngs

•A

lso

avai

labl

e as

LV

H-O

SS f

or a

ggre

ssiv

e en

viro

nmen

ts

Tech

nic

al D

ata

•In

tegr

ity F

ire R

atin

g -

up t

o 4

hour

s•

Size

s av

aila

ble

100m

m t

o 45

0mm

Dia

•G

alva

nize

d sl

eeve

(spi

got)

360

mm

long

LVH

-O H

I FLO

Feat

ure

s•

Cle

ver

new

Hi F

lo d

esig

n w

ith s

igni

fican

tly r

educ

ed

pres

sure

dro

p•

Suita

ble

for

exha

ust

syst

ems

whe

re e

very

Pa

save

d ca

n m

ean

redu

ced

fan

sizi

ng &

res

ulta

nt p

ower

sa

ving

s•

Syst

em A

cous

tic b

enefi

ts•

No

ther

mal

cle

aran

ces

requ

ired

in in

stal

latio

n•

Redu

ced

mai

nten

ance

& r

esul

tant

cos

t sa

ving

s•

Als

o av

aila

ble

in r

ecta

ngul

ar L

VH

44 H

i Flo

des

ign

Tech

nic

al D

ata

•In

tegr

ity F

ire R

atin

g -

up t

o 2

hour

s•

Size

s av

aila

ble

150m

m &

200

mm

Dia

•G

alva

nize

d sl

eeve

(spi

got)

360

mm

long

•In

tum

esce

nt c

ell o

nly

is a

vaila

ble

LVH

-OSS

Feat

ure

s•

Cos

t ef

fect

ive

solu

tion

•St

ainl

ess

stee

l sle

eve

•N

o ha

zard

ous

fibro

us p

acki

ng r

equi

red

•Re

duce

d m

aint

enan

ce &

res

ilien

t co

st s

avin

gs•

Ava

ilabl

e w

ith H

alar

coa

ting

for

haza

rdou

s

en

viro

nmen

ts

Tech

nic

al D

ata

•In

tegr

ity F

ire R

atin

g -

up t

o 2

hour

s•

Size

s av

aila

ble

100m

m t

o 45

0mm

Dia

•St

ainl

ess

stee

l sle

eve

(spi

got)

360

mm

long

•H

alar

Coa

ting

optio

n

LVH

-D

Feat

ure

s•

Inno

vativ

e sl

imlin

e de

sign

•Su

itabl

e fo

r bo

th m

ini &

max

i fire

doo

rs•

All

in o

ne k

it in

clud

es 1

x IF

D, 2

x c

over

gril

les,

Lo

rient

Mas

tic &

fixi

ngs

•Ea

sy in

stal

latio

n in

new

or

exis

ting

door

s

Tech

nic

al D

ata

•In

tegr

ity F

ire R

atin

g -

2 ho

urs

•In

sula

tion

Fire

Rat

ing

1 /2

hour

•Si

zes

avai

labl

e 60

0 x

300m

m, 4

50 x

450

mm

& 6

00

x 60

0mm

(Pyr

opan

el d

oors

onl

y)•

Suits

35m

m a

nd 4

5mm

thi

ck F

ire D

oors

- 2

-