OWNER’S GUIDEAIR CONDITIONERINTERACTIVE
TRANE SPLIT AC
SPLIT AC WITH
REMOTEINTERACTIVE
� 486�678�
Dear Customer
WeareTRANE ,agloballeaderinheating,ventilationandairconditioningequipment.WecomefromthehouseofIngersoll Rand ,a$14billioncompanywitharoundhundredmanufacturingfacilitiesworldwide.Our1500patentsforheating,airconditioningandventilationproductsaretestimonytoourspiritofinnovation.Todaywebringinnovationtoyourhome.
At TRANE , we create products that are intuitive and easy to operate. They are simple, yettechnologically evolved for modern living. TRANE Interactive AC is one such product. TheTRANE Interactive AC assesses, manages and gives feedback on your in-home climate.Theultraslimdesignbringstogethersimplicityandelegancethatcomplementsyourhome.Onceit’sinyourhome,awholenewworldofevolvedlivingexperienceswillopenuptoyou.The‘Tranemode’optimizescomfortandefficiency.‘Efficiencymeter’ontheremotekeepsyouupdatedonenergyconsumption,andtherefore,keepsbills incheck.Theintelligentcoolingsetsthemostsuitabletemperatureforyourhomebyanalyzingthetemperatureoutside.TRANE ACcreateshomeenvironmentthatpromisesnewlevelsofcomfort,efficiencyandconvenience.
WelcometothefamilyofTRANE .
� 486�678�
Contents1. About this manual���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������4
1.1. Safety Information���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������5
1.2. Product Overview��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������10
2. Operation����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������11
2.1. Remote Operation�������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������11
2.2. Manual and Auto Restart Operation���������������������������������������������������������������������������������������������������������������������������������������������11
2.3. Indicators��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������12
2.3.1. Indoor�������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������12
2.3.2. Remote������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������12
2.4. Remote Controls�����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������13
2.4.1. Range of Operation������������������������������������������������������������������������������������������������������������������������������������������������������������������������������14
2.4.1.1. Lock and Indoor Unit range���������������������������������������������������������������������������������������������������������������������������������������������������������14
2.4.1.2. Remote and Indoor Unit range���������������������������������������������������������������������������������������������������������������������������������������������������14
2.4.2. Functions�������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������14
2.4.2.1. TRANE Mode ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������14
2.4.2.2. Cool Mode ��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������15
2.4.2.3. Dry Mode ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������15
2.4.2.4. Fan Mode�����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������15
2.4.2.5. Sleep Mode �����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������15
2.4.2.6. Turbo Mode �����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������16
2.4.2.7. Fan speed����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������16
2.4.2.8. Night latch Mode (Only for units with “TRANE Lock”)�����������������������������������������������������������������������������������������������������������16
2.4.2.9. Multi Room ������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������16
2.4.2.10. Swing Control������������������������������������������������������������������������������������������������������������������������������������������������������������������������������17
2.4.2.11. Power ON and OFF����������������������������������������������������������������������������������������������������������������������������������������������������������������������17
2.4.3. Replacement of Batteries�������������������������������������������������������������������������������������������������������������������������������������������������������������������17
2.5. Stabilizer Detail������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������17
3. Maintenance���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������18
3.1. Cleaning air filter���������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������18
3.2. Maintenance (Unit not in use for long duration)�������������������������������������������������������������������������������������������������������������������19
3.3. Checks before operation�����������������������������������������������������������������������������������������������������������������������������������������������������������������������19
4. Troubleshooting�����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������20
4.1. Error Messages and Actions����������������������������������������������������������������������������������������������������������������������������������������������������������������21
Warranty������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������23
4 486�678�
Contents
1. About this manualThis manual is given as a guide to good practice for operating and periodic maintenance of TRANE AirConditioners.
Thisdoesnotcontainthefullservicingproceduresnecessaryforcontinued,orsuccessfuloperationofthisequipment.Theservicesofaqualifiedservicepersonnelmustbeemployed,throughmediumofmaintenancecontractwithaTRANEservicecompany.
Donotoperatebeforereadingmanual(s)suppliedwiththisproduct.
Cautionsasapplicableareshowninthismanual.Personalsafetyandproperoperationofthisunitrequirethatyoufollowthemcarefully.Themanufacturerassumesnoliabilityforinstallationsorservicingperformedbyunauthorisedpersonnel.Alwaysinstall,operate,inspectandmaintainthisproductinaccordancewithallapplicablestandardsandregulations(local,state,country,federal,etc.).Keepthisusermanualcarefullyforfuturereference.
5 486�678�
Contents
1.1. Safety Information
Indicatesapotentiallyhazardoussituationwhich,ifnotavoided,couldresultinseriousinjury.
Indicatesapotentiallyhazardoussituationwhich, ifnotavoided,mayresult inminorormoderateinjuryorpropertydamage.
Obey the following points to prevent electrical shock or fire:
Don’ts
Do not remove power plug while the unit is in operation. Itcancauseanelectricalshockorfire.
•
Do not operate this unit with wet hands. It can cause anelectricalshock.
•
Do not pull power cord to remove power plug. It can causefire.
•
Do not use longer power cord and/or share a same socket with other electrical appliances.Itcancauseelectricalshockorfire.
•
6 486�678�
Contents
Do not place flammable spray near this unit. It can causeignitionandexplosion.
•
Do not insert or stick your hands into air intake or outlet vents. Itisdangerousandcancauseinjury.
•
Do not spray or wash the unit with water. Itcancauseelectricalshockand/ormalfunctionofunit.
•
Do not splash water on the unit.Itcancauseanelectricalshockand/ormalfunction.
•
Do not open windows and/or doors for long duration when unit is ‘ON’. Thiswilldecreasethecoolingperformance.
•
Do not splice power cord or use an extension cord.Itcancausefireorshortcircuit.
•
7 486�678�
Contents
Do not insert any objects or fingers into the outdoor unit fan. Itmaycauseunitfailureand/orseriousinjurytotheperson.
Do not touch the fins at the back side of outdoor unit. Itcancauseinjury.
•
•
Do not step on top of outdoor unit. Fallingoffoutdoorunitcancauseinjury.
•
Do’s
Make sure that all power supply connections are tight. Check whether electrical grounding (earth) is complete.Ifnotdone,itcancauseelectricalshockorfire.
•
Turn off the power supply and pull out power connection before cleaning.Ifnotdone,itcancauseelectricalshock.
ChemicalagentssuchasGasoline,benzene,thinnerinsecticidesetc.,candamagethisunit.
•
•
Make sure installation stand is sufficiently firm. An unstablestandcancausephysicalinjurytothepersonordamage theunit.
•
8 486�678�
Contents
Operate this unit with stable voltage in range of 230 ± 10%, single phase. Ifnotdone,compressorcanvibrateanddamagerefrigerationsystem.
•
Use only fuse of correct capacity. Incorrect wire can causebreakdownorfire.
•
Turn offthe power
supplyIf you detect burning smell or smoke, turn off power supply and contact customer care centre immediately.
•
Don’ts
Do not try to repair this unit. Itcancausedamage.•
Do not block air intake or outlet vents of both outdoor and indoor units. Itcandecreasetheperformanceoftheunitorcausemalfunction.
•
� 486�678�
Contents
m
e
Do not keep remote on any metals, electronic or heating devices like oven, TV, etc. for a longer period. Itmaydecreasethelifeofremote.
•
Do not expose your body to cold air for a long duration. It can cause deterioration in physical condition and healthproblems.
•
Do not use water at a temperature above 45 °C to clean, it can deform or discolour front panel.
Do not dry filters near fire. Itcanigniteordeformthem.
Do not drop or throw remote control. Itcancausemalfunctioningorbreakage.
Do not use remote under direct sun light.Itcancreatedisplayissues.
•
•
•
•
Do’s
Run in the Green Zone
e
Set the unit at TRANE mode for efficient performance. Itwillsaveenergy.
•
It is suggested to use TRANE recommended stabilizer. For stabilizers check with local TRANEdistributor.
•
10 486�678�
Contents
1.2. Product Overview
8. Connecting pipe 9. Connecting cable10. Sensor cable11. Stop valve
Outdoor unit
Outdoor unit
1. Front panel 2. Air inlet 3. Air filter 4. Air outlet 5. Horizontal air flow grille 6. LED display 7. Remote control
Indoor unit
Indoor unit
11
9
10
8
7
4 5
21 3 6
e
Figure - 1
11 486�678�
Contents
2. Operation
2.1. Remote OperationMakesurepowerisON
Selecttheroomwhichneedstobecontrolled.
Refersection�.4.�fordifferentfunctionsofremote.
2.2. Manual and Auto Restart OperationManualoperationcanbeusedtemporarilyincaseremotecontrollerisnotavailable.
LiftFrontpaneluptoanangle, keepingitattached untilitmakesaclicking sound (Refer Figure -�).
Donotliftfrontpanelatanangleabove60degrees.Donotapplytoomuchforce.
Figure - 2
Whenyoupressmanual control button (Figure-�),theunitisswitchedonatthefollowingdefaultconditions
MODE:COOL FANSPEED:MEDIUM SWING:AUTO SETTEMP:�4°C
Lowerthefrontpaneltoitsinitialposition.
Manual control button Figure - 3
Useobjectnotmorethan5mmindiametertopressmanualcontrolbutton.
Torestoreremotecontroloperation,useremotecontroldirectly.
TheDisplayLEDstatuswillnotchangewhenunitisoperatedthroughmanualcontrolbutton.
•
•
•
Auto Restart FunctionPowercutduringoperationwillstoptheunitcompletely.
Unitstartsautomaticallywithallprevioussettingssavedinmemoryfunctionwhenthepowerisrestored.
Remotewillbeinsleepconditionafter�0secondfromlastkeypressed.RemotewakesupfromsleepconditiononfirstkeypressedanddoesnotsendscommandtoACunitandupdatejustthedisplaysettings.
•
•
•
•
•
•
•
•
1� 486�678�
Contents
2.3. Indicators
2.3.1. IndoorLED 2LED 1
Figure - 4
LED Indication
Unit status LED1 LED2
Standby OFF OFF
Standby+ErroronPCB OFF RED
OperatingwithoutTRANEmode GREEN OFF
OperatingwithoutTRANEmodeandErroronPCB GREEN RED
TRANEmodeactive GREEN GREEN
TRANEmodeactive+ErroronPCB GREEN GREENandREDBlinksalternately
Buttonpressonremote GREENblinkonce Nochange
Sound Indication
Unit status Buzzer
UnitpoweredON–instandbystate
(MainsPowerON)
Oneshortbeep
UnitpoweredON–inoperatingstate
(MainsPowerON)
Oneshortbeep
UnitpoweredOFF(standby)/ONusingremote Onelongbeep
Buttonpressonremote Oneshortbeep
2.3.2. Remote
User Mode Trane Mode
e e
Figure - 5
1� 486�678�
Contents
2.4. Remote Controls
e
Room Temperature
Fan Speed
Set Temperature
Room Selection
Fan Speed
Louver Direction
Sleep/Turbo Mode
Remote Night Latch Multi Room Control
Acvtivated Night Latch
Mode Indication
Outdoor Temperature
Error Message Display
Increase Temperature
Decrease Temperature
Mode Adjustment
Energy Efficiency Meter
Power ON/OFF
TRANE Mode
Sleep/Turbo Mode
Figure - 6
Symbol Button Function Display Description
Fanspeedadjustment Airflowrateadjustment. Showsfanspeed
Swingadjustment
Changestheairflowdirection NA* Changestheairflow
direction
SLEEP/TURBOmodeactivation
TogglesbetweenSLEEP,TURBOandDefault. / Showsmodeselection
(SLEEP/TURBO)
TemperatureUP/DOWN
Increase and decrease thesettemperature
Showstemperatureselection
14 486�678�
Contents
Symbol Button Function Display Description
ModeAdjustment
Changes the mode as such,press once for COOL, twiceforDRYandthriceforFAN.
/ / Showsmodeselection(COOL/DRY/FAN)
TRANEMode ActivatesTRANEmode ReferFigure-5 ActivatesTRANEmode
Power ON/OFF NA* ON/OFF
Nightlatchmodeactivation/deactivation
Activates/deactivatesnightlatchmodeonTRANElock.
Showsnightlatchmodeselection
Multiroom(RoomConfiguration)
Selectsthesplitairconditionertocontrol.
ShowsroomselectionasforeachroomACsettings
- NA* - Indicateserror
- NA* -e
Showsdifferentefficiencyzone(Refersection�.4.�.�)
- NA* - Showscurrentoutdoorambienttemperature.
- NA* - Showscurrentroomtemperature.
*NA:NotApplicable
2.4.1. Range of Operation2.4.1.1. Lock and Indoor Unit range
Range (Indoor) Range (Outdoor - without any obstacles)
15meter 1000meter
2.4.1.2. Remote and Indoor Unit range
Range (Indoor) Range (Outdoor - without any obstacles)
14meter 160to175meter
2.4.2. Functions2.4.2.1. TRANE Mode
Press tostartorstopTRANEmode(ReferFigure-7).
TheunitwhenpoweredONbyremotecontrolstartswithTRANEmodebydefault.
TheTRANEmodewillsetroomtemperatureandfanspeedautomaticallytoprovidean energy efficient and comfortable environment hence the energy efficiencymeteralwaysshowsdarkgreen(ReferFigure-5)
Itwillsetroomtemperatureautomaticallybasedonoutdoortemperature.
Unitshallexit‘TRANEmode’ifuserchangesanyofthefollowing:setpoint,fanspeed,mode,andalsoif buttonispressed.
1.
�.
�.
4.
5.
Figure - 7Figure - 7
15 486�678�
Contents
Unitwillnotexit‘TRANEmode’ifuserchangesanyofthefollowing:swingbutton, multiroomor nightlatchbutton.
TheindicationofTRANEmodeis buttonwithredbacklightandtheremainingbuttonswithlightOFF.ThebacklightwillgoOFFafter�0secondsfromlastoperationofremotecontroller.
2.4.2.2. Cool Mode
Figure - 8
COOL
DRY
FAN
e
1 2 3
Display
PressMODE toselectcoolmode,see‘COOL’shownondisplay(ReferFigure-8).
Press tosetfanspeed(ifrequired)
Press or toincreaseordecreasesettemp.Settemperaturerangeis17°C-�0°C.
Thisisnormalmodeofcooling.UsercansetroomtemperatureandACwillruntoattainthesettemperature.
Temperaturecanbesetbasedonenergyconsumption,Referbelowtable
Zone1-Red Uneconomical
Zone�-Yellow Higherenergyconsumption
Zone�-Lightgreen Economical
Zone4-Darkgreen Lowerenergyconsumption
2.4.2.3. Dry Mode
PressMODE toselectdrymode,see‘DRY’shownondisplay(ReferFigure-10).
Indrymodedefaultsettemperatureis�5°C.
Settemperatureandfanspeedcannotbechanged.
Unitwilloperateatlowfanspeedformaximummoistureremoval.
Inhighhumidityconditions,usercanselectdrymode.
2.4.2.4. Fan Mode
PressMODE toselectfanmode,see‘FAN’shownondisplay.
Setpointtemperaturecannotbeadjustable.Fanspeedcanbeadjustable.
2.4.2.5. Sleep Mode
Press toactivatesleepmodeoperation.
The‘set’ temperature will automatically increase by 1°C for eachhourforfourhours.After 4 hours unit will stay at latest temperature. E.g., if thesettemperatureis�4°Candsleepmodeisstarted.Afterfirsthoursettemperaturewillincreaseto�5°Candattheendoffourthhoursettemperaturewillbeat�8°C.Theunitwillstayat�8°C.Press againtodisablesleepmode.Setpointtemperatureandfanspeedcanbeadjustable.
6.
7.
1.
�.
�.
1.
1.
1.
eFigure - 9
1
2 3
4
eFigure - 9
1
2 3
4
e
Display
Figure - 10
1
e
Display
Figure - 10
1
1
e
Display
Figure - 11
1
e
Display
Figure - 11
1
Display
Figure - 12
e
1
Display
Figure - 12
e
16 486�678�
Contents
2.4.2.6. Turbo Mode Press toactivateturbomode.See‘TURBO’onremotedisplay.
Enablesinstantcoolingbyautomaticallyadjustingfanspeedtoturbolevel.
Fanspeedcannotbechangedwhileunitisinturbomode.Thedisplaywillnotshowthefanspeedbar(ReferFigure-1�).
Usercansetthismodeforfastcooling.Press againtodisableturbomode.
2.4.2.7. Fan speed
Pressfanspeed tochangefanspeed.
Fanspeedcanbechangedasbelow
Low Medium High Auto
FanspeedisadjustedautomaticallyaccordingtosetpointandroomtemperaturewhenFANspeedissettoAUTOmode.
2.4.2.8. Night latch Mode (Only for units with “TRANE Lock”)
LOCK
Night latch Mode Ac�va�on
AC Remote
e
Display
Figure - 15
Press onremotetoactivateordeactivatenightlatchmodeonlock.Nightlatch willshowonremotedisplayafteritstarts (approximately�0 seconds for display to update).Nightlatchmodehelpsusertopreventaccesstohomeevenwithvalidcredential.NightlatchmodeoperatesonlywhenLockandACareconnectedonnetwork.Referlockmanualfornightlatchmodefeatures.
Whennightlatchisactivated, andtheconfirmationmessage“NIGHTLATCHENABLED”willbedisplayed.Ifitisnot,therewillbenodisplayindication(ReferFigure-15).
2.4.2.9. Multi Room
Press toactivatemultiroomfeature.
MultiroomfeatureallowusertoselectandcontroltwoormoreAC’swithoneremotefromoneroom.
Press toswitchandcontrolACinnetwork.
NameofselectedACanditscurrentsettingsshownonremotedisplay.
1.
1.
1.
�.
�.
1.
1
Display
Figure - 13
e
1
Display
Figure - 13
e
Display
Figure - 14
e
1
Display
Figure - 14
e
1
Display
Figure - 16
e
1
Display
Figure - 16
e
1
17 486�678�
Contents
2.4.2.10. Swing Control
Deflector rod Figure - 17
Useswing toadjustairflowdirection.Thehorizontallouverchangesdirectionatdefinedangleandautoswing.Verticallouvercanonlybeadjustedmanually.Movedeflectorrodmanuallytoadjustairflowdirection.
Adjustairflowdirectionproperlyotherwiseitcancausediscomfortorunevenroomtemperatures.
2.4.2.11. Power ON and OFF
PressON/OFFbuttontoswitchON/OFFtheunit.WhenpowerisON,theunitoperateinTRANEmodebydefault.
Remotebacklightwillglowinred .
2.4.3. Replacement of Batteries
Donotusecombinationofoldandnewbatteries.Lifeofbatteryismorethansixmonthsinnormalusage.
To prevent batteries from leakage of electrolyte and damaging controller, remove the batteries,ifnotinuse for long duration.
Batteriesaretobereplacedwhen“LowBattery”errorisshownondisplay.
•
•
•
ToReplaceBatteries, • Slidebackcoverandremoveoldbatteries. • UsetwonewAAAalkalinebatteries(Recommended:Duracell®#‘AAA’batteriesrated1.5V) • BatteryPolesmustalignwithinstallationposition(ReferFigure-18)
1 2 3
Figure - 18
2.5. Stabilizer Detail
ACTonnage StabilizerKVA
1.0 �
1.5 4
� 5
1.
�.
1.
�.
•
#RegisteredtrademarkofDuracell,P&GInc.#RegisteredtrademarkofDuracell,P&GInc.
18 486�678�
Contents
3. Maintenance
3.1. Cleaning air filterCloggedairfilterdecreasescoolingefficiency.Cleanfilteratintervaloftwoweeks.
Disconnectpowersupplybeforecleaningindoorunit.
Support pole1
LiftFrontpaneluptoanangle,keepingitattacheduntilitmakesaclickingsound.
Cleanunitswithsoft,dryormoistclothwithwaterorcleanser.
Usesupportpoletoholdthefrontpanelatitsplaceafterliftingit.
•
•
•
Filter Handle
2
Holdtheairfilterhandleandliftslightlytoreleaseitfromholder,pulldownwardstoremoveairfilterfromindoorunit.
•
3Cleanairfilterwithavacuumcleanerorwater,dryincoolplace.
•
Air freshening filter
4Removeairfresheningfiltersfromitssupportingframe. Clean air freshening filter monthly, andreplaceatanintervalof4-5months.
Install air freshening filter into its originalposition.
•
•
5 Insertupperpartofairfilterandplacefilter intoposition, make sure left and right edges aligncorrectly.
•
1� 486�678�
Contents
3.2. Maintenance (Unit not in use for long duration)Ifyoudonotplantouseunitforalongtime,performfollowingactions:
Cleanindoorunitandfilters.
Operatefanforapproximately�0minutesinordertodryinnersideofunit.
SwitchOFFtheunit.
The outdoor unit requires periodic maintenance and cleaning. The user must not do periodicmaintenanceofproductontheirown.Contactdealerorserviceprovider.
3.3. Checks before operationMakesurewiringisnotbrokenordisconnected.
Makesureairfilterandfrontpanelareinstalled.
Makesureairoutletorinletisnotblocked.
Ifairfilterscreenisblockedbydustordirt,theperformanceoftheunitwillbeaffected,withhigheroperationnoiseandpowerconsumption.Airfilterscreenshouldbecleanedregularly.
Preparation before season of use1.Be sure that nothing obstructs air outlet and intake vents.
(ReferFigure-1�)
�.Examinewhetherground(earth)wireiscorrectlyconnected.
�.Replacefiltersifnecessary.
4.Replacebatteriesofremoteifnecessary.
5.Examinemountingbracketofoutdoorunit,ifdamagedcontactservicingagency. Figure - 19
Ground wiringConnect Ground wire to exclusive device correctly, if not employ specialist to install. Grounding pole ofsocket shouldbegroundedandwired reliably,breakerandair switch withenough capability shouldbeinstalledinfixedlines.Donotconnectgroundingcabletogaspipe,waterpipe,sewagepipeoranyotherareasdeemedunreliableforthispurpose.
•
•
•
•
•
•
•
�0 486�678�
Contents
4. TroubleshootingBefore requesting service, perform following checks.
Symptom Remedy
WaitingIndoorunitdoesnotgivecoolair immediately when unitstarts.
Compressor restarts after approximatelythree minutes to protect itself. Oncompressor restarting units starts to givecoolairagain
Unusual odor blowing fromoutletwhenunitisstarted.
Open the door or window for � minutesandruntheACinFanmodetoallowfreshair inside the room.This helps to removeodorsfrom the room.
Sound of water flow duringoperation.
Thisiscausedbyrefrigerantflowinginsidetheunit.
Formation of mist whilecooling.
Roomairiscooledquicklybycoldairflowwhichlookslikefog.
Creakingnoiseduringstartorstop.
Deformation of plastic because oftemperaturechange.
Unitdoesnotoperate.
Checkelectricalsystemconnections,cordsandfuses.Check if power supply is within 10% ofratedsupply.
Decreasedcoolingefficiency.
Check‘settemperature’.Check for obstructions in air inlet andoutlet.Checkairfiltersfordirt.Checkindoorfanspeed.Checkanyotheropeningsintheroom.
Remotecontroldoesnotworkcorrectly.
Checkeffectivedistancetoindoorunit.
Check low battery error indication onremotedisplay.
Ifthetroublehasnotbeencorrected,pleasecontactalocaldealerorthenearestcustomerservicecentre.Besuretoinformthemofthedetailsof malfunctions and unit model number.
Donotattempttorepairtheunityourself.Alwaysconsultanauthorizedserviceprovider
�1 486�678�
Contents
4.1. Error Messages and Actions
Error Code Error Description Error Displayed on
Remote Unit Response Action to be taken by user
0x01 EEPROMERRORERROR 01 EEPROMcommunication errorcontactservicetechnician
Unit stopsworking
Contact servicetechnician
0x0�COMPRESSOR FAILUREERROR OR RefrigerantLeakageError
Error 0� Compressorfailure or refrigerantleakage contact servicetechnician
0x0� FILTERCHOKEERROR Error0�Filterchokeerror-Cleanthefilter
Unit operates asperusersettings Cleanfilters
0x04 INDOOR TEMP SENSORERROR(Room)
Error 04 Room tempsensor failure contactservicetechnician
Cool mode or Dry mode: Unitoperate withCompressorOFF
Fan mode: Operates as perusersetting
Contact servicetechnician
0x05 OUTDOOR TEMP SENSORERROR
Error 05 outdoor tempsensor failure contactservicetechnician
Operates indoorunit and outdoorunit as per usersetting. If TRANEmode is activatedunit shouldoperate at setpoint�4°C.
0x06 INDOOR COIL SENSORERROR
Error 06 Indoor tempsensor failure contactservicetechnician
Cool mode or Dry mode: Unitoperate withCompressorOFF
Fan mode: Operates as perusersetting
Contact servicetechnician
0x08 COMMUNICATIONERRORError 08 Communicationerror contact servicetechnician
Stop indoor unitandoutdoorunit
0x0� BATTERYLOWERROR Error 0� Low batterypleasechangethebattery
Operates indoorunit and outdoorunit as per usersetting.
Changebattery
0x0A INPUTPOWERERROR ERROR 10 IDU ERROR-INPUTPOWERPROBLEM Unit stops
working
Check the powercord / Contactservicetechnician
0x0B FANFAILUREERROR ERROR 11 IDU ERROR-FANFAILURE
Contact servicetechnician
�� 486�678�
Contents
Error Code Error Description Error Displayed on
Remote Unit Response Action to be taken by user
- Remote not in networkrange NETWORKNOTFOUND
Unit operatesas per previoussettings.
Remotemustbeinnetworkrange
-Connect to network (ifuser did factory reset ontheremote)
CONNECTTONETWORKUnit operatesas per previoussettings
Contact servicetechnician
- AC switched OFF (mainpowerOFF)
SET POINT TEMP +INFRARED ACTIVATED +NONETWORKFOUND
Switch ON mainpower/check theplug
Lock with AC
- Locknotinstalled NIGHT LATCH FAILED --LOCKNOTINSTALLED
Lock is not innetwork
- NightlatchnotoperatingNIGHT LATCH FAILED --PLEASE CHECK YOURLOCK
Change Batteryof Lock or CheckLockisinNetworkby doing Home/AwayOperations
- DoorOpen NIGHT LATCH FAILED --DOOROPEN Closedoor
ReferSection�.�.1forLEDindications
�� 486�678�
Contents
Warranty
Terms & ConditionsIngersoll-Rand(hereinafterreferredtoas‘thecompany’)warrantstothepurchaserthatthisTRANE split air conditioner(“Product”)carriesawarrantyfortheperiodmentionedabove,commencingfromthedateofpurchase.ThecompanywillrepairorreplacefreeofchargeanypartorpartsoftheProduct,ifthedefectisduetothedefectivematerialorworkmanship.Warrantyinvolvesrepairingofdefectiveproduct/partsanddoesnotentitlethepurchaserforthereplacementforanewproduct.
Preventive Maintenance:Maintenancecheckupwillbecarriedout� times inaperiodof1�months fromthedateof invoiceonrequest fromthecustomerandwillinclude:
Generalcleaningandbrushingupofdirtandmuck.Cleaningofairfilter.Checkingofelectronicpartsanditscontacts.
Breakdown ComplaintsCompany will put in reasonable efforts to promptly attend to any breakdown complaint lodged by the customer at company’sauthorizedsalesandservicedealerorbranchofficeoratthecentralizedcustomercarecentre.
Compressor Warranty Clause:The 5 year compressor warranty will continue even after the expiry of 1 year period from the date of purchase. This warranty covers thecompressoronly.Gaschargingisincludedonlywhenthecompressorisdefective&inoperative.Duringtheadditionalwarrantyperioditdoesnotcoverpartsoranypartsuchas
CondenserCoilEvaporatorCoilCapillarySuctionLineElectronicParts
Other termsThiswarrantyisconfinedtothefirstPurchaseroftheProductonly&isnontransferable.
ThewarrantyforbothmachineandcompressorwillterminateuponexpiryofthewarrantyperiodirrespectiveofwhetherornottheProducthasbeeninuseforanyreasonwhatsoever.
ThewarrantyforbothProductandthecompressorwillautomaticallybeterminatedonthedateofexpiryofthewarrantyperiod.Nonoticeofexpiryofwarrantywillbegivenatanytime.
CompressorwarrantywillbeapplicableonlyiftheProductismaintainedbyauthorizeddealersofthecompany.
For Products installed beyond the municipal limits of the jurisdiction of the authorized service centre/company’s service centre/authorized dealer’s service centre, all expenses incurred in collection of the Product or part/s thereof from the company’s servicecentre/authorizedservicecentre/authorizeddealer’sservicecentre,aswellasexpensesincurredinconnectionwithdeputingofservicepersonnel/technicianstowardstoandfrotravel,conveyanceandother incidentalsetc. (togetherreferredtoas“TransportationandHandlingExpenses”)shallbebornebythePurchaser.
ThecompanyortheauthorizedsalesandservicedealerwilladvisethePurchaserwhethertoeffectrepairs/replacementatthesiteofinstallationoratthecompanyorauthorizedsalesandservicedealer’spremisesandthedecisionoftherepresentativeshallbefinal.
ThecompanyreservestherighttoreplacethedefectivepartwithasubstituteequivalentpartwithoutaffectingtheperformanceoftheProduct.
Incaseofanytransitdamage,theProductshallberepairedbytheconcernedservicecentreonchargesandwarrantyfortheunexpiredperiodwillcontinue.
In theeventof repairs/replacementofanypart/sof theProduct, thiswarrantywill thereaftercontinueandremain in forceonly fortheunexpiredperiodofthewarranty.Moreover,thetimetakenforrepair/replacementandintransitwhetherunderthewarrantyorotherwiseshallnotbeexcludedfromthewarrantyperiod.
Thewarrantyextendedhereinisinlieuofimpliedconditionsandwarrantsunderthelaw&isconfinedtotherepairorreplacementofdefectivepartsanddoesnotcoveranyconsequentialorresultingliability,damageorlossarisingfromsuchdefects.Also,thewarrantyinnocaseshallextendtopaymentofanymonetaryconsiderationwhatsoeverorreplacementorreturnoftheProductasawhole.
Thecompany’sobligationunderthiswarrantyshallbelimitedtorepairorprovidingreplacementofpart/sonly.Themaximumclaim/sifentertainedbythecompanywillbesubjecttothemaximumretailpriceoftheProductpurchasedorthepurchaseprice,whicheverislower.
AnychangeofAddressofthepurchaserwillbeintimatedtotheconcernedservicecentre/dealerforcontinuationofwarranty.
Thecompanyshallnotbeliableordeemedtobeindefaultforanydelayorfailureinperformanceresultingdirectlyorindirectlyfromcauses beyond its reasonable control including delay in repairing due to non-availability of any part/component, labour problem,presenceofanyforeignobjectorlivingcreature(e.g.Rat,lizard,Insects,Antsetc.)insidetheunit,useofharmfulchemicals,usageofunitinanabnormallycorrosivealkaline/acidicatmosphere,restrictionsandregulationsoftheGovt.,publicmovement,warandanyotherunavoidablecircumstancesvis-a-vistheimportofsuppliesandrawmaterialorifthecompanyisotherwisepreventedfromperformingitsfunctionsunderthiswarranty.
•••
•
•••••
1.�.
�.
4.5.
6.
7.
8.
�.
10.
11.
1�.1�.
�4 486�678�
Contents
While the company undertakes responsibility to supply only the compressor free of cost during warranty period, cost of labour,transportationandotherincidentalexpendituresshallbebornebythecustomerafterthelapseoffirstyearProductwarranty.
Inareaswherevoltagefluctuates+/-10%ofratedorusablevoltage,customerisadvisedtouseabrandedvoltagestabilizerwhichstepsupordowntheincomingvoltagetogiveanoutputof��0V.Foranyfluctuationbeyondthereasonablespecifiedlimit,thecompanyshallnotberesponsibleandthiswarrantyshallimmediatelystandterminated.
Earthingprovisionisnecessaryforsafety.Improperdomesticwiringleadingtohazardssuchasshockorfireisnotcoveredunderthiswarranty.
WhiletheCompanywillmakeeveryefforttocarryouttherepairsattheearliest,ithoweverismadeexpresslyclearthatthecompanyisundernoobligationtodosoinaspecifiedperiodoftime.
Anyspecial,indirectorconsequentialpropertyorcommercialdamageofanynaturewhatsoeverisnotcoveredunderthiswarranty.
ThewarrantyisissuedatBangalore,andCourtsatBangaloreshallhaveexclusivejurisdictionovermatterscoveredorflowingfromthiswarranty.
Warranty is null and void in the following cases:Warranty
card
is
not
duly
filled
and
mailed
back
to
the
service
centre
for
registering
the
Product
within
three
months
of
purchase.
Complete
warranty
card
is
not
presented
to
authorized
personnel
at
the
time
of
repair.
Product
is
not
used
according
to
the
instructions
given
in
the
user
manual.
Original
serial
number
is
removed/tampered
with.
Modification
or
alteration
of
any
nature
whatsoever
is
made
in
the
electrical
circuit/physical
construction
of/to
the
Product.
Installation/repair
work
carried
out
by
person/agency
other
than
authorized
agency.
Site
conditions
that
do
not
confirm
to
the
recommended
operating
conditions
of
machine.
14.
15.
16.
17.
18.1�.
1.�.�.4.5.6.7.
For any product related assistance, please call on Toll free number: 1800 102 9986.
The1yearwarrantyisapplicabletoallpartsexceptforPlastic&Rubberparts.�0.
Corporate Office: Plot No.35, KIADB Industrial Area, Bidadi
Bangalore - 562109. www.traneindia.com
For more information call on 1800 102 9986 or write to [email protected] | Edition 1 | June 2012