4
INTELLIGENT PLASMA EMISSION DETECTOR SYSTEM FOR GAS CHROMATOGRAPH This microprocessor based plasma emission detector system gives all the tools to the GC integrator, manufacturer and user to integrate a plug and play detection system. With its customable coniguration capability, a detector has never been so intelligent. IN A GLANCE: • Argon or helium carrier gas • No dead volume design • All in one detector by replacing existing technologies commonly used • Selective and non-selective coniguration • Analog or digital interface • Wide range of applications • Easy to interface with any GC and analyzer design • PPB to % detection • Very stable signal • Maintenance free • Fast installation and tune up • Coniguration software • Possibility of customable protocol to control the device • Detect organic and inorganic compounds, permanent gases and noble gases (including Ne) Patented www.ldetek.com Where innovation leads to success

INTELLIGENT PLASMA EMISSION DETECTOR SYSTEM FOR GAS …€¦ · IN A GLANCE: • Argon or helium carrier gas • No dead volume design • All in one detector by replacing existing

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: INTELLIGENT PLASMA EMISSION DETECTOR SYSTEM FOR GAS …€¦ · IN A GLANCE: • Argon or helium carrier gas • No dead volume design • All in one detector by replacing existing

INTELLIGENT PLASMA EMISSION DETECTOR SYSTEM

FOR GAS CHROMATOGRAPH

This microprocessor based plasma emission detector system gives all the tools to the GC integrator,

manufacturer and user to integrate a plug and play detection system. With its customable coniguration capability, a detector has never been so intelligent.

IN A GLANCE:

• Argon or helium carrier gas• No dead volume design• All in one detector by replacing existing technologies commonly used

• Selective and non-selective coniguration• Analog or digital interface• Wide range of applications• Easy to interface with any GC and analyzer design

• PPB to % detection• Very stable signal• Maintenance free• Fast installation and tune up • Coniguration software• Possibility of customable protocol to control the device • Detect organic and inorganic compounds, permanent gases and noble gases (including Ne)

Patented

www.ldetek.com Where innovation leads to success

Page 2: INTELLIGENT PLASMA EMISSION DETECTOR SYSTEM FOR GAS …€¦ · IN A GLANCE: • Argon or helium carrier gas • No dead volume design • All in one detector by replacing existing

DOPING AGENT INJECTOR TEMPERATURE CONTROLLED

By controlling the temperature of the doping agent injection device, better stability of the measurement is achieved. The

temperature is controlled by the PlasmaDetek controller and can be adjusted for the speciic application. The use of different doping agents is application dependant is part

of the selectivity mode.

SELECTIVE AND NON-SELECTIVE

CONFIGURATION

The selectivity mode simpliies the chromatography and can be conigured for speciic application.

100ppm O2 & 10ppm N2 in He

O2

O2N2

12ppm N2 in balance Oxygen

O2

N2

N2

100ppm O2 & 10ppm N2 in He 12ppm N2 in balance Oxygen

Conventional ionization detector

Plasmadetek

PED DESIGN WITH NO DEAD VOLUME

The PlasmaDetek design avoids the creation of phantom peaks that occurs in conventional ionization detector. Its unique design made of a monolitic quartz makes the detector dead volume free. It is not affected by pressure or low swings.

CARRIER

GAS

GENERATOR

HIGH INTENSITY

HIGH FREQUENCY

LIGHT EMISSION

Where innovation leads to success www.ldetek.com

2

Page 3: INTELLIGENT PLASMA EMISSION DETECTOR SYSTEM FOR GAS …€¦ · IN A GLANCE: • Argon or helium carrier gas • No dead volume design • All in one detector by replacing existing

MICROPROCESSOR BASED CONTROLLER

With an integrated DSP, the signal can be processed to improve measurement as well as providing desired signal for any GC. Conigurable with LDetek plasma conigurator provided with each PlasmaDetek. Cost saving by having no electrometer needed to acquire the signal. Multiple stage of ampliication integrated to achieve low to high concentration.

ETHERNET PORT

Connect the PlasmaDetek to your network to communicate with the device.

2 ANALOG OUTPUTS

AS STANDARD

Both analog output can be used in parallel to interface with the desired signal acquisition system. Coaxial cables are provided with detector.

SERIAL INTERFACE

USB and RS-232 connection are available to provide digital signal and avoid analog

interface. Custom digital communication can

also be implemented to communicate and

conigure the PlasmaDetek from your own system.

www.ldetek.com Where innovation leads to success

3

Page 4: INTELLIGENT PLASMA EMISSION DETECTOR SYSTEM FOR GAS …€¦ · IN A GLANCE: • Argon or helium carrier gas • No dead volume design • All in one detector by replacing existing

JCT Analysentechnik GmbH Werner Heisenberg-Straße 4 A-2700 Wiener Neustadt

Tel. +43 (0) 2622 / 87201 Fax +43 (0) 2622 / 872011

E-Mail: [email protected] Web: www.jct.at

SPECIFICATIONS:

CARRIER GAS

POWER

GAS CONNECTIONS

OPERATION OUTLET PRESSURE

OPERATING TEMPERATURE

FILTER

DETECTOR SIGNAL OUTPUT CONNECTION

POWER CONSUMPTION

PLASMADETEK CONFIGURATOR:

SIGNAL POLARITY:

FILTERING:

GAIN:

OUTPUT VOLTAGE:

ZERO BASELINE:

Connect up to 8 detector to the same plasma controller.

DIAGNOSTIC TOOL:

PEAK TABLE:

1

1

98

7

10

2 3 4 3

2

3

4

5

6

7