80

INSTRUMENTS EARTH RESISTANCE · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

Embed Size (px)

Citation preview

Page 1: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)
Page 2: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

INSTRUMENTS

DIGITAL MULTIMETERS

- Selection Guide ................................................................................................... 10-11

- Multimeters ......................................................................................................... 12-18

- Accessories ............................................................................................................... 19

CLAMP METERS

- Selection Guide ................................................................................................... 20-21

- Clamp Meters ...................................................................................................... 22-29

EARTH RESISTANCE TESTERS

- Selection Guide ........................................................................................................ 30

- Earth Resistance Testers ....................................................................................... 31-32

- Compliance Kits ........................................................................................................ 33

INSULATION TESTERS

- Selection Guide ................................................................................................... 34-35

- Insulation Testers ................................................................................................. 36-40

- PSC Loop Testers ....................................................................................................... 41

- ELCB/Polarity/Phase Rotation Testers .................................................................... 42-47

- Miscellaneous and Voltage Testers ....................................................................... 47-51

- Surge Protection ....................................................................................................... 48

COMPLIANCE TESTERS

- Selection Guide ........................................................................................................ 52

- Compliance Testers ................................................................................................... 53

POWER ANALYSERS

- Selection Guide ........................................................................................................ 54

- Power Analysers ....................................................................................................... 55

- Accessories ............................................................................................................... 56

PHOTOVOLTAIC INSTRUMENTS

- Selection Guide ................................................................................................... 57-58

- Solutions for Performance and Troubleshooting ........................................................ 58

- Selection Guide - Accessories ............................................................................... 59-60

- Photovoltaic Instruments ...................................................................................... 61-62

- Calibrators ................................................................................................................ 63

- Test Leads ............................................................................................................ 64-66

- Cable Avoidance Detectors ....................................................................................... 67

- Cable Route Tracers .................................................................................................. 68

- High Voltage Testers ............................................................................................ 69-72

- Automotive Testers .............................................................................................. 73-74

- Tachometer testers .................................................................................................... 75

- Digital Timers ....................................................................................................... 76-77

THERMOMETERS

- Selection Guide ........................................................................................................ 78

- Selection Guide - Temperature Probe (Type K) .......................................................... 78

- Thermometers ..................................................................................................... 79-82

- Environmental Testers ............................................................................................... 79

THERMAL IMAGERS

- Selection Guide ........................................................................................................ 83

- Thermal Imagers .................................................................................................. 84-85

Instruments 1.0

Page 3: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

Certificate of Compliance Test Instruments Selection GuideInstruments1.0

+ Indication only

NOTE:

Testing of operation of earth leakage test button, no instrument is required.

The above is only a guide as many other instruments can be used.

INSTRUMENTMAC-ROG3

T1105 T1120 T1125 T1132 T1151 T1800 T1805 T1820 T1825 T1832 T1851 T2000

PAGE NO. 53 32 32 41 36 37 36 31 32 41 36 37 29

Continuity of bonding • • • • • •

Resistance of earth continuity conductor

• • • • • •

Continuity of ring circuits (if applicable)

• • • • • •

Earth loop impedance test: at main switch

• • •

Prospective short-circuit current at point of control (PSCC) for sub-distribution boards

• • •

Elevated voltage between incoming neutral and external earth

• •+ •+

Earth resistance at electrode (if required)

• • • • • •

Insulation resistance • • • • • •

Voltage at main distribution board with no load for each phase to neutral

Voltage at main distribution board with load (as calculated for full load) for each phase

Voltage at available load (worst condition as calculated for full load) for each phase to neutral

• • •

Operation of earth leakage units

Polarity of points of consumption

• •

Phase rotation at points of consumption for three-phase systems

All switching devices, make-and-break circuits

• • • • • •

Page 4: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0Certificate of Compliance Test Instruments Selection GuideInstruments

InstrumentMAC-ROG3

T1105 T1120 T1125 T1132 T1151 T1800 T1805 T1820 T1825 T1832 T1851 T2000 T416 T419 T60 T70 T860 T890TBM076

TBM079

TBM252

TBM 3030

TBM811

TBM878

TEL11 TEL28TEL 2SC

TEL1 TLB

Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44

Continuity of bonding • • • • • • • •

Resistance of earth continuity conductor • • • • • • • •

Continuity of ring circuits (if applicable) • • • • • • • • •

Earth loop impedance test:at main switch

• • • • •

Prospectiveshort-circuit current at pointof control (PSCC) for sub-distribution boards

• • • • •

Elevated voltage between incoming neutral and external earth • • • • • • • • • •+ •+ •+ •+

Earth resistanceat electrode(if required)

• • • • • • • •

Insulation resistance • • • • • • • •

Voltage at main distribution board with no load for each phase toneutral

• • • • • • • •

Voltage at main distribution board with load (as calculated for fullload) for each phase

• • • • • • • •

Voltage at available load (worst condition as calculated for full load)for each phase to neutral

• • • • • • • • •

Operation of earth leakage units • • • • • • •

Polarity of pointsof consumptio

• • • • • •

Phase rotation at points of consumption for three-phase systems • • • • • • •

All switching devices, make-and-break circuits • • • • • • • • • •

Page 5: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

10

Digital Multimeters - Selection GuideInstruments

FEATURES T820 T835 T1300H T235H T48 TBM805 TBM807 TBM869 TBM252

PAGE 12 12 12 13 13 13 14 14 14

LCD Display (Counts) 1999 1999 1999 1999 1999 4000 4000 5000 000 6000

LCD Display (Digits) 31/2

31/2

31/2

31/2

31/2

33/4

35/6

54/5

35/6

TRUE RMS • • •

Transistor HFE • •

Logic • •

Max AC Voltage (V) 600 500 500 750 750 1000 1000 1000 1000

Max DC Voltage (V) 600 500 500 1000 1000 1000 1000 1000 1000

Max AC Current (A) 20 20 10 10 10 8

Max DC Current (A) 10 10 10 20 20 10 10 10 8

Max Resistance (Ω) 20M 20M 200M 200M 200M 40M 40M 60M 60M

Continuity Beeper • • • • • • • • •

Diode Test • • • • • • • • •

Auto Range • • • •

Frequency (Hz) 200K 1M 1M 1M 1M

Capacitance (F) 200µ 200µ 3000µ 3000µ 25m 3000µ

Temperature (ºC) 1000 1000 1000 300 1000 1000

Min/Max DISPLAY MAX MAX • •

Data Hold • • • • • • • • •

Crest (Peakhold) •

Backlight • • • • •

Splash and Dust Proof • • • •

Transient Proof (kV) 6.5 6.5 12 6.0

Relative Reference • • • •

Bargraph • •

Auto Power Off (APO) • • • • •

USB Interface • •

Data Logger

EF Detect •

Safety Category

Intrinsically Safe

Dual DISPLAY •

Fuse: mA Rating 250mA 250V 250mA 250V 250mA 250V 250mA 250V 250mA 250V 44mA 1000V 630mA 500V

Fuse Size (mm) 5 x 20 5 x 20 5 x 20 5 x 20 5 x 20 10 x 37 6 x 32

Fuse: A Rating 12A 250V 11A 1000V 10A 600V

Fuse: Size (mm) 5 x 20 6 x 25 6 x 25 10 x 37 10 x 37

Lifetime Warranty

CAT III 600V CAT III 600V CAT III 600V CAT IV 1000V CAT III 600V

CAT IV 300V

CAT II 1000VCAT II 1000V

CAT IV 600V

CAT II 1000V

CAT IV 600V

CAT II 1000V

CAT III 600V

CAT II 1000V

CAT III 600V

* LIFETIME WARRANTY

Page 6: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

11

Digital Multimeters - Selection GuideInstruments

TBM239R TBM829* TBM525 TBM811* TBM812* TBM811XEX* TBM812XEX* TBM319 TBM878 T8209

15 15 15 16 16 17 17 18 18 18

6000 6000 10 000 6000 6000 6000 10 000 6000 6000 3999

35/6

39/10

39/10

39/10

39/10

39/10

39/10

35/6

35/6

3

• • • • • • •

• •

1000 1000 1000 1000 1000 1000 1000 1000 1000 750

1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

10 10 10 10 10 10 10 10 10 10

10 10 10 10 10 10 10 10 10 10

60M 60M 60M 60M 60M 60M 60M 60M 60M 40M

• • • • • • • • • •

• • • • • • • • • •

• • • • • • • • • •

50K 1M 1M 1M 1M 1M 1M 1k 5k 1k

2000µ 20m 25m 20m 20m 20m 20m 200µ 30m 100µ

400 1000 1000 1000 1000 1000

• • • • •

• • • • • • • • • •

• •

• • • •

• • • • • • • • • •

6.0 12 12 12 12 12 12 12 12

• • • • • • • • • •

• • • • • • • •

• • • • • • • • • •

• • • • • •

• • •

• • • • •

• • • • • • • •

44mA 1000V 44mA 1000V 1A 600V 1A 600V 44mA 1000V 44mA 1000V 630mA 500V 630mA 500V

10 x 37 10 x 37 10 x 35 10 x 35 10 x 37 10 x 37 6 x 32 6 x 32

11A 1000V 11A 1000V 11A 1000V 10A 600V 10A 600V 11A 1000V 11A 1000V 6.3A 500V 6.3A 500V 10A 600V

6 x 37 6 x 37 6 x 37 6 x 37 6 x 37 6 x 37 6 x 37 6 x 37 6 x 37 6 x 37

• • • • •

CAT III 600V

CAT IV 300V

CAT II 1000V

CAT IV 1000V CAT IV 1000V CAT IV 1000V CAT IV 1000V CAT IV 1000V CAT IV 1000V CAT II 1000V CAT III 1000V CAT III 600V

Page 7: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

12

Digital MultimetersInstruments

Feature Parameter Accuracy

DC Voltage 200mV, 2, 20, 200, 600V ±0.5% + 4 Digit

AC Voltage 200, 500V ±1.2 % + 10 Digit

DC Current 200mA, 2mA, 20mA, 200mA,10A ±1.0 % + 2 Digit

Resistance 200, 2k, 20k, 200k, 20MΩ 0.8% + 10 Digit

Temperature 20°C to 1000°C ±1.0 % + 3 Digit

Counts 3 -1/2 Digits 1999 Counts

Technical Overview

Feature Parameter Accuracy

DC Voltage 200mV, 2, 20, 20, 500V ±0.5% + 2 Digit

AC Voltage 200, 500V ±1.2% + 10 Digit

DC Current 2mA, 20mA, 200mA,10A 2m-200mA ±1% +2 Digit

Resistance 200, 2k, 20k, 200k, 200MΩ ±1% + 5 Digit

Counts 3 -1/2 Digits 1999 Counts

Technical Overview

Feature Parameter Accuracy

DC Voltage 200mV, 2, 20, 200, 600V ±0.5% + 4 Digit

AC Voltage 200, 600V ±1.2 % + 10 Digit

DC Current 200µ, 2mA, 20mA, 200mA,10A ±1.5 % + 3 Digit

Resistance 200, 2k, 20k ,200k ,20MΩ ±1.2% + 4 Digit

Counts 3 -1/2 Digits 1999 Counts

Technical Overview

Power Source 1 x 9V Battery

Model Specification

Power Source 1 x 9V Battery

Standard Accessories Temp Probe TBMTEMPPROBE

Model Specification

Power Source 1 x 9V Battery

Model Specification

CAT III 600V

CAT III 600V

CAT III 600V

T820• DIY • Large LCD display• Continuity• Diode

T835• DIY• Continuity• Diode • Data hold

T1300H• Electronic• Backlit• Diode• Continuity• Data hold

Page 8: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

13

Digital MultimetersInstruments

Feature Parameter Accuracy

DC Voltage 200mV, 2mV, 20, 200, 1000V ±0.5% + 4 Digit

AC Voltage 20V, 200, 750V ±1.2 % + 10 Digit

DC Current 20mA, 200mA ,20A ±1.5 % + 3 Digit

Resistance 200, 20k, 200k,20MΩ, 200MΩ ±1.2% + 4 Digit

Temperature -20°C to 1000°C ±0.8 % + 4 Digit

Capacitance 20nF, 2nF, 2000µF ±2.5 % + 20 Digit

Counts 3 -1/2 Digits 1999 Counts

Technical Overview

Feature Parameter Accuracy

DC Voltage 200mV, 2, 20, 200, 1000V ±0.5% + 3 Digit

AC Voltage 200mV, 2, 20, 200, 750V ±0.8% + 5 Digit

DC Current 20µ, 200µ, 20mA, 200mA, 2A, 20A ±0.8% + 3 Digit

AC Current 200mA, 20A ±1.0% + 5 Digit

Resistance 200, 2k, 200k, 2M, 20M, 2000MΩ ±0.8 % + 3 Digit

Frequency 2k, 200kHz ±0.5% + 4 Digit

Temperature -20°C to 1000°C ±1.0% + 4 Digit

Capacitance 20nF, 200nF, 2µF, 20µF, 200µF 20nF-20µf ±2.5% +20 Digit

Counts 3 -1/2 Digits 1999 Counts

Technical Overview

Power Source 1 x 9V Battery

Standard Accessories Temp Probe TBMTEMPPROBE

Model Specification

Power Source 1 x 9V Battery

Standard Accessories Temp Probe TBMTEMPPROBE

Model Specification

TRMS

Power Source 2 x 1.5V AAA Batteries

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Feature Parameter Accuracy

DC Voltage 400mV, 4, 40, 400, 1000V ±1.0%+4 Digit

AC Voltage 400mV, 4, 40, 400, 1000V 4 -400V ±1.5% + 5 Digit, 1000V ±4.0% + 5 Digit

DC Current 400µ, 4000µ, 40mA, 400mA, 4.10A ±1.2% + 3 Digit

AC Current 400µ, 4000µ, 40mA, 400mA, 4.10A ±1.8% + 4 Digit

Resistance 400, 4k, 40k, 400k, 4M, 40MΩ ±2.0% + 4 Digit

Capacitance 500nF, 5µ, 50µ, 500µ, 3000µF ±3.5% + 6 Digit

Frequency 50k, 500k, 5k, 50k, 500k, 1MHz ±0.5% + 4 Digit

Counts 3 -3/4 Digits 4000 Counts

Technical Overview

CAT III 600V

T235H • Electrician’s• Backlit• Data hold • Capacitance

T48• Electronic • Backlit• Capacitance• Inductance

TBM805• Electrician’s • Splash proof • Beep guard• Rugged construction

• Data hold• Min/Max• Relative zero

Page 9: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

14

Digital MultimetersInstruments

Power Source 2 x 1.5V AAA Batteries

Standard Accessories Temp Probe TBMTEMPPROBE

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Feature Parameter Accuracy

DC Voltage 400mV, 4, 40, 400, 1000V ±1.0%+4 Digit

AC Voltage 400mV, 4, 40, 400, 1000V 4 -400V ±1.5% + 5 Digit, 1000V ±4.0% + 5 Digit

DC Current 400µ, 4000µ, 40mA, 400mA, 4.10A ±1.2% + 3 Digit

AC Current 400µ, 4000µ, 40mA, 400mA, 4.10A ±1.8% + 4 Digit

Resistance 400, 4k, 40k, 400k, 4M, 40MΩ ±2.0% + 4 Digit

Temperature 20°C to 300°C ±2.0% + 3°C

Capacitance 500nF, 5µ, 50µ, 500µ, 3000µF ±3.5% + 6 Digit

Frequency 50k, 500k, 5k, 50k, 500k, 1MHz ±0.5% + 4 Digit

Counts 3 -3/4 Digits 4000 Counts

Technical Overview

• Electrician’s• Beep guard• Data hold

• Min/Max• Relative zero

CAT III 600V

TRMS

Feature Parameter Accuracy

DC Voltage 60mV, 600mV, 6, 60, 600, 1000V ±0.2% + 3 Digit

AC Voltage 60mV, 600mV, 6, 60, 600, 1000V ±0.2% + 3 Digit

DC Current 600µ, 6000µ, 60mA, 600mA, 6.8A ±0.5% + 3 Digit

AC Current 600µ, 6000µ, 60mA, 600mA, 6.8A ±1.0% + 3 Digit

Resistance 600, 6k, 60k, 600k, 6M, 60MΩ ±1.2% + 4 Digit

Temperature -50ºC to 1000ºC

Capacitance 60nF, 600nF, 6µ, 60µ,600µ,3000µF ±2.0% + 5 Digit

Frequency 5Hz - 1MHz ±0.003% + 2 Digit

Auto Check 1V - 1000 V AC/DC

Counts 3 -5/6 Digits 6000 Counts

Technical Overview

TBM252• USB Interface• Non-contact EF detection

• Separate battery compartment

Power Source 1.5V AAA Battery

Standard Accessories Temp Probe TBMTEMPPROBE

Optional Accessories USB Cable and Software TBU20X SEE PG 19, USB Adaptor SEE PG 19,

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Feature Parameter Accuracy

DC Voltage 500mV, 5, 50, 500, 1000V 0.02% + 2 Digit

AC Voltage 500mV, 5, 50, 500, 1000V 1.2% + 40 Digit (20hz-45hz)

DC Current 500µ, 5000µ, 50mA, 500mA, 5.10A 0.15% + 20 Digit (0.5% + 50 Digit att 500µA)

AC Current 500µ, 5000µ, 50mA, 500mA, 5.10A 0.5% + 50 Digit

Resistance 500, 5k, 50k, 500k, 5m, 50mΩ 0.07% + 10 Digit

Temperature -50ºC to 1000ºC 0.3% + 1.5ºC

Capacitance 50nF, 500nF, 5µ, 500µ, 25mf 0.8% + 3 Digit

Frequency Line: Logic

10Hz to 3kHz 0.002% + 4 Digit

Counts 5 -4/5 Digits 500000 Counts

Technical Overview

TBM869• Probe input warning• Crest mode

• Duty cycle• Dual display

Power Source 1 x 9V Battery

Standard Accessories Temp Probe TBMTEMPPROBE

Optional Accessories USB Cable and Software TBU86X SEE PG 19

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

TBM807

CAT IV 1000V

TRMS

CAT III 600V

Page 10: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

15

Digital MultimetersInstruments

CAT IV 300V

TRMS

Power Source 1 x 9V Battery

Standard Accessories Temp Probe TBMTEMPPROBE

Optional Accessories USB Cable and Software TBU86X SEE PG 19, Magnetic Hanger TBMH01

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Feature Parameter Accuracy

DC Voltage 60mV, 600mV, 6, 600, 1000V 0.08% + 2 Digit

AC Voltage 60mV, 600mV, 6, 600, 1000V 2.0% + 3 Digit

DC Current 600µ, 6000µ, 60mA, 600mA, 6A,10A 0.2% + 4 Digit

AC Current 600µ, 6000µ,60mA, 600mA, 6,10A 1.0% + 4 Digit

Resistance 0.1Ω - 60MΩ 1.5% + 5 Digit

Temperature -50ºC to 1000ºC 0.3% + 2ºC

Capacitance 60nF, 600nF, 6µ, 60µ, 600µ, 20mF 5.0% + 5 Digit

Frequency 5Hz - 1MHz 0.004% + 4 Digit

Counts 3 -9/10 Digits 6000 Counts

Technical Overview

TBM239R

TBM829• Splash/Drop proof• USB interface• Dual display

• Non-contact EF• Auto check• Crest (Peak-hold)

• Phase rotation• VFD V Hz• Hz of line level voltage

• Probe input warning• Non-contact EF detection

TBM525• Datalogger• 87 000 points single display mode• 43 000 points dual display mode

• USB interface• Non-contact EF detection

Feature Parameter Accuracy

DC Voltage 60mV, 600mV, 6, 600, 1000V 0.08% + 2 Digit

AC Voltage 60mV, 600mV, 6, 600, 1000V 0.08% + 2 Digit

DC Current 600µ, 6000µ, 60mA, 600mA, 6A,10A 0.8% + 6 Digit

AC Current 600µ, 6000µ, 60mA, 600m, 6,10A 0.8% + 6 Digit

Resistance 0.1Ω - 60MΩ 0.8% + 10 Digit

Temperature -50ºC to 1000ºC 0.3% + 2ºC

Capacitance 60nF, 600nF, 6µ, 60µ, 600µ, 25mF 5.0% + 5 Digit

Frequency 5Hz to 1MHz 0.004% + 4 Digit

Counts 3 -9/10 Digits 10000 Counts

Technical Overview

Power Source 1 x 9V Battery

Standard Accessories Temp Probe TBMTEMPPROBE

Optional Accessories USB Cable and Software TBU86X SEE PG 19, Magnetic Hanger TBMH01

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

CAT III 1000V

TRMS

CAT IV 1000V

TRMS

Power Source 2 x 1.5V AAA Batteries

Optional Accessories Magnetic Hanger TBMH01

Certificates EN6101-1/2-2-030/-2-033

Model Specification

Feature Parameter Accuracy

DC Voltage 60mV, 600mV, 6000V, 60V, 600V, 1000V 0.03% + 2 Digit

AC Voltage 6V, 60V, 600V, 1000V 0.7% + 3 Digit

DC Current 200µA, 2000µA, 6A, 10A 0.7% + 3 Digit

AC Current 200µA, 2000µA, 6A, 10A 1.0% + 3 Digit

Resistance 600Ω - 60MΩ 0.3% + 2 Digit

Temperature -40ºC to 400ºC 1.0% + 1ºC

Capacitance 2000nF, 20µF, 200µF, 2000µF 1.5% + 2 Digit

Frequency 100Hz - 50KHz 0.03% + 2 Digit

Counts 3-5/6 Digits 6000 Counts

VDF ACV 10Hz - 440Hz, 600V, 1000V 2.0% + 3 Digit

Technical Overview

Page 11: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

Power Source 1 x 9V Battery

Optional AccessoriesUSB Cable and Software TBU86X, USB Adaptor SEE PG 19, Magnetic Hanger TBMH01

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

1.0

16

Digital MultimetersInstruments

Feature Parameter Accuracy Protection

DC Voltage 60mV, 600mV, 6600, 1000V 0.08% + 2 Digit 1050Vrms, 1450V peak

AC Voltage 60mV, 600mV, 6, 600, 1000V 2.0% + 3 Digit 1050Vrms, 1450V peak

DC Current 600µ, 6000µ, 60m, 600mA, 6.10A 0.2% + 4 Digit 0.44A/1000V Fuse (IR10kA)11A/1000V Fuse (IR20kA)

AC Current 600µ, 6000µ, 60mA, 600mA, 6.10A 1.0% + 4 Digit0.44A/1000V Fuse (IR10kA)11A/1000V Fuse (IR20kA)

Resistance 40.1Ω - 60MΩ 1.5% + 5 Digit 1.2V DC open circuit

Capacitance 60nF, 600nF, 6µ, 60µ, 600µ, 20mF 5.0% + 5 Digit

Frequency 5Hz - 1MHz ±0.5% + 4 Digit

Input Warning

Transient 12kV surge

Protection (1.2/50 µs) surge

Counts 3 -9/10 Digits 6000 Counts

Technical Overview - TBM811 and TBM811XEX

Power Source 1 x 9V Battery

Optional AccessoriesUSB Cable and Software TBU86X, USB Adaptor SEE PG 19, Magnetic Hanger TBMH01

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Feature Parameter Accuracy Protection

DC Voltage 60mV, 600mV, 6, 600, 1000V 0.08% + 2 Digit 1050Vrms, 1450V peak

AC Voltage 60mV, 600mV, 6, 600, 1000V 2.0% + 3 Digit 1050Vrms, 1450V peak

DC Current 600µ, 6000µ, 60mA, 600mA, 6.10A 0.2% + 4 Digit 0.44A/1000V Fuse (IR10kA)11A/1000V Fuse (IR20kA)

AC Current 600µ, 6000µ, 60mA, 600mA, 6.10A 1.0% + 4 Digit0.44A/1000V Fuse (IR10kA)11A/1000V Fuse (IR20kA)

Resistance 40.1Ω - 60MΩ 1.5% + 5 Digit 1.2V DC open circuit

Capacitance 60nF, 600nF, 6µ, 60µ, 600µ, 20mF 5.0% + 5 Digit

Frequency 5Hz - 1MHz 0.004% + 4 Digit

Input Warning

Transient 12kV surge

Protection (1.2/50 µs) surge

Counts 3 -9/10 Digits 6000 Counts

Technical Overview - and TBM812XEX

LIFETIME WARRANTY

CAT IV 1000V

TRMS

LIFETIME WARRANTY

CAT IV 1000V

TBM811• General Purpose• Splash/Drop proof• 1000V AC/DC• USB interface• Dual display• Backlit

TBM812• General Purpose• Splash/Drop proof• 1000V AC/DC• USB interface• Dual display• Backlit

Page 12: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

17

Digital MultimetersInstruments

TBM811XEX Intrinsically Safe

• 1A/1kV (IR10kA) for µA and mA (1000V HRC Fuse) • 11A/1kV (IR20kA) for A (1000V HRC Fuse)

These meters comply to IEC SANS 60079-0:2000 and IEC SANS 60079-11:1999. which is an electrical apparatus for explosive gas atmospheres. Part 0 (general requirements) and Part 1 (intrinsic). The approved explosive protection rating of this equipment is suitable for use in Zone 1 hazardous area. Group I (coal mines) underground and Group II (surface).

Markings on meter:

• Ex ib I Mb• Ex ib IIC Gb • SAEx MS/09-200X • Ex ib falls under Zone 1 which is an area where flammable gas can occur in

normal operating conditionsLIFETIME WARRANTY

CAT IV 1000V

TBM812XEX Intrinsically Safe

• 1A/1kV (IR10kA) for µA and mA (1000V HRC Fuse) • 11A/1kV (IR20kA) for A (1000V HRC Fuse)

These meters comply to IEC SANS 60079-0:2000 and IEC SANS 60079-11:1999. which is an electrical apparatus for explosive gas atmospheres. Part 0 (general requirements) and Part 1 (intrinsic). The approved explosive protection rating of this equipment is suitable for use in Zone 1 hazardous area. Group I (coal mines) underground and Group II (surface).

Markings on meter:

• Ex ib I Mb• Ex ib IIC Gb • SAEx MS/09-200X • Ex ib falls under Zone 1 which is an area where flammable gas can occur in

normal operating conditions

LIFETIME WARRANTY

CAT IV 1000V

TRMS

Technical Overview see TBM811

Technical Overview see TBM812

TBM811XEX• General Purpose• Splash/Drop proof• 1000V AC/DC• USB interface• Dual display• Backlit

TBM812XEX• General Purpose• Splash/Drop proof• 1000V AC/DC• USB interface• Dual display• Backlit

Page 13: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

Power Source 4 x 1.5V AA Batteries

Standard AccessoriesTemp Probe TBMTEMPPROBE, Croc clips TBM878CLIP, Test Lead Adaptor TBM878TIPS, Test Lead TBM878LEAD, Industrial Test Probe TBM878PROBE

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Feature Parameter Accuracy

DC Voltage 60mV, 600mV, 6, 600, 1000V 0.09% + 3 Digit

AC Voltage 60mV, 600mV, 6, 600, 1000V 2.0% + 3 Digit

DC Current 60mA, 400mA 0.4% + 3 Digit

AC Current 60mA, 400mA 1.5% + 3 Digit

Resistance 600, 6k, 60k, 600k, 6M, 60MΩ 1.5% + 3 Digit

InsulationResistance

50V(3M-55MΩ),100V(3M-110MΩ), 250V(3M-275MΩ)550V(3M-550MΩ), 1000V (3M-25GΩ)

1.5% + 3 Digit

Temperature -50ºC to 1000ºC 9% + 2.0ºC

Capacitance 3µ,30µ,300µ,3000µF,30mF 10% + 5 Digit

Frequency 10Hz - 5KHz 0.02% + 4 Digit

Counts 3 -5/6 Digits 6000 Counts

Technical Overview

1.0

18

Digital MultimetersInstruments

Feature Parameter Accuracy

DC Voltage 60mV, 600mV, 6, 600, 1000V 0.4% + 3 Digit

AC Voltage 60mV, 600mV, 6, 600, 1000V 2.0% + 5 Digit

DC Current 600µ, 6000µ, 60mA, 600mA, 6, 10A 0.7% + 3 Digit

AC Current 600µ, 6000µ, 60mA, 600mA, 6, 10A 2.2% + 5 Digit

Resistance 600, 6k, 60k, 600k, 6M, 60MΩ 0.5% + 5 Digit

Temperature -50ºC to 1000ºC 0.5% + 3 Digit

Capacitance 6µ, 60µ, 600µ, 2000µF 2.0% + 5 Digit

Frequency 10Hz - 1kHz 0.1% + 3 Digit

IP-RPM 240-20000RPM (Inductive)

IG-RPM 60-20000RPM (Contact)

DWELL 0.0º - 360º 1.2º/kRPM + 1 Digit

FUEL INJECTOR 0.05ms - 250.0ms 0.05ms + 1 Digit

Technical Overview

Power Source 2 x 1.5V AAA Batteries

Standard Accessories Temp Probe TBMTEMPPROBE, Banana Plug BKP60, Inductive Pickup Clip BP300

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Feature Parameter Accuracy

DC Voltage 400mV, 4, 40, 400, 1000V ±0.7% + 2 Digit

AC Voltage 4, 40, 400, 750V ±1.0% + 3 Digit

DC Current 400µA, 400mA, 10A ±2.0% + 10 Digit

AC Current 400µA, 400mA, 10A ±3.0% + 10 Digit

Resistance 400, 4k, 40k, 400k, 40MΩ ±2.0% + 5 Digit

Temperature ±20°C to 1000°C ±3.0% + 5 Digit

Capacitance 4.40nF, 400nF, 4µ, 40, 100µF ±3.0% + 3 Digit

Frequency 10Hz - 1kHz ±2.0% + 5 Digit

Humidity 20~95% RH ±5.0% RH

Sound Level (dB) 40~100dB ±3.5% at 94dB

Illuminance 1~40000 Lux ±5.0% + 10 Digit

Duty Cycle 0.1~99.9% ±3.0%

Counts 3 Digits 3999 Counts

Technical Overview

Power Source 3 x 1.5V AAA Batteries

Standard Accessories Carry Pouch, Temp Probe TBMTEMPPROBE

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

CAT II 1000V

TRMS

CAT III 1000V

dB

%Rh

VΩA

CAT III 600V

TBM319 Automotive Tester• Splash/Drop proof• Selectable 4-stroke /2-stroke

• Sensitivity on RPM• Selectable 1 to 12 cylinders

TBM878 Insulation/Combination• Industrial test probe• Earth bond resistance

• VFD AC Voltage• Relative zero

T8209 Multipurpose 5-in-1• Test probe input warning lights • Diode test

Page 14: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

Code TBRUSB TBM135 TBM157 TBM195 TBM197

Page No. 19 25 29 28 29

TBU13X

• • •

TBU19X

• •

Code TBRUSB TBM252 TBM811 TBM812 TBM525 TBM829 TBM869

Page No. 19 14 17 16 15 15 14

TBU20X

• •

TBU86X

• • • • •

Free Software updates available: www.brymen.com/product-html/software-download/

1.0

19

AccessoriesInstruments

TBRUSB (USB Adaptor) - Fits TBU20X, TBU13X, TBU19X

Digital Multimeters

Clamp Meters

TBU Software• Optical interface adaptor• USB Cable and software

Page 15: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

20

Digital Clamp Meters - Selection GuideInstruments

FEATURES TBM3030 TM175D TBM072 TBM076 TBM086 T98 T260D TBM116 TBM118 TBM135 T77N

PAGE 22 22 22 23 23 23 24 24 24 25 25

MAX AC Current (A)

600 600 600 600 1000 1000 1000 1000 2000 1000 100

MAX DC Current (A)

2

MAX AC Voltage (V)

600 600 600 600 1000 750 750 600 600 600

MAX DC Voltage (V)

600 600 600 600 1000 1000 1000 600 600 600

MAX Resistance (Ω)

40M 6M 60k 60k 60k 2k 2M 40M 6M 1k

Jaw Size (mm)

26 30 30 30 51 42 60 45 45 45 40

Temperature(°C)

400 400 400

Continuity • • • • • • • • • •

Frequency (Hz)

100k 1000k 100k 100k 100k 30k 500

Capacitance(F)

3000µ 2500µ 2500µ 2500µ 2000µ 2000µ

Diode • • • • • • • • • •

Display (Counts)

4000 4000 6000 6000 6000 1999 1999 4000 6000 6000 6000

Blacklight • • • • • • • •

Auto Range • • • • • • • • •

Data Hold • • • • • • • • • • •

Min/MaxDisplay

• • • • • • • • •

AmptipTM • • • •

TRUE RMS • • • • • • • •

Data Logging

Safety Category

CAT III 300V CAT III 600VCAT IV 300V CAT III 1000VCAT III 600V CAT III 600V CAT III 600V CAT III 600V CAT III 600V CAT III 600V CAT III 300V

Page 16: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

21

Digital Clamp Meters - Selection GuideInstruments

TF3000 T223 TBM061 TBM062 TBM079 T8056 TBM162 TBM089 T2608 TBM195 TBM197 TBM157

25 26 26 26 27 27 27 28 28 28 29 29

3000 100 400 400 600 1000 800 1000 1500 2000 2000 1000

100 400 400 600 1000 1000 1000 2000 2000 2000

600 600 600 600 700 600 1000 750 1000 1000 600

600 600 600 600 1000 600 1000 1000 1000 1000 600

10k 40M 40M 60k 40M 40M 60k 40M 40M 40M 999.9

110 12.5 30 30 35 42 50 51 57 55 55 45

400 750 400 1000

• • • • • • • • • • •

500 100k 100k 400 100k 1000k 400k 400k 400 400 500

3000µ 3000µ 2500µ 40µ 3000µ 2500µ 40µ 2000µ 2000µ

• • • • • • • • • •

3000 4 Digits 4000 4000 6000 4000 4000 6000 4000 6000 6000 6000

• • • • • • •

• • • • • • • • • • • •

• • • • • • • • • • • •

• • • • • • • • • • • •

• •

• • • • • • • •

• • •

CAT IV 600V CAT III 300V CAT III 600V CAT III 600V CAT III 600V CAT III 600V CAT III 600V CAT IV 600V CAT III 600VCAT IV 1000VCAT IV 1000VCAT III 1000V

Page 17: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

22

Digital Clamp MetersInstruments

Feature Parameter Accuracy

AC Current 40, 600A ±1.9%+ 8 Digit

DC Current

AC Voltage 4, 40, 400, 600V 4.40, 400V ±1.5% + 5 Digit, 600V ±2.0% + 5 Digit

DC Voltage 400mV, 4, 40, 400, 600V ±1.0%+ 4 Digit

Resistance 400, 4k, 40k, 400k, 4M, 40MΩ4k, 40k, 400kΩ ±0.6%+4 Digit, 4MΩ ±1.0% + 4 Digit, 40MΩ ±2.0% + 4 Digit

Capacitance 500nF, 5µ, 50µ, 500µ, 3000µF ±3.5% + 6 Digit

Frequency 5Hz to 100kHz ±0.5% + 4 Digit

Counts 3 -3/4 Digits 4000 Counts

Technical Overview

Feature Parameter Accuracy

AC Current 40, 600A ±1.8%+ 5 Digit

DC Current

AC Voltage 4, 40, 400, 600V 4.40, 400V ±1.5% + 5 Digit, 600V ±1.2% + 7 Digit

DC Voltage 400mV, 4, 40, 400, 600V ±1.0%+ 5 Digit

Resistance 600, 6kΩ, 60kΩ 1.0% + 5 Digit

Frequency 5Hz to 100kHz ±0.5% + 4 Digit

Counts 3 -5/6 Digits 6000 Counts

Technical Overview

Power Source 1 x 3V Battery CR2032

Standard Accessories Carry Pouch

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Power Source 2 x 1.5V AAA Batteries

Standard Accessories Carry Pouch

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

CAT III 300V

TRMS

AmpTip™

CAT IV 300V

TBM3030 600A AC• Jaw size: 26mm• Large LCD display• Diode

• Continuity• Relative zero• Data hold

Feature Parameter Accuracy

AC Current 60-600A 1.5% + 5 Digit

DC Current 200mA, 2A 1.0% + 5 Digit

AC Voltage 4, 40, 400, 600V 1.0% + 5 Digit

DC Voltage 400mV, 4, 40, 400, 600V 1.0% + 5 Digit

Temperature -40º to 400º -40º - 100º 1.0% + 0.8º, 100º - 400º, 1% + 1º

Resistance 600Ω, 6MΩ600kΩ, 6kΩ, 60kΩ, 1.0% + 5 Digit, 600kΩ, 60MΩ 1.5% + 5 Digit

Capacitance 5200nF, 2500µF 2.0% + 4 Digit

Frequency 10Hz to 1000kHz 0.5% + 4 Digit

Counts 3 -3/4 Digits 4000 Counts

Technical Overview

Power Source 2 x 1.5V AAA Batteries

Standard Accessories Carry Pouch

Certificates UL, IEC61010-1. EMC EN61326-1:2013. Certificate of Conformance

Model Specification

TRMS

AmpTip™

CAT IV 300V

TBM175D 600A AC• Jaw size: 30mm• AmptipTM

• Rotary selector switch

• Dual display• Non-contact EF detection• VFD, V & Hz feature

TBM072 600A AC• Jaw size: 30mm• AmptipTM • Large LCD display • Rotary selector switch

• Continuity• Data hold• Non-contact EF detection

Page 18: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

23

Digital Clamp MetersInstruments

Feature Parameter Accuracy

AC Current 40, 600A ±1.8%+ 5 Digit

DC Current

DC Voltage 400mV, 4, 40, 400, 600V ±1.0%+ 5 Digit

AC Voltage 4, 40, 400, 600V 440, 400V ±1.5% + 5 Digit, 600V ±1.2% + 7 Digit

Resistance 600, 6kΩ, 60kΩ 600kΩ, 6kΩ, 60kΩ, ±1.0% + 5 Digit

Temperature -40°C to 400°C ± 1% - 0.8°C, 100°C - 400°C ±1.0% - 1°C

Frequency 5Hz to 100kHz ±0.5% + 4 Digit

Capacitance 200µ, 2500µF ± 2% + 4 Digit

Counts 3 -5/6 Digits 6000 Counts

Technical Overview

Feature Parameter Accuracy

AC Voltage 600, 1000V ±1.8%+ 5 Digit

DC Voltage 600, 1000V

AC Current 60, 600, 1000A 4, 40, 400V ±1.5% + 5 Digit, 600V ±1.2% + 7 Digit

DC Current ±1.0%+ 5 Digit

Resistance 600, 6kΩ, 60kΩ4k, 40k, 400kΩ ±0.6% +4 Digit, 4mΩ ±1.0% + 4 Digit, 40mΩ ±2.0% + 4 Digit

Temperature -40°C to 400°C ± 1% - 0.8°C, 100°C - 400°C ±1.0% - 1°C

Frequency 5Hz to 100kHz ±0.5% + 4 Digit

Capacitance 200µ, 2500µF ± 2% + 4 Digit

Counts 3 -5/6 Digits 6000 Counts

Technical Overview

Feature Parameter Accuracy

AC Current 20, 200, 1000A ±2.0% + 5 Digit

DC Current

AC Voltage 750V ±1.0% + 5 Digit

DC Voltage 1000V ±1.0% + 2 Digit

Resistance 200, 2000Ω ±1.0% + 3 Digit

Temperature -40°C to 750°C ±1.0% + 5 Digit

Counts 3 -1/2 Digits 1999 Counts

Technical Overview

Power Source 2 x 1.5V AAA Batteries

Standard Accessories Carry Pouch, Temp Probe TBMTEMPPROBE

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Power Source 2 x 1.5V AAA Batteries

Standard Accessories Carry Pouch, Temp Probe TBMTEMPPROBE

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Power Source 1 x 9V Battery

Standard Accessories Carry Pouch, Temp Probe TBMTEMPPROBE

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

TRMS

AmpTip™

CAT IV 300V

TRMS

AmpTip™

CAT III 1000V

CAT III 600V

TBM076 600A AC• Jaw size: 30mm• AmptipTM

• 3-Phase rotation for mains and motor• Non-contact EF detection

• Rotary selector switch• Continuity• Data Hold

TBM086 1000A AC• Jaw size: 51mm• AmptipTM

• 3-Phase rotation for mains and motor

• Non-contact EF detection• Rotary selector switch• Peak RMS 80ms in-rush current

T98 1000A AC• Jaw size: 42mm• Backlit• Continuity• Data hold

Page 19: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

24

Digital Clamp MetersInstruments

Feature Parameter Accuracy

DC Current

AC Current 20, 200, 1000A ±2% + 5 Digit

DC Voltage 200mV, 20, 200, 1000V ±0.5% + 1 Digit

AC Voltage 200, 750V ±1.2% + 10 Digit

Resistance 200, 2k, 20k, 200k,2MΩ ±1.0% + 2 Digit

Counts 3 -1/2 Digits 1999 Counts

Technical Overview

Feature Parameter Accuracy

DC Current

AC Current 400, 2000A 1.5% + 5 Digit

DC Voltage 6, 60, 600V 2% + 5 Digit

AC Voltage 660, 600V 1.5% + 5 Digit

Resistance 6k, 60k, 600k, 6MΩ 1.2% + 4 Digit

Frequency 10 to 50kHz 0.5% + 4 Digit

Capacitance 100nF, 1000nF, 10µ, 100µ, 2000µF 3.5% + 5 Digit

Counts 3 -5/6 Digits 6000 Counts

Technical Overview

Feature Parameter Accuracy

DC Current

AC Current 400, 1000A ±1.8%+ 5 Digit

DC Voltage 400mV, 4, 40, 600V ±1.0%+ 5 Digit

AC Voltage 4, 40, 400, 600V ±4, 40, 400V ±1.5% + 5 Digit, 600V ±1.2% + 7 Digit

Resistance 400, 4k, 40k, 400k, 40MΩ4k, 40k, 400kΩ ±0.6% +4 Digit , 4mΩ ±1.0% + 4 Digit, 40mΩ ±2.0% + 4 Digit

Counts 3 -3/4 Digits 4000 Counts

Technical Overview

Power Source 1 x 9V Battery

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Power Source 2 x 1.5V AAA Batteries

Standard Accessories Carry Pouch

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Power Source 2 x 1.5V AAA Batteries

Standard Accessories Carry Pouch

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

CAT III 600V

TRMS

CAT III 600V

TRMS

CAT III 300V

T260D 1000A AC • Jaw size: 60mm• Combination Clamp• Diode• Continuity buzzer

TBM116 1000A AC • Jaw size: 45mm • Auto Check• Diode

• Continuity• Relative zero• Data hold

TBM118 2000A AC • Jaw size: 45mm• Auto Check• Emf detection• Diode

• Continuity• Relative zero• Data hold

Page 20: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

25

Digital Clamp MetersInstruments

Feature Parameter Accuracy

DC Current

AC Current 40, 400, 1000A 2.0% + 5 Digit

DC Voltage 600V 0.5% + 5 Digit

AC Voltage 600V 1.5% + 5 Digit

Resistance 999.9Ω 1.0% + 6 Digit

Temperature -50 to 300°C

Frequency 5 to 500Hz ±0.5% + 4 Digit

Thd%-r 0.0%~99.9%Fundamental 1% + 6 Digit2~3 Harmonics 5% + 6 Digit4~51 St Harmonics 2%

Counts 3 -5/6 Digits 6000 Counts

Technical Overview

Feature Parameter Accuracy

AC Current0.1mA, 6mA60A100A

6mA ±1.0% rdg + 8 Digit60A ±1.0% rdg + 8 Digit100A ±2.0% rdg + 10 Digit

Counts 4 Digits 6000 Counts

Technical Overview

Power Source 2 x 1.5V AAA Batteries

Standard Accessories Carry Pouch, Type-K Thermocouple

Optional Accessories RS232 Cable and Software TBU13X, Adaptor SEE PG 19

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Power Source 2 x 1.5V AAA Batteries

Standard Accessories Carry Pouch

Certificates UL, IEC61010-1

Model Specification

Power Source 2 x 1.5V AAA Batteries

Standard Accessories Carry Pouch

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

TRMS

CAT III 300V

TRMS

CAT III 300V

TRMS

CAT III 1000V

Feature Parameter Accuracy

AC Current0.1A, 30A300A3000A

30A ±3 % + 5 Digit300A ±3 % + 5 Digit3000A ±3 % + 5 Digit

Counts 4 Digits 3000 Counts

Technical Overview

TBM135 1000A• Jaw size: 45mm • AC Data Logger

• 5400 Point logging• Continuity

T77N AC• Earth Leakage • Data hold• Low pass filter with high stability 100Hz• Autorange• Bargraph• Auto backlit sensor• Frequency compare function

TF3000 3000A AC• Jaw size: 110mm• Flexible jaw (254mm length)• Sample rate (4 times/second)• Backlit• Data hold

Page 21: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

26

Digital Clamp MetersInstruments

Feature Parameter Accuracy Protection

DC Current 1mA, 10mA, 10A, 100A ±2 % + 10 Digit 150A Rms

AC Current 1mA, 10mA, 10A, 100A ±2 % + 10 Digit 150A Rms

DC Voltage 0.1V, 600V 0.08% + 2 Digit 660Vrms

AC Voltage 0.1V, 600V 2.0% + 3 Digit 660Vrms

Resistance 1. 10kΩ ±1 % + 3 Digit

Technical Overview

Feature Parameter Accuracy

DC Current 0.01, 400A ±2.5% + 5 Digit

AC Current 0.01, 400A ±2.5% + 5 Digit

DC Voltage 400mV, 4, 40, 400, 600V ±1.0% + 4 Digit

AC Voltage 4, 40, 400, 600V 1.5% + 5 Digit

Resistance 400, 4k, 40k, 400k, 4M, 40MΩ4k, 40k, 400kΩ ±0.6%+4 Digit, 4MΩ ±1.0% + 4 Digit, 40MΩ ±2.0% + 4 Digit

Frequency 1kHz to 100kHz ±2.0% + 4 Digit

Capacitance 500nF, 5µ, 50µ, 500µ, 3000µF ±3.5% + 6 Digit

Counts 3 -3/4 Digits 4000 Counts

Technical Overview

Feature Parameter Accuracy

DC Current 0.01, 400A ±2.5% + 5 Digit

AC Current 40.01, 400A ±2.5% + 5 Digit

DC Voltage 400mV, 4, 40, 400, 600V ±1.0% + 4 Digit

AC Voltage 4, 40, 400, 600V 4, 40, 400V ±1.0% + 4 Digit, 600V ±2.0% + 4 Digit

Resistance 400, 4k, 40k, 400k, 40MΩ4k, 40k, 400kΩ ±0.6%+4 Digit, 4MΩ ±1.0% + 4 Digit, 40MΩ ±2.0% + 4 Digit

Frequency 1kHz to 100kHz ±2.0% + 4 Digit

Capacitance 500nF, 5µ, 50µ, 500µ, 3000µF ±3.5% + 6 Digit

Counts 3 -3/4 Digits 4000 Counts

Technical Overview

Power Source 2 x 1.5V AAA Batteries

Standard Accessories Carry Pouch

Model Specification

Weight 218g

Power Source 2 x 1.5V AAA Batteries

Standard Accessories Carry Pouch

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Standard Accessories Carry Pouch

Power Source 2 x 1.5V AAA Batteries

Standard Accessories Carry Pouch

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

CAT III 300V

CAT III 600V

TRMS

CAT III 300V

T223 100A AC/DC • Jaw size: 12.5mm• Automotive• Concurrent reading• Resistance • Continuity

TBM061 400A AC/DC• Jaw size: 30mm• Diode• Continuity

• Relative zero• Auto power off

TBM062 400A AC/DC• Jaw size: 30mm• Diode• Continuity

• Relative zero• Auto power off• Backlit

Page 22: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

27

Digital Clamp MetersInstruments

Feature Parameter Accuracy

DC Current 40, 600A

AC Current 40, 600A ±1.8%+ 5 Digit

DC Voltage 400mV, 4, 40, 400, 600V ±1.0%+ 5 Digit

AC Voltage 4, 40, 400, 600V 4, 40, 400V ±1.5% + 5 Digit, 600V ±1.2% + 7 Digit

Resistance 600, 6k, 60kΩ4k, 40k, 400kΩ ±0.6% +4 Digit, 4mΩ ±1.0% + 4 Digit, 40mΩ ±2.0% + 4 Digit

Temperature -40°C to 400°C 4mΩ ±1.0% + 4 Digit

Frequency 50Hz to 400Hz 40mΩ ±2.0% + 4 Digit

Capacitance 200µ, 2500µF

Counts 3 -5/6 Digits 6000 Counts

Technical Overview

TBM079 600A AC/DC• Jaw size: 35mm • AmptipTM

• 3-Phase rotation for mains and motors

• Non-contact EF detection• Rotary selector switch• Data hold

T8056 1000A AC/DC • Jaw size: 42mm• Duty cycle• Diode• Continuity

• Auto power off• Relative zero• Data hold

Power Source 2 x 1.5V AAA Batteries

Standard Accessories Carry Pouch, Temp Probe TBMTEMPPROBE

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Power Source 1 x 9V Battery

Standard Accessories Carry Case, Temp Probe TBMTEMPPROBE

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Feature Parameter Accuracy

DC Current 400, 1000A ±3.0% + 3 Digit

AC Current 400, 1000A ±3.0% + 3 Digit

DC Voltage 60mV, 600mV, 6, 600, 1000V ±0.8% + 3 Digit

AC Voltage 60mV, 600mV, 6, 600, 1000V ±1.0% + 10 Digit

Resistance 400, 4k, 40k, 400k, 4m, 40MΩ ±2.0% + 3 Digit

Temperature -40°C to 750°C ±1.0% + 6 Digit

Frequency 40, 400, 4k, 40k, 100kHz ±2.0% + 1 Digit

Capacitance 4nF, 40nF, 400nF, 4µ, 40µF ±4.0% + 10 Digit

Counts 3 -3/4 Digits 4000 Counts

Technical Overview

Power Source 2 x 1.5V AAA Batteries

Standard Accessories Carry Pouch

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Feature Parameter Accuracy

AC Current 400, 800A 400A, ±2.0% + 5 Digit, 800A, 5.0% + 30 Digit

DC Current 400, 1000A ±0.5 % + 3 Digit

AC Voltage 600V ±2 % + 5 Digit

DC Voltage 600V ±2 % + 5 Digit

Resistance 400, 4k, 4M, 40MΩ ±1.0 % + 4 Digit

Capacitance 500nF, 5µ, 50µ, 500µ, 3000µF ±3.5 % + 6 Digit

Frequency 15Hz- 1000Hz

Counts 3 -3/4 Digits 4000 Counts

Technical Overview

TRMS

CAT III 600V

TRMS

AmpTip™

CAT III 600V

CAT III 600V

TBM162 1000A AC/DC• Jaw size: 50mm• Large display• Max hold

• Continuity• Diode• Backlit

Page 23: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

28

Digital Clamp MetersInstruments

Feature Parameter Accuracy

DC Current 100, 200, 500, 1000, 2000A ±2 % + 5 Digit

AC Current 100, 200, 500, 1000, 2000A ±2 % + 5 Digit

DC Voltage 6, 60, 600, 1000V ±1.2 % + 5 Digit

AC Voltage 6, 60, 600, 1000V ±1.2 % + 5 Digit

Resistance 600, 6k, 60k, 6M, 40MΩ ±0.5 % + 5 Digit

Capacitance 60nF, 6µ, 60µ, 600µ, 2000µF ±2.0 % + 5 Digit

Frequency 400Hz

Counts 3 -5/6 Digits 6000 Counts

Technical Overview

Feature Parameter Accuracy

DC Current 400, 2000A ±1.5% rdg + 5 Digit

AC Current 400, 1500A ±1.5% rdg + 5 Digit

DC Voltage 400mV, 4, 40, 400, 1000V ±0.5% rdg + 1 Digit

AC Voltage 400mV, 4, 40, 400, 750V ±1.5% rdg + 4 Digit

Resistance 400, 4k, 40k, 400k, 4M, 40MΩ ±1.0% rdg + 4 Digit

Frequency 10, 1k, 10k, 100k, 400kHz ±0.1% rdg + 4 Digit

Capacitance 4nF, 40nF, 400nF, 4µ, 40µF ±1.0% rdg + 4 Digit

Counts 3 -3/4 Digits 4000 Counts

Technical Overview

Power Source 2 x 1.5V AA Batteries

Standard Accessories Carry Pouch

Optional Temp Probe TBMTEMPPROBE, TBU19X SEE PG 19

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Power Source 1 x 9V Battery

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Power Source 2 x 1.5V AA Batteries

Standard Accessories Carry Pouch, Temp Probe TBMTEMPPROBE

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Feature Parameter Accuracy

DC Current 60, 600, 1000A

AC Current 60, 600, 1000A ±1.8%+ 5 Digit

DC Voltage 600, 1000V ±1.0%+ 5 Digit

AC Voltage 600, 1000V 4, 40, 400V ±1.5% + 5 Digit, 600V ±1.2% + 7 Digit

Resistance 600, 6k, 60kΩ4k, 40k, 400kΩ ±0.6% +4 Digit, 4mΩ ±1.0% + 4 Digit, 40mΩ ±2.0% + 4 Digit

Temperature -40°C to 400°C ±1.0% + 6 Digit

Frequency 5Hz to 400kHz ±0.5% + 4 Digit

Capacitance 2500µF

Counts 3 -5/6 Digits 6000 Counts

Technical Overview

TRMS

AmpTip™

CAT IV 1000V

TRMS

CAT IV 1000V

TRMS

CAT III 1000V

TBM089 1000A AC/DC• 3-Phase rotation for mains and motors• AmptipTM

• Non-contact EF detection

• Rotary selector switch• Continuity• Flashlight

T2608 2000A DC/ 1500A AC• Jaw size: 57mm• Min/Max• Data hold/Peak hold• Auto power off

• Diode• Continuity• Bargraph

TBM195 2000A AC/DC• Jaw size: 55mm• Dual display• Non-contact EF detection• VFD (Variable frequency drives)

• Relative zero• Data logging• Autocheck• Diode

Page 24: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

29

Digital Clamp MetersInstruments

Feature Parameter Accuracy

DC Current 100, 200, 500, 1000, 2000A ±2 % + 5 Digit

AC Current 100, 200, 500, 1000, 2000A ±2 % + 5 Digit

DC Voltage 6, 60, 600, 1000V ±1.4 % + 7 Digit

AC Voltage 6, 60, 600, 1000V ±1.4 % + 7 Digit

Resistance 600, 6k, 60k, 6M, 40MΩ ±0.5 % + 5 Digit

Frequency 400Hz

Temperature -50°C to 1000°C ±0.3 % + 4 Digit

Capacitance 60nF, 6µ, 60µ, 600µ, 2000µF ±2.0 % + 5 Digit

Counts 3 -5/6 Digits 6000 Counts

Technical Overview

Power Source 2 x 1.5V AA Batteries

Standard Accessories Carry Pouch

Optional Accessories Temp Probe TBMTEMPPROBE, TBU19X SEE PG 19

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Power Source 2 x 1.5V AAA Batteries

Standard Accessories Carry Case, Temp Probe TBMTEMPPROBE

Optional Accessories RS232 Cable and Software TBU13X, USB Adaptor SEE PG 19

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Feature Parameter Accuracy

AC Current 40, 400, 1000A 2.2% + 5 Digit

DC Voltage 600V 0.5% + 5 Digit

AC Voltage 600V 1.5% + 5 Digit

Resistance 999.9Ω 1.0% + 6 Digit

Frequency 5 ~ 500Hz 0.5% + 4 Digit

Power0.00 ~ 600kVA, 0.00 ~ 600kW 0.00 ~ 600kVAR

±4.0% + 10 Digit

Thd%-fTotal harmonic distortion

0.0% ~ 999.9%Fundamental 1.5%+6 Digit2~3 Harmonics 7%+6 Digit4~51 Harmonics 2%+6 Digit

Count 3 -5/6 Digits 6000 Counts

Technical Overview

T2000 Earth Resistance Clamp• Jaw size: 32mm • Direct earth probes measurement• Leakage current• Alarm thresholds

• Current noise• Data HOLD function • 99 measurement storage locations

Power Source 4 x 1.5V AAA Batteries

Standard Accessories Resistive Test Loop, Carry Case

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Feature Parameter Accuracy

Resistance

0.01Ω~0.999Ω0.10Ω~0.99Ω1Ω~49.9Ω50.0Ω~99.9Ω100Ω~199.9Ω200Ω~395Ω400Ω~590Ω600Ω~1000Ω

±(1.0%+0.01Ω)±(1.0%+0.01±(1.5%+0.1Ω)±(2.0%+0.3Ω)±(3.0%+1Ω)±(6.0%+5Ω)±(10%+10Ω)±(20%+20Ω)

AC Current

0.00A~80mA80~650mA650~999.5mA1.000~3.995mA4.00~20.00mA

±(2.5%+1mA)±(2.5%+2mA)±(2.5%+0.003A)±(2.5%+0.01A)±(2.5%+0.05A)

Technical Overview

TRMS

CAT III 600V

TRMS

CAT IV 1000V

CAT III 150V

TRMS

TBM197 2000A AC/DC• Jaw size: 55mm• Dual display• Non-contact EF detection

• VFD (Variable frequency drives)• Data logging• Diode

TBM157 1000A AC• Jaw size: 45mm• 3-Phase Power Clamp

• Total power factor• Data logging

Page 25: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

30

Earth Resistance Testers - Selection GuideInstruments

FEATURES T416 T1805 T1105 T1820 T1120 T2000

PAGE 31 31 32 32 32 29

Earth Resistance Test (Ω) 50k 1k 1.2k 2k 2k 1k

Earth Resistance Test (V) 460 30 30 200 200

Micro Processor Controlled •

Long Test • • • • •

Auto Power Off (APO) • •

PC Connection •

Data Saving • •

On Display Help •

Backlight • •

Data Hold • • • •

Test Cables Resistance Compensation

• •

Ground Resisting 4 Wire •

Detection of Disturbances Currents

• •

Taut Band Movement • •

Battery Check • • • • •

Safety Category

*

*Optional accessory software TOPVIEW and USB Cable (T416)

CAT III 265V CAT III 150V CAT III 200V CAT III 150VCAT IV 30V CAT II 300V

Page 26: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

31

Earth Resistance Testers Instruments

Feature Parameter Accuracy

Measuring Ranges

Resistance: 10, 100, 1.000Ω

Earth Voltage 30V AC (5kΩ/V)

Measuring System

Resistance: (Constantcurrent inverter 820Hzapprox, 2mA)Voltage: rectifier type0 - 30 VAC, 40~500 Hz

Withstand Voltage

1.500V AC (one minute) ±1.8% + 4 Digit

Resistance ±2.5% of full scale

Voltage ±1% of full scale

Technical Overview

Power Source 8 x 1.5V AA Batteries

Standard AccessoriesTest Leads (Lengths: Red - 1 Meter and 15 Meters, Yellow - 10 Meters, Green - 5 Meters) Earth Spikes, Shoulder Belt

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Power Source 6 x 1.5V AA Batteries

Standard AccessoriesCables and 4 rods, Carry case, English instruction manual, Test Leads (Lengths: Red - 13 Meters, Blue - 20 Meters, Green - 6 Meters, Green - 6 Meters

Optional Accessories Software and USB Cable TOPVIEW

Certificates UL, IEC61010-1. Calibration Certificate ISO9000.Certificate of Conformance

Model Specification

Earth Resistance Measurement

Range Re (Ω) 0.0 - 19.99 20.0 - 199.9 200 - 1999

Resolution (Ω) 0.01 0.1 1

Accuracy ±(2% Reading + 3 digits)

Measuring Frequency

125Hz / 75Hz/41.66Hz ±1Hz

Test Current ≤ 10mA

Open Circuit Voltage

≤ 30V

Wave form of test voltage

Sinusoidal

GROUND RESISTIVITY Measurement

Range p 0.6 - 19.99Ωm

0.125 - 1.256kΩm

1.25 - 19.99kΩm

20.0 - 199.9kΩm

Resolution 0.1Ωm 0.001kΩm 0.01kΩm 0.1kΩm

Accuracy ±(2% Reading + 3 digits)

Measuring Frequency

125Hz / 75Hz / 41.66Hz ±1Hz

Test Current ≤ 10mA

Open Circuit Voltage

≤ 30V

Wave form of test voltage

Sinusoidal

Measurement of DISTURBANCE voltage

Range (V) 500

Resolution (V) 1

Accuracy ±(2% Reading + 3 digits)

Technical Overview

CAT III 265V

CAT III 150V

T416• Earth Resistance Tester• 350 Memory locations• RS232 interface• Resistivity• 2 Wire earth resistance measurements

(2 WIRES)• Three wire earth resistance

measurements (3 WIRES)

• Calculation of earth resistance average value with both two and three wires (RAVG)

• Calculation of resistivity average value (ρAVG)

• 4 Wire method

T1805 • Analogue Earth Resistance Tester• Large display • Taut band movement• 2 and 3 Wire tester

Page 27: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

32

Earth Resistance TestersInstruments

Feature Parameter Accuracy

Measuring Ranges

Resistance: 0-12Ω, 0-120Ω, 0-1200Ω

Earth Voltage 30V AC (5kΩ/V)

Measuring System

Earth resistance by Constant current inverter Hz approx, 2mA square signal

Resistance ±3% of full scale

Voltage ±2.5% of full scale

Technical Overview

Power Source 8 x 1.5V AA Batteries

Standard AccessoriesTest Leads (Lengths: Red - Meter and 15 Meters, Yellow - 10 Meters, Green - 5 Meters) Earth Spikes, Shoulder Belt

Model Specification

Feature Parameter Accuracy

Measuring Ranges

Resistance: 20, 200, 2kΩ

Earth Voltage 200V AC (40 - 500hz)

Measuring System

Earth resistance by constant current inverter, 820Hz, 2mA Approx

Over voltage indication

1 (MSD)

Resistance ±2% rdg + 2 Digit

Voltage ±1% rdg + 2 Digit

Counts 3 -1/2 Digits 2000 Counts

Technical Overview

Power Source 8 x 1.5V AA Batteries

Standard AccessoriesTest Leads (Lengths: Red - Meter and 15 Meters, Yellow - 10 Meters, Green - 5 Meters) Earth Spikes, Shoulder Belt

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Feature Parameter Accuracy

Measuring Ranges

Resistance: 20Ω, 200Ω, 2kΩ

Earth Voltage 0-200V AC

Measuring System

Earth resistance by Constant current inverter 820Hz approx, 2mA square signal

Withstand Voltage

1.500V AC (one minute)

Resistance ±2.0 % + 2 Digit

Voltage ±1.0 % + 2 Digit

Technical Overview

Power Source 8 x 1.5V AA Batteries

Standard AccessoriesTest Leads (Lengths: Red - Meter and 15 Meters, Yellow - 10 Meters, Green - 5 Meters) Earth Spikes, Shoulder Belt

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

CAT III 300V

CAT II 300V

CAT IV 300V

T1105 • Earth Resistance Tester• Analogue display• Safety voltage protection• Compact design

T1820• Digital Earth Resistance Tester• Earth voltage detection

• 2mA earth resistance to test • 2 and 3 Wire Testing

T1120• Digital Earth Resistance Tester• Safety voltage protection

• Compact design

Page 28: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

33

Compliance TestersInstruments

Code Instrument Page Number

TCTCS Case

TCTCDTFM Foam

T1151 1000V Digital Insulation Tester 37

T1120 Digital Tester 32

TEL1TLB ELCB /Polarity Socket Tester 44

T1125 LOOP/PSC Tester 41

TBM3030 Digital Clamp Meter 22

T890 Phase Rotation Tester 45

Code Instrument Page Number

TCTCS Case

TCTCDKFM Foam

T1800 Insulation Tester 36

T1805 Analogue Earth Resistance Tester 31

TEL1TLB ELCB /Polarity Socket Tester 44

T1825 Loop/PSC Tester 41

TBM811 Digital Multimeter 16

T860 Phase Rotation and Motor Rotation 46

Code Instrument Page Number

TCTCS Case

TCTDTFM Foam

T1851 Digital Insulation Tester 37

T1820 Digital Earth Resistance Tester 32

TEL1TLB ELCB /Polarity Socket Tester 44

T1825 LOOP/PSC Tester 41

TBM3030 Digital Clamp Meter 22

T887 LCD Phase Rotation 46

TCTCDK Compact Digital Compliance Kit • Kit supplied in a sturdy case with foam cut out to secure each instrument• Refer to individual products for technical overview

TCTDT Digital Compliance Kit• Kit supplied in a sturdy case with foam cut out to secure each instrument• Refer to individual products for technical overview

TCTRP Analogue Compliance Kit• Kit supplied in a sturdy case with foam cut out to secure each instrument• Refer to individual products for technical overview

Page 29: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

FEATURES T1132 T1800 T1832 T1851 T1151 T10020C T5050 TIN4D TIN5D TIN6D TIN6A TIN7D TIN8D

PAGE 36 36 36 37 37 38

Insulation Tester Voltage (V) 1000 1000 1000 1000 1000 1000 5kv 5kv 10kv 10kv 10kv 10kv

Insulation Resistance Ranges (Ω)

250V/100M

500V/200M

1000/400M

250V/100M

500V/200M

1000/400M

250V/100M

500V/200M

1000/400M

250V/200M

500V/200M

1000/200M

250V/2G

500V/4G

1000/200M

500

50M

500V/

50M

500V/25GΩ

1kV/500GΩ

2.5k/125Ω,

5k/250Ω

1kV/50G

2.5k/125Ω,

5k/250Ω

10kV/250Ω

500V/25GΩ

10kV/500Ω

1000/200MΩ

5kV/200GΩ

10kV/400Ω

800kΩ

500GΩ

500V/700GΩ

15kV/2TΩ

Micro Processor Controlled • • • • • • •

Bargraph • • • • • •

Counting Timer • • • • •

Long Test • • • • • • •

Auto Range • • • • • • •

Auto Power Off (APO) • • • • • •

Auto Discharge • • • • • • • • • • • •

External Voltage Warning Indication • • • • • • •

Live Circuit Warning • • • • • • • • •

PI Polarisation Index • • • • • •

Eeprom Calibration • • • • •

Backlight • •

Data Hold •

Relative

Auto Null •

Fuse Protection • • • • • • • • • •

B.S. 16TH Edition • • • •

Mirror Scale • •

Taut Band Movement • • • •

AC Measurement (V) 500 500 500 500 700 500 500

DC Measurement (V) 950 500 500

Hand Free Testing Locker • • •

Battery Check • • • • • • • • •

Continuity Test Range (Ω) 3/500 50 3/500 200/ 2000 1999 5k 5kΩ

DAR (Dialectical Absorption Ratio) • • •

Lifetime Warranty • • •

Safety CategoryCAT III (V)

300V

CAT III (V) 300V

CAT III (V) 300V

CAT III (V) 300V

1.0

34

Insulation Testers - Selection GuideInstruments

CAT III 500V CAT III 500V CAT III 500V CAT III 500V CAT III 600V

Page 30: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

FEATURES T1132 T1800 T1832 T1851 T1151 T10020 T5050C TIN4D TIN5D TIN6D TIN6A TIN7D TIN8D

38 38 39 39 39 40 40

Insulation Tester Voltage 1000V 1000V 1000V 1000V 1000V 1000V 5kv 5kv 10kv 10kv 10kv 10kv 15k

Insulation Resistance Ranges

250V/100MΩ

500V/200MΩ

1000/400MΩ

250V/100MΩ

500V/200MΩ

1000/400MΩ

250V/100MΩ

500V/200MΩ

1000/400MΩ

250V/200MΩ

500V/200MΩ

1000/200MΩ

250V/2GΩ

500V/4GΩ

1000/200MΩ

500V/

50M

500V/

50M

500V/25G

1kV/500G

2.5k/125Ω, 5k/250

1kV/50G

2.5k/125,

5k/250

10kV/250

500V/25G

10kV/500

1000/200M

5kV/200G

10kV/400

800k

500G

500V/700G

15kV/2T

Micro Processor Controlled • • • • • • •

Bargraph • • • • • •

Counting Timer • • • • •

Long Test • • • • • • •

Auto Range • • • • • • •

Auto Power Off • • • • • •

Auto Discharge • • • • • • • • • • • •

External Voltage Warning Indication • • • • • • •

Live Circuit Warning • • • • • • • • •

PI Polarisation Index • •

Eeprom Calibration • • • • •

Backlight •

Data Hold •

Relative

Auto Null •

Fuse Protection • • • • • • • • • •

B.S. 16TH Tdition • • • •

Mirror Scale • •

Taut Band Movement • • • •

AC V Measurement (V) 500 500 500 500 700 500 500

DC V Measurement 950 500 500

Hand Free Testing Locker • • •

Battery Check • • • • • • • • •

Continuity Test Range (Ω) 3/500 50 3/500 200Ω/ 2000Ω 1999 5kΩ 5k

DAR (Dialectical Absorption Ratio) • • •

MOV (Metal Oxide Varistor)

Safety CategoryCAT III (V)

500V

CAT III (V) 500V

CAT III (V) 500V

CAT III (V) 500V

CAT III (V) 600V

1.0

35

Insulation Testers - Selection GuideInstruments

CAT III 300V CAT III 300V CAT III 300V CAT III 300V CAT III 300V CAT IV 600V

Page 31: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

36

Insulation TestersInstruments

Feature Parameter Accuracy

Test Voltages and measuring range

250V 0-100MΩ, 500V 0-200MΩ, 1000V 0-400MΩ

Voltage ±2% of scale length

Short circuit terminal current 145mA DC Approx Insulation ±5% of Indicated value

Output Voltage on open circuit Rated test voltage + 10%

Short Circuit Current (Max) 2mA DC

Continuity Range 0 -50Ω

Open circuit terminal voltage 445mV DC Approx

Voltage Measurement 0 -500 VAC

Technical Overview

Power Source 8 x 1.5V AA Batteries

Standard AccessoriesTest Leads (Lengths: Red - Meter and 15 Meters, Yellow - 10 Meters, Green - 5 Meters) Earth Spikes, Shoulder Belt

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Power Source 8 x 1.5V AA Batteries

Certificates Certificate of Conformance

Model Specification

Technical Overview

Insulation Test Voltage 250, 500, 1000V

Insulation Resistance 250V (100MΩ), 500V (200MΩ), 1000V (400MΩ)

AC Voltage 0 to 600V

Ohm meter 3 to 500Ω

Feature Parameter Accuracy

Test Voltages and measuring range

250V 0-100MΩ, 500V 0-200MΩ, 1000V 0-400MΩ

Voltage ±3% of scale lengt

Short circuit terminal current 210mA DC Approx Insulation ±5% of Indicated value

Output Voltage on open circuit Rated test voltage + 10%

Short Circuit Current (Max) 1.3mA

Continuity Range 0 -50Ω

Open circuit terminal voltage 445mV DC Approx

Voltage Measurement 0 -500 VAC

Technical Overview

Power Source 8 x 1.5V AA Batteries

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

LIFETIME WARRANTY

CAT III 500V

LIFETIME WARRANTY

CAT III 500V

CAT III 500V

T1132 1000V • Analogue Insulation Tester• Safety voltmeter protection• Live circuit indication• Auto discharge• AC voltage measurement• Zero adjustment knob

T1800 1000V• Analogue Insulation Tester• Heavy duty carry case• Taut band movement• Auto discharge

• Colour coded scale• Live circuit indication• AC Voltage measurement

T1832 1000V• Analogue Insulation Tester • Taut band movement• Live circuit indication• 200mA continuity short circuit current• Auto discharge

• AC voltage measurement• Rugged construction• Nulling of test leads • Continuity buzzer• Mirror scale

Page 32: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

37

Insulation TestersInstruments

Feature Parameter Accuracy

Test Voltages and measuring range

250V 0-200MΩ, 500V 0-200MΩ, 1000V 0-2000MΩ

Voltage ±1.5 % + 3 Digit

Short circuit terminal current 210mA DC Approx Insulation ±1.5 % + 5 Digit

Output Voltage on open circuit Rated test voltage + 10%

Short Circuit Current (Max) 1mA

Continuity Range 0-2kΩ

Open circuit terminal voltage 445mV DC Approx

Voltage Measurement 0 -500 VAC

Counts 3 -1/2 Digits 2000 Counts

Technical Overview

Power Source 8 x 1.5V AA Batteries

Certificates UL, , IEC61010-1. Certificate of Conformance

Model Specification

Power Source 8 x 1.5V AA Batteries

Certificates Certificate of Conformance

Model Specification

Technical Overview

Insulation Test Voltage 250,500,1000V

Insulation Resistance 250V (2k-2GΩ), 500V (4k-4GΩ), 1000V (8k-8GΩ)

AC Voltage 0 to 700V

Ohm meter 0.01 to 1999Ω

Test Current >SH220mA

T1151 1000V and T11510LED Insulation Testers

• Digital Insulation Tester• Safety voltmeter protection• Live circuit indication• Auto discharge• AC voltage measurement• OLED Display (Organic light-emitting diode - T11510LED)

T1151 1000V and T11510LED

CAT III 500V

CAT III 500V

LIFETIME WARRANTY

LIFETIME WARRANTY

T1851 1000V• Digital Insulation Tester• Continuity buzzer • Live circuit warning• 210mA continuity short circuit current

• AC voltage measurement• Auto power off• Auto discharge• Live circuit indication

T1151

T115150LED

Page 33: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

38

Insulation TestersInstruments

Power Source Mechanical winder

Standard Accessories Case, Leads

Model Specification

Technical Overview

Test Voltage 1000V

Insulation Resistance 5000MΩ

Power Source Mechanical winder

Standard Accessories Case, leads

Model Specification

Technical Overview

Rated Voltage 1000V

Insulated Resistance 200MΩ

Continuity Range 0 - 50kΩ

Accuracy±5 % Over First Effective Range±10 % Over 2nd Effective Range

Power Source 8 x 1.5V C Batteries Alkaline

Standard Accessories Carry Pouch

Certificates Certificate of Conformance

Model Specification

Insulation Test Voltage 500V 1000V 2500V 5000V

Insulation Resistance 0-30GΩ 0-60GΩ 0-125GΩ 0-250GΩ

Accuracy ±3% reading + 2 digit

Output Current Limit 50µA to 100µA

Live Warning >500 Volts

Operating Temperature 0 to 40°C

Operating Humidity 85% Max relative humidity

Technical Overview

T10020C 1000• Hand Crank• Sturdy movement suitable for stringent fieldwork• Built-in discharge facility for operator safety• Accurate and stable reading using knife-edge pointer• Improved AC brushless generator• Dust protected terminals

T5050C 500V• Hand Crank• Cross coil movement suitable for stringent fieldwork• Built-in discharge facility for operator safety• Accurate and stable reading using knife-edge pointer• Improved AC brushless generator• Guard terminal to minimise effect of surface leakage current

TIN4D 5KV• Displays insulation test time• Displays warning• Fully protected crow bar• Insulation test time interval up to 99 sec• Auro range• 4 Insulation test voltage

Page 34: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

39

Insulation TestersInstruments

Power Source 8 x 1.5V C Batteries Alkaline

Standard Accessories Carry Pouch

Certificates EN61010-1. Certificate of Conformance

Model Specification

Insulation Test Voltage 1000V 2500V 5000V 10000V

Insulation Resistance 0-60GΩ 0-125GΩ 0-250GΩ 0-500GΩ

Accuracy ±3% reading + 2 digit

Output Current Limit 50µA to 100µA

Live Warning >500 Volts

Operating Temperature 0ºC to 40ºC

Operating Humidity 85

Technical Overview

Power Source 6 x 1.5V C Batteries

Certificates Certificate of Conformance

Model Specification

Feature Parameter Accuracy

Insulation Test Voltage 5kV 10kV

Insulation Resistance 0-200GΩ 0-400GΩ

Accuracy ±5% of scale length

Output Power Limit 50µA to 100µA

Live Warning >500 V AC

Operating Temperature 0ºC to 40ºC

Operating Humidity 85

Technical Overview

Power Source 8 x 1.5V C Batteries Alkaline

Standard Accessories Carry Pouch

Certificates EN61010-1. Certificate of Conformance

Model Specification

Feature Parameter

Insulation Test Voltage 500V - 10kV

Measuring Range (Autoranging)500V - 10kV,25GΩ - 500GΩ

Output Power Limit 1W

Short Circuit Current (Max) 1.25mA

Insulation Accuracy ±3% + 1 Digit

Technical Overview

CAT III 300V

TIN5D 10kV• Auto ranging on all ranges• Displays insulation test time• Displays warning• Fully protected crow bar• Insulation test time interval up to 99 sec• 4 Insulation test voltage

TIN6D 10kV• 20 Insulation test voltages

(500V - 10kV)• Heavy duty carry case• Silicone test leads• Anti skid/vibration absorbing enclosure• Live circuit warning

• Auto discharge• Insulation test time interval

up to 99 sec• Auto range• Auto off

TIN6A 5kV-10kV• Live circuit warning• Auto discharge• Battery life indication • Heavy duty carry case• Silicon test leads• 2 Test voltage: 5kV and 10kV

Page 35: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

40

Insulation TestersInstruments

TIN7D 10kV and TIN7DOLED 10kV

TIN7D

TIN7DOLED

Power Source 8 x 1.5V C Batteries Alkaline

Certificates EN61010-1, EN61326-1. Certificate of Conformance

Model Specification

Feature Parameter Accuracy

Insulation Test Voltage500V, 10kV (20 x 500V increments)

±5% + 1 Digit

Measuring Range 0-250GΩ, 800kΩ to 500gΩ

Output Power Limit 1W

Short Circuit Current (Max) 1.25mA

Dielectric Absorption Ratio Yes R @ 1 min

Polarisation Index Yes R @ 1 min

Technical Overview

TIN7D 10kV and TIN7DOLED 10kV Insulation Testers• Polarisation index*• Dielectric absorption ratio*• Live circuit warning• Auto discharge• Insulation test time interval up to 10 mins• 20 Insulation test voltage• Auto range• OLED Display (Organic light-emitting diode - TIN7DOLED)

CAT III 300V

CAT III 300V

Power Source Rechargeable Battery with AC charge

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Feature Parameter Accuracy

Insulation Test Voltage500V, 15kV (500V increments)

±5% + 5 Digit

Measuring Range70GΩ/0.5kV 70GΩ at 0.5kV - 2TΩ at 15kV

Short Circuit Current (Max) Up to 5mA

Dielectric Absorption Ratio Yes

Polarisation Index Yes

Technical Overview

CAT IV 600V

TIN8D 15kV• Insulation test voltage up to 15kV• Test insulation resistance up to 2 TΩ

(2000GΩ)• Short circuit current up to 5mA• Auto hold function to freeze

the reading• Overload protection• 30 insulation test voltages

• Adjustment for testing time (duration) : 1~30 minutes

• Software included• USB to RS-232 data transmission.• 200 Measurement results can be

saved and recalled on the display

* Polarisation and dielectric ratio are useful to schedule maintenance. The user can keep record of the PI and DAR results and analyse these over time. Maintenance can be done according to analysis and down time can be scheduled thus saving production time.

Page 36: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

41

PSC Loop TestersInstruments

Power Source 8 x 1.5V AA Batteries

Standard Accessories Carry Case, Strap, Leads

Certificates UL, IEC61010-1. Certificate of Conformance IEC61326-1

Model Specification

Feature Parameter Accuracy

Measuring :Loop :PSC

0 ~ 2000Ω0 ~ 6kA @ 230V AC

± 5% ± 2 Digit

± 12% + 5 Digit

Operating Voltage (VAC) 230V ± 20V 50Hz ± 2%

TEST CURRENT - Loop/PSC/Load 11.76A

Neutral Wire Resistance 0.01 - 2000Ω

Live Wire Resistance 0.01 - 2000Ω

PSC Current (L-N) Max 6kA @ 230V AC

PSC Current (L-E) Max 6kA @ 230V AC

Operating Temperature -10˚C to 40˚C

Humidity 80% Max Relative humidity

Technical Overview

CAT III 300V

LIFETIME WARRANTY

Power Source 8 x 1.5V AA Batteries

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Measuring :Loop :PSC

0 ~ 2000Ω0 ~ 6ka @230v (L-n)

Operating Voltage (VAC) 50 ~275V AC 50 or 60Hz

TEST CURRENT - Loop/PSC/Load 12A (Load Voltage shown as @ 16A

Resolution (ohm) 0.01 (Loop)

Thermal Protection Electronic

Accuracy Voltages ±1% (210 ~ 250V)

Accuracy Loop ±2% (0.05 ~ 50Ω), ±3% (500Ω), ±15% (above 500Ω)

Operating Temperature 0 to 40˚C

Humidity 85%

Technical Overview

CAT III 300V

T1826 - PSC Loop Tester• Fault finding• Electrical network analyser• Earth resistance without peg

• Analyse to SANS 10142• Loop test for L-E, L-N and PSC

T1125• Load/No load tester• PSC (Prospective short circuit current)• Safety voltmeter protection• Micro processor controlled

• Test up to 100A (6kA) circuit breakers• Each phase tested separately on

a 3-Phase system• Designed to SANS 10142

Power Source 8 x 1.5V AA Batteries

Standard Accessories Carry Case, Strap, Leads

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Feature Parameter Accuracy

Measuring :Loop :PSC

0 ~ 2000Ω0 ~ 6kA @230V (L-n)

±2% (0.05 ~ 50Ω), ±3% (500Ω), ±15% (above 500Ω)

±12% + 5 Digit

Operating Voltage (VAC) 50 ~275V AC 50 or 60Hz 6KA @ 230V AC

TEST CURRENT - Loop/PSC/Load

12A (Load Voltage shown as @ 16A)

Resolution (ohm) 0.01 (Loop)

Thermal Protection Electronic

PSC Current 600kA @ 230V AC

(L-N) Max ±2% (0.05 ~ 50Ω), ±3% (500Ω), ±15% (above 500Ω)

Operating Temperature -10 to 40˚C

Humidity 85% Max relative humidity

Technical Overview

LIFETIME WARRANTY

CAT III 300V

T1825 - PSC Loop Tester• Load/No load tester• Prospective short circuit current• Volt drop test• Micro processor controlled

• Test up to 100A (6kA) circuit breakers• 3-Phase system test• Designed to SANS 10142

Page 37: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

42

Loop, ELCB and Polarity TestersInstruments

Instruments listed below are to be used in conjunction with the TIMP57 in order to do high line loop tests up to 400kA

Power Source 8 x 1.5V C Batteries

Standard Accessories 2 Test Cables (3m length, with Alligator Clips), RS-232 Serial Cable, Carrying Bag

Certificates ISO9000 Calibration Certificate, Certificate of Conformance

Model Specification

Type of measurement P-N, P-P, P-PE Loop/Line impedance and short circuit current calculation

Resolution of ohms 0.1mΩ(Zloop) ; 1A (Ipsc)

Test current approx: 200A

Frequency range 50Hz ±5%

Short Circuit Current (Max) 1.25mA

Dielectric Absorption Ratio R @ 1 min

Polarisation Index R @ 10 min

Technical Overview

Power Source No batteries requiRed

Certificates Certificate of Conformance

Model Specification

Feature Parameter Accuracy

Operating Voltage 550 550Vac @ ±15%

ELCB current 10mA - 50mA30A ±3 % + 5 Digit 0.01A

Frequency of Operation 50/60Hz

Voltage (L-E) 1% (1mA)

Meter ±1% of full scale

Operator Temperature -5˚C to 45˚C

Fuse Protected 0.1A Fast Blow

Technical Overview

Power Source 8 x 1.5V AA Batteries Alkaline

Certificates Certificate of Conformance EN 0081-1. EN 50082-1

Model Specification

Feature Parameter Accuracy

Rated tripping current 0 to 1000mA ± 1mA

Resolution 1mA

Operating Voltage (L-E) 100 to 450V AC 50 - 50V AC 2% ± 1V 350 - 450V AC

Maximum Trip Time 100 secs (1mS resolution) 1mS ± 1mS 5% ± 1V

Operating Temperature -50ºC to 40ºC

Operating Humidity 80%

Phase Angle Setting 0 and 180º selectable

Technical Overview

LIFETIME WARRANTY

CAT III 450V

TIMP57Accessory for measuring and recording the efficiency of single-phase and 3-Phase multi-string systems

• Line Loop Adaptor• Test up to 400kA

TEL2SC• ELCB Tester/Polarity• Taut band movement• Wiring check• Robust• Two and three wire operation• Designed to SANS 10142

TEL28• Industrial ELCB• Micro-processor• Direct read out of time/current• Voltage measurement • Suitable for industrial, mining and

domestic environments

• Each phase tested separately on a 3-Phase system industrial, mining and domestic environments

• Designed to SANS 10142

MACROG3 T419 T60

Page 38: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

43

ELCB and Polarity TestersInstruments

Feature Range Accuracy

Resistance Ranges

0 to 200Ω in steps of 100µΩ0 to 2000mΩ in steps of 1Ω0 to 20Ω in steps of 10Ω0 to 200Ω in steps of 100mΩ

±0.5% of reading ±2 digits

Test Current1mA = 2000Ω range 10mA = 200Ω range 100mA = 2000mΩ range

Maximum Output Voltage 380/550 volts

Test Current Accuracy ±0.1%

Technical Overview

Power Source 12V DC battery poweRed, 8 x 1.5V C Batteries Alkaline

Standard Accessories Test Leads, Shoulder Belt

Certificates Certificate of Conformance

Model Specification

Feature Parameter Accuracy

Rated Tripping Current 0-1000mA at 317 Volts ±1% reading ±2 digits

Lowest Resolution 1mA to 10ms

Operating Voltage 380, 550V 1% reading ±1 digit

Maximum Trip Time 99.99 secs

Operating Temperature 0ºC to 40ºC

Operating Humidity 80%

Technical Overview

Power Source 6 x 1.5V C Batteries Alkaline

Certificates Certificate of Conformance

Model Specification

LIFETIME WARRANTY

Power Source 8 x 1.5V AA Batteries Alkaline

Certificates Certificate of Conformance EN 61326-1

Model Specification

Feature Parameter Accuracy

Rated Tripping Current 3mA - 500mA 5% ± 1mA

Operating Voltage (L-E) 20V AC to 280V AC 2% ± 1V AC

Maximum Trip Time 3secs (1mS resolution) 2% ± 2mS

Operating Temperature -5ºC to 45ºC

Operating Humidity 80%

Phase Angle Setting 0º or 180º

Technical Overview

LIFETIME WARRANTY

CAT III 240V

T1812• Automatic data hold function• Zero crossing testing at 0º or 180º• Disconnection phase polarity• Polarity trip indicator (positive or

negative phase)

• Wiring polarity indicator• Measures voltage and frequency

between line and earth before testing

T4137• Digital Milliohm Meter• Four terminal measurement • Large LCD display• Robust lightweight case with

O-ring seal

• Bonding tests• Earth continuity testing• Designed to SANS 10142

TELE10L• Industrial ELCB• Micro processor• Fully programmable (Direct readout - time or current)• Voltage measured during test

Page 39: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

44

ELCB and Polarity TestersInstruments

Feature Parameter

Current Settings 999mAac/50Hz

Phase-start-selection 0°C and 180°C

Operating Voltage (L-E) 60Vac to 317Vac (525V System)

Timer Resolution 1mS (Max Time = 99.99s)

Current Resolution 1mA

Voltmeter Resolution 1V

Earth Leakage Constant Current IAC 5 to 999 (mA) @50Hz

Ramping Current 5 to 999 (mA)

Sensitivity Disconnection Check 5 to 999 (mA)

Time Delay Disconnection Check(s) 0.001 - 99.999

Maximum Current Consumption 10mA

ELCB Voltage Measurement (L-E) (V AC) 10 to 330V

ELCB Tester Voltage Present (VELCB) LED

ELCB Fuse (Slow Blow) 1.5A

Technical Overview

Power Source 8 x 1.5V C Batteries Alkaline

Standard Accessories Test Leads x 2 (terminate own plug)

Certificates Certificate of Conformance

Model Specification

TEL11 ELCB/Phase Rotation Tester and TEL11OLED ELCB/Phase Rotation Tester

• 3-Phase presence• 3-Phase rotation• TEST for disconnection sensitivity• TEST for disconnection time• Select one of 3-Phase to test ELCB• Measure voltage phase to Earth• Over temperature protection• Phase polarity trip indicator

TEL11 and TEL11OLED

TEL11

TEL11OLED LIFETIME WARRANTY

LIFETIME WARRANTY

Rated Tripping Current 10, 15, 20, 25, 30, 35mA

Resolution 5mA

Operation Voltage 220V

Technical Overview

TEL1TLB• Socket• ELCB Tester/Polarity• Live on earth indication (LCD Display)• Identifies 6 wiring conditions• Earth tripping function• Floating earth detection• Ready-board compatible• LCD displays a floating earth when wiring is incorrect and brass knob is touched • Designed to SANS 10142

Page 40: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

45

ELCB and Phase Rotation TestersInstruments

Standard Accessories Carry Pouch

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Operating Voltage 150 to 1000VAC

Operating Frequency 45 to 65Hz

Circuit Structure Electronic

Operating Temperature -10ºC to 50ºC

Humidity 80%

Power Source 4 x 1.5 AA Batteries

Current Consumption 15mA

Cable Length Approx 800mm

Technical Overview

CAT III 1000V

0-10kΩ

Pote

ntio

met

er to

te

st a

udio

& v

isua

l

Blue OFF RedPhase selection switch

Voltage output pointsfor multimeter

V+

V+

Earth

Line 1 Blue

Line 2Red

Earth Reference

Line 2 Red

Line 1Blue

Plug conFiguration

±115V

±230V

±115V

http://www.hellermanntyton.co.za/downloads.html

Application video

Standard Accessories Carry Pouch

Certificates Certificate of Conformance

Model Specification

Operating Voltage 90 - 600 VAC

Operating Frequency 50/60 Hz

Operating Temperature -10ºC to 40ºC at 80%

Humidity Max relative humidity

Cable Length 1.1m each of Red (R), White (S) and Blue (T)

Technical Overview

TIMT• Line Insulation Monitor Tester• Testing of IT supply systems from high impedance transformers• Test between earth reference and phase with output connections for a multimeter• Test Insulation monitoring alarm by adjusting the potentiometer to verify the audio

and visual indication

T890• 3-Phase Detector (Non-contact)• Clamps over wire insulation without contact on conductor• Non-contact sensor clips• Open phase and phase sequence• Magnets on back of unit to mount on metal surfaces

T855• 3-Phase Rotation Indicator• Fused test leads• Rotating disc• Colour coded Red/white/Blue• Large alligator clips• Real motor behaviour

Page 41: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

46

Phase Rotation TestersInstruments

Standard Accessories Carry Pouch

Certificates Certificate of Conformance

Model Specification

Operating Voltage 100 to 600VAC

Operating Frequency 45 to 75Hz

Circuit Structure Electronic

Operating Temperature 0ºC to 50ºC at 90º

Humidity Max relative Humidity

Power Consumption (Correct)

±14mA for motor rotation field test±7mA for Phase rotation field indication

Technical Overview

LIFETIME WARRANTY

Standard Accessories Carry Pouch

Certificates Certificate of Conformance

Model Specification

Operating Voltage 40 - 700 VAC

Operating Frequency 50/60 Hz

Operating Temperature -1ºC to 55ºC

Humidity Not in full sunlight

Cable Length 60cm each of Red( R), White (S) and Blue (T)

Technical Overview

LIFETIME WARRANTY

T860• 3-Phase and Motor Rotation Indicator• Test rotation of unconnected motors• Heavy duty alligator clips • Open phase identification• Phase presence• Colour coded: Red/White/ Blue

T887• 3-Phase Rotation LCD Indicator• Phase rotation and phase presence• Colour coded Red/White/Blue• Large alligator clips

Page 42: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

47

Miscellaneous, Voltage and Phase Rotation TestersInstruments

Operating Voltage 1000V to 1000V

Frequency 50/60 Hz

Certificate IEC/EN61010-1

Technical Overview

http://www.hellermanntyton.co.za/downloads.html

Application videoIncorrect phase sequence

Correct phase sequence

Power Source 4 x 1.5V LR44 Batteries

Model Specification

Technical Overview

Voltage Detection 5V ~1000V AC

Current Sensitivity >100mA

Frequency Range 50 to 500Hz

Operating Temperature -10°C to 50°C

Operating Humidity <80 %RH

CAT IV 1000V

Power Source TX: 1 x 9V Battery, RX: Mains

Certificates Certificate of Conformance

Model Specification

Operating Voltage 200 - 250 V AC

Frequency 47 - 63Hz

Duty Cycle 10µs

Transmitter Power Wall Socket

Receiver Power 1 x 9V Battery

Technical Overview

T70• Phase Sequence Indicator and Voltage Detector• Detection AC voltage• Phase sequence and conformity test with 1 wire method• With or without contact measurements• LED Red and buzzer indication• Practical pen clip• Clamp voltage detectors together

T475• Volt/Current Tracer• Detect current through shielded/armoured cable• Adjustable sensitivity• Non-contact• Visual and Audio

T534 • Circuit Breaker Identifier• Tracing plug sockets to circuit breakers• Battery check• Signal strength buzzer• Calibrate funtion by moving receiver across circuit breakers• Wiring indications

Page 43: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

48

Voltage Testers and Surge ProtectionInstruments

Power Source Probe: 1 x 9V Battery, Tone: 1 x 9V Battery

Standard Accessories Carry Pouch

Certificate Certificate of Conformance

Model Specification

Tone Generator

Waveform Square Ware

Frequency ±1.13kHz

Amplitude 9V P-P

Over voltage Protection ±100V

Amplifier Probe

Frequency Detection 1-12kHz

Receiver distance 50-60cm

Sensitivity Control √

Technical Overview

100mm 65mm

Operating Voltage 120 - 250 V AC

Technical Overview

Code Size

T45200 100mm

T45000 65mm

TSP1A Surge Plug Top (Green)

TSP1AF Surge Plug Top (Red)

Flat PinRated Voltage 230V/50Hz

Max Continuous Operating Voltage

275V AC

Max Continuous Current 16A

Max Surge Current 8kA

Fusing Integrated 104ºC Thermal and 16A over current fuse

Temperature Range -10°C to 70°C

Technical Overview

Certificates SANS 164-0 Approval

Standards Compliance IEC 61643-1

Model Specification

T180 Tone and Probe Kit• With tone generator and amplifier probe• Sensitivity control• Alligator clips and RJ11 connector• Single or dual alternating tone• Use on de-energised circuits

Surge Plugs• High surge handling capability• Incorrect power socket wiring detection• Economical secondary protection• Thermal and over-current fusing• Visual fault indication• Differential and common mode protection• 2 Year warranty

T45200/T45000• Neon Screwdrivers

Page 44: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

49

Voltage TestersInstruments

Operating Voltage 50V - 1000V AC

Frequency 50 - 500Hz

Technical Overview

Power Source 2 x AAA 1.5V Batteries

Certificates EN:61010-1, EN:61326-1

Model Specification

CAT III 600V

Operating Voltage 5V - 1000V AC

Frequency 50 - 500Hz

Technical Overview

Power Source 1 x AAA 1.5V Battery

Certificates CE EN:61010-1, EN:61326-1

Model Specification

CAT IV 1000V

Power Source 4 x 1.5V LR44 Batteries T515BATT

Model Specification

Operating Voltage 70 - 600V AC

Technical Overview

TS500 • Non-contact voltage detection• Audio/visual/vibration indication• Polarity check• Microwave leakage

TLVD15• Non-contact voltage detection• LED and tone indication• Flashlight

TLVD17• Non-contact voltage detection• Sensitivity adjustable • LED and tone indication• Identifies live and neutral

Page 45: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

50

Voltage TestersInstruments

Power Source No Batteries

Certificates IP65, IEC61243-3, DIN/VDE 0682-401

Model Specification

Power Source No Batteries

Certificates IEC61010-1

Model Specification

Operating Voltage 110 - 750V AC/DC

Technical Overview

Voltage Range 110V, 230V, 380V, 690V, 1000V AC/DC

Technical Overview

Voltage Range 6V,12V, 24V, 50V, 120V, 230V, 400V, 690V, 1000V

Transient protection 8kV

Technical Overview

Power Source No Batteries

Optional Accessories Wibreneon (spare neon optional)

Model Specification

CAT IV 1000V

CAT III 1000V

WIBRETEST• Industrial Heavy Duty• AC/DC• Neon Indication (Green, Red)• Polarity• Oil resistant

WIBRE1000• Dust and waterproof• AC/DC• IP65• LED indicators• Polarity• Oil resistant

TBT69• Industrial• Polarity LED indicators• Electric field detection• LCD display• RCD (ELCB) tripping (30mA)• Continuity• Attached red probe with screw-on 4mm test tip

CAT IV 300V

Page 46: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

51

Voltage TestersInstruments

Operating Voltage ACV 12 ~ 1000V, DCV 12 ~ 1000V

Technical Overview

Power Source No Batteries

Certificates IP65, 61243-3:2011-02

Model Specification

Operating Voltage ACV 12 ~ 1000V, DCV 12 ~ 1000V

Technical Overview

Power Source 2 x 1.5V AAA Batteries

Certificates IP65, 61243-3:2011-02

Model Specification

Operating Voltage 6V, 12V, 50V, 110V, 230V, 415V AC/DC

Technical Overview

Power Source 2 x 1.5V AAA Batteries

Certificates IP66, IEC61010-1 , 61243-3:2011-02

Model Specification

CAT III 1000V

CAT III 1000V

CAT III 600V

DUSPOLA• Analogue Plus• Dust and waterproof• Vibration• Phase sequence• LED indicators• Solenoid movement• Polarity test

DUSPOLE• Expert• Dust and waterproof• Vibration• Phase sequence• Continuity with buzzer• LED indicators• Measuring point illumination• Polarity test

TCV6• Voltage Tester• Dust and waterproof• Voltage indication with LED

Page 47: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

52

Compliance Testers - Selection GuideInstruments

ELECTRIC SAFETY MEASUREMENTS MACROG3 T419 T60

PAGE 53 53 53

True RMS • • •

Insulation with voltage 50, 100, 250, 500, 1000V DC • • •

Continuity of protective conductors with 200mA / 10A • • •

Tripping time and current of RCDs type B, A, AC Standard, Selective and Delayed up to 1A

200mAOnly A, AC general and

selective200mA

Tripping time and current of earth leakage relaystype B, A, AC Standard, Selective and Delayed up to 10A

•*** •***

Non-trip earth resistance • • •

Earth resistance with rods • •

Earth resistance with stakeless testing method •** •**

Ground resistivity by 4-wire method • •

Loop/Line impedance, Phase-Phase, Phase-Neutral, Phase-PE • • •

Loop/Line impedance Phase-Phase, Phase-Neutral, Phase-PE with high resolution (0.1mΩ)

•* •* •*

Measurement of percentage voltage drop on the line • •

Contact Voltage • • •

Phase Sequence • • •

Leakage current with optional clamp meter • • •

POWER ANALYSIS

Measurement of Voltage, Current, Active, Reactive, Apparent Power (1) •

Measurement of Cosphi, Power Factor (1) •

Voltage and current harmonics up to the 49th with calculation of THD% 25th •

ADDITIONAL CHARACTERISTICS

Safety category CAT III 240V CAT III 240V CAT III 300V

Automatic test (Ra, RCD, Insulation) • •

Measurement of environmental parameters (°C, °CF, %RH, Lux) •* *+

Test with remote lead PR400 • • •

Help on screen display • • •

Internal memory for measured data saving • • •

Optical/USB serial port for PC connection • • •

Integrated WiFi connection and compatibility with HTANALYSIS App • •

Size (L x W x H) mm 222 x 16 2x 57 222 x 162 x 57 222 x 162 x 57

Weight (batteries included) Kg 1.2kg 1.2kg 1.2kg

Reference standard for safety IEC/EN61010-1 IEC/EN61010-1 IEC/EN61010-1

IP degree 50 50 50

* Optional accessory TIMP57** Optional accessory clamp T2100 *** Optional accessory RCDX10 (1) Single-phase or balanced three-phase system+ Optional accessory HT52/05

Page 48: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0

53

InstrumentsCompliance Testers

Power Source 6 x 1.2V type AA rechargeable batteries, 6 x 1.5V type AA alkaline batteries

Standard Accessories3 Terminal cable with SHUKO plug, Set of 4 cables + 4 alligator clips + 2 test leads, TEARTHKIT - Set of 4 cables + 4 metal earth probes, Carrying bag, Windows software + optical/USB cable, PR400 - Switch probe, External battery charger

Optional Accessories USB Cable T2100 Earth Clamp

Certificates Calibration certificate ISO9000, Certificate of Conformance

Model Specification

Power Source 6 x 1.5V batteries type AA

Standard Accessories Test leads, Carry case, English Instruction Manual

Optional Accessories TOPVIEW Software and USB Cable

CertificatesIEC/EN61010-1. IEC/EN61557-1-2-3-4-6-7, Calibration Certificate ISO9000, Certificate of Conformance

Model Specification

http://www.hellermanntyton.co.za/downloads.html

Application video

http://www.hellermanntyton.co.za/downloads.html

Application video

http://www.hellermanntyton.co.za/downloads.html

Application video

CAT III 240V

CAT III 240V

TRMS

CAT IV 300V

Power Source 6 x 1.2V (rechargeable) AA or 6 x 1.5V AA batteries or 10W power supply

Standard Accessories

HTFLEX33E 4pcs 3000A AC flexable clamps 174mm, C2033X - 3 Banana to shuko plug cable, UNIVERSALKITG3 - Set of 4 cables, KITTERRNE - 4 earth rods and cables in bag, PR400 - Remote switch , PR400 - Stylus, BORA2051 - Soft carry bag, TOPVIEW 2006 - PC softwre & optical-USB connection cable, Hands free kit

Certificates IP 40. EN61010-1, EN61326-1, EN61557-1-2-3-4-5-6-7-10, EN50160, EN60909-0

Model Specification

MACROG3 (23kA L-N) (40kA L-L)Advanced multifunction device for verification of electric safety of domestic and industrial electric systems (IEC/EN61557-1)

• Compliance Tester• Earth resistance by voltammetric method with 2 or 3 poles in TT, TN and IT systems,

non-trip earth resistance measurement and earth resistance with stakeless testing method with clamp meter T2100 (optional). Ground resistivity

• Measurement of electric parameters in single-phase installations (V, I, W, VAR, VA, PF)

• Test of RCDs type A, AC, B up to 1A, earth leakage relays with test current up to 10A (with optional accessory RCDX10)

• Measurement of insulation resistance• Touch-screen colour

T419 (23kA L-N) (40kA L-L) Multifunction device for tests on domestic and industrial systems

• Compliance Tester• Continuity of protective conductors with 200mA• Insulation with 50, 100, 250, 500, 1000VDC• Loop/Line impedance P-N, P-P, P-PE also with high resolution (0.1mΩ) with optional

accessory IMP57• Non-trip earth resistance• Phase sequence rotation• Memory storage of results• Optical/USB interface for PC connection• Global Earth Resistance

T60 Compliance/3-Phase Power Analyser• 362 Parameters over 2 months• Voltage anomalies (sags and swells)• Real-time display of wave forms • Earth resistance 2 or pole• 4 pole soil resistivity method • RCD type testing, A, AC, B up to 10A• Insulation resistance up to 1000V• Advanced loop testing of MCBs• WiFi connectivity• Power factor• THD (Total Harmonic Distortou) 49th Harmonic• Verification of phase sequence and leakage currents

TRMS

TRMS

Page 49: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

54

1.0 Power Analyser - Selection GuideInstruments

*Through App HTANALYSIS **Adapter ACONBIN necessary

MAIN MEASUREMENTS T824 T78 TPQA820

PAGE 55 55 55

AC/DC voltage in single-phase/three-phase systems • • •

AC/DC current in single-phase/three-phase systems • • •

Cosphi, Power Factor • • •

Voltage unbalance (NEG%, ZERO%) • • •

Active, reactive, apparent power/energy and DC power • • •

Voltage and current harmonics up to the 49th with THD% • • •

Voltage anomalies (dips, peaks) with 10ms resolution (@ 50Hz) • • •

Voltage fast transients (spikes) with 5µs resolution •

Electric motor starting current (INRUSH) •

Voltage flickers (Pst, Plt) •

Phase sequence • • •

Neutral-Ground Voltage • •

Neutral current • • •

MEMORY AND RECORDING

Max number of simultaneously selectable parameters 251 251 383

Recording with selectable integration period 1s-60n 1s-60n 5s-60s

Indicative memory duration(in days @ PI=10min @ max number of parameters)

90 days 90 days 30 days

Indication of recording duration • • • *

Internal memory capacity 50MB 15MB 8MB

External compact flash card • •

Default and custom recording • •

Saving instant sampled value • • • *

REAL-TIME DISPLAY

Summary table of main electric parameters • • • *

Voltage/current waveforms • • • *

Tables or histograms of Harmonics and THD% • • • *

Voltage/current vector diagram • • • *

ADDITIONAL CHARACTERISTICS

Safety category

Measurement with use of external CT and VT (with optional accessory HT903 • • •**

Touchscreen colour display • •

Power supply and rechargeable battery recharging • •Auto power

supplied

Auto Power Off (APO) • • •

USB port for data download onto Pen Drive • • Only PC

Provided PC interface with software for Windows USB USB WiFi/USB

Context help active on each screen • •

Protection password on recording • •

Size (L x W x H) mm 235 x 165 x 75 235 x 165 x 75 255 x 200 x 115

Weight (batteries included) Kg 1 1 0.7

Reference standard for power quality EN50160 EN50160

Reference standard for safety IEC/EN61010-1 IEC/EN61010-1 IEC/EN61010-1

CAT IV 600V CAT IV 600V CAT IV 300V

Page 50: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

55

1.0Power AnalysersInstruments

T78• 3-Phase Power Quality Analysers• 251 Simultaneous parameters on single-phase and 3-Phase 3-wire

and 4-wire systems• 5 Input channels for voltages and 4 input channels for currents• Numerical and graphic display (waveforms)• Recording of voltage anomalies (dips, peaks) with 10ms resolution• Up to 49 Harmonic power factor• Colour touch-screen

TPQA820• 3-Phase and single-phase power quality analysers• WiFi• Max 415 between inputs• AC TRMS voltage in single-/3-Phase systems• AC TRMS current in single-/3-Phase systems• Vibration• Calculation and recording of voltage/current THD%• iPad Mini

http://www.hellermanntyton.co.za/downloads.html

Application video

iPad Mini (Wi-Fi only supplied with product)

Power Source Rechargable Lithium-Ion battery

External Power Source 100 ÷ 415V, 50/60Hz

Operating Temperature 0 to 40°C

PC interface USB 2.0 and WiFi

Certificates IP65, IEC61010-1. Certificate of Conformance

Model Specification

http://www.hellermanntyton.co.za/downloads.html

Application video

Power Source1 x 3.7V rechargeable Lithium-Ion battery, with external adapter, duration >3h, auto power off after 5 minutes’ idling

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

Power Source1 x 3.7V rechargeable Lithium-Ion battery, with external adapter, duration >3h, auto power off after 5 minutes’ idling

Certificates UL, IEC61010-1. Certificate of Conformance

Model Specification

CAT III 600V

CAT III 600V

CAT IV 300V

T824 • 3-Phase Power Quality Analyser and Recorder• Simultaneous measurement of power parameters on single-phase

and 3-Phase 3-wire and 4-wire systems• 5 Input channels for voltages and 4 input channels for currents• Numerical and graphic display (waveforms)• Recording of voltage anomalies (dips, peaks) with 10ms resolution

TRMS

TRMS

TRMS

Page 51: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

56

ACCESSORY T824 T78 TPQA820

PAGE 55 55 55

TOPVIEW2007 PC Windows software + USB cable

• • •

BORSA2051 Soft carrying bag for device/accessories

O O

A0055 External power supply AC/DC

• •

KITMPPACC Set of 4 alligator clips for AC voltage

KITMPPACW Set of 4 cables for AC voltage 2m

TKIT800 Set of 5 cables, black, Red, green, Blue and brown with alligator clips

• •

606-IECNConnector with magnetic terminal

O O •

ACONBIN Adapter for connection standard clamps

O

HTFLEX33E Flex 3000A AC clamp, max diameter of cable 174mm

• •

TFLEX33L Flex 1000A AC clamp, diameter 174mm

HTFLEX35Flex 3000A AC clamp, max diameter of cable 274mm

O O O**

HT96U Standard AC clamp 1-100-1000A/1V, diameter 54mm

O O O*

HP30D1 Standard DC clamp 1000A/1V, diameter 83mm

O O O*

HT4005K Standard AC 200A/1V clamp, diameter 40mm

O O O*

HT4005N Transducer AC 5A-100A/1V

O O O*

O Optional* Adapter ACONBIN necessary** Max measurement 1000A AC

1.0 Power Analyser Accessories- Selection GuideInstruments

Page 52: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

57

ACCESSORY T824 T78 TPQA820

PAGE 55 55 55

TOPVIEW2007 PC Windows software + USB cable

• • •

BORSA2051 Soft carrying bag for device/accessories

O O

A0055 External power supply AC/DC

• •

KITMPPACC Set of 4 alligator clips for AC voltage

KITMPPACW Set of 4 cables for AC voltage 2m

TKIT800 Set of 5 cables, black, Red, green, Blue and brown with alligator clips

• •

606-IECNConnector with magnetic terminal

O O •

ACONBIN Adapter for connection standard clamps

O

HTFLEX33E Flex 3000A AC clamp, max diameter of cable 174mm

• •

TFLEX33L Flex 1000A AC clamp, diameter 174mm

HTFLEX35Flex 3000A AC clamp, max diameter of cable 274mm

O O O**

HT96U Standard AC clamp 1-100-1000A/1V, diameter 54mm

O O O*

HP30D1 Standard DC clamp 1000A/1V, diameter 83mm

O O O*

HT4005K Standard AC 200A/1V clamp, diameter 40mm

O O O*

HT4005N Transducer AC 5A-100A/1V

O O O*

1.0Photovoltaic Instrument - Selection GuideInstruments

MAINTENANCE AND EFFICIENCY OF THE PHOTOVOLTAIC SYSTEM

SOLARIV IV500 SOLAR300N PVCHECK

PAGE 61 61 62 62

Continuity of protective conductors with 200mA •

Insulation measurement with test voltage 250, 500, 1000V DC with no service interruption

I-V Curve measurement on single module or string •

VOC and ISC measurement on single module or string

• •

Single-Phase and Three-Phase efficiency measurement

1MPPT 1MPPT

DC side ef ciency of the photovoltaic field • •

Use of remote unit SOLAR02 with USB \ RF connection

RF USB RF

Measurement of irradiation with reference cell • • • •

Temperature measurement of cell and environment • • • •

POWER QUALITY ANALYSIS

AC/DC voltage in single-phase/three-phase systems • DC

AC/DC current in single-phase/three-phase systems • DC

Cosphi, Power Factor •

Voltage unbalance (NEG%, ZERO%) •

Power/Energy: Active P, Reactive Q, Apparent S Only active P • Only active P

Voltage and current harmonics up to the 49th with THD%

Voltage anomalies (dips, peaks) with 10ms resolution (@ 50Hz)

Voltage fast transients (spikes) with 5µs resolution (200kHz)

Electric motor starting current (INRUSH) •

Voltage flickers (Pst, Plt) •

Full analysis according to EN50160 •

Phase sequence •

Neutral-Ground Voltage •

Neutral current •

MEMORY AND RECORDING

Internal memory capacity249 curves I-V

8 days@ PI =10 min

249 curves I-V15MB

90 days@ PI =10 min

999Locations

Recording with selectable integration period 5s-60m 5s-60m 5s-60m

Indicative memory duration(in days @ PI=10min @ max number of parameters)

8 90

Indication of recording duration for power quality analysis

Internal memory extension with Compact Flash card •

Default and custom recordings •

REAL-TIME DISPLAY

Summary table of main electric parameters • • • •

Voltage/current waveforms •

Tables or histograms of Harmonics and THD% •

Voltage/current vector diagram •

Page 53: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0 Photovoltaic Instrument - Selection GuideInstruments

58

ADDITIONAL CHARACTERISTICS SOLARIV IV500 SOLAR300N PVCHECK

Measuring range of I-V Curve / IVCK1500V/ 10A1000V/ 15A

1500V/ 10A 1000V/ 15A

1000V/15Aonly VOC and ISC

Measuring range for efficiency measurement 1000V DC/ 265V AC1000V AC-DC

3000A

Safety category CAT III 300 CAT III 300 CAT IV 600 CAT III 300

Touchscreen colour display •

LCD display with backlight • • •

USB port for data download onto Pen Drive •

PC interface with software for Windows • • • •

Integrated WiFi interface • •

Custom management of internal PV module database

• • •

Power supply with rechargeable battery and battery charger

Auto Power Off (APO) • • • •

Indication of recording duration for efficiency measurement

• •

Reference standard for Power Quality Analysis EN50160

On display help • • • •

Size (L x W x H) mm 235 x 165 x 75 235 x 165 x 75 235 x 165 x 75 235 x 165 x 75

Weight (batteries included) kg 1.2 1.2 1 1.2

Reference standard for safety IEC/EN61010-1 IEC/EN61010-1 IEC/EN61010-1 IEC/EN61010-1

TroubleshootingIf system efficiency is lower than expected, it is necessary to detect the defective modules so that they can be replaced. This can be achieved by measuring the I-V curve with devices SOLARIV and IV500.

Solutions for Performance and TroubleshootingCommissioning TestsWhen operating a photovoltaic system, it is necessary to certify its safety according to IEC62446. The suitable device to carryout these verifications is PVCHECK.

PerformanceSystem performance monitoring it is possible to detect production loss quickly and efficiently. SOLAR300N and SOLARIV can record the energy production of a system and the inverter performance check over time thus preventing unneccessary maintenance.

ºC

W/m2

ACDC

KwhKwh

COMBINERBOX

SOLARIVIV500

SOLAR300NSOLARIV

Three-phaseSingle-phase

PVCHECK

MAINS

LOADSINVERTER

Page 54: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0Photovoltaic Instrument Accessories - Selection GuideInstruments

59

ACCESSORY SOLARIV IV500 SOLAR300N PVCHECK

PAGE 61 61 62 62

TOPVIEW2006TOPVIEW2007PC Windows software+ USB/ optical cable

TOPVIEW2006 TOPVIEW2007 TOPVIEW2006

PT300N PT1000 probefor PV module tempera-ture

• • O

SOLAR02Remote unit for Irradiationand Temperature

• O • O

KITGSC4 Set of 4 cables+ 4 alligator clips

• • •

KITPVMC3 - KITPCMC3Set of 2 adapterswith connectors MC3

KITPVMC3 KITPVMC3 KITPCMC3

KITPVMC4 - KITPCMC4Set of 2 adapters with connectors MC4

KITPVMC4 KITPVMC4 KITPVMC4

TKIT800 Set of 5 cables+ 5 alligator clips

A0055External power supply AC/DC battery charger 230V 50/60Hz

PT400Touch-screen pen

HT304NSensor for irradiation measurement

• • • O

M304Mechanical inclinometer

• • O

HT4004NStandard 10-100A DC clamp, diameter 32mm

• •

O Optional

Page 55: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

ACCESSORY SOLARIV IV500 SOLAR300N PVCHECK

PAGE 61 61 62 62

HT4005KStandard 200A AC clamp,diameter 40mm

• •

C2007USB cable

BORSA2051Soft carrying bag

VA500Rigid carrying case

• • •

HT97UStandard clamp 10-100-1000AAC, diameter 54mm

O O

HTFLEX33EFlex 3000A AC clamp,diameter 174mm

O

HP30D1Standard 1000A DC clamp,diameter 83mm

O O

HP30C3Standard 3000A AC clamp,diameter 70mm

O

HP30C2Standard 200-2000A ACclamp, diameter 70mm

O

606IECNMagnetic connectorsfor voltage measurement

O O O

O Optional

60

1.0 Photovoltaic Instrument - Selection GuideInstruments

Page 56: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

61

1.0Photovoltaic InstrumentsInstruments

Power Source 6 x 1.5V AA Alkaline batteries

Model Specification

Power Source 6 x 1.5V AA Alkaline batteries

Model Specification

Measuring of curve IV with environmental sensors Measuring single-phase efficiency with remote environmental sensors

* Measuring a IV curve via remote synchronisation of irradiation and temperature Measuring of curve IV with environmental sensors

CAT III 300V

CAT III 300V

SOLARIVDevice for tests and maintenance of single-phase installations

• Measurement of efficiency of a single-phase photovoltaic system• Measurement of I-V Curve of a module or of a string• Measurement of open-circuit voltage and of short-circuit current Voc/Isc• Database of 30 000 selectable photovoltaic modules• Measurement of PV module/string output voltage up to 1500V DC• Measurement of PV module/string current up to 10A DC• Measurement of resistance of series Rs of panels• DC/AC TRMS single-phase voltage• DC/AC TRMS single-phase current• * Measuring a IV curve via remote synchronisation of irradiation and temperature. Refer to IV500.

IV500Device for maintenance and troubleshooting

• Measurement of open-circuit voltage and of short-circuit Vos/Isc• Measurement of PV module/string output voltage up to 1500V DC• Measurement of PV module/string output current up to 10A DC• Direct comparison with reference conditions (STC - 1000Wm2 25°C) • Internal memory for data saving

ºC

PT300N

W/m2

SOLARIV

IV500

HT304NPT300N

ºC W/m2

IV500

RF Synchro

HT304NPT300N

SOLARIV

ºC W/m2

RF Synchro

SOLAR02

ºCW/m2

HT304NPT300N

LOADS

AC DCMAINS kWhkWh

SOLARIV

INVERTER

Page 57: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

62

1.0 Photovoltaic InstrumentsInstruments

PVCHECKEarth

Connection diagram 3-Phase System

CAT III 600V

Power Source 6 x 1.5V AA Alkaline Batteries

Model Specification

HT304N

SOLAR02

CAT III 300V

“Whole photovoltaic field“ insulation measurement method Measuring efficiency of photovoltaic field

SOLAR300NDevice for vertification of single-phase and 3-Phase PV system efficiency and power quality analysis in compliance with standard EN50160

• Verification of the efficiency of photovoltaic system• Analysis of power quality and energy consumption• DC/AC TRMS voltage (single-phase and 3-Phase)• DC/AC current (single-phase and 3-Phase)• DC/AC active power (single-phase and 3-Phase)• Power factor cosj (single-phase and 3-Phase)• Solar radiation• Panel and environment temperature• Display of testing result (OK/NOT OK)• Remote unit SOLAR02 for measuring irradiation and temperature• Periodic recording of power parameters with programmable PI• Analysis of recordings• Voltage anomalies and spikes

PVCHECK and PVCHECK PRODevice for commissioning tests of electric safety and performance

Automatic test in a sequence of: • Measurement of insulation up to 1000VDC• Open-circuit voltage and short-circuit current Voc/Isc• Continuity of protection conductors with 200mA• Internal memory and USB output for PC Connection• Efficiency measurements of the photovoltaic system• Efficiency measurement of the photovoltaic field (DC side)

Code Description

SOLAR02 Remote unit to record irradiation and temperature

HT304NKit of 5 cables + alligator clips for voltage measurement Sensor for irradiation measurement

PT300N Probe PT1000 for panel temperature

PVCHECK PRO

SOLAR02

Synchronisedwith SOLAR300N

ºCW/m2

HT304NPT300N

AC DC

kWh kWh

SOLAR300N

INVERTERMAINS

LOADS

LOADS

MAINS kWhkWh

PVCHECK

INVERTER

SOLAR02

HT304N

ºCW/m2

RF Connection

PT300N

Page 58: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

63

1.0CalibratorsInstruments

DC voltage (generated and measured)

Range 0.01mV ÷ 10V

Resolution 0.01mV ÷ 0.001V

Accuracy ±(0.02%rdg + 4dgt)

Protection 30VDC

DC current (generated and measured)

Range I0.001mA ÷ 24mA

Percentage -25% ÷ 125%

Resolution 0.001mA

Accuracy ±(0.02%rdg + 4dgt)

Protection 30mADC

DC voltage (generated and measured)

Slower linear ramp from 0% 100% 0% in 40s

Faster Linear ramp from 0% 100% 0% in 15s

Step ramp from 0% 100% 0% in steps of 25% with rampsof 5s each

Technical Overview

Standard AccessoriesTest Leads, Alligator Clips, Protection Rubber Holster, Lithium-Ion Rechargeable Battery, External Adapter, User Manual, Carrying Case

Model Specification

Output Measuring Range

Output Range Resolution Accuracy Remark

DCV

100mV1000mV10V

-10.000mV to 110.000mV-100mV to 1100mV-1.0000 to 11.0000V

1µV10µV0.1mV

0.02 + 0.010.02 + 0.010.02 + 0.01

Max ouput current: 0.5mA Max ouput cur-rent: 2mA Max ouput current: 5mA

DCA 20mA 0.000mA to 22.000mA 1µA 0.02 + 0.02 Max load 1kΩ at 20mA

Resitance400Ω4kΩ40kΩ

0.00Ω to 400.00Ω0.0000kΩ to 4.0000kΩ0.000kΩ to 40.000kΩ

0.01Ω0.1Ω1Ω

0.02 + 0.020.05 + 0.0250.1 + 0.1

Current 0.5 to 3mACurrent 0.05 to 0.3mACurrent 0.01mA

Temperature

RSBEKJTN

-0ºC to 1767ºC-0ºC to 1767ºC600ºC to 1820ºC-200ºC to 1000ºC-200ºC to 1372ºC-200ºC to 1200ºC-250ºC to 400ºC-200ºC to 1300ºC

1ºC1ºC1ºC0.1ºC0.1ºC0.1ºC0.1ºC0.1ºC

1.5ºC1.5ºC1.5ºC0.6ºC0.6ºC0.6ºC0.6ºC1.0ºC

ITS-90 temperature scale: The accuracy does not include the error of internal temperature compensation caused by a sensor

RTD

PT100-385PT200-385PT500-385PT1000-385

-200ºC to 800ºC-200ºC to 630ºC-200ºC to 630ºC-200ºC to 630ºC

0.1ºC0.1ºC0.1ºC0.1ºC

0.3ºC0.8ºC0.4ºC0.2ºC

Temperature scale ITS-90. Current varies from 0.5 to 3mA. Does not inculde lead resistance

Frequency

100Hz 1kHz10kHz100khz

1Hz to 110.00Hz0.100kHz to 1.10kHz1.0kHz to 11.0kHz10kHz to 110kHz

0.01Hz1Hz0.1kHz2kHz

2 count2 count2 count2 count

Output voltage 1 to 11Vp-pAmplitue accuracy 5% + 0.5VMax load > 100kΩDuty cycle 50%

Pulse100Hz1kHz10kHz

1 to 100000 cycles1 to 100000 cycles1 to 100000 cycles

1 cycle1 cycle1 cycle

2 count2 count2 count

Switch100Hz to 100kHz

1Hz to 110kHz 0.1Hz to 2kHz

5 count Max open/close voltage 28V and 50mA

Technical Overview

Power Source 1 x 9V Battery

Model Specification

T8051• Process Calibrator• Generation of output voltage signal with amplitude up to 10VDC• Voltage measurement up to 10VDC• Generation of output current signal with amplitude up to 24mADC• Current measurement up to 24mAVDC• Current measurement under percentage format (4-20mA)• Adjustment selector with high sensitivity• Up to 3 available automatic ramp selection

T123 • Process Calibrator• Only for sourcing and not for input voltages

Page 59: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

64

1.0 Test LeadsInstruments

CAT IV 1000V

CAT IV 600V

CAT III 1000V

T02AS• Universal • Suitable for all testers with 4mm terminals• Budget test lead set with probe and crocodile clips• Silicon based

TAL24• Universal• Suitable for all DMM’s• 2mm Probe tip• PVC test leads• C/W crocodile clips• Screw on crocks

TALTBM• Silicone• IEC61010-1• Ideal for TBM SEE PG 13-18 meters

TAL25 • Universal• Suitable for all DMM’s• 4mm Probe tip• PVC test leads• C/W crocodile clips• Slide on crocks

TAL35RBK• Silicone• General Multimeter use• Double insulated Silicone wire (1m)• Spring-shrouded 4mm brass caged

banana probe tips• Shrouded right-angle connector• IEC1010

T8040LEAD• Universal • Suitable for all Toptronic and Fluke 70 series• Budget test leads

Page 60: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

65

1.0Test LeadsInstruments

CAT III 1000V

TALTIN • Double insulated silicone wire (1.2m)• Used for TIN insulation testers

TIN4D - SEE PG 38 TIN5D - SEE PG 39 TIN6A - SEE PG 39 TIN6D - SEE PG 39 TIN7D- SEE PG 40

TAL30CRBK• Accessories• Wide grip crocodile clip with integral finger guard• Suitable for use with TAL35RBK test leads• Compatible with 4mm male leads

TAL30ARBK• Silicone• Double insulated silicone wire (1m)• Wide grip crocodile clips with integral finger guard• IEC1010• Straight shroud terminations

TAL1825• Accessories• Short length to reduce resistance

with loop test• Used for loop testers T1825 - SEE PG 41

TAL38CRBK• Accessories• Wide grip crocodile clips with integral finger guard• Suitable for all 4mm male leads• Suitable for use with TAL39RBK test leads

TAL39RBK• Silicone• Double insulated silicone wire (1.2m)• Straight shroud terminations both sides

Page 61: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0 Test LeadsInstruments

66

Colour Size

Red 15m

YELLOW 10m

BLACK 10m

GREEN 5m

Colour Size

Red 30m

YELLOW 20m

GREEN 5m

Accessories Earth bar, Alligator clip

TKPS54BK /TKPS54RD• Accessories• Flexible shaft with twin pointed gripping jaws

Colour: RD - Red BK - Black

• Compatible with 4mm male leads

TAL36• Wide grip alligator clips with 35mm spring mouth• PVC insulated wire

TELEWR50F• 4mm Brass banana plug• Soft PVC insulated wire• 50m braided copper wires

TEARTHKIT• Used for earthing testers

T416 - SEE PG 31 MACROG3- SEE PG 53 T60 - SEE PG 53

TAL36L• For 3-wire earth resistance test• Wide grip alligator clips with 35mm spring mouth• PVC insulated wire

Page 62: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0Cable Avoidance DetectorsInstruments

67

VSCAN• Compass (cable avoidance detector)• Self-test and calibration verification• Metal cover locating mode• Lithium ion rechargeable batteries• Internal or external GPS• Rotary control for sensitivity• Depth and current measurement (configurable)• Bluetooth• 1 Watt • 33kHz and 131kHz simultaneously applied by direct connection,

induction or optional induction clamp

VSCANM• Cable avoidance detector• Self-test and calibration verification• Metal cover locating mode• Lithium ion rechargeable batteries• Rotary control for sensitivity• Depth and current measurement (configurable)• 33kHz and 131kHz simultaneously applied by direct connection,

induction or optional induction clamp

LPC - Live Plug ConnectorThe LPC separation filter is used to inject and locate frequency into a live cable via a domestic power socket to trace the services from the building to the connection in the street. Between 100 V AC and 250 V AAC

Page 63: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

68

1.0 Cable Route TracersInstruments

Sensitivity Max depth

Dynamic Range SL, DL, DLG, PL, PLG, TL and TLG

Depth in Power PL, PLG

Technical Overview

CAT4PLUS The C.A.T4 Avoidance ModeTM searches for power, radio and Genny4 signals, and pinpoint located utilities, in a single scan. The bargraph ‘tidemark’ enables the user to quickly spot and zero-in on a buried conductor.

• Cable And Pipe Locator• eCert™ – remote calibration validation to form part of an annual service regime• Avoidance instrument, not cable fault locator• Provides four functions, audio and visual indication and depth estimation in

genny mode• Signal strength indicator• Mode/clockface indicator

The Genny4 transmits a specialised small diameter Locate frequency which facilitates location of utilities such as telecoms and street lighting, including spurs. C.A.T4’s Dynamic Overload Protection feature automatically filters out high levels of interference, eg. electrically noisy areas such as substations and under high-voltage cables.

Avoidance ModeTM

Avoidance Mode speeds the process of pre-digital scanning by searching for power, radio and Genny signals simultaneously.

RD7100• Excavation of buried utilities easier and safer• Simultaneous depth and current readout• Dynamic overload protection• Power filtersTM

• TrudepthTM

• Guidance mode• Automatic usage-logging with GPS positioning• ECERTTM - Remote calibration without downtime• Ingress protection for tough environments (IP65)

VLOCPRO2• Rugged ABS and carbon fibre construction• IP54 rating for all weather use• Colour display• High speed dual core processor• Multiple location modes with compass orientation• Multiple frequencies (over 70 are pre-programmed)• Push button and continuous depth/current (feet or meters)• Rechargeable and alkaline battery packs• Combined GPS location with locate data (such as depth, current, etc.)

Power Source Alkaline, NiMH or Li-Ion

Standard Accessories TX-1, RX

Model Specification

Page 64: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

69

1.0High Voltage TestersInstruments

Telescopic Hot Stick - Hastings

VTT25F • 6 Sections• 7.78m (25ft) Length when extended• Voltage range 1 to 132kV• Rubber hook latch• Base cap for better stability • Triangular design for easy operation

VTT30F• 7 Sections• Suitable for voltage ranging 1 to 132kV• Rubber hook latch• Base cap for better stability • Triangular design for easy operation

C4031601 (SH250)• Voltage range 1 to 132kV

CSH230 (SH230)• Voltage range 1 to 132kV

Length Extended 7.78m (25ft)

Standard Accessories Heavy Duty Carry Bag

Certificates

Certificate of ConformanceASTM F 1826-00 specification

Model Specification

Length Extended 7.62m (25ft)

Standard Accessories Heavy Duty Carry Bag

Certificates Calibration Certificate

Model Specification

Length Extended 9.18m (30ft)

Standard Accessories Heavy Duty Carry Bag

Certificates

Certificate of ConformanceASTM F 1826-00 specification

Model Specification

Length Extended 9m (30ft)

Standard Accessories Fuse Hook, Bag

Certificates Calibration Certificate

Model Specification

T99FD - Fuse disconnect included

Telescopic Hot Stick - Ritz

Page 65: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

70

1.0 High Voltage TestersInstruments

THS25F• Triangular - shaped design keeps sections aligned during extension and retraction• Withstands voltage rating of 100kV from 30cm for 5min• Universal end fitting

THS30F• Triangular - shaped design keeps sections aligned during extension and retraction• Withstands voltage rating of 100kV from 30cm for 5min• Universal end fitting

Length Extended 7.78m

Standard AccessoriesDisconected hook and carry bag

Sections 6

Certificates IEC 62193

Model Specification

Length Extended 9.18m

Standard AccessoriesDisconected hookand carry bag

Sections 7

Certificates IEC 62193

Model Specification

TPCAA90 - 90º Angle bends for the TPC Series (Optional Accessory)

ELECTRICAL

Model TPC7K TPC11K* TPC22K TPC33K* TPC44K

System Voltage (kV) 6.6 11 22 33 44

Full Scale Voltage (kV) 8 12 24 36 48

Total Resistance (MΩ) 3.95 6.78 13.5 20.1 27

Response Time 1 Second

Neon Threshold 1.2 kV

MECHANICAL

Total Length (m) 1.105 1.105 1.225 1.375 1.525

Total Weight (kg) 1.2 1.2 1.3 1.4 1.5

Operating Temperature -25˚C to 55˚C

Operating Humidity 20 to 96% RH

Standard Accessories Carry Case, Instruction Manual, IEC Certificate

Optional Accessories 90˚ Bend TPCAA90

Certificates IEC61481:200, IECSPE8561481

Note: * - Standard stock items.

Technical Overview

Telescopic Hot Sticks

TPC7/11/22/33/44K• High Voltage Phase Comparators/Live

Line Tester/Voltage Detector• No user assembled parts• Dual colour coded scale (%, Vac)• Neon indicator lit when > 1200 Vac• Measure and test phase to earth

phase to phase• High quality fibreglass wound rod

• Self powered operation - no battery• Current is limited to Milliampere• Grounded or ungrounded systems• Lightweight, robust and compact• High immunity to interference fields• Silcone handles• Specified by town councils

Page 66: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

71

1.0High Voltage TestersInstruments

Wireless Receiver

Wireless Transmitter

Technical Overview

System Voltage (kV) 11 to 33kV

Threshold Range (kV) 1.3kV

Response Time < 1 second

Spark ProtectionThe detector will not be damaged as a result of spark discharge while making contact with the conductor under test

Bridging ProtectionThe comparator and its accessories will not cause flashover between live parts of the installation or between live parts of the installation and earth/ground

Current Consumption 45 mA maximum

Range 30m in air

Visual Indicator Transmitter - 2 x Red LED’s / Receiver - 1 x Red LED + 1 x Green LED

Audible Indicator Buzzer present when IN Phase is indicated - > 65dB (5 metres)

MECHANICAL

Length(mm) Diameter (mm) Material

Y Electrode 35 40 Stainless steel

Hook 100 40 Stainless steel

Dimensions (mm) 180 (L) x 100mm (Dia.)

Weight 600g

Power Source 1 x 9V Battery

Standard Accessories Carry case, Cleaning Kit, 2 x Rose Connector, 2 x Y Contact, 1 x Hook

Certificates Certificate of Conformance IEC 61481

Model Specification

Technical Overview

MODEL T11338VD25E

System Voltage 11/33kV

Threshold Set within Range 1.65kV to 14.6kV

Response Time <1 Sec

Auto-OFF ±3 Min

Bridging Protection Yes

Spark Protection Yes

Battery Low <7V

Threshold 2.5kV

Battery Current <30mA

Green = Armed Yes

Red = V Detected Yes

WPC• Series High Voltage Wireless Transmitter Receiver Phasing Comparator

WPC1000 - 11kV-33kV Voltage range (As shown on this page)WPC3000 - 44kV-132kV Voltage range

• Wireless distance up to 200 metres• All weather use (indoor or outdoor)• Conductor is energised or de-energised to detect and indicate the correct phase

relationship between 2 enegised lines nominal voltage and frequency• IN phase or OUT of phase

T1133HVD25E• Designed for multi-voltage sites• Covers systems voltage from 11kV to 33kV

Page 67: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

72

1.0 High Voltage TestersInstruments

Technical Overview

MODEL T213HVD T217HVD T218HVD T219HVD T220HVD T222HVD

System Voltage 11kV 11/33kV 6/22kV 44/132kV 6.6/132kV 11/44kV

Threshold Set within Range

1.65kV to 4.4kV

3.3kV to 4.95kV

1.8kV to 2.7kV

6.6kV to 19.8kV

1.65kV to 14.6kV

4.4kV to 5.0kV

Response Time <1 Sec <1 Sec <1 Sec <1 Sec <1 Sec <1 Sec

Auto-OFF ±3 Min ±3 Min ±3 Min ±3 Min ±3 Min ±3 Min

Bridging Protection Yes Yes Yes Yes Yes Yes

Spark Protection Yes Yes Yes Yes Yes Yes

Battery Low <7V <7V <7V <7V <7V <7V

Threshold 3.02kV 4.12kV 2.5kV 13.2kV 2.5kV 4.75kV

Battery Current <30mA <30mA <30mA <30mA <30mA <30mA

Green = Armed Yes Yes Yes Yes Yes Yes

Red = V Detected Yes Yes Yes Yes Yes YesLIFETIME WARRANTY

HVD• High Voltage Detector• Checks if HV system is alive or dead• All weather use (indoor or outdoor)

THVD • Contact Capacitive High Voltage Detector• Self starting and automatically activated when the High Voltage is applied to the

contact electrode• Use on sinusoidal (50 or 60Hz) High Voltage Systems• Models are available to cover systems voltage from 6.6kV to 132kV• IEC 61243-1 for voltages above 1kV 50/60Hz• Check system is dead or alive

Spark Protection The detector will not be damaged as a result of spark discharge

while making contact with the conductor under test

Bridging Protection The detector and its accessories will not cause flashover between live parts of the installation or between live parts of the installation and earth/ground

Current Consumption 30 mA maximum

Test Button Tests and arms the detector when pressed and released

Visual Indicator (2Hz) Red lamp (voltage present), green lamp (safe)

Audible Indicator Buzzer - 3.1 kHz tone modulated at 2 Hz - 70 dB (1.5 metres)

Mechanical

Length(mm) Diameter (mm) Material

Y Electrode 35 40 Stainless steel

Standard Accessories Carry bag, Cleaning kit, Rose Connector, Y Contact

Technical Overview

ELECTRICAL HVD13AC HVD32AC HVD33AC

System Voltage (kV) 6.6 to 132 11 to 33 44 to 132

Threshold Range (kV)

2.5kV 2.5kV 10kV

Non standard threshold voltages can be set outside the range to suit customers requirements

Page 68: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

73

1.0High Voltage Testers and Automotive TestersInstruments

Ranges 240V, 3.3kV, 6.6kV, 11kV, 22kV, 33kV, 66kV, 132kV, 275kV

Detection Selection range is detected at approx. 25cm from the voltage

240V ±10cm, 33kV ±50cm

Self-Test Selection

Indicators Bright Red LED and buzzer

Technical Overview

Power Source 3 x 1.5V C Batteries

Standard Accessories Carry Pouch

Certificates Certificate of Conformance

Model Specification

VOLTAGE RANGE 6-50V

WARNINGNot for use on circuits exceeding 50 Volts

VOLTAGE RANGE 5A/50V

WARNINGNot for use on circuits exceeding 50 Volts.When using a multimeter, voltages from 0-50V can be measured. 5A MAX Rating.

T175HP (High-Prox)• Proximity Detector• Non-contact high voltage detector• Ten switch-selectable voltage sensitivity ranges• Lightweight• Audible and visual indication of live voltage• Rose adaptor • Check high frequency radiation

CBTL - Circuit Buddy 6 to 50• Volt Test Light• Automotive industry• Test for current on wiring, fuses etc • Safe and easy to use, especially when piercing wire• Use of LED’s instead of globes reduces the risk of damage to electronics

CBSPK - Circuit Buddy Safety Probe Kit(To be used with a digital multimeter)

• Automotive industry • Used with a standard multimeter• Easy and safe to pierce wires

Page 69: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

74

1.0 Automotive TestersInstruments

Power Source 1 x 9V Battery

Standard Accessories RJ45 Cable, Case

Certificates Certificate of Conformance

Model Specification

T185• LAN Tester• LED Display• Network cable testing (RJ45)• Test any unenergised wire or cable• Auto and manual scan function• Lock status function• Verify cable continuity, open, short circuit and miss-wired• Buzzer sound warning for wire status

T5012• Carcheck• DC only• Polarity (LED display)• 3 - 48 Volts

Page 70: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

75

1.0Tachometer TestersInstruments

Power Source 4 x 1.5V AA Batteries

Standard AccessoriesReflecting Tape Marks (600mm), RPM Adaptor (cone), RPM Adaptor (Funnel)Surface Speed Test Wheel

Model Specification

Power Source 4 x 1.5V AA Batteries

Standard AccessoriesCarry Case, Reflecting Tape Marks (600mm), RPM Adaptor (cone)RPM Adaptor (Funnel), Surface Speed Test Wheel

Model Specification

Power Source 4 x 1.5V AA Batteries

Standard Accessories Cables with plugs, Sensing Probe, Magnetic Base, Carrying Case, Vibration Probe

Certificate Certificate of Conformance

Model Specification

Technical Overview

Measurement and Range Photo: 2.5 to 999999 RPMContact: 0.5 to 19999 RPMSurface Speeda (m/min): 0.01 to 99.99 m/min

Resolution RPM M/Min

0.1 (0.5 to 999.9 RPM)0.01 (0.05 to 99.99 m/min)

Display 5 Digits, 18mm LCD

Accuracy ±(0.05% + 1 Digit)

Technical Overview

Measurement and Range Photo: 5 to 99.999 RPMContact: 0.5 to 19.999 RPMSurface Speed (m/min): m/min: 0.05 to 1999.9 m/min

Resolution RPM M/Min

0.1 (0.5 to 999.9 RPM)1 RPM (≥ 1000 m/min), 0.01 m/min (< 100 m/min.)

Display 5 Digits, 18mm LCD

Accuracy ±(0.05% + 1 Digit)

TAS35CSurface Speed Test Wheel

TMTL35AMetal Shaft of Cone

TAS35BRPM Adaptor (Funnel)

TA535ARPM Adaptor (Cone)

Feature Parameter Accuracy

Velocity 0.5 ~199.9mm/s ±5%+2 Digit @23 ±5°C

Acceleration 0.5 ~199.9m/s2

Frequency Range 10hz ~1khz

Min and Max Memory

Sampling Time Approx.1 Second

Operating Temperature 0°C to 50°C

Operation Humidity

Technical Overview

LIFETIME WARRANTY

T6236 • Digital Tachometer• Low cost• Photo/contact• Removable contact head• Backlit• Memory Last/Max/Min value

T2238• Digital Tachometer• Photo/contact• Microprocessor based• High accuracy• Variable LCD contrast• Holds last reading/recalls max and min

T8202• Vibration• Magnetic probe• Sensing probe

Page 71: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

76

1.0 Digital TimersInstruments

Mounts on bothDin rail and mini rail

Mounts on bothDin rail and mini rail

Live In

LiveLoad Out

Live In Neutral

TIMERGeyser Circuit Breaker

Wiring diagram

Wiring diagram

Live InLive In

Live In (Volt Range: 1V to 250V AC)

Load Out (Max 20 Amps)Additional Contact (Max 20 Amps)

Neutral

Relay OutputN/C N/O COM

TIMER

Circuit Breaker

Inside Lid

Certificates IEC 60669-1, IEC 60669-2-2, IEC 60730-2-7, IEC 60730-1, RCC Certificate

Certificates IEC 60669-1, IEC 60669-2-2, IEC 60730-2-7, IEC 60730-1, RCC Certificate

Certificates IEC 60730-2-7, 60730-1; 60669-1, 60669-2-2 / RCC Certificate

TDDT7• 7 Day Digital Timer (Relay contacts)• Rated Voltage: 220 - 240V AC (50 - 60 Hz)• Relay contacts for various voltage ranges• Max 20A (3500 Watts) - resistive load (geysers, underfloor heating, lights)• Max 10A - inductive load (pool pump, aircon)• Day/Weekly 16 programmable settings• Din rail mounting• 3 Year backup battery• LCD displays real time hour/minute - on/auto/off

TDDGT• 7 Day Digital Geyser Timer (Internal relay)• Rated Voltage: 220 - 240V AC (50 - 60 Hz)• Max 20A (3500 Watts) - resistive load (geysers, underfloor heating, lights)• Max 10A - inductive load (pool pump, aircon)• Day/Weekly 16 programmable settings• Din rail mounting• 3 Year backup battery• LCD displays real time hour/minute - on/auto/off

TGTLC • Day Digital Geyser Timer (Internal relay)• Pre-programmed timer• Rated voltage 220 - 240V AC (50 - 60HZ) internal relay contact• Six preset times with peak demand lock out between

6:00 - 8:00AM and 18:00 - 20:00PM• Override option up to 2 hours on any program selection including peak

demand if required• 2 Program options out of peak demand• Time and date preset + 2Hr GMT (South Africa)• Weekend mode option• Max 20A (3500 Watts) (resistive loads geysers)• 1 Year backup battery • Time limit drift under 3 min/year• Din rail mounted • Mini rail adaptor (DINADAPT) • Electrostatic, Electromagnetic field immunity certification

Page 72: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

77

1.0Digital TimersInstruments

Certificates IEC 60730

Certificates IEC 60730

TDT7• Digital 3 Pin Socket• Ideal for household use• Backup rechargeable battery • 8 Group programmable• 3500 Watt / 16 Amps

TMT2• 24 Hour Mechanical 3 Pin Socket• Ideal for household use• User friendly• 15 Minute increment adjustment• 3500 Watt / 16 Amps

TMDT2 • 24 Hour Mechanical Din Rail• 15 Day battery back-up• Ideal for household use in DBs• 15 Minute increment adjustment• 3500 Watt / 16 Amps

Page 73: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

78

1.0 Thermometer - Selection GuideInstruments

FEATURE T3004 T8000 T500K T502KJ TIR9PEN T306 T151 T685

PAGE 79 80 80 81 81 81 82 82

Temperature Range-27°C to

60°C-100°C to 1300°C

-200°C to 1372°C

-200°C to 1370°C

-33°C to 500°C

-50°C to 700°C

-30°C to 650°C

-50°C to 1000°C

Probe/Sensor TypeSemi-

conductorK K K, J IR IR IR IR

Single/Dual Input Single Single Dual

Data Hold • • • • • • • •

Min/Max Display • • Max • • • • •

Resolution 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C 0.1°C

Backlight • • • • • •

High/Low Setting • • •

Auto Power Off (APO)

• • • • • • • •

Temperature Accuracy (°C)

±0.8°C 0.1°C±0.1% to

2°C±0.05% to

±0.7°C±2°C or

±2%±1.5°C to

±3°C ±1.5°C to

±2°C

±2°C to±3°C or

±2%

Range ºC -50 -20 0 100 200 300 900 1000 1100 1200 1300 1400

TP01

TP02A

TP03

TP04

TP04L

Temperature Probes (Type K) - Selection Guide

TP04 Surface contact probe

TP04L Surface contact probe

TP02A General purpose liquid probe

TP01 Bead probe

* Refer to Instruments for full technical data

Page 74: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

79

1.0Environmental Testers and ThermometersInstruments

Weight 220g

Standard Accessories Carry Pouch

Certificates Certificate of Conformance

Model Specification

T325• Sound Level Tester• Type 2 sound level meter• Wide range• Sampling rate 2 seconds

• Bargraph• Min/Max hold• Frequency weighting A/C• Over range indications

T3004• Humidity/Temperature Meter• Data hold• Min/Max• REL function• Auto power off

Display 31/2 Digit LCD Display

Ranges 20, 200, 2000, 20000, 200000 Lux

Resolution 0.01 Lux

Overange OL display

Sampling Time 2.5 times/second

Sensor Material Silicon Photodiode

Accuracy ±3% rdg + 10dgts

Operating Temperature 0 to 50ºC

Operating Humidity < 70% RH

Technical Overview

Power Source 1 x 9V Battery

Standard Accessories Screw Driver, Instruction Manual, Carry Case, Wind Shield

Certificates Certificate of Conformance

Model Specification

Technical Overview

Display 3.5 Digit with Bar Graph

Function Fast (125mS)Slow (1000mS)

Measurement Ranges 30dB to 130dB

Level ranges Low 30dB to 80dB, Med 50dB to 100dB, Hi 80dB to 130dB

Display Update 2sec

Microphone 1/4inch (ECM)

Accuracy ±1.5dB @ 94dB of 1kHz

GENERAL

Output Impedance Approx 100Ω

Operation Humidity 90% RH

Operation Temperature 0˚ to 40˚C

Dimensions (mm) 240 (L) x 54 (W) x 34 (H)

Model Specification

Altitude Up to 2000meters

Temperature -20ºC to 60ºC

Humidity 0% RH ~ 100% RH

Resolution Temperature 0.1ºC / 0.1ºF

Resolution Humidity 0.1% RH

Response Time Humidity 180sec

Response Time Temperature 10sec

Operation Temperature 0ºC to 40ºC

Operation Humidity <80% RH

Sampling Rate 2.5 times per second

Calibration Internal calibration

RH Accuracy ±3% RH

Temp Accuracy ºC ±0.8ºC

Technical Overview

LIFETIME WARRANTY

T630• Digital Luxmeter• 0-200 000 Lux• Data hold• Max hold• Backlit

Page 75: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0 Environmental Testers and ThermometersInstruments

80

Power Source 1 x 9V Battery

Model Specification

Technical Overview

Measurement Range Resolution

m/s 0.4 – 30.0 0.1

km/h 1.4 – 108.0 0.1

Knots 0.8 – 58.3 0.1

Display 18mm LCD, 31/2 dgts

Accuracy ±(2% + 1 Digit) ≤ 25 m/s

Operating Temperature 0°C to 50°C

Dimensions Sensor Head: Round 72mm Dia.

Operating Humidity Max 90% RH, (0°C to 35°C)

Weight 160g

Model Specification

Technical Overview

AIR VELOCITY

Metres Per Second (m/s) 0.4 to 30.0 m/s

Kilometers Per Hour (Km/h) 1.4 to 108.0 km/h

Knots 0.8 to 58.3 Knots

Temperature -100 to 1300°C

Light Intensity 0.2, 200, 1800, 20000 Lux

Humidity 10 to 95%Rh

Metres Per Second (m/s) 0.1 m/s

Kilometers Per Hour (Km/h) 0.1 km/h

Knots 0.1 Knots

Temperature Accuracy 0.1°C/0.1°CF

LIGHT INTENSITY

0, 2, 200 Lux 1 Lux

1800 to 20.000 Lux 10 Lux

HUMIDITY

10 to 95%Rh 0.1%RH

Operating Temperature 0 to 50 °C

Operation Humidity 80%RH Max

Feature Parameter Accuracy

Temperature Range-200°C to 1372°C

-200°C to 1372°C, ±0.1% + 2°C -60°C to 1372°C, 0.1% + 1°C The accuracy specification does not include the probe accuracy.

Resolution 0.1°C/1°C

Technical Overview

Power Source 4 x 1.5V AAA Batteries

Standard Accessories Bead Probe

Model Specification

T4201• Anemometer• Low friction • Ball bearing design• Data hold• 4 Different speed units

T8000• Anemometer/Hygro/Lux/Temp• Display LCD• Auto power off

T500K• Professional Thermometer (Single Input)• K-type Thermocouple• 0.1 °C resolution• Hold function• Max hold• Backlit• Relative zero button

Page 76: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0ThermometersInstruments

81

Feature Parameter Accuracy

Temperature RangeType K: -200°C to1370°CType J: -200°C to 1050°C

-50°C to 1370°C, ± 0.05%, + 0.7°C-200°C to -50°C, 0.05% + 0.3°CThe accuracy specification does not include the probe accuracy.

Resolution 0.1°C/0.2°CF

Technical Overview

Power Source 4 x 1.5V AAA Batteries

Standard Accessories 2 x Bead Probe

Model Specification

Feature Parameter Accuracy

Temperature Range-50°C to 700°C / -58°CF to 1292°CF

0°C~700°C ±1.5°C-50°C to 0°C ±3°C

Resolution 0.1°C / 0.1°CF

Response Time 0.5 Second

Spectral Response 8 to 14µm Nominal

Emissivity Adj. 0.1 to 1

Relative Humidity 10~95%

Technical Overview

Feature Parameter Accuracy

Temperature Range -33°C to 500°C ±2% or 2°C

Resolution -9.99°C to 199.9°C 0.1°C

Response Time 1.0 Second

Wavelength 8 to 14µm

Technical Overview

Power Source 1 x 9V Battery

Standard Accessories 2 x Bead Probe

Model Specification

Power Source 1 x 1.5 AA Battery

Certification CE, RoHS

Model Specification

NOTE: Emissivity - is how infrared is emitted off a particular surface e.g. black is 1 and a very shiny surface like chrome, glass is around 0.3

T502KJ• Professional Thermometer (Dual Input)• K-type and J-type Thermocouple• Data hold • Programmable• Temp1/Temp2 dual display• High/low limit mode• Relative mode• Backlit

TIR9PEN• 9:1 Infrared• Hold Max - Min display• Circular laser• Compact size

T306• Non-contact Thermometer• Laser pointer• Emissivity adjustable• Distance and spot D:S (Field of view) 12:1• Max/Min/Average• High/Low temperature alarm setting

Page 77: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

82

1.0 ThermometersInstruments

Feature Parameter Accuracy

Temperature Range -30°C to 650°C ≥-10°C to < 0°C ±2°C, ≥-0°C: ±1.5%

Resolution 0.1°C

Response Time < 300mS

Spectral Response 8 to 14 µm Nominal

Emissivity Adj. 0.1 to 1

Co-efficient ±0.1°C

Technical Overview

Power Source 3 x AA Batteries

Model Specification

Feature Parameter Accuracy

Temperature Range50°C to1000°C / 58°CF to 1832°CF

±3°C (±5°CF)from -50°C to -20°C±2°C (±3°CF)from -20°C to -100°C±2% from 100 to 1000ºC

Resolution 0.1°C / 0.1°CF

Response Time 0.5 Second

Repeatability ±1ºC or ±2ºF

Emissivity Adj. 0.1 to 1.0

Operating Temperature 0°C to 50°C 10-90% RH

Technical Overview

Power Source 1 x 9V Battery

Model Specification

NOTE: Emissivity - is how infrared is emitted off a particular surface e.g. black is 1 and a very shiny surface like chrome, glass is around 0.3

T151• 4-in-1 Non-contact IR Thermometer • UV refrigerant leak detector• Distance and spot size indicator • Coaxial laser in circle with scale indication of distance

and measured temperature area• D:S (Field of view) 15:1• High and low alarms for measurements outside the limit

T685• High Temperature / Non-Contact

Thermometer• Laser pointer • Dual display

• Emissivity adjustable• 10 Point memory• Distance and spot

D:S (Field of View) 30:1

Page 78: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

1.0Thermal Images - Selection GuideInstruments

83

FEATURE THT45 TG301 THT60 TPK160

PAGE 84 84 85 85

CHARACTERISTICS OF IR IMAGE

IR Sensor Resolution (Pixels) 80 x 80 128 x 128 160 x 120 160 x 120

Temperature Range -20°C to 350°C -30°C to 650°C -20°C to 400°C -20°C to 350°C

Thermal Image Sensitivity < 0.1°C at 30°C 150mK (0.1°C ) ≤ 0.8°C at 30°C 0.8°C at 30°C

Spectrum Range 8 to 14µm 8 to 14µm 8 to 14µm

Type of IR Sensor UFPAIR-EXTM

(Integrated IR Array with CMOS Sensor)

UFPA

Frequency 50Hz 8Hz 50Hz

CHARACTERISTICS OF IR AND INTEGRATED OPTICS

Field of view 17° x 17° 33° x 33° 29.8° x 22.6° 24° x 32°

Focal length of standard lens 9mm 7.5mm Fixed

Interchangeable Optics •

FUNCTIONS

Laser • Circular •

Colour Palettes 4 Standard 3 Standard8 Standard,

10 Custom Colours6 Standard

Saved Image Format JPEG, MPEG4 Bitmap JPEG, MPEG4 JPG

Touch Screen • •

IP Rating IP50 IP50 IP65 IP54

Shock/Vibrations 25G/2G 50G/2.5G 25G/2G 25G/2G

Hot/Cold Spot Auto Auto

Page 79: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

84

1.0 Thermal ImagersInstruments

Display 1.77” Colour TFT with 128 (H) x 160 (V) pixels

Temperature Range -30°C to 650°C

Accuracy (Calibration geometry with ambient temperature 23°C ±2°C)

≥0°C: ±1.5°C or ±1.5°C of reading, whichever is greater

Response Time (95%) <125ms (95% reading) (8Hz)

Spectral Response 8 to 14µm

Emissivity 0.10 to 1.00

Temperature Coefficient ±0.1°C/°C or ±0.1%

Measurement Resolution 0.1°C

Repeatability (% of reading) ±8% of reading or ±1.0°C, whichever is greater

Thermal Imaging detectorIR-EXTM Technology (Integrated IR Array Sensor with CMOS Sensor)

IR Resolution 16.384 pixels (128 x 128 pixels)

Field of View (H x W) 33° x 33°

Thermal Imaging Sensitivity 150mK

Colour Palettes 3 (Grey Scale, Hot Iron and Rainbow)

Save Image Format Bitmap (BMP) Image with Temperature and Emmissivity

Battery Life 12 hours with laser and backlight on

Technical Overview

TG301• 128 x 128 Pixels• Thermal IR camera• UV refrigerant detection• 30:1 distane to spot ratio• Bright flashlight• Circular laser• 1.2m Drop proof

http://www.hellermanntyton.co.za/downloads.html

Application video

Technical Overview

Temperature Range -20°C to 350°C

Thermal Sensitivity <0.1°C @ 30°C

Spectral Range 8 to 14µm

Image Frequency 50Hz

Digital Zoom 1x to 32x

IR Resolution 80 x 80 pixels

Colour Palettes 4 Standard

Integrated Photo Camera 1.3MP

Thermal Imaging Sensitivity 150mK

Thermal imaging Detector IR UFPA

Field Of View 17° x 17°

THT45• 80 x 80 Pixels• Thermal IR camera• PiP function• Automatic detection of hot and cold spots• Built-in laser pointer and illuminator• 3 Cursors: central, Min, Max• Data saved to JPEG and MPEG4

Power Source Lithium-Ion Rechargeable Battery, Battery Charger

Standard AccessoriesFocal lens 9mm,universal plugs, Micro SD card 8GB, USB cable, Video cable, Earphone set, Carry bag, Wrist strap, THTLink Windows software, Quick reference guide, User manual on CD-ROM

Certifiation ISO9000

Model Specification

Power Source 3 x AA IEC LR06 Batteries

Model Specification

Page 80: INSTRUMENTS EARTH RESISTANCE  · PDF fileTLB Page No. 31 53 53 47 46 45 23 27 14 22 16 18 44 42 42 44 Continuity of bonding • • • • • • • ... Auto Power Off (APO)

THT60• 160 x 120 Pixels• Thermal infrared camera • Touch screen 3.5” TFT• Micro-SD card and USB interface to PC• 8 Standard + 10 custom colour palettes • Built in laser pointer and illuminator• PiP function• PAL/NTSC video out

1.0Thermal ImagersInstruments

85

Technical Overview

Field 0f View 24º x 32º

Spatial Resolution 3.05mrad

Thermal Sensitivity ≤ 0.08°C at 30°C

Detector Resolution 160 x 120° pixels

Temperature Range -20°C to 350°C

Focus Fixed

Image Mode IR , CCD

Visible Pixels High Definition CCD, 8 Mega Pixel

Colour Palettes 6 Standards (Iron INV, Rainbow, Feather, Grey and Grey INV))

Display 5.5” HD Capacitive touch screen LCD

File Format JPG

Measurement Functions4 moveable spots , Auto hot/cold spot identification, Isothermal analysis, circle analysis, rectangular analysis, line profile

Measurement Accuracy ±2ºC or ±2% of reading

IP Rating IP54

Shock/Vibrations 25G/2G

APPS Reporter Software Installed as Standard

TPK160• 160 x 120 Pixels• Thermal imager • Integrates tablet and thermal camera technology• Communicate in real time, live image and video transmission• WiFi/Bluetooth• GPS• Built in memory• 8MP CCD digital camera

Technical Overview

Temperature Range -20°C to 400°C

Thermal Sensitivity <0.08°C @ 30°C

Visual Range (FOV) 29.8° x 22.6° (lens 7.5mm)

Spectral Range 8 to 14µm

IR Resolution 160 x 120 pixels

Colour Palettes 8 Standard, 10 Custom Colours

Therman Image Sensitivity 80mK at 30°, 50Hz

Digital Zoom 1x to 20x

Save File Format JPEG, MPEG4

Integrated Photo Camera 60 x 480 pixels

Image Frequency 50Hz

Thermal Image Detector IR UFPA

Power Source 2 x 7.4V Lithium-Ion Rechargeable Batteries

Standard Accessories

7.5mm lens and protection cover, AC/DC adapter + universal plugs, Charger base, 4GB micro SD card and card reader, USB cable for PC connection, RCA video output cable, Rubber support for LCD hood, Rubber support for tripod, Earphone set, CD-ROM with THTLink software, User manual, Hard carry case

Optional Lenses RL1160-11mm, RL2260-22mm and RL3360-33mm

Certifiation ISO9000

Model Specification

Power Source Battery charger

Standard AccessoriesAC adaptor, USB cable, Headset, Wrist Strap, Software App (Installed on the unit), Hard Carrying Case, Operational Manual /Calibration Report

Model Specification