23
1 © 2014 IBM Corporation Installing VIOS … as easy as H.M.C. Jyoti Dodhia [email protected] 2 © 2013 IBM Corporation Agenda What is Virtual I/O Server? Why use it? Current method of installation New easier install via HMC GUI Useful resources What else is new?

Installing VIOS as Easy as HMC 12Feb2014

Embed Size (px)

DESCRIPTION

install VIOS

Citation preview

Page 1: Installing VIOS as Easy as HMC 12Feb2014

1

© 2014 IBM Corporation

Installing VIOS …

as easy as

H.M.C.

Jyoti [email protected]

2 © 2013 IBM Corporation

Agenda

• What is Virtual I/O Server?

• Why use it?

• Current method of installation

• New easier install via HMC GUI

• Useful resources

• What else is new?

Page 2: Installing VIOS as Easy as HMC 12Feb2014

2

3 © 2013 IBM Corporation

Virtual I/O Server – What?

• What is VIOS?

– Appliance - runs in a partition on a POWER6/7 server or blade

– Provides virtual resources to AIX, Linux, and IBM i (i7.1/i6.1) client partitions

– Facilitates sharing of physical I/O resources between partitions

– Core function is virtual I/O: disks, tape, optical, Ethernet

– VIOS packaged in PowerVM

– Advanced functions (Suspend/Resume, LPM, AMS, NPIV, etc)

– Two Virtual I/O Server partitions recommended to provide redundancy

– Partitions can have a mix of physical and virtual resources• Except blades/PureFlex, and certain functions e.g. LPM

4 © 2013 IBM Corporation

Virtual I/O Server – Why?

• Why use VIOS?

– Benefits of virtualisationIncreased utilisation

+ Improved service

+ Improved flexibility

=Reduced costs (hardware, floor space, energy, licensing)

– Faster response to changing business need – flexible infrastructure

– Foundation for future

Page 3: Installing VIOS as Easy as HMC 12Feb2014

3

5 © 2013 IBM Corporation

To VIOS or not to VIOS…• It depends!

• VIOS not usually the best match with IBM i when– Using only internal disks

– Only running a single partition

• VIOS is often a good match with IBM i when– There are many partitions

– Multiple operating system environments e.g. IBM i and AIX / Linux

– Creating/deleting partitions often e.g. for testing

– Requirement to attach to certain external storage (wider range supported via VIOS than direct attach)

• If all partitions to run IBM i only – Consider strategy, advanced functionality requirements, etc

– Is VIOS still best option?

– Is IBM i hosting IBM i sufficient?

• There are always exceptions to above

6 © 2013 IBM Corporation

External Storage

• Wider range of external storage supported with VIOS than with native IBM i attach

• What is supported?– IBM i POWER External Storage Support Matrix Summary

• http://www-03.ibm.com/support/techdocs/atsmastr.nsf/WebIndex/PRS4563

Page 4: Installing VIOS as Easy as HMC 12Feb2014

4

7 © 2013 IBM Corporation

Installing VIOS

• Current install method

– A bit alien if you don’t have AIX experience ...

8 © 2013 IBM Corporation

Install via SMS

• Create a partition for VIOS

• Activate the partition

• Select SMS for Boot mode

Page 5: Installing VIOS as Easy as HMC 12Feb2014

5

9 © 2013 IBM Corporation

And then…

• Press 0 to select console

10 © 2013 IBM Corporation

Next…

• Type 1 for SMS Menu

Page 6: Installing VIOS as Easy as HMC 12Feb2014

6

11 © 2013 IBM Corporation

And so on…

And so on…..

12 © 2013 IBM Corporation

Easier Install via HMC GUI

• HMC enhancement

– V7R7.7.0 SP1• Readme - http://www-

933.ibm.com/support/fixcentral/firmware/readme?fixid=MH01343#enhance

• “Add a GUI enhancement for the installation of VIOS, allowing theuser to install the Virtual I/O Server and managing Virtual I/O Server images using a GUI interface.”

– SP2 recommended• See AIXpert blog entry:• https://www.ibm.com/developerworks/community/blogs/aixpert/entry

/upgrading_to_hmc_v7r770_upgrade_to_service_pack_2_immediately?lang=en

– InfoCenter• http://pic.dhe.ibm.com/infocenter/powersys/v3r1m5/topic/p7hb1/iphb

1_vios_configuring_installhmc_dvd.htm

Page 7: Installing VIOS as Easy as HMC 12Feb2014

7

13 © 2013 IBM Corporation

Let’s begin with HMC

14 © 2013 IBM Corporation

Create partition profile

Page 8: Installing VIOS as Easy as HMC 12Feb2014

8

15 © 2013 IBM Corporation

Activate the VIOS partition

16 © 2013 IBM Corporation

Activating the VIOS partition

Notice that the ‘Open a terminal window’checkbox is greyed out

Page 9: Installing VIOS as Easy as HMC 12Feb2014

9

17 © 2013 IBM Corporation

Installing from Local Repository

NIM Server IP Address is the ipaddress of the HMC.

Here the image VIOS_V2.2.2 has been previously imported

Assumes you will boot over the network as the install image is on HMC – need to ensure that networking is setup correctly

18 © 2013 IBM Corporation

Import install image from HMC’s DVD or remote NFS or SFTP server

If you click on Import, you have following options :

HMC’s DVD drive

Remote NFS server

Remote SFTP server

Page 10: Installing VIOS as Easy as HMC 12Feb2014

10

19 © 2013 IBM Corporation

Or via HMC Management task…

20 © 2013 IBM Corporation

Local Repository example

If you desire to change adapter setting, click Advanced first (when you get back to this screen, the values seems to be blanked out again, and you have to re-fill!)

If you desire to change adapter setting, click Advanced first (when you get back to this screen, the values seems to be blanked out again, and you have to re-fill!)

If you desire to change adapter setting, click Advanced first (when you get back to this screen, the values seems to be blanked out again, and you have to re-fill!)

If you desire to change adapter setting, click Advanced first (when you get back to this screen, the values seems to be blanked out again, and you have to re-fill!)

If you desire to change adapter setting, click Advanced first (when you get back to this screen, the values seems to be blanked out again, and you have to re-fill!)

If you desire to change adapter setting, click Advanced first (when you get back to this screen, the values seems to be blanked out again, and you have to re-fill!)

Page 11: Installing VIOS as Easy as HMC 12Feb2014

11

21 © 2013 IBM Corporation

VIOS ip settings

Enter the ip information for the VIOS server – this will be used to configure networking on the VIOS server as part of the install… and click OK

22 © 2013 IBM Corporation

Install process begins…

Page 12: Installing VIOS as Easy as HMC 12Feb2014

12

23 © 2013 IBM Corporation

And progresses…

24 © 2013 IBM Corporation

The screen auto-refreshes!

Hint:

For better scrollable view - click on the ‘bookmark’ star – this bookmarks the page. Open browser and go to that recently bookmarked page

OR

ssh into the HMC and check /var/log/nimol.log

Page 13: Installing VIOS as Easy as HMC 12Feb2014

13

25 © 2013 IBM Corporation

Easy to scroll and manually refresh

26 © 2013 IBM Corporation

Usually…

• Auto-selects disk to install VIOS to

– hdisk0 usually

– proceeds without user interaction

• In my test � a problem with hdisk0

– So then you need to open a terminal window and follow the prompts to select a disk

Page 14: Installing VIOS as Easy as HMC 12Feb2014

14

27 © 2013 IBM Corporation

As hdisk0 was not available…

Select the disk to install to…

28 © 2013 IBM Corporation

Install progresses…

Page 15: Installing VIOS as Easy as HMC 12Feb2014

15

29 © 2013 IBM Corporation

And completes

Login prompt

30 © 2013 IBM Corporation

Installing from DVD

Can also install from the HMC’s DVD drive

Page 16: Installing VIOS as Easy as HMC 12Feb2014

16

31 © 2013 IBM Corporation

Installing from DVD

32 © 2013 IBM Corporation

Insert next DVD…

Page 17: Installing VIOS as Easy as HMC 12Feb2014

17

33 © 2013 IBM Corporation

Installing from DVD

Install continues as before

34 © 2013 IBM Corporation

And completes

Page 18: Installing VIOS as Easy as HMC 12Feb2014

18

35 © 2013 IBM Corporation

Resources• HMC V7R7.7.0 SP1

– Readme:– http://www-933.ibm.com/support/fixcentral/firmware/readme?fixid=MH01343#enhance

• SP2 recommended– See AIXpert blog entry:– https://www.ibm.com/developerworks/community/blogs/aixpert/entry/upgrading_to_hmc_v7r770

_upgrade_to_service_pack_2_immediately?lang=en

• InfoCenter– http://pic.dhe.ibm.com/infocenter/powersys/v3r1m5/topic/p7hb1/iphb1_vios_configuring_installh

mc_dvd.htm

• AIXchange– VIOS Installation via GUI, Rob McNelly– http://ibmsystemsmag.blogs.com/aixchange/2013/05/vios-installation-via-gui.html

• PowerITPro– How to install VIO Server from the HMC GUI, Glenn Robinson– http://poweritpro.com/blog/how-install-vio-server-hmc-

gui?elq=e8d2069ad6a04951ac5fc14f4a1247c5

© 2012 IBM Corporation

Power Systems Technical Webinar Series

Sessions:#1: Exploiting Virtualisation on IBM Power Systems with PowerVM#2: VIOS - how to get going #3: Controlling processor resources in virtualised partitions#4: Deeper dive into Active Memory Sharing#5: Virtualisation Best Practices#6: Deeper dive into Shared Storage Pools and Thin Provisioning #7: Virtualisation and the world of 10Gbit Ethernet#8: Deeper dive into Active Memory Expansion#9: VIOS maintenance#10: Active Memory Deduplication#11: IBM i Suspend/Resume#12: Dual VIOS Upgrade walk-through#13: Shared Storage Pools ... from Experience#14: IBM i Live Partition Mobility#15: Capture and Deploy partitions#16: Virtual Partition Manager for IBM i

#17&18: Updating Power Systems, I/O and HMC#19&20: Power7 Affinity and Performance#21: Power Advisors (VIOS, LPAR and Java)#22: PowerSC – What/Why/How#23: Dynamic Platform Optimizer (DPO)#24: Removable Disk Cartridge (RDX) on Removable Mass Storage (RMS)#25: Electronic Service Agent#26: Active and Dynamic Systems Optimizer (ASO/DSO)#27: Shared Storage Pools Phase 3#28: Whole POWER Machine Monitoring#29: Monitoring POWER/AIX/VIO with IBM Tivoli Monitoring#30: Tricks of the Power Masters#31: External Storage and IBM i – sizing/modelling#32: Power Systems Configuration Best Practices#33: Shared Storage Pools Phase4#34: PowerVPPlus more planned…

36@JyotiDodhia

A series of technical webinars on Power Systems (including virtualisation):InformalUsually about an hour eachMany include demos

Aimed at:Technical audience - operators, systems administrators and technical specialistsThose using / planning to use IBM's Power based systemsCustomers / Business Partners / IBMersUK & Ireland audience initially, but spread to other countries

More info, replays, and registration at:http://tinyurl.com/PowerSystemsTechnicalWebinarsor send an email to [email protected]

Page 19: Installing VIOS as Easy as HMC 12Feb2014

19

© 2012 IBM Corporation

Power Systems Technical hands-on sessions

A series of technical hands-on sessions on Power Systems (including virtualisation):Informal one-dayChance to try out and see for yourselfVarious topics

Aimed at:Technical audience - operators, systems administrators and technical specialistsThose using / planning to use IBM's Power based systemsIBM’s Customers in UK & Ireland

Sessions:

VIOS for You and i – Jan and Feb � full!

More to follow…

Register your interest:

http://tinyurl.com/IBMPowerHandsOn or send email to [email protected]

38 © 2013 IBM Corporation

What else is new?

Page 20: Installing VIOS as Easy as HMC 12Feb2014

20

39 © 2013 IBM Corporation

PowerVC 1.2 - Virtualization Center

• VM capture & deploy tool and more

• Based on OpenStack

• GA - 6th December 2013

• PowerVC Initial Thoughts– https://www.youtube.com/watch?v=DngP6NH5vLA

• PowerVC 1.1 Hands-On Video (9 min)– https://www.youtube.com/watch?v=Ug-OobzmSEQ

• Virtual Machines it will control– Linux on Power RHEL and SLES– AIX 6 & AIX 7– Statement of direction for IBM i

40 © 2013 IBM Corporation

Key functions

Life cycle of POWER virtual machines

• Register resources – HMC, CEC, storage, VIOS, …– Stateless - gathers information live

• Capture VM OS image

• Deploy images to a VM based on templates

• Start / Stop VM

• Resize � DLPAR

• Add new disks

• Migrate � LPM

• Monitor and ….

Page 21: Installing VIOS as Easy as HMC 12Feb2014

21

41 © 2013 IBM Corporation

https://www.ibm.com/developerworks/servicemanagement/cvm/pvc/index.html

42 © 2013 IBM Corporation

Page 22: Installing VIOS as Easy as HMC 12Feb2014

22

43 © 2013 IBM Corporation

Pre-Requisites

• PowerVC runs on– Power Server running Red Hat RHEL 6.4– x86 running Red Hat RHEL 6.4– You are responsible for sourcing, licensing and S/W maintenance

of RHEL

• Virtual Machines it will control– Linux on Power RHEL and SLES– AIX 6 & AIX 7– Statement of direction for IBM i

• Hardware– POWER7 or POWER7+– PowerVC Standard Edition also covers POWER6/6+ – Power Server or PureFlex Foundation (build to order) node

= which is not FSM controlled i.e. using IVM or HMC

44 © 2013 IBM Corporation

Pricing

Pricing Stand Alone

– PowerVC Express Edition is $60 per managed core forsmall tier machines controlled by IVM

– PowerVC Standard Edition is $80 / $120 /$160 per managed core for small/medium/large machines controlled by HMC

PowerVC will be included in– SWMA for SmartCloud Entry Bundle in Power (5765-SB3)– SWMA for AIX Enterprise Edition– SWMA for System Director VMControl– SWMA for System Director Standard Edition or Enterprise

Edition

SWMA = Software MaintenanceThese are List prices are US Dollars on 8th Oct 2013.They may be different in other countries or not available.

Please ask your IBM Representative for a quote in your country.

Page 23: Installing VIOS as Easy as HMC 12Feb2014

23

45 © 2013 IBM Corporation

This document was developed for IBM offerings in the United States as of the date of publication. IBM may not make these offerings available in other countries, and the information is subject to change without notice. Consult your local IBM business contact for information on the IBM offerings available in your area.

Information in this document concerning non-IBM products was obtained from the suppliers of these products or other public sources. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products.

IBM may have patents or pending patent applications covering subject matter in this document. The furnishing of this document does not give you any license to these patents. Send license inquires, in writing, to IBM Director of Licensing, IBM Corporation, New Castle Drive, Armonk, NY 10504-1785 USA.

All statements regarding IBM future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only.

The information contained in this document has not been submitted to any formal IBM test and is provided "AS IS" with no warranties or guarantees either expressed or implied.

All examples cited or described in this document are presented as illustrations of the manner in which some IBM products can be used and the results that may be achieved. Actual environmental costs and performance characteristics will vary depending on individual client configurations and conditions.

IBM Global Financing offerings are provided through IBM Credit Corporation in the United States and other IBM subsidiaries and divisions worldwide to qualified commercial and government clients. Rates are based on a client's credit rating, financing terms, offering type, equipment type and options, and may vary by country. Other restrictions may apply. Rates and offerings are subject to change, extension or withdrawal without notice.

IBM is not responsible for printing errors in this document that result in pricing or information inaccuracies.

All prices shown are IBM's United States suggested list prices and are subject to change without notice; reseller prices may vary.

IBM hardware products are manufactured from new parts, or new and serviceable used parts. Regardless, our warranty terms apply.

Any performance data contained in this document was determined in a controlled environment. Actual results may vary significantly and are dependent on many factors including system hardware configuration and software design and configuration. Some measurements quoted in this document may have been made on development-level systems. There is no guarantee these measurements will be the same on generally-available systems. Some measurements quoted in this document may have been estimated through extrapolation. Users of this document should verify the applicable data for their specific environment.

Revised September 26, 2006

Special notices

46 © 2013 IBM Corporation

IBM, the IBM logo, ibm.com AIX, AIX (logo), AIX 6 (logo), AS/400, Active Memory, BladeCenter, Blue Gene, CacheFlow, ClusterProven, DB2, ESCON, i5/OS, i5/OS (logo), IBM Business Partner (logo), IntelliStation, LoadLeveler, Lotus, Lotus Notes, Notes, Operating System/400, OS/400, PartnerLink, PartnerWorld, PowerPC, pSeries, Rational, RISC System/6000, RS/6000, THINK, Tivoli, Tivoli (logo), Tivoli Management Environment, WebSphere, xSeries, z/OS, zSeries, AIX 5L, Chiphopper, Chipkill, Cloudscape, DB2 Universal Database, DS4000, DS6000, DS8000, EnergyScale, Enterprise Workload Manager, General Purpose File System, , GPFS, HACMP, HACMP/6000, HASM, IBM Systems Director Active Energy Manager, iSeries, Micro-Partitioning, POWER, PowerExecutive, PowerVM, PowerVM (logo), PowerHA, Power Architecture, Power Everywhere, Power Family, POWER Hypervisor, Power Systems, Power Systems (logo), Power Systems Software, Power Systems Software (logo), POWER2, POWER3, POWER4, POWER4+, POWER5, POWER5+, POWER6, POWER7, pureScale, System i, System p, System p5, System Storage, System z, Tivoli Enterprise, TME 10, TurboCore, Workload Partitions Manager and X-Architecture are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both. If these and other IBM trademarked terms are marked on their first occurrence in this information with a trademark symbol (®or ™), these symbols indicate U.S. registered or common law trademarks owned by IBM at the time this information was published. Such trademarks may also be registered or common law trademarks in other countries. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml

The Power Architecture and Power.org wordmarks and the Power and Power.org logos and related marks are trademarks and service marks licensed by Power.org.

UNIX is a registered trademark of The Open Group in the United States, other countries or both.

Linux is a registered trademark of Linus Torvalds in the United States, other countries or both.

Microsoft, Windows and the Windows logo are registered trademarks of Microsoft Corporation in the United States, other countries or both.

Intel, Itanium, Pentium are registered trademarks and Xeon is a trademark of Intel Corporation or its subsidiaries in the United States, other countries or both.

AMD Opteron is a trademark of Advanced Micro Devices, Inc.

Java and all Java-based trademarks and logos are trademarks of Sun Microsystems, Inc. in the United States, other countries or both.

TPC-C and TPC-H are trademarks of the Transaction Performance Processing Council (TPPC).

SPECint, SPECfp, SPECjbb, SPECweb, SPECjAppServer, SPEC OMP, SPECviewperf, SPECapc, SPEChpc, SPECjvm, SPECmail, SPECimap and SPECsfs are trademarks of the Standard Performance Evaluation Corp (SPEC).

NetBench is a registered trademark of Ziff Davis Media in the United States, other countries or both.

AltiVec is a trademark of Freescale Semiconductor, Inc.

Cell Broadband Engine is a trademark of Sony Computer Entertainment Inc.

InfiniBand, InfiniBand Trade Association and the InfiniBand design marks are trademarks and/or service marks of the InfiniBand Trade Association. Other company, product and service names may be trademarks or service marks of others.

Revised February 9, 2010

Special notices (cont.)