Click here to load reader

STERILIZING SIMPLY AND WELL - SKAN · PDF file HMC EUROPE - STERILIZING SIMPLY AND WELL - HMC EUROPE HMC EUROPEEUROPE HMC EUROPE - STERILIZING SIMPLY AND WELL - HMC EUROPE 9 The HG

  • View
    7

  • Download
    0

Embed Size (px)

Text of STERILIZING SIMPLY AND WELL - SKAN · PDF file HMC EUROPE - STERILIZING SIMPLY AND WELL - HMC...

  • Sterilization Technology

    Sterilization Equipment

    HMCHMC EUROPEEUROPE

    STERILIZING SIMPLY AND

    WELL

  • 2

    ALWAYS IN TOUCH

    …..because we always

    focus on you!

    Your partner for innovation, reliability, durability and in the field of sterilization.

    HMC EUROPE - STERILIZING SIMPLY AND WELL - HMC EUROPE2

    Karin Gabis Processing

    Markus Schmittker Sales

    YOU

    Joachim Lauktien Director

    Jan Loose Technology

    Our Customer

  • HMCHMCHMCHMCYour partner for innovation, reliability, durability and in the field of sterilization.

    HMC EUROPE - STERILIZING SIMPLY AND WELL - HMC EUROPE

    HMCHMCHMCEUROPEEUROPE

    3

    Safety in all areas

    Microbiology

    Biotechnology

    Material Testing

    Material Research

    Medicine/Pharmaceutics

    Research and Development

    Environment and Food Technology

  • 4

    THE DEVICE SERIES

    HMC EUROPE - STERILIZING SIMPLY AND WELL - HMC EUROPE4

    HG For the highest performance and comfort standards

    HV Ingeniously simple

    HMT Reliability on the workbench

  • HMCHMCHMCHMC

    HMC EUROPE - STERILIZING SIMPLY AND WELL - HMC EUROPE

    HMCHMCHMCEUROPEEUROPE

    5

    hg.hmc-europe.eu Automatic opening lid Innovative sealing system Integrated rapid cooling Highly effective spent steam condenser Extremely compact design - space saving Vacuum

    hv.hmc-europe.eu Casters for portability Innovative, passive sealing system Manual lid lock - one-handed operation Quadruple fail-safe heating system with maximum efficiency Only requirement for the setup location: 230 volt outlet

    hmt.hmc-europe.eu Simple operation Simple feed water replacement Automatic program execution Chamber pressure dependent safety lock Low water interrupt

  • Innovativ

    6

    HG SERIES

    HMC EUROPE - STERILIZING SIMPLY AND WELL - HMC EUROPE6

    Top technology All HMC steam sterilizers are produced in modern manufacturing facilities using state of the art technology and are TÜV certified. All devices meet the EC Pressure Equipment Directive and the current European regulations and bear the CE label.

    Easy of use The low loading height and the smooth surface make for easy loading and unloading. There are no obstructing locks or edges on which the baskets could catch.

    Innovative

    No electronics and no moving parts in the lid, therefore reliable and trouble-free. Maximum service life!

    Twice as safe The locking system is coupled with a pressure and temperature monitoring system. Sensors monitor the lid state. Unintended opening under pressure not possible by design. The opening temperature (important for liquid sterilization) can be preset to between 60-97 °C (temperature dependend lid opening).

    Selection criteria Legal: GLP (IQ, OQ, PQ) Documentation S2 (exhaust air filter) Thermolock Application: Chamber volume Documentation Accessories Structural: Available space Infrastructure Supply/disposal Occupational health Loadmaster/lifting system and safety: Trolley Economics: Operating costs Maintenance costs

  • HMCHMCHMCHMC

    7HMC EUROPE - STERILIZING SIMPLY AND WELL - HMC EUROPE

    HMCHMCHMCEUROPEEUROPE Illuminated display

    The clear, bright membrane display shows all important parameters at a glance and is self-explanatory. Simple menu navigation allows adaptations for customized program. 12 programs are available, divided into 4 groups with 3 sub-groups each.

    The optimum for each load.

    • Sterilization of solids: With fast release of steam • Sterilization of liquids: With variable natural cooling or with rapid cooling for thermolabile materials • Sterilization of liquids: with subsequent reheat cycle • AGAR program: processes AGAR and keeps it ready for use (thermostatic heating) • Timer-controlled program: load in the evening - sterile and ready for removal in the morning down to the minute • Waste sterilization: Mixed load with a low liquid content • Automatic standby operation: Saves energy The timer function lets you start the program with a turn-on delay in order to have it end at a precisely defined time.

  • GREEN OPERATION

    In su

    la ti

    ng

    ja ck

    et

    Grünes Arbeiten

    Exhaust air filtration

    Spent steam condenser

    HMC EUROPE - STERILIZING SIMPLY AND WELL - HMC EUROPEHMC EUROPE - STERILIZING SIMPLY AND WELL - HMC EUROPE8

    Spent steam condenser The innovative spent steam condensation system, highly efficient and matched to the energy and volume, prevents odor and steam pollution. This ensures a pleasant indoor climate in the environment of the device.

    Green operation Top-quality materials are used to manufacture the high-tech chambers with a reduced mass. Result is a long service life and short heating and cooling times. Ideal energy efficiency.

    Save resources

  • HMCHMCHMCHMC

    HMC EUROPE - STERILIZING SIMPLY AND WELL - HMC EUROPE

    HMCHMCHMCHMCHMCHMCEUROPEEUROPE

    HMC EUROPE - STERILIZING SIMPLY AND WELL - HMC EUROPE 9

    The HG series: Sophisticated functionality

    The HG series devices are divided into working capacities of 50/80/113/133 litres and set standards with regard to comfort and safety.

    The user will be pleased by the extremely simple operation using the self-explanatory membrane keyboard with LED program display.

    The locking systems for both series consist of a mo- torized lid and an innovative locking system.

    The lid opens at the push of a button: first it only opens a safe gap in order to relieve the remaining pressure, then automatically and finally all the way. Unintended opening is impossible. The user is protected against escaping steam.

    Starting the program as well as opening and closing of the autoclave chamber are triggered via a single key. The lid is lowered gently and locked automati- cally. The program starts automatically.

    The lock operating principles HG 50/80

    The V-seal gasket is activated by pressure. It is embedded in the edge of the lid, and swivelled up and out of the way upon opening to protect it against damage during loading and unloading.

    HG/HGS/HGD 113/133

    The double V-seal gasket seals equally well against vacuum and pressure. It is embedded flush in the edge of the chamber and therefore protected against damage during loading and unloading.

    The seals for both types can be replaced by the user themselves in just a few minutes.

  • The latest generation Versatile with no compromises

    HGD

    Steam generator

    Jacket heating

    Rapid cooling

    Vent valve

    Demineral- ized water

    Tap-water

    Steam cooling

    Exhaust air

    filtration

    Vacuum _p ump

    HMC EUROPE - STERILIZING SIMPLY AND WELL - HMC EUROPE10

    Vent valveVacuum _p ump

    Devices with steam generator and vacuum pump coupled directly to the chamber • Passive seal against vacuum and pressure • Dynamic multi-directional inflow of steam • Permanently available steam • Segmented jacket heating • No heating elements in the chamber • Extremely short heating times • Preheating program • Pyrolytic self-cleaning program • Powerful vacuum pump • Extremely short batch times

    Effective vacuum Pre and drying vacuum for the sterilization of

    • Fabrics • Hollow parts • Tubes • Bottles • Pipettes • Glass containers • All open-pore materials • Mixed fractions in waste bags • Filters

    Two sizes HGD 113 Chamber volume of 131.7 L Effective useful volume of 113 L

    HGD 133 Chamber volume of 153.4 L Effective useful volume of 133 L

    Documentation Simple via USB or printer (can be integrated)

  • HMC EUROPE - STERILIZING SIMPLY AND WELL - HMC EUROPE

    HGDHGDHGDHGDHGDHGDHGDHGDHGDHGDHGDHMCHMCEUROPEEUROPE

    11

    HGDHGDHGDHGDHGDHGDEUROPEHGDHGDEUROPEHGDHGDEUROPEHGDHGDEUROPEHGDHGDEUROPEHGDEUROPEHGDEUROPEHGDHGDEUROPEHGDEUROPEHGDEUROPEHGDHGDHGDHGDHGDHMCHGDHGDHMCHGDHGDHMCHGDHGDHMCHGDHMCHGDHMCHGDHGDHGDHGD HGD Technical Data HGD 113 HGD 133

    Chamber volume Litres 131,7 153,4

    Useful volume Litres 113 133

    Chamber dimensions Ø x H mm 500 x 576 500 x 680

    Exterior dimensions W x D x H mm 686 x 870 x 930 686 x 870 x 1034

    Required space W x D x H mm 700 x 1150 x 1350 700 x 1150 x 1450

    Weight kg 184 192

    Electrical power kW 6,8 7,1

    Integrated steam generator Yes

    Vacuum Yes

    Allowable operating temperature °C 138°

    Selectable operating temperature °C 105° - 135°

    Warming temperature °C 45° - 60°

    Max. operating pressure bar 2,5

    Automatic start variable, 1 minute to 7 days

    Sterilization time t variable, 1 to 300 minutes

    Power supply V AC 400 V 50/60 Hz 3 phase

    Locking system automatic

    Markings CE, TÜV Bayern e.V./TÜV Rheinland

    Vessel material SUS304 (high-grade stainless steel)

    Documentation Integrated printer/USB (optional)

    Safety systems Electro-mechanical safety lock, safety valve, low-water interrupt, overpressure protection switch, overheating protection switch,

    circuit breaker, fault indicator (visual and audible)

    Item Number 21007 21008

    Fast and safe! The HGD devices are equi