4
- 1 - INSTALLATION INSTRUCTIONS S A V E F O R F U T U R E U S E Product names listed herein are trademarks of AS America, Inc. © AS America, Inc. 2017 7302314-100 Rev. B (6/17) RECOMMENDED TOOLS AND MATERIALS Most of the procedures require the use of common tools and materials, which are available from hardware and plumbing supply stores. It is essential that the tools and materials be on hand before work is begun. Thank you for selecting DXV. To ensure this product is installed properly, please read these instructions carefully before you begin. (Certain installations may require professional help.) Also be sure your installation conforms to local codes. CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE! NOTE: Pictures may not exactly define contour of china and components. ! DXV Modulus Wall Hung Dual Flush Toilet with Seat Model D23040A Series Regular Screwdriver 10' Level Closet Bolts Putty Knife Tape Measure Hacksaw Sealant Adjustable Wrench Flexible Supply Tube 1a ROUGHING-IN DIMENSIONS: for GEBERIT FRAME ALL INSTALLATION PROCEDURES MUST COMPLY IN STRICT ACCORDANCE WITH APPLICABLE LOCAL PLUMBING AND BUILDING CODES. SUPPLY AS REQUIRED 19-3/4" (500 mm) 22" (559 mm) 14-3/16" (361 mm) 5-1/2" (140 mm) 11-13/16" (350 mm) FINISHED RIM HEIGHT (FRM) FRM = X PLUS 76 3" (76 mm) 4" (100 mm) 3-1/2" (90 mm) 26-3/8" (670 mm) 6-3/8" (162 mm) 5-1/2" MIN. (140 mm) 2-13/16" (72 mm) 1/2" NPT 4" MIN. (100 mm) FINISHED FLOOR FINISHED FLOOR STUD FRONT CENTER PIPE 4-1/4" (108 mm) 18-1/2" (470 mm) 13-3/4" (350 mm) 7-1/8" (180 mm) 0" - 7-7/8" (0 - 200 mm) 12"-16" (305-407 mm) 45"-49" (1143-1249 mm) X OPTIONAL SUPPLY FOR WASHLET SEAT

INSTALLATION INSTRUCTIONS - Microsoft · L5R 3M3 Canada Toll Free: 1-800-387-0369 Local: 905-306-1093 Fax: 1-800-395-1498 ... (for carrier repair parts please check carrier installation

Embed Size (px)

Citation preview

- 1 -

INSTALLATION INSTRUCTIONS

SA

VE

F

OR

F

UT

UR

E

US

E

Product names listed herein are trademarks of AS America, Inc.© AS America, Inc. 2017 7302314-100 Rev. B (6/17)

RECOMMENDED TOOLS AND MATERIALSMost of the procedures require the use of common tools and materials, which are available from hardware and plumbing supply stores. It is essential that the tools and materials be on hand before work is begun.

Thank you for selecting DXV. To ensure this product is installed properly, please read these instructions carefully before you begin. (Certain installations may require professional help.) Also be sure your installation conforms to local codes.

CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE!NOTE: Pictures may not exactly define contour of china and components.

!

DXV Modulus™ Wall Hung Dual Flush Toilet with SeatModel D23040A Series

Regular Screwdriver

10'

Level

Closet Bolts

Putty Knife

Tape Measure Hacksaw

SealantAdjustable Wrench

Flexible Supply Tube

1a ROUGHING-IN DIMENSIONS: for GEBERIT FRAME

ALL INSTALLATION PROCEDURES MUST COMPLY IN STRICT ACCORDANCE WITH APPLICABLE LOCAL PLUMBING AND BUILDING CODES.

SUPPLYAS REQUIRED

19-3/4"(500 mm)

22"(559 mm)

14-3/16"(361 mm)

5-1/2"(140 mm)

11-13/16"(350 mm)

FINISHED RIMHEIGHT (FRM)

FRM = X PLUS 76

3" (76 mm)

4"(100 mm)

3-1/2"(90 mm)

26-3/8"(670 mm)

6-3/8"(162 mm)

5-1/2"MIN.

(140 mm)2-13/16"(72 mm)

1/2"NPT

4" MIN.(100 mm)

FINISHEDFLOOR

FINISHEDFLOOR

STUD FRONTCENTER PIPE4-1/4"

(108 mm)

18-1/2"(470 mm)

13-3/4"(350 mm)

7-1/8"(180 mm)

0" - 7-7/8"(0 - 200 mm)

12"-16"(305-407 mm)

45"-49"(1143-1249 mm)

X

OPTIONAL SUPPLYFOR WASHLET SEAT

- 2 -

These 2 brackets must be installed during tank frame installation. The brackets are delivered with the tank frame.

NOTE: If using GROHE carrier, skip steps 2 to 5.

7302314-100 Rev. B (6/17)

2

3 4 5

SUPPLYAS REQ’D

19-11/16"(500 mm)

22"(559 mm)

14-3/16"(361 mm)

5-1/2"(140 mm)

11-13/16"(300 mm)

FINISHED RIMHEIGHT (FRM)

FRM = X PLUS 76

3" (76 mm)4"(100 mm)

5-1/2"MIN.

(140 mm)

1/2"NPT

4" MIN.(102 mm)

FINISHEDFLOOR

FINISHEDFLOOR

STUD FRONTCENTER PIPE4-1/4"

(108 mm)

18-1/2"(470 mm)

13-3/4"(350 mm)

7-1/16"(180 mm)

0" - 7-7/8"(0 - 200 mm)

12"-16"(305-407 mm)

44-1/2"-48-7/16"(1130-1230 mm)

X

1b ROUGHING-IN DIMENSIONS: for GROHE FRAME

- 3 -

BOWL INSTALLATION:

Remove yellow protection plugs and seals from pipes.

Add dimension Y and 1/8" (3 mm). Using that dimension, mark a line on the pipe measuring from the hub side. Cut off the pipe at the line with a pipe cutter.

Place discharge pipe with gasket into waste outlet of bowl. Also place flush pipe with fin gasket into inlet of bowl. Then mark a second line on both pipes.

Insert discharge pipe into the pipe hub in the wall. Place a straight edge flush against the wall and mark a line on the pipe. Fit finned rubber seal onto flush pipe. Repeat same procedure for discharge pipe.

Bevel the sharp edges as shown to assure a smooth insertion into the pipe hubs in the wall.

Add dimension X and 1/8" (3 mm). Using that dimension, mark a line on the pipe measuring from the hub side. Cut off the pipe at the line with a pipe cutter.

7302314-100 Rev. B (6/17)

6d 6e

6 6a

6c6b

X

X

+1/8"+(3 mm)

+1/8"+(3 mm)

Y

Y

- 4 -

In the United States:DXVOne Centennial Avenue Piscataway, New Jersey 08855Attention: Director of Customer Care

For residents of the United States, warranty information may also be obtained by calling the following toll free number: (800) 227-2734www.DXV.com

In Canada:DXV 5900 Avebury Road Mississauga, Ontario L5R 3M3Canada

Toll Free: 1-800-387-0369Local: 905-306-1093Fax: 1-800-395-1498www.DXV.ca

In Mexico:DXV Via Morelos 330Col. Santa Clara Coatitla Ecatepec, Estado de México 55540

Toll Free: 01-800-8391200www.DXV.mx

7302314-100 Rev. B (6/17)

COMPONENT NUMBER DESCRIPTION

D23040A000.415 With seat

5026A.10G.415 Seat

D29000000.000 Geberit In wall carrier

D28030000.415 Geberit square button dual flush plate

D29054026.000 Grohe In wall carrier

D28015000.415 Grohe dual flush plate

(for carrier repair parts please check carrier installation instructions)

Seal gap around bowl with waterproof sealant.

6i6h

Install both seals into the pipes in the wall. Lubricate seals with appropriate rubber seal lubricant.

Remove protective sleeves from threaded mounting rods. Install rods with a protruding length of 1-3/8" (35 mm) from the finished wall. Then install the threaded nuts leaving approximately 3/8" (10 mm) of the threaded rod exposed. Also insure the concave portion of the nut is facing down! Install both pipes into the hubs in the wall.

6f 6g

3/8"(10 mm)

Ensure each of the pre-installed 4 fingered plastic mounts are securely mounted into each mounting hole of the toilet. Place bowl onto female threaded nuts and carefully insert bowl so the threaded female nuts go into the plastic finger housings mounted in the toilet. Once toilet is fully mounted into the female threaded nuts, turn the hex allen rod insert-ed into the plastic housing clockwise to tighten toilet into finished wall.

FemaleThread Nut

Concave

4 Fingered plastic mount

Hex allen rod

Hex allen handle