Return Loss Meter
Fiber Type: Singlemode Multimode
Source Wavelength 1310nm/1550nm (1490nm/1625nm) 850nm or 1300nm
Measurement Range -10dB..-72dB (-80dB FTTX) -10dB..-55dB
Absolute Accuracy +/-1dB, -14..65 +/- 2dB 65..72 +/-1dB -10..-45, +/- 2dB 45..55
Distance Range (Reference Cable to DUT) 2.5m..2400m
Multichannel Source
Source Type: LED Laser
Wavelength ( individual) POF, 850nm, 1300nm 850nm, 1310nm, 1550nm, 1625nm
Dual Wavelength 850nm/1300nm 1310nm/1550nm
Output Power -13dBm (output power depends on fiber size) 0dBm
Stability (1 hour @ Ambient, Overall) +/- 0.02dB, +/- 0.05dB +/- 0.02dB, +/- 0.05dB
Number of Channels Up to 24 individual or dual wavelength sources per instrument
Optical Interface FC, ST, SC (others upon request)
Multichannel Optical Power MeterDetector (various detector areas available) InGaAs (1mm, 3mm, 5mm,10mm) Silicon (3mm)
Measurement Range +3dBm..-80dBm, +27dBm .. -55dBm +3dBm..-60dBm
Wavelength Range 830nm..1700nm 480nm..1080nm
Selectable Wavelength 850/980/1310/1480/1550/1625nm 650/850/980nm
Measurement Resolution (Display) 0.01dBm (absolute) 0.001dB (relative)
Measurement Linearity (Relative Accuracy) +/-0.05dB
Number of Channels 4 to 24 per instrument
Data Acquisition Rate >10 samples/second acquisition rate
OP71
0
Insertion Loss MeasurementThe OP815 offers a highly integrated, single unit solution for efficiently measuring insertion loss on singlemode, mulitmode fiber cable as well as POF. The instrument includes a single dual-precision optical power meter and a single or dual wavelength light source.
Optical Power MeterMeasurement Range +3dBm..-80dBm
Wavelength Range 830nm..1700nm (InGaAs Detector) 480nm ... 1080nm (Silicon Detector)
Selectable Wavelength Standard: 850/980/1300/1310/1480/1550/1625nm 630/650/780/850/980nm
Measurement Resolution (Display) 0.01dBm (absolute) 0.001dB (relative)
Measurement Linearity (Relative Accuracy)*** 0.05dB
Stabilized Source: Laser LED
Source Wavelength 850nm, 1310nm, 1550nm, 1490nm, 1625nm * 850nm, 1300nm or both, 650nm *
Output Power typ. 0 dBm (1mW) typ. -15dBm (into 62.5MM)
Launch * * Singlemode CPR>21dB
Source & Power Channels 1 or 2 each
OP
815 &
OP
815D
Bidirectional Insertion Loss Measurement
Built upon the proven technology of the OP815 and equipped with a highly repeatable cross connect switch, the OP831 is the efficient solution to measure insertion loss on both ends of singlemode or multimode cables in one measurement.
Optical Power Meter
Measurement Repeatability IL +/- 0.075dB (includes 2x2 switch, source stability, power meter linearity)
Measurement Time (Dual wavelength both directions) 3 sec. (For best repeatability)
Multichannel InstrumentsMultichannel Optical Power Meter
The OP710 offers unparalleled data acquisition speed for multichannel optical power measurements. Configurable with a variety of detectors and connector interfaces multiple instruments can be combined for a higher channel count.
Multichannel SourceThe OP750 multichannel source can be configured for a mix of up to 24 individual LED or Laser sources. Depending on the application, individual sources or a switched solution can be configured.
Multifiber/Ribbon TestingO
P831
OP710 Multichannel Optical Power Meter Low Polarization Dependence (LPD) , High Power, and Wide Spectral Response (WSR) models are available.
OP75
0
Instrument SelectionBesides the Turnkey Solution for 12 fiber MTP/MPO connectorized cables and hybrids, OptoTest offers a variety of instruments and options that are engineered to match the measurement applications, be it simplex, duplex, ribbon, or multi-fiber cables terminated with any of the industry available connectors.
Return Loss MeasurementThe Insertion Loss and Return Loss on optical components is measured fast and accurately with the TIA approved “no mandrel” method. Neither matching gel nor mandrel wraps are required for testing of the cable.
OP
930
OPL Application Software
Insertion Loss & Return Loss Measurement
Reflective Event Comparison Method (RECM) per TIA TSB-142.
Fiber Type: Multimode Singlemode
Source Channels 4...12, 24 (or custom)
Insertion Loss Source 850nm, 1300nm Launch Condition TIA compliant
1310nm, 1550nm1490nm, 1625nm
Return Loss Source 850nm, 1310nm 1310nm, 1550nm1490nm, 1625nm
Source Stability +/-0.02dB (0.05dB)
Optical Power Meter Range (for 5mm, 10mm Detector or Integrating Sphere)
+3dBm ... -45dBm
Insertion Loss Accuracy +/- 0.05dB
Return Loss Range -10dB .. -52dB -10dB .. -72dB
Return Loss Accuracy * +/-1dB
Channel Repeatability +/-0.05dB
Measurement Speed typ.1 sec.per channel & wavelength pair
OPL-ProThis cable test utility automates the Insertion Loss, Return Loss measurement process in manufacturing greatly. OPL-Pro operates with all single channel and bidirectional instruments.
Real-time display•Pass/Fail criteria•Serialized Cable Test•Bidirectional Testing•Datafile in Excel format•User configurable setup•Auditing trails•
OPL-Max This application supports multichannel serialized cable testing for Insertion Loss and Return Loss..
Programmable Sequences•Reference Wizard•Checks for Continuity/ •Crossed Fiber
Retest of individual channels•Test Report•Data in Excel format•Measurement Log for audits•
OPL-LOG A customizable application controlling
combinations of Sources, Return Loss
modules, power meters, and third party
instruments, to log data over time.
Timer based data acquisition•Capture IL, RL, temperature and auxiliary •parameters
Data in Excel format•Programmable Sequences•Graphical display of results vs. time•
Singlemode fiber 5mm Detector Integrating Sphere
SM/MM fiber 10mm Detector Integrating Sphere
Bare ribbon fiber (any type)10mm DetectorIntegrating Sphere
Measuring Insertion Loss (IL) and Return Loss (RL) on multiple fibers can be challenging; the connectors may be difficult to clean, high quality reference cables may be hard to get and the measurement step requires fiber management and organizational skills beyond belief.
With the OPSeries Multifiber Test Systems, tailored solutions measure the necessary parameters on Multifiber cables such as MTP/MPO Cables, Fanouts, Multi-termini Connectors, and even Duplex or Simplex Cables.
OP930
OP815
OP831
OP750
OP710
Optical Power Meter : Same performance as the OP815 & OP815D.
Stabilized Source : Same performance as the OP815 & OP815D.
Appropriate Detector SelectionTo measure power levels on ribbon fibers terminated with any of the MT connectors styles, the following large area detector options are supported: * Others upon request ** Can be configured per customer's request including encircles flux per TIA/IEC *** Dynamic Range depends on detector type.
* mm: -10..-45, 5m -10...-65, +/-2dB otherwise
www.optotest.comOptoTest® is a registered trademark of OptoTest Corporation of California.
Copyright © 2006 OptoTest Corporation. All rights reserved. w w w . o p t o t e s t . c o m
F i b e r O p t i c P o w e r M e t e r s
I n s e r t i o n L o s s M e a s u r e m e n t
R e t u r n L o s s M e a s u r e m e n t
B i d i r e c t i o n a l Te s t i n g
Discontinuity AnalyzerOptical Channels 2..24 Channels
Optical Receiver80μm InGaAs DetectorWavelength range: 830nm to 1650nmInput power range: 0dBm to -36dBm
Optical Power Meter Input power range: -3dBm to -40dBmAccuracy: +/-0.05dB
Optical Interface Fixed FC (others upon request)
Discontinuity DetectionEvent duration: >0.4μsec to 1secEvent amplitude: >= 0.5dBSampling interval: 0.4μsec .. 10msecEvent trace: 1000 samples
Trigger Method Each individual channel, timer based or event based
Data Interface USB 1.1, USB 2.0 compatible data rate and interconnect
Mech. Dimension Standard 19" Rack, 2U or 4U (8channels+)
OP11
00
Discontinuity Analyzer
Remote Head Detectors Intergrating Sphere
The OP1100 Discontinuity Analyzer is an off-the-shelf fiber optic test system that automatically captures, displays and logs short optical power interruptions and spikes in accordance with EIA/TIA-FOTP-32A.
This test solution provides a method for testing a broad variety of passive or active fiber optic components for susceptibility to discontinuities (signal dropout, transient output or transmittance fluctuations) during application of an external stimulus, such as temperature, vibration or physical shock.
Stabilized Light Source
Source Type: LED Laser
Wavelengths 650/850/1300 630/850/9801310/1550/1625
Output Power >-17dBm * >-3dBm
Fiber Interface50/12562.5/125
9/125
Connector Type FC, ST, SC (others on request)
Data Interface USB 1 & 2
Power USB, internal LiIon Battery
OP250
Reference CablesInsertion Loss <0.05dB
Return Loss>55dB (PC)
>70dB (APC)>50dB MM
Radius of Curvature 14..25mm8..12mm
Apex offset <30um
Fiber Height +/- 50nm
Fiber Core Position <0.5um
The USB powered fiber optic modules, optical power meters, laser and LED sources, provide a cost-effective means of delivering light and measuring optical power.
This Smart Dual Port Intergrating Sphere benifits quality hybrid cables, bare fiber and ribbon cables.
Remote head detectors allow to position the detector to where Insertion Loss needs to be measured. This is specifically a great conveniance for cable harnesses.
* output power depends on connected fiber type
Fiber Optic Power MeterDetector Types: InGaAs Silicon
Detector Sizes fixed, 1 .. 10mm 0.3, 3mm
Measurement Range * +3dBm.. -80dBm
+3dBm.. -65dBm
Wavelength Range 830nm.. 1700nm
480nm.. 1080nm
Linearity * 0.05dB
Display LED Bar graph (OP510)
Optical InterfaceFixed FC, ST, SC (others on request)
Exchangeable Adapter
Power & Data Interface USB 1 & 2
OP508 /510
* range depends on detector type
HPR
Analyzers Options
USB Powered Modules
Launch Condition Analyzer System / Encircled Flux
Measurements for Encircled FluxThe Launch Condition Analyzer characterizes connectors, fiber components and provides graphs illustrating how light exits the fiber. The analyses ensure conformity to industry standards.
Nearfield Analyzer The Nearfield (NF) describes the optical power density on the surface of a radiating source or the end of a fiber. The nearfield measurement can determine the refractive index profile of multimode fibers and the fiber’s mode filling, launch condition, and Encircled Flux (per TIA).
Farfield AnalyzerThe Farfield (FF) measurement is the optical power density of a source or fiber end on a surface measured at a radial distance. The farfield measurement can determine the numerical aperture of sources and fibers.
Launch Condition AnalyzerFarfield Scan Range +/-0.5NA, 0.01NA resolution
Nearfield Scan Range +/-150μm, 0.2μm resolution
Wavelength Range830nm .. 1700nm (InGaAs)
430nm .. 1080nm (Silicon)
Optical Power Range +20dBm .. -45dBm
Optical Interface Universal 2.5mm, 1.25mm, 1.6mm
Mech Dimension Standard 19" Rack, 3U
Analysis SoftwareFarfield scans Nearfield scans
OP10
21
M u l t i - C h a n n e l Te s t S o l u t i o n s
L a u n c h C o n d i t i o n M e a s u r e m e n t
E n g i n e e r e d M e a s u r e m e n t S o l u t i o n
A p p l i c a t i o n S o f t w a r e
OP1021
OP1100
OptoTest Corp. 4750 Calle Quetzal
Camarillo,CA 93012
m 805.987.1700 f 805.832.6414 www.optotest.com
OptoTest Corp. 4750 Calle Quetzal
Camarillo,CA 93012
m 805.987.1700 f 805.832.6414 www.optotest.com
[email protected] [email protected]
*Singlemode or Multimode
InGaAs: 1mm 2mm, 3mm, 5mm, 10mm
Silicon: 3mm