Americas Headquarters: © 2008 Cisco Systems, Inc. All rights reserved. Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA Input/Output Controller Replacement Instructions Product Numbers: C7200-I/O-FE-MII=, C7200-I/O=, C7200-I/O-FE=, C7200-I/O-2FE/E=, C7200-I/O-GE+E=, UBR7200-I/O=, UBR7200-I/O-FE=, UBR7200-I/O-2FE/E=, CISCO7202=, CISCO7204=, CISCO7206=, CISCO7204VXR=, CISCO7206VXR=, CHAS-UBR7246VXR=, CHAS-UBR7246=, CHAS-UBR7223=, RS7206S=, RS7206VXR-SK=, IO-CONTROLR-BLANK= Document Version History The document version history is in Table 1. Introduction This document explains how to remove and replace the input/output (I/O) controller. This document includes instructions for powering down a router, removing an installed I/O controller, installing a new I/O controller in the router, and verifying the initialization of the installed I/O controller after you power up the router. This document also includes steps for installing and removing a Flash memory card. Table 1 Document Version History Document Version Date Notes OL-4447-02 February, 2008 Removed references to UBR7200-NPE-G2 nonsupport. OL-4447-01 October, 2005 This version adds warning statement numbers and fiber-optic cleaning information.

Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

  • Upload
    others

  • View
    24

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Input/Output Controller Replacement Instructions

Product Numbers: C7200-I/O-FE-MII=, C7200-I/O=, C7200-I/O-FE=, C7200-I/O-2FE/E=, C7200-I/O-GE+E=, UBR7200-I/O=, UBR7200-I/O-FE=, UBR7200-I/O-2FE/E=, CISCO7202=, CISCO7204=, CISCO7206=, CISCO7204VXR=, CISCO7206VXR=, CHAS-UBR7246VXR=, CHAS-UBR7246=, CHAS-UBR7223=, RS7206S=, RS7206VXR-SK=, IO-CONTROLR-BLANK=

Document Version HistoryThe document version history is in Table 1.

IntroductionThis document explains how to remove and replace the input/output (I/O) controller. This document includes instructions for powering down a router, removing an installed I/O controller, installing a new I/O controller in the router, and verifying the initialization of the installed I/O controller after you power up the router. This document also includes steps for installing and removing a Flash memory card.

Table 1 Document Version History

Document Version Date Notes

OL-4447-02 February, 2008 Removed references to UBR7200-NPE-G2 nonsupport.

OL-4447-01 October, 2005 This version adds warning statement numbers and fiber-optic cleaning information.

Americas Headquarters:

© 2008 Cisco Systems, Inc. All rights reserved.

Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA

Page 2: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Contents

ContentsThis document contains the following sections:

• Related Documentation, page 2

• Input/Output Controller Description, page 3

• Installation Prerequisites, page 19

• Removing and Replacing the Input/Output Controller, page 31

• Configuring the I/O Controller Interfaces, page 52

• Using show Commands to Check the Installation, page 57

• Troubleshooting, page 62

• Connection Equipment and Port Signaling, page 64

• Upgrading the Boot Helper (Boot Loader) Image, page 76

• Installing and Removing a Flash Memory Card or Flash Disk, page 78

• Fiber Optic Cleaning Information, page 81

• FCC Class A Compliance, page 81

• Obtaining Documentation and Submitting a Service Request, page 82

• Obtaining Additional Publications and Information, page 82

Related DocumentationFor related documentation, see the following online master indexes for a listing of all documents related to this product:

• Cisco 7200 Series Routers Documentation Roadmap at: http://www.cisco.com/univercd/cc/td/doc/product/core/7200vx/3512.htm

• Regulatory Compliance and Safety Information for the Cisco 7200 Series Routers at:http://www.cisco.com/univercd/cc/td/doc/product/core/7206/3419pnc6.htm

• Cisco 7200 Series Routers Port Adapter Documentation Roadmap at: http://www.cisco.com/univercd/cc/td/doc/product/core/7200vx/3530.htm

• Cisco 7200 Series Routers Troubleshooting Documentation Roadmap at: http://www.cisco.com/univercd/cc/td/doc/product/core/7200vx/3518.htm

• For Cisco IOS configuration documentation including release notes and feature modules, see:http://www.cisco.com/univercd/cc/td/doc/product/software/index.htm

• For hardware and software compatibility information, access the Software Advisor at the following URL: http://www.cisco.com/univercd/cc/td/doc/product/core/7200vx/7200trbl.htm.

• For information about the Cisco uBR7200 series routers, refer to the following publications:

– Cisco uBR7200 Series Universal Broadband Router Hardware Installation Guide at:http://www.cisco.com/univercd/cc/td/doc/product/cable/cab_rout/cr72hig/index.htm

– Cisco uBR7200 Series Configuration Notes at:http://www.cisco.com/univercd/cc/td/doc/product/cable/cab_rout/cfig_nts/index.htm

2Input/Output Controller Replacement Instructions

OL-4447-02

Page 3: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Input/Output Controller Description

• For hardware installation and maintenance information and software configuration information on the Cisco AS5800 Universal Access Server, refer to the following publications:

– Cisco AS5800 Universal Access Server Hardware Installation Guide

– Configuration documents for the Cisco AS5800

• To view Cisco documentation or obtain general information about the documentation, refer to the following sources:.

– “Obtaining Documentation and Submitting a Service Request” section on page 82.

– “Obtaining Additional Publications and Information” section on page 82

– Cisco Information Packet that shipped with your router or switch.

Input/Output Controller DescriptionThe input/output controller shares the system memory functions and the environmental monitoring functions with the network processing engine or network services engine in the Cisco 7200 series routers and Cisco uBR7200 series routers, which include the following:

• Cisco 7200 series routers, consisting of the two-slot Cisco 7202, four-slot Cisco 7204 and Cisco 7204VXR, and six-slot Cisco 7206 and Cisco 7206VXR

Note The Cisco 7206 and Cisco 7206VXR can be used as router shelves in a Cisco AS5800 universal access server. References to the Cisco 7200 series routers in this document include the Cisco 7206 and Cisco 7206VXR as router shelves in a Cisco AS5800 universal access server, unless indicated otherwise.

• Cisco uBR7200 series universal broadband routers, consisting of the six-slot Cisco uBR7246VXR and Cisco uBR7246 (two port adapter slots and four cable modem card slots) and the three-slot Cisco uBR7223 (one port adapter slot and two cable modem card slots)

This document describes five different models of I/O controllers that are distinguished from one another by their Ethernet interface options. Table 2 lists the I/O controllers by product number and describes their differences. See also the “Software and Hardware Requirements” section on page 20.

Table 2 I/O Controller Descriptions1

Product Number Description

Cisco 7202, Cisco 7204, Cisco 7206

Cisco 7200 VXR Routers

Cisco uBR7200 Series2

— C7200-I/O-GE+E — 1 Gigabit Ethernet and 1 Ethernet port; equipped with a GBIC port for 1000 megabits per second (Mbps) operation and an RJ-45 port for 10-Mbps operation. (See Figure 1.)

— C7200-I/O-2FE/E UBR7200-I/O-2FE/E 2 autosensing Ethernet/Fast Ethernet ports; equipped with 2 RJ-45 ports for 10/100 Mbps operation. (See Figure 2.)

C7200-I/O-FE3 C7200-I/O-FE3 UBR7200-I/O-FE 1 Fast Ethernet port; equipped with an MII port and an RJ-45 port for use at 100 Mbps full-duplex or half-duplex operation. Only 1 port can be configured for use at a time. (See Figure 3.)

C7200-I/O C7200-I/O UBR7200-I/O Has no Fast Ethernet port. (See Figure 5.)

3Input/Output Controller Replacement Instructions

OL-4447-02

Page 4: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Input/Output Controller Description

Note Throughout this document the different I/O controller models are referred to by their Cisco 7200 series product numbers; however, the information presented is the same for corresponding I/O controllers used in Cisco uBR7200 series routers, unless otherwise noted.

The I/O controllers consist of the following components and options:

• Ethernet, Fast Ethernet, or Gigabit Ethernet interface options

• Dual channels for local console and auxiliary ports

The console port has full data communications equipment (DCE) functionality, and the auxiliary port has full data terminal equipment (DTE) functionality.

• NVRAM for storing the system configuration and environmental monitoring logs

Note NVRAM uses lithium batteries to maintain its contents when disconnected from power. Some I/O controllers use a static RAM (SRAM) component with an external lithium battery to provide the same functionality as the NVRAM. (See Figure 1 and Figure 2.)

• Two PC card slots that hold Flash Disks or Flash memory cards for storing the default Cisco IOS software image

• Flash memory for storing the boot helper (boot loader) image

• Boot ROM for storing sufficient code for booting the Cisco IOS software

• Two environmental sensors for monitoring the cooling air as it enters and leaves the chassis

C7200-I/O-FE-MII4 — — 1 Fast Ethernet port; equipped with a single MII port. (See Figure 7.)

IO-CONTROLR-BLANK=

Yes — I/O Controller Blank panel for use in the I/O controller slot when no I/O controller is in the router.

1. The C7200-I/O-FE-MII I/O controller has reached its end-of-life and is no longer an orderable product as of April 1998. The C7200-I/O-FE I/O controller has reached its end-of-life and is no longer an orderable product as of December 2000.

2. The Cisco uBR7200 series I/O controllers have the boot helper (boot loader) image used by a Cisco uBR7200 series router loaded on the Flash memory SIMMs. The Cisco 7200 series I/O controllers do not.

3. The product number C7200-I/O-FE does not specify MII because both an MII and an RJ-45 port are included.

4. The I/O controller with the product number C7200-I/O-FE-MII has a single MII Fast Ethernet port only.

Table 2 I/O Controller Descriptions1

Product Number Description

Cisco 7202, Cisco 7204, Cisco 7206

Cisco 7200 VXR Routers

Cisco uBR7200 Series2

4Input/Output Controller Replacement Instructions

OL-4447-02

Page 5: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Input/Output Controller Description

Figure 1 C7200-I/O-GE+E With GBIC Gigabit Ethernet and RJ-45 Ethernet Ports

1 Temperature sensor 8 Captive installation screw

2 Midplane connectors 9 PC Card slots

3 Battery for SRAM 10 GBIC port

4 8-MB Flash memory (soldered) (U13) 11 RJ-45 (Ethernet) port

5 8-MB Flash memory (soldered) (U25) 12 Auxiliary port

6 Temperature sensor 13 Console port

7 SRAM

8452

6

LINKC7200-I/O-GE+E

CLA

SS 1

LED

PRO

DU

CT

P

RO

DU

KT M

IT K

LASSE 1

LED

PRO

DU

IT A

VEC

VOYA

NT D

EL

D

E C

LASSE 1

PRO

DU

CTO

LED

DE C

LASE 1

ETHERNET GIGABIT ETHERNET INPUT/OUTPUT CONTROLLER

CONSOLEAUX

PORTE 0

LINK

SLOT 0PORT

GE ORX TX

EJECT

PCMCIA

SLOT 1

ENABLED

CPU

RESET

IO P

WR

OK

9

8

121110 13

1 3

7

6

54

2

5Input/Output Controller Replacement Instructions

OL-4447-02

Page 6: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Input/Output Controller Description

Figure 2 C7200-I/O-2FE/E With Two RJ-45 Ethernet/Fast Ethernet Ports

Your I/O controller with the MII and RJ-45 Fast Ethernet ports (C7200-I/O-FE or UBR7200-I/O-FE) might look like the first illustration in Figure 3 (with NVRAM), or it might look like the second illustration in Figure 4 (with SRAM replacing the NVRAM). There is no functional difference between these two I/O controllers with the Fast Ethernet port.

1 Temperature sensor 7 SRAM

2 Midplane connectors 8 Captive installation screw

3 Battery for SRAM 9 PC Card slots

4 8-MB Flash memory (soldered) (U13) 10 RJ-45 (Ethernet) ports

5 8-MB Flash memory (soldered) (U25) 11 Auxiliary port

6 Temperature sensor 12 Console port84

525

DUAL FAST ETHERNET INPUT/OUTPUT CONTROLLERC7200-I/O-2FE/E

CONSOLEAUX

100 Mbps

LINK

100 Mbps

FE/E 0

FE/E 1

LINK

SLOT 0

EJECT

PCMCIA

SLOT 1

ENABLED

CPU

RESET

IO P

WR

OK

9

8

11 12

1 3

7

6

54

2

10

6Input/Output Controller Replacement Instructions

OL-4447-02

Page 7: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Input/Output Controller Description

Figure 3 C7200-I/O-FE With MII and RJ-45 Fast Ethernet Ports (with NVRAM)

1 Temperature sensor 8 PC Card slots

2 Midplane connectors 9 Optional Fast Ethernet interface (MII port and RJ-45 port)

3 Flash SIMM (U99) 10 LEDs

4 Boot ROM (U20) 11 CPU reset button

5 NVRAM (U41) 12 Auxiliary port

6 Temperature sensor 13 Console port

7 Captive installation screw84

531

AUX

CONSO

LE

PCMCIA

EJECT

SLOT 0

SLOT

1

FE MII

FAST ETHERNET INPUT/OUTPUT CONTROLLER

RJ45

CPU RESET

MII

EN

RJ45

EN RJ45

LINK

I/O P

WR

OK

ENABLED

8

10

7

111312

1

4

3

56

9

2

7Input/Output Controller Replacement Instructions

OL-4447-02

Page 8: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Input/Output Controller Description

Figure 4 C7200-I/O-FE With MII and RJ-45 Fast Ethernet Ports (with SRAM)

Note In Figure 4, the NVRAM is replaced by an SRAM component (U14) that is made to act like the NVRAM by the addition of some external components, one of which is the button-type lithium battery labeled “Battery for SRAM.”

Note The C7200-I/O-FE I/O controller has reached its end-of-life and is no longer an orderable product as of December 2000.

Your I/O controller without the Fast Ethernet port (C7200-I/O or UBR7200-I/O) might look like Figure 5 (with NVRAM), or it might look like Figure 6 (with SRAM replacing the NVRAM). There is no functional difference between these two I/O controllers without the Fast Ethernet port.

1 Temperature sensor 9 Captive installation screw

2 FPGA configuration PROM (U9) 10 PC Card slots

3 Midplane connectors 11 Optional Fast Ethernet interface (MII port and RJ-45 port)

4 4-MB Flash memory (soldered) (U10–U13) 12 LEDs

5 SRAM (U14) 13 CPU reset button

6 Boot EPROM (U4) 14 Auxiliary port

7 Temperature sensor 15 Console port

8 Battery for SRAM

8452

3

AUX

CONSO

LE

PCMCIA

EJECT

SLOT 0

SLOT

1

FE MII

FAST ETHERNET INPUT/OUTPUT CONTROLLER

RJ45

CPU RESET

MII

EN

RJ45

EN RJ45

LINK

I/O P

WR

OK

ENABLED

10

12

9

131514

1 2 3 4

78

11

65

8Input/Output Controller Replacement Instructions

OL-4447-02

Page 9: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Input/Output Controller Description

Figure 5 C7200-I/O Without Fast Ethernet Port (with NVRAM)

1 Temperature sensor 7 Captive installation screw

2 Midplane connectors 8 PC Card slots

3 Flash SIMM (U99) 9 LED and CPU reset button

4 Boot ROM (U20) 10 Auxiliary port

5 NVRAM (U41) 11 Console port

6 Temperature sensor

9327

7

CPU

RESET

IO P

WR

OK

AUX

CONSO

LE

PCMCIA

EJECT

SLOT 0

SLOT

1 FAST ETHERNET INPUT/OUTPUT CONTROLLER

ENABLED

8

7

1110

1

4

3

56

2

9

9Input/Output Controller Replacement Instructions

OL-4447-02

Page 10: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Input/Output Controller Description

Figure 6 C7200-I/O—Without Fast Ethernet Port (with SRAM)

Note In Figure 6, the NVRAM is replaced by an SRAM component (U14) that is made to act like the NVRAM by the addition of some external components, one of which is the button-type lithium battery labeled “Battery for SRAM.”

1 Temperature sensor 8 Battery for SRAM

2 FPGA configuration PROM (U9) 9 Captive installation screw

3 Midplane connectors 10 PC Card slots

4 4-MB Flash memory (soldered) (U10-U13) 11 LED

5 SRAM (U14) 12 CPU reset button

6 Boot EPROM (U4) 13 Auxiliary port

7 Temperature sensor 14 Console port

8452

4

AUX

CONSO

LE

PCMCIA

EJECT

SLOT 0

SLOT

1 INPUT/OUTPUT CONTROLLER

CPU RESET

I/O P

WR

OK

ENABLED

10

11

9

121413

1 2 3 4

786

5

10Input/Output Controller Replacement Instructions

OL-4447-02

Page 11: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Input/Output Controller Description

Figure 7 C7200-I/O-FE-MII With Single MII Fast Ethernet Port

Note The C7200-I/O-FE-MII I/O controller has reached its end-of-life and is no longer an orderable product as of April 1998.

Table 3 lists the I/O controller memory components.

1 Temperature sensor 7 Captive installation screw

2 Midplane connectors 8 PC Card slots

3 Flash SIMM (U99) 9 Optional Fast Ethernet interface (MII connector)

4 Boot ROM (U20) 10 LEDs and CPU reset button

5 NVRAM (U41) 11 Auxiliary port

6 Temperature sensor 12 Console port

8453

4

FE EN

ABLE

FE LIN

K

CPU

RESET

IO P

WR

OK

AUX

CONSO

LE

PCMCIA

EJECT

SLOT 0

SLOT

1

FE MII

FAST ETHERNET INPUT/OUTPUT CONTROLLER

ENABLED

89

7

1211

1

4

3

56

2

10

Table 3 Input/Output Controller Memory Components

Type Size Quantity Memory Description Model Location

Boot ROM1 256 KB 1 32-pin DIP-type C7200-I/O-FE-MII U20

32-pin DIP-type or 32-pin PLCC-type

C7200-I/O-FE, C7200-I/O

U20 or U4

Flash memory 4 MB 1 Contains the default boot helper (boot loader) image

C7200-I/O-FE-MII U99

C7200-I/O-FE, C7200-I/O

U99or

U10, U11, U12, and U13 (soldered)2

8 MB 1 C7200-I/O-GE+E, C7200-I/O-2FE/E

U13 and U25 (soldered)2

11Input/Output Controller Replacement Instructions

OL-4447-02

Page 12: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Input/Output Controller Description

Table 4 lists the factory-installed Flash memory card options and their product numbers.

Note Flash memory cards are not supported on the C7200-I/O-2FE/E and C7200-I/O-GE+E I/O controllers when an NPE-G1 or NPE-G2 processor is installed.

Flash memory card

20 MB

Up to 2 Contains the default Cisco IOS image

C7200-I/O-FE, C7200-I/O, C7200-I/O-FE-MII

PC Card slot 0 and slot 1

Flash Disk 483, 64, or 128 MB4

All models PC Card disk 0 and disk 1

NVRAM

128 KB 1Nonvolatile EPROM for the system configuration file

C7200-I/O-FE-MII U41

C7200-I/O-FE, C7200-I/O

U41or

U14 (soldered)5

C7200-I/O-GE+E, C7200-I/O-2FE/E

U19 (soldered)5

1. The C7200-I/O-GE+E and C7200-I/O-2FE/E do not have a boot ROM component.

2. Some I/O controllers have no Flash SIMM but use a permanently soldered 4-MB or 8-MB Flash chip instead. (For the 4-MB Flash chip, see Figure 3 and Figure 5 for comparison. For the location of the 8-MB Flash, see Figure 1 and Figure 2.)

3. The 48-MB Flash Disk is scheduled for end-of-life in late 2002 and will be replaced by the 64-MB Flash Disk. Existing 48-MB Flash Disks can continue to be used in all I/O controllers.

4. The UBR7200-I/O-FE controller for the Cisco uBR7200 series routers supports only the 48-MB version of the Flash Disk.

5. The NVRAM on some I/O controllers is replaced by a 32-pin nonsocketed SRAM component that is soldered onto the card. The SRAM component is made to act like the NVRAM by the addition of some external components, one of which is a 1-inch (2.54-cm) button-type lithium battery.

Table 3 Input/Output Controller Memory Components (continued)

Type Size Quantity Memory Description Model Location

Table 4 Flash Memory Card Options1

1. All Flash memory card options have reached end-of-life and are no longer orderable but are supported in legacy installations. For greater versatility and storage space, we recommend upgrading your routers to the available Flash Disk memory options.

Memory Size2

2. Refer to the Cisco AS5800 universal access server documentation listed in the “Related Documentation” section on page 2 for Cisco AS5800 universal access server Flash memory card options.

Product Number

8 MB MEM-I/O-FLC8M

16 MB MEM-I/O-FLC16M

20 MB MEM-I/O-FLC20M

12Input/Output Controller Replacement Instructions

OL-4447-02

Page 13: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Input/Output Controller Description

Table 5 lists the Flash Disk memory options and their product numbers.

LED DescriptionsThe I/O controller faceplate contains LEDs that indicate system and port status; two additional LEDs indicate the status of the Flash Disk or Flash memory cards installed in either PC Card slot. A CPU reset button is located next to the IO power OK LED or next to the auxiliary port on the I/O controller faceplate. The CPU reset button resets the entire system.

Caution To prevent system errors and problems, use the CPU reset button only at the direction of your service representative.

Table 6 lists LEDs common to all models of I/O controllers and describes their functions.

Note LEDs are either on or off. The LED state (on or off), not the color, determines the status of connection. However, most LEDs are green when on, with the exception of the IO POWER OK LED, which is orange when in the ON state.

Table 5 Flash Disk Memory Options

Memory Size Product Number

32 MB MEM-I/O-FLD32M1

1. These products are no longer orderable but are still supported in legacy systems that originally supported them.

40 MB MEM-I/O-FLD40M1

48 MB2

2. The 48-MB Flash Disk is scheduled for end-of-life in late 2002 and will be replaced by the 64 MB Flash Disk. Existing 48 MB Flash Disks can continue to be used in all I/O controllers.

MEM-I/O-FLD48M, MEM-I/O-FLD48M=

64 MB MEM-I/O-FLD64M, MEM-I/O-FLD64M=

110 MB MEM-I/O-FLD110M1

128 MB MEM-I/O-FLD128M, MEM-I/O-FLD128M=

Table 6 I/O Controller LEDs

LED Color Function

ENABLED Green Indicates that the network processing engine or network services engine and the I/O controller are enabled for operation by the system; however, it does not mean that the Fast Ethernet port on the I/O controller is functional or enabled. This LED goes on during a successful router boot and remains on during normal operation of the router.

IO PWR OK or I/O POWER OK

Orange Indicates that the I/O controller is on and receiving DC power from the router midplane. This LED comes on during a successful router boot and remains on during normal operation of the router.

SLOT 0

SLOT 1

Green These LEDs indicate which PC Card slot is in use by coming on when either slot is being accessed by the system. These LEDs remain off during normal operation of the router.

13Input/Output Controller Replacement Instructions

OL-4447-02

Page 14: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Input/Output Controller Description

Input/Output Controller C7200-I/OFigure 8 shows the LEDs on the I/O controller model with no Ethernet ports (C7200-I/O or UBR7200-I/O). This I/O controller has no port-specific LEDs. Table 6 on page 13 describes the LEDs on this I/O controller.

Figure 8 C7200-I/O LEDs and CPU Reset Button

AUX

CONSO

LE

PCMCIA

EJECT

SLOT 0

CPU RESET

IO P

OW

ER

OK

SLOT

1 INPUT/OUTPUT CONTROLLER

H74

01

SLOT 0

SLOT

1

CPU RESET

IO P

OW

ER

OK

ENABLED

ENABLED

AUX

CONSO

LE

PCMCIA

EJECT

SLOT 0

I/O P

WR

OK

SLOT

1 INPUT/OUTPUT CONTROLLER

2593

0

SLOT 0

SLOT

1

CPU RESET

I/O P

WR

OK

ENABLED

ENABLED

CPU RESET

14Input/Output Controller Replacement Instructions

OL-4447-02

Page 15: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Input/Output Controller Description

Input/Output Controller C7200-I/O-GE+EFigure 9 shows the LEDs on the I/O controller with the Gigabit Ethernet port and the Ethernet port (C7200-I/O-GE+E, and Table 7 lists the LEDs specific to this I/O controller model. Table 6 on page 13 lists the LEDs on this controller that are common to all controllers.

Figure 9 C7200-I/O-GE+E LEDs and CPU Reset Button

Table 7 C7200-I/O-GE+E I/O Controller LEDs

LED Color Function

LINK Green Indicates that the Ethernet RJ-45 port has established a valid link with the network. This LED remains on during normal operation of the router.

GBIC EN

(Enable) (Interfaces 0/1, 0/2, 0/3)

Green When the LED is on, the RJ-45 port is selected. When it is off, the GBIC port is selected

CLA

SS 1

LED

PRO

DU

CT

P

RO

DU

KT M

IT K

LASSE 1

LED

PRO

DU

IT A

VEC

VOYA

NT D

EL

D

E C

LASSE 1

PRO

DU

CTO

LED

DE C

LASE 1LIN

KETHERNET GIGABIT ETHERNET INPUT/OUTPUT CONTROLLER

CONSOLEAUX

PORTE 0

LINK

SLOT 0 PORT

GE 0RX TX

EJECT

PCMCIA

SLOT 1

ENABLED

CPU

RESET

IO P

WR

OK

3344

6

CPU

RESET

IO P

WR

OKLIN

K

SLOT 0

SLOT 1

C7200-I/O-GE+E

ENABLED LINK

GBIC

EN

15Input/Output Controller Replacement Instructions

OL-4447-02

Page 16: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Input/Output Controller Description

Input/Output Controller C7200-I/O-2FE/EFigure 10 shows the LEDs on the I/O controller with the two autosensing 10/100-Mbps RJ-45 ports (C7200-I/O-2FE/E or UBR7200-I/O-2FE/E), and Table 8 lists the LEDs specific to this I/O controller model. Table 6 on page 13 lists the LEDs on this controller that are common to all controllers.

Figure 10 C7200-I/O-2FE/E LEDs and CPU Reset Button

Caution To comply with EMI EN55022 Class B regulations, shielded Ethernet cables (p/n 72-1501-01) must be used with the UBR7200-I/O-2FE/E I/O controller in the Cisco uBR7246VXR router. Two shielded cables are included with the UBR7200-I/O-2FE/E controller.

Table 8 C7200-I/O-2FE/E I/O Controller LEDs

LED Color Function

100 Mbps Green Indicates that the port is configured for 100-Mbps operation (speed 100), or if configured for autonegotiation (speed auto), the port has detected a valid link at 100 Mbps.

Note If the port is configured for 10-Mbps operation, or if it is configured for autonegotiation and the port has detected a valid link at 10 Mbps, the LED remains off.

LINK Green Indicates that the Ethernet/Fast Ethernet RJ-45 port has established a valid link with the network. This LED remains off during normal operation of the router unless there is an incoming carrier signal.

DUAL FAST ETHERNET INPUT/OUTPUT CONTROLLER

CONSOLEAUX

100 Mbps

LINK

100 Mbps

LINK

SLOT 0

EJECT

PCMCIA

SLOT 1

ENABLED

CPU

RESET

IO P

WR

OK

3344

4

CPU

RESET

IO P

WR

OK

100 Mbps

LINK

SLOT 0

SLOT 1

C7200-I/O-2FE/E

ENABLED

FE/E 0

FE/E 1

16Input/Output Controller Replacement Instructions

OL-4447-02

Page 17: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Input/Output Controller Description

Input/Output Controller C7200-I/O-FEFigure 11 shows the LEDs on the I/O controller with the Fast Ethernet port that is equipped with an MII port and Figure 12 shows an I/O controller with an RJ-45 port (C7200-I/O-FE). Table 9 lists the LEDs specific to this I/O controller model. Table 6 on page 13 lists the LEDs on this controller that are common to all controllers.

Note The C7200-I/O-FE I/O controller has reached its end-of-life and is no longer an orderable product as of December 2000.

Figure 11 C7200-I/O-FE LEDs and CPU Reset Button

Figure 12 C7200-I/O-FE LEDs and CPU Reset Button (RJ-45)

H11

294

SLOT 1

SLOT 0

FAST ETHERNET INPUT/OUTPUT CONTROLLER

RJ-45

CPU RESET

MII

EN RJ45

EN RJ45

LINK

IO P

WR

OK

MII

EN RJ45

EN RJ45

LINK

IO P

WR

OK

CPU RESET

ENABLED

ENABLED

AUX

CONSO

LE

PCMCIA

EJECT

SLOT 0

SLOT

1

FE MII

FAST ETHERNET INPUT/OUTPUT CONTROLLER

RJ45

CPU RESET

MII

EN

RJ45

EN RJ45

LINK

I/O P

WR

OK

2592

9

SLOT 1

SLOT 0M

II EN

RJ45

EN RJ45

LINK

I/O P

WRO

K

CPU RESET

ENABLED

ENABLED

17Input/Output Controller Replacement Instructions

OL-4447-02

Page 18: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Input/Output Controller Description

Note An MII LINK LED is not provided on this I/O controller because the LED is provided on external transceivers that are required for connecting to the MII port on the I/O controller. See the “Ethernet and Fast Ethernet RJ-45 Connection Equipment” section on page 64 for Fast Ethernet MII connection requirements.

Input/Output Controller C7200-I/O-FE-MIIFigure 13 shows the LEDs on the I/O controller with the Fast Ethernet port equipped with a single MII port (C7200-I/O-FE-MII), and Table 10 lists the LEDs specific to this I/O controller model. Table 6 on page 13 lists the LEDs on this controller that are common to all controllers.

Note The C7200-I/O-FE-MII I/O controller has reached its end-of-life and is no longer an orderable product as of April 1998.

Table 9 C7200-I/O-FE I/O Controller LEDs

LED Color Function

MII EN Green Indicates that the Fast Ethernet MII port is initialized and enabled by the system, and is configured for operation. This LED comes on after the I/O controller has been enabled and the MII port has been configured as the media type for the Fast Ethernet port. (The RJ-45 port is the default media type for the Fast Ethernet port.) This LED remains on during normal operation of the router.

This LED is disabled by the system software when the I/O controller with the Fast Ethernet port is installed in a Cisco 7202.

RJ45 EN Green Indicates that the Fast Ethernet RJ-45 port (the default media type for the Fast Ethernet port) is initialized and enabled by the system. This LED comes on after the I/O controller has been enabled and remains on during normal operation of the router.

This LED is disabled by the system software when the I/O controller with the Fast Ethernet port is installed in a Cisco 7202.

RJ45 LINK Green Indicates that the Fast Ethernet RJ-45 port has established a valid link with the network. This LED remains off during normal operation of the router unless there is an incoming carrier signal.

This LED is disabled by the system software when the I/O controller with the Fast Ethernet port is installed in a Cisco 7202.

18Input/Output Controller Replacement Instructions

OL-4447-02

Page 19: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Installation Prerequisites

Figure 13 C7200-I/O-FE-MII LEDs and CPU Reset Button

Installation PrerequisitesThis section provides a list of parts and tools you need to remove and replace the I/O controller in Cisco 7200 series routers or Cisco uBR7200 series routers. This section also includes safety and ESD-prevention guidelines to help you avoid injury to yourself and damage to the equipment.

List of Parts and ToolsYou need the following parts and tools to remove and replace the I/O controller. If you need additional equipment, contact a service representative for ordering information:

• New I/O controller

• Number 2 Phillips screwdriver and a 3/16-inch flat-blade screwdriver

• 8-mm wrench or nut driver, or adjustable wrench (for connecting a grounding lug to a Cisco uBR7200 series DC-input power supply)

Table 10 C7200-I/O-FE-MII I/O Controller LEDs

LED Color Function

FE ENABLE Green Indicates that the Fast Ethernet port is initialized and enabled for operation by the system. This LED comes on after the I/O controller has been enabled and remains on during normal operation of the router.

This LED is disabled by the system software when the I/O controller with the Fast Ethernet port is installed in a Cisco 7202.

FE LINK Green Indicates that the Fast Ethernet port has established a valid link with the network. This LED remains off during normal operation of the router unless there is an incoming carrier signal.

This LED is disabled by the system software when the I/O controller with the Fast Ethernet port is installed in a Cisco 7202.

H65

23

FE

ENABLE

SLOT 1

SLOT 0 FE L

INK

CPU RESET

IO P

OWER O

K

FAST ETHERNET INPUT/OUTPUT CONTROLLER

ENABLED

ENABLED

19Input/Output Controller Replacement Instructions

OL-4447-02

Page 20: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Installation Prerequisites

• 7-mm wrench or nut driver, or adjustable wrench (for connecting the DC-input power lead strain-relief cover to a DC-input power supply)

• Tape (for securing the switch handle of a DC circuit breaker in the OFF position)

• Your own ESD-prevention equipment or the disposable grounding wrist strap included with all upgrade kits, field-replaceable units (FRUs), and spares

• Antistatic mat or surface, or static shielding bag

• Small pliers

Software and Hardware RequirementsTable 11 lists the recommended minimum Cisco IOS software release (and boot helper [boot loader] image) to use with the I/O controller in supported router platforms.

20Input/Output Controller Replacement Instructions

OL-4447-02

Page 21: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Installation Prerequisites

Table 11 I/O Controller Minimum Software and Boot Helper (Boot Loader) Image Requirements

Router Platform

Input/Output Controller

C7200-I/O and C7200-I/O-FE C7200-I/O-2FE/E C7200-I/O-GE+E

Cisco 7200 series

Cisco 7204VXR and Cisco 7206VXR

Cisco IOS Release 12.0(2)XE2

Cisco IOS Release 12.0(3)T or later releases

Cisco IOS Release 12.2(4)B or later releases

Cisco IOS Release 12.1(3a)E or later releases

Cisco IOS Release 12.1(5)T or later releases

Cisco IOS Release 12.0(14)S or later releases

Cisco IOS Release 12.2(4)B or later releases

Note Use the c7200-kboot-mz image as your boot helper (boot loader) image for C7200-I/O-2FE/E.

Cisco IOS Release 12.1(3a)E or later releases

Cisco IOS Release 12.1(5)T or later releases

Cisco IOS Release 12.0(14)S or later releases

Cisco IOS Release 12.2(4)B or later releases

Note Use the c7200-kboot-mz image as your boot helper (boot loader) image for C7200-I/O-GE+E.

Cisco 7200 Cisco IOS Release 11.1(17)CA or later releases

Cisco IOS Release 11.2(12)P or later releases

Cisco IOS Release 11.3(2)T or later releases

Cisco IOS Release 11.3(2)AA or later releases

Cisco IOS Release 12.2(4)B or later releases

Not supported Not supported

Cisco 7204 Cisco IOS Release 11.1(17)CA or later releases

Cisco IOS Release 11.2(12)P or later releases

Cisco IOS Release 11.3(2)T or later releases

Cisco IOS Release 11.3(2)AA or later releases

Not supported Not supported

Cisco 72021 Cisco IOS Release 11.1(19)CC1 or later releases

Cisco IOS Release 11.3(4)AA or later releases

Not supported Not supported

Cisco AS5800 Universal Access Server2

Cisco 7206 router shelf Cisco IOS Release 11.3(2)AA or later releases

Not supported Not supported

21Input/Output Controller Replacement Instructions

OL-4447-02

Page 22: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Installation Prerequisites

Depending on the I/O controller model you have, the hardware requirements in the following sections apply.

Cisco 7206VXR router shelf

Cisco IOS Release 12.0(4)XJ or later releases

Not supported Not supported

Cisco uBR7200 series3, 4

Cisco uBR7246VXR Cisco IOS Release 12.0(6)SC or later releases5

Cisco IOS Release 12.1(3a)EC1 or later releases

Cisco IOS Release 12.2(4)BC1 or later releases

Cisco IOS Release 12.1(10)EC or later releases

Cisco IOS Release 12.2(4)BC1 or later releases

Note Use only the Cisco IOS Release 12.1(10)EC or later ubr7200-boot-mz image (ubr7200-boot-mz.121-10.EC) as your boot helper (boot loader) image for the UBR7200-I/O-2FE/E.6

Not supported

Cisco uBR7246 and Cisco uBR7223

Cisco IOS Release 11.3(6)NA or later releases5

Cisco IOS Release 12.0(6)SC or later releases

Cisco IOS Release 12.1(3a)EC1 or later releases

Cisco IOS Release 12.2(4)BC1 or later releases

Not supported Not supported

1. You can install an I/O controller with or without a Fast Ethernet port in a Cisco 7202; however, when you install an I/O controller with a Fast Ethernet port, the Cisco 7202 system software automatically disables the port.

2. The Cisco 7206 and Cisco 7206VXR can be used as router shelves in a Cisco AS5800 universal access server. For information about the Cisco AS5800 universal access server, refer to the Cisco AS5800 universal access server documentation listed in the “Related Documentation” section on page 2.

3. If you need to order a spare I/O controller for a Cisco uBR7200 series router, use the Cisco uBR7200 series product number followed by an equal sign (=). These I/O controllers have the Cisco uBR7200 series boot helper (boot loader) image loaded on the Flash SIMMs. (For Cisco uBR7200 series product numbers, see Table 2.)

4. Initial shipments of the Cisco uBR7246 chassis that were equipped with a Fast Ethernet I/O controller might have an I/O controller with the single MII port installed. These I/O controllers are fully compatible with the router. If you need to order a spare I/O controller, use the product numbers described in the previous footnote.

5. To support the UBR7200-I/O-FE, the Cisco uBR7200 series routers can use any previous boot image that supports a supported version of Cisco IOS software. However, we recommend using the Cisco IOS Release 12.0(15)SC [ubr7200-boot-mz.12.0-15.SC] boot image for maximum feature support.

6. The Cisco IOS Release 12.1(10)EC or later Cisco IOS Release 12.1 EC boot image must be used only on a Cisco uBR7246VXR using the UBR7200-I/O-2FE/E controller. This boot helper image must not be used for any Cisco uBR7200 series router using the UBR7200-I/O-FE controller.

Table 11 I/O Controller Minimum Software and Boot Helper (Boot Loader) Image Requirements (continued)

Router Platform

Input/Output Controller

C7200-I/O and C7200-I/O-FE C7200-I/O-2FE/E C7200-I/O-GE+E

22Input/Output Controller Replacement Instructions

OL-4447-02

Page 23: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Installation Prerequisites

C7200-I/O-2FE/E I/O Controller

The C7200-I/O-2FE/E I/O controller operates only in the Cisco 7204VXR and Cisco 7206VXR routers, and in the Cisco uBR7246VXR universal broadband router.

• The C7200-I/O-2FE/E I/O controller is not supported in conjunction with the NPE-100 or NPE-150, because these network processing engines (NPEs) require that there be a boot ROM present on the I/O controller; however, the C7200-I/O-2FE/E I/O controller does not have a boot ROM component.

• The C7200-I/O-2FE/E I/O controller is not supported in conjunction with the NPE-200, because operational behavior with this NPE is unpredictable.

• The C7200-I/O-2FE/E I/O controller operates with the following: NPE-225, NPE-300, NPE-400, NPE-G1, NPE-G2, and NSE-1 only.

Note The C7200-I/O-2FE/E I/O controller operates only with this version of the NPE-225: board label 73-3453-05 rev. A0 or higher, or faceplate label 800-05418-03 rev. A0 or higher.

To check for the correct NPE-225 version in software, use the show c7200 command. Under CPU EEPROM, look for Hardware Revision 1.3 or higher.

Note The NPE-300 has reached its end-of-life and is no longer orderable as of November 15, 2001.

• The C7200-I/O-2FE/E I/O controller operates with the NPE-G1 and NPE-G2, but an I/O controller is not necessary because the NPE-G1 and NPE-G2 contain their own onboard controller. Installing an I/O controller in a chassis with the NPE-G1 or NPE-G2 activates the console and auxiliary ports on the I/O controller and automatically disables the console and auxiliary ports on board the NPE-G1 or NPE-G2. However, you can still use the Flash Disk slots and Ethernet ports on both the NPE-G1 or NPE-G2 and I/O controller when both cards are installed.

• To comply with EMI EN55022 Class B regulations, shielded Ethernet cables (p/n 72-1501-01) must be used with the UBR7200-I/O-2FE/E controller in the Cisco uBR7246VXR router.

• The C7200-I/O-2FE/E I/O controller is not supported in conjunction with the NPE-175. When you install a C7200-I/O-2FE/E I/O controller in a system that is using an NPE-175, the system software automatically disables the ports on the I/O controller.

Additionally, the following error message appears in the system banner at bootup:

PA-3-NOTSUPPORTED: PA in slot0 (Dual FastEthernet/Ethernet (with GBIC/RJ45) I/O Card) is not supported on this chassis or npe cpu card

Note The C7200-I/O-2FE/E controller requires the c7200-kboot-mz boot helper image, and the UBR7200-I/O-2FE/E I/O controller requires the ubr7200-kboot-mz boot helper image. Attempting to use the standard boot image results in no network boot interfaces with the following warning message displayed:

%c7200-3-IONOTSUPPORTEDBYLOADER: I/O controller (type 539) is not supported by

this boot loader. The I/O controller network interfaces will be unavailable.

23Input/Output Controller Replacement Instructions

OL-4447-02

Page 24: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Installation Prerequisites

C7200-I/O-GE+E I/O Controller

The C7200-I/O-GE+E I/O controller operates only in the Cisco 7204VXR and Cisco 7206VXR routers

• The C7200-I/O-GE+E I/O controller is not supported in conjunction with the NPE-100 or NPE-150, because these network processing engines (NPEs) require that there be a boot ROM present on the I/O controller; however, the C7200-I/O-GE+E I/O controller does not have a boot ROM component.

• The C7200-I/O-GE+E I/O controller is not supported in conjunction with the NPE-200, because operational behavior with this NPE is unpredictable.

The Cisco C7200-I/O-GE+E I/O controller operates with the following NPEs and network services engine (NSE) only on the Cisco 7204VXR and Cisco 7206VXR routers: NPE-300, NPE-400, NPE-G1, and NSE-1.

Note The C7200-I/O-GE+E I/O controller operates with the NPE-G1, but an I/O controller is not necessary because the NPE-G1 contains its own onboard controller. Installing an I/O controller in a chassis with the NPE-G1 activates the console and auxiliary ports on the I/O controller and automatically disables the console and auxiliary ports on board the NPE-G1. However, you can still use the Flash Disk slots and Ethernet ports on both the NPE-G1 and I/O controller when both cards are installed.

• The C7200-I/O-GE+E I/O controller is not supported in conjunction with the NPE-175 and NPE-225. When you install a C7200-I/O-GE+E I/O controller in a system that is using an NPE-175 or an NPE-225, the system software automatically disables the ports on the I/O controller.

Additionally, the following error message appears in the system banner at bootup:

PA-3-NOTSUPPORTED: PA in slot0 (GigabitEthernet/Ethernet (with GBIC/RJ45) I/O Card) is not supported on this chassis or npe cpu card

Note The C7200-I/O-GE+E I/O controller requires the c7200-kboot-mz boot helper image. Attempting to use the standard boot image results in no network boot interfaces with the following warning message displayed:

%c7200-3-IONOTSUPPORTEDBYLOADER: I/O controller (type 539) is not supported by this boot

loader. The I/O controller network interfaces will be unavailable.

C7200-I/O-FE=, C7200-I/O-MII=, or C7200-I/O= I/O Controllers

You can install the C7200-I/O-FE, C7200-I/O-MII, or C7200-I/O in all Cisco 7200 series routers (including the Cisco 7206 and Cisco 7206VXR as router shelves in a Cisco AS5800 universal access server); however, when you install an I/O controller with a Fast Ethernet port in a Cisco 7202, the system software automatically disables the port.

• These I/O controllers also operate with the NPE-G1 on a VXR chassis, but an I/O controller is not necessary because the NPE-G1 contains its own onboard controller. Installing an I/O controller in a chassis with the NPE-G1 activates the console and auxiliary ports on the I/O controller and automatically disables the console and auxiliary ports on board the NPE-G1. However, you can still use the Flash Disk slots and Ethernet ports on both the NPE-G1 and I/O controller when both cards are installed.

• For the Cisco 7202, the following message appears in the system banner if an I/O controller with the Fast Ethernet port is installed in the system:

%C7200-3-UNSUPPORTED: FE in slot0 is not supported on C7202 chassis

24Input/Output Controller Replacement Instructions

OL-4447-02

Page 25: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Installation Prerequisites

If the above message appears, the Fast Ethernet port on the I/O controller is automatically disabled. If the above message does not appear, your Cisco 7202 has an installed I/O controller without the Fast Ethernet port.

• When you use the I/O controller that is equipped with an MII port and an RJ-45 port (C7200-I/O-FE), only one port can be configured for use at a time.

• If you order an I/O controller as a spare for a Cisco uBR7200 series router, use the Product Numbers listed in Table 2 for the Cisco uBR7200 series. These I/O controllers have the boot helper (boot loader) image used by a Cisco uBR7200 series router loaded on the Flash memory SIMMs. Cisco 7200 series I/O controller spares (C7200-I/O-FE-MII=, C7200-I/O-FE=, and C7200-I/O=) do not have the Cisco uBR7200 series boot helper image loaded on the Flash memory SIMMs.

• The C7200-I/O-FE-MII I/O controller has reached its end-of-life and is no longer an orderable product as of April 1998. The C7200-I/O-FE I/O controller has reached its end-of-life and is no longer an orderable product as of December 2000.

• The UBR7200-I/O-FE controller for the Cisco uBR7200 series routers supports only the 48 MB version of the Flash Disk.

Note Certain Cisco hardware products have incorporated a hardware change that is transparent for most users. However, an anomaly has been identified when this updated Cisco hardware is used in conjunction with certain releases of Cisco IOS software. (See the “Troubleshooting Using the show interfaces fastethernet Command” section on page 60 for an explanation of this anomaly and a workaround procedure.)

Safety GuidelinesFollowing are safety guidelines that you should follow when working with any equipment that connects to electrical power or telephone wiring.

25Input/Output Controller Replacement Instructions

OL-4447-02

Page 26: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Installation Prerequisites

Safety Warnings

Warning IMPORTANT SAFETY INSTRUCTIONS

This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071

SAVE THESE INSTRUCTIONS

Waarschuwing BELANGRIJKE VEILIGHEIDSINSTRUCTIES

Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van de standaard praktijken om ongelukken te voorkomen. Gebruik het nummer van de verklaring onderaan de waarschuwing als u een vertaling van de waarschuwing die bij het apparaat wordt geleverd, wilt raadplegen.

BEWAAR DEZE INSTRUCTIES

Varoitus TÄRKEITÄ TURVALLISUUSOHJEITA

Tämä varoitusmerkki merkitsee vaaraa. Tilanne voi aiheuttaa ruumiillisia vammoja. Ennen kuin käsittelet laitteistoa, huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu onnettomuuksien yleisiin ehkäisytapoihin. Turvallisuusvaroitusten käännökset löytyvät laitteen mukana toimitettujen käännettyjen turvallisuusvaroitusten joukosta varoitusten lopussa näkyvien lausuntonumeroiden avulla.

SÄILYTÄ NÄMÄ OHJEET

Attention IMPORTANTES INFORMATIONS DE SÉCURITÉ

Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant entraîner des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers liés aux circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions des avertissements figurant dans les consignes de sécurité traduites qui accompagnent cet appareil, référez-vous au numéro de l'instruction situé à la fin de chaque avertissement.

CONSERVEZ CES INFORMATIONS

Warnung WICHTIGE SICHERHEITSHINWEISE

Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.

BEWAHREN SIE DIESE HINWEISE GUT AUF.

26Input/Output Controller Replacement Instructions

OL-4447-02

Page 27: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Installation Prerequisites

Avvertenza IMPORTANTI ISTRUZIONI SULLA SICUREZZA

Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di intervenire su qualsiasi apparecchiatura, occorre essere al corrente dei pericoli relativi ai circuiti elettrici e conoscere le procedure standard per la prevenzione di incidenti. Utilizzare il numero di istruzione presente alla fine di ciascuna avvertenza per individuare le traduzioni delle avvertenze riportate in questo documento.

CONSERVARE QUESTE ISTRUZIONI

Advarsel VIKTIGE SIKKERHETSINSTRUKSJONER

Dette advarselssymbolet betyr fare. Du er i en situasjon som kan føre til skade på person. Før du begynner å arbeide med noe av utstyret, må du være oppmerksom på farene forbundet med elektriske kretser, og kjenne til standardprosedyrer for å forhindre ulykker. Bruk nummeret i slutten av hver advarsel for å finne oversettelsen i de oversatte sikkerhetsadvarslene som fulgte med denne enheten.

TA VARE PÅ DISSE INSTRUKSJONENE

Aviso INSTRUÇÕES IMPORTANTES DE SEGURANÇA

Este símbolo de aviso significa perigo. Você está em uma situação que poderá ser causadora de lesões corporais. Antes de iniciar a utilização de qualquer equipamento, tenha conhecimento dos perigos envolvidos no manuseio de circuitos elétricos e familiarize-se com as práticas habituais de prevenção de acidentes. Utilize o número da instrução fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham este dispositivo.

GUARDE ESTAS INSTRUÇÕES

¡Advertencia! INSTRUCCIONES IMPORTANTES DE SEGURIDAD

Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considere los riesgos de la corriente eléctrica y familiarícese con los procedimientos estándar de prevención de accidentes. Al final de cada advertencia encontrará el número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo.

GUARDE ESTAS INSTRUCCIONES

Varning! VIKTIGA SÄKERHETSANVISNINGAR

Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanliga förfaranden för att förebygga olyckor. Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna anordning.

SPARA DESSA ANVISNINGAR

27Input/Output Controller Replacement Instructions

OL-4447-02

Page 28: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Installation Prerequisites

Electrical Equipment Guidelines

Follow these basic guidelines when working with any electrical equipment:

• Before beginning any procedures requiring access to the chassis interior, locate the emergency power-off switch for the room in which you are working.

• Disconnect all power and external cables before moving a chassis.

• Do not work alone when potentially hazardous conditions exist.

• Never assume that power has been disconnected from a circuit; always check.

• Do not perform any action that creates a potential hazard to people or makes the equipment unsafe.

28Input/Output Controller Replacement Instructions

OL-4447-02

Page 29: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Installation Prerequisites

• Carefully examine your work area for possible hazards such as moist floors, ungrounded power extension cables, and missing safety grounds.

Telephone Wiring Guidelines

Use the following guidelines when working with any equipment that is connected to telephone wiring or to other network cabling:

• Never install telephone wiring during a lightning storm.

• Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.

• Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.

• Use caution when installing or modifying telephone lines.

Electrostatic Discharge Prevention

Electrostatic discharge (ESD) damages equipment and impairs electrical circuitry. ESD occurs when printed circuit boards are improperly handled and results in complete or intermittent failures.

The network processing engine or network services engine, I/O controller, port adapters, and Cisco uBR7200 series cable modem cards consist of a printed circuit board that is fixed in a metal carrier. Electromagnetic interference (EMI) shielding, connectors, and a handle are integral components of the carrier. Handle the network processing engine or network services engine, I/O controller, port adapters, and Cisco uBR7200 series cable modem cards by their carrier edges and handles; never touch the printed circuit board or connector pins.

Figure 14 shows the location of a printed circuit board in a network processing engine, network services engine, I/O controller, or Cisco uBR7200 series cable modem card metal carrier. Do not touch the printed circuit board when handling any of the components.

Figure 14 Handling the Network Processing Engine or Network Services Engine, the I/O

Controller, and the Cisco uBR7200 Series Cable Modem Cards—Side View

Figure 15 shows the location of a printed circuit board in a port adapter metal carrier. Do not touch the printed circuit board when handling a port adapter.

1 Printed circuit board 2 Metal carrier

H64

19

1

2

29Input/Output Controller Replacement Instructions

OL-4447-02

Page 30: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Installation Prerequisites

Figure 15 Handling a Port Adapter—Side View

Although the metal carrier helps to protect the printed circuit boards from ESD, wear a preventive antistatic strap whenever handling the network processing engine or network services engine, I/O controller, port adapters, or Cisco uBR7200 series cable interface line cards. Ensure that the strap makes good skin contact, and connect the strap’s clip to an unpainted chassis surface to safely channel unwanted ESD voltages to ground.

If no wrist strap is available, ground yourself by touching the metal part of the chassis.

Caution Make sure to tighten the captive installation screws on the network processing engine or network services engine, Cisco uBR7200 series cable modem cards, and the I/O controller (use a number 2 Phillips or a 3/16-inch flat-blade screwdriver). These screws prevent accidental removal, provide proper grounding for the router, and help to ensure that the network processing engine or network services engine, Cisco uBR7200 series cable modem cards, and the I/O controller are properly seated in the router midplane.

Following are guidelines for preventing ESD damage:

• Always use an ESD wrist strap or ankle strap when installing or replacing the network processing engine or network services engine, I/O controller, port adapters, or Cisco uBR7200 series cable modem cards. Ensure that the ESD strap makes contact with your skin.

• Handle the network processing engine or network services engine, I/O controller, port adapters, or Cisco uBR7200 series cable modem cards by their metal carrier edges and handles only; avoid touching the printed circuit board components or any connector pins.

• When removing the network processing engine or network services engine, I/O controller, port adapters, or Cisco uBR7200 series cable modem cards, place them on an antistatic surface with the printed circuit board components facing upward, or in a static shielding bag. If you are returning an I/O controller, network processing engine or network services engine, port adapter, or Cisco uBR7200 series cable modem card to the factory, immediately place it in a static shielding bag.

Caution Periodically check the resistance value of the antistatic strap. The measurement should be within the range of 1 and 10 megohms (Mohms).

1 Metal carrier 2 Printed circuit board

6642

7

1

2

30Input/Output Controller Replacement Instructions

OL-4447-02

Page 31: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

Removing and Replacing the Input/Output Controller

Warning Only trained and qualified personnel should be allowed to install or replace this equipment. Statement 1030

To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

The following sections explain how to remove and replace an I/O controller in Cisco 7200 series routers or Cisco uBR7200 series routers:

• Copying the Configuration File to a TFTP Server, page 31

• Powering Down the Router and Disconnecting Input Power, page 33

• Removing the Input/Output Controller, page 39

• Replacing an Input/Output Controller, page 41

• Reconnecting Input Power and Powering Up the Router, page 42

• Downloading the Saved Configuration from the TFTP Server, page 50

Note The procedures for removing and replacing an I/O controller in all Cisco 7200 series routers are the same. Therefore, the illustrations and procedures in the following sections apply to Cisco 7200 VXR routers and Cisco 7200 routers (including the Cisco 7206 and 7206VXR as router shelves in the Cisco AS5800 universal access server) unless indicated otherwise.

The procedures for removing and replacing an I/O controller in Cisco uBR7200 series routers are the same as for the platforms mentioned above; however, to show differences in the chassis and I/O controller location, separate illustrations are provided for Cisco uBR7200 series routers.

Copying the Configuration File to a TFTP ServerBefore you replace the I/O controller, be sure to copy the router running configuration to a TFTP file server so that you can retrieve it later; otherwise, you will have to reenter your configuration manually.

Before copying the router configuration file to a TFTP file server, check the following items:

• A console terminal is connected to the console port on the I/O controller, or a Telnet session is established to the router.

• The router is connected to a network supporting a file server (remote host).

• The remote host supports the TFTP application.

• You have the name or address of the remote host.

To copy the router’s configuration file to a remote host, complete the following steps:

Step 1 Make sure you are at the privileged level of the EXEC command interpreter (check the system prompt for a pound sign [#]). If the system prompt does not have a pound sign (#), enter enable, and then your password.

Step 2 Use the ping command to check the connection between the router and the remote host.

31Input/Output Controller Replacement Instructions

OL-4447-02

Page 32: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

Step 3 Enter the show running-config command to display the router’s running configuration. Ensure that the configuration information is complete and correct. If it is not, use the configure command to add or modify the existing configuration. Then enter the copy running-config startup-config command to save the retrieved configuration in NVRAM. NVRAM uses lithium batteries to maintain its contents when disconnected from power.

Note Refer to the appropriate software documentation listed in the “Related Documentation” section on page 2 for descriptions of the configuration options available for the system and individual interfaces, and for specific configuration instructions.

Step 4 Enter the copy startup-config tftp command. The EXEC command interpreter prompts you for the name or IP address of the remote host that is to receive the configuration file. (The prompt might include the name or address of a default file server.)

Router# copy startup-config tftpRemote host []?

Step 5 Enter the name or IP address of the remote host. In the following example, the name of the remote host is servername:

Router# copy startup-config tftpRemote host []? servernameTranslating "servername"...domain server (10.1.1.1) [OK]

Step 6 The EXEC command interpreter prompts you for the name of the file that will contain the configuration. By default, the system appends -confg to the router’s name to create the new filename. Press Return to accept the default filename, or enter a different name for the file before pressing Return. In the following example, the default is accepted:

Name of configuration file to write [Router-confg]?Write file Router-confg on host 10.1.1.1? [confirm]Writing Router-confg.....

Step 7 Before the router executes the copy process, it displays the instructions you entered for confirmation. If the instructions are not correct, enter n (no), and press Return to stop the process. To accept the instructions, press Return, or y, and then Return; the system begins the copy process. In the following example, the default is accepted:

Write file Router-confg on host 10.1.1.1? [confirm]Writing Router-confg: !!!! [ok]

While the router copies the configuration to the remote host, it displays a series of exclamation points (!!!) or periods (. . .). The series of exclamation points (!!!!) and [ok] indicate that the operation is successful. A display of periods (. . .) and [timed out] or [failed] indicates a failure, which would probably be because of a network fault or the lack of a writable, readable file on the remote file server.

Step 8 Check the result of the copy process.

• If the display indicates that the process was successful (with the series of exclamation points (! ! !) and [ok]), the copy process is complete. The configuration file is safely stored in the temporary file on the remote file server.

• If the display indicates that the process failed (with the series of periods ( . . .) as shown in the following example) your configuration was not saved:

Writing Router-confg .....

32Input/Output Controller Replacement Instructions

OL-4447-02

Page 33: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

Step 9 If your configuration was not saved, repeat the preceding steps, or select a different remote file server and repeat the preceding steps. If you are unable to copy the configuration to a remote host successfully, contact your network administrator or see the “Obtaining Documentation and Submitting a Service Request” section on page 82 for instructions on contacting technical assistance.

This completes the procedure for copying the configuration file to a TFTP server. Proceed to the next section, “Powering Down the Router and Disconnecting Input Power.”

Powering Down the Router and Disconnecting Input PowerComplete the steps in the following sections to power down the router and disconnect input power.

Warning This unit might have more than one power cord. To prevent the risk of electric shock, disconnect the two power cords before servicing the unit. Statement 83

To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

Powering Down the Router

To power down a Cisco 7200 series router or Cisco uBR7200 series router, complete the following steps:

Step 1 At the rear of the router, place the power switch on the power supply in the OFF (O) position. Repeat this action if a second power supply is installed in the router.

Step 2 Observe the following items:

• The green OK LED on the power supply goes off.

• The fans stop operating.

• The LEDs on the I/O controller go off.

• The LEDs on the port adapters go off.

• On a Cisco uBR7200 series router, the LEDs on the cable modem cards go off.

Caution When the power switch on a Cisco uBR7200 series power supply is turned to the OFF (O) position, the power supply enters a reset cycle for 90 seconds. Wait at least 90 seconds before turning the power switch back to the ON (|) position. If you do not wait the full 90 seconds, the power supply will not restart.

Caution Wait at least 30 seconds before powering on a Cisco 7200 series router, after you have powered it off.

This completes the procedure for powering down a Cisco 7200 series router or Cisco uBR7200 series router.

33Input/Output Controller Replacement Instructions

OL-4447-02

Page 34: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

Disconnecting AC-Input Power

To disconnect AC-input power from a Cisco 7200 series router or Cisco uBR7200 series router, complete the following steps:

Step 1 Unplug the input power cable from the power source.

Step 2 Unlock the cable-retention clip.

• On a Cisco 7200 series router, push up on the cable-retention clip that secures the input power cable to the router power supply.

• On a Cisco uBR7200 series router, push the cable-retention clip to the left.

Step 3 Unplug the other end of the input power cable from the power supply. (For a Cisco 7200 series router, see Figure 16. For a Cisco uBR7200 series router, see Figure 17.)

Figure 16 Disconnecting Power from a Cisco 7200 Series AC-Input Power Supply

1 Chassis grounding receptacles 6 Network processing engine or network services engine

2 Power supply filler plate 7 AC-input power supply

3 Power switch 8 PWR OK LED

4 AC-input power cable-retention clip 9 AC-input power supply receptacle

5 Internal fans

8439

6

NETWORK PROCESSING ENGINE-300

1 5

243

8 976

34Input/Output Controller Replacement Instructions

OL-4447-02

Page 35: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

Figure 17 Disconnecting Power from a Cisco uBR7200 Series AC-Input Power Supply

(Cisco uBR7246 Shown)

Step 4 Repeat Step 1 through Step 3 if a second power supply is installed.

This completes the procedure for disconnecting AC-input power from a Cisco 7200 series router or Cisco uBR7200 series router.

Disconnecting DC-Input Power

Before completing any of the following steps, and to prevent short-circuit or shock hazards, ensure that power is removed from the DC circuit. To ensure that all power is off, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the off position, and tape the switch handle of the circuit breaker in the off position.

Warning When installing the unit, the ground connection must always be made first and disconnected last. Statement 42To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

To disconnect DC-input power from a Cisco 7200 series router or Cisco uBR7200 series router, complete the following steps:

1 AC-input power receptacle 4 Network processing engine

2 Power switch 5 AC-input power supply

3 Handle

6643

4

3

4

21

5

35Input/Output Controller Replacement Instructions

OL-4447-02

Page 36: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

Step 1 Turn off the power source and disconnect the –V and +V leads from the power source. You can leave the ground cable connected.

Step 2 Remove the devices securing the –V and +V leads:

• For a Cisco 7200 series router, remove the cable tie that secures the –V, +V, and ground leads to the power supply faceplate. Save the cable tie.

Note The cable tie that accompanied your Cisco 7200 series DC-input power supply can be removed and replaced on the power supply without the use of a tool. If you secured the DC-input power supply leads to the power supply faceplate using a different type of cable tie, use a wire stripper to cut that cable tie from the power supply.

• For a Cisco uBR7200 series router, use a 7-mm wrench or nut driver (or adjustable wrench) to loosen and remove the two M4 nuts from the strain-relief cover that secures the –V and +V leads to the power supply faceplate. Remove the strain-relief cover. (See Figure 18.)

Figure 18 Removing the Strain-Relief Cover from a Cisco uBR7200 Series DC-Input

Power Supply

1 Power switch 6 –V lead

2 Power receptacle 7 +V lead

3 Captive installation screw 8 Strain-relief cover

4 M5 grounding receptacles 9 M4 nuts

5 M5 grounding lug

6640

8

3

5 7

6

8

1 2

9

4

36Input/Output Controller Replacement Instructions

OL-4447-02

Page 37: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

Step 3 Using a 3/16-inch flat-blade screwdriver, loosen the screw below the +V lead receptacle, and pull the lead from the connector. (For a Cisco 7200 series router, see Figure 19. For a Cisco uBR7200 series router, see Figure 20.)

• For Cisco 7200 series routers, repeat this step for the –V lead and the ground lead.

• For Cisco uBR7200 series routers, repeat this step for the –V lead only. Using an 8-mm wrench or nut driver (or adjustable wrench), loosen and remove the two M5 nuts that secure the two-hole grounding lug to the grounding receptacle, and pull the grounding lug and lead from the receptacle.

Note The color coding of the DC-input power supply leads depends on the color-coding of the DC power source at your site. Typically, green or green/yellow is used for ground, black is used for +V (return), and red or white is used for –V. Make certain that the lead color-coding you choose for the DC-input power supply matches the lead color-coding used at the DC power source.

Figure 19 Disconnecting Power from a Cisco 7200 Series DC-Input Power Supply

1 Power switch 3 Cable tie

2 Ground lead service loop 4 DC power leads

6643

2

2

1

3

4

37Input/Output Controller Replacement Instructions

OL-4447-02

Page 38: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

Figure 20 Disconnecting Power from a Cisco uBR7200 Series DC-Input Power Supply

Step 4 Repeat Step 1 through Step 3 if a second power supply is installed.

This completes the procedure for disconnecting DC-input power from a Cisco 7200 series router or Cisco uBR7200 series router.

1 Power switch 6 –V lead

2 Power receptacle 7 M4 studs

3 DC power supply 8 +V lead

4 M5 grounding receptacles 9 Handle

5 M5 grounding lug66

406

3

8

1 2

9

7

5 6

4

38Input/Output Controller Replacement Instructions

OL-4447-02

Page 39: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

Removing the Input/Output Controller

Note Before removing the I/O controller, save the router configuration to a TFTP file server.(See the “Copying the Configuration File to a TFTP Server” section on page 31.)

To remove an I/O controller from a Cisco 7200 series router or Cisco uBR7200 series router, complete the following steps:

Step 1 Power down the router and disconnect the input power cable. (See the “Powering Down the Router and Disconnecting Input Power” section on page 33.)

Step 2 Attach an ESD-preventive wrist strap between you and an unfinished chassis surface.

Step 3 Disconnect the cables from the I/O controller console, auxiliary, and Fast Ethernet(if present) ports. (For a Cisco 7200 series router, see Figure 21. For a Cisco uBR7200 series router, see Figure 22.)

Figure 21 Cisco 7200 Series Input/Output Controller and Ports

1 Port adapter 5 MII and RJ-45 Fast Ethernet ports

2 Port adapter latch 6 Auxiliary port

3 I/O controller 7 Console port

4 PC Card slots

2ETHERNET-10BFL

EN

RX

0 1 2 3 4TX RX TX RX TX RX TX RX TX

Cisco 7200 SERIES XVR

0

4

1

3

EN

0 71 2 3 4 5 6SERIAL-EIA/TIA-232

MII

EN R

J45

EN R

J45

LINK

1O P

WR

OK

RJ-45

CPU RESET FAST ETHERNET INPUT/OUTPUT CONTROLLER

ENABLED

PCMCIA

EJECT

SLOT 0

SLOT 1

FE MII

ETHERNET 10BT

ENABLE

D

0 2

1 3

LINK

0 1 2 3

ENABLE

D

MII

LIN

K

RJ4

5

FAST ETHERNET

0

1588

9

1

2

3

64 75

39Input/Output Controller Replacement Instructions

OL-4447-02

Page 40: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

Figure 22 Cisco uBR7200 Series Input/Output Controller Ports, Handle, and Captive Installation

Screws (Cisco uBR7246 Shown)

Step 4 Remove the Flash Disk or Flash memory cards (if present) from the I/O controller PC Card slots. (See the “Installing and Removing a Flash Memory Card or Flash Disk” section on page 78.)

Step 5 Using a number 2 Phillips or a 3/16-inch flat-blade screwdriver, loosen the two captive installation screws on the faceplate of the I/O controller. (For a Cisco 7200 series router, see Figure 21. For a Cisco uBR7200 series router, see Figure 22.)

Note If you have difficulty installing a processing engine or I/O controller in the lowest slot of a Cisco 7200 VXR router that is rack-mounted, remove the port adapters, processing engine and I/O controller from the chassis and reinstall them. Install the processing engine and I/O controller in the lowest slots first, then populate the slots above them, in a bottom-to-top order.

Step 6 Grasp the I/O controller handle and carefully pull the I/O controller from its chassis slot.

Caution Handle the I/O controller by the carrier edges and handle only; never touch the printed circuit board components or connector pins. (See Figure 14.)

Step 7 Place the I/O controller on an antistatic surface, or in a static shielding bag, with its components facing upward. If you are returning the I/O controller to the factory, immediately place it in a static shielding bag.

This completes the procedure for removing an installed I/O controller.

1 PC Card slots 5 Console port

2 Fast Ethernet port (MII port and RJ-45 port) 6 Captive installation screw

3 Handle 7 I/O controller

4 Auxiliary port93

814

1 2 3 4 5 6

7

40Input/Output Controller Replacement Instructions

OL-4447-02

Page 41: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

Replacing an Input/Output ControllerTo install a new I/O controller in the router, complete the following steps:

Step 1 Ensure that the router is powered down and its input power cable is disconnected from the router and the power source. (See the “Powering Down the Router and Disconnecting Input Power” section on page 33.)

Step 2 Attach an ESD-preventive wrist strap between you and an unfinished chassis surface.

Step 3 Remove the I/O controller from its static shielding bag.

Step 4 Using both hands, grasp the I/O controller by its metal carrier edges and orient the I/O controller so that its printed circuit board components are upward. (See Figure 14.)

Caution Handle the I/O controller by the carrier edges and handle only; never touch the printed circuit board components or connector pins.

Step 5 Align the left and the right edge of the I/O controller printed circuit board between the I/O controller slot guides. (For a Cisco 7200 series router, see Figure 23. For a Cisco uBR7200 series router, see Figure 24.)

Note If you have difficulty installing a processing engine or I/O controller in the lowest slot of a Cisco 7200 VXR router that is rack-mounted, remove the port adapters, processing engine and I/O controller from the chassis and reinstall them. Install the processing engine and I/O controller in the lowest slots first, then populate the slots above them, in a bottom-to-top order.

Figure 23 Aligning the I/O Controller Printed Circuit Board Between the Slot Guides in the

Cisco 7200 Series

1 Printed circuit board 3 I/O controller

2 Metal carrier 4 Slot guides

9381

0

ETHERNET 10BT

ENABLE

D

0 2

1 3

LINK

0 1 2 3

FAST SERIAL

ENTD TC RD RC LB CD TD TC RD RC LB CD TD TC RD RC LB CD TD TC RD RC LB CD

ENABLE

D

MII

LIN

K

RJ4

5

FAST ETHERNET

0

TOKEN RING

0 1 2 3

0

2

4

6

1

3

5

ETHERNET-10BFL

EN

RX

0 1 2 3 4TX RX TX RX TX RX TX RX TX

MII

EN R

J45

EN R

J45

LINK

1O P

WR

OK

RJ-45

CPU RESET

FAST ETHERNET INPUT/OUTPUT CONTROLLER

ENABLED

PCMCIA

EJECT

SLOT 0

SLOT 1

FE MII

2 3

1

4

41Input/Output Controller Replacement Instructions

OL-4447-02

Page 42: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

Figure 24 Aligning the I/O Controller Printed Circuit Board Between the Slot Guides in the

Cisco uBR7200 Series (Cisco uBR7246 Shown)

Caution Do not align the I/O controller metal carrier between the slot guides. Doing so damages components on the I/O controller printed circuit board as you slide the I/O controller into its chassis slot.

Step 6 Gently slide the I/O controller all the way into its chassis slot until you feel the connectors make contact with the router midplane.

Step 7 Seat the I/O controller in the router midplane by tightening its captive installation screws with a number 2 Phillips or a 3/16-inch flat-blade screwdriver.

Step 8 Connect the cables to the I/O controller console, auxiliary, and Fast Ethernet (if present) ports. (For a Cisco 7200 series router, see Figure 21. For a Cisco uBR7200 series router, see Figure 22.) (See the “Connection Equipment and Port Signaling” section on page 64.)

Step 9 Replace the Flash Disk or Flash memory cards (if present) in the PC Card slots. (See the “Installing and Removing a Flash Memory Card or Flash Disk” section on page 78.)

This completes the procedure for replacing the I/O controller in a Cisco 7200 series router or Cisco uBR7200 series router.

Reconnecting Input Power and Powering Up the RouterThe following procedures explain how to reconnect input power to a Cisco 7200 series router or Cisco uBR7200 series router, power up the router, and verify a successful system boot.

1 Metal carrier 3 Printed circuit board

2 Slot guides 4 I/o controller

6642

1

2

4

3

1

42Input/Output Controller Replacement Instructions

OL-4447-02

Page 43: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

Warning Read the installation instructions before you connect the system to its power source. Statement 10

To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

Reconnecting AC-Input Power

To reconnect AC-input power to a Cisco 7200 series router or Cisco uBR7200 series router, complete the following steps:

Step 1 At the rear of the router, check that the power switch on the power supply is in the OFF (O) position.

Step 2 Slide the cable-retention clip up (Cisco 7200 series) or to the left (Cisco uBR7200 series), away from the AC receptacle, and plug in the power cable. (For a Cisco 7200 series router, see Figure 25. For a Cisco uBR7200 series router, see Figure 26.)

Step 3 Secure the cable in the power supply AC receptacle by sliding the cable-retention clip down (Cisco 7200 series) or to the right (Cisco uBR7200 series), until it snaps around the connector. The cable-retention clip provides strain relief for the AC power cable.

Figure 25 Connecting AC-Input Power to a Cisco 7200 Series Router

1 Power switch 4 Power cable-retention clip

2 Power cord 5 Handle with hole for cable tie

3 PWR OK LED

8439

8

1

2 3 54

43Input/Output Controller Replacement Instructions

OL-4447-02

Page 44: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

Figure 26 Connecting AC-Input Power to a Cisco uBR7200 Series Universal Broadband Router

Step 4 Plug the AC power supply cable into the AC power source.

Note For Cisco 7200 series routers, each AC-input power supply operating at 120 VAC requires a minimum of 5A service. For Cisco uBR7200 series routers, each AC-input power supply operating at 120 VAC requires a minimum of 7A service. We recommend powering Cisco 7200 series routers and Cisco uBR7200 series routers from a 120 VAC, 15A receptacle United States (240 VAC, 10A international) at the power source.

Step 5 Repeat Step 1 through Step 4 if a second power supply is installed.

This completes the steps for reconnecting AC-input power to a Cisco 7200 series router or Cisco uBR7200 series router. Proceed to the “Powering Up the Router” section on page 49.

1 Cable-retention clip 4 AC power cable

2 Power receptacle 5 Power switch

3 Captive installation screw 6 Handle

6642

2

3

4

25

1

6

44Input/Output Controller Replacement Instructions

OL-4447-02

Page 45: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

Reconnecting DC-Input Power

Note The color-coding of the DC-input power supply leads depends on the color-coding of the DC power source at your site. Typically, green or green/yellow is used for ground, black is used for +V (return), and red or white is used for –V. Make certain the lead color-coding you choose for the DC-input power supply matches the lead color-coding used at the DC power source.

Warning Before completing any of the following steps, and to prevent short-circuit or shock hazards, ensure that power is removed from the DC circuit. To ensure that all power is off, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the off position, and tape the switch handle of the circuit breaker in the off position. Statement 322

To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

Warning When installing the unit, the ground connection must always be made first and disconnected last. Statement 42

To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

To reconnect DC-input power to a Cisco 7200 series router or Cisco uBR7200 series router, complete the following steps:

Step 1 Ensure that the –V and +V leads are disconnected from the power source.

Step 2 At the rear of the router, check that the power switch on the power supply is in the OFF (O) position. (For a Cisco 7200 series router, see Figure 27. For a Cisco uBR7200 series router, see Figure 28.)

45Input/Output Controller Replacement Instructions

OL-4447-02

Page 46: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

Figure 27 Connecting DC-Input Power to a Cisco 7200 Series Router

Figure 28 Connecting DC-Input Power to a Cisco uBR7200 Series Universal Broadband Router

1 Power switch 3 Cable tie

2 Ground lead service loop 4 DC power leads

6643

2

2

1

3

4

1 Power switch 6 –V lead

2 Power receptacle 7 M4 studs

6640

7

3

8

1 2

9

7

5 6

4

46Input/Output Controller Replacement Instructions

OL-4447-02

Page 47: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

Step 3 If necessary, use a wire stripper to strip approximately 0.55 inch (14 mm) from the –V, +V, and ground leads. (See Figure 29.)

Figure 29 Stripping the DC-Input Leads

Note The ground lead for a Cisco uBR7200 series DC-input power supply consists of a two-hole grounding lug that connects to an M5 grounding receptacle; you do not need to strip this ground lead.

Step 4 Attach the ground lead:

• For a Cisco 7200 series router, insert the stripped end of the ground lead all the way into the ground lead receptacle on the DC-input power supply, and tighten the receptacle screw using a 3/16-inch flat-blade screwdriver. (See Figure 27.)

• For a Cisco uBR7200 series router, connect the two-hole grounding lug on the grounding lead to the M5 grounding receptacles using the M5 nuts. Tighten the nuts using the 8-mm wrench or nut driver (or adjustable wrench). (See Figure 28.)

Step 5 Insert the stripped end of the +V lead all the way into the +V lead receptacle and tighten the receptacle screw using the same 3/16-inch flat-blade screwdriver. Repeat Step 5 for the –V lead.

Note Make sure that the entire stripped end of each lead is inserted all the way into its receptacle. If any exposed wire at the stripped end of a lead is visible after you insert the lead into its receptacle, remove the lead from the receptacle, use the wire stripper to cut the stripped end of the lead, and repeat Step 3 through Step 5.

Step 6 After tightening the receptacle screw or nuts for the ground, +V, and –V DC-input leads, secure the leads to the power supply faceplate:

• For a Cisco 7200 series router, use the cable tie you saved earlier in this procedure to secure the three leads.

• For a Cisco uBR7200 series router, run the +V and –V leads between the two strain-relief studs on the power supply faceplate. (See Figure 28.)

3 Captive installation screw 8 +V lead

4 M5 grounding receptacles 9 Handle

5 M5 grounding lug

1 0.55 in. (14 mm)

5701

9

1

47Input/Output Controller Replacement Instructions

OL-4447-02

Page 48: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

Note For Cisco 7200 series routers, when securing the ground, +V, and –V DC-input leads to the power supply faceplate, leave a small service loop in the ground lead to ensure that it is the last lead to disconnect from the power supply if a great deal of strain is placed on all three leads. (See Figure 27.)

A service loop is not required in the lead attached to the grounding lug on Cisco uBR7200 series routers, because this lead is separate from the +V and –V leads and is secured by two M5 nuts to the M5 receptacles.

Step 7 For a Cisco uBR7200 series router, replace the strain-relief cover over the +V and –V leads and secure the cover to the strain-relief studs using the two M4 nuts with the 7-mm wrench or nut driver (or adjustable wrench). (See Figure 30.)

Figure 30 Replacing the Strain-Relief Cover on a Cisco uBR7200 Series DC-Input Power Supply

Step 8 Connect the ground, +V, and –V leads to the power source.

1 Power switch 6 –V lead

2 Power 7 +V lead

3 Captive installation screw 8 Strain-relief cover

4 M5 grounding receptacles 9 M4 nuts

5 M5 grounding lug

3

5

6 7

8

1 2

9

466

409

48Input/Output Controller Replacement Instructions

OL-4447-02

Page 49: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

Note For Cisco 7200 series routers, each DC-input power supply operating at – 48 VDC in North America requires a minimum of 13A service. Each DC-input power supply operating at –60 VDC in the European Union requires a minimum of 8A service.

For Cisco uBR7200 series routers, each DC-input power supply rating is 14A, 700 volt amperes (VA).

Warning This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that a listed and certified fuse or circuit breaker, 35A minimum 60 VDC, is used on all current-carrying conductors. Statement 13

To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.

Step 9 Repeat Step 1 through Step 8 if a second power supply is installed.

This completes the steps for reconnecting DC-input power to a Cisco 7200 series router or Cisco uBR7200 series router.

Powering Up the Router

To power up a Cisco 7200 series router or Cisco uBR7200 series router that has an installed AC-input or DC-input power supply, complete the following steps:

Step 1 Check for the following:

• Each port adapter is inserted in its slot, and its respective port adapter lever or retention clip is in the locked position.

• The network processing engine or network services engine and the I/O controller are inserted in their respective slots, and their captive installation screws are tightened.

• All network interface cables are connected to the port adapters.

• Each cable modem card is inserted in its slot, and its respective captive installation screws are tightened (Cisco uBR7200 series only).

• If present, a Flash memory card is properly installed in its PC card slot.

• Each AC-input power cable is connected and secured with the cable-retention clip (AC-input power supplies only).

• For a Cisco 7200 series router, each DC lead is connected and secured to the power supply faceplate with a cable tie; for a Cisco uBR7200 series router, each DC lead is connected with M5 nuts for the grounding receptacle and the strain-relief cover over the +V and –V leads (DC-input power supplies only).

• Each DC lead is connected and secured to the power source (DC-input power supplies only).

• Ensure that the tape (that you applied earlier) is removed from the circuit breaker switch handle, and power is restored by moving the circuit breaker handle to the ON position (DC-input power supplies only).

49Input/Output Controller Replacement Instructions

OL-4447-02

Page 50: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

• The console terminal is turned on.

Caution When the power switch on a Cisco uBR7200 series power supply is turned to the OFF (O) position, the power supply enters a reset cycle for 90 seconds. Wait at least 90 seconds before turning the power switch back to the ON (|) position. If you do not wait the full 90 seconds, the power supply does not restart.

Step 2 At the rear of the router, place the power switch on the power supply in the ON (|) position. Repeat this step if a second power supply is installed in the router. The green OK LED on the power supply comes on.

Step 3 Listen for the fans; you should immediately hear them operating.

Step 4 During the boot process, observe the system LEDs. The LEDs on most of the port adapters and Cisco uBR7200 series cable modem cards go on and off in irregular sequence. Some may come on, go out, and come on again for a short time. On the I/O controller, the IO POWER OK LED comes on immediately.

Step 5 Observe the initialization process. When the system boot is complete (a few seconds), the network processing engine or network services engine begins to initialize the port adapters, Cisco uBR7200 series cable modem cards, and the I/O controller. During this initialization, the LEDs on each port adapter behave differently (most flash on and off). The enabled LED on each port adapter and Cisco uBR7200 series cable modem card comes on when initialization is completed, and the console screen displays a script and system banner similar to the following display:

Cisco Internetwork Operating System Software IOS (tm) 7200 Software (C7200-J-M), Version 11.1(9) [kpfjrgiu 100]Copyright (c) 1986-1996 by cisco Systems, Inc.Compiled Sun 21-Apr-96 04:10 by

This completes the procedures for connecting input power and powering up the router.

Downloading the Saved Configuration from the TFTP ServerAfter you install a new I/O controller in the router and verify a successful router boot, you must retrieve the router configuration from the TFTP server and copy it to NVRAM. Use the copy tftp running-config command to copy the saved configuration from the TFTP file server. The system prompts you for a host name and address, the name of the configuration file stored on the host, and confirmation to reboot using the remote file.

If you replaced an I/O controller without the Fast Ethernet port with an I/O controller with the Fast Ethernet port, you will most likely want to configure the new interface after retrieving the router configuration from the TFTP server and copying it to NVRAM.

Before retrieving the router configuration file from the TFTP file server, check the following:

• A console terminal is connected to the console port on the I/O controller, or a Telnet session is established to the router.

• The router is connected to a network supporting a file server (remote host).

• The remote host supports the TFTP application.

• You have the name or address of the remote host.

Before configuring the new interface on the I/O controller, be prepared with the following information:

50Input/Output Controller Replacement Instructions

OL-4447-02

Page 51: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Removing and Replacing the Input/Output Controller

• Protocols and encapsulations you plan to use on the new interface

• Protocol-specific information, such as IP addresses, if you will configure the interface for IP routing

For complete descriptions of interface commands and the configuration options available for Cisco 7200 series and Cisco uBR7200 series-related interfaces, refer to the documentation resources listed in the “Related Documentation” section on page 2.

To retrieve the saved router configuration from the remote host, complete the following steps:

Step 1 Make sure that you are at the privileged level of the EXEC command interpreter (check the system prompt for a pound sign [#]). If the system prompt does not have a pound sign (#), enter enable, press Return, and then enter your password.

Note Until you retrieve the saved configuration, the router runs from the default configuration in NVRAM. Therefore, any passwords that were previously configured on the system are not valid until you retrieve the configuration.

Step 2 Use the ping command to check the connection between the router and the remote host (the remote file server to which you copied the configuration file).

Step 3 At the system prompt, enter the copy tftp running-config command and press Return to enter configuration mode. Specify that you will configure the system from a network device (instead of from the console terminal, which is the default).

Router# copy tftp running-config

Step 4 The system prompts you to select a host or network configuration file. The default is host; press Return to accept the default.

Host or network configuration file [host]?

Step 5 The system prompts you for the IP address of the host. Enter the IP address or name of the remote host.

IP address of remote host [255.255.255.255]? 10.1.1.1

Step 6 The system prompts you for the name of the configuration file. When the system copies the file to the server, the default is to use the name of the router with the suffix -confg (router-confg in the following example). If you specified a different filename when you copied the configuration, enter that filename; otherwise, press Return to accept the default.

Name of configuration file [router-confg]?

Step 7 Before the system reboots with the new configuration, it displays the instructions you entered for confirmation. If the instructions are not correct, enter n (no), and then press Return to cancel the process. To accept the instructions, press Return, or y, and then Return.

Configure using router-confg from 10.1.1.1? [confirm]Booting router-confg from 10.1.1.1: ! ! [OK - 874/16000 bytes]

While the router retrieves and boots from the configuration on the remote host, the console display indicates whether or not the operation was successful. A series of exclamation points (!!!! ) and [OK] (as shown in the preceding example) indicate that the operation was successful. A series of periods ( . . ). and [timed out] or [failed] indicate a failure (which would probably be due to a network fault or an incorrect server name, address, or filename). The following is an example of a failed attempt to boot from a remote server:

Booting Router-confg ..... [timed out]

51Input/Output Controller Replacement Instructions

OL-4447-02

Page 52: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Configuring the I/O Controller Interfaces

• If the display indicates that the process was successful, proceed to the next step.

• If the display indicates that the process failed, verify the name or address of the remote server and the filename, and repeat the preceding steps. If you are unable to retrieve the configuration, contact your network administrator or see the “Obtaining Documentation and Submitting a Service Request” section on page 82 for instructions on contacting Cisco technical assistance.

Step 8 Enter the show running-config command to display the currently running configuration on the terminal. Review the display and ensure that the configuration information is complete and correct. If it is not, verify the filename and repeat the preceding steps to retrieve the correct file, or use the configure command to add or modify the existing configuration. (Refer to the appropriate software documentation for descriptions of the configuration options available for the system and individual interfaces and specific configuration instructions.)

Step 9 When you have verified that the currently running configuration is correct, enter the copy running-config startup-config command to save the retrieved configuration in NVRAM. Otherwise, the new configuration will be lost when you restart the system.

This completes the procedure for downloading the saved router configuration from the remote host. Proceed to the following section, “Configuring the I/O Controller Interfaces,” if you installed an I/O controller with an Ethernet, Fast Ethernet, or Gigabit Ethernet interface. If you installed an I/O controller without any Ethernet interfaces, this completes the procedure for replacing the I/O controller in a Cisco 7200 series router or Cisco uBR7200 series router. Proceed to the “Connection Equipment and Port Signaling” section on page 64 for additional information you might need when replacing an I/O controller in a Cisco 7200 series router or Cisco uBR7200 series router.

Configuring the I/O Controller InterfacesThis section describes the configuration commands you need to configure the different interfaces on your I/O controller. Interface attributes that can be configured on your I/O controller include media type, transmission mode, and speed. Table 12 lists the models, their interface types, default settings, and the commands to change the defaults.

Table 12 I/O Controller Interface Configuration Commands and Defaults

Model Interface Default Value Commands

C7200-I/O None — —

C7200-I/O-FE Fast Ethernet (RJ-45 or MII) RJ-45 port (100BASE-T)

media-type mii media-type 100baset

Half-duplex duplex {full | half} no duplex1

C7200-I/O-FE-MII Fast Ethernet (MII only) Half-duplex duplex {full | half} no duplex1

C7200-I/O-GE+E Ethernet (Ethernet is not configurable in Cisco IOS Release 12.0 S.)

Autonegotiation duplex {full | half | auto} no duplex1

Gigabit Ethernet Autonegotiation negotiation auto2 no negotiation auto3

52Input/Output Controller Replacement Instructions

OL-4447-02

Page 53: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Configuring the I/O Controller Interfaces

Note The Gigabit Ethernet (GE) port on the C7200-I/O-GE+E does not support the duplex command. The GE port operates at full duplex and cannot be configured for half-duplex mode. The Ethernet port on the same card supports the duplex command but not the speed command. Speed for the Ethernet port is fixed at 10 Mbps.

If you are running a Cisco IOS software release earlier than Cisco IOS Release 12.0 T or Cisco IOS Release 12.0 XE or Cisco IOS Release 12.0 S, you must use the full-duplex command instead of the duplex {full | half | auto} command to change transmission mode. Use the no full-duplex command to return to half-duplex mode. Autoduplex selection is not available in these releases.

Configuring Interface Media TypeFor the I/O controller with both an MII and an RJ-45 Fast Ethernet port (C7200-I/O-FE), you need to configure the media type for the port you want to use. The RJ-45 port is the default media type for this I/O controller. Use the media-type command to change the I/O controller media type and the show interfaces command to verify the change.

The following example configures the MII port as the media type for the C7200-I/O-FE:

Router# configure terminalEnter configuration commands, one per line. End with CNTL/Z.Router(config)# interface fastethernet 0/0Router(config-if)# media-type miiRouter(config-if)# no shutdownRouter(config-if)# exitRouter(config)#%LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/0, changedstate to up%LINK-3-UPDOWN: Interface FastEthernet0/0, changed state to up

Router# show interfaces fastethernet 0/0FastEthernet0/0 is administratively up, line protocol is up

(display text omitted)

Encapsulation ARPA, loopback not set, keepalive not set, hdx, MII

(display text omitted)

C7200-I/O-2FE/E 2 independent autosensing4 Ethernet/Fast Ethernet (Ethernet is not configurable in Cisco IOS Release 12.0 S.)

Autonegotiation duplex {full | half | auto} no duplex1

Autonegotiation speed {10 | 100 | auto}

1. The no duplex command returns the transmission mode to the default value set for that port.

2. Enables full-duplex operation, 1000-Mbps speed, and flow control.

3. The no negotiation auto command turns the interface to the force link mode. The force link mode turns off the flow control. Transmission mode and speed remains set at full duplex and 1000 Mbps, respectively.

4. To fully enable autonegotiation on the Ethernet/Fast Ethernet interfaces, use the defaults: duplex auto and speed auto (Fast Ethernet only). For autonegotiation to work correctly, the interface at the other end of the link (link partner) must also be able to support autonegotiation. If autonegotiation is not supported, the Ethernet/FastEthernet interface defaults to half-duplex operation and you may have to configure the duplex manually.

Table 12 I/O Controller Interface Configuration Commands and Defaults (continued)

Model Interface Default Value Commands

53Input/Output Controller Replacement Instructions

OL-4447-02

Page 54: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Configuring the I/O Controller Interfaces

Use the media-type 100baset command to return the media type to the RJ-45 port.

Note In the case of the I/O controller with one Gigabit Ethernet port and one Ethernet port (C7200-I/O-GE+E), both ports are fully independent; therefore, you do not need to configure the media type. The interface addresses for this I/O controller are gigabitethernet 0/0 and ethernet 0/0, respectively.

Configuring Interface Transmission ModeThe default transmission mode for the 10BASET/100BASETX autosensing Ethernet/Fast Ethernet interfaces on the C7200-I/O-2FE/E model is auto.

The default transmission mode for the Fast Ethernet port on the C7200-I/O-FE and C7200-I/O-FE-MII I/O controller models is half-duplex. The auto command option is not available for these models.

Use the duplex {full | half | auto} command to change the Fast Ethernet port transmission mode, and use the show interfaces command to verify the change as follows:

Router# configure terminal

Enter configuration commands, one per line. End with CNTL/Z.

Router(config)# interface fastethernet 0/0Router(config-if)# duplex fullRouter(config-if)# no shutdownRouter(config-if)# exitRouter(config)#

%LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/0, changed state to up%LINK-3-UPDOWN: Interface FastEthernet0/0, changed state to up

Router# show interfaces fastethernet 0/0FastEthernet0/0 is administratively up, line protocol is up

(display text omitted)

Encapsulation ARPA, loopback not set, keepalive not setKeepalive set (10 sec) Full-duplex, l00MB, 100BaseTX

Use the no duplex command to return the Fast Ethernet port on the I/O controller to its default transmission mode. (For default listings for each model, see Table 12.)

Note If you are running a Cisco IOS software release earlier than Cisco IOS Release 12.0 T, Cisco IOS Release 12.0 S, or Cisco IOS Release 12.0 XE, you must use the full-duplex command instead of the duplex {full | half | auto} command to change transmission mode. Use the no full-duplex command to return to half-duplex mode.

Note In a Cisco 7206 or Cisco 7206VXR router shelf, the interface specified in the above examples would include a shelf number. For example, the command interface fastethernet 5/0/0 would specify the Fast Ethernet interface on the I/O controller (slot 0) in router shelf 5. For information about the Cisco AS5800 universal access server router shelf, refer to the Cisco AS5800 universal access server documentation listed in the “Related Documentation” section on page 2.

54Input/Output Controller Replacement Instructions

OL-4447-02

Page 55: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Configuring the I/O Controller Interfaces

Configuring Interface SpeedThe I/O controller C7200-I/O-2FE/E has two 10BASET/100BASETX autosensing Ethernet/Fast Ethernet interfaces equipped with RJ-45 ports. To configure these interfaces, use the duplex command and the speed command. The default transmission mode is auto and the default interface speed is auto. To fully enable autonegotiation on the Ethernet/Fast Ethernet interfaces, use the duplex auto command and the speed auto command. To change the default settings, use the following command options for Cisco IOS Release 12.1 E and Cisco IOS Release 12.1 T only:

duplex {full | half | auto}no duplex

speed {10 | 100 | auto}no speed

Performing a Basic ConfigurationThe following procedure explains a basic configuration for an Ethernet, Fast Ethernet, or Gigabit Ethernet interface on the I/O controller. In the following procedure, press the Return key after each step unless otherwise noted. At any time, you can exit the privileged level and return to the user level by entering disable at the prompt as follows:

Router# disable

Router>

Note In Cisco 7200 series routers and Cisco uBR7200 series routers, you identify interfaces by port adapter slot number and interface port number (slot/port). Port adapter slot 0 in Cisco 7200 series routers and Cisco uBR7200 series routers is always reserved for the ports on the I/O controller. Therefore, the address of any port on the I/O controller (if present) in Cisco 7200 series routers or Cisco uBR7200 series routers is always 0/x, where x is the interface port number.

In the Cisco 7206 or Cisco 7206VXR router shelf, you identify interfaces by shelf number, port adapter slot number, and interface port number (shelf/slot/port). The shelf number is a number assigned to the router shelf during the initial configuration of the Cisco AS5800 universal access server. Port adapter slot 0 in the router shelf is also reserved for ports on the I/O controller. Therefore, the address of the port on the I/O controller (if present) in a router shelf is y/0/x, where y is the shelf number and x is the interface port number. For information about the Cisco 7206 and Cisco 7206VXR as router shelves in a Cisco AS5800 universal access server, refer to the Cisco AS5800 universal access server documentation listed in the “Related Documentation” section on page 2.

Step 1 At the privileged-level prompt, enter configuration mode and specify that the console terminal will be the source of the configuration subcommands as follows:

Router# configure terminal

Enter configuration commands, one per line. End with CNTL/Z.Router(config)#

Step 2 Specify the port on the I/O controller interface to configure by entering the interface {ethernet | fastethernet | gigabitethernet} slot/port command. For example,

Router(config)# interface fastethernet 0/0

55Input/Output Controller Replacement Instructions

OL-4447-02

Page 56: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Configuring the I/O Controller Interfaces

Note In a Cisco 7206 or Cisco 7206VXR router shelf, the interface specified in Step 2 would include a shelf number. For example, the command interface fastethernet 5/0/0 would specify the Fast Ethernet interface on the I/O controller (slot 0) in router shelf 5.

Step 3 If IP routing is enabled on the system, assign an IP address and subnet mask to the interface with the ip address subcommand as follows:

Router(config-int)# ip address 10.1.1.10 255.255.255.0

Step 4 If you installed an I/O controller with the Fast Ethernet port that is equipped with an MII port and an RJ-45 port, use the media-type command to specify the I/O controller media type; the default is the RJ-45 port. The following example shows the MII port being configured as the media type:

Router(config-if)# media-type mii

Note Use the media-type 100baset command to return the media type to the RJ-45 port.

Step 5 Use the duplex command to specify transmission mode (see Table 12 for command options and defaults). The following example shows full-duplex mode being configured:

Router(config-if)# duplex full

Step 6 Change the shutdown state to up and return to configuration mode to enable the interface, as follows:

Router(config-if)# no shutdownRouter(config-if)# exitRouter(config)#

%LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/0, changedstate to up%LINK-3-UPDOWN: Interface FastEthernet0/0, changed state to up

Step 7 Press Ctrl-Z (hold down the Control key while you press Z) or enter end to exit configuration mode and return to the EXEC command interpreter prompt as follows:

Router(config)#Ctrl-ZRouter#

Step 8 Write the new configuration to nonvolatile memory as follows:

Router# copy running-config startup-config[OK]Router#

Step 9 Use the show interfaces {ethernet | fastethernet | gigabitethernet} command to verify that the interface and line protocol are in the correct state (up) and that the correct media type (MII or RJ-45) and transmission mode (full, half, or auto) are configured on the interface. The following example shows that the C7200-I/O-FE Fast Ethernet interface and line protocol are up, the media type is RJ-45 (shown below as 100BaseTX), and the transmission mode is full-duplex:

Router# show interfaces fastethernet 0/0FastEthernet0/0 is administratively up, line protocol is up

(display text omitted)

Encapsulation ARPA, loopback not set, keepalive not setKeepalive set (10 sec) Full-duplex, l00MB, 100BaseTX

(display text omitted)

56Input/Output Controller Replacement Instructions

OL-4447-02

Page 57: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Using show Commands to Check the Installation

Note In a Cisco 7206 or Cisco 7206VXR router shelf, the interface specified in this step would include a shelf number.

This completes the procedure for a basic configuration of the I/O controller interfaces.

Using show Commands to Check the InstallationUse show commands to identify the hardware installed in your router, to verify the operation status, to view interface configuration settings, and to troubleshoot your router configuration. The interfaces on your I/O controller are identified by chassis slot number and interface port number (slot/port). The chassis slot number for the I/O controller is always slot 0. Table 13 lists the I/O controller models, their corresponding interfaces, and the interface addressing syntax for each interface.

This remainder of this section provides examples of show commands that pertain to the I/O controller.

Note Slot 0 in Cisco 7200 series routers (including the Cisco 7206 and Cisco 7206VXR as router shelves in a Cisco AS5800 universal access server) and Cisco uBR7200 series routers is always reserved for the Ethernet, Fast Ethernet, or Gigabit Ethernet ports, if present, on the I/O controller.

Table 13 Identifying Interface Addresses

Model Interface Numbers Syntax

C7200-I/O-GE+E Gigabit Ethernet (port GE 0) Chassis slot—always 0

Interface port—0

0/0

Ethernet (port E 0) Chassis slot—always 0

Interface port—0

0/0

C7200-I/O-2FE/E Fast Ethernet/Ethernet (port 0) Chassis slot—always 0

Interface port—0

0/0

Fast Ethernet/Ethernet (port 1) Chassis slot—always 0

Interface port—1

0/1

C7200-I/O-FE1

1. The product number C7200-I/O-FE does not specify MII because both an MII and an RJ-45 port are included.

Fast Ethernet (MII or RJ-45) Chassis slot—always 0

Interface port—0

0/0

C7200-I/O No interface ports — —

C7200-I/O-FE-MII2

2. The I/O controller with the product number C7200-I/O-FE-MII has a single MII Fast Ethernet port only. Although still supported by Cisco Systems, this I/O controller with a single MII port is no longer an orderable product as of April 1998.

Fast Ethernet (MII) Chassis slot—always 0

Interface port—0

0/0

57Input/Output Controller Replacement Instructions

OL-4447-02

Page 58: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Using show Commands to Check the Installation

Note The C7200-I/O-GE+E I/O controller uses independent port numbering for the two different media interfaces on the card. The Gigabit Ethernet port is numbered slot 0, port 0 and the Ethernet port is numbered slot 0, port 0.

Use the show interfaces command to check the status of an interface and to see how it is configured. The following example shows the status and configuration settings for the Gigabit Ethernet interface.

Router# show interfaces gigabitethernet 0/0

GigabitEthernet0/0 is up, line protocol is up Hardware is 82543 (Livengood), address is 00d0.ffb6.4c00 (bia 00d0.ffb6.4c00) Internet address is 11.1.1.3/8 MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec, reliability 255/255, txload 1/255, rxload 1/255 Encapsulation ARPA, loopback not set Keepalive set (10 sec) Full-duplex mode, link type is autonegotiation, media type is SX output flow-control is on, input flow-control is on ARP type:ARPA, ARP Timeout 04:00:00 Last input 00:00:04, output 00:00:03, output hang never Last clearing of "show interface" counters never Queueing strategy:fifo Output queue 0/40, 0 drops; input queue 0/75, 0 drops 5 minute input rate 0 bits/sec, 0 packets/sec 5 minute output rate 0 bits/sec, 0 packets/sec 2252 packets input, 135120 bytes, 0 no buffer Received 2252 broadcasts, 0 runts, 0 giants, 0 throttles 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored 0 watchdog, 0 multicast, 0 pause input 0 input packets with dribble condition detected 2631 packets output, 268395 bytes, 0 underruns 0 output errors, 0 collisions, 2 interface resets 0 babbles, 0 late collision, 0 deferred 0 lost carrier, 0 no carrier, 0 pause output 0 output buffer failures, 0 output buffers swapped out

Use the show controllers command to display initialization block information, transmit ring, receive ring, and errors for the I/O controllers. The following sample is output for the show controllers gigabitethernet command.

Router# show controllers gigabitethernet 0/0

Interface GigabitEthernet0/0 (idb 0x61677314)Hardware is i82543 A1 network connection mode is AUTO network link is up loopback type is none SERDES is enabled (TBI mode), GBIC is enabled GBIC type is 1000BaseSX i82543 MAC registers: CTRL =0x1ACC0004, STATUS=0x00000FAB, CTRL_X=0x000048E0, IMS =0x00000096 RCTL =0x00428032, RDBAL =0x2000E000, RDBAH =0x00000000, RDLEN =0x00001000 RDH =0x00000009, RDT =0x00000008, RDTR =0x00000000 TCTL =0x000400FA, TDBAL =0x20010000, TDBAH =0x00000000, TDLEN =0x00001000 TDH =0x0000000B, TDT =0x0000000B, TIPG =0x00600806 ETT =0x00000000, TXDMAC=0x00000001 TXCW =0xC00001A0, RXCW =0xDC0041A0, FCRTH =0x0000AFF0, FCRTL =0x80001200 FCAH =0x00000100, FCAL =0x00C28001, FCT =0x00008808, FCTTV =0x00000080 RDFH =0x00000195, RDFT =0x00000195, RDFPC =0x00000000 TDFH =0x00001A1C, TDFT =0x00001A1C, TDFPC =0x00000000 RX is normal, enabled TX is normal, enabled

58Input/Output Controller Replacement Instructions

OL-4447-02

Page 59: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Using show Commands to Check the Installation

Device status = full-duplex, link up Auto-neg - done Auto-neg - bit sync OK, Received idle stream, invalid symbol, idle chars Auto-neg - Partner Ability is Pause Capable, Asymmetric FC, FD GBIC registers: Register 0x00: 01 00 01 00 00 00 01 00 Register 0x08: 00 00 00 00 0D 00 00 00 Register 0x10: 32 1E 00 00 4D 65 74 68 Register 0x18: 6F 64 65 20 45 6C 65 63 Register 0x20: 2E 20 20 20 00 00 00 00 Register 0x28: 4D 47 42 43 2D 32 30 2D Register 0x30: 34 2D 31 2D 53 20 20 20 Register 0x38: 31 30 30 30 00 00 00 55 Register 0x40: 00 0A 00 00 41 41 46 59 Register 0x48: 43 35 39 20 20 20 20 20 Register 0x50: 20 20 20 20 39 39 30 37 Register 0x58: 32 36 20 20 00 00 00 7D PartNumber:MGBC-20-4-1-S PartRev:G SerialNo:AAFYC59 Options: 0 Length(9um/50um/62.5um):000/500/300 Date Code:990726 Gigabit Ethernet Codes: 1 PCI configuration registers: bus_no=0, device_no=8 DeviceID=0x1001, VendorID=0x8086, Command=0x0156, Status=0x0230 Class=0x02/0x00/0x00, Revision=0x01, LatencyTimer=0xFC, CacheLineSize=0x20 BaseAddr0=0x48100000, BaseAddr1=0x00000000, MaxLat=0x00, MinGnt=0xFF SubsysDeviceID=0x1001, SubsysVendorID=0x8086 Cap_Ptr=0x000000DC Retry/TRDY Timeout=0x00000000 PMC=0x00220001 PMCSR=0x00000000 i82543 Internal Driver Information: lc_ip_turbo_fs=0x6040C2C0, ip_routecache=0x1(dfs=0/mdfs=0) i82543_ds=0x61678F60, registers=0x3C100000 rx cache size=1000, rx cache end=744, rx_nobuffer=0 max_mtu=1524 ring sizes:RX=256, TX=256 rxring=0x2000E000, shadow=0x616792C0, head=9, rx_buf_size=512 txring=0x20010000, shadow=0x616796EC, head=11, tail=11 chip_state=2, pci_rev=1 tx_count=0, tx_limited=0 rx_overrun=0, rx_seq=0, rx_no_enp=0, rx_discard=0 throttled=0, enabled=0, disabled=0, fake_disabled=0 reset=9(init=1, check=0, restart=3, pci=0), auto_restart=9 link_reset=0, tx_carrier_loss=0, fatal_tx_err=0 isl_err=0, wait_for_last_tdt=0 HW addr filter:0x61679F18, ISL disabled, Promiscuous mode multicast Entry= 0: Addr=0000.CACA.BEBE

(display text omitted)

Use the show diag 0 command to identify the I/O controller that is installed in your Cisco 7200 series router or Cisco uBR7200 series router.

Note Because slot 0 in the Cisco 7200 series routers and Cisco uBR7200 series routers is reserved for the I/O controller ports, if you are using an I/O controller without a Fast Ethernet port (C7200-I/O), the system software will not display output for the show diag 0 command.

59Input/Output Controller Replacement Instructions

OL-4447-02

Page 60: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Using show Commands to Check the Installation

Note If you have the C7200-I/O-FE or C7200-I/O-FE-MII I/O controller installed in your Cisco 7202 router, the show diag 0 command output indicates that the Fast Ethernet port is disabled.

The following example of the show diag 0 command shows an installed C7200-I/O-FE that is equipped with an MII port and an RJ-45 port:

Router> show diag 0Slot 0: Fast-ethernet on C7200 I/O with MII or RJ45 port adapter, 1 port Port adapter is analyzed Port adapter insertion time 00:10:42 ago Hardware revision 2.0 Board revision A0 Serial number 3511336 Part number 73-1537-03 Test history 0x0 RMA number 00-00-00 EEPROM format version 1 EEPROM contents (hex): 0x20: 01 14 02 00 00 35 94 28 49 06 01 03 00 00 00 00 0x30: 50 0000 00 FF FF FF FF FF FF FF FF FF FF FF FF

The following example of the show diag 0 command is from a Cisco 7202 that has an installed I/O controller with the Fast Ethernet port. The following text in the command output indicates that the Fast Ethernet port on the I/O controller is disabled:

Port adapter disabled

Router> show diag 0Slot 0: Fast-ethernet on C7200 I/O with MII or RJ45 port adapter, 1 port Port adapter disabled Port adapter insertion time 00:10:42 ago Hardware revision 2.0 Board revision A0 Serial number 3511336 Part number 73-1537-03 Test history 0x0 RMA number 00-00-00 EEPROM format version 1 EEPROM contents (hex): 0x20: 01 14 02 00 00 35 94 28 49 06 01 03 00 00 00 00 0x30: 50 0000 00 FF FF FF FF FF FF FF FF FF FF FF FF

Troubleshooting Using the show interfaces fastethernet CommandIntel Corporation has changed the specifications for its Peripheral Component Interconnect (PCI) bus with a Fast Ethernet hardware interface. These changes have been incorporated into certain Cisco hardware products. For most users, this change is transparent. However, an anomaly has been identified when this updated Cisco hardware is used in conjunction with certain releases of Cisco IOS software. This section explains the anomaly and how to work around it.

Anomaly Details

When you use the Cisco IOS software show interfaces fastethernet command, output similar to the following is normally displayed:

Router# show interfaces fastethernet [slot/port]

FastEthernet0/0 is up, line protocol is up Hardware is DEC21140, address is 00e0.f74f.dc00 (bia 00e0.f74f.dc00)Internet address is 192.168.255.1

60Input/Output Controller Replacement Instructions

OL-4447-02

Page 61: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Using show Commands to Check the Installation

MTU 1500 bytes, BW 100000 Kbit, DLY 100 usec, rely 255/255, load 1/255Encapsulation ARPA, loopback not setKeepalive set (10 sec)Half-duplex, 100Mb/s, MIIARP type: ARPA, ARP Timeout 04:00:00Last input never, output 00:00:06, output hang neverLast clearing of "show interface" counters neverQueueing strategy: fifoOutput queue 0/40, 0 drops; input queue 0/75, 0 drops5 minute input rate 0 bits/sec, 0 packets/sec5 minute output rate 1000 bits/sec, 0 packets/sec0 packets input, 0 bytesReceived 0 broadcasts, 0 runts, 0 giants, 0 throttles0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored0 watchdog, 0 multicast0 input packets with dribble condition detected51 packets output, 11872 bytes, 0 underruns0 output errors, 0 collisions, 0 interface resets0 babbles, 0 late collision, 0 deferred0 lost carrier, 0 no carrier0 output buffer failures, 0 output buffers swapped out

When you enter this command using Cisco IOS software Release 11.1(10) or earlier, or Release 11.2(4) or earlier with updated Cisco hardware, the “overrun” field (shown in bold in the output above) is always zero.

If you use this command because you are troubleshooting potential network problems, you may be expecting to see a number in the overrun field.

Anomaly Workaround

To work around this problem, enter the following Cisco IOS software command to obtain an overrun value:

Router# show controllers fastethernet FE-slot number/0

The following output is normally displayed:

Hardware is DEC21140dec21140_ds=0x603531A0, registers=0x4D800000, ib=0x300612C0rx ring entries=64, tx ring entries=128rxring=0x300613C0, rxr shadow=0x603532C0, rx_head=5, rx_tail=0txring=0x30061800, txr shadow=0x60353400, tx_head=33, tx_tail=33, tx_count=0PHY link upFar End Fault Indication (For FX Interface): OFFCSR0=0xFE02E080, CSR3=0x300613C0, CSR4=0x30061800, CSR5=0xFC660000CSR6=0x320CA002, CSR7=0xFFFFA261, CSR8=0xE0400000, CSR9=0xFFFDC3FFCSR11=0xFFFE0000, CSR12=0xFFFFFF09, CSR15=0xFFFFFEC8DEC21140 PCI registers:bus_no=2, device_no=0CFID=0x00091011, CFCS=0x22800006, CFRV=0x02000022, CFLT=0x0000FF00CBIO=0x08312001, CBMA=0x01800000, CFIT=0x28140100, CFDA=0x00000000MII registers:Register 0x00: 2000 784F 2000 5C01 0081 0000 0000 0000Register 0x08: 0000 0000 0000 0000 0000 0000 0000 0000Register 0x10: 0000 0000 0000 0009 0000 0001 8060Register 0x18: 8020 0820 0000 3800 A3B9 :

(display text omitted):

61Input/Output Controller Replacement Instructions

OL-4447-02

Page 62: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Troubleshooting

The field that indicates overrun is CSR8 (shown in bold in the output above). This field is in hexadecimal format. To determine an overrun value, take the first four (high-order) digits, drop the first one from the left, convert the remaining three digits to the decimal equivalent, and then divide that number in half.

In the example above, overflows are recorded in CSR8 = 0xE0400000. To determine the overflow value from this example, take the first four (high-order) digits (E040), drop the first digit (E), and convert the remaining number (040) to the decimal equivalent (64). Then divide that number in half. The overrun value in this example is 32.

TroubleshootingUse Table 14 to diagnose problems.

Table 14 Troubleshooting

I/O Controller NPE /NSE Problem/Symptom Solution

C7200-I/O-GE+E or C7200-I/O-2FE/E

— • Erroneous environmental warning messages

• The router powers down; the router does not boot

• The router crashes or drops back to ROMmon

• The router does not recognize the interfaces on the C7200-I/O-GE+E and C7200-I/O-2FE/E I/O controllers

If the router is up, download the correct boot helper (boot loader) image from Cisco.com and replace the down-rev boot helper in boot flash memory.

If the router does not come up (is stuck in ROMmon), boot from other Flash devices (PCMCIA). See Table 11 on page 21 for the correct boot helper (boot loader) image. For information on accessing Cisco.com, see page 82.

— When booting with an C7200-I/O-GE+E or C7200-I/O-2FE/E I/O controller with 12.0(6)S c7200-boot-mz boot loader image:

• Environmental monitor warnings occur every five minutes as the voltages are incorrectly reported as high.

• The router displays the following port adapter warning message:

PA-3-NOTSUPPORTEDBYLOADER: Port Adapter type 534 in bay 0 is not supported by this boot loader

Use the c7200-kboot-mz enhanced boot loader image in Cisco IOS Release 12.0(14)S, 12.1(3a)E, or 12.1(5)T or later releases of Cisco IOS Releases 12.0 S, 12.1 E, and 12.1 T.

— The Cisco uBR7246VXR router does not recognize the UBR7200-I/O-2FE/E I/O controller and displays the following warning message:

%UBR7200-3-IONOTSUPPORTEDBYLOADER: I/O Controller (type 533) is not supported by this boot loader. The I/O Controller network interfaces will be unavailable.

Use only the Cisco IOS Release 12.1(10)EC version of the ubr7200-boot-mz image (ubr7200-boot-mz.121-10.EC), or later Release 12.1 EC version, as your boot helper (boot loader) image for the UBR7200-I/O-2FE/E I/O controller.

— The Cisco uBR7223 or Cisco uBR7246 router does not boot or recognize the UBR7200-I/O-2FE/E I/O controller.

The UBR7200-I/O-2FE/E controller supports only the Cisco uBR7246VXR router.

62Input/Output Controller Replacement Instructions

OL-4447-02

Page 63: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Troubleshooting

— Cannot insert the I/O controller in the chassis The C7200-I/O-GE+E and the C7200-I/O-2FE/E I/O controllers operate only in Cisco 7204VXR, Cisco 7206VXR, and Cisco uBR7246VXR chassis.

— The following error message displays:

%c7200-3-IONOTSUPPORTEDBYLOADER: I/O controller (type 539) is not supported by this boot loader. The I/O controller network interfaces will be unavailable.

You are attempting to use the standard boot image. These I/O controllers require the c7200-kboot-mz enhanced boot image for full functionality. Update the boot image in boot flash.

NPE-100 and NPE-150

The router powers down immediately after being powered on. (The NPE-100 and NPE-150 require that there be a boot ROM present on the I/O controller; however, the C7200-I/O-GE+E and the C7200-I/O-2FE/E I/O controllers do not have a boot ROM component.)

The NPE-100 and NPE-150 are not supported with the C7200-I/O-GE+E or C7200-I/O-2FE/E I/O controllers.

NPE-175 The system software automatically disables the ports on the I/O controller.

The NPE-175 is not supported with the C7200-I/O-GE+E or C7200-I/O-2FE/E I/O controller.

NPE-200 The router boots from ROMMON but a variety of errors occurs when attempting to boot IOS. The router may hang, crash with a PCI bus error, or fail to recognize PCMCIA cards.

The NPE-200 is not supported with the C7200-I/O-GE+E or C7200-I/O-2FE/E I/O controller.

C7200-I/O-GE+E NPE-225 Error message at bootup:

PA-3-UNSUPPORTED: PA in slot0 (GigabitEthernet/Ethernet (with GBIC/RJ45) I/O Card) is not supported on this chassis or npe cpu card

The NPE-225 is not supported with the C7200-I/O-GE+E I/O controller.

C7200-I/O-2FE/E NPE-225 The router does not work.

The C7200-I/O-2FE/E I/O controller in a Cisco 7204VXR or Cisco 7406VXR only operates with this version of NPE-225: board label 72-3453-05 rev AO or higher, or faceplate label 800-05418-03 AO or higher.

To check for the correct NPE-225 version in software, use the show c7200 command. Under CPU EEPROM, look for Hardware Revision 1.3 or higher.

Replace the NPE-225 with the correct version: NPE-225 board label 72-3453-05 rev AO or higher, or faceplate label 800-05418-03 AO or higher.

C7200-I/O-FE — Cisco 7202 router displays the following message:

%c7200-3-UNSUPPORTED: FE in slot0 is not supported on a c7202 chassis.

Remove the C7200-I/O-FE I/O controller from the Cisco 7202 router and install a C7200-I/O controller.

Table 14 Troubleshooting (continued)

I/O Controller NPE /NSE Problem/Symptom Solution

63Input/Output Controller Replacement Instructions

OL-4447-02

Page 64: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Connection Equipment and Port Signaling

Connection Equipment and Port SignalingThis section contains connection equipment and pinout information for the Ethernet, Fast Ethernet, Gigabit Ethernet, console, and auxiliary ports that are located on the I/O controller.

Note You can install an I/O controller with or without a Fast Ethernet port in Cisco 7200 series routers (including a Cisco 7206 and Cisco 7206VXR as router shelves in a Cisco AS5800 universal access server); however, when you install an I/O controller with a Fast Ethernet port in a Cisco 7202, the system software automatically disables the port. Therefore, the Fast Ethernet port connection equipment and pinout information in this section does not apply to a Cisco 7202 that has an installed I/O controller with a Fast Ethernet port.

Ethernet and Fast Ethernet RJ-45 Connection EquipmentThe I/O controller has RJ-45 ports for Ethernet, Fast Ethernet, or autosensing Ethernet and Fast Ethernet connections, depending on your model. The RJ-45 ports support IEEE 802.3(Ethernet), and IEEE 802.3u (Fast Ethernet) interfaces compliant with 10BASET and 100BASETx specifications.

The RJ-45 ports support standard straight-through and crossover Category 5 UTP cables with RJ-45 connectors. (See Figure 35.) Cisco Systems does not supply Category 5 UTP cables; these cables are available commercially.

Figure 31 shows an RJ-45 port and connector. Table 15 lists the pinouts and signals for the RJ-45 port.

Figure 31 RJ-45 Port and Connector

— You cannot upgrade the UBR7200-I/O-FE I/O controller to the Cisco IOS Release 12.1(10)EC boot helper image because of the following error message:

%Error copying ubr7200-boot-mz.121-10.EC (No space left on device)

You cannot use the Cisco IOS Release 12.1(10)EC version of the ubr7200-boot-mz boot helper (boot loader) image with the UBR7200-I/O-FE I/O controller. Instead, use the boot helper image from Cisco IOS Release 12.0(15)SC.

— Only one port is operational at a time. Use only one port, either the RJ-45 port or the MII port, not both. The port adapter has one port, but a choice of ports.

Table 14 Troubleshooting (continued)

I/O Controller NPE /NSE Problem/Symptom Solution

1 RJ-45 port

5757

4

12345678

1

64Input/Output Controller Replacement Instructions

OL-4447-02

Page 65: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Connection Equipment and Port Signaling

Warning To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telephone-network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits. Some LAN and WAN ports both use RJ-45 connectors. Use caution when connecting cables. Statement 1021

Note With reference to the RJ-45 pinout in Table 15, proper common-mode line terminations should be used for the unused Category 5 UTP cable pairs 4/5 and 7/8. Common-mode termination reduces electromagnetic interference (EMI).

Caution To comply with EMI EN55022 Class B regulations, shielded Ethernet cables (p/n 72-1501-01) must be used with the UBR7200-I/O-2FE/E I/O controller in the Cisco uBR7246VXR router. Two shielded cables are included with the UBR7200-I/O-2FE/E I/O controller.

Depending on your I/O controller RJ-45 interface cabling requirements, use the pinouts shown in Figure 32 and Figure 33 for straight-through and crossover twisted-pair cable connections.

Figure 32 Straight-Through Cable Pinout, Ethernet Port to a Hub or Repeater

Figure 33 Crossover Cable Pinout, Ethernet Port to a DTE

Table 15 RJ-45 Port Pinouts

Pin Description

1 TxD+1

1. TxD = Transmit Data.

2 TxD–

3 RxD+2

2. RxD = Receive Data.

6 RxD–

Ethernet port Hub

1 TxD+2 TxD–

3 RxD+6 RxD–

1 RxD+2 RxD–

3 TxD+6 TxD– 38

582

Ethernet port

1 TxD+

2 TxD–

3 RxD+

6 RxD–

1 TxD+

2 TxD–

3 RxD+

6 RxD– 3858

3

DTE

65Input/Output Controller Replacement Instructions

OL-4447-02

Page 66: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Connection Equipment and Port Signaling

To determine whether a UTP cable is a crossover cable or a straight-through cable, hold the two RJ-45 connectors next to each other so you can see the colored wires inside the ends, as shown in Figure 34.

Figure 34 Crossover or Straight-Through Cable Identification

Examine the sequence of colored wires to determine the type of cable, as follows:

• Straight-through—The colored wires are in the same sequence at both ends of the cable.

• Crossover—The first (far left) colored wire at one end of the cable is the third colored wire at the other end of the cable.

Fast Ethernet MII Connection EquipmentThe MII port on the I/O controller is a 40-pin, D-shell-type connector that is configurable for 100 megabits per second (Mbps). The MII port supports IEEE 802.3u interfaces compliant with the 100BASEX and 100BASET standards. The MII connection requires an external transceiver that permits connection to 100BASEFX or 100BASET4 physical media. (See Figure 35.)

H56

63

66Input/Output Controller Replacement Instructions

OL-4447-02

Page 67: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Connection Equipment and Port Signaling

Figure 35 Fast Ethernet Port Connection

Caution Before connecting the transceiver to the MII port on the I/O controller, check the MII transceiver documentation (or with the transceiver manufacturer) to ensure that the transceiver responds to physical sublayer (PHY) address 0; otherwise, anomalies with the MII connection on the I/O controller might occur. (PHY address 0 is defined in the section 22.2.4.4 “PHY Address” of the IEEE 802.3u specification.) If you are unable to determine whether the transceiver responds to physical sublayer (PHY) address 0, we recommend using the transceiver’s “Isolation Mode” setting, if present.

Note To determine if an MII transceiver that is already connected to the MII port on the I/O controller responds to PHY address 0, ensure that the I/O controller Fast Ethernet port is configured as up and the MII port is configured as the media type, and then disconnect the transceiver from the MII port. If the Fast Ethernet port goes down, the transceiver responds to PHY address 0.

The type of media you use between the MII connection and your router, switch, or hub determines the appropriate connectors for the network side of your 100BASET transceiver.

Figure 36 shows the pin orientation of the MII port on the I/O controller.

The MII port uses 2-56 screw-type locks, called jackscrews, to secure the cable or transceiver to the port. MII cables and transceivers have knurled thumbscrews that you fasten to the jackscrews on the MII port and tighten with your fingers. Use the jackscrews to secure your MII cable to the MII port.

1 Optional Fast Ethernet port (MII port and RJ-45 port)

4 To transceiver, repeater, or DTE

2 MII connector 5 To repeater or DTE

3 RJ-45 connector

2

4 5

3

MII

EN R

J45

EN R

J45

LINK

1O P

WR

OK

RJ-45

CPU RESET

FAST ETHERNET INPUT/OUTPUT CONTROLLER

ENABLED

PCMCIA

EJECT

SLOT 0

SLOT 1

FE MII

8453

9

1

67Input/Output Controller Replacement Instructions

OL-4447-02

Page 68: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Connection Equipment and Port Signaling

Figure 36 MII Port

Table 16 lists the pinouts and signals for the I/O controller MII port.

Gigabit Ethernet GBIC Connection EquipmentThe Gigabit Interface Converter (GBIC) port is a 1000-Mbps optical interface in the form of an SC-type duplex port that supports IEEE 802.3z interfaces compliant with the 1000BASEX standard. (See Figure 37.)

Note The GBIC is a separately orderable part and does not ship installed in your I/O controller. You must install the GBIC before you connect the cables to it. (For GBIC installation and cabling instructions, refer to your router installtion guide.)

1 Pin 1 3 Pin 21

2 Jackscrew

8939

1

1

32

Table 16 MII Port Pinout

Pin In Out I/O Description

14–17 — Yes — Transmit Data (TxD)

12 Yes — — Transmit Clock (Tx_CLK)1

1. Tx_CLK and Rx_CLK are provided by the external transceiver.

11 — Yes — Transmit Error (Tx_ER)

13 — Yes — Transmit Enable (Tx_EN)

3 — Yes — MII Data Clock (MDC)

4–7 Yes — — Receive Data (RxD)

9 Yes — — Receive Clock (Rx_CLK)

10 Yes — — Receive Error (Rx_ER)

8 Yes — — Receive Data Valid (Rx_DV)

18 Yes — — Collision (COL)

19 Yes — — Carrier Sense (CRS)

2 — — Yes MII Data Input/Output (MDIO)

22–39 — — — Common (ground)

1, 20, 21, 40 — — — +5.0 volts (V)

68Input/Output Controller Replacement Instructions

OL-4447-02

Page 69: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Connection Equipment and Port Signaling

Figure 37 shows the simplex and duplex SC-type connectors on your multimode or single-mode optical fiber cables. For simplex connectors, two cables are required, one cable for transmit (TX) and a second cable for receive (RX). For duplex connectors, one cable that has both TX and RX connectors is required. You can use either simplex or duplex connectors for the C7200-I/O-GE+E.

Figure 37 GBIC Port Connections

Note We strongly recommend cleaning all optical fiber connections before reconnecting optical cables to equipment. For information about cleaning optical connectors see the Inspection and Cleaning Procedures for Fiber-Optic Connections document and the Compressed Air Cleaning Issues for Fiber-Optic Connections document..

Table 17 describes the available GBIC options and their product numbers.

Table 18 provides cabling specifications for the GBICs that you install in Gigabit Ethernet devices. Note that all GBIC ports have SC-type connectors. Also, the minimum cable distance for the GBIC-SX or WS-G5484 and GBIC-LX/LH or WS-G5486 (multimode fiber [MMF] and single-mode fiber [SMF]) is

1 To external 1000BASEX network 4 2 simplex connectors

2 1 duplex connector (TX and RX) 5 TX

3 To external 1000BASEX network 6 RX

1

23

4

6677

5

E T H E R N E T 0 / 1

G B I CR X

T X

5 6

Table 17 GBIC Options

Product Number GBIC Description

GBIC-SX= or WS-G5484=

Short wavelength (1000BASESX)

Operates on standard multimode fiber-optic link spans of up to 1804.46 ft (550 m).

GBIC-LX/LH= or WS-G5486=

Long wavelength/long haul (1000BASELX/LH)

Operates on single-mode and multimode fiber-optic link spans of up to 6.2 miles (10 km).

GBIC-ZX= or WS-G5487=

Extended distance (1000BASEZX)

Operates on ordinary single-mode fiber-optic link spans of up to 43.5 miles (70 km). Link spans of up to 62.14 miles (100 km) are possible using premium single-mode fiber or dispersion-shifted single-mode fiber.

69Input/Output Controller Replacement Instructions

OL-4447-02

Page 70: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Connection Equipment and Port Signaling

6.5 feet (2 m), and the minimum link distance for the GBIC-ZX or WS-G5487 is 6.2 miles (10 km) with an 8-dB attenuator installed at each end of the link. Without attenuators, the minimum link distance for the GBIC-ZX or WS-G5487 is 24.9 miles (40 km).

Note Optical fiber cables are commercially available; they are not available from Cisco Systems.

A mode-conditioning patch cord can be used with the GBIC-LX/LH or WS-G5486 to allow reliable laser transmission between the single-mode laser source on the GBIC and a multimode optical fiber cable. (For more information, refer to the installation and configuration guide for your Cisco 7200 series router.)

Warning Because invisible laser radiation may be emitted from the aperture of the port when no fiber cable is connected, avoid exposure to laser radiation and do not stare into open apertures. Statement 70

Warning Class 1 laser product. Statement 1008

Table 18 GBIC Port Cabling Specifications

GBICWavelength (nm) Fiber Type

Core Size (micron)

Modal Bandwidth (MHz/km)

MaximumCable Distance

SX 850 MMF1

1. Multimode fiber (MMF) only.

62.5 160 722 ft (220 m)

62.5 200 902 ft (275 m)

50.0 400 1640 ft (500 m)

50.0 500 1804 ft (550 m)

LX/LH 1300 MMF2 and SMF

2. A mode-conditioning patch cord (product number CAB-GELX-625 or equivalent) is required.

When using the GBIC-LX/LH or WS-G5486 with 62.5-micron diameter MMF, you must install a mode-conditioning patch cord between the GBIC and the MMF cable on both the transmit and the receive ends of the link when link distances are greater than 984 ft (300 m).

We do not recommend using the GBIC-LX/LH or WS-G5486 and MMF with no patch cord for very short link distance (tens of meters). The result could be an elevated bit error rate (BER).

62.5 500 1804 ft (550 m)

50.0 400 1804 ft (550 m)

50.0 500 1804 ft (550 m)

9/10 — 6.2 miles (10 km)

ZX 1550 SMF 9/10 — 43.5 miles (70 km)

SMF3

3. Dispersion-shifted single-mode fiber-optic cable.

8 — 62.1 miles (100 km)

70Input/Output Controller Replacement Instructions

OL-4447-02

Page 71: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Connection Equipment and Port Signaling

Warning Class 1 LED product. Statement 1027

Console and Auxiliary Port Connection EquipmentThe I/O controller has a DCE-mode console port for connecting a console terminal, and a DTE-mode auxiliary port for connecting a modem or other DCE device (such as a CSU/DSU or other router) to your router.

Note Both the console and the auxiliary ports are asynchronous serial ports; any devices connected to these ports must be capable of asynchronous transmission. (Asynchronous is the most common type of serial device; for example, most modems are asynchronous devices.)

The I/O controller uses two types of physical media for console port and auxiliary port connections. Table 19 describes the I/O controller console and auxiliary port media type for each model.

Before connecting a terminal to the console port, configure the terminal to match the router console port as follows: 9600 baud, 8 data bits, no parity, 2 stop bits (9600 8N2). After you establish normal router operation, you can disconnect the terminal.

For console and auxiliary port pinouts for each media type, see the “DB-25 Port Cabling and Pinouts” section on page 71 and the “RJ-45 Port Cabling and Pinouts” section on page 73.

DB-25 Port Cabling and Pinouts

The DB-25 ports and connectors conform to the EIA/TIA-232 serial data transfer standard for communications between DTE and DCE equipment. Figure 38 shows console and auxiliary port connections for DB-25 physical media.

Table 19 Console and Auxiliary Port Physical Media

Model Console Port Auxiliary Port

C7200-I/O-GE+E RJ-45 port RJ-45 port

C7200-I/O-2FE/E RJ-45 port RJ-45 port

C7200-I/O-FE DB-25 port DB-25 connector

C7200-I/O DB-25 port DB-25 connector

C7200-I/O-FE-MII DB-25 port DB-25 connector

71Input/Output Controller Replacement Instructions

OL-4447-02

Page 72: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Connection Equipment and Port Signaling

Figure 38 Console and Auxiliary Port DB-25 Connections

DB-25 Console Port Signals and Pinouts

Both Data Set Ready (DSR) and Data Carrier Detect (DCD) are supported on the C7200-I/O, C7200-I/O-FE, and C7200-I/O-FE-MII I/O controller and are active when the system is running. The Request To Send (RTS) signal tracks the state of the Clear To Send (CTS) input. The console port does not support modem control or hardware flow control. Table 20 lists the DB-25 console port signals for the C7200-I/O, C7200-I/O-FE, and C7200-I/O-FE-MII I/O controllers. The console port requires a straight-through EIA/TIA-232 cable.

1 Auxiliary port 3 Modem

2 Console port 4 Console terminal

2

4 5

3

MII

EN R

J45

EN R

J45

LINK

1O P

WR

OK

RJ-45

CPU RESET

FAST ETHERNET INPUT/OUTPUT CONTROLLER

ENABLED

PCMCIA

EJECT

SLOT 0

SLOT 1

FE MII

8453

9

1

Table 20 Console Port Signals for C7200-I/O, C7200-I/O-FE, and C7200-I/O-FE-MII

Pin1

1. Any pin not referenced is not connected.

Signal Direction Description

1 GND — Ground

2 TxD In Transmit Data

3 RxD Out Receive Data

6 DSR Out Data Set Ready (always on)

7 GND — Ground

8 DCD Out Data Carrier Detect (always on)

72Input/Output Controller Replacement Instructions

OL-4447-02

Page 73: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Connection Equipment and Port Signaling

DB-25 Auxiliary Port Signals and Pinouts

Table 21 lists the DB-25 auxiliary port signals for the C7200-I/O, C7200-I/O-FE, and C7200-I/O-FE-MII I/O controllers. The auxiliary port supports hardware flow control and modem control.

RJ-45 Port Cabling and Pinouts

For the C7200-I/O-GE+E and C7200-I/O-2FE/E I/O controllers, both the console and auxiliary ports use rollover cables with RJ-45 connectors. Adapters are available for connection to modems and other external communications equipment. (See Table 23.)

With an I/O controller installed in the router with an NPE-G1, the default console and auxiliary ports are on the I/O controller, and you cannot access the console and auxiliary ports on the NPE-G1.

Note Both the console and the auxiliary ports are asynchronous serial ports; any devices connected to these ports must be capable of asynchronous transmission. (Asynchronous is the most common type of serial device; for example, most modems are asynchronous devices.)

Before connecting a terminal to the console port, configure the terminal to match the router console port as follows: 9600 baud, 8 data bits, no parity, 2 stop bits (9600 8N2). After you establish normal router operation, you can disconnect the terminal.

Note When connecting to an auxiliary port on a Cisco 7200 VXR router, the port will not function at baud rates higher than 19.2k. If the baud rate on the connecting device is set higher than 19.2k, either garbled text or nothing will be displayed on the screen.

Table 21 Auxiliary Port Signals for C7200-I/O, C7200-I/O-FE, and C7200-I/O-FE-MII

Pin1

1. Any pin not referenced is not connected.

Signal Direction Description

2 TxD Out Transmit Data

3 RxD In Receive Data

4 RTS Out Request To Send (used for hardware flow control)

5 CTS In Clear To Send (used for hardware flow control)

6 DSR In Data Set Ready

7 GND — Signal Ground

8 DCD In Data Carrier Detect (used for modem control)

20 DTR Out Data Terminal Ready (used for modem control only)

Table 22 Pinouts for the RJ-45-to-DB-25 Adapters

Adapter DTE M/F Pins1 DCE M/F Pins MMOD Pins2

1 4 5 5

2 20 6 8

3 2 3 3

73Input/Output Controller Replacement Instructions

OL-4447-02

Page 74: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Connection Equipment and Port Signaling

Refer to Table 22 for a list of the pins used on the RJ-45-to-DB-25 adapters, used with an RJ-45 cable, to connect terminals and modems to the Cisco7200 series routers. The cable you use may be a roll-over cable or a straight cable.

A roll-over cable can be detected by comparing the two modular ends of the cable. Holding the cables in your hand, side-by-side, with the tab at the back, the wire connected to the pin on the outside of the left plug should be the same color as the pin on the outside of the right plug. If your cable was purchased from Cisco, pin 1 will be white on one connector, and pin 8 will be white on the other (a roll-over cable reverses pins 1 and 8, 2 and 7, 3 and 6, and 4 and 5). (See Figure 39.)

Figure 39 Identifying a Rollover Cable

The Cisco 7200 series routers ships with a rolled cable. Connection to a terminal or a modem will require an RJ-45-to-DB-25 adapter, and possibly a DB-25-to-DB9 adapter. Refer to Table 23 for the cable and adapter configurations that can be used to connect terminals and modems to the Cisco 7200 series routers.

4 7 7 7

5 7 7 7

6 3 2 2

7 6 20 20

8 5 4 4

1. The female data terminal equipment (FDTE) adapter that is available from Cisco is labeled “Terminal”.

2. The MMOD adapter that is available from Cisco is labeled “Modem”.

Table 22 Pinouts for the RJ-45-to-DB-25 Adapters (continued)

Adapter DTE M/F Pins1 DCE M/F Pins MMOD Pins2

1 Pin 1 3 Pin 8

2 Pin 1 and pin 8 should be the same color

8453

2

1 3

2

74Input/Output Controller Replacement Instructions

OL-4447-02

Page 75: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Connection Equipment and Port Signaling

Both ports are configured as asynchronous serial ports. Figure 40 shows the RJ-45 console and auxiliary port connections.

Figure 40 Console and Auxiliary Port RJ-45 Connections

A cable and adapter kit is available from Cisco Systems (product number ACS-2500ASYN=). Table 22 describes the cable and adapter configurations that can be used to connect terminals and modems to the console or the auxiliary port.

RJ-45 Console Port Signals and Pinouts

The C7200-I/O-2FE/E and C7200-I/O-GE+E I/O controller console ports do not support Data Carrier Detect (DCD). Table 24 lists the RJ-45 console port signals for the C7200-I/O-2FE/E and C7200-I/O-GE+E I/O controllers.

Table 23 Asynchronous Device Cabling Options

Access Server Port RJ-45 Cable Type DB-25 Adapter End Device

Console or auxiliary Rolled FDTE1

1. The FDTE RJ-45-to-DB-25 adapter is labeled “Terminal”.

Terminal

Console or auxiliary Straight FDCE Terminal

Auxiliary or console Rolled MMOD2

2. The MMOD RJ-45-to-DB-25 adapter is labeled “Modem”.

Modem

1 Auxiliary port 4 To modem or DCE

2 Console port 5 To console terminal

3 RJ-45 connectors

8452

7

LINK

C7200-I/O-GE+ECLA

SS 1 L

ED P

RODUCT

P

RODUKT M

IT K

LASSE 1

LED

PRO

DUIT

AVEC

VOYA

NT D

EL

D

E CLA

SSE 1PRO

DUCTO

LED

DE C

LASE 1

ETHERNET GIGABIT ETHERNET INPUT/OUTPUT CONTROLLER

CONSOLE

AUX

E 0

LINK

SLOT 0

GE 0RX TX

EJECT

PCMCIA

SLOT 1

ENABLED

CPURESET

IO P

WROK

1 2

3

4

5

75Input/Output Controller Replacement Instructions

OL-4447-02

Page 76: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Upgrading the Boot Helper (Boot Loader) Image

RJ-45 Auxiliary Port Signals and Pinouts

Table 25 lists the RJ-45 auxiliary port signals for the C7200-I/O-2FE/E and C7200-I/O-GE+E I/O controllers.

Upgrading the Boot Helper (Boot Loader) ImageThe boot helper (boot loader) image resides in Flash memory on the I/O controller and contains a subset of the Cisco IOS software. This image is used to boot your router from the network or to load Cisco IOS images onto the router. This image is also used if the system cannot find a valid system image.

Your boot helper (boot loader) image should correspond to the Cisco IOS release that is running on your router. When you upgrade your Cisco IOS software to the minimum required software release (see Table 11), we recommend that you also upgrade your boot helper (boot loader) image.

Table 24 Console Port Signals for C7200-I/O-2FE/E and C7200-I/O-GE+E

Pin Signal Direction Description

1 CTS Out Clear To Send (tracks RTS)

2 DSR Out Data Set Ready (always on)

3 RXD Out Receive Data

4 GND — Signal Ground

6 TXD In Transmit Data

7 DTR In Data Terminal Ready

8 RTS In Ready To Send

Table 25 Auxiliary Port Signals for C7200-I/O-2FE/E and C7200-I/O-GE+E

Pin Signal Direction Description

1 RTS Out Ready To Send

2 DTR Out Data Terminal Ready

3 TXD Out Transmit Data

41

1. RING is not supported on Cisco-supplied adapters. To use this pin, you must create a customized cable.

RING In Ring Indication

5 GND — Signal Ground

6 RXD In Receive Data

72

2. Pin 7 can be used as a DCD input for connection to a modem. The RJ-45-to-DB-25F adapter maps DCD to this pin when used with a straight-through cable. (See Table 22.)

DSR/DCD(RLSD) In Data Set Ready / Data Carrier Detect (Receive Line Signal Detect)

8 CTS In Clear To Send (tracks RTS)

76Input/Output Controller Replacement Instructions

OL-4447-02

Page 77: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Upgrading the Boot Helper (Boot Loader) Image

Note The Cisco 7200 boot image in Cisco IOS Release 12.0 and all Cisco IOS 12.1 releases is oversized. If you need to upgrade the Cisco 7200 boot image, use the boot image in Cisco IOS Release 12.0 S in place of the boot image in Cisco IOS Release 12.0 or Cisco IOS 12.1 releases.

Note The UBR7200-I/O-2FE/E I/O controller requires the boot helper image from Cisco IOS Release 12.1(10)EC (ubr7200-boot-mz.121-10.EC) or later Release12.1 EC image. Other boot helper images, such as the one from Cisco IOS Release 12.0(15)SC, will not recognize the UBR7200-I/O-2FE/E I/O controller.

Note Make sure you upgrade the boot helper (boot loader) image on any previously purchased I/O controller before attempting to boot a Cisco 7200 VXR or Cisco uBR7246VXR router that has a newly installed NPE-175, NPE-225, NPE-300, or NPE-400.

Note The C7200-I/O-GE+E and C7200-I/O-2FE/E I/O controllers require the c7200-kboot-mz boot image. The UBR7200-I/O-2FE/E I/O controllers require the ubr7200-kboot-mz boot image. Attempting to use the standard boot image results in no network boot interfaces with the following warning message displayed:

%c7200-3-IONOTSUPPORTEDBYLOADER: I/O controller (type 539) is not supported by this boot

loader. The I/O controller network interfaces will be unavailable.

To upgrade your boot helper (boot loader) image, obtain the most current boot helper image through Cisco.com and copy the new boot helper image to Flash memory on your router. For information on how to access Cisco.com, see the “Obtaining Documentation and Submitting a Service Request” section on page 82. Follow the Software Center link under Service and Support. You need to Login to retrieve files from the Software Center.

To obtain a boot helper (boot loader) image from Cisco.com and upgrade your boot flash memory, do the following:

Step 1 Download the boot helper (boot loader) image from Cisco.com to a Trivial File Transfer Protocol (TFTP) server.

Step 2 Reformat the Flash memory on your router as follows:

router# format bootflash:Format operation may take a while. Continue? [confirm]Format operation will destroy all data in "bootflash:". Continue? [confirm]Formatting sector ... Format of bootflash:complete

Note Reformatting Flash memory erases the current Flash memory contents.

Step 3 Copy the boot helper image from the TFTP server to Flash memory as follows:

router# copy tftp bootflash:Address or name of remote host []? biffSource filename []? c7200-boot-mz.120-5.SDestination filename [c7200-boot-mz.120-5.S]?

77Input/Output Controller Replacement Instructions

OL-4447-02

Page 78: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Installing and Removing a Flash Memory Card or Flash Disk

Accessing tftp://biff/c7200-boot-mz.120-5.S...Loading c7200-boot-mz.120-5.S from 192.168.254.254 (via Ethernet4/0):!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

[OK - 3132516/6264832 bytes] 3132516 bytes copied in 28.488 secs (111875 bytes/sec)

This completes the procedure for upgrading your boot helper (boot loader) image. For more detailed instructions on loading and maintaining system images and microcode, including boot helper images, refer to the Configuration Fundamentals Configuration Guide, which is available on Cisco.com.

Installing and Removing a Flash Memory Card or Flash DiskThe I/O controller has two PC Card slots: slot 0 (lower) and slot 1 (upper). (See Figure 41.)

Note For procedures that explain how to remove and replace the PC Card Flash Disk, refer to the Using the Flash Disk document that accompanies every Flash Disk shipped from the factory.

Note To avoid potential problems when you insert spare Flash memory cards in your router, we recommend that you reformat all of your Flash memory cards using the recommended minimum Cisco IOS software release for your platform during your regularly scheduled service times. (See Table 11 on page 21.)

The “Reformatting a Flash Memory Card or Flash Disk” section on page 80 explains how to reformat a Flash memory card.

To install a Flash memory card in either PC Card slot, complete the following steps:

Step 1 Orient the Flash memory card so that its connector end faces the appropriate slot. (See Figure 41.)

Step 2 Carefully guide the card into the slot until it mates with the slot connector, and the ejector button for the slot pops out toward you. (See Figure 41.)

78Input/Output Controller Replacement Instructions

OL-4447-02

Page 79: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Installing and Removing a Flash Memory Card or Flash Disk

Figure 41 Installing and Removing a Flash Memory Card

Note Flash memory cards do not insert all the way into the PC Card slots on the I/O controller; the end of the card protrudes from the I/O controller faceplate. Do not attempt to force the card past this point.

Some older Flash memory cards might have foil tape attached to the outside edge of the card. If you insert one of these cards into the upper PC Card slot (slot 1) of an I/O controller installed in a Cisco uBR7200 series router, it might be difficult to remove the card. You should use a new Flash memory card that does not have the foil tape, remove the foil tape from the older Flash memory card, or, if necessary, use small pliers to remove the Flash memory card.

This completes the procedure for installing a Flash memory card in either PC Card slot.

To remove a Flash memory card from either PC Card slot, complete the following steps:

Step 1 Press the ejector button on the slot. (See Figure 41.)

Step 2 Grasp the card and pull it from the slot.

Step 3 Place the card in an antistatic bag.

This completes the procedure for removing a Flash memory card from either PC Card slot.

1 Inserting the Flash memory card 3 Removing the Flash memory card

2 Pushing the eject button for the Flash memory card

1 3

C O M PAC T F L A S H

ORK PROCESSING ENGINE - G1

C O M PAC T F L A S H

ORK PROCESSING ENGINE - G1

2

C O M PAC T F L A S H

ORK PROCESSING ENGINE - G1

6677

6

79Input/Output Controller Replacement Instructions

OL-4447-02

Page 80: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Installing and Removing a Flash Memory Card or Flash Disk

Reformatting a Flash Memory Card or Flash DiskDepending on the circumstances, you might need to use a Flash memory card from another system to copy images or back up configuration files; however, you cannot boot from a Flash memory card that was formatted on another type of system. You must reformat the card before you can use it as a boot source.

Note For procedures that explain how to remove and replace the Flash Disk, refer to the Using the Flash Disk document that accompanies every Flash Disk shipped from the factory.

Note To avoid potential problems when you insert spare Flash memory cards in your router, we recommend that you reformat all of your Flash memory cards using the recommended minimum Cisco IOS software release for your platform during your regularly scheduled service times. (See Table 11 on page 21.)

Caution The following formatting procedure erases all information on the Flash memory card. To prevent the loss of important data that might be stored on a Flash memory card, proceed carefully. If you want to save the data on a Flash memory card, copy the data to a server before you format the card.

The formatting procedure assumes the following:

• You have already booted your Cisco 7200 series router or Cisco uBR7200 series router.

• You have access to a TFTP server (meaning you know its name and have connectivity to it) and at least one interface is available over which you can access this server, or a secondary Flash memory card.

Note To ensure access to a TFTP server, you need to configure at least one network interface using the setup facility. Refer to the Configuration Fundamentals Configuration Guide publication for instructions on how to configure a network interface using the setup facility.

• You know the filename of the image you want to copy to the TFTP server or onto the secondary Flash memory card.

Use the following procedure to reformat a Flash memory card:

Step 1 Insert the Flash memory card into slot 0. (If slot 0 is not available, use slot 1.) See the “Installing and Removing a Flash Memory Card or Flash Disk” section on page 78.

Note Throughout this procedure, use slot0 or slot1 to refer to a Flash memory card. Use disk0 or disk1 to refer to a Flash Disk.

Step 2 Copy all the files on the Flash memory card to a TFTP server or a secondary Flash memory card. The following example is for copying files to a TFTP server:

Router> enablePassword: passwordRouter# copy slot0:image.name tftp

80Input/Output Controller Replacement Instructions

OL-4447-02

Page 81: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Fiber Optic Cleaning Information

Enter destination file name [image.name]: image.name CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCAddress or name of remote host [tftp.server.name]? tftp.server.name !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!Router#

Step 3 To reformat the Flash memory card, use the format slot0: (or format slot1:) command as follows:

Router# format slot0:All sectors will be erased, proceed? [confirm]Enter volume id (up to 30 characters): MyNewCardFormatting sector 1Format device slot0 completedRouter#

Step 4 Copy the files you saved to the TFTP server back to the Flash memory card as follows:

Router# copy tftp slot0Enter source filename: image.name20575008 bytes available on device slot0, proceed? [confirm]address or name of remote host [tftp.server.name]? tftp.server.nameloading new.image from tftp.server.name (via Ethernet1/0):!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!![OK - 7799951/15599616 bytes]CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC

Router#

The Flash memory card is now reformatted and ready to use.

Fiber Optic Cleaning InformationWe strongly recommend cleaning all optical fiber connections before reconnecting optical cables to equipment. For information about cleaning optical connectors, see the Inspection and Cleaning Procedures for Fiber-Optic Connections document and the Compressed Air Cleaning Issues for Fiber-Optic Connections document..

FCC Class A ComplianceThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense.

81Input/Output Controller Replacement Instructions

OL-4447-02

Page 82: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Obtaining Documentation and Submitting a Service Request

You can determine whether your equipment is causing interference by turning it off. If the interference stops, it was probably caused by the Cisco equipment or one of its peripheral devices. If the equipment causes interference to radio or television reception, try to correct the interference by using one or more of the following measures:

• Turn the television or radio antenna until the interference stops.

• Move the equipment to one side or the other of the television or radio.

• Move the equipment farther away from the television or radio.

• Plug the equipment into an outlet that is on a different circuit from the television or radio. (That is, make certain the equipment and the television or radio are on circuits controlled by different circuit breakers or fuses.)

Note This product has been designed to meet these requirements. Modifications to this product that are not authorized by Cisco Systems, Inc., could void the various approvals and negate your authority to operate the product.

Note To comply with EN55022 Class B regulations, the UBR7200-I/O-2FE/E I/O controller and Cisco uBR7246VXR router must use shielded Ethernet cables (p/n 72-1501-01). Two shielded cables are included with the UBR7200-I/O-2FE/E I/O controller.

Obtaining Documentation and Submitting a Service RequestFor information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at:

http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html

Subscribe to the What’s New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free service and Cisco currently supports RSS version 2.0.

To open a service request by telephone, use one of the following numbers:

Asia-Pacific: +61 2 8446 7411 (Australia: 1 800 805 227)EMEA: +32 2 704 55 55USA: 1 800 553-2447

For a complete list of Cisco TAC contacts, go to this URL:

http://www.cisco.com/techsupport/contacts

Obtaining Additional Publications and InformationInformation about Cisco products, technologies, and network solutions is available from various online and printed sources.

• Cisco Marketplace provides a variety of Cisco books, reference guides, documentation, and logo merchandise. Visit Cisco Marketplace, the company store, at this URL:

http://www.cisco.com/go/marketplace/

82Input/Output Controller Replacement Instructions

OL-4447-02

Page 83: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Obtaining Additional Publications and Information

• Cisco Press publishes a wide range of general networking, training and certification titles. Both new and experienced users will benefit from these publications. For current Cisco Press titles and other information, go to Cisco Press at this URL:

http://www.ciscopress.com

• Packet magazine is the Cisco Systems technical user magazine for maximizing Internet and networking investments. Each quarter, Packet delivers coverage of the latest industry trends, technology breakthroughs, and Cisco products and solutions, as well as network deployment and troubleshooting tips, configuration examples, customer case studies, certification and training information, and links to scores of in-depth online resources. You can access Packet magazine at this URL:

http://www.cisco.com/packet

• iQ Magazine is the quarterly publication from Cisco Systems designed to help growing companies learn how they can use technology to increase revenue, streamline their business, and expand services. The publication identifies the challenges facing these companies and the technologies to help solve them, using real-world case studies and business strategies to help readers make sound technology investment decisions. You can access iQ Magazine at this URL:

http://www.cisco.com/go/iqmagazine

or view the digital edition at this URL:

http://ciscoiq.texterity.com/ciscoiq/sample/

• Internet Protocol Journal is a quarterly journal published by Cisco Systems for engineering professionals involved in designing, developing, and operating public and private internets and intranets. You can access the Internet Protocol Journal at this URL:

http://www.cisco.com/ipj

• Networking products offered by Cisco Systems, as well as customer support services, can be obtained at this URL:

http://www.cisco.com/en/US/products/index.html

• Networking Professionals Connection is an interactive website for networking professionals to share questions, suggestions, and information about networking products and technologies with Cisco experts and other networking professionals. Join a discussion at this URL:

http://www.cisco.com/discuss/networking

• World-class networking training is available from Cisco. You can view current offerings at this URL:

http://www.cisco.com/en/US/learning/index.html

83Input/Output Controller Replacement Instructions

OL-4447-02

Page 84: Input/Output Controller Replacement Instructions · 4 Input/Output Controller Replacement Instructions OL-4447-02 Input/Output Controller Description Note Throughout this document

Obtaining Additional Publications and Information

This document is to be used in conjunction with the documents listed in the “Related Documentation” section.

Copyright © 2008, Cisco Systems, Inc.All rights reserved

CCVP, the Cisco logo, and Welcome to the Human Network are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn isa service mark of Cisco Systems, Inc.; and Access Registrar, Aironet, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, Cisco, the CiscoCertified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity,Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, Follow Me Browsing, FormShare, GigaDrive, HomeLink, Internet Quotient, IOS,iPhone, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, iQuick Study, LightStream, Linksys, MeetingPlace, MGX, Networkers,Networking Academy, Network Registrar, PIX, ProConnect, ScriptShare, SMARTnet, StackWise, The Fastest Way to Increase Your Internet Quotient,and TransPath are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.

All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply apartnership relationship between Cisco and any other company. (0711R)

84Input/Output Controller Replacement Instructions

OL-4447-02