  • ENhancedTEChnology

    www.entecene.co.kr

    Innovative Solution for DC Traction Power Supply

    Version 4.0

  • Remote evaluationvia modem orinternet(VPN)

    Central evaluation system

    Remote evaluationvia modem orinternet(VPN)

    Central evaluation system

    System Configuration of DC Traction Power Supply

  • ENTEC's Innovative Solution for DC Traction Power Supply 02 _ 03

  • ENTEC's advanced technology and endless innovation for DC Switchgear in DC Traction Power Systemwill contribute to a brighter approaching future. DC Switchgear is the essential equipment for SafeOperation in DC Traction Power System. ENTEC's DC Switchgears have been designed and optimizedfor DC Traction Power System and can also be utilized in heavy applications.

    CharacteristicsWide Range Current Interruption

    No dead zone

    High quality componentsHSCB and Diconnector designed for frequent operation duty

    Reliable protection relaySpecialized for Metro Power Traction Systemall information recorded

    Outstanding arc quenching technologyPatented Boil Coil designFrame free from spewed-out arc

    Rigid & Convenient DesignCompact design, easy installationwithdrawable HSCB truck, easy maintenance Strong cubicle structure by welding each part

    DC Switchgear for DC Traction Power System

    ❿❽

    ❹❺

    ❷Surge ArresterSurge (Lightening Surge,Inductive surge) prevention.

    ❶DC HSCB(Incl. truck)Fast fault current clearing in a faultoccasion.Several Interlock funtions areapplied in Circuit Breaker.

    ❻DC Power meter (kWh)Power consumption calculation.

    ❺ 64P (Voltage type)Monitoring earth voltage potential increasing and protect system.

    ❹ 64HR (Current type)Monitoring between DC livebus and enclosure, Protectearth current.

    ❼DC DisconnectorPower line close and openwhen no load.

    ❸FaultselectiveRelay(50F)Determine faults and operateCircuit Breaker (Digital type).

    ❾DC PTPrimary voltage sensing.

    ❿Communication Device❽DC CTCurrent Sensing.

  • ENTEC's Innovative Solution for DC Traction Power Supply 04 _ 05

    Nominal VoltageRated VoltageInsulation VoltageRated interrupting over voltageRated currentRated making and breaking capacityOperation dutydi/dt (Current rising rate vs time)Mechanical operationPower frequency withstand voltag (60Hz,1min.)Rated operation and control voltageOver current Release Pick-upMax. Ambient Temp / Avg. Temp.Altitude

    Size [Width x Depth x Height mm]*

    Weight [kg]IP protection (IEC 529)Applied standard

    DC 750VDC 900V

    DC 1,800V

    8.3kV/6.9kV

    650

    1.5 ~ 2 x rated voltage3000A/4000A/6000A

    178kAp/125kA 110kAp /76.8kAO-15sec-CO-15sec-CO-60sec-CO (max fault, max energy, distant fault)

    30.7 x 106A/S 24.2 x 106A/S40,000 times

    DC 110V / 220V2~8kA,6~12kA

    40℃ / 35℃≤2,000m

    > IP31IEC 61992

    DC 1,500VDC 1,800VDC 3,000V

    11kV/9.2kV

    700

    Model ETGR 21 ETGR 22Ratings

    Option Size [Depth] : 1,900mm(When adding a function of automatic withdrawal, for other sizes, discuss with maker)

    Rectifier, Feeder (600 x 1,800 x 2,200 / 600 x 1,500 x 2,200)Negative (1,500 x 1,800 x 2,200 / 1,200 x 1,200 x 2,200)

    OperationElectrical operation Mechanical Operation

    Manual closing device by requestClose HSCB without external power supply.

    Manual Closing Device(DC HSCB)

    Trip HSCB under emergencyMust be held when withdrawing or inserting HSCB

    Manual Trip Device(DC HSCB)

    Close or open Disconnection Switch(DS) without power supplyManual Close/Open(DC DS)

    (Fault selective Relay, DC Ground Relay, Undervoltage Relay, Reverse Current Relay, OCR,Intertripping Signal Relay, Lock-Out Relay)

    Trip by protection Relay System

    Trip by Direct Fault CurrentLocal Close/OpenRemote Close/Open

  • Standard Type and Test Graph

    Panel Type

    DC HSCB 'CO' Test Oscillogram

    Rectifier Feeder Spare Tie post Neg. DS

    Widrg[mm] 600 600 600 600 1,500

    Standard type

    Type Test

    Test Graph

    Disconnector Test Oscillogram

    Other application available upon user request.

  • ENTEC's Innovative Solution for DC Traction Power Supply 06 _ 07

    DC HSCB is used to manage DC Power Feeding line and interrupt a fault current.EDB Series is designed with the most advanced technology in order to protectRailway system from abnormality of Power feeding system. Under high frequencyswitching and heavy load condition, EDB Series DC HSCB is the most reliable choice.EDB Series have rated voltage of DC 900V for light weight railway system (EDB-09)and rated voltage of DC 1800V for urban and heavy railway system(EDB-18).

    DC High Speed Circuit Breaker(DC HSCB)

    Nominal voltageRated voltageRated currentRated interrupting over voltage

    Operation duty

    Mechanical OperationRated making and breaking capacityRated operation voltage

    Phase-Phase Phase-Ground Control Circuit

    Over current trip device(76I)Size[Width x Depth x Height]Applied standard

    DC 750VDC 900V

    345×913×831.5

    3000A / 4000A / 6000A1.5~2.5×Ue

    O-15sec-CO-15sec-CO-60sec-CO(max fault, max energy, distant fault)

    40,000 times178kAp / 125kA 110kAp / 76.8kA

    DC 110V / 220VAC 11kV/1minAC 9.2kV/1minAC 2kV/1min

    2~8kA, 6~12kA

    IEC 61992

    DC 1,500VDC 1,800V

    345×913×881.5

    Model EDB-09 EDB-18

    Ratings

    Insulationvoltage

    Enhanced small current interruption0 ~ rated making and breaking current

    High Durability and ReliabilityPMA Mechanism over 40,000 times of operationGuaranteed high speed overcurrent tripping

    Quality AssuranceInternational authorized laboratory(IPH CESI, KERI) type tested

    Sufficient current and thermal capacityHigh cooling efficiency 85 or lower under normal conditions.

    High Insulation capacity and increased interruption capabilityTo ensure personnel safetyTo fulfill heavy interrupting duty

    Optimized design with simple structureSimple installation, simple maintenance

    Panel InterfaceSmart interface with protection relay

    Characteristics

    DC HSCB

  • DC Diconnector & Load Break Switch

    1600A1000A1250A1600A6400A

    13000A120 cycles/h

    2500A20002500

    -10000A20000A

    60 cycles/h

    DC Disconnector is used for no load switching in DC system. ET-DS design is compactand optimized to be integrated in DC switchgear and other applications. In addition, sufficient insulation capacity and electric current capacity increase thesafety level of the product. Fast operation time is also appealing in perspective of userconvenience.

    Nominal voltageRated voltageRated currentRated short time currentOperation voltageOperation methodMechanical OperationOperation time

    Phase-PhasePhase-Ground Control Circuit

    Size[Width x Depth x Height]WeightApplied standard

    DC 750/1500VDC 900/1800V4000 / 6000A

    178kAp/125kADC 110V / 220VAuto / Manual100,000 times

    Below 2secAC11kV/1minAC9.2kV/1minAC 2kV/1min

    300×507×450mm32kg

    IEC 61992

    Model ET-DS

    Ratings

    Disconnector

    Load Break Switch

    Insulationvoltage

    DC LBS has been developed to provide making and breaking capacity to suit differentsituations. The safety and reliability are ensured by fast operating speed, safeinterruption of the arc and so on.

    Rated operational voltage UeRated insulation voltage UiRated impulse withstand voltage UimpNumber of polesFrame size

    Rated breaking capacityRated short-time withstand current Icw (1sec)Maximum electrical switching frequencyOverall dimensionsOperation temperatureVersions

    Mechanical durabilityRated control voltageStandard

    1500V3.82kV12kV

    3

    Please consult us-25 ~ +70

    Electric holding / Mechanical latch holding

    Insulated / Network with earthed negative polarity /Network with the mid-point earthed

    2 millionsDC 24, 48, 110, 220V, AC 220V

    IEC 60947-1, 60947-4-1

    Model ET-LBS

    Ratings

    Rated operational current

    According to the type of DC network

  • ENTEC's Innovative Solution for DC Traction Power Supply 08 _ 09

    VLD(Voltage Limiting Device)

    Real time rail voltage monitoringProtection against rail and / or earth voltage increasingSelective Ground Fault Protection

    Function of VLD (IEC62128-1)

    Rating Voltage [ V]Rated Current [A]Rated short-timeWithstand current [kA]

    HV contactorHV contactor + Thyristor

    Mechanism Life [times]Control Voltage [V]Standard

    1,250DC 900 DC 1,800

    50(250ms)

    DC 25 ~ 300V / 0~1,000sDC 300 ~ 1,000V / Inst.

    1,000,000DC 110V or AC 220V

    IEC61992-6, BS EN 50122

    Model ETOVPD 22Configuration & Specification

    Principle of VLD Maximum permissible touch voltage(IEC62128-1)

    Pick-upVoltage range

    Voltage limiting device

    ETCPU200or

    ETCPU300

    Fault Lamps

    V,A-Meter

    Control S/W

    Counter(Contactor & Thyristor)

    ❷HV. contactor❶Driver

    ❹DCCT ❺DCPT

    ❸ Thyristor

  • Protection Relay ETCPU & Interface software ETIMS

    ETCPU200 + ETHMI

    ETCPU300

    Various line protection functionVarious communication protocolsMonitoring function: Current, voltage, Delta-I, di/dt etc.Storage function: operation and fault event, fault waves etc.PLC functionMultiple language supportedInterface PC software

    With Interface Software ETIMS, ETCPU can be connected to and exchange data with a computer very easily and variousother functions can also be realized.

    System Setting

    PLC Edit

    System information

    System event

    Diagnostic event

    Load profile Wave form (Hourly)

    Load profile Wave form (Daily)

    Fault event

    Fault wave summary & Fault wave form

    Features

    Interface Software ETIMS

    Control Voltage [ V]Digital InputDigital OutputAnalog InputCommunicationData Saving

    SIZE(mm)

    Protection

    DC 110 V / AC 220 V

    IEC61850, IEC60870-5-101/104, DNP 3.0, ModBus, etcSystem history(1,000), Fault event(100), Fault waves(16), Load waves (3years), etc

    Fault elective relay(50F) / Over current relay(76D) / Voltage relay(45,80) /Ground fault relay(64P) / Reclosing relay(82)

    Model ETCPU 300ETCPU 200

    Ratings

    40 points24 points

    8 ch.((±20mA or ±10V)

    36 points24 points

    16 ch.((±20mA or ±10V)

    W275 D180 H160 W300 D240 H270

  • Earth

    Train location

    Potential betwee

    n

    rail and earth

    V(-)

    V(+)

    DC(+)

    A S/S(Sub sta tion)

    B S/S(Sub sta tion)

    DC(-) DC(+)DC(-)

    DC(+)

    F2F1

    DC(-)

    A S/S

    DC(+)

    CloseF2F1

    DC(-)

    B S/S

    Close

    DC(+)

    F2F1

    DC(-)

    C S/S

    DC(+)

    F2F1

    DC(-)

    D S/S

    VLD VLD VLD VLD VLD VLD VLD

    ENTEC's Innovative Solution for DC Traction Power Supply 10 _ 11

    SCMS (Stray Current Monitoring System)

    Generally, the amount of stray current can be estimated indirectly by measuring return circuit’s resistance value againstground or rail potential caused by rail operation because it is difficult to measure stray current directly.

    IMAX = 2.5 mA/m

    Principle of SCMS

    Voltage data acquisition, recording, plotting and real time monitoringAnalyzing of voltage data and alarmingReporting voltage data and VLD status historyData transmission to SCADA(through communication)Localization of the fault location

    Functions of SCMS

    VLDETCPU200 CMS (Central monitoring server)

    Line Overview Alarm Viewer Trade Page ManagerConfiguration of SCMS

    Reference electrode (IEC62128-2)

    Open formation GRE 0.5 S/km per trackVRE 5V

    Closed formationGRE 2.5 S/km per trackVRE 1V

  • 225-38 Choirubaekro, Bongdam-Eup, Hwaseong-City, Gyunggi-Do, Republic of KoreaPost Code : 18329TEL: +82-31-299-8400 FAX:+82-31-299-8401~2http://www.entecene.co.kr E-mail: [email protected]

    *Note. Product structure and arrangement shall be modified without notice. 1609

    High Efficiency ( 99%)Current Unbalance ratio less than +/- 10%Full Load Operation of the Diode n-1 Condition Graphic User Interface ApplicationReal-Time Monitoring System & AlertsCompact and Convenient Maintenance with design Rectifier Operation History Storage etc.

    Key Features

    Rated Input Voltage Rated Output Voltage

    Rated CurrentRated Frequency Over-load RatingInput SystemOutput PulseCooling MethodPower Frequency Withstand VoltageDiode TypeDiode Max Unbalanced CurrentFull Load Efficiency Maximum Noise StandardRated Control Voltage

    IP Protection (IEC 529)Apply standard

    *Rated Capacity

    Maximum Environmental Temperature/Avg. Temp(Days)/Avg. (Year)

    Model ETSR22ETSR21

    Ratings

    AC 300V (1,200V) DC 750V

    1,000/2,000kW

    1,333/2,667A

    2,350V

    AC 600V (1,200V) DC 1,500V

    2,000/3,000/4000kW

    1,333/2,000/2,667A

    4,140V

    * other ratings : consultation with customer

    50/60HzContinuous at 100% current / 2Hrs at 150% / 1Min at 300% (Class VI)

    Rectifier Tr ( / ‚ or / -Y) 6P or 12P

    Self-Cooling

    Silicone+/- 10%

    99% 60dB

    DC 110V and others

    40 /30 /25

    IP 31IEC 60146-1-1, 146-2 etc.

    Silicone Rectifier