Upload
ngothu
View
218
Download
4
Embed Size (px)
Citation preview
P2
SSNA
9000
Pow
er
Supp
lies
P
PMS
Sprecher + Schuh is proud to bring you the best in AC to DC power supplies.
Power from a Source you can TrustEstablished in 1991, ADEL System designs and manufactures high quality industrial power supplies. Their years of development effort, focused on switching technology, enables ADEL to satisfy a wide range of applications in industrial automation. This range of products can meet the most de-manding requirements for AC to DC switching power supplies.
ADEL system also manufacturers DC to DC switching, as well as linear power supplies, UPS systems and battery chargers. ADEL also designs custom power electronic solutions to fit the unique demands of special applications. A highly experienced engineering team insures high quality and cost-efficiency.
Quality to the Highest Standard100% of ADEL’s products are tested in the factory. Each product under-goes functional tests, or 2-hour run-in test at maximum operating voltage and current. The PSM product range features long duration electrolytic capacitors designed for long life in rugged industrial applications. The compatibility with CE requirements on electromagnetic interference is fully tested in the laboratory. The ADEL power supplies are backed with an extended 2-year warranty.
Industrial Switching Power Supplies
High Quality AC to DC power with up to 125% reserve capacity Unparalleled Benefits
ADEL system Power Supplies offer unparalleled benefits in the industry:• Metal Case IP 20 provides excel-
lent heat dissipation• 125% Reserve Power for 1 minute• Start-up demand up to 5 times
normal current for 500ms• Built-in overload protection• Internally fused for short-circuit
protection• 480V models for connection
without the need for control trans-formers
• Easy Installation, DIN Rail Mountable
Wide Range of ApplicationsADEL system Power Supplies can apply to numerous applications and industries:• PLC and Smart Relay power• Proximity Switches• Light Curtains• Textile & Robotic Machinery• Material Handling Equipment• Metal & Wood Working• Freezers & Refrigerators• Building Automation• Air Cleaning Systems• Packing Equipment
®C US
60950
508IND. CONT. EQ.
2-YearWarrantydiscontinued
P3
SSNA
9000
Pow
er
Supp
lies
P
PMS
Discount Schedule T-6
Input VoltageVAC Watts Output Voltage
VDCOutput Amps
Catalog Number Price
Single Phase
115-230 60 24 2.5 PSM242A 230
115-230 120 24 5 PSM244A 345
115 240 24 10 PSM2410A 500
230 240 24 10 PSM2410C 500
Two Phase 400-480 240 24 10 PSM2410B 625
Industrial Switching Mode Power Supplies
➊ Power supplies are UL508 approved allowing for application in industrial control equipment (control panels) without derating at 50ºC or less.➋ Power supplies are cCSAus approved under 60950 allowing for application in controlled environment (ie. computer rooms): 25ºC max, Pollution Category
No.2, Over Voltage category No.2.➌ CSA approval under 601010 allowing for application in industrial control panels: 40ºC max, Pollution Category No.3, Over Voltage category No.3 is pending.
Industrial Switch Mode Power SuppliesADEL system
Industrial Approvals ➊➋➌
®C US
60950508
IND. CONT. EQ.
discontinued
P4
SSNA
9000
Pow
er
Supp
lies
P
PMS
Discount Schedule T-6
PSM242AInput: single-phase 115 - 230 V ACOutput: One output 2.5 A @ 24 V DC 60 WattsStrong overload without switch-offShort-circuit protectionOver-voltage protectionIP20DIN Rail MountableExtremely small size
Input Data Input Rated Voltage (2 x V AC) 115…230 V ACRated Voltage range 93…264 V ACInrush Current (Vn – In) ≤ 11 A ≤ 5 msec.Frequency 47…63 HzInput Current (Input Rated Voltage) 0.9…0.5 AInternal Fuse Fast 4 AExternal Fuse (recommended) Fast 4 A
Output Data Output Voltage (Vn) / Nominal Current (In) 24 V DC ±3% / 2.5AAdjustment range (Vadj) 22…26 V DCStart up with Strong Load (capacitive load)
≤ 20.000 / ≤ 30.000µF
Switching on delay applying mains voltage
2.5 sec. (max)
Max. Continuous Current 1.1 x In ± 5%
Reserve Out Current (max. 1 min. 50 °C) Imax=In+25% approx.
Hold-up Time (at 100 – 240 V AC) Typ. 27 msecResidual Ripple ≤ 60 mVpp
Minimum Load NoEfficiency ≥ 81 %Short-circuit protection (hiccup mode) Yes Over Load protection (hiccup mode) Yes Over Voltage Output protection Yes (max 35 V DC)Parallel connection Yes
Climatic Data
Ambient Temperature (operation) -10…+70 °C (>50°derating)Ambient Temperature (Storage) -25…+85 °CHumidity; no moisture condensation 95 % to 25 °C
General Data
Isolation Voltage (Input/Output) 3000 V ACInput / ground isolation PE 1605 V ACOutput / ground isolation PE 500 V ACDegree of protection IP 20Protection class I with PE connectedDimension (w-h-d) 50x95x155 mmWeight 0.45 kg approx.
Norms and certificationsAccording to EMC 89/336/EEC and Low voltage 93/68/EEC
Electrical SafetyAccording to IEC/EN 60950 (VDE 0805) e EN 50178 (VDE 0160) for assembling device. The device must be installed according to IEC/EN 60950.
GenericImmunity according to EN50082-2 Level 4 Class BNoise Radiation according to EN 55011
Output Derating Curve
Output Characteristic Curve U/I
Industrial Switch Mode Power SuppliesTechnical Information
discontinued
P5
SSNA
9000
Pow
er
Supp
lies
P
PMS
Discount Schedule T-6
PSM244AInput: single-phase 115 - 230 V ACOutput: One output 5 A @ 24 V DC 120 WattsStrong overload without switch-offShort-circuit protectionOver-voltage protectionIP20DIN Rail MountableExtremely small size
Input Data Input Rated Voltage (2 x V AC) 115…230 V ACRated Voltage range 93…264 V ACInrush Current (Vn – In) ≤ 11 A ≤ 5 msec.Frequency 47…63 HzInput Current (Input Rated Voltage) 0.9…0.5 AInternal Fuse Fast 4 AExternal Fuse (recommended) Fast 4 A
Output Data Output Voltage (Vn) / Nominal Current (In)
24 V DC ±3% / 5A
Adjustment range (Vadj) 22…26 V DCStart up with Strong Load (capacitive load)
≤ 30.000µF
Switching on delay applying mains voltage
3 sec. (max)
Max. Continuous Current 1.1 x In ± 5%Reserve Out Current (max. 1 min. 50 °C) Imax=In+25% approx.Hold-up Time (at 100 – 240 V AC) Typ. 27 msecResidual Ripple ≤ 60 mVpp
Minimum Load NoEfficiency ≥ 82 %Short-circuit protection (hiccup mode) Yes Over Load protection (hiccup mode) Yes Over Voltage Output protection Yes (max 35 V DC)Parallel connection Yes
Climatic Data
Ambient Temperature (operation) -10…+70 °C (>50°derating)Ambient Temperature (Storage) -25…+85 °CHumidity; no moisture condensation 95 % to 25 °C
General Data
Isolation Voltage (Input/Output) 3000 V ACInput / ground isolation PE 1605 V ACOutput / ground isolation PE 500 V ACDegree of protection IP 20Protection class I with PE connectedDimension (w-h-d) 55x115x155 mmWeight 0.70 kg approx.
Norms and certificationsAccording to EMC 89/336/EEC and Low voltage 93/68/EEC
Electrical SafetyAccording to IEC/EN 60950 (VDE 0805) e EN 50178 (VDE 0160) for assembling device. The unit must be installed according to IEC/EN 60950.
GenericImmunity according to EN50082-2 Level 4 Class BNoise Radiation according to EN 55011
Industrial Switch Mode Power SuppliesTechnical Information
Output Derating Curve
Output Characteristic Curve U/I
discontinued
P6
SSNA
9000
Pow
er
Supp
lies
P
PMS
Discount Schedule T-6
PSM2410AInput: single-phase 115 V ACOutput: One output 10 A @ 24 V DC 240 WattsStrong overload without switch-offShort-circuit protectionOver-voltage protectionIP20DIN Rail MountableExtremely small size
Input Data Input Rated Voltage (2 x V AC) 115 V AC Rated Voltage range 90…132 V ACInrush Current (Vn – In) ≤ 14 A ≤ 5 msec.Frequency 47…63 HzInput Current (Input Rated Voltage) 3.5A maxInternal Fuse Fast 6.3 AExternal Fuse (recommended) Fast 6 A
Output Data Output Voltage (Vn) / Nominal Current (In) 24 V DC ±3% / 10AAdjustment range (Vadj) 22…26 V DCStart up with Strong Load (capacitive load) ≤ 30.000µFSwitching on delay applying mains voltage 2.5 sec. (max)Max. Continuous Current 1.1 x In ± 5%Reserve Out Current (max. 1 min. 50 °C) Imax=In+25% approx.Hold-up Time (at 100 – 240 V AC) Typ. 27 msecResidual Ripple ≤ 60 mVpp
Minimum Load NoEfficiency ≥ 86 %Short-circuit protection (hiccup mode) Yes Over Load protection (hiccup mode) Yes Over Voltage Output protection Yes (max 35 V DC)Parallel connection Yes
Climatic Data
Ambient Temperature (operation) -10…+70 °C (>50°derating)Ambient Temperature (Storage) -25…+85 °CHumidity; no moisture condensation 95 % to 25 °C
General Data
Isolation Voltage (Input/Output) 3000 V ACInput / ground isolation PE 1605 V ACOutput / ground isolation PE 500 V ACDegree of protection IP 20Protection class I with PE connectedDimension (w-h-d) 132x118x135 mmWeight 1.15 kg approx.
Norms and certificationsAccording to EMC 89/336/EEC and Low voltage 93/68/EEC
Electrical SafetyAccording to IEC/EN 60950 (VDE 0805) e EN 50178 (VDE 0160) for assembling device. The unit must be installed according to IEC/EN 60950.
GenericImmunity according to EN50082-2 Level 4 Class BNoise Radiation according to EN 55011
Output Derating Curve
Output Characteristic Curve U/I
Industrial Switch Mode Power SuppliesTechnical Information
discontinued
P7
SSNA
9000
Pow
er
Supp
lies
P
PMS
Discount Schedule T-6
PSM2410CInput: single-phase 230 V ACOutput: One output 10 A @ 24 V DC 240 Watts Strong overload without switch-offShort-circuit protectionOver-voltage protectionIP20DIN Rail MountableExtremely small size
Input Data Input Rated Voltage (2 x V AC) 230 V AC Rated Voltage range 187…264 V ACInrush Current (Vn – In) ≤ 14 A ≤ 5 msec.Frequency 47…63 HzInput Current (Input Rated Voltage) 3.5A maxInternal Fuse Fast 6.3 AExternal Fuse (recommended) Fast 6 A
Output Data Output Voltage (Vn) / Nominal Current (In)
24 V DC ±3% / 10A
Adjustment range (Vadj) 22…26 V DCStart up with Strong Load (capacitive load)
≤ 30.000µF
Switching on delay applying mains voltage
2.5 sec. (max)
Max. Continuous Current 1.1 x In ± 5%Residual Ripple ≤ 60 mVppMinimum Load NoEfficiency ≥ 86 %Short-circuit protection (hiccup mode) Yes Over Load protection (hiccup mode) Yes Over Voltage Output protection YesParallel connection Yes
Climatic Data
Ambient Temperature (operation) -10…+70 °C (>50°derating)Ambient Temperature (Storage) -25…+85 °CHumidity; no moisture condensation 95 % to 25 °C
General Data
Isolation Voltage (Input/Output) 3000 V ACInput / ground isolation PE 1605 V ACOutput / ground isolation PE 500 V ACDegree of protection IP 20Protection class I with PE connectedDimension (w-h-d) 132x118x135 mmWeight 1.15 kg approx.
Norms and certificationsAccording to EMC 89/336/EEC and Low voltage 93/68/EEC
Electrical SafetyAccording to IEC/EN 60950 (VDE 0805) e EN 50178 (VDE 0160) for assembling device. The unit must be installed according to IEC/EN 60950.
GenericImmunity according to EN50082-2 Level 4 Class BNoise Radiation according to EN 55011
AvailablePSM1210C (12V DC, 10 A)PSM0510C (5V DC, 10 A)
Industrial Switch Mode Power SuppliesTechnical Information
Output Derating Curve
Output Characteristic Curve U/I
discontinued
P8
SSNA
9000
Pow
er
Supp
lies
P
PMS
Discount Schedule T-6
PSM2410BInput: two-phase 400 - 480 V ACOutput: One output 10 A @ 24 V DC 240 WattsStrong overload without switch-offShort-circuit protectionOver-voltage protectionIP20DIN Rail MountableExtremely small size
Input Data Input Rated Voltage (2 x V AC) 400…480 V ACRated Voltage range 360…530 V ACInrush Current (Vn – In) ≤ 17 A ≤ 5 msec.Frequency 47…63 HzInput Current (Input Rated Voltage) 1…0.85 AInternal Fuse Fast 4 AExternal Fuse (recommended) Fast 4 A
Output Data Output Voltage (Vn) / Nominal Current (In) 24 V DC ±3% / 10AAdjustment range (Vadj) 22…26 V DCStart up with Strong Load (capacitive load) ≤ 30.000µFSwitching on delay applying mains voltage 2.5 sec. (max)Max. Continuous Current 1.1 x In ± 5%Reserve Out Current (max. 1 min. 50 °C) Imax=In+25% approx.Hold-up Time (at 100 – 240 V AC) Typ. 27 msecResidual Ripple ≤ 60 mVpp
Minimum Load NoEfficiency ≥ 89 %Short-circuit protection (hiccup mode) Yes Over Load protection (hiccup mode) Yes Over Voltage Output protection Yes (max 35 V DC)Parallel connection Yes
Climatic Data Ambient Temperature (operation) -10…+70 °C (>50°derating)Ambient Temperature (Storage) -25…+85 °CHumidity; no moisture condensation 95 % to 25 °C
General Data Isolation Voltage (Input/Output) 3000 V ACInput / ground isolation PE 1605 V ACOutput / ground isolation PE 500 V ACDegree of protection IP 20Protection class I with PE connectedDimension (w-h-d) 132x118x135 mmWeight 1.15 kg approx.
Norms and certificationsAccording to EMC 89/336/EEC and Low voltage 93/68/EEC
Electrical SafetyAccording to IEC/EN 60950 (VDE 0805) e EN 50178 (VDE 0160) for assembling device. The unit must be installed according to IEC/EN 60950.
GenericImmunity according to EN50082-2 Level 4 Class BNoise Radiation according to EN 55011
Industrial Switch Mode Power SuppliesTechnical Information
Output Derating Curve
Output Characteristic Curve U/I
discontinued
P9
SSNA
9000
Pow
er
Supp
lies
P
PMS
Discount Schedule T-6
Industrial Switch Mode Power SuppliesTechnical Information
Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.
PSM242A PSM244A
PSM2410A, PSM2410C and PSM2410B
discontinued
P10
SSNA
9000
Pow
er
Supp
lies
P
FLEX
Sprecher + Schuh is proud to bring you a new Flexible Power Supply from the best in AC to DC power supplies, Adel System.
Solutions for Power Supply ContinuityThe new FLEXline DC Power Supplies offer more power and flexibility for all your power needs. FLEX units are power rated from 100 to 150%, have a voltage input from 115V to 500V, and three modes of output circuit protec-tion. The extremely compact housings offer a variety of features.
Unparalleled BenefitsADEL system Power Supplies offer unparalleled benefits in the industry:• High quality AC to DC power
boost with up to 150% of rated output to 60ºC
• 1- and 2-phase input from 230V to 500V AC eliminates the need for control transformers
• Hiccup, Manual Reset and Continu-ous Output protection modes
• Operating temperature range of -25/+70ºC
• Metal Case IP 20 provides excel-lent heat dissipation
• Built-in overload protection• Internally fused for short-circuit
protection• Easy Installation, DIN Rail
Mountable• Five year warranty
Flexible Switching Power Supplies
High Quality AC to DC power with power boost up to 150% of rated Output to 60ºC
One Solution, Many ApplicationsADEL system Power Supplies can apply to numerous applications and industries:• PLC and Smart Relay power• Proximity Switches• Light Curtains• Textile & Robotic Machinery• Material Handling Equipment• Metal & Wood Working• Freezers & Refrigerators• Building Automation• Air Cleaning Systems• Packing Equipment
RoHS✔
5-Year
Warranty
P11
SSNA
9000
Pow
er
Supp
lies
P
FLEX
Discount Schedule T-6
Three Modes of ProtectionWith the exception of FLEX6024A, all Flex Models are field selectable via a factory supplied jumper for the three protection modes as described below.
Hiccup Mode Automatic RestartThis is the default factory setting ofall FLEX units. In case of short-circuitor overloading, the output currentis interrupted. The device triesagain to re-establish output voltageand normal condition about every 2second till the problem is cleared.
Hiccup Mode
Manual Reset
Fold-back Mode (Continuous Output)
Manual ResetIn case of short-circuit or overload,the output current is interrupted.In order to restart the output it isnecessary to switch-off the inputcircuit for about 1 minute.This protection mode is particularlysuggested in applications wheresafety procedures require that resetbe carried out only by an authorizedperson.
•"Power Good" Contacts
• Output (Load side)
• Enable Parallel Connection
• Adjust Output 22…27 VDC
• LED Status "OK"
• Field selectable via factory supplied jumper
Hiccup Manual Fold-back Mode Restart (continuous
(default) output)
• Set Voltage Selection (Slide switch in casing)
• Input (Input voltage)
Fold-back mode (Continuous Output mode)In case of short-circuit or overload,the output current is kept at highvalues with near zero voltage. In caseof short circuit the current can reachup to 3 times the rated current at60°C. This protection mode is used tomeet the requirements of demandingloads such as motors, solenoid valves,lamps, PLC with highly capacitiveinput circuits and other loads withmarked transient overload behavior. FLEX6024A is factory set to Fold-back (continuous) mode only.
P12
SSNA
9000
Pow
er
Supp
lies
P
FLEX
Discount Schedule T-6
Input Voltage
AC
Input Voltage
Selection ➌ Watts
Output
VDC
Output Amps PowerGood
Contact ➎
Catalog
Number ➍Price
@40ºC @50ºC
Single Phase115…230 Automatic 36…72
24
2 ➊ 1.5 ➋ ~ FLEX6024A 217
115/230 Selectable 96/120 5 4.5 Yes FLEX9024A 278
115/230 Selectable 120/180 7.5 6 Yes FLEX17024A 456
115/230 Selectable 240/336 14 12 Yes FLEX28024A 469
115/230 Selectable 480/600 25 22 Yes FLEX50024A 1079
Two Phase230/400…500 Selectable 96/120
24
5 4.5 Yes FLEX9024B 305
230/400…500 Selectable 120/180 7.5 6 Yes FLEX17024B 504
230/400…500 Selectable 240/336 14 12 Yes FLEX28024B 542
Three Phase400…500 Automatic 480…600 24 25 22 Yes FLEX50024B 760
Flexible Switching Mode Power Supplies
Flexible Switching Power SuppliesADEL system
Norms and certificationsThe CE mark in According to EMC 2004/108/EC and the Low voltage directive 2006/95/EC
Electrical SafetyAccording to UL508, UL file E308682, IEC/EN 60950 (VDE 0805) e EN 50178 (VDE 0160) for assembling device. The unit must be installed according to IEC/EN 60950. Input / Output separation: SELV EN60950-1 and PELV EN 60204-1. Double or reinforced insulation.
EMC ImmunityEN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-6-2
EMC Emission: EN 61000-6-4, EN61000-3-2
Standards ConformityEN 60204-1 Safety of Electrical Equipment Machines
➊ 115V Amp Rating shown; 3A @ 230V (72 W)➋ 115V Amp Rating shown; 2.5@ 230V (60 W)➌ Input voltage selectable via slide switch located below input
terminals inside metal casing.
➍ With the exception of Flex6024A, all models are capable of being set to hiccup mode, manual reset or Continuous mode via factory supplied jumper.
➎ The NO Power Good contact closes any time the output voltage falls below 20 VDC.
5-Year
Warranty
P13
SSNA
9000
Pow
er
Supp
lies
P
FLEX
Discount Schedule T-6
FLEX6024AInput: single-phase 115 … 230 V ACOutput: One output 24 V DC 50ºCEfficiency up to 88%Strong overload without switch-off upFlexible power continuity: 36 to 72 WDIN Rail MountableExtremely small size
Input Data Nominal Input Voltage (2 x Vac) 115 … 230 Vac Input Voltage range (Vac) 90 … 264 Inrush Current (Vn and In Load) I2t ≤ 7 A ≤ 5 msec. Frequency 47 – 63 Hz ±6% Input Current (115 – 230 Vac) 1 – 0.7 A Internal Fuse T 4 A External Fuse (recommended) 6 A (MCB curve B)
Output Data Output Voltage (Vn) Factory Setting 3% 24 Vdc Adjustment range (Vadj) 22 – 27 Vdc Start up with Strong Load (capacitive load) ≤ 50.000 µFTurn-On delay after applying mains voltage 1.5 sec. (max) Continuous Current at 24 V < 40°C (In) 2 A (115) 3 A (230) Continuous Current at 24 V < 50°C (In) 1.5 A (115) 2.5 A (230) Power Boost Current at 24 Vdc 50°C(In) 3.5A ≥ 3 min. Current max. Overload 4Vdc (permanent) Imax = In 50°C x (1.8 - 2.2) Max current Short Circuit (Icc) 7 AHold-up Time ( min. Vac) 24Vdc 5A Typ. 20 msecResidual Ripple ≤ 80 mVpp Efficiency ≥ 88 % Over temperature Protection Yes. Shut-down output and
automatic restart. Short-circuit protection Yes, Continuous Mode Dissipation power load max (W) 6 Over Load protection Yes, Continuous Mode Over Voltage Output protection Yes (typ. 35 Vdc) Parallel connection Yes
Climatic
Data
Ambient Temperature operation -25 up to +70 °C (>50°derating 2.5% °C)
Ambient Temperature Storage -40 up to +85 °C Humidity at 25 °C, no condensation 95 % to 25 °C
General
Data
Isolation Voltage (In / Out) 3000 Vac Isolation Voltage (In / PE) 1605 Vac Isolation Voltage (Out / PE) 500 Vac Protection Class (EN/IEC 60529) IP 20 Reliability: MTBF IEC 61709 > 500.000 h Pollution Degree Environment 2 Protection class I with PE connected Dimension (w-h-d) 50x120x50 mm Weight 0.3 kg approx.
Terminal
Connections
Solid (mm2)
Stranded (mm2)
AWG
Torque (NM)
Stripped Length:
Input: 0.2-2.5 0.2-2.5 24-14 0.5-0.6 7 mmOutput: 0.2-2.5 0.2-2.5 24-14 0.5-0.6 7 mm
Output derating Curve
Continuous Load
020406080
100120140160
-10 0 10 20 30 40 50 60 70 °C
%
Output Voltage vs. Output Current, typ.
Continuou...
0
4
8
12
16
20
24
28
0 1 2 3 4 5 6 7
Load (A)
Out Voltage
Flexible Switching Power SuppliesTechnical Information
1-PH
72Wmax
RoHS✔
UL File E308682
P14
SSNA
9000
Pow
er
Supp
lies
P
FLEX
Discount Schedule T-6
Flexible Switching Power SuppliesTechnical Information
FLEX9024AInput: single-phase 115 / 230 V ACOutput: One output 24 V DC 60ºCEfficiency up to 91%Strong overload without switch-off, up to 50%Flexible power continuity: 96 to 120 W"Power Good" ContactSelectable Protection Mode: Hiccup, Fold back (continuous) & Restart after MainDIN Rail Mountable
Extremely small size Input Data Nominal Input Voltage (2 x Vac)
Manual select Input from 115 to 230 115 / 230 Vac
Input Voltage range (Vac) 90 – 135 (115) 180 – 264 (230)
Inrush Current (Vn and In Load) I2t ≤ 11 A ≤ 5 msec. Frequency 47 – 63 Hz ±6% Input Current (115 – 230 Vac) 1.8 – 0.9 A Internal Fuse T 4 A External Fuse (recommended) 10 A (MCB curve B)
Output Data Output Voltage (Vn) Factory Setting ±3% 24 Vdc Adjustment range (Vadj) 22 – 27 Vdc Start up with Strong Load (capacitive load) ≤ 50.000 µF Turn-On delay after applying mains voltage 1 sec. (max) Continuous Current at 24 V < 40°C (In) 5 A (permanent) Continuous Current at 24 V < 50°C (In) 4.5 A (permanent) Continuous Current at 24 V < 60°C (In) 4 A (permanent) Power Boost Current at 24 Vdc 60°C(In) In (60°C) x 1.5 ≥ 3 min. Current max. Overload �~= 4Vdc (permanent) Imax = In 60°C x (1.8 - 2.2) Current Short Circuit Icc
Max 2 sec.: Hiccup mode Permanent : Fold back (Continuous) Mode
12 A
Hold-up Time ( min. Vac) 24Vdc 5A Typ. 20 msec Residual Ripple ≤ 80 mVpp Efficiency ≥ 91 % Over temperature Protection Yes. Shut-down output and
automatic restart. Short-circuit protection modes
Hiccup Mode Fold BackRestart After Main
Dissipation power load max (W) 11 Over Load protection Yes Over Voltage Output protection Yes (typ. 35 Vdc) Parallel connection Yes Power Good contact rating (EN60947.4.1): Max. DC1: 30VDC 1S; AC1: 60 VAC 1A Min. 1mA at 5 VDC
Resistive load Min. permissive load
Climatic
Data
Ambient Temperature operation -25 up to +70 °C (>60°derating 2.5% °C)
Ambient Temperature Storage -40 up to +85 °CHumidity at 25 °C, no condensation 95 % to 25 °C
General
Data
Isolation Voltage (In / Out) 3000 VacIsolation Voltage (In / PE) 1605 VacIsolation Voltage (Out / PE) 500 VacProtection Class (EN/IEC 60529) IP 20Reliability: MTBF IEC 61709 > 500.000 hPollution Degree Environment 2Protection class I with PE connectedDimension (w-h-d) 55x110x105 mmWeight 0.50 kg approx.
Terminal
Connections
Solid (mm2)
Stranded (mm2)
AWG
Torque (NM)
Stripped Length:
Input: 0.2-2.5 0.2-2.5 24-14 0.5-0.6 7 mmOutput: 0.2-2.5 0.2-2.5 24-14 0.5-0.6 7 mm
RoHS✔
UL File E308682
1-PH
120Wmax
P15
SSNA
9000
Pow
er
Supp
lies
P
FLEX
Discount Schedule T-6
FLEX17024AInput: single-phase 115 / 230 V ACOutput: 24 V DC 60ºCEfficiency up to 91%Strong overload without switch-off, up to 50%Flexible power continuity: 120 to 180 W"Power Good" ContactSelectable Protection Mode: Hiccup, Fold back (continuous) & Restart after MainDIN Rail Mountable
Extremely small size Input Data Nominal Input Voltage (2 x Vac)
Manual select Input from 115 to 230 115 / 230 Vac
Input Voltage range (Vac) 90 – 135 (115)180 – 264 (230)
Inrush Current (Vn and In Load) I2t ≤ 11 A ≤ 5 msec.Frequency 47 – 63 Hz ±6% Input Current (115 – 230 Vac) 2.8 – 1.3 AInternal Fuse T 4 AExternal Fuse (recommended) 10 A (MCB curve B)
Output Data Output Voltage (Vn) Factory Setting ±3% 24 Vdc Adjustment range (Vadj) 22 – 27 VdcStart up with Strong Load (capacitive load) ≤50.000µFTurn-On delay after applying mains voltage 1 sec. (max)Rated Current at 24 V < 40°C (In) 7.5 A (permanent)Rated Current at 24 V < 50°C (In) 6 A (permanent)Rated Current at 24 V < 60°C (In) 5 A (permanent)Power Boost Current at 24 V 60ºC(In) In (60ºC) x 1.5 ≥ 3 min.Current max. Overload �~= 4Vdc (permanent) Imax = In 60°C x (1.8 - 2.2) Current Short Circuit Icc
Max 2 sec.: Hiccup modePermanent: Fold back (Continuous) mode
16A
Hold-up Time ( min. Vac) 24Vdc 5A Typ. 20 msecResidual Ripple ≤ 80 mVpp
Efficiency ≥ 91 %Over temperature Protection Yes. Shut-down output and
automatic restart.Short-circuit protection modes Hiccup Mode
Fold BackRestart After Main
Dissipation power load max (W) 17 Over Load protection Yes Over Voltage Output protection Yes (typ. 35 Vdc)Parallel connection YesPower Good contact rating (EN60947.4.1): Max. DC1: 30VDC 1S; AC1: 60 VAC 1A Min. 1mA at 5 VDC
Resistive load Min. permissive load
Climatic
Data
Ambient Temperature operation -25 up to +70 °C (>60°derating 2.5% °C)
Ambient Temperature Storage -40 up to +85 °CHumidity at 25 °C, no condensation 95 % to 25 °C
General
Data
Isolation Voltage (In / Out) 3000 VacIsolation Voltage (In / PE) 1605 VacIsolation Voltage (Out / PE) 500 VacProtection Class (EN/IEC 60529) IP 20Reliability: MTBF IEC 61709 > 500.000 hPollution Degree Environment 2Protection class I with PE connectedDimension (w-h-d) 55x110x105 mmWeight 0.60 kg approx.
Terminal
Connections
Solid (mm2)
Stranded (mm2)
AWG
Torque (NM)
Stripped Length:
Input: 0.2-2.5 0.2-2.5 24-14 0.5-0.6 7 mmOutput: 0.2-2.5 0.2-2.5 24-14 0.5-0.6 7 mm
Flexible Switching Power SuppliesTechnical Information
Output derating Curve
Continuous Load
020406080
100120140160
-10 0 10 20 30 40 50 60 70 °C
%
Output Voltage vs. Output Current, typ.
16; 00
4
8
12
16
20
24
28
0 5 10 15 20
Load (A)
Out Voltage
RoHS✔
UL File E308682
1-PH
180Wmax
P16
SSNA
9000
Pow
er
Supp
lies
P
FLEX
Discount Schedule T-6
Flexible Switching Power SuppliesTechnical Information
FLEX28024AInput: single-phase 115 / 230 V ACOutput: 24 V DC 60ºCEfficiency up to 91%Strong overload without switch-off, up to 50%Flexible power continuity: 240 to 336 W"Power Good" ContactSelectable Protection Mode: Hiccup, Fold back (continuous) & Restart after MainDIN Rail Mountable
Extremely small size Input Data Nominal Input Voltage (2 x Vac)
Manual select Input from 115 to 230 115 / 230 Vac
Input Voltage range (Vac) 90 – 135 (115)180 – 264 (230)
Inrush Current (Vn and In Load) I2t ≤ 16 A ≤ 5 msec.Frequency 47 – 63 Hz ±6% Input Current (115 – 230 Vac) 3.3 – 2.2 AInternal Fuse T 6.3 AExternal Fuse (recommended) 16 A (MCB curve B)
Output Data Output Voltage (Vn) Factory Setting ±3% 24 Vdc Adjustment range (Vadj) 22 – 27 VdcStart up with Strong Load (capacitive load) ≤50.000µFTurn-On delay after applying mains voltage 1 sec. (max)Rated Current at 24 V < 40°C (In) 14 A (permanent)Rated Current at 24 V < 50°C (In) 12 A (permanent)Rated Current at 24 V < 60°C (In) 10 A (permanent)Power Boost Current at 24 V 60ºC(In) In (60ºC) x 1.5 ≥ 3 min.Current max. Overload �~= 4Vdc (permanent) Imax = In 60°C x (1.8 - 2.2) Current Short Circuit Icc
Max 2 sec.: Hiccup modePermanent: Fold back (Continuous) mode
30A
Hold-up Time ( min. Vac) 24Vdc 5A Typ. 20 msecResidual Ripple ≤ 80 mVpp
Efficiency ≥ 91 %Over temperature Protection Yes. Shut-down output and
automatic restart.Short-circuit protection modes Hiccup Mode
Fold BackRestart After Main
Dissipation power load max (W) 28 Over Load protection Yes Over Voltage Output protection Yes (typ. 35 Vdc)Parallel connection Yes, "Easy Parallel"Power Good contact rating (EN60947.4.1): Max. DC1: 30VDC 1S; AC1: 60 VAC 1A Min. 1mA at 5 VDC
Resistive load Min. permissive load
Climatic
Data
Ambient Temperature operation -25 up to +70 °C (>60°derating 2.5% °C)
Ambient Temperature Storage -40 up to +85 °CHumidity at 25 °C, no condensation 95 % to 25 °C
General
Data
Isolation Voltage (In / Out) 3000 VacIsolation Voltage (In / PE) 1605 VacIsolation Voltage (Out / PE) 500 VacProtection Class (EN/IEC 60529) IP 20Reliability: MTBF IEC 61709 > 500.000 hPollution Degree Environment 2Protection class I with PE connectedDimension (w-h-d) 72x115x135 mmWeight 0.65 kg approx.
Terminal
Connections
Solid (mm2)
Stranded (mm2)
AWG
Torque (NM)
Stripped Length:
Input: 0.2-2.5 0.2-2.5 24-14 0.5-0.6 7 mmOutput: 0.2-2.5 0.2-2.5 24-14 0.5-0.6 7 mmSignal: 0.2-2.5 0.2-2.5 24-14 0.5-0.6 7 mm
020406080
100120140160
-10 0 10 20 30 40 50 60 70
%
°C
Output derating CurveContinuous Load
Output Voltage vs. Output Current, typ.
0
4
8
12
16
20
24
28
0 10 20 30 40
Load (A)
Out Voltage
RoHS✔
UL File E308682
1-PH
336Wmax
P17
SSNA
9000
Pow
er
Supp
lies
P
FLEX
Discount Schedule T-6
FLEX50024AInput: single-phase 115 / 230 V ACOutput: 24 V DC 60ºCEfficiency up to 92%Strong overload without switch-off, up to 50%Flexible power continuity: 480 to 600 W"Power Good" ContactSelectable Protection Mode: Hiccup, Fold back (continuous) & Restart after MainDIN Rail Mountable
Extremely small size Input Data Nominal Input Voltage (2 x Vac)
Manual select Input from 115 to 230 115 / 230 Vac
Input Voltage range (Vac) 90 – 135 (115)180 – 264 (230)
Inrush Current (Vn and In Load) I2t ≤ 16 A ≤ 5 msec.Frequency 47 – 63 Hz ±6% Input Current (115 – 230 Vac) 8 – 4.2 AInternal Fuse T 10 AExternal Fuse (recommended) 16 A (MCB curve B)
Output Data Output Voltage (Vn) Factory Setting ±3% 24 Vdc Adjustment range (Vadj) 22 – 27 VdcStart up with Strong Load (capacitive load) ≤50.000µFTurn-On delay after applying mains voltage 1 sec. (max)Rated Current at 24 V < 40°C (In) 25 A (permanent)Rated Current at 24 V < 50°C (In) 22 A (permanent)Rated Current at 24 V < 60°C (In) 20 A (permanent)Power Boost Current at 24 V 60ºC(In) In (60ºC) x 1.5 ≥ 3 min.Current max. Overload ~= 4Vdc (permanent) Imax = In 60°C x (1.8 - 2.2) Current Short Circuit Icc
Max 2 sec.: Hiccup modePermanent: Fold back (Continuous) mode
60A
Hold-up Time ( min. Vac) 24Vdc 5A Typ. 20 msecResidual Ripple ≤ 80 mVpp
Efficiency ≥ 92 %Over temperature Protection Yes. Shut-down output and
automatic restart.Short-circuit protection modes Hiccup Mode
Fold BackRestart After Main
Dissipation power load max (W) 54 Over Load protection Yes Over Voltage Output protection Yes (typ. 35 Vdc)Parallel connection Yes, "Easy Parallel"Power Good contact rating (EN60947.4.1): Max. DC1: 30VDC 1S; AC1: 60 VAC 1A Min. 1mA at 5 VDC
Resistive load Min. permissive load
Climatic
Data
Ambient Temperature operation -25 up to +70 °C (>60°derating 2.5% °C)
Ambient Temperature Storage -40 up to +85 °CHumidity at 25 °C, no condensation 95 % to 25 °C
General
Data
Isolation Voltage (In / Out) 3000 VacIsolation Voltage (In / PE) 1605 VacIsolation Voltage (Out / PE) 500 VacProtection Class (EN/IEC 60529) IP 20Reliability: MTBF IEC 61709 > 500.000 hPollution Degree Environment 2Protection class I with PE connectedDimension (w-h-d) 85x120x140 mmWeight 0.75 kg approx.
Terminal
Connections
Solid (mm2)
Stranded (mm2)
AWG
Torque (NM)
Stripped Length:
Input: 4.0 6.0 30-10 0.8-1.0 7 mmOutput: 4.0 6.0 30-10 0.8-1.0 7 mmSignal: 0.2-2.5 0.2-2.5 24-14 0.5-0.6 7 mm
Flexible Switching Power SuppliesTechnical Information
RoHS✔
UL File E308682
1-PH
600Wmax
P18
SSNA
9000
Pow
er
Supp
lies
P
FLEX
Discount Schedule T-6
Flexible Switching Power SuppliesTechnical Information
FLEX9024BInput: two-phase 230 / 400 … 500 V ACOutput: 24 V DC 60ºCEfficiency up to 91%Strong overload without switch-off, up to 50%Flexible power continuity: 96 to 120 W"Power Good" ContactSelectable Protection Mode: Hiccup, Fold back (continuous) & Restart after MainDIN Rail MountableExtremely small size
Input Data Nominal Input Voltage (2 x Vac) Manual select Input from 230 to 400-500
230 / 400 … 500 Vac
Input Voltage range (Vac) 187 – 264 (230)330 – 550 (400-500)
Inrush Current (Vn and In Load) I2t ≤ 17 A ≤ 5 msec.Frequency 47 – 63 Hz ±6% Input Current (230/400…500 V AC) 1.0 – 0.5 – 0.4 AInternal Fuse T 4 AExternal Fuse (recommended) 10 A (MCB curve B)
Output Data Output Voltage (Vn) Factory Setting ±3% 24 Vdc Adjustment range (Vadj) 22 – 27 VdcStart up with Strong Load (capacitive load) ≤50.000µFTurn-On delay after applying mains voltage 1 sec. (max)Rated Current at 24 V < 40°C (In) 5 A (permanent)Rated Current at 24 V < 50°C (In) 4.5 A (permanent)Rated Current at 24 V < 60°C (In) 4 A (permanent)Power Boost Current at 24 V 60ºC(In) In (60ºC) x 1.5 ≥ 3 min.Current max. Overload �~= 4Vdc (permanent) Imax = In 60°C x (1.8 - 2.2) Current Short Circuit Icc
Max 2 sec.: Hiccup modePermanent: Fold back (Continuous) mode
12A
Hold-up Time ( min. Vac) 24Vdc 5A Typ. 20 msecResidual Ripple ≤ 80 mVpp
Efficiency ≥ 91 %Over temperature Protection Yes. Shut-down output and
automatic restart.Short-circuit protection modes Hiccup Mode
Fold BackRestart After Main
Dissipation power load max (W) 11 Over Load protection Yes Over Voltage Output protection Yes (typ. 35 Vdc)Parallel connection Yes, "Easy Parallel"Power Good contact rating (EN60947.4.1): Max. DC1: 30VDC 1S; AC1: 60 VAC 1A Min. 1mA at 5 VDC
Resistive load Min. permissive load
Climatic
Data
Ambient Temperature operation -25 up to +70 °C (>60°derating 2.5% °C)
Ambient Temperature Storage -40 up to +85 °CHumidity at 25 °C, no condensation 95 % to 25 °C
General
Data
Isolation Voltage (In / Out) 3000 VacIsolation Voltage (In / PE) 1605 VacIsolation Voltage (Out / PE) 500 VacProtection Class (EN/IEC 60529) IP 20Reliability: MTBF IEC 61709 > 500.000 hPollution Degree Environment 2Protection class I with PE connectedDimension (w-h-d) 55x110x105 mmWeight 0.50 kg approx.
Terminal
Connections
Solid (mm2)
Stranded (mm2)
AWG
Torque (NM)
Stripped Length:
Input: 0.2-2.5 0.2-2.5 24-14 0.5-0.6 7 mmOutput: 0.2-2.5 0.2-2.5 24-14 0.5-0.6 7 mm
Output derating Curve
Continuous Load
020406080
100120140160
-10 0 10 20 30 40 50 60 70 °C
%
RoHS✔
UL File E308682
2-PH
120Wmax
P19
SSNA
9000
Pow
er
Supp
lies
P
FLEX
Discount Schedule T-6
FLEX17024BInput: two-phase 230 / 400 … 500 V ACOutput: 24 V DC 60ºCEfficiency up to 91%Strong overload without switch-off, up to 50%Flexible power continuity: 120 to 180 W"Power Good" ContactSelectable Protection Mode: Hiccup, Fold back (continuous) & Restart after MainDIN Rail Mountable
Extremely small size Input Data Nominal Input Voltage (2 x Vac)
Manual select Input from 230 to 400-500 230 / 400 … 500 Vac
Input Voltage range (Vac) 187 – 264 (230)330 – 550 (400-500)
Inrush Current (Vn and In Load) I2t ≤ 17 A ≤ 5 msec.Frequency 47 – 63 Hz ±6% Input Current (230/400…500 V AC) 1.5 – 0.8 – 0.7 AInternal Fuse T 4 AExternal Fuse (recommended) 10 A (MCB curve B)
Output Data Output Voltage (Vn) Factory Setting ±3% 24 Vdc Adjustment range (Vadj) 22 – 27 VdcStart up with Strong Load (capacitive load) ≤50.000µFTurn-On delay after applying mains voltage 1 sec. (max)Rated Current at 24 V < 40°C (In) 7.5 A (permanent)Rated Current at 24 V < 50°C (In) 6 A (permanent)Rated Current at 24 V < 60°C (In) 5 A (permanent)Power Boost Current at 24 V 60ºC(In) In (60ºC) x 1.5 ≥ 3 min.Current max. Overload �~= 4Vdc (permanent) Imax = In 60°C x (1.8 - 2.2) Current Short Circuit Icc
Max 2 sec.: Hiccup modePermanent: Fold back (Continuous) mode
16A
Hold-up Time ( min. Vac) 24Vdc 5A Typ. 20 msecResidual Ripple ≤ 80 mVpp
Efficiency ≥ 91 %Over temperature Protection Yes. Shut-down output and
automatic restart.Short-circuit protection modes Hiccup Mode
Fold BackRestart After Main
Dissipation power load max (W) 17Over Load protection Yes Over Voltage Output protection Yes (typ. 35 Vdc)Parallel connection YesPower Good contact rating (EN60947.4.1): Max. DC1: 30VDC 1S; AC1: 60 VAC 1A Min. 1mA at 5 VDC
Resistive load Min. permissive load
Climatic
Data
Ambient Temperature operation -25 up to +70 °C (>60°derating 2.5% °C)
Ambient Temperature Storage -40 up to +85 °CHumidity at 25 °C, no condensation 95 % to 25 °C
General
Data
Isolation Voltage (In / Out) 3000 VacIsolation Voltage (In / PE) 1605 VacIsolation Voltage (Out / PE) 500 VacProtection Class (EN/IEC 60529) IP 20Reliability: MTBF IEC 61709 > 500.000 hPollution Degree Environment 2Protection class I with PE connectedDimension (w-h-d) 55x110x105 mmWeight 0.60 kg approx.
Terminal
Connections
Solid (mm2)
Stranded (mm2)
AWG
Torque (NM)
Stripped Length:
Input: 0.2-2.5 0.2-2.5 24-14 0.5-0.6 7 mmOutput: 0.2-2.5 0.2-2.5 24-14 0.5-0.6 7 mm
Flexible Switching Power SuppliesTechnical Information
Output derating Curve
Continuous Load
020406080
100120140160
-10 0 10 20 30 40 50 60 70 °C
%
Output Voltage vs. Output Current, typ.
16; 00
4
8
12
16
20
24
28
0 5 10 15 20
Load (A)
Out Voltage
RoHS✔
UL File E308682
2-PH
180Wmax
P20
SSNA
9000
Pow
er
Supp
lies
P
FLEX
Discount Schedule T-6
Flexible Switching Power SuppliesTechnical Information
FLEX28024BInput: two-phase 230 / 400 … 500 V ACOutput: 24 V DC 60ºCEfficiency up to 91%Strong overload without switch-off, up to 50%Flexible power continuity: 240 to 336 W"Power Good" ContactSelectable Protection Mode: Hiccup, Fold back (continuous) & Restart after MainDIN Rail MountableExtremely small size
Input Data Nominal Input Voltage (2 x Vac) Manual select Input from 230 to 400-500
230 / 400 … 500 Vac
Input Voltage range (Vac) 187 – 264 (230)330 – 550 (400-500)
Inrush Current (Vn and In Load) I2t ≤ 17 A ≤ 5 msec.Frequency 47 – 63 Hz ±6% Input Current (230/400…500 V AC) 2.2 – 1.4 – 1.0 AInternal Fuse T 4 AExternal Fuse (recommended) 16 A (MCB curve B)
Output Data Output Voltage (Vn) Factory Setting ±3% 24 Vdc Adjustment range (Vadj) 22 – 27 VdcStart up with Strong Load (capacitive load) ≤50.000µFTurn-On delay after applying mains voltage 1 sec. (max)Rated Current at 24 V < 40°C (In) 14 A (permanent)Rated Current at 24 V < 50°C (In) 12 A (permanent)Rated Current at 24 V < 60°C (In) 10 A (permanent)Power Boost Current at 24 V 60ºC(In) In (60ºC) x 1.5 ≥ 3 min.Current max. Overload �~= 4Vdc (permanent) Imax = In 60°C x (1.8 - 2.2) Current Short Circuit Icc
Max 2 sec.: Hiccup modePermanent: Fold back (Continuous) mode
30A
Hold-up Time ( min. Vac) 24Vdc 5A Typ. 20 msecResidual Ripple ≤ 80 mVpp
Efficiency ≥ 91 %Over temperature Protection Yes. Shut-down output and
automatic restart.Short-circuit protection modes Hiccup Mode
Fold BackRestart After Main
Dissipation power load max (W) 28Over Load protection Yes Over Voltage Output protection Yes (typ. 35 Vdc)Parallel connection YesPower Good contact rating (EN60947.4.1): Max. DC1: 30VDC 1S; AC1: 60 VAC 1A Min. 1mA at 5 VDC
Resistive load Min. permissive load
Climatic
Data
Ambient Temperature operation -25 up to +70 °C (>60°derating 2.5% °C)
Ambient Temperature Storage -40 up to +85 °CHumidity at 25 °C, no condensation 95 % to 25 °C
General
Data
Isolation Voltage (In / Out) 3000 VacIsolation Voltage (In / PE) 1605 VacIsolation Voltage (Out / PE) 500 VacProtection Class (EN/IEC 60529) IP 20Reliability: MTBF IEC 61709 > 500.000 hPollution Degree Environment 2Protection class I with PE connectedDimension (w-h-d) 72x115x135 mmWeight 0.65 kg approx.
Terminal
Connections
Solid (mm2)
Stranded (mm2)
AWG
Torque (NM)
Stripped Length:
Input: 0.2-2.5 0.2-2.5 24-14 0.5-0.6 7 mmOutput: 0.2-2.5 0.2-2.5 24-14 0.5-0.6 7 mmSignal: 0.2-2.5 0.2-2.5 24-14 0.5-0.6 7 mm
Output derating Curve
Continuous Load
020
406080
100120
140160
-10 0 10 20 30 40 50 60 70°C
%
Output Voltage vs. Output Current, typ.
0
4
8
12
16
20
24
28
0 10 20 30 40
Load (A)
Out Voltage
RoHS✔
UL File E308682
2-PH
336Wmax
P21
SSNA
9000
Pow
er
Supp
lies
P
FLEX
Discount Schedule T-6
FLEX50024BInput: three-phase 400 … 500 V ACOutput: 24 V DC 60ºCEfficiency up to 92%Strong overload without switch-off, up to 50%Flexible power continuity: 480 to 600 W"Power Good" ContactSelectable Protection Mode: Hiccup, Fold back (continuous) & Restart after MainDIN Rail MountableExtremely small size
Input Data Nominal Input Voltage (3 x Vac) 400…500 VacInput Voltage range (Vac) 330 – 550Inrush Current (Vn and In Load) I2t ≤ 17 A ≤ 5 msec.Frequency 47 – 63 Hz ±6% Input Current (400…500 V AC) 0.95 – 0.85 AInternal Fuse T 6.3 AExternal Fuse (recommended) 16 A (MCB curve B)
Output Data Output Voltage (Vn) Factory Setting ±3% 24 Vdc Adjustment range (Vadj) 22 – 27 VdcStart up with Strong Load (capacitive load) ≤50.000µFTurn-On delay after applying mains voltage 1 sec. (max)Rated Current at 24 V < 40°C (In) 25 A (permanent)Rated Current at 24 V < 50°C (In) 22 A (permanent)Rated Current at 24 V < 60°C (In) 20 A (permanent)Power Boost Current at 24 V 60ºC(In) In (60ºC) x 1.5 ≥ 3 min.Current max. Overload �~= 4Vdc (permanent) Imax = In 60°C x (1.8 - 2.2) Current Short Circuit Icc
Max 2 sec.: Hiccup modePermanent: Fold back (Continuous) mode
60A
Hold-up Time ( min. Vac) 24Vdc 5A Typ. 20 msecResidual Ripple ≤ 80 mVpp
Efficiency ≥ 92 %Over temperature Protection Yes. Shut-down output and
automatic restart.Short-circuit protection modes Hiccup Mode
Fold BackRestart After Main
Dissipation power load max (W) 28Over Load protection Yes Over Voltage Output protection Yes (typ. 35 Vdc)Parallel connection YesPower Good contact rating (EN60947.4.1): Max. DC1: 30VDC 1S; AC1: 60 VAC 1A Min. 1mA at 5 VDC
Resistive load Min. permissive load
Climatic
Data
Ambient Temperature operation -25 up to +70 °C (>60°derating 2.5% °C)
Ambient Temperature Storage -40 up to +85 °CHumidity at 25 °C, no condensation 95 % to 25 °C
General
Data
Isolation Voltage (In / Out) 3000 VacIsolation Voltage (In / PE) 1605 VacIsolation Voltage (Out / PE) 500 VacProtection Class (EN/IEC 60529) IP 20Reliability: MTBF IEC 61709 > 500.000 hPollution Degree Environment 2Protection class I with PE connectedDimension (w-h-d) 85x120x140 mmWeight 0.75 kg approx.
Terminal
Connections
Solid (mm2)
Stranded (mm2)
AWG
Torque (NM)
Stripped Length:
Input: 4.0 6.0 30-10 0.8-1.0 7 mmOutput: 4.0 6.0 30-10 0.8-1.0 7 mmSignal: 0.2-2.5 0.2-2.5 24-14 0.5-0.6 7 mm
Flexible Switching Power SuppliesTechnical Information
RoHS✔
UL File E308682
3-PH
600Wmax
P22
SSNA
9000
Pow
er
Supp
lies
P
FLEX
Discount Schedule T-6
Flexible Switching Power SuppliesTechnical Information
Dimensions
FLEX WIDTH HEIGHT DEPTH
FLEX6024A 50 120 50
FLEX9024A, 17024AFLEX9024B, 17024B
55 110 105
FLEX28024A & B 72 115 135
FLEX50024A & B 85 120 140
Electrical Connection
Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes.
HEIGHT
WIDTH DEPTH
Connection: 1 Phase Models 2 Phase Models 3 Phase Models
Rail Mounting: Assembly Disassemby Maximum angle assembly
Other models / modules must have a minimum vertical and horizontal distance of 10 cm to this power supply in order to guarantee sufficient auto convection. Depending on the ambient temperature and load of the device, the temperature of the housing can become very high!
-5° / +5° max
Easy Parallel connection OFF(factory selection)
Easy Parallel connection ON
Parallel Connection, to Increase Output Power:• Made parallel connection with same model of power supply to
increase the output power.
• Adjust the output approximately to the same value
(± 20mV) applying 1-2 A load to all devices output
before connecting them in parallel.
• Easy parallel connections Jumper. In FLEX280xxX and
FLEX500xxX for more power, you must change position
of the jumper to enable parallel connection. In this mode you can
put in parallel up to 4 power supply
Connection: 1 Phase Models 2 Phase Models 3 Phase Models
Rail Mounting: Assembly Disassemby Maximum angle assembly
Other models / modules must have a minimum vertical and horizontal distance of 10 cm to this power supply in order to guarantee sufficient auto convection. Depending on the ambient temperature and load of the device, the temperature of the housing can become very high!
-5° / +5° max
Easy Parallel connection OFF(factory selection)
Easy Parallel connection ON
Connection: 1 Phase Models 2 Phase Models 3 Phase Models
Rail Mounting: Assembly Disassemby Maximum angle assembly
Other models / modules must have a minimum vertical and horizontal distance of 10 cm to this power supply in order to guarantee sufficient auto convection. Depending on the ambient temperature and load of the device, the temperature of the housing can become very high!
-5° / +5° max
Easy Parallel connection OFF(factory selection)
Easy Parallel connection ON
Connection: 1 Phase Models 2 Phase Models 3 Phase Models
Serial Connection:a) It is possible to connect as many units in series as
needed, pro-
viding the sum
of the output
voltage does
not exceed
150Vdc.
b) Voltages with a potential above 60Vdc are not SELV any
more and can be dangerous. Such voltages must be
installed with a protection against touching.
c) For serial operation use power supplies of the same type.
d) Grounding of the output is required when the sum of the
output voltage is above 60Vdc.
e) Keep an installation clearance of 15mm (left/right)
between two power supplies and avoid installing the
power supplies on top of each other. Note: Avoid return
voltage (e.g. from a decelerating motor or battery) which
is applied to the output terminals.
Connection: 1 Phase Models 2 Phase Models 3 Phase Models
Rail Mounting: Assembly Disassemby Maximum angle assembly
Other models / modules must have a minimum vertical and horizontal distance of 10 cm to this power supply in order to guarantee sufficient auto convection. Depending on the ambient temperature and load of the device, the temperature of the housing can become very high!
-5° / +5° max
Easy Parallel connection OFF(factory selection)
Easy Parallel connection ON
Connection: 1 Phase Models 2 Phase Models 3 Phase Models
Rail Mounting: Assembly Disassemby Maximum angle assembly
Other models / modules must have a minimum vertical and horizontal distance of 10 cm to this power supply in order to guarantee sufficient auto convection. Depending on the ambient temperature and load of the device, the temperature of the housing can become very high!
-5° / +5° max
Easy Parallel connection OFF(factory selection)
Easy Parallel connection ON
P23
SSNA
9000
Pow
er
Supp
lies
P
FLEX
Discount Schedule T-6
Notes
P24
SSNA
9000
Pow
er
Supp
lies
P
FLEX
Discount Schedule T-6
Notes