1
heats circulates stirs pumps BRONWILL CONSTANT TEMPERATURE CIRCULATOR Here's everything you need in one compact unit. Smaller, lighter weight and more accu- rate (to + 0.01°C), this new model instantly converts any suitable container to an effi- cient, closely controlled, con- stant temperature bath or circulating system. Easy to use —easy to store—always ready for the next bath. Like more information? Just drop u s a note and we'll rush complete data. BRONWILL SCIENTIFIC A DIVISION OF WILL SCIENTIFIC, INC. 210 N. GOODMAN ST., ROCHESTER 3, N. Y.| Circle No. 39 on Readers' Service Card NEW PRODUCTS 100 KV X-Ray Spectrograph Design changes on this 100 KV X-Ray Spectrograph include automatic crystal changer with three crystals, "piggy" back arrangement of scintillation and flow proportional counters, and im- proved signal-to-noise ratio for high atomic number elements. "K" line up to Bi (No. 83) can be determined qualitatively; "K" lines up to Sn (No. 50) can be determined quantitatively using voltages three times excitation level. Helium or hydrogen (with safety controls) can be used for the light elements from Ti (No. 22) to Mg (No. 12). The water-cooled x-ray tube has a tungsten or molybdenum target and beryllium window and has a maximum rating of 2.5 KW at 50 ma. for constant potential. Power requirements are 200 volts, 60 cycles, single phase, 25 amperes. Phil- ips Electronic Instruments, 750 S. Ful- ton Ave., Mount Vernon, Ν. Υ. 418 Wide-Band D-C Amplifier Signal amplifications over a wide band with low phase or amplitude dis- tortion are available with a direct coupled amplifier designed for appli- cations requiring amplification of fast pulses, sine waves, ramp voltages, or other wave forms. Driven by a single- phase input signal, the amplifier will provide two output signals in comple- mentary phase, the principle output being in phase with the input, with a gain of 10 for each phase and a push- pull signal amplitude of 100 volts peak-to-peak. Nonlinearity is less than 2%. Both output signals can be adjusted to have their quiescent level at ground potential, and either may be used alone to obtain a ground-refer- enced signal of 50 volts peak-to-peak amplitude. Rise and fall times for the amplifier are less than 0.06 micro- second at full output amplitude. Bull. No. 43-562. Elcor, Inc., 1225 W. Broad St., Falls Church, Va. 419 Accurate Micro-Feeder Plunger pump delivers an absolutely uniform pulsationless flow, at controlled rate (from 1.0 cc. to 800 cc./hr., inde- pendent of variations in feed pressure, viscosity, or vapor pressure of the liquid and with an accuracy within ±0.25% (assuming close temperature control). The Micro-Feeder is used for catalyst charge testing in petroleum laboratories or feeding additives to a main stream. Data sheet available. B-I-F Industries, P.O. Box 276, Providence 1, R. I. 420 INDICATE and TRANSMIT .. .to existing potentiometer recorders with a single, inexpensive SOLU METER FOR LABOR A TORY AND PLANT CONDUCTIVITY MEASUREMENTS The RA-4 SOLU METER® provides direct meter display of solution conductivity economically, in the laboratory or on the process line. Check these superior features: • Scales may be linear or non-linear and are available in a wide selection of ranges. • Manual or automatic temperature compensators. • Portable or panel mounting. • Wide choice of conductivity cells. • Overall 2% full scale accuracy; adjustment permits closer readings. • 0-10 mv DC output operates standard recorders. • Simple to calibrate; can be operated by untrained personnel if required. Price only $186.00 f.o.b. Cedar Grove, N. J. We invite your inquiry. Industrial Instruments INC 89 Commerce Road, Cedar Grove, Essex County, New iersey VISIT US AT ISA'ISHOW BOOTHS 2E5-Z27 Circle No. 59 on Readers' Service Card 124 A · ANALYTICAL CHEMISTRY

Industrial Instruments

  • Upload
    doanh

  • View
    217

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Industrial Instruments

heats circulates

stirs pumps

BRONWILL CONSTANT

TEMPERATURE CIRCULATOR

Here's everything you need in one compact unit. Smaller, lighter weight and more accu­rate (to + 0.01°C), this new model instantly converts any suitable container to an effi­cient, closely controlled, con­s tant temperature ba th or circulating system. Easy to use —easy to store—always ready for the next bath . Like more information? Jus t drop us a note and we'll rush complete data.

BRONWILL SCIENTIFIC

A DIVISION OF WILL SCIENTIFIC, INC.

2 1 0 N. GOODMAN ST., ROCHESTER 3 , N. Y.| Circle No. 39 on Readers' Service Card

NEW PRODUCTS

100 KV X-Ray Spectrograph

Design changes on this 100 KV X-Ray Spectrograph include automatic crystal changer with three crystals, "piggy" back arrangement of scintillation and flow proportional counters, and im­proved signal-to-noise ratio for high atomic number elements. "K" line up to Bi (No. 83) can be determined qualitatively; "K" lines up to Sn (No. 50) can be determined quantitatively using voltages three times excitation level. Helium or hydrogen (with safety controls) can be used for the light elements from Ti (No. 22) to Mg (No. 12).

The water-cooled x-ray tube has a tungsten or molybdenum target and beryllium window and has a maximum rating of 2.5 KW at 50 ma. for constant potential.

Power requirements are 200 volts, 60 cycles, single phase, 25 amperes. Phil­ips Electronic Instruments, 750 S. Ful­ton Ave., Mount Vernon, Ν. Υ. 418

Wide-Band D-C Amplifier Signal amplifications over a wide

band with low phase or amplitude dis­tortion are available with a direct coupled amplifier designed for appli­cations requiring amplification of fast pulses, sine waves, ramp voltages, or other wave forms. Driven by a single-phase input signal, the amplifier will provide two output signals in comple­mentary phase, the principle output being in phase with the input, with a gain of 10 for each phase and a push-pull signal amplitude of 100 volts peak-to-peak. Nonlinearity is less than 2%. Both output signals can be adjusted to have their quiescent level at ground potential, and either may be used alone to obtain a ground-refer­enced signal of 50 volts peak-to-peak amplitude. Rise and fall times for the amplifier are less than 0.06 micro­second at full output amplitude. Bull. No. 43-562. Elcor, Inc., 1225 W. Broad St., Falls Church, Va. 419

Accurate Micro-Feeder Plunger pump delivers an absolutely

uniform pulsationless flow, at controlled rate (from 1.0 cc. to 800 cc./hr., inde­pendent of variations in feed pressure, viscosity, or vapor pressure of the liquid and with an accuracy within ±0.25% (assuming close temperature control). The Micro-Feeder is used for catalyst charge testing in petroleum laboratories or feeding additives to a main stream. Data sheet available. B-I-F Industries, P.O. Box 276, Providence 1, R. I. 420

INDICATE and TRANSMIT

.. .to existing potentiometer recorders with a single, inexpensive

SOLU METER

FOR LABOR A TORY AND PLANT CONDUCTIVITY MEASUREMENTS

The RA-4 SOLU METER® provides direct meter display of solution conductivity economically, in the laboratory or on the process line. Check these superior features:

• Scales may be linear or non-linear and are available in a wide selection of ranges.

• Manual or automatic temperature compensators.

• Portable or panel mounting.

• Wide choice of conductivity cells. • Overall 2% full scale accuracy;

adjustment permits closer readings. • 0-10 mv DC output operates standard

recorders. • Simple to calibrate; can be operated

by untrained personnel if required.

Price only $186.00 f.o.b. Cedar Grove, N. J.

We invite your inquiry.

Industrial Instruments INC

89 Commerce Road, Cedar Grove, Essex County, New iersey VISIT US AT ISA'ISHOW BOOTHS 2E5-Z27

Circle No. 59 on Readers' Service Card

1 2 4 A · ANALYTICAL CHEMISTRY