DESCRIPTION During the system operation, the pressure drop through the filter increases as the element clogs, due to the contaminant retained. The filter element must be replaced when clogged and anyway before the pressure drop reaches the bypass valve set value. For this reason it is recommended a clogging indicator on the filter. It gives a visual or electrical indication and must have a set value lower than the bypass valve set value, to get an exact indication of the right time for filter element replacement. On return and low pressure filters the clogging indicator can be a pressure gauge or a pressure switch, measuring the pressure upstream the filter. On some return filters and on high pressure filters, the clogging indicator can be of differential type: measuring the pressure upstream and downstream the filter and activating a signal when the differential pressure reaches the set value. On suction filters the clogging indicator is a vacuum gauge or a vacuum switch, measuring the depressure downstream the filter. All the UFI filters have the port for the indicator as a standard feature; if the filter is ordered without indicator the port is plugged with a removeable plug allowing the indicator to be added easily at any time. Pressure gauges Pressure switches Differential, visual Differential, electrical Differential, el. + LED Differential, el. + thermostat Differential, el. + visual Differential, el. ATEX RETURN FILTERS INDICATORS Pressure gauges Pressure switches Differential, visual Differential, electrical Differential, el. + LED Differential, el. + thermostat Differential, el. + visual Differential, el. Vandal proof Differential, el. ATEX PRESSURE FILTERS INDICATORS CLOGGING INDICATORS SUMMING-UP Vacuum gauges Vacuum switches SUCTION FILTERS INDICATORS Differential, visual Differential, electrical Differential, el. + LED Differential, el. + thermostat Differential, el. + visual Differential, el. ATEX OFF-LINE FILTERS INDICATORS

INDICATORS - بنیان تدبیر پارس sw.pdf · 2018. 12. 9. · NBR FKM 70 Setting 1,3 bar (130 kPa) RF Differential VISUAL ELECTRICAL indicators E0 71 E1 Setting 2 bar (200

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: INDICATORS - بنیان تدبیر پارس sw.pdf · 2018. 12. 9. · NBR FKM 70 Setting 1,3 bar (130 kPa) RF Differential VISUAL ELECTRICAL indicators E0 71 E1 Setting 2 bar (200

DESCRIPTION

During the system operation, the pressure drop through the fi lter increases as the element clogs, due to the contaminant retained.The fi lter element must be replaced when clogged and anyway before the pressure drop reaches the bypass valve set value.For this reason it is recommended a clogging indicator on the fi lter. It gives a visual or electrical indication and must have a set value lower than the bypass valve set value, to get an exact indication of the right time for fi lter element replacement.

On return and low pressure fi lters the clogging indicator can be a pressure gauge or a pressure switch, measuring the pressure upstream the fi lter. On some return fi lters and on high pressure fi lters, the clogging indicator can be of differential type: measuring the pressure upstream and downstream the fi lter and activating a signal when the differential pressure reaches the set value.On suction fi lters the clogging indicator is a vacuum gauge or a vacuum switch, measuring the depressure downstream the fi lter.All the UFI fi lters have the port for the indicator as a standard feature; if the fi lter is ordered without indicator the port is plugged with a removeable plug allowing the indicator to be added easily at any time.

Pressure gaugesPressure switchesDifferential, visualDifferential, electricalDifferential, el. + LEDDifferential, el. + thermostatDifferential, el. + visualDifferential, el. ATEX

RETURN FILTERS INDICATORS

Pressure gaugesPressure switchesDifferential, visualDifferential, electricalDifferential, el. + LEDDifferential, el. + thermostatDifferential, el. + visualDifferential, el. Vandal proofDifferential, el. ATEX

PRESSURE FILTERS INDICATORS

CLOGGINGINDICATORS

S U M M I N G - U P

Vacuum gaugesVacuum switches

SUCTION FILTERS INDICATORS

Differential, visualDifferential, electricalDifferential, el. + LEDDifferential, el. + thermostatDifferential, el. + visualDifferential, el. ATEX

OFF-LINE FILTERS INDICATORS

Page 2: INDICATORS - بنیان تدبیر پارس sw.pdf · 2018. 12. 9. · NBR FKM 70 Setting 1,3 bar (130 kPa) RF Differential VISUAL ELECTRICAL indicators E0 71 E1 Setting 2 bar (200

PRESSURE INDICATION DIFFERENTIAL PRESSURE INDICATION

INDICATOR SERIES DESCRIPTION FOR PRESSURE FILTERS SERIES

NBR FKM

31 PE - PHScale 0÷12 bar (0÷1,2 MPa)-

ø 40

1/8”

31

12Pressure gauge

NBR FKM

U0 for FPE A+, B+Setting 1,3 bar (130 kPa)W0

32 20

M14

Differential VISUAL indicator

Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

35,5

30

ø 30

M20 x 1,5

NBR FKM

5B PHSetting 1,3 bar (130 kPa)

Differential VISUAL indicators

AB

5D (PA - PB - PD - PL - PM)Setting 2,5 bar (250 kPa)AD

5E PA - PB - PC - PD - PL - PM

PA - PB - PC - PD - PL - PM

Setting 5 bar (500 kPa)AE

5F Setting 8 bar (800 kPa)AF Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

NBR FKM

N0 for FPE A+, B+Setting 1,3 bar (130 kPa)S0N.C.N.O.

63,5

35

27

M14

Differential VISUAL ELECTRICAL indicator

Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650

INDICATORS FOR PRESSURE FILTERS

PA - PB - PC - PD - PL - PM

PA - PB - PC - PD - PL - PM

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650

NBR FKM

6B PHSetting 1,3 bar (130 kPa)

Differential ELECTRICAL indicators

CB

6D (PA - PB - PD - PL - PM)Setting 2,5 bar (250 kPa)CD

6E Setting 5 bar (500 kPa)CE

6F Setting 8 bar (800 kPa)CF

N.C.N.O.

64,5

30

4835

M20 x 1,5Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

NBR FKM

P1 PE - PHSetting 1,5 bar (150 kPa)-1

4 2

Pressure switch

SPDT, Max voltage 250V - 50 Hz - Max current 6 A resistive, 1 A inductive - Protection IP65 connector DIN 43650

ATEX 3 GD EEx e T6

977

1/8”

24

Page 3: INDICATORS - بنیان تدبیر پارس sw.pdf · 2018. 12. 9. · NBR FKM 70 Setting 1,3 bar (130 kPa) RF Differential VISUAL ELECTRICAL indicators E0 71 E1 Setting 2 bar (200

CLOGGING INDICATORSS U M M I N G U P

PA - PB - PC - PD - PL - PM

PA - PB - PC - PD - PL - PM

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650

NBR FKM

70 PHSetting 1,3 bar (130 kPa)

Differential VISUAL ELECTRICAL indicators

E0

76 Setting 2,5 bar (250 kPa)E6

72 Setting 5 bar (500 kPa)E2

73 Setting 8 bar (800 kPa)E3

70

48

30M20 x 1,5

O

30°C

O(PA - PB - PD - PL - PM)

Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

PA - PB - PC - PD - PL - PM

PA - PB - PC - PD - PL - PM

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650

NBR FKM

T0 PHSetting 1,3 bar (130 kPa)

Differential ELECTRICAL indicators with THERMOSTAT 30° C

DB

T2 Setting 5 bar (500 kPa)DE

T3 Setting 8 bar (800 kPa)DF

T6 Setting 2,5 bar (250 kPa)DD70

59

32

M20 x 1,5

O

30°C

O

(PA - PB - PD - PL - PM)

Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

PA - PB - PC - PD - PL - PM

PA - PB - PC - PD - PL - PM

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650

G R231+

4-

N.C.N.O.C

NBR FKM

7B PHSetting 1,3 bar (130 kPa)

Differential ELECTRICAL indicators with LED (24 V) for visual indication

EB

7D Setting 2,5 bar (250 kPa)ED

7E Setting 5 bar (500 kPa)EE

7F Setting 8 bar (800 kPa)EF

64,5

30

4835

M20 x 1,5

(PA - PB - PD - PL - PM)

Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

NBR FKM

008.0240.2

008.0239.2Setting 2,5 bar (250 kPa)

Setting 1,3 bar (130 kPa)

Differential ELECTRICAL indicators ATEX

-

-

008.0235.2 Setting 5 bar (500 kPa)-

008.0212.2 Setting 8 bar (800 kPa)-

N.C.N.O.

5631

24

27

ø 27,5

35

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 M20x1,5

PA - PB - PC - PD - PL - PM

PA - PB - PC - PD - PL - PM

PA - PB - PD - PL - PM

(PA - PB - PD - PL - PM)

Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

ATEX 3 GD EEx e T6

INDICATOR SERIES DESCRIPTION FOR PRESSURE FILTERS SERIES

NBR FKM

M2 Setting 5 bar (500 kPa)

Differential ELECTRICAL indicators VANDAL PROOF

-

M3 Setting 8 bar (800 kPa)-

M6 Setting 2,5 bar (250 kPa)- 5076

REED SWITCH

32

98

106

M20

x1,5

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650

PA - PB - PC - PD - PL - PM

PA - PB - PC - PD - PL - PM

(PA - PB - PD - PL - PM)

Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

NO

Page 4: INDICATORS - بنیان تدبیر پارس sw.pdf · 2018. 12. 9. · NBR FKM 70 Setting 1,3 bar (130 kPa) RF Differential VISUAL ELECTRICAL indicators E0 71 E1 Setting 2 bar (200

PRESSURE INDICATION DIFFERENTIAL PRESSURE INDICATION

INDICATORS FOR RETURN FILTERS

NBR FKM

6B RFSetting 1,3 bar (130 kPa)

Differential ELECTRICAL indicators

CB

6C RDSetting 2 bar (200 kPa)CC

N.C.N.O.64

,5

30

4835

M20 x 1,5SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Re

com

men

ded

tight

enin

g to

rque

90

Nm

NBR FKM

32 RA - RB - RC - RF - RHScale 0÷6 bar (0÷600 kPa)-

ø 40 30

1/8”

Pressure gauge

35,5

30

ø 30

M20 x 1,5

NBR FKM

5B RFSetting 1,3 bar (130 kPa)

Differential VISUAL indicators

AB

5C RDSetting 2 bar (200 kPa)AC

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Re

com

men

ded

tight

enin

g to

rque

90

Nm

INDICATOR SERIES DESCRIPTION FOR RETURN FILTERS SERIES

NBR FKM

30 RA - RB - RC - RF - RHScale 0÷6 bar (0÷600 kPa)-

ø 40

1/8”

31

12

Pressure gauge

NBR FKM

P1 RA - RB - RC - RHSetting 1,5 bar (150 kPa) - SPDT

Pressure switch

-

P2 RF - W executionSetting 3 bar (300 kPa) - SPDT-

P4 RFSetting 1,3 bar (130 kPa) - SPDT-

P6 RBSetting 2 bar (200 kPa) - SPDT-

1

4 2

SPDT, Max voltage 250V - 50 Hz - Max current 6 A resistive, 1 A inductive - Protection IP65 connector DIN 43650

ATEX 3 GD EEx e T6

977

1/8”

24

Page 5: INDICATORS - بنیان تدبیر پارس sw.pdf · 2018. 12. 9. · NBR FKM 70 Setting 1,3 bar (130 kPa) RF Differential VISUAL ELECTRICAL indicators E0 71 E1 Setting 2 bar (200

S U M M I N G U P

G R231+

4-

N.C.N.O.C

NBR FKM

7B RFSetting 1,3 bar (130 kPa)

Differential ELECTRICAL indicators with LED (24 V) for visual indication

EB

7C RDSetting 2 bar (200 kPa)EC

64,5

30

4835

M20 x 1,5SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650

Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

NBR FKM

70 RFSetting 1,3 bar (130 kPa)

Differential VISUAL ELECTRICAL indicators

E0

71 RDSetting 2 bar (200 kPa)E1

70

48

30M20 x 1,5

O

30°C

O

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650

Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

NBR FKM

008.0234.2

008.0239.2

RD

RF

Setting 2 bar (200 kPa)

Setting 1,3 bar (130 kPa)

Differential ELECTRICAL indicators ATEX

-

-N.C.N.O.

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650

5631

24

27

ø 27,5

35

M20x1,5Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

ATEX 3 GD EEx e T6

INDICATOR SERIES DESCRIPTION FOR RETURN FILTERS SERIES

CLOGGING INDICATORS

NBR FKM

T0 RFSetting 1,3 bar (130 kPa)

Differential ELECTRICAL indicators with THERMOSTAT 30° C

DB

T1 RDSetting 2 bar (200 kPa)DC70

59

32

M20 x 1,5SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Re

com

men

ded

tight

enin

g to

rque

90

Nm

O

30°C

O

Page 6: INDICATORS - بنیان تدبیر پارس sw.pdf · 2018. 12. 9. · NBR FKM 70 Setting 1,3 bar (130 kPa) RF Differential VISUAL ELECTRICAL indicators E0 71 E1 Setting 2 bar (200

PRESSURE INDICATION DIFFERENTIAL PRESSURE INDICATION

35,5

30

ø 30

M20 x 1,5

NBR FKM

5B OF - UOWSetting 1,3 bar (130 kPa)

Differential VISUAL indicators

AB

INDICATORS FOR OFF-LINE FILTERS

INDICATOR SERIES DESCRIPTION FOR RETURN OFF-LINE SERIES

NBR FKM

008.0239.2 OF - UOWSetting 1,3 bar (130 kPa)

Differential ELECTRICAL indicators ATEX

-

N.C.N.O.

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650

NBR FKM

70 OF - UOWSetting 1,3 bar (130 kPa)

Differential VISUAL ELECTRICAL indicators

E0

70

48

30M20 x 1,5

O

30°C

O

SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650

NBR FKM

T0 OF - UOWSetting 1,3 bar (130 kPa)

Differential ELECTRICAL indicators with THERMOSTAT 30° C

DB

70

59

32

M20 x 1,5SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650

G R231+

4-

N.C.N.O.C

NBR FKM

7B OF - UOWSetting 1,3 bar (130 kPa)

Differential ELECTRICAL indicators with LED (24 V) for visual indication

EB

64,5

30

4835

M20 x 1,5SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650

NBR FKM

6B OF - UOWSetting 1,3 bar (130 kPa)

Differential ELECTRICAL indicators

CBN.C.N.O.

64,5

30

4835

M20 x 1,5SPDT differential switch. C.C. 14 - 30 V: > max resistive or inductive load 4 - 3 A respectivelyC.A. 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650

5631

24

27

ø 27,5

35

M20x1,5

Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

Reco

mm

ende

d tig

hten

ing

torq

ue 9

0 Nm

ATEX 3 GD EEx e T6

O

30°C

O

Page 7: INDICATORS - بنیان تدبیر پارس sw.pdf · 2018. 12. 9. · NBR FKM 70 Setting 1,3 bar (130 kPa) RF Differential VISUAL ELECTRICAL indicators E0 71 E1 Setting 2 bar (200

ø 40

31

1/8”

12

NBR FKM

10 SC - SD - SEVacuum gauge-

NBR FKM

11 SC - SD Vacuum gauge-

ø 40

1/8”

30

NBR FKM

91 SC - SD - SE Vacuum switchSetting 0,2 bar (20 kPa)SPDT

-

Tech

nica

l dat

a su

bjec

t to

varia

tions

with

out p

rior n

otic

e.

IND

ICAT

OR

S -

EN

- 02

/201

6

INDICATORS FOR SUCTION FILTERS

INDICATOR SERIES DESCRIPTION FOR SUCTION FILTERS SERIES

S U M M I N G U P

SPDT, Max voltage 250V - 50 Hz - Max current 6 A resistive, 1 A inductive - Protection IP65 connector DIN 43650

ATEX 3 GD EEx e T6

977

1/8”

24

CLOGGING INDICATORS

Is this datasheet the latest release?

Please check on our website.

1

23