Incremental linear encodersbased on the inductive AMOSIN® Measuring Principle
August 2016Product information
2
LMK-2010 series• Composed of AK LMK-2010 and measuring scale• Grating period 1000µm• Encoder with integrated electronics
Design 20with measuring scale LMB-110
Tolerance priciple in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
Tolerierungsgrundsatz nach ISO 8015Allgemeintoleranz nach ISO 2768-fHAlle Maße in mm
H1 = Air gap 0,15 ± 0,10mm, set with spacer foilH2 = Reference track markingH3 = Direction of scanning head movement for positive countingH4 = Ground plane
3 ±
0,5
10
H2
4,
5
49
61
73
3,5
4,5
19
22,
5
7,4
5
0,8
H4
H1
29
3,5
16
H3
1 ±
0,5
4,
5
49
61
73
3,5
4,5
19
5,1
22,
5
11,
8
H4
H1
29
3,5
16
14
H3
H2
Design 20with measuring scale LMB-410
Tolerance principle in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
3
LMK-2010 series• Composed of AK LMK-2010 and measuring scale• Grating period 1000µm• Encoder with integrated electronics
Design 21with measuring scale LMB-110
36 = =
2,5
2x 4
10
H2
4,
5
49 ~10,5
H1
13,
2
13,
5
30
3 ±0,5
H3
26 = =
4,8
2x M3 0,8
Tolerance priciple in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
Tolerierungsgrundsatz nach ISO 8015Allgemeintoleranz nach ISO 2768-fHAlle Maße in mm
36 = =
2,5
2x 4
H2
4,
5
49 ~10,5
5,1
H1
13,
2
13,
5
30
1 ±0,5
14 H3
26 = =
9,1
2x M3
Design 21with measuring scale LMB-410F
H1 = Air gap 0,15 ± 0,10mm, set with spacer foilH2 = Reference track markingH3 = Direction of scanning head movement for positive counting
Tolerance principle in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
4
LMK-1010 series• Composed of AK LMK-1010 and measuring scale
• Grating period 1000µm
• Miniature encoder with external electronics
Tolerance priciple in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
Tolerierungsgrundsatz nach ISO 8015Allgemeintoleranz nach ISO 2768-fHAlle Maße in mm
Design 10 and 12with measuring scale LMB-100
10
H2
4,
5 ~9 16 = =
35,5
2x 3,5
9,9
5
0,8
H4
H1
12
1 ±0,5
12
H3
H2
2x 3,5
4,
5 ~9 = = 16
35,5
14,
27
H4
H1
5,1
14
1 ±0,5
12
12
H3
Design 10 and 12with measuring scale LMB-400
H1 = Air gap 0,15 ± 0,10mm, set with spacer foilH2 = Reference track markingH3 = Direction of scanning head movement for positive countingH4 = Ground plane (both sides)
Tolerance principle in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
5
Scanning head 1000µm
LMK-2010, LMK-1010
Performance Standard High Accuracy
Interface 1Vpp TTL 1Vpp TTL
Position error per grating period ± 2µm ± 0,5µm
Maximum speed 20m/s
TTL - interpolation/ 1Vpp signal period
Signal period 1)
Interpolation--
250µm to 1µm1 to 250
--
0,5µm or 0,1µm500 or 2500
Signal period Dividing factor
1000µm or 40µm1 or 25
--
20µm50
--
Max. output frequency 400KHz 5MHz 400KHz 5MHz
Electrical connection Cable with M23 coupling 12pin male
Cable length on the encoder 0,50m - 6,00m
Power supply 1Vpp: DC 4,0V to 7,0VTTL: DC 5,0V +/- 0,5V
Power consumption Design 20, 21: ≤ 1300mW at 5VDesign 10,12: ≤ 1500mW at 5V
Typ. current consumption Design 20, 21: ≤ 220mA at 5V (without load)Design 10,12: ≤ 240mA at 5V (without load)
Vibration < 200m/s² for 55 - 2000Hz
Shock < 2000 m/s2 for 6ms
Operating temperature -10°C to 100°C
Storage temperature -20°C to 100°C
Protection IP67
Weight 38g design 20, 21 / 10g design 10,12
Technical dataLMK - Scanning head for exposed linear encodersGrating period 1000µm
1) After 4-edge-evaluation.
6
Ordering codeLMK - Scanning head for exposed linear encodersGrating period 1000µm
- , - -10 . -LMK-
Scanning
10 = Encoder miniature20 = Encoder with integrated electronics
Reference mark
RV = Rectangle pulse linked (90° el) / for TTL RI = Rectangle pulse linked (360° el) / for 1Vpp
Pin configuration
UJ = 01, 02S12, 03S12, 27S12J5 = 16S15
Electrical connection
01 = Free cable end02S12 = M23-12 pin connector male03S12 = M23-12 pin coupling male16S15 = D-Sub-15 pin 2-row male27S121) = Flange socked M23 12pin male
Cable length
0,50 = 0,50m1,00 = 1,00m1,50 = 1,50m2,00 = 2,00m2,50 = 2,50m3,00 = 3,00m4,00 = 4,00m5,00 = 5,00m6,00 = 6,00m
Performance
S = StandardHA = High Accuracy
Interface
07 = TTL08 = 1Vpp
Functional safety.. = NoFA = Analog signal (1Vpp) can be used for safety related equipment 2)
Interpolation/ Dividing factor1Vpp TTL
S HA S HA
01 1-fold × ×
05 5-fold ×
10 10-fold ×
25 25-fold × ×
50 50-fold × ×
A3 250-fold x
A4 500-fold ×
A9 2500-fold ×
1) Electrical connection for miniaturized design of the scanning head 10 and 12.2) Option „FA“ only used for dividing factor „01“.
Design of the scanning head
10 = Miniaturized, connector with electronics on cable, output M2312 = Miniaturized, pluggable connector with electronics on cable via M12 connector
20 = Standard21 = Standard, flat
7
LMK-2005 series• Composed of AK LMK-2005 and measuring scale
• Grating period 500µm
• Encoder with integrated electronics
Tolerance priciple in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
Tolerierungsgrundsatz nach ISO 8015Allgemeintoleranz nach ISO 2768-fHAlle Maße in mm
Design 20with measuring scale LMB-1150
3 ±
0,3
10
H2
4,
5
49
61
73
3,5
4,5
19
22,
5
7,2
0,6
H4
H1
29
3,5
16
H3 1
±0,
3
4,5
49
61
73
3,5
4,5
19
5,1
22,
5
11,
75
H4
H1
29
3,5
16
14
H3
H2
Design 20with measuring scale LMB-4150
H1 = Air gap 0,10 ± 0,05mm, set with spacer foilH2 = Reference track markingH3 = Direction of scanning head movement for positive countingH4 = Ground plane
Tolerance principle in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
8
Design 21with measuring scale LMB-1150
36 = =
2,5
2x 4
10
H2
4,
5
49 ~10,5
H1
13,
2
13,
5
30
3 ±0,5
H3
26 = =
4,8
2x M3 0,8
LMK-2005 series• Composed of AK LMK-2005 and measuring scale
• Grating period 500µm
• Encoder with integrated electronics
Tolerance priciple in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
Tolerierungsgrundsatz nach ISO 8015Allgemeintoleranz nach ISO 2768-fHAlle Maße in mm
36 = =
2,5
2x 4
H2
4,
5
49 ~10,5
5,1
H1
13,
2
13,
5
30
1 ±0,3
14
H3
26 = =
9,1
2x M3
Design 21with measuring scale LMB-4150F
H1 = Air gap 0,10 ± 0,05mm, set with spacer foilH2 = Reference track markingH3 = Direction of scanning head movement for positive counting
Tolerance principle in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
9
LMK-1005 series• Composed of AK LMK-1005 and measuring scale
• Grating period 500µm
• Miniature encoder with external electronics
Tolerance priciple in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
Tolerierungsgrundsatz nach ISO 8015Allgemeintoleranz nach ISO 2768-fHAlle Maße in mm
Design 10 and 12with measuring scale LMB-1050
10
H2
4,
5 ~9 16 = =
35,5
2x 3,5
9,9
5
0,8
H4
H1
12
1 ±0,5
12
H3
Design 10 and 12with measuring scale LMB-4050
H2
2x 3,5
4,
5 ~9 = = 16
35,5
14,
22
H4
H1
5,1
14
1 ±0,3
12
12
H3
H1 = Air gap 0,10 ± 0,05mm, set with spacer foilH2 = Reference track markingH3 = Direction of scanning head movement for positive countingH4 = Ground plane (both sides)
Tolerance principle in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
10
Scanning head 500µm
LMK-2005, LMK-1005
Performance Standard High Accuracy
Interface 1Vpp TTL 1Vpp TTL
Position error per grating period ± 1,5µm ± 0,3µm
Maximum speed 10m/s
TTL - interpolation/ 1Vpp signal period
Signal period 1)
Interpolation--
125µm to 0,5µm1 to 250
--
0,25µm or 0,05µm500 or 2500
Signal period Dividing factor
500µm or 20µm1 or 25
--
10µm50
--
Max. output frequency 400KHz 5MHz 400KHz 5MHz
Electrical connection Cable with M23 coupling 12pin male
Cable length on the encoder 0,50m - 6,00m
Power supply 1Vpp: DC 4,0V to 7,0VTTL: DC 5,0V +/- 0,5V
Power consumption Design 20, 21: ≤ 1300mW at 5VDesign 10,12: ≤ 1500mW at 5V
Typ. current consumption Design 20, 21: ≤ 220mA at 5V (without load)Design 10,12: ≤ 240mA at 5V (without load)
Vibration < 200m/s² for 55 - 2000Hz
Shock < 2000 m/s2 for 6ms
Operating temperature -10°C to 100°C
Storage temperature -20°C to 100°C
Protection IP67
Weight 38g design 20, 21 / 10g design 10,12
Technical data LMK - Scanning head for exposed linear encodersGrating period 500µm
1) After 4-edge-evaluation.
11
Ordering codeLMK - Scanning head for exposed linear encodersGrating period 500µm
Interpolation/ Dividing factor
1Vpp TTL
S HA S HA
01 1-fold × ×
05 5-fold ×
10 10-fold ×
25 25-fold × ×
50 50-fold × ×
A3 250-fold x
A4 500-fold ×
A9 2500-fold ×
- , - -05 . -LMK-
Scanning
10 = Encoder miniature20 = Encoder with integrated electronics
Reference mark
RV = Rectangle pulse linked (90° el) / for TTL RI = Rectangle pulse linked (360° el) / for 1Vpp
Pin configuration
UJ = 01, 02S12, 03S12, 27S12J5 = 16S15
Electrical connection
01 = Free cable end02S12 = M23-12 pin connector male03S12 = M23-12 pin coupling male16S15 = D-Sub-15 pin 2-row male27S121) = Flange socked M23 12pin male
Cable length
0,50 = 0,50m1,00 = 1,00m1,50 = 1,50m2,00 = 2,00m2,50 = 2,50m3,00 = 3,00m4,00 = 4,00m5,00 = 5,00m6,00 = 6,00m
Design of the scanning head
10 = Miniaturized, connector with electronics on cable, output M2312 = Miniaturized, pluggable connector with electronics on cable via M12 connector
20 = Standard21 = Standard, flat
Performance
S = StandardHA = High Accuracy
Interface
07 = TTL08 = 1Vpp
Functional safety.. = NoFA = Analog signal (1Vpp) can be used for safety related equipment 2)
1) Electrical connection for miniaturized design of the scanning head 10 and 12.2) Option „FA“ only used for dividing factor „01“.
12
LMK-2030 series• Composed of AK LMK-2030 and measuring scale
• Grating period 3000µm
• Encoder with integrated electronics
Design 20with measuring scale LMB-130
1 ±
1
H2
4,
5
49
61
73
3,5
4,5
19
22,
5
0,8
7,7
H4
H1
29
3-3,5
16
14
H3
Tolerance priciple in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
Tolerierungsgrundsatz nach ISO 8015Allgemeintoleranz nach ISO 2768-fHAlle Maße in mm
Design 20with measuring scale LMB-430
H2
4,
5
49
61
73
3,5
4,5
19
5,1
22,
5
12
H4
H1
29
3-3,5
16
18
1 ±0,1
H3
H1 = Air gap 0,40 ± 0,20mm, set with spacer foilH2 = Reference track markingH3 = Direction of scanning head movement for positive countingH4 = Ground plane
Tolerance principle in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
13
LMK-2030 series• Composed of AK LMK-2030 and measuring scale
• Grating period 3000µm
• Encoder with integrated electronics
Tolerance priciple in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
Tolerierungsgrundsatz nach ISO 8015Allgemeintoleranz nach ISO 2768-fHAlle Maße in mm
Design 21with measuring scale LMB-130
36 = =
2,5
2x 4
14
H2
4,
5
49 ~10,5
H1
13,
2
13,
5
30
2 ±1
H3
26 = =
5,0
5
2x M3
0,8
36 = =
2,5
2x 4
H2
4,
5
49 ~10,5
5,1
H1
13,
2
13,
5
30
12 ±1 18
H3
26 = =
9,4
2x M3
Design 21with measuring scale LMB-430F
H1 = Air gap 0,40 ± 0,20mm, set with spacer foilH2 = Reference track markingH3 = Direction of scanning head movement for positive counting
Tolerance principle in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
14
Technical dataLMK - Scanning head for exposed linear encoders Grating period 3000µm
Scanning head3000 µm
LMK-2030
Performance Standard
Interface 1Vpp TTL
Position error per grating period ± 4,0µm
Maximum speed 60m/s
TTL - interpolation/ 1Vpp signal period
Signal period 1)
Interpolation--
750µm to 3µm1 to 250
Signal period Dividing factor
3000µm or 120µm1 or 25
--
Max. output frequency 400KHz 5MHz
Electrical connection Cable with M23 coupling 12pin male
Cable length on the encoder 0,50m - 6,00m
Power supply 1Vpp: DC 4,0V bis 7,0VTTL: DC 5,0V +/- 0,5V
Power consumption Design 20,21: ≤ 1300mW at 5V
Typ. current consumption Design 20,21: ≤ 220mA at 5V (without load)
Vibration < 400m/s² for 55 - 2000Hz
Shock < 2000 m/s2 for 6ms
Operating temperature -10°C to 100°C
Storage temperature -20°C to 100°C
Protection IP67
Weight 38g design: 20, 21
1) After 4-edge-evaluation.
15
Ordering codeLMK - Scanning head for exposed linear encoders Grating period 3000µm
Interpolation/ Dividing factor
1Vpp TTL
S S
01 1-fold ×
05 5-fold ×
10 10-fold ×
25 25-fold × ×
50 50-fold ×
A3 250-fold x
Reference mark
RV = Rectangle pulse linked (90° el) /for TTLRI = Rectangle pulse linked (360° el) /for 1Vpp
Pin configuration
UJ = 01, 02S12, 03S12, 27S12J5 = 16S15
Electrical connection
01 = Free cable end02S12 = M23-12 pin connector male03S12 = M23-12 pin coupling male16S15 = D-Sub-15 pin 2-row male
Cable length
0,50 = 0,50m1,00 = 1,00m1,50 = 1,50m2,00 = 2,00m2,50 = 2,50m3,00 = 3,00m4,00 = 4,00m5,00 = 5,00m6,00 = 6,00m
Design of the scanning head
20 = Standard21 = Standard, flat
Interface
07 = TTL08 = 1Vpp
Functional safety.. = NoFA = Analog signal (1Vpp) can be used for safety related equipment 1)
- , - -30 . -LMK- 20 S
1) Option „FA“ only used for dividing factor „01“.
16
LMK-3010 or LMK-3005 series• Composed of AK LMK-3010 or LMK-3005 and measuring scale (guided)
• Grating period 1000µm or 500µm
• Encoder with integrated electronics
• Guided measuring system
Design 30
Tolerance priciple in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
Tolerierungsgrundsatz nach ISO 8015Allgemeintoleranz nach ISO 2768-fHAlle Maße in mm
H2 = Reference track markingH3 = Direction of scanning head movement for positive counting
Tolerance priciple in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
2x 4,5
11 10
M3/5 deep
2
58
52
~9
4,
5
23,
5
31,
5
Mounting spring
34 2
4
46,5
2x 3,3 H2
RI Marking plate52x10x0,5
H2
Scale fixing bracket
51
2
19
39 4
6
H3
17
Ordering codeLMK - Scanning head for linear guided encodersGrating period 1000µm or 500µm
Interpolation/ Dividing factor
1Vpp TTL
S HA S HA
01 1-fold × ×
05 5-fold ×
10 10-fold ×
25 25-fold × ×
50 50-fold x ×
A3 250-fold ×
A4 500-fold ×
A9 2500-fold ×
- - , - -.LMK-
Pin configuration
UJ = 01,02S12,03S12, 27S12J5 = 16S15
30 30
Electrical connection
01 = Free cable end02S12 = M23-12 pin connector male03S12 = M23-12 pin coupling male16S15 = D-Sub-15 pin 2-row male
Cable length
0,50 = 0,50m1,00 = 1,00m1,50 = 1,50m2,00 = 2,00m2,50 = 2,50m3,00 = 3,00m4,00 = 4,00m5,00 = 5,00m6,00 = 6,00m
Performance
S = StandardHA = High Accuracy
Interface
07 = TTL08 = 1Vpp
Reference mark
RV = Rectangle pulse linked (90° el) /for TTL RI = Rectangle pulse linked (360° el) /for 1Vpp
Functional safety
.. = NoFA = Analog signal (1Vpp) can be used for safety related equipment 1)
1) Option „FA“ only used for dividing factor „01“.
Grating period
10 = 1000µm05 = 500µm
18
Scanning head guided1000µm
LMK-3010
Performance Standard High Accuracy
Interface 1Vpp TTL 1Vpp TTL
Position error per grating period ± 2µm ± 0,5µm
Maximum speed 3m/s limited by the mechanics
TTL - interpolation/ 1Vpp signal period
Signal period 1)
Interpolation--
250µm to 1µm1 to 250
--
0,5µm or 0,1µm500 or 2500
Signal period Dividing factor
1000µm or 40µm1 or 25
--
20µm50
--
Max. output frequency 400KHz 5MHz 400KHz 5MHz
Electrical connection Cable with M23 coupling 12pin male
Cable length on the encoder 0,50m - 6,00m
Power supply 1Vpp: DC 4,0V to 7,0VTTL: DC 5,0V +/- 0,5V
Power consumption ≤ 1300mW at 5V
Typ. current consumption ≤ 220mA at 5V (without load)
Vibration < 200m/s² for 55 - 2000Hz
Shock < 2000 m/s2 for 6ms
Operating temperature 0°C to 80°C
Storage temperature -20°C to 100°C
Protection IP67
Weight 200g
Technical dataLMK - Scanning head for linear guided encodersGrating period 1000µm
1) After 4-edge-evaluation.
19
Technical dataLMK - Scanning head for linear guided encodersGrating period 500µm
Scanning head guided500µm
LMK-3005
Performance Standard High Accuracy
Interface 1Vpp TTL 1Vpp TTL
Position error per grating period ± 1,5µm ± 0,3µm
Maximum speed 3m/s limited by the mechanics
TTL - interpolation/ 1Vpp signal period
Signal period 1) Interpolation
--
125µm to 0,5µm1 to 250
--
0,25µm or 0,05µm500 or 2500
Signal period Dividing factor
500µm or 20µm1 or 25
--
10µm50
--
Max. output frequency 400KHz 5MHz 400KHz 5MHz
Electrical connection Cable with M23 coupling 12pin male
Cable length on the encoder 0,50m - 6,00m
Power supply 1Vpp: DC 4,0V to 7,0VTTL: DC 5,0V +/- 0,5V
Power consumption ≤ 1300mW at 5V
Typ. current consumption ≤ 220mA at 5V (without load)
Vibration < 200m/s² for 55 - 2000Hz
Shock < 2000 m/s2 for 6ms
Operating temperature 0°C to 80°C
Storage temperature -20°C to 100°C
Protection IP67
Weight 200g
1) After 4-edge-evaluation.
20
67 22
14,
5
4
27
~9
4,5
0
8
9
25
17
4,50
H4
67 22 ~20
14,
5 27
4
4,5
17
25
9
8 H4
Design 10
Design 12
Tolerance priciple in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
Tolerierungsgrundsatz nach ISO 8015Allgemeintoleranz nach ISO 2768-fHAlle Maße in mm
External electronicsGeneral
• Miniaturized scanning head• With external electronics on the cable• Output: Flange socket M23
• Miniaturized scanning head• With external electronics, pluggable on
cable via M12 connector• Output: Flange socket M23
H4 = Mounting surfaceTolerance priciple in accordance with ISO 8015General tolerances in accordance with ISO 2768-fHAll dimensions in mm
21
Pin configurationElectrical connection: 16S1515-pin Sub-D-connector
Electrical connection: 03S1212-pin coupling M23
Electrical connection: 02S1212-pin connector M23
Power supply Incremental signals Other signals
4 12 2 10 1 9 3 11 14 7 5/15 8 6
12 2 10 11 5 6 8 1 3 4 / 7 9
UP SensorUP
0 V Sensor0 V
A+ A– B+ B– R+ R– Free Diag+ Diag-
brown/green
blue white/green
white brown green grey pink red black / violet yellow
Cable Shield is connected with the housing; UP = Power voltage supplySensor: The sensor wire is connected internally with the corresponding power supply.Non-used pins or wires must not be assigned!DIAG-wires must not be assigned!DIAG-signals are for checking the encoder with AMO-STU-60.
InterfaceIncremental signals » 1 Vpp
AMO-measuring systems with » 1-Vpp-Interface are outputing signals which can be highly interpolated.
The sine shaped incremental signals A and B are electrically 90° phase shifted and have a signal strength from 1Vpp. The showed sequence of the outputed signals - B after A - is valid for the in the connection drawing stated movement direction.
The reference mark signal R has a clear assignment to the incremental signals.
22
InterfaceIncremental signals « TTL
AMO-measuring systems with « TTL Interface contain electronic, which form the sine-form signals - with or without -Interpolation into digital signals.
The incremental signals are outputed as rectangle pulses A+ and B+ with 90° el. phase shifting.The rectangle-mark-signal is composed from one or more reference impulses R+, which are assigned with the incremental signalsThe integrated electronic additionally creates the inverse signals A-, B- and R- for a safe transmission.The showed sequence of the outputed signals - B after A - is valid for the in the connection drawing stated movement direction.
The Measuring Step results through the distance between two flanks from the incremental signals A+ and B+ through 1 fold-, 2 fold- or 4-fold evaluation.
Signal periode 360° el.
Measuring step after 4fold-evaluation
The inverse signals A-, B- und R- are not shown.
A+
B+
R+
Pin configurationElectrical connection: 16S1515-pin Sub-D-connector
Electrical connection: 03S1212-pin coupling M23
Electrical connection: 02S1212-pin connector M23
Power supply Incremental signals Other signals
4 12 2 10 1 9 3 11 14 7 5/15 8 6
12 2 10 11 5 6 8 1 3 4 / 7 9
UP SensorUP
0 V Sensor0 V
A+ A– B+ B– R+ R– Free Diag+ Diag-
brown/green
blue white/green
white brown green grey pink red black / violet yellow
Cable Shield is connected with the housing; UP = Power supply voltageSensor: The sensor wire is connected internally with the corresponding power supply.Non-used pins or wires must not be assigned!DIAG-wires must not be assigned!DIAG-signals are for checking the encoder with AMO-STU-60.
Headquarter:
A-4963 St. Peter am Hart, Nöfing 4 - Austria
Phone: +43 7722 658 56-0Fax: +43 7722 658 56-11
e-mail: [email protected]
www.amo-gmbh.com
Branches:
Germany:
AMO GmbHZweigniederlassung Deutschland
Bussardstrasse 10D 78655 Dunningen
Phone: +49 7403 913 283Fax: +49 7403 913 267
e-mail: [email protected]: www.amo-gmbh.com
USA:
AMO Corporation9580 Oak Ave Parkway Suite 7-162
Folsom, CA 95630
Phone: +1 916 791 2001Fax: +1 916 720 0430
e-mail: [email protected]: www.amosin.com
Italy:
AMO Italia s.r.l.20128 Milano MI - Italia
Via Asiago 14
Phone: +39 029 108 23 41
e-mail: [email protected]: www.amoitalia.it
Authorized dustributors and sales partners in other countries:Please look at www.amo-gmbh.com
Technische Änderungen vorbehalten.Technical data are subject to change without notice. PI_LIN_INC_0816_EN