InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
OIL
CO
OLI
NG
EQ
UIP
ME
NT
O
O-13
Super Unit
Multi-stage pressure/flow rate control (16 P-Q control setting patterns)The force (pressure) of the actuator (cylinder), and the speed (flow rate) can be controlled as sixteen pressure/flow rate (P/Q) combinations. ・ The proportional control valve and proportional pressure control valve, which are utilized in conventional actuator
circuits, can be omitted. The pressure and flow rate can be set from the controllerʼ s operation panel, and sixteen different pressure/flow rate settings can be selected using external input signals.
・ Switching from flow rate control to pressure control is handled autonomously at the Super Unit. (For example, there is a switch from flow rate to pressure control at the cylinder stroke end.)
・ The ON/OFF control of the solenoid valve for cylinder operation requires operation at the machine.
There is smooth switching between force (pressure) and speed (flow rate).・ Once acceleration time and deceleration time parameters are registered, the force or speed can be changed gradually
during a pressure/flow rate setting change. Maintenance/Management Function (Hybrid-Win)
Internal data of the Super Unit can be obtained by using PC connected to the unit.
• The pressure, flow rate, and other internal data of the inverter can be monitored and displayed in the form of graphs. This facilitates operation checks during test runs, adjustment of parameters such as time constants, and troubleshooting.
• The time required for setting can be slashed by editing the parameter settings on the PC and writing them to the unit in a batch. The ability to read and save settings facilitates management.
Functions
16PQ
4PQ
Com. Hyb.Win
Featured with standard models
Featured with standard models
P C t o o l
Supported
Excluded from high-efficiency motor regulations The high-efficiency motor regulations took effect in Japan from April 2015.These regulations apply to the hydraulic units equipped with induction motors. This Super Units will be exempted from these regulations by adopting a special-design inverter motor.
50% reduction in power consumption (in the pressure holding time compared with Daikin conventional pump.) Daikin original high-efficiency IPM motor drive system with inverter technologies provides a high energy-saving ratio of 50%.
Low noise level 60 dB(A)An operating noise level of 60 dB (A) has been achieved with double pump specifications at the holding pressure of 20.6 MPa. The noise level does not exceed 73 dB (A) even over the full operating range.
Conforming to CE standardsAll models conform to the machinery directive, EMC directive, and low voltage directive to facilitate CE approval of the main machine.
Restricted oil temperature riseMotor speed control also leads to restriction of the oil temperature rise.This inhibits deterioration of the hydraulic oil, which helps to reduce costs and prevent environmental pollution. In addition to improving the working environment, it can also be expected to generate further energy savings by lowering the load on air conditioning equipment.
Features
Advantages of using hybrid hydraulic units
(1) Eliminates motor replacement work for each destination(2) Eliminates machine design change in accordance with amendment of
the regulations.(3) Reduces design changes to spare parts, and saves maintenance time.
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
O-14
Nomenclature
SUT 03 S 15 07 - 30 - - - 1 2 3 4 5 6 7 8 9
SUT 00 S 110 07 - 30 - - 1 2 3 4 5 6 7 8
Equivalent to 2.2 to 7.0 kW
Equivalent to 11 kW
1 Model No.SUT: SUT series
7 Function Option
Design No.Incremented at model changes
0003061016
:::::
Tankless type30 L60 L100 L160 L
2 Tank capacity
4 Pump discharge rate 6
5 Maximum operating pressure
8 9 Non-standard No.1530406080
:::::
1530406080
L/minL/minL/minL/minL/min
07101621
::::
MPaMPa,16.0 MPaMPa
C
P
:
:
With communication function (RS232C)With analog input function
01
Hardware OptionUnit cover (except for 30 L tank)
02
03 DCL (except for 7 kW)
04
05 Water fill test compliant tank06 Water leak test compliant tank07 Level switch08 Temperature switch09 Thermometer10 Micro separator11 Combination of 1 to 10 above...
DS
::
Double pump typeSingle pump type
3 Pump type
7.010.015.720.6
Controller cover (except for 7 kW and higher)
Separation of power supplies for power and control lines
N: Without control systemA: With control system
1 Model No.SUT : SUT series
7 Function Option
2 Tank capacity4 Pump discharge rate Design No.
Incremented at model changes6
5 Maximum operating pressure 8 N: Without control systemA: With control system
Non-standard No.C
P
:
:
With communication function (RS232C)With analog input function
DS
::
Double pump typeSingle pump type
3 Pump type
00 : Tankless type110 : 110 L/min
0721
: :
7.020.6
MPaMPa
C: With communication function (RS232C) Remote control and setting changes are possible through RS232C serial communication.
01: Unit cover The cover protects the controller unit and piping.
02: Controller cover The metal cover protects the controller unit.
03: With DCL (DC reactor) Appropriate when it is necessary to improve the power factor or reduce the harmonics of the power supply This is provided as an option for compact models of 5 kW and smaller. For models of 7 kW and larger, it is installed as standard.
04: Separate power supplies for power system and control system When an error occurs, only the main power supply is shut down and control power supply continues to carry current, thereby enabling the alarm code and internal status on occurrence of an error to be checked on the operation panel or through serial communication.
05: Water fill test compliant tank, 06 : Water leak test compliant tank We implement the water fill test that is one of the criteria for compliance with Japanese Fire Services Act, and the water leak test that is Daikin's own criterion. Products are shipped with a test-compliance name plate affixed, and with a pass certificate. (A water fill test compliant tank is not equivalent to a Fire Services Act-compliant tank.)
07: Level switch, 08: Temperature switch, 09: Thermometer, 10: Microseparator These accessories for fitting to the tank are provided as options. The accessories can also be purchased as optional parts.
Optional function
Hardware option
16PQ
4PQ
Com. Hyb.Win
P: With analog input function Enables linear control of pressures and flow rates as required.
Analog
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
OIL
CO
OLI
NG
EQ
UIP
ME
NT
O
O-15
List of Models with Options Installed
Model code
SUT00S1507-30
Single pump
SUT00S3007-30
SUT00S1510-30
SUT00S4007-30
SUT00S3010-30
SUT00S1516-30
SUT00S3016-30
SUT00S6007-30
SUT00D4016-30
Double pump
SUT03S1507-30
SUT03S3007-30
SUT03S1510-30
SUT03S4007-30
SUT03S3010-30
SUT03S1516-30
SUT06S3016-30
SUT06S6007-30
SUT06D4016-30
SUT10D6021-30
SUT16D8021-30
SUT06D6021-30
SUT10D8021-30
SUT00S8007-30
SUT10S8007-30
SUT00D6021-30
SUT00D8021-30
C P
Unit cover(01)
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
Controller cover(02)
−
−
−
−
−
−
−
−
−
−
DCL(03)
−
−
−
−
−
−
−
−
−
−
−
−
Function Option Hardware Option
* Tank inspections : Water fill test compliant tank (05), water leak test compliant tank (06) Unit accessories : Level switch (07), temperature switch (08), thermometer (09), microseparator (10)
Setting available − No setting
Motor capacity
Separation of power supplies for power and
control lines (04)
Tank inspection / Unit accessory
(*)
Equivalent to 2.2 kW
Equivalent to 2.8 kW
Equivalent to 3.7 kW
Equivalent to 5.0 kW
Equivalent to 7.0 kW
Equivalent to 3.7 kW
Equivalent to 5.0 kW
Equivalent to 7.0 kW
Pump specifications
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
O-16
Specifications
Pressure – Flow rate characteristics (Example)Maximum operating pressure 7 MPa
Maximum discharge rate 15/30 L/minModel code
SUTS1507-30SUTS3007-30
Super Unit [Single pump type]
Flow
rate
(L/m
in)
Pressure (MPa)
10
20
30
40
60
80
90
100
110
50
70
2 4 6 8 10 12 14 161 3 5 7 9 11 13 15
SUTS407
SUTS3007
SUTS1507
SUTS6007
SUTS8007
SUTS11007
SUTS4007
SUTS3007
SUTS1507
SUTS6007
SUTS8007
SUTS11007
* Operating flow rate at the maximum pressure in continuous operation:SUTS1507: 3 L/min maximumSUTS3007: 5 L/min maximum
* The graph shows actual flow rates (representative values).
SUT00S 1507-30
SUT00S 3007-10-F
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
Model SUT03S 15L07-10-F
External input signal5 channels
59
Motor pump/unitPower supply
AC3 φ 200 V (50 Hz)Rated current
(A)
Usable oil *2
Others
Operating conditions
Operating hydraulic oil temperature
Operating ambient temperature
Storage ambient temperature
Operating ambient humidity
Installation site
AC3 φ 200 V (60 Hz)
AC3 φ 220 V (60 Hz)
Power source breaker setting (A)
Mass (kg)
15
Standard coating color
Pump unit
Maximum discharge rate (Theoretical value; L/min) *1
Motor capacity (Equivalent kW)Motor capacity
Maximum operating pressure (MPa)
Operating flow rate adjustment range (L/min)
Operating pressure adjustment range (MPa)
11.5
11.3
10.6
Tank capacity (L)
15.4
15.1
13.8
20
11.5
11.3
10.6
15
15.4
15.1
13.8
20
37 39
28.5
3.5 to 28.5
15.2
2.5 to 15.2
Equivalent to 2.8 kWEquivalent to 2.2 kW
1.5 to 7.0
7.0
28.5
3.5 to 28.5
15.2
2.5 to 15.2
Equivalent to 2.8 kWEquivalent to 2.2 kW
Contact outputExternal
output signalDigital output
SUT03S 30L07-10-F
3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
− 30
0 to 40°C
−20 to 60°C
85% RH maximum (No condensation)
Indoors (Be sure to secure the unit with bolts.)
Ivory white (Munsell code 5Y7.5/1)
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.
1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)
2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
Tankless type Unit type
Tankless type Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
OIL
CO
OLI
NG
EQ
UIP
ME
NT
O
O-17
External dimension diagram
Tankless type
Unit type
8 1
Unit nameplate
φ21 hole(Signal cable port)(Power cable port)
φ28 hole
30 284 30
344
45(4
21)
(Fitted with a vinyl cap at shipment)
(Fitted with a vinyl cap at shipment)
(83)
(109
)
(246
)
(260
)
3046030
520
45(2
20)
(466
)
Rc⅜
Suction port: G¾
(Fitted with a vinyl cap at shipment)
(87)
1549015
520
(162
)
(254
)15
314
1534
4
Pressure indication and operation panel Rc⅜
3
1-2
DR
(Fitted with a vinyl cap at shipment)Rp¾ (above oil level)DR
P
(Fitted with a vinyl cap at shipment)
Rc⅜P
(Fitted with a vinyl cap at shipment)
Rc1T
170150(75)(175)
132.5 550
Optional port: Rp⅜
Optional port: Rp½
100
(Manifold bracket mount)
50
4-M8
42
92
140
(M12 bolts recommended)4-φ15 holes (for fixing bolts)
(M8 bolts recommended)4-φ10 holes (for fixing bolts)
Pressure indication and display panel
Foundation plate (Option)(E-SUTPLATE-2)
(620)196
(40)(40)
φ21 hole(Signal cable port)
(Power cable port)
φ28 hole
70
20 10 30 30 25
4020
2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)
700530 8585
Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)
95
419
(516
)
30 LUpper limit (Yellow line)23 LLower limit (Red line)
462
Cleaning port
450500
Oil sampling port/Oil drain port: Rc½
(550)(580)
70 155
(50)
309
6-1
5 4
8
7
Suction air
6-2
1
2
2
1-1
3
Suction air
Safety caution nameplate
Unit nameplate
Safety caution nameplate
Wing bolt for fastening during transportation (at 1 location)(To be removed before operation)
SUT00S1507-30SUT00S3007-30
Part No. Name Quantity
1-1 Inverter driven motor pump 1
1-2 Controller 1
2 AC fan 1
3 Base 1
SUT03S1507-30 SUT03S3007-30
Part No. Name Quantity
1 1
2 1
13
14
15
6-1 1
6-2
7 1
1
Oil tank
Suction strainer
Stop valve
Oil level gauge
Oil filler port with air breather
Inverter driven motor pump
Controller
Oil cooler
AC fan
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
O-18
Specifications
Pressure – Flow rate characteristics (Example)Maximum operating pressure 7 MPa
Maximum discharge rate 40 L/minModel code
SUTS4007-30
Super Unit [Single pump type]
Flow
rate
(L/m
in)
Pressure (MPa)
10
20
30
40
60
80
90
100
110
50
70
2 4 6 8 10 12 14 161 3 5 7 9 11 13 15
SUTS307
SUTS6007
SUTS8007
SUTS1507
SUTS11007
SUTS4007
SUTS3007
SUTS6007
SUTS8007
SUTS1507
SUTS11007
SUTS4007
* Operating flow rate at the maximum pressure in continuous operation:8 L/min maximum
* The graph shows actual flow rates (representative values).
SUT00S4007-30
5 channels
64
20
16.1
15.8
14.8
46
1.5 to 7.0
7.0
5.3 to 39.7
Equivalent to 3.7 kW
3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
− 30
0 to 40°C
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
−20 to 60°C
85% RH max. (No condensation)
Indoors (Be sure to secure the unit with bolts.)
Ivory white (Munsell code 5Y7.5/1)
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.
1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)
Tankless type Unit type
39.7
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
SUT03S4007-30
2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
Model
External input signal
Motor pump/unitPower supply
AC3 φ 200 V (50 Hz)Rated current
(A)
Usable oil *2
Others
Operating conditions
Operating hydraulic oil temperature
Operating ambient temperature
Storage ambient temperature
Operating ambient humidity
Installation site
AC3 φ 200 V (60 Hz)
AC3 φ 220 V (60 Hz)
Power source breaker setting (A)
Mass (kg)
Standard coating color
Pump unit
Maximum discharge rate (Theoretical value; L/min) *1
Motor capacity (Equivalent kW)Motor capacity
Maximum operating pressure (MPa)
Operating flow rate adjustment range (L/min)
Operating pressure adjustment range (MPa)
Tank capacity (L)
Contact outputExternal
output signalDigital output
Tankless type Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
OIL
CO
OLI
NG
EQ
UIP
ME
NT
O
O-19
External dimension diagram
Tankless type
Unit type
SUT00S4007-30
1-1 1
1-2 1
2 1
3 1
SUT03S4007-30
Part No. Name Quantity
1 Oil tank 1
2 Suction strainer 1
3 Stop valve 1
4 Oil level gauge 1
5 Oil filler port with air breather 1
6-1 Inverter driven motor pump 1
6-2 Controller
7 Oil cooler 1
8 AC fan 1
1
Safety caution nameplate
(294
)
1535
415
384
(87)1549015
520
30 324 30
384
45(4
21)
(202
)
45
220
(466
)
(108
)
(245
)(2
59)
(83)
30 460 30
520
Rc½P
Rc⅜DR
DR
1-2
1-1
3
2
Rc1T
4-M8
17015077.5177.5
132.5 550
42
92
5010
014
0.5
(620)196
(40) (40)
2595
419
(516
)
70
20 10 30 30
4020
700530 8585
450500
70 155
(50)
(309
)
(550)(580)
462
6-1
5 4
8
7
6-2
2
1
3
(M8 bolts recommended)4-φ10 holes (for fixing bolts)
(Power cable port)φ28 hole φ21 hole
(Signal cable port)
Wing bolt for fastening during transportation (at 1 location)(To be removed before operation)
Foundation plate (Option)(E-SUTPLATE-2)
30 LUpper limit (Yellow line)23 LLower limit (Red line)
(Fitted with a vinyl cap at shipment)
(Fitted with a vinyl cap at shipment)
Suction port: G¾
(Fitted with a vinyl cap at shipment)
Pressure indication and operation panel
(Fitted with a vinyl cap at shipment)Rp¾ (above oil level)
(Fitted with a vinyl cap at shipment)
Rc½P
(Fitted with a vinyl cap at shipment)
Optional port: Rp⅜
Optional port: Rp½
(Manifold bracket mount)
(M12 bolts recommended)4-φ15 holes (for fixing bolts)
Pressure indication and display panel
φ21 hole(Signal cable port)
(Power cable port)
φ28 hole
2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)
Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)
Cleaning port
Oil sampling port/Oil drain port: Rc½
Suction air
Suction air
Safety caution nameplate
Unit nameplate
Part No. Name Quantity
Inverter driven motor pump
Controller
AC fan
Base
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
O-20
Specifications
Pressure – Flow rate characteristics (Example)Maximum operating pressure 7 MPa
Maximum discharge rate 60 L/minModel code
SUT00S6007-30SUT06S6007-30
Super Unit [Single pump type]
Flow
rate
(L/m
in)
Pressure (MPa)
10
20
30
40
60
80
90
100
110
50
70
2 4 6 8 10 12 14 161 3 5 7 9 11 13 15
SUTS3007
SUTS4007 SUTS4007
SUTS6007
SUTS8007
SUTS1507
SUTS1107
SUTS3007
SUTS4007
SUTS6007
SUTS8007
SUTS1507
SUTS11007
* Operating flow rate at the maximum pressure in continuous operation:14 L/min maximum
* The graph shows actual flow rates (representative values).
SUT00S6007-30 SUT06S6007-30
30
22.1
21.7
20.2
56
1.5 to 7.0
7.0
8.7 to 61.1
Equivalent to 5.0 kW
3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
− 60
0 to 40°C
−20 to 60°C
85% RH maximum (No condensation)
Indoors (Be sure to secure the unit with bolts.)
Ivory white (Munsell code 5Y7.5/1)
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.
1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)
Tankless type Unit type
61.1
5 channels
97
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
Model
External input signal
Motor pump/unitPower supply
AC3 φ 200 V (50 Hz)Rated current
(A)
Usable oil *2
Others
Operating conditions
Operating hydraulic oil temperature
Operating ambient temperature
Storage ambient temperature
Operating ambient humidity
Installation site
AC3 φ 200 V (60 Hz)
AC3 φ 220 V (60 Hz)
Power source breaker setting (A)
Mass (kg)
Standard coating color
Pump unit
Maximum discharge rate (Theoretical value; L/min) *1
Motor capacity (Equivalent kW)Motor capacity
Maximum operating pressure (MPa)
Operating flow rate adjustment range (L/min)
Operating pressure adjustment range (MPa)
Tank capacity (L)
Contact outputExternal
output signalDigital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
Tankless type
Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
OIL
CO
OLI
NG
EQ
UIP
ME
NT
O
O-21
SUT00S6007-30
SUT06S60L07-20-F
Part No. Name Quantity
6-1 Inverter driven motor pump 16-2 Controller 1
2 Suction strainer 13 Stop valve 14 Oil level gauge 15 Oil filler port with air breather 1
7 Oil cooler
1 Oil tank 1
8 AC fan 19 Return filter 1
110 Check valve
1
Part No. Name Quantity
1-1 Inverter driven motor pump 1
1-2 Controller 1
2 AC fan 1
3 Base 1
4 Check valve 1
BoltCaution plate
(Fitted with a vinyl cap at shipment)
Rc¾P
1-2
2
1-1
3
4
(294
)15
354
1538
4
Pressure indication and operation panel
Unloading port Rc½(Fitted with a vinyl cap at shipment)
(136)
1557815608
(95) (1
80)
(73)
(140)
(Fitted with a vinyl cap at shipment)
Rc⅜
(Fitted with a vinyl cap at shipment)
DR
(86)(143)
608
(95)
(226
)(2
82)
(466
)
3054830
Suction port: Rc1
45(4
21)
3032430
384
φ21 hole(Signal cable port)(Power cable port)
φ28 hole
(Fitted with a vinyl cap at shipment)
Rc1T
(plugged at factory)Rc¾T
(Fitted with a vinyl cap at shipment)Rp¾ (above oil level)DR
4-M8
(Fitted with a vinyl cap at shipment)
Rc¾P
Foundation plate (Option)(E-SUTPLATE-2)Pressure indication and operation panel
2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)
17015018832710085
3711
0
42
100
50
(311
)
(620) (40)
Optional port: Rp⅜
Optional port: Rp½
(40)
20 10530
30 30 25
4020
595
8585(707)
648
70 95(4
41)
450500
70
(50)
Oil sampling port/Oil drain port: Rc½
639
716
Cleaning port
60 LUpper limit (Yellow line)
45 LLower limit (Red line)
155
59 104
6-2
6-12
1
8
7
3
(M8 bolts recommended)4-φ10 holes (for fixing bolts)
(M12 bolts recommended)4-φ15 holes (for fixing bolts)
Suction air
Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)
(241
)
Safety caution nameplate
Unit nameplate
Safety caution nameplate
Unit nameplate
Suction airWing bolt for fastening during
transportation (at 1 location)(To be removed before operation)
(Manifold bracket mount)
External dimension diagram
Tankless type
Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
O-22
Specifications
Pressure – Flow rate characteristics (Example)Maximum operating pressure 7 MPa
Maximum discharge rate 80 L/minModel code
SUTS8007-30
Super Unit [Single pump type]
Flow
rate
(L/m
in)
Pressure (MPa)
10
20
30
40
60
80
90
100
110
50
70
2 4 6 8 10 12 14 161 3 5 7 9 11 13 15
SUTS3007
SUTS4007 SUTS4007
SUTS6007
SUTS8007
SUTS1507
SUTS11007
SUTS3007
SUTS4007
SUTS6007
SUTS8007
SUTS1507
SUTS11007
* Operating flow rate at the maximum pressure in continuous operation:19 L/min maximum
* The graph shows actual flow rates (representative values).
50
25.5
24.8
22.7
72
1.5 to 7.0
7.0
11.6 to 83.0
Equivalent to 7.0 kW
3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
− 100
0 to 40°C
−20 to 60°C
85% RH max. (No condensation)
Indoors (Be sure to secure the unit with bolts.)
Ivory white (Munsell code 5Y7.5/1)
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.
1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)
Tankless type Unit type
83.0
5 channels
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
131
50
Model
External input signal
Motor pump/unitPower supply
AC3 φ 200 V (50 Hz)Rated current
(A)
Usable oil *2
Others
Operating conditions
Operating hydraulic oil temperature
Operating ambient temperature
Storage ambient temperature
Operating ambient humidity
Installation site
AC3 φ 200 V (60 Hz)
AC3 φ 220 V (60 Hz)
Power source breaker setting (A)
Mass (kg)
Standard coating color
Pump unit
Maximum discharge rate (Theoretical value; L/min) *1
Motor capacity (Equivalent kW)Motor capacity
Maximum operating pressure (MPa)
Operating flow rate adjustment range (L/min)
Operating pressure adjustment range (MPa)
Tank capacity (L)
Contact outputExternal
output signalDigital output
SUT00S8007-30 SUT10S8007-30
2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
Tankless type
Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
OIL
CO
OLI
NG
EQ
UIP
ME
NT
O
O-23
SUT00S8007-30
Part No. Name Quantity
1-1 Inverter driven motor pump 1
1-2 Controller 1
2 AC fan 1
3 Base 1
4 Check valve 1
Transportation nameplate
(441
)45
3032430
(260
)
(486
)
(To be removed before operation)
Wing bolt for fastening during transportation (at 2 locations)
(Plugged (with O-ring) at shipment)
Suction port: Rc1(142)3057030 3
(244
)
(90)
(300
) (408
)
1-1
(85.5)
1-2
15 1515(135)
600630(60)
Motor cable
1535
438
4 294
(Fitted with a vinyl cap at shipment)
Unloading port: Rc½
(196
)(1
25)
(139)
4
SUT10S8007‐30
(Fitted with a vinyl cap at shipment)
Rc¾P
Pressure indication and operation panel
(Fitted with a vinyl cap at shipment)Rc⅜DR
Part No. Name Quantity
6-1 Inverter driven motor pump 16-2 Controller 1
2 Suction strainer 13 Stop valve 14 Oil level gauge 15 Oil filler port with air breather 1
7 Oil cooler
1 Oil tank 1
8 AC fan 19 Return filter 1
110 Check valve
1
(M8 bolts recommended)4-φ10 holes (for fixing bolts)
BoltCaution plate
Cleaning port tightening caution nameplate
Safety caution nameplate
Unit nameplateSUT10D80L07-30
(plugged at factory)Rc1-¼
(Fitted with a vinyl cap at shipment)Rp¾ (above oil level)DR
(Manifold bracket mount)4-M8
Pressure indication and operation panel
(Fitted with a vinyl cap at shipment)
Rc1-½T
T
(Fitted with a vinyl cap at shipment)
Rc¾P
Foundation plate (Option)(E-SUTPLATE-2)
2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)
Wing bolt for fastening during transportation (at 1 location on the back)
(To be removed before operation)
100 LUpper limit (Yellow line)76 LLower limit (Red line)
3
59
10
46-2
6-1
2
1
8
7
170150
(188)(327)100(85)
(620)
100
50
(439
)
(40) (40)
150
172
17
Optional port: Rp⅜Optional port: Rp½
70
10
700530
30 30
25
4020
59567
1
208585
95(4
41)
(188)(895)
(216
)
580630
70 155(50)
Oil sampling port/Oil drain port: Rc½
450 50 80
(647
)
Cleaning port
(M12 bolts recommended)4-φ15 holes (for fixing bolts)
2
Suction air
Suction air
754
Safety caution nameplate
Unit nameplate
External dimension diagram
Tankless type
Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
O-24
Specifications
Pressure – Flow rate characteristics (Example)Maximum operating pressure 7 MPa
Maximum discharge rate 110 L/minModel code
SUT00S11007-30
Super Unit [Single pump type]
Flow
rate
(L/m
in)
Pressure (MPa)
10
20
30
40
60
80
90
100
110
50
70
2 4 6 8 10 12 14 161 3 5 7 9 11 13 15
SUTS3007
SUTS4007
SUTS6007
SUTS8007
SUTS1507
SUTS11007
SUTS3007
SUTS4007
SUTS6007
SUTS8007
SUTS1507
SUTS11007
* Operating flow rate at the maximum pressure in continuous operation:16 L/min maximum
* The graph shows actual flow rates (representative values).
SUT00S11007-30
38.3
37.8
34.9
112
1.5 to 7.0
7.0
13.3 to 110
Equivalent to 11.0 kW
3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
−
0 to 40°C
−20 to 60°C
85% RH max. (No condensation)
Indoors (Be sure to secure the unit with bolts.)
Ivory white (Munsell code 5Y7.5/1)
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.
1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)
Tankless type
110
5 channels
75
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
Model
External input signal
Motor pumpPower supply
AC3 φ 200 V (50 Hz)Rated current
(A)
Usable oil *2
Others
Operating conditions
Operating hydraulic oil temperature
Operating ambient temperature
Storage ambient temperature
Operating ambient humidity
Installation site
AC3 φ 200 V (60 Hz)
AC3 φ 220 V (60 Hz)
Power source breaker setting (A)
Mass (kg)
Standard coating color
Pump unit
Maximum discharge rate (Theoretical value; L/min) *1
Motor capacity (Equivalent kW)Motor capacity
Maximum operating pressure (MPa)
Operating flow rate adjustment range (L/min)
Operating pressure adjustment range (MPa)
Tank capacity (L)
Contact outputExternal
output signalDigital output
Tankless type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
OIL
CO
OLI
NG
EQ
UIP
ME
NT
O
O-25
SUT00S11007-30SUT00D11021-30Controller (Installed separately)
SUT00S11007-30
DAIKIN INDUSTRIES,LTD. MADE IN JAPAN
SUT00S※※※※※-※※-A-※INSULATION CLASS : F
V3φ 2003φ 2003φ 220
Hz0.9450
6060
MASSMAX. FLOWMAX.PRESSURE: 17.6 MPa
: 80 L/min: 88 kg
DAIKIN INDUSTRIES,LTD. MADE IN JAPAN
注1.MFG No.:
0.940.9461
6262A PF
204117
261
15
241
108 108
228
170
323
168 496
42 118
243
207
112
76.5 95.5 132.5
275228
151
819
19
**
IC
N
CE
D
129
9587
INSULATION CLASS : FV
3φ 2003φ 2003φ 220
Hz506060
MASSMAX. FLOWMAX.PRESSURE: MPa
: L/min: kg
DAIKIN INDUSTRIES,LTD. MADE IN JAPAN
MFG No.:
A PF
WARNING
May cause
Wait 5 minutes until
・Disconnect all power
DC Bus capacitors
electric shock.
感電のおそれがあります。 ターミナルカバーを開けないで下さい。・通電中及び電源遮断後5分以内は
DAIKIN INDUSTRIES,LTD.
before opening terminal
dischange.
危 険
cover of unit.
FG
GNDFG
Z-+5V
Z+B-
A-
THM-
B+
A+
THM+AGND
AGNDAO2
AO1
AGND
AGND
AGNDP_S
A5V
ALM_B
DOCOM
ALM_C
ALM_A
DO7DO6
DO4DO5
DO3
DO2
DI8
DI6
DO1
DI7
DI5DI4
DI2
DICOM
DI3
DI1
DGNDRxD
FGTxD
FG
(QO)
(PO)
AIN2
AIN1(QI)
(PI)
Cooling fanCooling fan
1732
7.5
34
95.5
233
39
(5)207212
636
111
.5
378.
5
25 180 (25)
230
240
(5)(5)
180
Motor wiring port (φ28)
AC fan, thermistor wiring port (φ21)
Suction port: Rc1-¼
Encoder wiring connector
Drain portRc⅜
Suction air
Discharge portUnloading portRc¾
4-14.5 (Installation)
Rc1-¼
<Top>Cooling fan suction
Cooling fan exhaust
- Encoder- Motor thermistor- Pressure sensor- I/O signal
User I/O terminal (M3)
Controller nameplate
M5 screw (for ground connection)
Controller installation hole4-φ8 (M6 bolts recommended)
Operation panel
Product nameplate
- Main power supply- DC reactor- Regenerative resistor- Motor output
Main power supply terminal block (M5)
M5 screw (for ground connection)
M4 screw (for ground connection)
- Electromagnetic valve power supply- AC fan power supply
Electromagnetic valve terminal block (M4)
External dimension diagram
Tankless type
Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
O-26
Specifications
Pressure – Flow rate characteristics (Example)Maximum operating pressure 10 MPa
Maximum discharge rate 15 L/minModel code
SUTS1510-30
Super Unit [Single pump type]
Flow
rate
(L/m
in)
Pressure (MPa)
10
20
30
40
60
80
90
50
70
2 4 6 8 10 12 14 161 3 5 7 9 11 13 15
SUTS3010
SUTS1510
SUTS3010
SUTS1510
* Operating flow rate at the maximum pressure in continuous operation:3 L/min maximum
* The graph shows actual flow rates (representative values).
SUT00S1510-30 SUT03S1510-30
15
8.0
7.8
7.5
39
1.5 to 10.0
10.0
2.5 to 15.2
Equivalent to 2.8 kW
3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
− 30
0 to 40°C
−20 to 60°C
85% RH max. (No condensation)
Indoors (Be sure to secure the unit with bolts.)
Ivory white (Munsell code 5Y7.5/1)
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.
1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)
Tankless type Unit type
15.2
5 channels
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
59
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
Model
External input signal
Motor pump/unitPower supply
AC3 φ 200 V (50 Hz)Rated current
(A)
Usable oil *2
Others
Operating conditions
Operating hydraulic oil temperature
Operating ambient temperature
Storage ambient temperature
Operating ambient humidity
Installation site
AC3 φ 200 V (60 Hz)
AC3 φ 220 V (60 Hz)
Power source breaker setting (A)
Mass (kg)
Standard coating color
Pump unit
Maximum discharge rate (Theoretical value; L/min) *1
Motor capacity (Equivalent kW)Motor capacity
Maximum operating pressure (MPa)
Operating flow rate adjustment range (L/min)
Operating pressure adjustment range (MPa)
Tank capacity (L)
Contact outputExternal
output signalDigital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
Tankless type Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
OIL
CO
OLI
NG
EQ
UIP
ME
NT
O
O-27
SUT00S1510-30
SUT03S1510-30
Part No. Name Quantity
1-1 Inverter driven motor pump 1
1-2 Controller 1
2 AC fan 1
3 Base 1
Part No. Name Quantity
6-1 Inverter driven motor pump 1
6-2 Controller 1
2 Suction strainer 1
3 Stop valve 1
4 Oil level gauge 1
5 Oil filler port with air breather 1
7 Oil cooler
1 Oil tank 1
1
8 AC fan 1
BoltCaution nameplate
Cleaning port tightening caution nameplate
Unit nameplateSUT03S15L10-30
450500
70 155
(50)
309
(550)(580)
70
20 10 30 30 25
4020
700530 8585
95
419 (5
16)
462
(620)196
140.
5
42
92
100
50
17015077.5177.5
132.5 550
(40)(40)
φ21 hole(Signal cable port)
(Power cable port)φ28 hole
Suction port: G¾
Rc⅜DR
(Fitted with a vinyl cap at shipment)Rc⅜P
1-2
2
1-1
3
(87)1549015
520
(162
)(254
)
1531
415
344
Pressure indication and operation panel
(109
)
(246
)
(260
)
(83)
45(2
20)
(466
)
30 460 30
520
30 284 30
344
45(4
21)
(Fitted with a vinyl cap at shipment)Rp¾ (above oil level)DR
(Fitted with a vinyl cap at shipment)
Rc1T
Optional port: Rp⅜
(Manifold bracket mount)4-M8
Optional port: Rp½
(Fitted with a vinyl cap at shipment)Rc⅜P
Pressure indication and operation panel
Foundation plate (Option)(E-SUTPLATE-2)
3
φ21 hole(Signal cable port)
(Power cable port)φ28 hole
8
7
30 LUpper limit (Yellow line)23 LLower limit (Red line)
2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)
6-1
5 46-2Cleaning port
Oil sampling port/Oil drain port: Rc½
1
(M8 bolts recommended)4-φ10 holes (for fixing bolts)
(M12 bolts recommended)4-φ15 holes (for fixing bolts)
2
Suction air
Suction air
Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)
Safety caution nameplate
Unit nameplate
Safety caution nameplate
(Fitted with a vinyl cap at shipment)
(Fitted with a vinyl cap at shipment)
Wing bolt for fastening during transportation (at 1 location)
(To be removed before operation)
External dimension diagram
Tankless type
Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
O-28
Specifications
Pressure – Flow rate characteristics (Example)Maximum operating pressure 10 MPa
Maximum discharge rate 30 L/minModel code
SUTS3010-30
Super Unit [Single pump type]
Flow
rate
(L/m
in)
Pressure (MPa)
10
20
30
40
60
80
90
50
70
2 4 6 8 10 12 14 161 3 5 7 9 11 13 15
SUTS3010
SUTS1510
SUTS3010
SUTS1510
* Operating flow rate at the maximum pressure in continuous operation:5 L/min maximum
* The graph shows actual flow rates (representative values).
SUT00S3010-30 SUT03S3010-30
20
18.4
18.4
16.9
46
1.5 to 10.0
10.0
3.4 to 25.6
Equivalent to 3.7 kW
3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
− 30
0 to 40°C
−20 to 60°C
85% RH max. (No condensation)
Indoors (Be sure to secure the unit with bolts.)
Ivory white (Munsell code 5Y7.5/1)
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 10 • Volumetric water content: 0.1% maximum
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.
1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)
Tankless type Unit type
25.6
5 channels
64
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
Model
External input signal
Motor pump/unitPower supply
AC3 φ 200 V (50 Hz)Rated current
(A)
Usable oil *2
Others
Operating conditions
Operating hydraulic oil temperature
Operating ambient temperature
Storage ambient temperature
Operating ambient humidity
Installation site
AC3 φ 200 V (60 Hz)
AC3 φ 220 V (60 Hz)
Power source breaker setting (A)
Mass (kg)
Standard coating color
Pump unit
Maximum discharge rate (Theoretical value; L/min) *1
Motor capacity (Equivalent kW)Motor capacity
Maximum operating pressure (MPa)
Operating flow rate adjustment range (L/min)
Operating pressure adjustment range (MPa)
Tank capacity (L)
Contact outputExternal
output signalDigital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
Tankless type Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
OIL
CO
OLI
NG
EQ
UIP
ME
NT
O
O-29
SUT03S30L10-30
SUT00S3010-30
Part No. Name Quantity
1 Oil tank 1
2 Suction strainer 1
3 Stop valve 1
4 Oil level gauge 1
5 Oil filler port with air breather 1
6-1 Inverter driven motor pump 1
6-2 Controller
7 Oil cooler 1
8 AC fan 1
1
Part No. Name Quantity
1-1 Inverter driven motor pump 1
1-2 Controller 1
2 AC fan 1
3 Base 1
BoltCaution nameplate
SUT03S30L10-30Cleaning port tightening caution nameplate
φ21 hole(Signal cable port)
(Fitted with a vinyl cap at shipment)Rc⅜P
(Fitted with a vinyl cap at shipment)Rc⅜DR
Pressure indication and operation panel
(202
)
(87)
1549015
520
520
(294
)
1535
415
384
3046030
(108
)
(245
)
(259
)
(83)
(466
)
220
45(4
21)
30 324 30
384
1-2
1-1
2
3
φ21 hole(Signal cable port)
(Power cable port)φ28 hole
(Fitted with a vinyl cap at shipment)
Rc1T
Optional port: Rp⅜
(Fitted with a vinyl cap at shipment)Rp¾ (above oil level)DR
Optional port: Rp½
(Fitted with a vinyl cap at shipment)Rc⅜P
Foundation plate (Option)(E-SUTPLATE-2)Pressure indication and
operation panel
3
(Manifold bracket mount)4-M8
2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)
6-1
5 4
6-2
2595
419
(516
)
20 10 30 30
700530 8585
704020
(620)196
140
42
92
100
50
170150
132.5 550
77.5177.5
(40) (40)
Cleaning port
Oil sampling port/Oil drain port: Rc½
450500
(550)
(580)
462
70 155
(50)
(309
)
2
1
(Fitted with a vinyl cap at shipment)
Suction port: G¾
(Power cable port)φ28 hole
(M8 bolts recommended)4-φ10 holes (for fixing bolts)
(M12 bolts recommended)4-φ15 holes (for fixing bolts)
8
7
Suction air
Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)
Unit nameplate
Wing bolt for fastening during transportation (at 1 location)(To be removed before operation)
Unit nameplate
Safety caution nameplate
30 LUpper limit (Yellow line)23 LLower limit (Red line)
Suction air
Safety caution nameplate
External dimension diagram
Tankless type
Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
O-30
Specifications
Pressure – Flow rate characteristics (Example)Maximum operating pressure 16 MPa
Maximum discharge rate 15/30 L/minModel code
SUTS1516-30SUTS3016-30
Super Unit [Single pump type]
Flow
rate
(L/m
in)
Pressure (MPa)
10
20
30
40
60
80
90
50
70
2 4 6 8 10 12 14 161 3 5 7 9 11 13 15
SUTS3016
SUTS1516
SUTS3016
SUTS1516
* Operating flow rate at the maximum pressure in continuous operation:5 L/min maximum
* The graph shows actual flow rates (representative values).
SUT00S1516-30 SUT00S3016-30 SUT03S1516-30 SUT06S3016-30
20 30 20 30
46 52 64 83
1.5 to 16.0
16.0
2.4 to 15.2 3.4 to 25.6 2.4 to 15.2 3.4 to 25.6
Equivalent to 3.7 kW Equivalent to 5.0 kW Equivalent to 3.7 kW Equivalent to 5.0 kW
3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
− 30 60
0 to 40°C
−20 to 60°C
85% RH max. (No condensation)
Indoors (Be sure to secure the unit with bolts.)
Ivory white (Munsell code 5Y7.5/1)
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.
1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)
2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
Tankless type Unit type
15.2 25.6 15.2 25.6
5 channels
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
Model
External input signal
Motor pump/unitPower supply
AC3 φ 200 V (50 Hz)Rated current
(A)
Usable oil *2
Others
Operating conditions
Operating hydraulic oil temperature
Operating ambient temperature
Storage ambient temperature
Operating ambient humidity
Installation site
AC3 φ 200 V (60 Hz)
AC3 φ 220 V (60 Hz)
Power source breaker setting (A)
Mass (kg)
Standard coating color
Pump unit
Maximum discharge rate (Theoretical value; L/min) *1
Motor capacity (Equivalent kW)Motor capacity
Maximum operating pressure (MPa)
Operating flow rate adjustment range (L/min)
Operating pressure adjustment range (MPa)
Tank capacity (L)
Contact outputExternal
output signalDigital output
15.2
15.2
14.6
21.4
21.4
20.2
15.2
15.2
14.6
21.4
21.4
20.2
Tankless type Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
OIL
CO
OLI
NG
EQ
UIP
ME
NT
O
O-31
SUT00S1516-30SUT00S3016-30
SUT06S3016-30
SUT03S1516-30
Part No. Name Quantity
1-1 Inverter driven motor pump 1
1-2 Controller 1
2 AC fan 1
3 Base 1
Part No. Name Quantity
Part No. Name Quantity
6-1 Inverter driven motor pump 1
6-2 Controller 1
2 Suction strainer 1
3 Stop valve 1
4 Oil level gauge 1
5 Oil filler port with air breather 1
7 Oil cooler 1
1 Oil tank 1
8 AC fan 1
6-1 Inverter driven motor pump 1
6-2 Controller 1
2 Suction strainer 1
3 Stop valve 1
4 Oil level gauge 1
5 Oil filler port with air breather 1
7 Oil cooler 1
1 Oil tank 1
8 AC fan 1
9 Return filter 1
BoltCaution nameplate
SUT03S15L16-30Cleaning port tightening caution nameplate
Cleaning port tightening caution nameplate
BoltCaution nameplate
(Fitted with a vinyl cap at shipment)Rc⅜P
(Fitted with a vinyl cap at shipment)Rc⅜DR
Suction port: G¾
φ21 hole(Signal cable port)(Power cable port)
φ28 hole
φ21 hole(Signal cable port)
(Power cable port)φ28 hole
1-2
1-12
3
(137) (∗77)15578 (∗490)15
608 (∗520)
(202
)(294
)
1535
415
384
30548 (∗460)30
(260
)(2
45)
(109
)45
(133) (∗73)
3032430384
(45)
(421
)
608 (∗520)
(466
)
220
(∗ ): Dimensions for SUT00S1516-30
Optional port: Rp⅜
(Fitted with a vinyl cap at shipment)
Rc1T
(Fitted with a vinyl cap at shipment)Rc1T
(plugged at factory)Rc¾T
(Fitted with a vinyl cap at shipment)
Rp¾ (above oil level)DR
(Fitted with a vinyl cap at shipment)Rp¾ (above oil level)DR
Pressure indication and operation panel
Pressure indication and operation panel
Foundation plate (Option)(E-SUTPLATE-2)
Foundation plate (Option)(E-SUTPLATE-2)
(Fitted with a vinyl cap at shipment)Rc⅜P
(Fitted with a vinyl cap at shipment)Rc⅜P
(Manifold bracket mount)4-M8
(Manifold bracket mount)4-M8
3
23 LLower limit (Red line)
2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)
2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)
Oil sampling port/Oil drain port: Rc½
Oil sampling port/Oil drain port: Rc½
1
26-1
5 46-2
Optional port: Rp⅜
Optional port: Rp½
59 6-2
6-1
8
7
3
Cleaning port
4
2
1
70
20 10530
30 30 25
4020
59564
8
450500
70 155
(50)
8585
9530
9
639
700
(620)(40) (40)
100
50
170150186
(360
)
85 100
3711
042
70
20 10 30 30 25
4020
700530 8585
95
419 (5
16)
(620)186
140
4292
100
50
17015077.5
177.5132.5 550
(40) (40)
450500
70 155(50)
(309
) 462
Cleaning port
(Fitted with a vinyl cap at shipment)
(M8 bolts recommended)
4-φ10 holes (for fixing bolts)
(M12 bolts recommended)4-φ15 holes (for fixing bolts)
(M12 bolts recommended)4-φ15 holes (for fixing bolts)
8
7
Suction air
Suction air
Suction air
(To be removed before operation)
716
Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)
Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)
Optional port: Rp½
Safety caution nameplate
Unit nameplate
Safety caution nameplate
Unit nameplate
Safety caution nameplate
Unit nameplate
Pressure indication and operation panel
Wing bolt for fastening during transportation (at 1 location)
30 LUpper limit (Yellow line)
60 LUpper limit (Yellow line)45 LLower limit (Red line)
External dimension diagram
Tankless type
Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
O-32
Specifications
Pressure – Flow rate characteristics (Example)Maximum operating pressure 16 MPa
Maximum discharge rate 40 L/minModel code
Super Unit [Double pump type]
Pressure (MPa)
Flow
rate
(L/m
in)
0 5 10 15 200
10
20
30
40
50
60
70
80
90
100
110
* Operating flow rate at the maximum pressure in continuous operation:8 L/min maximum
* The graph shows actual flow rates (representative values).
SUT00D4016-30 SUT06D4016-30
17.7
16.5
53
1.5 to 15.7
15.7
5.4 to 41.0
Equivalent to 3.7 kW
3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
− 60
0 to 40°C
−20 to 60°C
85% RH max. (No condensation)
Indoors (Be sure to secure the unit with bolts.)
Ivory white (Munsell code 5Y7.5/1)
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.
1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)
Tankless type Unit type
41.0
5 channels
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
94
20
17.9
Model
External input signal
Motor pump/unitPower supply
AC3 φ 200 V (50 Hz)Rated current
(A)
Usable oil *2
Others
Operating conditions
Operating hydraulic oil temperature
Operating ambient temperature
Storage ambient temperature
Operating ambient humidity
Installation site
AC3 φ 200 V (60 Hz)
AC3 φ 220 V (60 Hz)
Power source breaker setting (A)
Mass (kg)
Standard coating color
Pump unit
Maximum discharge rate (Theoretical value; L/min) *1
Motor capacity (Equivalent kW)Motor capacity
Maximum operating pressure (MPa)
Operating flow rate adjustment range (L/min)
Operating pressure adjustment range (MPa)
Tank capacity (L)
Contact outputExternal
output signalDigital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
SUTD4016-30
Tankless type Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
OIL
CO
OLI
NG
EQ
UIP
ME
NT
O
O-33
SUT00D4016-30
SUT06D4016-30
Part No. Name Quantity
1-1 Inverter driven motor pump 1
1-2 Controller 1
2 AC fan 1
3 Base 1
4 Check valve 1
Part No. Name Quantity
6-1 Inverter driven motor pump 16-2 Controller 1
2 Suction strainer 13 Stop valve 14 Oil level gauge 15 Oil filler port with air breather 1
7 Oil cooler
1 Oil tank 1
8 AC fan 19 Return filter 1
110 Check valve
1
Cleaning port tightening caution nameplate
(620) (40)(40)
70
20 10
700530
30 30 25
4020
59564
8
450500
70 155(50)
639 71
6
3711
0
42
8585
95(4
41)
100
50
170150
(309
)
194.5320.510085
BoltCaution nameplate
Pressure indication and operation panelUnloading port Rc½(Fitted with a vinyl cap at shipment)
(Fitted with a vinyl cap at shipment)
P
(Fitted with a vinyl cap at shipment)
Rc⅜
(Fitted with a vinyl cap at shipment)
DR
Rc¾
1-2
1-1
4
6083054830
Suction port: Rc1
(142)1557815
608
(95)
(180
)(7
3)
(146)
(294
)15
354
1538
4
(93)
(149)
(95)
(226
)(2
82)
45
220
(466
)
2
330 324 30
384
45(4
21)
(Fitted with a vinyl cap at shipment)
Rc1T
(Fitted with a vinyl cap at shipment)Rp¾ (above oil level)DR
Optional port: Rp⅜
Optional port: Rp½
(plugged at factory)Rc¾T
(Manifold bracket mount)4-M8
(Fitted with a vinyl cap at shipment)
Rc¾P
Foundation plate (Option)(E-SUTPLATE-2)Pressure indication and operation panel
3
59 106-2
6-1
Oil sampling port/Oil drain port: Rc½
60 LUpper limit (Yellow line)
45 LLower limit (Red line)
4
2
1
Cleaning port
2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)
φ21 hole(Signal cable port)(Power cable port)
φ28 hole
(M8 bolts recommended)4-φ10 holes (for fixing bolts)
(M12 bolts recommended)
4-φ15 holes (for fixing bolts)
Suction air
8
7
Suction air
Wing bolt for fastening during transportation (at 1 location)
(To be removed before operation)
Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)
Safety caution nameplate
Unit nameplate
Safety caution nameplate
Unit nameplate
External dimension diagram
Tankless type
Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
O-34
Specifications
Pressure – Flow rate characteristics (Example)Maximum operating pressure 21 MPa
Maximum discharge rate 60 L/minModel code
Super Unit [Double pump type]
Pressure (MPa)
Flow
rate
(L/m
in)
0 5 10 15 200
10
20
30
40
50
60
70
80
90
100
110
* Operating flow rate at the maximum pressure in continuous operation:6.5 L/min maximum
* The graph shows actual flow rates (representative values).
SUT00D6021-30 SUT06D6021-30 SUT10D6021-30
21.7
20.2
58 99 112
1.5 to 20.6
20.6
8.7 to 61.1
Equivalent to 5.0 kW
3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
− 60 100
0 to 40°C
−20 to 60°C
85% RH max. (No condensation)
Indoors (Be sure to secure the unit with bolts.)
Ivory white (Munsell code 5Y7.5/1)
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.
1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)
2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
Tankless type Unit type
61.1
5 channels
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
30
22.1
Model
External input signal
Motor pump/unitPower supply
AC3 φ 200 V (50 Hz)Rated current
(A)
Usable oil *2
Others
Operating conditions
Operating hydraulic oil temperature
Operating ambient temperature
Storage ambient temperature
Operating ambient humidity
Installation site
AC3 φ 200 V (60 Hz)
AC3 φ 220 V (60 Hz)
Power source breaker setting (A)
Mass (kg)
Standard coating color
Pump unit
Maximum discharge rate (Theoretical value; L/min) *1
Motor capacity (Equivalent kW)Motor capacity
Maximum operating pressure (MPa)
Operating flow rate adjustment range (L/min)
Operating pressure adjustment range (MPa)
Tank capacity (L)
Contact outputExternal
output signalDigital output
SUTD6021-30
Tankless type Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
OIL
CO
OLI
NG
EQ
UIP
ME
NT
O
O-35
SUT00D6021-30
SUT06D6021-30
SUT10D6021-30
Part No. Name Quantity
6-1 Inverter driven motor pump 1
6-2 Controller 1
2 Suction strainer 1
3 Stop valve 1
4 Oil level gauge 1
5 Oil filler port with air breather 1
7 Oil cooler 1
1 Oil tank 1
8 AC fan 1
9 Return filter 1
10 Check valve 1
Part No. Name Quantity
6-1 Inverter driven motor pump 1
6-2 Controller 1
2 Suction strainer 1
3 Stop valve 1
4 Oil level gauge 1
5 Oil filler port with air breather 1
7 Oil cooler 1
1 Oil tank 1
8 AC fan 1
9 Return filter 1
10 Check valve 1
Part No. Name Quantity
1-1 Inverter driven motor pump 1
1-2 Controller 1
2 AC fan 1
3 Base 1
4 Check valve 1
Cleaning port tightening caution nameplate
BoltCaution nameplate
Cleaning port tightening caution nameplate
BoltCaution nameplate
(136) 1557815608
Pressure indication and operation panel
(294
)
1535
415
384
(Fitted with a vinyl cap at shipment)Rc¾P
(Fitted with a vinyl cap at shipment)Unloading port Rc½
(Fitted with a vinyl cap at shipment)Rc⅜DR
1-2
1-1
2
3
608
3032430384
(45)
(421
)
45
(466
)
(86)
(142.5)
(95)
(226
)(2
82)
(95)
(73)
(180
)
(140)
Optional port: Rp⅜
Optional port: Rp½
(Fitted with a vinyl cap at shipment)Rc1T (Fitted with a vinyl cap at shipment)
Rp¾ (above oil level)DR
Foundation plate (Option)(E-SUTPLATE-2)
(Fitted with a vinyl cap at shipment)Rc¾P
(Manifold bracket mount)4-M8
(620)(40) (40)
2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)
Oil sampling port/Oil drain port: Rc½
Cleaning port
4
4
2
1
450500
70 155
(50)
639
716
716
59 6-2
6-1
8
7
8
7
10
3
(309
)
3711
042
100
50
17015018832710085
70
20 10530
30 30 25
4020
59564
8
8585
95(4
41)
700
Optional port: Rp⅜
Optional port: Rp½
(Fitted with a vinyl cap at shipment)
Rc1T
(plugged at factory)Rc¾T
(plugged at factory)Rc¾T
(Fitted with a vinyl cap at shipment)Rp¾ (above oil level)DR 170150
18832710085
(Manifold bracket mount)4-M8
100
50
(439
)
Foundation plate (Option)(E-SUTPLATE-2)
(Fitted with a vinyl cap at shipment)Rc¾P
(620)(40) (40)
3
2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)
59 6-2
6-1
10
70
20 10530
30 30
4020
59564
8
8585
95(4
41)
700
25 450
70 155
Cleaning port
2
1
639
(50)
Oil sampling port/Oil drain port: Rc½
4
50 80580630
167
110
172
φ21 hole(Signal cable port)(Power cable port)
φ28 hole (M8 bolts recommended)4-φ10 holes (for fixing bolts)
(M12 bolts recommended)4-φ15 holes (for fixing bolts)
(M12 bolts recommended)4-φ15 holes (for fixing bolts)
Suction air
Suction air
Suction air
Wing bolt for fastening during transportation (at 1 location)
(To be removed before operation)
Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)
Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)
(Fitted with a vinyl cap at shipment)
Suction port: Rc1
Safety caution nameplate
Safety caution nameplate
Unit nameplate
(241
)
Unit nameplate
Unit nameplate60 LUpper limit (Yellow line)45 LLower limit (Red line)
100 LUpper limit (Yellow line)76 LLower limit (Red line)
Safety caution nameplate
External dimension diagram
Tankless type
Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
O-36
Specifications
Pressure – Flow rate characteristics (Example)Maximum operating pressure 21 MPa
Maximum discharge rate 80 L/minModel code
Super Unit [Double pump type]
Pressure (MPa)
Flow
rate
(L/m
in)
0 5 10 15 200
10
20
30
40
50
60
70
80
90
100
110
* Operating flow rate at the maximum pressure in continuous operation:14 L/min maximum
* The graph shows actual flow rates (representative values).
SUT00D8021-30 SUT10D8021-30 SUT16D8021-30
50
25.5
24.8
22.7
72 133 145
1.5 to 20.6
20.6
11.6 to 83.0
Equivalent to 7.0 kW
3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
− 100 160
0 to 40°C
−20 to 60°C
85% RH max. (No condensation)
Indoors (Be sure to secure the unit with bolts.)
Ivory white (Munsell code 5Y7.5/1)
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.
1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A (Resistance load)
Tankless type Unit type
83.0
5 channels
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
Model
External input signal
Motor pump/unitPower supply
AC3 φ 200 V (50 Hz)Rated current
(A)
Usable oil *2
Others
Operating conditions
Operating hydraulic oil temperature
Operating ambient temperature
Storage ambient temperature
Operating ambient humidity
Installation site
AC3 φ 200 V (60 Hz)
AC3 φ 220 V (60 Hz)
Power source breaker setting (A)
Mass (kg)
Standard coating color
Pump unit
Maximum discharge rate (Theoretical value; L/min) *1
Motor capacity (Equivalent kW)Motor capacity
Maximum operating pressure (MPa)
Operating flow rate adjustment range (L/min)
Operating pressure adjustment range (MPa)
Tank capacity (L)
Contact outputExternal
output signalDigital output 2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
SUTD8021-30
Tankless type Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
OIL
CO
OLI
NG
EQ
UIP
ME
NT
O
O-37
SUT00D8021-30
Part No. Name Quantity
1-1 Inverter driven motor pump 1
1-2 Controller 1
2 AC fan 1
3 Base 1
4 Check valve 1
SUT10D8021-30SUT16D8021-30
Part No. Name Quantity
6-1 Inverter driven motor pump 16-2 Controller 1
2 Suction strainer 13 Stop valve 14 Oil level gauge 15 Oil filler port with air breather 1
7 Oil cooler
1 Oil tank 1
8 AC fan 19 Return filter 1
110 Check valve
1
Transportation nameplate
Motor cable
294
15
384
354
15
(60) 630600
(97)
15 15
(Fitted with a vinyl cap at shipment)Unloading port: Rc½
(139)
(125
) (196
)
483
258
3
2
4
(To be removed before operation)
Wing bolt for fastening during transportation (at 2 locations)
(142)
30 30570
(299
)
(90)
(408
)
(311
)
(72)
45(4
41)
30 324 30
(M8 bolts recommended)4-φ10 holes (for fixing bolts)
(M12 bolts recommended)4-φ15 holes (for fixing bolts)
Cleaning port tightening caution nameplate
BoltCaution nameplate
(Fitted with a vinyl cap at shipment)Rc⅜DR
(Fitted with a vinyl cap at shipment)Rc¾P
1-1
1-2
(Plugged (with O-ring) at shipment)Suction port: Rc1
Pressure indication and operation panel
(620) (40)(40)
(Fitted with a vinyl cap at shipment)Rc¾P
Foundation plate (Option)(E-SUTPLATE-2)
Optional port: Rp⅜
Optional port: Rp½
(Fitted with a vinyl cap at shipment)
Rc1-½T
(plugged at factory)Rc1-¼T
(Fitted with a vinyl cap at shipment)
Rp¾ (above oil level)DR
(Manifold bracket mount)4-M8
(∗ ): Dimensions for SUT10D8021-30
2-M8 (through hole)Tapped holes for mounting the foundation plate (at 4 locations)
Wing bolt for fastening during transportation (at 1 location on the back)(To be removed before operation)
3
59
106-2
6-18
7
Oil sampling port/Oil drain port: Rc½
164 L (∗100 L)Upper limit (Yellow line)
124 L (∗76 L)Lower limit (Red line)
4
2
1
170150
50
100
32710085 188700
1715
0
382
(∗17
2)
(649
) (∗4
39)
70
10
700530 25
4020
595
208585
95(4
41)
30 30
671
(216
)
(893.5)188.5
Cleaning port
70 155
(50)
(647
) 754
450 50 290 (∗80)790 (∗580)840 (∗630)
Suction air
Suctionair
Safety caution nameplate
Unit nameplate
Safety caution nameplate
Unit nameplate
External dimension diagram
Tankless type
Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
O-38
Specifications
Pressure – Flow rate characteristics (Example)Maximum operating pressure 21 MPa
Maximum discharge rate 110 L/minModel code
Super Unit [Double pump type]
Pressure (MPa)
Flow
rate
(L/m
in)
0 5 10 15 200
10
20
30
40
50
60
70
80
90
100
110
* Operating flow rate at the maximum pressure in continuous operation:16 L/min maximum
* The graph shows actual flow rates (representative values).
SUT00D11021-30 SUT20D11KW-30
37.8
34.9
112 360
1.5 to 20.6
20.6
13.3 to 110
3-phase, 200 V (50 Hz), 200 V (60 Hz), 220 V (60 Hz) (Permissible voltage fluctuation: ±10%)
0 to 60°C (Recommended operating temperature range: 15 to 50°C)
− 200
0 to 40°C
−20 to 60°C
85% RH max. (No condensation)
Indoors (Be sure to secure the unit with bolts.)
Ivory white (Munsell code 5Y7.5/1)
Photo-coupler insulation, DC 24 V (DC 27 V maximum), 5 mA/channel
Special mineral-oil base hydraulic oil/wear-resistant hydraulic oil• Viscosity grade: ISO VG32 to 68 • Viscosity range: 15 to 400 mm2/s • Contamination: Within NAS class 9 • Volumetric water content: 0.1% maximum
• Be sure to connect a circuit breaker for all (three) poles and the earth leakage breaker.• Make sure that the electrical wiring meets the requirements of European Standard EN60204-1.• Frequent turning this unit’s power supply ON/OFF will considerably shorten the control unit’s service life.
To start or stop the unit at 8-minute or shorter intervals, use the unit’s control stop function.• Be sure to connect the ground terminal.
1 channel (1 common contact), dry contact, Contact capacity: DC 30 V, 0.5 A
2 channels, photo coupler insulation, FET output, DC 24 V, 50 mA maximum per channel
Tankless type Unit type
110
5 channels
Note) *1: The pump flow rate has been factory-set to the maximum discharge rate. The maximum discharge rate given in the table above is a theoretical value, not a guaranteed value.*2: Consult Daikin about the use of hydraulic oils other than mineral-oil base type (e.g. hydrous/synthetic) such as water-glycol hydraulic oil.*3: The unit incorporates a safety valve.*4: When selecting a Super Unit, refer to “Pressure-Flow rate characteristics” and the description of how to select a unit in the separate catalog for Super Units. For the purpose of making improvements, the specifications given in catalogs are subject to change without prior notice. Be sure to refer to the latest outside drawing.
75
38.3
Equivalent to 11 kW
Model
External input signal
Motor pump/unitPower supply
AC3 φ 200 V (50 Hz)Rated current
(A)
Usable oil *2
Others
Operating conditions
Operating hydraulic oil temperature
Operating ambient temperature
Storage ambient temperature
Operating ambient humidity
Installation site
AC3 φ 200 V (60 Hz)
AC3 φ 220 V (60 Hz)
Power source breaker setting (A)
Mass (kg)
Standard coating color
Pump unit
Maximum discharge rate (Theoretical value; L/min) *1
Motor capacity (Equivalent kW)Motor capacity
Maximum operating pressure (MPa)
Operating flow rate adjustment range (L/min)
Operating pressure adjustment range (MPa)
Tank capacity (L)
Contact outputExternal
output signalDigital output
SUT00D11021-30P-SUT20D11KW-30
Tankless type Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
OIL
CO
OLI
NG
EQ
UIP
ME
NT
O
O-39
SUT00D11021-30
P-SUT20D11KW-30
151
819
Motor wiring port (φ28)
AC fan, thermistor wiring port (21)
134
Rc⅜
Suction port: Rc1 ¼
Drain port
11842
168
323
19
199
Unloading portRc¾
170
76.5
496
112
207 24
3
4-14.5 (installation)
228275
132.595.5
170
Discharge portRc1−¼
314
117 204
228
108108
241
15
237
12090
Lower limit: 165 L
(982
)(1
0)60
035
2
1,3762881,088
43 431,002
9
210
850
11
2
1
146
Tank 2: Rc1(Fitted with plastic plug)Drain port: Rc¾
(Fitted with plastic plug)
(Fitted with high-pressure plug)Tank drain port: Rc½ (at 3 locations)
Upper limit: 200 L
838544
Discharge port: Rc1(Fitted with plastic plug)(Fitted with plastic plug)
Tank 1: Rc1-½
942
210
920
155
866
300
1,15
0 Oil level gauge guard
200 L
Super Unit switch board
Safety caution nameplate
OIL HYDRAULIC UNIT
Unit nameplate
Thermometer
DAIKINDAIKIN INDUSTRIES,LTD. MADE IN JAPAN
DAIKIN
G1/2
670 250
80
Leak test by filling waterCertificate nameplate
Wiring port for the user
137
810
5
4
Part No. Name Quantity1 Oil tank 12 Motor pump 13 Oil level gauge 24 Oil filler port with air breather 15 Suction strainer 16 Return filter7 Oil cooler 18 Pressure gauge 19 Thermometer 1
110 Outlet block611 Vibration-absorbing rubber112 Foundation plate113 Fan motor114 Electrical cabinet
1
3
3
Suction air
Suction air
(Refer to Page O-25 for the external dimensions of the control unit.)
External dimension diagram
Tankless type
Unit type
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
O-40
Optional parts
The following optional parts can be purchased separately from the Super Unit.These parts are to be mounted by the user.
Base plate setThese parts are used to fasten the Super Unit to a floor surface. The bolts for mounting the unit to the floor should be prepared by the user.
Color AccessoriesModel
E-SUTPLATE-2
Applicable model
[Unit type: Single pump type] SUT03S1507-30 SUT03S3007-30 SUT06S6007-30 SUT10S8007-30 SUT03S1510-30 SUT03S3010-30 SUT03S1516-30 SUT03S4007-30 SUT06S3016-30[Unit type: Double pump type] SUT06D4016-30 SUT06D6021-30 SUT10D6021-30 SUT10D8021-30 SUT16D8021-30
Temperature switchMountsize
Rp ⅜ N/A
Model code
IP65 60°C2 A50 mA
AC100 VDC24 V
25
2-C3
25
2510 30 10
5040
40t3.2
2-C3
25
Level switchMountsizeModel code
E-DLSN-90L-A-10
Rp ½
EHUR-M0701 7 L maximum ClosedE-DLSN-90L-B-10 EHUR-M0701 7 L maximum Open
E-DLSN-170L-A-10SUT06 (with 60 L tank)SUT10 (with 100 L tank)SUT16 (with 160 L tank)
E-DLSN-170L-B-10SUT06 (with 60 L tank)SUT10 (with 100 L tank)SUT16 (with 160 L tank)
ClosedClosedClosed
OpenOpenOpen
E-DLSN-130L-A-10
IP651 Ωmaximum
30 mΩmaximum
0.02A0.05A
AC100/110VDC24V
EHU14/25/30EHUR-M0702SUT03 (with 30 L tank)SUT06 (with 60 L tank)SUT10 (with 100 L tank)SUT16 (with 160 L tank)
E-DLSN-130L-B-10
EHU14/25/30EHUR-M0702SUT03 (with 30 L tank)SUT06 (with 60 L tank)SUT10 (with 100 L tank)SUT16 (with 160 L tank)
45 L maximum75 L maximum
123 L maximum45 L maximum75 L maximum
123 L maximum
7.3 L maximum13L L maximum21 L maximum50 L maximum83 L maximum
135 L maximum7.3 L maximum13 L maximum21 L maximum50 L maximum83 L maximum
135 L maximum
ClosedClosedClosedClosedClosedClosed
OpenOpenOpenOpenOpenOpen
N/A
ThermometerSizeModel code Temperature
indication range
0 to 100°C φ45
Thermometerspecification
Bimetal type
List of Compatible ModelsModel code EHUR-M0701-30
Micro separator
E-MSB-110
Model Size
110×60×30
E-DLSN-90L-A-10 *4E-DLSN-90L-B-10E-DLSN-130L-A-10E-DLSN-130L-B-10E-DLSN-170L-A-10E-DLSN-170L-B-10E-MQT83PD-L60X1-1-10E-MQT83PD-L60X1-10E-RBT-100-100LE-RBT-100-200LE-MSB-110
Level switch
Temperatureswitch
Thermometer
Micro separator
−
EHUR-M0702-30
−
SUT03S-30
−
SUT06-30
−
SUT10-30
−
SUT16D-30
*4 − − − − −− *4 *7 − − −
*5 − − − − −− *5 *8 *8 *8 *8*6 −− − − − −− *6 *9 *9 *9 *9
− *4*1*1 *7 − − −
*7 *7 *7− − −*7 *7 *7−
EHU14/25/30
−−
−*2
*3
−− − −
Example of installation
E-MQT83PD-L60X1-1-10E-MQT83PD-L60X1-10
E-RBT-100-100LE-RBT-100-200L
Note: *1. Mounted directly at the DR2 port *2. Mounted at the DR1 port with a low-pressure or high-pressure bushing (1 × ⅜) or at the DR2 port with a low-pressure or high-pressure bushing (½ × ⅜) *3. Mounted at the DR2 port with a low-pressure or high-pressure bushing (½ × ¼) *4. Mounted at the DR2 port with a high-pressure bushing (¾ × ½) *5. Mounted at the DR2 port with a low-pressure or high-pressure bushing (¾ × ⅜) *6. Mounted at the DR2 port with a low-pressure or high-pressure bushing (¾ × ¼) *7. Mounted directly at option port Rp½ *8. Mounted directly at option port Rp⅜ *9. Mounted at option port Rp⅜ with a low-pressure or high-pressure bushing (⅜ × ¼)
Ivory whiteMunsell code
5Y7.5/1
Base plate (4 pcs)
Tank fastening bolt (8 pcs)
Plain and spring washers for the above parts (8 pcs each)
Oil level triggering alarms CE standard
Protection class
Contactresistance
Operatingcurrent
Operating voltage
Base plate dimensions
φ15 hole
2-φ10 holes
Oil level triggering alarms CE standardProtection class
Contact resistance
Operating current
Operating voltage
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
OIL
CO
OLI
NG
EQ
UIP
ME
NT
O
O-41
Optional parts
Model code
SUT03S1507-30SUT03S1510-30SUT03S1516-30SUT03S3007-30SUT03S3010-30SUT03S4007-30SUT06S3016-30SUT06S6007-30SUT06D4016-30SUT06D6021-30SUT10D6021-30SUT10S8007-30SUT10D8021-30SUT16D8021-30
Tank capacity
Super Unit
30 L
60 L
100 L
160 L
Return filter
Not provided
Provided
Tank capacity
30 L
60 L
100 L
160 L
Return filter
Not provided
Provided
Manifold bracket
Model code
Piping set
Installation of 02 Size Control Systems
Model code
E-SUT03S1507N-PIPE-02E-SUT03S1510N-PIPE-02E-SUT03S1516N-PIPE-02E-SUT03S3007N-PIPE-02E-SUT03S3010N-PIPE-02E-SUT03S4007N-PIPE-02E-SUT06S3016F-PIPE-02E-SUT06S6007F-PIPE-02E-SUT06D4016F-PIPE-02E-SUT06D6021F-PIPE-02E-SUT10D6021F-PIPE-02E-SUT10S8007F-PIPE-02E-SUT10D8021F-PIPE-02E-SUT16D8021F-PIPE-02
Part Configuration
Manifold bracket
Model code
Piping set
Model code Part Configuration
(1)
(2)
(3)
Model code
SUT03S1507-30SUT03S1510-30SUT03S1516-30SUT03S3007-30SUT03S3010-30SUT03S4007-30SUT06S3016-30SUT06S6007-30SUT06D4016-30SUT06D6021-30SUT10D6021-30SUT10S8007-30SUT10D8021-30SUT16D8021-30
Super Unit
E-SUT03BASE-203 (Maximum installable series : 2)[Mountable manifold blocks]BT-103-40 (1 series), BT-203-40 (2 series)
E-SUT06BASE-203 (Maximum installable series : 2)[Mountable manifold blocks]BT-103-40 (1 series), BT-203-40 (2 series)
E-SUT06BASE-403 (Maximum installable series : 4)[Mountable manifold blocks]BT-103-40 (1 series) to BT-403-40 (4 series)
Installation of 03 Size Control Systems
E-SUT03S1507N-PIPE-03E-SUT03S1510N-PIPE-03E-SUT03S1516N-PIPE-03E-SUT03S3007N-PIPE-03E-SUT03S3010N-PIPE-03E-SUT03S4007N-PIPE-03E-SUT06S3016F-PIPE-03E-SUT06S6007F-PIPE-03E-SUT06D4016F-PIPE-03E-SUT06D6021F-PIPE-03E-SUT10D6021F-PIPE-03E-SUT10S8007F-PIPE-03E-SUT10D8021F-PIPE-03E-SUT16D8021F-PIPE-03
(1)
(2)(3)
(4)
(3)
E-SUT03BASE-402E-SUT06BASE-302E-SUT06BASE-602E-SUT03BASE-203E-SUT06BASE-203E-SUT06BASE-403
Model code Maximum installable series
4-series3-series6-series2-series2-series4-series
Accessories
- Bracket body 1 pc- Hexagon bolt (M8 × 16) 4 pcs- Flat washer (M8) 4 pcs
For mounting the manifoldHexagon socket head cap bolt, 2 pcs(M8 × 85)
For mounting the manifoldHexagon socket head cap bolt, 4 pcs(M8 × 105)
Bracket/Piping Set for Manifolds
Component parts Manifold bracket
In order to install a control system on the Super Unit, select a bracket and piping set for the manifold according to the control system’s size and number of series. Please prepare a manifold block separately.
E-SUT03BASE-402 (Maximum installable series: 4)[Mountable manifold blocks]BT-102-50 (1 series) to BT-402-50 (4 series) or BT-102-50-140 (1 series) to BT-402-50-140 (4 series)
E-SUT06BASE-302 (Maximum installable series: 3)[Mountable manifold blocks]BT-102-50 (1 series) to BT-302-50 (3 series) or BT-102-50-140 (1 series) to BT-302-50-140 (3 series)
E-SUT06BASE-602 (Maximum installable series: 6)[Mountable manifold blocks]BT-102-50 (1 series) to BT-602-50 (6 series) or BT-102-50-140 (1 series) to BT-602-50-140 (6 series)
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
O-42
Optional parts
Piping set
For installing 02 size control systems For installing 03 size control systems
For installing 03 size control systems
1Part Configuration
2Part Configuration
3
2
1
4
8
756
* The external shape differs depending on the model.
* The external shape differs depending on the model.
Name Quantity Tightening torque (N⋅m)
E-SUT03S1507N-PIPE-02E-SUT03S1510N-PIPE-02E-SUT03S1516N-PIPE-02E-SUT03S3007N-PIPE-02E-SUT03S3010N-PIPE-02
Model codeHydraulic hose 1 54.0 to 66.0Hose adaptor (straight) 1 43.0 to 47.5Hose adaptor (elbow) 1 43.0 to 47.5― ― ―Steel pipe 1 100.0 to 120.0Steel piping joint (straight) 1 28.5 to 33.0Steel piping joint (elbow) 1 28.5 to 33.0Bushing 1 95.0 to 110.0Installation guide 1 ―
123456789
E-SUT03S4007N-PIPE-02
Hydraulic hose 1 54.0 to 66.0Hose adaptor (straight) 1 64.0 to 70.0Hose adaptor (elbow) 1 43.0 to 47.5― ― ―Steel pipe 1 100.0 to 120.0Steel piping joint (straight) 1 28.5 to 33.0Steel piping joint (elbow) 1 28.5 to 33.0Bushing 1 95.0 to 110.0Installation guide 1 ―
123456789
Name Quantity Tightening torque (N⋅m)
E-SUT03S1507N-PIPE-03E-SUT03S1510N-PIPE-03E-SUT03S1516N-PIPE-03E-SUT03S3007N-PIPE-03E-SUT03S3010N-PIPE-03
Model codeHydraulic hose 1 54.0 to 66.0Hose adaptor (straight) 1 43.0 to 47.5Hose adaptor (elbow) 1 64.0 to 70.0Bushing
―
Steel pipe 1 247.0 to 286.01 110.0 to 120.0
Steel piping joint (straight) 1 95.0 to 110.0Steel piping joint (elbow) 1 57.0 to 66.0― ―Installation guide 1 ―
123456789
Hydraulic hose 1 108.0 to 132.0Hose adaptor (straight) 1 64.0 to 70.0Hose adaptor (elbow) 1 110.0 to 120.0
― ―
―
Steel pipe 1 247.0 to 286.0Steel piping joint (straight) 1 95.0 to 110.0Steel piping joint (elbow) 1 57.0 to 66.0―
―
―Installation guide 1 ―
123456789
E-SUT03S4007N-PIPE-03
Name Quantity Tightening torque (N⋅m)
E-SUT06S3016F-PIPE-02
Model codeHydraulic hose 1 54.0 to 66.0Hose adaptor (straight) 1 43.0 to 47.5Hose adaptor (elbow) 1 43.0 to 47.5― ― ―
― ― ―
Steel pipe 1 100.0 to 120.0Steel piping joint (elbow) 2 28.5 to 33.0Bushing 1 57.0 to 66.0Plug 1 95.0 to 110.0Installation guide 1 ―
123456789
Steel piping joint (elbow) 2 95.0 to 110.0
Plug 1 95.0 to 110.0Installation guide 1 ―
6789
Name Quantity Tightening torque (N⋅m)
E-SUT06S3016F-PIPE-03
Model codeHydraulic hose 1 54.0 to 66.0Hose adaptor (straight) 1 43.0 to 47.5Hose adaptor (elbow) 1 64.0 to 70.0BushingSteel pipe 1 247.0 to 286.0
1 110.0 to 120.0
12345
3
2
6
5
7
Mounted in the port at the back of the return filter
4
8
61
For installing 02 size control systems
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
OIL
CO
OLI
NG
EQ
UIP
ME
NT
O
O-43
Optional parts
Piping set
For installing 02 size control systems
For installing 03 size control systems
For installing 03 size control systems
3Part Configuration
4Part Configuration
* The external shape differs depending on the model.
* The external shape differs depending on the model.
Name Quantity Tightening torque (N⋅m)
E-SUT06S6007F-PIPE-02E-SUT06D4016F-PIPE-02E-SUT06D6021F-PIPE-02E-SUT10D6021F-PIPE-02
Model codeHydraulic hose 1 54.0 to 66.0Hose adaptor (straight) 1 64.0 to 70.0Hose adaptor (elbow) 1 43.0 to 47.5
― ― ―
High-pressure bushing 1 110.0 to 120.0Steel pipe 1 100.0 to 120.0Steel piping joint (elbow) 2 28.5 to 33.0Low-pressure bushing 1 57.0 to 66.0
95.0 to 110.0Plug 1
123456789
E-SUT10S8007F-PIPE-02E-SUT10D8021F-PIPE-02E-SUT16D8021F-PIPE-02
Hydraulic hose 1 54.0 to 66.0Hose adaptor (straight) 1 43.0 to 47.5Hose adaptor (elbow) 1 43.0 to 47.5
Steel pipe 1 100.0 to 120.0Steel piping joint (elbow) 2 28.5 to 33.0Low-pressure bushing (small) 1 57.0 to 66.0
142.5 to 165.0Low-pressure bushing (large) 1 114.0 to 132.0
High-pressure bushing 1 110.0 to 120.0
Plug 1
123456789
Installation guide 1 ―10
Name Quantity Tightening torque (N⋅m)
E-SUT06S6007F-PIPE-03E-SUT10D6021F-PIPE-03
Model codeHydraulic hose 1 108.0 to 132.0Hose adaptor (straight) 1 110.0 to 120.0Hose adaptor (elbow) 1 110.0 to 120.0
―
Steel pipe 1 247.0 to 286.0Steel piping joint (elbow) 2 57.0 to 66.0
95.0 to 110.0― ―
―― ―
―― ―
Plug 1
123456789
Installation guide 1 ―10 Installation guide 1 ―10
Hydraulic hose 1 108.0 to 132.0Hose adaptor (straight) 1 110.0 to 120.0Hose adaptor (elbow) 1 110.0 to 120.0― ― ―
―
Steel pipe 1 247.0 to 286.0Steel piping joint (elbow) 2 57.0 to 66.0Bushing 1 114.0 to 132.0
142.5 to 165.0― ―Plug 1
123456789
Installation guide 1 ―10
E-SUT10S8007F-PIPE-03E-SUT10D8021F-PIPE-03E-SUT16D8021F-PIPE-03
Name Quantity Tightening torque (N⋅m)
E-SUT06D4016F-PIPE-03E-SUT06D6021F-PIPE-03
Model codeHydraulic hose 1 108.0 to 132.0Hose adaptor (elbow) 2 110.0 to 120.0Female-male elbow 1 110.0 to 120.0
Steel piping joint (elbow) 2 57.0 to 66.0Steel pipe 1 247.0 to 286.0
Plug 1 95.0 to 110.0Installation guide 1 ―
1234567
6
3
7
2
4
8
6
95
1
Mounted in the port at the back of the return filter
4
5
2
3
2
15
6 Mounted in the port at the back of the return filter
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
O-44
Handling
Ambient conditions
Hydraulic oil
Installation and piping
Electric wiring
Other precautions
The following are the minimum requirements for use of the Super Unit.For details, refer to the unit’s Instruction Manual.
1. Use general petroleum hydraulic oil (R&O) or wear-resistant hydraulic oil.Hydrous or synthetic oil cannot be used.
2. Use hydraulic oil equivalent to ISO VG32 to 68 and operate the unit within an oil viscosity range from 15 to 400 mm2/s and a tank oil temperature from 0 to 60°C. The recommended operating range is from 15 to 50°C (20 to 200 mm2/s).
3. Ensure the degree of contamination of the hydraulic fluid is within the NAS 9 class (within NAS 10 class for 7 MPa and lower).
1. Ambient temperature: 0 to 40°C, ambient humidity: 85%RH maximum (with no condensation), altitude: 1,000 m maximum, to be used indoors
1. This hydraulic unit mounts the motor pump using vibration-absorbing rubber to prevent pump vibration being transmitted to the unit.
2. The unit is a stationary type. Fix it with bolts on a level location that is free of vibration.3. Keep obstacles that will obstruct air intake and emission at least 100 mm away from the end face of the unit.
Install the unit at a location with good air flow so that heated air can be vented.4. Use hoses for piping to provide flexibility.5. Before operating the unit, be sure to remove the wing bolt and spacer for protecting the rubber vibration isolator.
If you fail to do so, the noise and vibration may be excessive.6. Be sure to secure the space required to access the unit during electrical wiring at the noise filter box or control unit
side.
1. Install a no-fuse breaker and a ground fault interrupter compliant with European Standard EN60947-2 in the main power supply of this hydraulic unit, to protect the electrical circuits against shorting and overcurrent, and to prevent electric shocks.
2. Use suitable electric cable in accordance with the power supply capacity.3. Be sure to provide a ground connection with a grounding resistance of 100 Ω maximum, and connect the grounding
wire directly with no breaker in the line.4. Take care not to leave waste metal such as screws and cutting chips, combustible matter such as wood waste or
oil, or wiring debris inside the controller.5. Use a commercial power supply for the power source. The use of an inverter power supply may cause burn damage
to the unit.6. Before accessing the interior of the controller, turn the unit’s power supply OFF. Make sure that the circuit is turned
OFF using the circuit breaker for the primary power supply, and then wait at least 5 minutes.
1. If a failure occurs in the hydraulic unit, the system indicates an alarm and stops.2. If failure or malfunction of this unit is expected to cause death or pose a danger to human beings, adopt appropriate
safety measures in the facilities. If this unit is used in an important facility, also adopt appropriate safety measures in the facility to ensure that a failure of the equipment will not lead to a serious accident or loss.
3. It takes approximately 3 seconds for this hydraulic unit to start up after being powered ON.Depending on the piping conditions, the unit may take longer to increase the pressure to the pressure switch&squot;s preset level, resulting in pressure switch signal output. In this case, set the machine up so that it will not accept this alarm output during this period.
4. Do not turn the power OFF/ON with the main power breaker frequently. It may damage inverter components.(To start and stop the unit, use the start/stop signal.)
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
InternetContact DetailsBefore using the product, please check the guide pages at the front of this catalog.
http://www.daikinpmc.com/en/For latest information, PDF catalogs and operation manuals
OIL
CO
OLI
NG
EQ
UIP
ME
NT
O
O-45
Overview of Super Unit Model Change Transition Points
Design No.
Design No. 10 Design No. 11 Design No. 20 Design No. 30
Spe
cific
atio
ns
Paint color
With 3.7 to 5.0 kW tank
Blue (Munsell code 10B3/8)
Ivory white (Munsell code 5Y7.5/1)
Other than aboveIvory white
(Munsell code 5Y7.5/1)
Operating ambient temperature 0 to 35°C 0 to 40°C
Power supply2.2 to 5.0 kW Three-phase AC200/220 V
Single phase AC230 V also available with non-standard types
(However, the pressure – flow rate range contracts.)
Other than above Three-phase AC200/220V Three-phase AC200/220V only
Multi-stage pressure/flow rate control
3.7 to 5.0 kW 4-pattern16-pattern
Other than above 16-pattern
Communication functions
3.7 to 5.0 kW RS485 available with non-standard types RS232C is set as an option.RS485/RS422, etc., are available
with non-standard types.Other than above RS232C option setting
Separation of power supplies for the power system and control system
2.2 to 7.0 kW No separation Optionally available
Other than above No separation
Compliance with CE2.2 to 2.8 kW Available with non-standard types
Available with all modelsOther than above Not available
Analog I/O control Available with non-standard typesOptionally available with all single
pump modelsOptionally available
Improved environmental resistance performance
11 kW Available with non-standard types Electronic parts compatible with sulfides adopted for all modelsOther than above Not available
Unit external dimensions - Approximately the same
Unit cover
With 3.7 to 5.0 kW tank Equipped as standardEquipped as standard
(discharge position changed)Optionally available
With 7.0 kW tank Equipped as standard Optionally available
Other than above Not equipped
Controller cover Not equipped Optionally available
Noise filter Featured as standard
DCL (direct current reactor) Featured as standard Optionally available
Water fill/water leak test compliant tanks Available with non-standard types Optionally available
Accessories (level, temperature switch, thermometer, microseparator)
Available with non-standard types Optionally available
Com
patib
ility
Screw and wiring hole sizes of power/signal line terminal blocks
No change
Discharge / tank / drain port hole diameter No change
Power supply line / signal line wiring port positions
2.2 to 5.0kW No change Changed
Other than above No change
Discharge / tank / drain port hole diameter
3.7 to 5.0 kW - Return filter changed Discharge ports changed Changed
2.2, 2.8, 7.0 kW - Changed
11.0 kW No change