Evolution Daikin Chiller RangeNew Daikin Products 2007

Page 2: Evolution Daikin Chiller Range New Daikin Products 2007

2Apr 18, 2023

Daikin Chillers range

Page 3: Evolution Daikin Chiller Range New Daikin Products 2007

3Apr 18, 2023

R-4

10a

R-4

07c

R-1

34a

Mini-chiller: EWA/YQ005-007AC

Air-cooled range:

EUWA/Y5-24KA

EWAD650-C18BJ

EWAP800-C18AJEWAP110-540MB

EWA/YP060-260CA

EWAD120-600MB

EWAD190-600AJ

50 100 250 500 750 1000 1250 1500

Air-cooling capacity (kW)

Class/ kW 2000

1 circuit

2 circuits

3 circuits

4 circuits

Page 4: Evolution Daikin Chiller Range New Daikin Products 2007

4Apr 18, 2023

Water-cooled range:

R-4

07c

R-1

34a

EWWD120-540MB

EWWP014-065KA (Scroll)

EWWD170-600DJ

EWWD380-C11BJ

EWWD340-C19CJ

Flooded technology

50 100 250 500 750 1000 1250 1500

Water-cooling capacity (kW)

Class/ kW 2000

1 circuit

2 circuits

3 circuits

4 circuits

Page 5: Evolution Daikin Chiller Range New Daikin Products 2007

5Apr 18, 2023

Cooling range: 177 – 626 kW

Frame3100 & 3200 single screw compressor 2 efficiency versions: Std up to 2,77 and high up to 3,20 (EER)

2 refrigerant circuits truly independent

DX shell & tube evaporator – One pass refrigerant side

4 noise levels (ST-OPRN-OPLN-/Q-/A-/H) down to 62 dB(A)

R134a Ecologic Refrigerant

Frame3100

EWAD190-650AJYNN

Frame3200

Page 6: Evolution Daikin Chiller Range New Daikin Products 2007

6Apr 18, 2023

Cooling Range: 606 – 1920 kW

Frame4 Single-Screw Compressor

2 efficiency versions: Std up to 2,93 and High up to 3,32 (EER)

2 – 3 – 4 truly independent refrigerant circuits

DX shell & tube evaporator – One pass refrigerant side 4 noise levels (ST-OPRN-OPLN-Q/Z) down to 65dB(A) @ ISO 3744

R134a Ecologic Refrigerant

Frame4

EWAD650-C18BJYNN

Page 7: Evolution Daikin Chiller Range New Daikin Products 2007

7Apr 18, 2023

Cooling Range: 744 – 1729 kW

Frame4 Single-Screw Compressor

2 efficiency versions: Std up to 2,34 and High up to 2,69 (EER)

2 – 3 truly independent refrigerant circuits

DX shell & tube evaporator – One pass refrigerant side

3 noise levels (ST-OPRN-OPLN) down to 72,5dB(A) @ ISO 3744

R407C Ecologic Refrigerant

Frame4

EWAP800-C18AJYNN

Page 8: Evolution Daikin Chiller Range New Daikin Products 2007

8Apr 18, 2023

Frame3200

Cooling Range: 166 – 604 kW

Frame3200 Single-Screw Compressor

2 efficiency versions: Std up to 4 and High up to 4,7 (EER)

1 – 2 truly independent refrigerant circuits

DX shell & tube evaporator – One pass refrigerant side

Electronic Expansion device as standard

R134a Ecologic Refrigerant

EWWD170-600DJYNN

Page 9: Evolution Daikin Chiller Range New Daikin Products 2007

9Apr 18, 2023

Cooling Range: 334 – 1893 kW

Frame4 Single-Screw Compressor

EER range: 4,1 – 4,6

1 – 2 – 3 – 4 truly independent refrigerant circuits

DX shell & tube evaporator – One pass refrigerant side

Electronic Expansion device as standard

R134a Ecologic Refrigerant

Frame4

EWWD340-C19CJYNN

Page 10: Evolution Daikin Chiller Range New Daikin Products 2007

10Apr 18, 2023

Cooling Range: 369 – 1050 kW

Frame4 Single-Screw Compressor

EER up to 5,8

Very high EER values at part loads condition

Flooded Evaporator

Expansion valve with liquid level control

R134a Ecologic Refrigerant

Frame4

PART LOAD PERFORMANCE ARI std

0

1

2

3

4

5

6

7

8

9

10

0 10 20 30 40 50 60 70 80 90 100COOLING CAPACITY %

CO

P

VERY HIGH PART LOAD PERFORMANCE

EWWD380-C11BJYNN

Page 11: Evolution Daikin Chiller Range New Daikin Products 2007

Overview on NomenclatureNew Daikin Products 2007

Page 12: Evolution Daikin Chiller Range New Daikin Products 2007

12Apr 18, 2023

Daikin nomenclature (std unit)

EWA

ERA Air Cooled Condensing unit C/O

EWW Water-Cooled Chiller

EWL Remote Condenser Chiller

EWA Air-Cooled Chiller C/O

EWY Air-Cooled Chiller H/P

EWC Air-Cooled Chiller Centr. Fan

C/O = Cooling OnlyH/P = Heat PumpH/R = Heat Recovery

EWT Air Cooled Chiller C/O + H/R

Page 13: Evolution Daikin Chiller Range New Daikin Products 2007

13Apr 18, 2023

Daikin nomenclature (std unit)

D

D: R- 134aP: R- 407CQ: R- 410A

Kind of Refrigerant

EWA

Page 14: Evolution Daikin Chiller Range New Daikin Products 2007

14Apr 18, 2023

Daikin nomenclature (std unit)

360

Capacity Class kW(!) Cooling

From 1 to 950 kW

Above 950 kW:Use multiples of C(Roman Character for 100)

1000 kW = C10 (100x10)2500 kW = C25 (100x25)

DEWA

Page 15: Evolution Daikin Chiller Range New Daikin Products 2007

15Apr 18, 2023

Daikin nomenclature (std unit)

AJ

Model Series

First Character

Letter A,B,… Major Modification

Second Character

Letter A,B,… Minor Modification

360DEWA

Page 16: Evolution Daikin Chiller Range New Daikin Products 2007

16Apr 18, 2023

Daikin nomenclature (std unit)

YN

Power Supply

V1 : 1~ / 220-240V / 50Hz

V3 : 1~ / 230V / 50Hz

T1 : 3~ / 230V / 50Hz

W1 : 3N~ / 400V / 50Hz

Y1 : 3~ 380-415V / 50Hz

AJ360DEWA

YN : 3~ / 400V / 50Hz

Page 17: Evolution Daikin Chiller Range New Daikin Products 2007

17Apr 18, 2023

Daikin nomenclature (option mix)

N

Hydronic Module choicesHeat Recovery version

N : No Hydronic component (Std)

P : Pump + hydronics

B : P + Buffertank

A-V: Combinations of options like special or dual pumps and Heat recovery.

YNAJ360DEWA

Page 18: Evolution Daikin Chiller Range New Daikin Products 2007

18Apr 18, 2023

Daikin nomenclature (option mix)

****

Option Mix

**** : 4 digits

NYNAJ360DEWA1

Page 19: Evolution Daikin Chiller Range New Daikin Products 2007

19Apr 18, 2023

Daikin nomenclature (std unit)

****

Sound & Efficiency related options

/A

/Q

/Z

/H

Standard Efficiency (SE)

High Efficiency (HE)

SE + Extra low noise

HE + Extra low noise

High Ambient

/ANYNAJ360DEWA

Page 20: Evolution Daikin Chiller Range New Daikin Products 2007

20Apr 18, 2023

Noise & Efficiency• Std Noise, Std Efficiency Base Model

– OPRN: Reduced Noise, excludes compressor cabinet

– OPLN: Low Noise, includes compressor cabinet

• Std Noise, High Efficiency “/A” Base Model– OPRN: Reduced Noise, excludes compressor cabinet

– OPLN: Low Noise, includes compressor cabinet

• Extra Low Noise, Std Efficiency “/Q” Base Model

• Extra Low Noise, High Efficiency “/Z” Base Model

• High Ambient = “/H” Base Model

/AYNAJ360DEWA N

/A

/Q

/Z

/H

Page 21: Evolution Daikin Chiller Range New Daikin Products 2007

21Apr 18, 2023

Standard Daikin Options

EWAD AJYNN

EWAD BJYNN

EWAP AJYNN

EWWD DJYNN

EWWD CJYNN

EWWD BJYNN

Heatpump version (Waterside) Brine version Dual setpoint Thermal relays compressors Under / over voltage controller Victaulic on evaporator Victaulic on condenser Condenser coils Alucoat Flow switch for evaporator Setpoint reset and demand limit Alarm from external device Rubber type antivibration mounts

Aircooled Watercooled

Page 22: Evolution Daikin Chiller Range New Daikin Products 2007

22Apr 18, 2023

Standard Options Available

Option Description Option DescriptionOPSC Single contact OP03 Dual pressure relieve valveOPTC Twin contact OP10 Evaporator Heater tapeOPSP Single Pump OP12 Suction stop valveOPTP Twin pump or Dual pump OP52 Main switchOPHP High ESP pump OP57 A/V meterOPHT High ESP twin pump OPLN Low noiseOPBT Buffer Tank OPGA GaugesOPZH ZH OPCG Coil guardsOPZL ZL OPSS Soft starterOPNS No switchbox OPAC Address cardOPIF Inverter Fan OPEP Epoxy condenser finsOPHF High ESP fans OPAL Untreated aluminium condenser finsOPRN Reduced Noise OPPF Power Factor CorrectionOPFS Fan Silent OPSN Cu-Cu-Sn Condenser coilsOPLA Low ambient OPCU Cu-Cu Condenser coilsOPTR Total Heat Recovery OPNI Cu-Ni 90-10 S&T condenserOPPR Partial Heat Recovery or desuperheater OPEX Electronic Expansion Valve

Page 23: Evolution Daikin Chiller Range New Daikin Products 2007

23Apr 18, 2023