12
In Reply Refer To: GE 1035A July 17, 2017 Ms. Judy Archer Walter Oil & Gas Corporation UOO Louisiana, Suite 200 Houston, Texas 77002 Dear Ms. Archer: Reference is made to Walter Oil & Gas Corporation's right-of-way pipeline installation completion report for Pipeline Segment No. (PSN) 19315 associated with Right-of-way No. OCS-G29303, dated July 19, 2016 and received by this office on July 20, 2016. PSN 19315 is described as follows: PSN ROW Size Length Service Origin Termination 19315 G29303 10" 60,197 Oil Platform A Ewing Bank Area Block 834 12-inch SSTI Grand Isle Area Block 115 The total length ofthe "as-built" right-of-way is 11.4 miles. The report is submitted in accordance with 30 CFR 250.1008 (b). Right-of-way No. OCS-G29303 is described as follows: Pipeline Right-of-way (ROW) OCS-G29303 is a 200-fool wide and approximalely J 1.4 mile (60,197 feel) long corridor associaled wilh lhe 10 3/4-inch Pipeline Segment No. (PSN) 19315. The purpose of Pipeline ROW OCS-G29303 is to maintain and operate PSN 19315 and to transport oil from Platform A in Ewing Bank Area Block 834, through Ewing Bank Area Blocks 790, 746, 745, 701, through Grand Isle Block 120, to a 12-inch subsea lie-in wilh PSN 11433, at X= 2,596,570.62 and K= 10,285,217.33, in Grand Isle Area Block 115. The data provided in the report establishes the assigned maximum allowable operating pressure (MAOP) for the pipeline: PSN MAOP (psig) MAOP Determination 19315 1,800 Subsea Segment

In Reply Refer To: GE 1035A July 17, 2017 · The total length ofthe "as-built" right-of-way is 11.4 miles. The report is submitted in accordance with 30 CFR 250.1008 (b). Right-of-way

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: In Reply Refer To: GE 1035A July 17, 2017 · The total length ofthe "as-built" right-of-way is 11.4 miles. The report is submitted in accordance with 30 CFR 250.1008 (b). Right-of-way

In Reply Refer To: GE 1035A July 17, 2017

Ms. Judy Archer Walter Oil & Gas Corporation UOO Louisiana, Suite 200 Houston, Texas 77002

Dear Ms. Archer:

Reference is made to Walter Oil & Gas Corporation's right-of-way pipeline installation completion report for Pipeline Segment No. (PSN) 19315 associated with Right-of-way No. OCS-G29303, dated July 19, 2016 and received by this office on July 20, 2016.

PSN 19315 is described as follows:

PSN ROW Size Length Service Origin Termination

19315 G29303 10" 60,197 Oil Platform A

Ewing Bank Area Block 834

12-inch SSTI Grand Isle Area

Block 115

The total length ofthe "as-built" right-of-way is 11.4 miles.

The report is submitted in accordance with 30 CFR 250.1008 (b).

Right-of-way No. OCS-G29303 is described as follows:

Pipeline Right-of-way (ROW) OCS-G29303 is a 200-fool wide and approximalely J 1.4 mile (60,197 feel) long corridor associaled wilh lhe 10 3/4-inch Pipeline Segment No. (PSN) 19315. The purpose of Pipeline ROW OCS-G29303 is to maintain and operate PSN 19315 and to transport oil from Platform A in Ewing Bank Area Block 834, through Ewing Bank Area Blocks 790, 746, 745, 701, through Grand Isle Block 120, to a 12-inch subsea lie-in wilh PSN 11433, at X= 2,596,570.62 and K= 10,285,217.33, in Grand Isle Area Block 115.

The data provided in the report establishes the assigned maximum allowable operating pressure (MAOP) for the pipeline:

PSN MAOP (psig) MAOP Determination 19315 1,800 Subsea Segment

Page 2: In Reply Refer To: GE 1035A July 17, 2017 · The total length ofthe "as-built" right-of-way is 11.4 miles. The report is submitted in accordance with 30 CFR 250.1008 (b). Right-of-way

Page 2

The high and low-pressure sensors shall be set no higher than 15 percent above and below the normal operating range, respectively. The high pilot, however, shall not be set higher than the MAOP ofthe pipeline. The pressure range shall be established by thc use of pressure recorders.

Sincerely,

(org. sgd.) J. Caraher

(for) Bryan A. Domangue Acting Regional Supervisor Regional Field Operations

bc: 1502-01 Segment No. 19315 with Completion Report (GE 1035A) 1502-01 ROW OCS-G G29303 (Scanning) (GE 274A) JCaraher: Segment No. 19315

Page 3: In Reply Refer To: GE 1035A July 17, 2017 · The total length ofthe "as-built" right-of-way is 11.4 miles. The report is submitted in accordance with 30 CFR 250.1008 (b). Right-of-way

f f WALTER OIL & GAS CORPORATION

July 19, 2016

Commander (dpw) Eighth Coast Guard District Hale Boggs Federal Building 500 Poydras Street, Room 1230 NewOrleans, Louisiana 70130

Re: 10.750-Inch O.D. Oil Right-of-Way Pipeline Installed In and/or Through Blocks 834, 790, 745, 701, Ewing Bank Area and Blocks 120 and 115, Grand Isle Area Offshore, Louisiana, OCS Federal Waters, GOM Pipeline Segment No. 19315; ROW No. OCS-G 29303 Permit No.: MVN-2015-0269-CQ

Gentlemen:

In accordance with the pipeline approved permit from the Corps of Engineers dated July 6, 2015, please be advised that the subject pipeline was installed in and through the above referenced blocks on June 4, 2016. Also in accordance with said pipeline approval, enclosed please find an "as-built" pipeline plat.

Should you have any questions or need additional information, please contact the undersigned by telephone at (713) 659-1222 or via email [email protected].

Very truly yours, WALTER OIL & GAS CORPORATION

Judy Archer Regulatory/Environmental Coordinator

Enclosure

1100 Louisiana, Suite 200 • Houston, Texas 77002-5299 • 713-659-1221

Page 4: In Reply Refer To: GE 1035A July 17, 2017 · The total length ofthe "as-built" right-of-way is 11.4 miles. The report is submitted in accordance with 30 CFR 250.1008 (b). Right-of-way

LEGEND:

O 5

AS-UUD PIPELINE

A o o m c m . PROJECT P m i N E

EXISTMG PIPOtC/UUeuCAL AS PER BSEE

CMBLAP WTTH AOJOMNG CHART

TE POINT (EVERY STH LABELLED)

NOTES:

t . EXISTING DATABASE INFORMATION SHOWN HEREON HAS BEEN PROVBE BT OTHER. SUBSEA7 MAKES NO CLAMS TO THE ACCURACY OR COMPLETENESS OF SAID DATA

2. THIS AS-LAID SURVEY WAS PERFORMED UTILIZING ACCEPTABLE OFFSHORE PROCEDURES AND ACCURACIES, PRECISIONS SHOWN HEREON ARE FOR COMPUTATIONAL PURPOSE ONLY AND NOT INTENDED TO INDICATE ACTUAL PRECISION OF SURVEY.

3. WGS84 TO NAD 27 CONVERSION USING NGS NADCON CONUS DATUM SHIFT FORMULA.

4. SURFACE POSmON: VERIPOS APEX-LD2 DGNSS.

5 SUBSEA POSITION, SIMRAD HiPAP 500 USBL / IX BLUE RAMSES SPARSE LBL

6. AS-LAID SURVEY DATE: JANUARY 2016 (PLSV SEVEN OCEANS)

7. JUMPER SURVEY PERFORMED BY OCEANEERING ON APRIL 26 -27 , 2016 ABOARD THE MSV OCEAN INTERVENTION.

B. TC-IN SPOOL INSTALLED BY DEEPCOR ON JUNE 8, 2016 (DSV MIDNIGHT STAR).

T l i NORTHING ( T ) E A S n N C ( X ) REMARKS n t N O R T H I N G | V ) t A S T I N G (X) KEHAKKS

10.231,491 81 2.623,470 X7 BOTTOM Ot RISER Hue 3S 10,246.243 S9 2.615,979 89

2 10,231,496 20 2,623,378 29 10" OIL P^ET HUB 36 10.246.692.24 2,615.759 20

3 10,231,944 65 2.623,153.45 37 10,247.142.52 2,615,541 86

« 10.232.390 23 2.622,926 63 38 10.247.586 79 2,615.312.51

5 10,232,640 00 2,622,803.00 BLOCKUNE CROSSING CVV834 lo EW790 39 10,248,033 13 2.615,088 60

£ 10.233,2«O 22 2.622,470.88 40 10.248.480 X 2.614.856 74 BLOCKUNE CROSSING EW790 to EW746

10,233,729.46 2.622,251.39 41 10.248.922.16 2.614,629 43

8 10.234,173.61 2.622.02I.8S 42 10.249.371.29 2.614.409.72

• 10.234.621 92 2,621,800 65 43 10,249.819 62 2,614,188 36

10 10.235.068 93 2.621,576.93 - 10,250.269 49 2.613.970 16

11 10.235.521.71 2.621,364.97 45 10.2S0.722.ai 2.613.757.65

12 10,235,965.15 2,621,13398 46 10,251.029 77 2,613,600 00 BLOCKUNE CROSSING EW746 to EW745

13 10,236,412 38 2,620,910.54 47 10,251,613 16 2,613,304 32

14 10,236,860 17 2,620,688 19 48 10.252.063.13 2,613,085 93

15 10,237,306 95 2,620,463.88 49 10.2S2.5O6 65 2,612,855 11

16 10.237,747.99 2.620,228.36 so 10.252.957 02 2.612.637 95

10,238,194.69 2,620,004 08 51 10,253,400 45 2.612.407 09

IB 10,238,643.79 2,619,784.55 S2 10.253,849 31 2.612,186.96

19 10,239,090 94 2.619.561 36 S3 10.2S4.295.00 2.611,960.40

20 10.239,536 11 2,619.333 72 54 10.254.743 47 2.611,739 39

10 .239 ,9«1 .23 2.619,105.99 55 10.255.185 98 2,611,S06 63

22 10.240,431 22 2,618.888 03 M 10.255.630 80 2.611.278.31

23 10,240,881.10 2,618,669 85 57 10,256,077.43 2.611.053.97

24 10,241,328.01 2,618,445.70 58 10,256.525 48 2,610,831 63

25 10,241,771.36 2.618.214.53 M 10.256,972 94 2,610,608 52

26 10.242,216.7] 2.617,987 26 60 10,257,420 47 2,610.385 55

10,242,666 00 2.617,767 86 61 10,257.869 «S 2,610,165 92

28 10,243,112.45 2,617.542.75 62 10.258,316.77 2,609,942 13

29 10.243.563.04 2,617.326 06 63 10.258,765 03 2,609,720.58

X 10,244.010 45 2.617.102.87 10,259.210 13 2.609.492 92

31 10,244.454 33 2,616.872.75 65 10.259,659 31 2,609,273.29

32 10,2*4,899 34 2.616.644 85 66 10.260,109 60 2,609.055 96

33 10,245,352 47 2.616,433.53 67 10,260,555 81 2,608.830 48

3* 10,245,797.06 2.616.204.76 88 10,261,002 63 2,608,606.11

SiJftvfr (mFMt

I HEREBY CERTIFY THAT THE HORIZONTAL POSITION OF THE AS-BUILT SHOWN HEREON. IS BASED UPON GENERALLY ACCEPTED INDUSTRY METHOS AND STANDARDS. UTIUZING POSITION SYSTEMS AS NOTED.

DATE: 7//fM

2500

HORIZONTAL SCALE 1 * : 2 .500 ' 0 2500 5000 7500

i J US Survey F M t

UNIVERSAL TRANS EVERSE MERCATOR PROJECTION UTM ZONE 15(N), CENTRAL MERIDIAN 93* W

CLARKE 1866 SPHEROID. NORTH AMERICAN DATUM 1927 U.S. SURVEY FEET

^ WALTER OIL & GAS COfePORATION

DRAWING Wil:

CONTRACTOR:

s u b s e s 7 WALTER OIL 8c GAS COELACANTH

10.75"EXPORT OIL PIPELINE BLOCKS EW834 TO GUI5

SEGMENT N' 19315

Rev

7/15/2016

7/14/2016

7/13/2016

Date TSCALT

ANSI B

Approved for Construction

Issued for Client Approval

Issued for Internal Review

Reason for Issue Sf tmC No.:

T C 1 0 7 6 - D R - 0 1 - 8 3 0 1 2

J.N

J.N

J.N

Drawn

Chort

F.G

F.O

F.G

Check

Of

S.K

S.K

App'd

Page 5: In Reply Refer To: GE 1035A July 17, 2017 · The total length ofthe "as-built" right-of-way is 11.4 miles. The report is submitted in accordance with 30 CFR 250.1008 (b). Right-of-way

Gl 115

GRAND ISLE AREA

LEGEND:

AS-LAID PIPQJNE

— _ — n x x n i m . PROJECT P*>E1JNE

EXISTINC PIPEUt/UNBUCAL AS PER BSEE

o 5

- OVERLAP WITH AOJOMNG CHART

T l POKT (EVERY STH LABELLED)

NOTES:

1. EXISTING DATABASE INFORMATION SHOWN HEREON HAS BEEN PROVIDE BY OTHER. SUBSEA7 MAKES NO CLAWS TO THE ACCURACY OR COMPLETENESS OF SAO DATA 2. THIS AS-LAID SURVEY WAS PERFORMED UTIUZING ACCEPTABLE OFFSHORE PROCEDURES AND ACCURACIES PRECISIONS SHOWN HEREON ARE FOR COM PUT ATONAL PURPOSE ONLY AND NOT WTENDED TO INDICATE ACTUAL PRECISION OF SURVEY. 3. WGS84 TO NAD 27 CONVERSION USING NCS NADCON CONUS DATUM SHIR FORMULA 4. SURFACE POSITION: VERIPOS APEX-LD2 DGNSS. 5 SUBSEA POSITION: SIMRAD HIPAP 500 USBL / IX BLUE RAMSES SPARSE LBL 6. AS-LAID SURVEY DATE: JANUARY 2016 (PLSV SEVEN OCEANS) 7. JUMPER SURVEY PERFORMED BY OCEANEERING ON APRIL 26-27. 2016 ABOARD THE MSV OCEAN INTERVENTION. 8. TIE-IN SPOOL INSTALLED BY DEEPCOR ON JUNE 8. 2016 (DSV MIDNIGHT STAR).

TIE NORTHING (Y) (ASTING ( « | REMARKS TII NORTHING (T ) t A S T I N C ( X )

69 10.261,449 53 2.608.381 87 99 10,274,863 30 2,601.670 S7

70 10,261,895 33 2.608.155 47 100 10,275.312 09 2.601,450 28

71 10.262.34C 99 2.607.928 81 101 10.27S.7S4 98 2.601.218.25

72 10.262,786 32 2.407.701 49 102 10.276.202.23 2.600.994 72

10.263,236.05 2.607.483 OC 103 10,276,649 91 2,600.772.08

« 10,263.683 5C 2.607.259 90 104 10.277.096 73 2.600,547 72

10.264.320.OC 2.606.948.77 BLOCKJNt CROSSING ew745 to EW701 105 10.277.S43.82 2.600,323 88

76 10,264.579.11 2,606.815 36 106 10.277,991 42 2,600,101 14

77 10.265.027.23 2.606.593 60 107 10.278,438 39 2,599.877.13

78 10,265,474 81 2.606.370 72 108 10,278.886 6 ' 2,599,655.76

79 10.265.922 78 2.606,148 64 109 10,279,332.11 2,599,428 68

80 10.266.371.83 2.605.928 75 110 10,279.779 42 2,599,205 38

81 10,266,81841 2,605,703 90 111 10,279.893 77 2,599,149.78 WALTER 0»G I " UMB SEG» 14154

82 10,267,264 43 2,605,477 91 112 10,280.093.13 2,599.051.14 WALTtR OftG S£G» 17309. 17310

83 10.267,707 48 2,605.246.19 113 10,280.228 42 2,598.985 80 WALTER 08iG SCG4 17311. 17312, 17313

64 10.268,155.84 2.605,024.94 114 10.280,290 18 2.598.954 74 WALTER O&G 2" UBEH, S£G» 17411

85 10.268.589.55 2,604.809 45 BcOCKUNC CROSSING ew701 to Gr.20 115 10,280,319 54 2.594.941 42 WALTER O&G 4 - BLKO. SEG* 18613

86 10.269.050.73 2.604.576 64 116 10.280.228 56 2.598.985 70

87 10.269.496.83 2.604.352 85 117 10,280.677 55 2.598,765 75

88 10,269.945.52 2.604.132.21 118 10.281.628 BG 2,598,285.85 W I L U A M S ENERG- 8 GAS SEG* : 1457

89 10.270.392 76 2.603.908 85 119 10.281.759 10 2.598.216.71 E N I P T H I O U U M u s 12- O I L seG» 11458

90 10.270.839.09 2.603.683 50 120 10,282.016.38 2.598.089 49

91 10,271,286 87 2,603,461 08 m 10.282.462 40 2.597.863 51

92 10,271.734.70 2 . t 03 .238 . t l 122 10.282.909 97 2.597.640 70

93 10.272.183.01 2.603.017 SO 123 10,283.357.56 2,S«7,417.88

9 * 10.272.630 06 2.602.793.64 124 10.283.805 66 2,597,196 06

95 10.273.077 96 2.602.571 49 125 10.284,251 84 2.596.970 50

96 10.273.525.23 2.602.344 10 BLOCKLINE CROSSING CI120 to Q 1 1 5 126 10.284.529 08 2,596,830 14 DISCOVERY GAS TRANS 20" GAS SEG» 11175

97 10.273.971.72 2,602,123 00 127 10,285,180 25 2.596.514 47 PIPELINE 'LANGI

98 10.274.418.17 2,601,898 06 128 10.285.217 33 2.596,570 62 MOT TAP FLANGE

SURVEY mmm

I HEREBY CERTIFY THAT THE HORIZONTAL POSITION OF THE AS-BUILT SHOWN HEREON. IS BASED

UPON GENERALLY ACCEPTED IN^L/STRY METHOS AND STANDARDS. UTIUZING POSITION SYSTEMS AS

NOTED. J I

HEIDRitH P.LS REG. #4826 DATE:

ll//..

2500 HORIZONTAL SCALE I "

2500

2.500 ' DARHEL HI IURICH TSO^tG No 4826

J REGISTE ^ED •PROFESS QNAl

US Survey FMt

UNIVERSAL TRANS EVERSE MERCATOR PROJECTION UTM ZONE 15(N). CENTRAL MERIDIAN 97 W

CLARKE 1866 SPHEROID. NORTH AMERICAN DATUM 1927 U.S. SURVEY FEET

' " " / N i m i

CUENT;

^ WALTER OIL & GAS CORPORATION

DRAWING TITLE:

CONTRACTOR:

s u b s e s 7 WALTER OIL Sc GAS COELACANTH

10.75"EXP0RT OIL PIPELINE BLOCKS EW834 TO Oil 15

SEGMENT N* 19315

Rev

7/15/2016

7/14/2016

7/13/2016

Dote

ANSI B

Approved for Construction

Issued for Client Approvol

Issued for Intemol Review

5SEF r:2.500'

Reason for Issue

R bwd No.: T C 1 0 7 6 - D R - 0 2 - 8 3 0 1 2

J.N

J.N

J.N

Drawn

Chort

F.G

F.G

r.G

Check

S.K

S.K

App'd

UEv!

V i

Page 6: In Reply Refer To: GE 1035A July 17, 2017 · The total length ofthe "as-built" right-of-way is 11.4 miles. The report is submitted in accordance with 30 CFR 250.1008 (b). Right-of-way

Greene's Energy Group

DEADWEIGHT LOG REPORT

DOCUMENT COM-OPE-FRM-05

PAGE 1 OF 1

VERSION 70

PURPOSE This form is used by Greene s Energy Group at all its locations, divisions, and subsidiaries to record deadweight tesl data

PROCEDURE Complete form as indicated and file according to the requirements ol SQP-4.2 4

CUSTOMER AFE/POI, / - j ^ ) DATE

ADDRESS GEG Job » ^ ^ O | T £ >

CITY/STATEZIP iAc u-^ cw1 ^ y '1 ^ £O 1^

LEASE r>c -sc- z n ^ / ^ z , . FIELD

TEST NUMBER DATE & TIME STARTED ^ j T / f • COMPLETED C; " V ' / ^ ' J

SERIAL NUMBERS OF INSTRUMENTS USED ON TEST

DEADWEIGHT SER « ^ / C * ^ ^ - ? , C A L DATE 5 - 7 _ 5 ~ t < g PRESS RECORDER SER » ̂ y ^ / ^ ti '^i Z 4, CAL DATE ^-2'\-IL-

AMBIENT TEMP SER a ^ V Z / U ' c ^ A L DATE - 5 - 2 S ' ( INT TEMP SER • CAL CATE

EXT TEMP SER » 2 ^ / ^ ^ 5 Z ^ L - CAL DATE 2*)-Li, GRND TEMPSER « CAL DATE

WATER TEMP SER » CAL DATE TEST GAUGE »

Additional Inslr SER « CAL DATE Addiiional Instr SER « CAL DATE

DATA ON PIPE SEGMENT(S) IN TEST SECTION:

LINE OWNER / ^ ^ CONTRACTOR

LOCATION £^ Cv " ^ ^ ( - { Vt5FFSHORE : LAND

L.'.E CESCP " ^ l ' ' . NAMI

ZL DIAMETER / C 1 ^ SCHEDA r^/ S L- GRADE K M " Z . LENGTH / / . e V / H -

D A'.'ETE^ SCHED GRADE LENGTH

DIAMETER WALL GRADE LENGTH

GEO TEST PUMP » '.^ Q _ 3 J g TEST MEDIUM , _L MAXIMUM TEST PRESSURE 1 _ 3 O

MAXIMUM RECORDED PRESSURE "2. 3 3 3

MINIMUM TEST PRESSURE 2 - Z - O

MINIMUM RECORDED PRESSURE 2 ^ 1 3

INSTRUMENT READINGS

TIME DWT TG TW COMMENTS

n : 0 9 ^4 •? g 3 S.

43. - L t -

3. 3

I ' M ?

4 ^ ±

3 T

LS53

TEST RESULTS U^CCEPTABLE JNACCEPTABI E TEST DURATION ^ HRS

WEATHER CONDITIONS ^ C l"^. >yv ^ . I

'ACCEPTANCE OF TEST*

The s ign ing of th is document be low acknowledges the acceptance of the test by the Client accord ing to the readings on th is f o rm and approves the bleed down of test pressure The pressure was bled down tn Q PSIG by GEG.

SIGNATURES (required):

CLIENT REPRESENTATIVE SIGNATURE

PRINT:

4 ^ COMPANY PHONE «

hmcian ) GEG T»«hnician) CHECK ONE OF THE FOLLOWING 1 ^ - — " CLIENT TO KEEP ORIGINAL CHARTS AND DEADWEIGHT LOG

GEG TO COMPLETE TYPED TEST BOOKLET ANO MAIL TO ADDRESS ABOVE GEG TO COMPLETE CERTIFIED TEST PACKAGE WITH ENGINEER'S STAMP AND MAIL T O A D D R E S S A B O V E ( I I S I MUST BE ACCEPTED BT GEG ENGINEER PRIOR TO DEPRESSURIZlNGl

REFERENCE SQP-4 2 4 Control of Records

DISTRIBUTION None

Page 7: In Reply Refer To: GE 1035A July 17, 2017 · The total length ofthe "as-built" right-of-way is 11.4 miles. The report is submitted in accordance with 30 CFR 250.1008 (b). Right-of-way

DOWN HOLE

PRESSURE, INC. I N S T R U M E N T R E N T A L S & R E P A I R S

Phono Fax

(337)837*2756 (337) 037-275G

I' O. Uox 497 400 S. Eola Rd. Broussard. LA. 70510

Surface Gauges Dead Weight Testers

Barton Recorders Vaetrix Gauge 1

5,10,8120,000 PSI

Sub Surface Gauges Electronic & Mechanical

0-25,000 PSI Ranges Temperature Gauges

0-450 Degrees F.

CALIBRATION CERTIFICATE DESCRIPTION VAETRIX GAUGE 2 SERIAL NUMBER 51606-2

PRESSURE RANGE 5000 ACCURACY*/- 0 1 % FULL SERVICE +/- 5 P.S.I.

PRESSURE (PSI) ARRIVING ON CALIBRATION TABLE

APPLIED PRESSURE INDICATED PRESSURE DIFFERENCE

0 0 0 1.000 1.004 4 2.000 2.004 4 3.000 3.004 4 4,000 4.002 2 5,000 4,999 -1

PRESSURE (PSI) DEPARTING CALIBRATION TABLE

APPLIED PRESSURE INDICATED PRESSURE DIFFERENCE

0 0 0 1,000 1,004 4 2,000 2,004 4 3,000 3,004 4 4.000 4.002 2 5,000 4.999 -1

INSTRUMENT CALIBRATED IN THE VERTICAL POSITION ROOM TEMP 74 F

This instrument upon receiving on calibration table was found to be within manufacters tolerance. This Instrument upon receiving on calibration table was found to be out of manufacters tolerance.

This is to certify that this instrument has been inspected and tested against Pressure Standard Chandler Engineering Dead Weight Tester Model # 58-200H. Serial # 16210 traceable to the National Institute of Standards and Technology, (NIST) Reference # R68113032501 . Calibrated (04/14/2016). Reference Standard Serial # 211H14150045.. Certified Pressure Transducer ( 36000 PSI ,01%). The calibration systems conforms to all ISO 9001:2008 and API Spec. 01 requirements. Also let it be known that all calibrations

are performed by qualified DHP personnel using instrumentation and methods which guarantee precise accuracy.

xxxxxx

DATE OF CALIBRATION CALIBRATION DUE DATE

05/23/16 TECHNICIAN 11/23/16

Page 8: In Reply Refer To: GE 1035A July 17, 2017 · The total length ofthe "as-built" right-of-way is 11.4 miles. The report is submitted in accordance with 30 CFR 250.1008 (b). Right-of-way

DOWN HOLE

PRESSURE, INC. I N S T R U M E N T R E N T A L S & R E P A I R S

Phone Fax

(337) 837-2755 (337) 837-2756

P.O. Box 497 408 S. Eola Rd. Broussard, LA. 70518

Surface Gauges Dead Weight Testers

Barton Recorders Vaetrix Gauge 1

5,10, & 20,000 PSI

Sub Surface Gauges Electronic & Mechanical

0-25,000 PSI Ranges Temperature Gauges

0-450 Degrees F.

DESCRIPTION CALIBRATION CERTIFICATE

BARTON TEMPERATURE RECORDER SERIAL NUMBER 242A-()f!2306

TEMPERATURE RANGE 150 ACCURACY+/- 1% FULL SERVICE +/- 1.5 DEGREES

TEMPERATURE (F) ARRIVING ON CALIBRATION TABLE

APPLIED TEMP INDICATED TEMP DIFFERENCE

32 32 0 60 60 0 90 90 0 120 120 0 144 144 0

TEMPERATURE (F) DEPARTING CALIBRATION TABLE

APPLIED TEMP INDICATED TEMP DIFFERENCE

32 32 0 60 60 0 90 90 0 120 120 0 137 137 0

INSTRUMENT CALIBRATED IN THE VERTICAL POSITION ROOM TEMP 73 F

This instrument upon receiving on calibration table was found to be within manufacters tolerance. This instrument upon receiving on calibration table was found to be out of manufacters tolerance.

This is to certify that this instrument has been inspected and tested against Digital Thermometer No.031913003. Calibrated (08/06/15). Using certified Yellow-Back Thermometer 35854-003 s/n 9004. Traceable to the National Institute of Standards & Technology (NIST) Reference # 94417'88024,82564,1428301 and 1470271. This calibration meets or exceeds all ANSI-NCSL-1 STD.,MIL.STD.45662A calibration procedures Also let it be known that all calibrations are perfomed by qualified Down Hole Pressure personel using instrumentation and methods which guarantee precise accuracy.

xxxxx

DATE OF CALIBRATION CALIBRATION DUE DATE

05/25/16 TECHNICIAN 11/25/16

^ E ^ f ^ ^ Q I E

Page 9: In Reply Refer To: GE 1035A July 17, 2017 · The total length ofthe "as-built" right-of-way is 11.4 miles. The report is submitted in accordance with 30 CFR 250.1008 (b). Right-of-way

DOWN HOLE

PRESSURE, INC. I N S T R U M E N T R E N T A L S & R E P A I R S

Phone Fax

(337) 837-2755 (337) 837-2756

P.O. Box 497 ^08 S. Eola Rd. Broussard, LA. 70518

Surface Gauges Dead Weight Testers

Barton Recorders Vaetrix Gauge 1

5 ,10 ,4 20,000 PSI

Sub Surface Gauges Electronic & Mechanical

0-25,000 PSI Ranges Temperature Gauges

0-450 Degrees F.

CALIBRATION CERTIFICATE DESCRIPTION BARTON PRESSURE METFR

PRESSURE RANGE 5000 ACCURACY*/-

SERIAL NUMBER

1 % FULL SERVICE •/-

242A-052306

50 P.S.I.

PRESSURE (PSI) ARRIVING ON CALIBRATION TABLE

APPLIED PRESSURE INDICATED PRESSURE DIFFERENCE

0 0 0 1,000 998 -2 2,000 1,996 -4 3,000 2,994 -6 4,000 3,992 -8 5,000 4,990 -10

PRESSURE (PSI) DEPARTING CALIBRATION TABLE

APPLIED PRESSURE INDICATED PRESSURE DIFFERENCE

0 0 0 1.000 1.000 0 2,000 2.000 0 3,000 3,000 0 4,000 4.000 0 5,000 5,000 0

INSTRUMENT CALIBRATED IN THE VERTICAL POSITION ROOM TEMP 73 F

This instrument upon receiving on calibration table was found to be within manufacters tolerance. This instrument upon receiving on calibration table was found to be out of manufacters tolerance.

This is to certify that this instrument has been inspected and tested against Pressure Standard Chandler Engineering Dead Weight Tester Model # 58-200H, Serial # 16210 traceable to the National Institute of Standards and Technology, (NIST) Reference # R68113032501 , Calibrated (04/14/2016). Reference Standard Serial # 211H14150045.. Certified Pressure Transducer ( 36000 PSI .01%). The calibration systems conforms to all ISO 9001:2008 and API Spec. Q l requirements. Also let it be known that all calibrations are performed by qualified DHP personnel using instrumentation and methods which guarantee precise accuracy

xxxxxxx

DATE OF CALIBRATION CALIBRATION DUE DATE

05/25/16 11/25/16

TECHNICIAN ^REGG|g S/^QIE

Page 10: In Reply Refer To: GE 1035A July 17, 2017 · The total length ofthe "as-built" right-of-way is 11.4 miles. The report is submitted in accordance with 30 CFR 250.1008 (b). Right-of-way

Surface Gauges Dead Weight Testers

Barton Recorders Vaetrix Gauge 1

5,10, & 20,000 PSI

DOWN HOLE

PRESSURE. INC. I N S T R U M E N T R E N T A L S & R E P A I R S

a y j

Phone Fax

(337) 837-2755 (337) 837-2756

P.O Box 497 408 S, Eola Rd. Broussard. LA. 70518

Sub Surface Gauges Electronic & Mechanical

0-25,000 PSI Ranges Temperature Gauges

0-450 Degrees F.

CALIBRATION CERTIFICATE DESCRIPTION TEMPERATURE RECORDER

TEMP. RANGE OTO 150 ACCURACY+/-

SERIAL NUMBER 242A-021506R

1 % FULL SERVICE+/- 1.5 F P.S.I.

TEMPERATURE RECEIVING ON CALIBRATION TABLE

TEMPERATURE TEMPERATURE DIFFERENCE

32 32 0 60 60 0 90 90 0 120 120 0 139 139 0

TEMPERATURE LEAVING CALIBRATION TABLE

TEMPERATURE TEMPERATURE DIFFERENCE

32 32 0 60 60 0 90 90 0 120 120 0 137 137 0

Cal ibrated in VERTICAL Position Instrument Room Temp. 73

This instrument upon receiving on calibration table was found to be within manufacters tolerance. This instrument upon receiving on calibration table was found to be out of manufacters tolerance.

This is to certify that this instrument has been inspected and tested against Digital Thermometer No.031913003. Calibrated (08/06/15). Using certified Yellow-Back Thermometer 35854-003 s/n 9004. Traceable to the National Institute of Standards & Technology (NIST) Reference # 94417,88024182564.1428301 and 1470271. This calibration meets or exceeds all ANSI-NCSL-1 STD..MIL.STD.45662A calibration procedures Also let it be known that all calibrations are perfomed by qualified Down Hole Pressure personel using instrumentation and methods which guarantee precise accuracy.

F.

xxxxxxxx

DATE OF CALIBRATION CALIBRATION DUE DATE

05/25/16 TECHNICIAN 11/25/16

Page 11: In Reply Refer To: GE 1035A July 17, 2017 · The total length ofthe "as-built" right-of-way is 11.4 miles. The report is submitted in accordance with 30 CFR 250.1008 (b). Right-of-way

6 AM

Z o o z

Page 12: In Reply Refer To: GE 1035A July 17, 2017 · The total length ofthe "as-built" right-of-way is 11.4 miles. The report is submitted in accordance with 30 CFR 250.1008 (b). Right-of-way