product catalogue
the a-z of insulation
ims p
rod
uct
cata
log
ue
the a
-zo
f insu
lation
product catalogue
Russell Road, Southport, Merseyside PR9 7SB. U.K.t: +44 (0) 1704 226878 f: +44 (0) 1704 225857 email: [email protected] web: www.ims-insulation.com
IMS LinatcoPO Box 30450Richards Bay3900 South AfricaPh/Fax: +27357535200
IMS Head OfficeRussell Road Southport Merseyside PR9 7SB UK Ph: +44 1704 226878 Fax: +44 1704 225857
IMSPark Road Industrial Estate Newport Gwent NP1 6PU UK Ph: +44 1633 601377 Fx: +44 1633 613595
IMS Wrights RefractoriesBridge Works Bridge Street Wordsley Stourbridge West Midlands DY8 5YU UK Ph: +44 01384 76493 Fx: +44 01384 30131
IMSDock Road South Bromborough Wirrall CH62 4SP UK Ph: +44 151 6459000 Fax: +44 151 6456987
IMS Hungary2191 BagJkai u. 44/aHungaryPh/Fax: +36-28-504-086Mobile: +36-30-952-2794e-mail:[email protected]
IMS Asia PacificUnit 12/13Berry StreetClydeNSW 2142Ph: +61 298 330020Ph: +61 412 002718
IMS EspanaPADUA 96 3 A08006 BarcelonaSpainPh/Fax: +34 93 417 2370
IMS Dubai Llc203 Al Hawai TowerSheikh Zayed RoadDubaiUAEPh: +9714 3211104Fax: +9714 3211644email: [email protected]
IMS PolskaOs Kombatantw 10/1331-630 KrakwPolandPh/Fax: +48 12 647 4468
IMS Bahrain109 Building 1207Road 3928East Rifa 939 KINGDOM OF BAHRAIN
107
con
version
table
the a-z of insulation
the
a-z o
f insu
latio
n
Sales Line +44 (0) 1704 226 878
LINEARinches ......................millimetres................25.4millimetres ..............inches ......................0.0394inches ......................centimetres ..............2.54centimetres..............inches ......................0.3937feet..........................metres ......................0.3048metres ....................feet ..........................3.281
SQUAREsq inches..................sq centimetres ..........6.452sq centimetres ........sq inches ..................0.155sq metres ................sq feet ......................10.76sq feet ....................sq metres..................0.0929
CUBICcubic inches ............cubic centimetres......16.39cubic centimetres ....cubic inches..............0.06102cubic feet ................cubic metres ............0.02832cubic metres ............cubic feet ................35.315
CAPACITYlitres ........................cubic feet ................0.03531litres ........................UK gallons ................0.22litres ........................US gallons ................0.2642litres ........................pints ........................1.76centilitres ................fluid ounce ..............0.35cubic feet ................litres ........................28.32UK gallons ..............litres ........................4.546US gallons................litres ........................3.785pints ........................litres ........................0.5682fluid ounce ............centilitres ................2.857
WEIGHTmetric tons ............gross tons ................0.9842metric tons ............short tons ................1.102kilograms ................hundred weights ......0.01968kilograms ................pounds ....................2.205grams ......................ounces......................0.03527gross tons ................metric tons ..............1.0161short tons ................metric tons ..............0.9074hundred weights......kilograms..................50.813pounds ....................kilograms..................0.45359ounces ....................grams ......................28.329
DENSITYkg/m3 ......................lbs./cu.ft. ..................0.06242lbs./cu.ft ..................kg/m3 ......................16.02
PRESSUREkp/cm3 ....................lbs./sq.in. ..................14.223kp/cm3 ....................MPa. ........................0.0981MPa ........................lbs./sq.in ..................145.0lbs./sq.in ..................kp/cm3 ....................0.07031MPa ........................kp/cm3 ....................10.194lbs./sq.in ..................MPa.......................... 0.0069
VELOCITYmetres/second ........feet/second ..............3.279feet/second..............metres/second ........0.305
ENERGYkilocalories ..............kiloJoules..................4.184kilocalories ..............British thermal units..3.9683kiloJoules ................British thermal units..0.9484watts ......................BTU/h ......................3.4128kcal/h ......................BTU/h ......................3.9683kiloJoules ................kilocalories................0.2389British thermal units kilocalories................0.2520British thermal units kiloJoules..................1.0544BTU/h ......................watts ........................0.2930BTU/h ......................kcal/h ......................0.2520
HEATkcal/m3 ....................BTU/cubic feet ..........0.11236kJ/m3 ......................BTU/cubic feet ..........0.0268kcal/m3 ....................kJ/m3........................4.184kcal/h ......................BTU/h ......................3.968kcal/h ......................Wh/h ........................1.1622Wh/h ......................BTU/h ......................3.4128kcal/(kg C) ..............BTU/(lb F) ................1.0kcal/(kg C) ..............kJ/(kg K) ..................4.184kJ/(kg K) ..................BTU/(lb F)..................0.2389kcal/(m2 h) ..............BTU/(sq.ft h) ............0.3686kcal/(m2 h) ..............Wh/(m2h) ................1.1622Wh/(m2 h) ................BTU/(sq.ft h) ............0.3171kcal/(m h C) ............BTU/(sq.ft h F/in) ......8.0645kcal/(m h C) ............W/(m K)....................1.1628W/(m K) ..................BTU/(sq.ft h F/in) ......6.9347W/(m K) ..................BTU/(ft h F) ..............0.5779W/(m2 K) ................BTU/(sq.ft h F) ..........0.1761
BTU/cubic feet ........kcal/m3 ....................8.90BTU/cubic feet ........kJ/m3 ......................37.313kJ/m3 ......................kcal/m3 ....................0.2390BTU/h ......................kcal/h ......................0.252Wh/h ......................kcal/h ......................0.8604BTU/h ......................Wh/h ........................0.2930BTU/(lb F) ................kcal/(kg C) ..............1.0kJ/(kg K) ..................kcal/(kg C) ..............0.239BTU/(lb F) ................kJ/(kg K) ..................4.1860BTU/(sq.ft h) ............kcal/(m2 h) ................2.713Wh/(m2h) ................kcal/(m2 h) ................0.8604BTU/(sq.ft h) ............Wh/(m2 h) ................3.154BTU/(sq.ft h F/in) ....kcal/(m h C) ............0.124W/(m K) ..................kcal/(m h C) ............0.860BTU/(sq.ft h F/in) ....W/(m K)....................0.1442BTU/(ft h F)..............W/(m K)....................1.7304BTU/(sq.ft h F) ........W/(m2 K) ..................5.677
TEMPERATURE CONVERSIONF to C first deduct 32, Multiply by 5 then Divide by 9C to F Multiply by 9, Divide by 5, Add 32
conversion tablefrom to multiply by from to multiply by
con
ten
ts
foreword . . . . . . . . . . . . . . . . page 04
company profile . . . . . . . . . . . . . . . . page 05
company statements . . . . . . . . . . . . . . . . page 06
welcome . . . . . . . . . . . . . . . . page 07
products . . . . . . . . . . pages 08 - 101
index a - z . . . . . . . . . pages 104 - 105
conditions of sale . . . . . . . . . . . . . . . page 106
conversion table . . . . . . . . . . . . . . . page 107
3
contents
DisclaimerThe information, recommendations and opinions set forth herein are offered solely for yourconsideration and are not, in part or total, to be construed as constituting a warranty orrepresentation for which IMS assume legal responsibility.
the a-z of insulation
the
a-z o
f insu
latio
n
the
a-z
of
insu
lati
on
the a-z of insulation
4
fore
wo
rd
foreword
If you require technical advice, or have any
queries whatsoever, then please call our sales
staff whom will be only too pleased to assist with
your enquiry.
Sales Line +44 (0) 1704 226 878
welcome to our comprehensive catalogue. Our products are for use within thermal and electrical applications in
all areas of industry. These quality products coupled with our
machining expertise, distribution network, and vast industry
experience, provide you with an unrivalled service.
5com
pan
y p
rofile
several locations in theUK and outlets throughout the
world, ensure IMS is able to
supply materials and technical
support on a worldwide basis,
when and where, you the
customer require our assistance.
With over forty years service to
industry, IMS is well placed to
offer a vast product range for all
applications, supported by
experienced and trained
personnel. Our machine shop is
fully equipped with the latest
state of the art CNC machinery,
including machining centres,
mil ls, routers, lathes, saws,
presses and sanders.
Recent acquisitions have also
added vacuum forming, ceramic
fibre board production and pre-
casting to our manufacturing
portfolio.
ims works in conjunctionwith many of the worlds
leading manufacturers/suppliers
of insulation products. With this
joint support you can be
assured that you wil l be
receiving products of
outstanding quality with full
manufacturers support.
ims is committedto the customerand our abil ity to rapidly
respond to customer
requirements will always remain
our priority and has been a
leading factor in the success of
our company to date. The
outstanding growth of IMS is
testament to the belief our
customers have in our company,
its products and the service we
provide.
ims specialise in the manufacture, machiningand supply of high temperature insulation
materials and components for use throughout
industry world-wide.
company profile
the a-z of insulation
the
a-z o
f insu
latio
n
Sales Line +44 (0) 1704 226 878
Sales Line +44 (0) 1704 226 878
the
a-z
of
insu
lati
on
the a-z of insulation
6
com
pan
y s
tate
men
ts
missionThe worlds need for insulation materials to conserve
energy and improve on current production methods is
growing steadily day-by-day. Materials used safely and
efficiently, are an integral part of manufacturing in
every country and every region in the world. Our goal
is to play a leading role in improving material
performances without damaging the environment.
Ours is a positive and progressive involvement.
Innovation will be the hallmark of the way we work
with people, technology, assets and relationships. We
will always be constructive, using our know-how to
produce effective and creative solutions to every
challenge. Our success depends on our making, and
being seen to make, a distinctive contribution to every
activity in which we are involved.
environmentalIMS has access to the widest range of thermal and
electrical insulation materials within our market
sectors. Therefore it is our aim to have in our portfolio
the safest alternatives to all potentially hazardous
materials, so that where required, we can help to
minimise the exposure to our customers and our
employees. Further, we continuously seek to reduce
the impact to the environment by reducing/removing
hazardous waste products, as well as in recycling
product where possible. IMS wish to contribute to a
safer, healthier working environment for all our
futures.
qualityThe quality policy of IMS is to consistently manufacture
and supply products which meet the companys
determined specifications, standards and criteria in
every respect.
The specifications, standards and criteria adopted by
the company conform to the highest levels in the
industry in which we operate. The company
continually examines the quality system employed to
ensure that the expectations and needs of the
customer are fulfilled.
The company fully realises that continuing success
depends upon the supply of high quality products and
service, and commits all employees to that end. All
employees are responsible for the implementation of
the techniques and for achieving specified levels of
quality and service at all stages of work.
The quality system is established to meet the
requirements of BS EN ISO 9001 (2000). The Quality
Assurance Manager is the companys management
representative entrusted with the day to day
responsibility for ensuring that the requirement of the
companys quality survey is met and maintained.
The company actively assists both suppliers and
customers in all areas of quality system controls, and
where at all possible the company only purchases
materials from internationally recognised quality
approved suppliers. The levels of control in these
standards are wholly appropriate to the manufacture
of all IMS products.
Giles HankinsonChief Executive Officerfor and on behalf of the IMS group of companies
company statements
Sales Line +44 (0) 1704 226 878 7
welco
me to
the im
sca
talo
gu
e
manufactured
ims manufacture a full range of
vacuum formed ceramic and RCF
free products. The range includes
boards, tubes, cones and special
shapes in materials able to
withstand up to 1600C.
ims manufacture a full range of
sewn textile and filtration products.
ims manufacture pre-cast
refractory shapes for al l
applications.
machined
ims offer comprehensive machining
facilities from four global locations.
Facilities include CNC machining
centres with CAD-CAM links, CNC
turning and mil l ing, cutting,
grinding, slotting, pressing and
almost every other conceivable
machining process available.
merchant
ims provide global distribution of
its own product range together
with those of the worlds leading
manufacturers. Multi-million $
stock levels at several global
locations ensure rapid delivery
when required.
methods of payment1. credit account - if you do not have anaccount with us, please phone for details
2. credit cards - we accept Visa, Mastercardand Switch/Delta
3. cash or cheque payment- please allow clearance time
welcome to the ims cataloguethe most comprehensive catalogue of insulation materials and associated
products available to you, from any one source.
phone: +44 (0)1704 226 878
fax: +44 (0)1704 225 857
email: [email protected]
the a-z of insulation
the
a-z o
f insu
latio
n
emergency serviceour unique breakdown facility offers you the peace of mind to know that if required we can
provide an emergency breakdown service, which in effect means that you can pass the worries
of your problem to us.
orderingyou choose the method of ordering that is suitable to your business. Our staff are on hand to take your orders and
also help you with any enquiries or product queries. Alternatively you can fax or e-mail your enquiry or order to us at
the numbers listed throughout this book.
productsims are committed to bringing you the most comprehensive and advanced range of products available from the
worlds leading manufacturers, together with good value and excellent quality own brand products.
services
the
a-z
of
insu
lati
on
the a-z of insulation
8
cera
mic
fib
re b
lan
ket
ceramic fibre blankettypical applications
Ceramic Industry Kiln car insulation and seals Continuous and batch kilns
Steel Industry Heat treating and annealing furnaces Furnace door linings and seals Soaking pit covers and seals Furnace hot face repairs Reheating furnace and ladle covers
Refining and Petrochemical Reformer and pyrolysis lining Tube seals, gaskets and expansion joints High temperature pipe, duct and
turbine insulation Crude oil heater linings
Power Generation Boiler insulation Boiler doors Reusable turbine covers Expansion seals/pipe coverings
Others Insulation of commercial dryers and ovens Veneer over existing refractory Stress relieving insulation Glass furnace crown insulation Fire protection
features
low thermal conductivity very low heat storage very high tensile strength thermal shock resistance sound absorption quick repairs. Should lining damage occur,
furnace can be cooled quickly contains no binder, no fumes or furnace
atmosphere contamination contains no asbestos no curing or dry out time, lining can be fired
to operating temperature immediately
Ceramic fibre blanket is composed of long, flexible,interwoven fibres manufactured by the "blown" andthe "spun" process yielding a strong,lightweight yet durable blanket forapplications in a temperaturerange from 538C (1000F ) to1480C (2700F).
Ceramic fibre blanket hasthe heat resistance of ahard refractorywith five timesbetter insulationvalue and the followingfeatures:
product link
p14: ceramic fibre adhesive
p15: rigidizer
p16: ceramic fibre mastic
technical data
cut sizes roll
LT RT HP HTZ HT
Maximum Use Temperature C 1000 1260 1315 1425 1482Maximum Use Temperature F 1800 2300 2400 2600 2700
THERMAL SHRINKAGE (%)24 Hrs @ 1000C 2.0 24 Hrs @ 1100C 2.0 1.8 24 Hrs @ 1300C 0 2.0 2.0
CHEMICAL ANALYSIS (%)AL2O3 42 - 46 46 - 48 44 - 50 33 - 37 52 - 54SiO2 50 - 60 49 - 55 50 - 56 47 - 51 42 - 46ZrO2 13 - 19 Fe2O3 0.7 - 1.5 0.8 - 1.2 0.1 - 0.2 0.1 - 0.2 0.1 - 0.2TiO2 1.5 - 1.9 1.5 - 1.9 0.1 - 0.2 0.1 - 0.2 0.1 - 0.2
DENSITY 64, 96 & 128 kg/m3 (4, 6,& 8 lbs/ft3)
All data represents typical results of standard tests conducted under controlled conditions. As such, the information is intendedonly as a general guide for specifications and design estimates.
HP and HTZ are manufactured by the "spun" process. This process produces long fibres that give our fibre products more strength. LT, RT & HT are manufactured by the "blown" process which produces a finer, softer blanket ideal for applications such as molding
around investment casting forms.
format dimensions
sales line +44 (0) 1704 226 878
thickness length width6mm 29.28m 610/1220mm13mm 14.64m 610/1220mm25mm 7.32m 610/1220mm38mm 4.80m 610/1220mm50mm 3.66m 610/1220mm
*1220mm width available to special order.
sales line +44 (0) 1704 226 878 9
cera
mic fib
re p
ap
er
dimensions
thickness length width1mm various 500/610/1220mm2mm various 500/610/1220mm3mm various 500/610/1220mm4mm various 500/610/1220mm5mm various 500/610/1220mm6mm various 500/610/1220mm8mm various 500/610/1220mm10mm various 500/610/1220mm
length and width of ceramic paper in stock may vary from time to time.
product link
p14: ceramic fibre adhesive
p15: rigidizer
technical data
format
sheet
gasket
roll
cut pieces
typical applications
Asbestos paper replacement Investment cast mold wrap insulation One-time consumable insulating applications Back-up lining for metal troughs Hot top lining Applications where low binder content is
required Thermal and electrical insulation Upgrade for fibreglass paper and blanket
products
features
easy to cut, wrap or form temperature stability low thermal conductivity low heat storage resilient lightweight thermal shock resistant good dielectric strength high fired tensile strength good flame resistance
MELTING POINT 1760C (3200F)
MAXIMUM USE TEMPERATURE 1260C (2300 F)
CHEMICAL ANALYSIS (%)Al2O3 46.50% SiO2 53.40% Others 0.10% L.O.I. 6%
DENSITY kg/m3 (lbs/ft3) 160 (10)
DIELECTRIC STRENGTH (Volts/mil) 50
TENSILE STRENGTH g/in 1/16" 1/10" 1/8" 1/4"
MACHINE DIRECTION 2700 3500 5000 13050
CROSS DIRECTION 2500 3100 5000 8000
Ceramic fibre paper, is a lightweightrefractory material processed from ablend of high purity alumina-silicafibres into a highly flexible,uniform sheet. It isrecommended forcontinuous use attemperatures up to1260C (2300F ).
Ceramic fibre paper, has lowshrinkage, good handling strength,and low thermal conductivity. It containsa small amount of organic binder for processing whichmakes it flexible, yet reduces off-gassing and odourduring use. Our product has a highly uniform structuredue to its controlled basis weight and thickness,assuring homogeneous thermal conductivity and aclean, smooth surface ideal for gasketing or sealing.
Ceramic fibre paper is completely free of asbestos andis designed to be an economic replacement forasbestos paper in most applications.
Ceramic fibre paper is easy to handle and is readily cutwith a knife, shears, or standard steel rule dies. Itsflexibility allows it to be wrapped or rolled to fit mostcomplex configurations.
Data are average results of test conducted under standard procedures and are subject to variations. Results should not be used for specification purpose.
the a-z of insulation
the
a-z o
f insu
latio
n
ceramic fibre paper
the
a-z
of
insu
lati
on
the a-z of insulation
10
cera
mic
fib
re b
oard
ceramic fibre board
product link
p14: ceramic fibre adhesive
p15: rigidizer
p16: ceramic fibre mastic
format
sheet cut pieces
dimensions
lengths:width:
thickness:
Ceramic fibre board is a lightweight refractory materialprocessed with alumina-silica fibres for applications attemperatures up to 1600C (2900F).
Ceramic fibre board is a vacuum formed product thatresists higher gas velocities than ceramic fibre blanket.It is ideal for furnace, boiler duct and stack lining dueto its low thermal conductivity and low heat storageallowing shorter cycle times and quicker access formaintenance.
technical data
1260 1260 1260 1400 1600LD MD HD LD LD
MAXIMUM USE LIMIT
C 1260 1260 1260 1426 1600F 2300 2300 2300 2600 2900
CONTINUOUS USE LIMIT
C 1149 1149 1149 1316 1426F 2100 2100 2100 2400 2600
MELTING POINT
C 1732 1732 1732 1780 1850F 3150 3150 3150 3236 3362
DENSITY lbs/ft3 14 - 18 20 - 24 26 - 30 14 - 18 14 - 18kg/m3 225 - 290 320 - 385 415 - 480 225 - 290 225 - 290
THERMAL SHRINKAGE (%)
24 hours @ 2200 F 2 - 3 1 - 2 1 - 2 1 - 2 1 - 2
THERMAL CONDUCTIVITY (W/mK)(Btu in/hr ft2 F)
316C (600F) 0.06 0.5 0.07 0.6 0.10 0.9 0.06 0.5 0.06 0.5538C (1000F) 0.07 0.6 0.08 0.7 0.11 1.0 0.07 0.6 0.07 0.6760C (1400F) 0.09 0.8 0.10 0.9 0.13 1.2 0.09 0.8 0.09 0.81094C (2000F) 0.13 1.2 0.13 1.2 0.16 1.4 0.13 1.2 0.13 1.2
CHEMICAL ANALYSIS (%)
AL2O3 39 - 41 45 - 47 43 - 45 48 - 50 63 - 65SiO2 52 - 54 44 - 46 47 - 49 45 - 47 32 - 34Others 2 - 3 2 - 3 2 - 3 1 - 2 1 - 2
Organic materials presented in the board will burn out at about 150C, once these materials have burned out there will be little or nofurther out gassing. All data represents typical results of standard tests conducted under controlled conditions. As such theinformation is intended only as a general guide for specifications and design estimates.
features
low thermal conductivity, saves fuel very low heat storage, faster heat and
cool-down reducing cycle times light weight. Replaces heavy back-up
insulation. Less steel required excellent thermal shock resistance resistant to hot gas erosion resists most chemical attacks easy to cut, handle and install low sound transmission resists penetration by molten aluminum and
other non-ferrous metals contains no asbestos
typical applications
Refractory lining for industrial furnaces inwalls, roofs, doors, stacks, etc
Combustion chamber liners, boilersand heaters
Back-up insulation for brick andmonolithic refractories
Transfer of molten aluminum and other non-ferrous metals
Expansion joint boards Barrier against flame or heat Hot face layer for high velocity or abrasive
furnace atmosphere
1000, 1220mm500, 610, 1000mm6, 10, 12, 15, 20, 25, 50, 75, 100mm
sales line +44 (0) 1704 226 878
Sales Line +44 (0) 1704 226 878 11
cera
mic fib
re b
ulk
ceramic fibre bulk
product link
n/a
technical data
format
20kg bag
25kg bag
40kg bag
dimensions
n/a
features
low thermal conductivity low heat storage excellent thermal shock resistance use limit to 1482 C (2700 F) low sound transmission contains no asbestos
RT HP HTZ HT
Maximum Use Temperature C 1260 1315 1425 1482Maximum Use Temperature F 2300 2400 2600 2700
THERMAL SHRINKAGE (%) 24 Hrs @ 1000C (1800F) 2.0 24 Hrs @ 1100C (2000F) 2.0 1.8 24 Hrs @ 1300C (2400F) 2.0
CHEMICAL ANALYSIS (%) AL2O3 46-48 44-50 33-37 52-54SiO2 49-55 50-56 47-51 42-46ZrO2 13-19 Fe2O3 0.8-1.2 0.1-0.2 0.1-0.2 0.1-0.2TiO2 1.5-1.9 0.1-0.2 0.1-0.2 0.1-0.2
All data represents typical results of standard tests conducted under controlled conditions. As such, the information is intended onlyas a general guide for specifications and design estimates.
the a-z of insulation
the
a-z o
f insu
latio
n
Ceramic fibre bulk is produced by the fusion of highpurity alumina-silica raw materials in an advancedelectric arc furnace. The fibres produced areexceptionally clean and consistent in quality andtexture.
Ceramic fibre bulk fibres are loose, long and flexiblewith high refractory properties, and are produced bythe "blown" and the "spun" processes. They are usedas the base for the production of blanket, moldable,and vacuum formed board and shapes.
typical applications
Packing expansion joints in hightemperature furnace
Low mass kiln cars Vacuum formed and moldable products Ladle insulation
the
a-z
of
insu
lati
on
the a-z of insulation
12
cera
mic
fib
re m
od
ule
s
ceramic fibre modules
product link
p14: ceramic fibre adhesive
p15: rigidizer
dimensions
dim A:
dim B:
dim C:
305, 610mm
305, 610mm
100, 150, 200, 250, 300mm
technical data
features
fast and easy installation lower heat storage and
fuel costs this design creates a
very light lining, lesssteel required
several anchor systems
typical applications
Ceramic Industry Low mass kiln cars Continuous and
batch kilns Door linings Glazing, porcelain
furnace linings
Power Generation Duct lining Heat recovery
steam system Boiler insulation Stack linings
Refining and Petrochemical Ethylene furnace roof
and walls. Pyrolysis furnace lining. Reformer furnace roof
and walls. Boiler linings
Others Incineration equipment Burner blocks Induction furnace covers Glass tempering furnace.
Steel Industry Ladle pre-heaters
and covers Heat treat furnace Soaking pit covers
and seals Heaters and
reformer liningRT HP HTZ HT Use Temperature C 1260 1315 1425 1482Use Temperature F 2300 2400 2600 2700
THERMAL SHRINKAGE (%) 24 Hrs @ 1000C 24 Hrs @ 1100C 2.0 1.8 24 Hrs @ 1300C 2.0 2.0
CHEMICAL ANALYSIS (%)AL2O3 46-48 44-50 33-37 52-54SiO2 49-55 50-56 47-51 42-46ZrO2 13-19 Fe2O3 0.8-1.2 0.1-0.2 0.1-0.2 0.1-0.2TiO2 1.5-1.9 0.1-0.2 0.1-0.2 0.1-0.2
DENSITY 160 & 192 kg/m3 (10 & 12 lbs/ft3)Standard Dimensions: Special sizes are available for specific needs
Sales Line +44 (0) 1704 226 878
Modules have the highest insulating valueachievable in a ceramic fibre. Each module isa continuous folded blanket undercompression.
Module linings prevent heat loss, increasingthe furnace productivity and reducingmaintenance costs.
Sales Line +44 (0) 1704 226 878 13
ceramic fib
re vacuu
m fo
rmed
shap
es
ceramic fibre vacuum formed shapes
product link
n/a
format
bespoke
dimensions
n/a
features
low thermal conductivity saves fuel low heat storage, reduces cycle times lightweight excellent thermal shock resistance resistant to hot gas erosion resists most chemical attacks easy to cut, handle and install resists penetration by molten aluminum and
other non-ferrous metals contains no asbestos
typical applications
Tundishes, melting crucibles and hot topsfor alloy melting
Heat insulation for industrial heaters Small furnaces Riser sleeves for foundries Head boxes and launders for continuous
sheet casting Die casting ladles Combustion Chambers
technical data
Available on request.
Ceramic fibre vacuum formed shapes are available in awide variety of shape configurations. These shapes areprocessed from alumina-silica fibres for applications attemperatures up to 1600C.
Vacuum formed shapes are manufactured to specificapplications, material compositions can be varied withdifferent fillers and chemicals to produce specialcharacteristics such as high strength, density andmolten metal non-wetability.
the a-z of insulation
the
a-z o
f insu
latio
n
the
a-z
of
insu
lati
on
the a-z of insulation
14
cera
mic
fib
re a
dh
esi
ve
Sales Line +44 (0) 1704 226 878
product link
p8: ceramic fibre blanketp9: ceramic fibre paperp10: ceramic fibre boardp12: ceramic fibre modulesp13: vacuum formed shapes
format
5kg tub
25kg tub
application data
features
high temperature air setting easy application creates surface hardening increases abrasion
resistance
typical applications
Surface coating
At high temperature thecement forms a hard egg-shell ceramic film on mostclean and grease freesurfaces. This film iscompletely stable. Themajority of ceramic fibreproducts may be coatedwith ceramic fibreadhesive as a protectionagainst high gas velocitiesor against molten metalcontact.
Bonding
Ceramic fibre adhesive isrecommended as a hightemperature adhesive tobond ceramic fibreproducts together, or toattach them to porousrefractory surfaces such asinsulating fire brick orinsulating concretes.
Ceramic fibre adhesive can be applied by brushing, dipping orspraying. Surfaces should be free of grease,dirt and dust. The coatingthickness on solid surfaces should be as thin as possible, followed bydrying at temperatures up to a maximum of 90C. The viscosity of thecement can be reduced, if required, by the addition of small quantitiesof clean tap water.
technical data
CLASSIFICATION TEMPERATURE C 1400
PROPERTIES MEASURED @ AMBIENT CONDITIONS 23C/50% RH
COLOUR white
DENSITY kg/m3 1840-1950
COMPRESSIVE STRENGTH MPa 45
HIGH TEMPERATURE PERFORMANCESpecific heat capacity at 100-550C kJ/kg.K 1.04-1.14Melting temperature after drying C 1760Permanent linear shrinkage after 24 hours at1000C % 2.151260C % 3.2
dimensions
n/a
Ceramic fibre adhesive is a high temperature, air setting cement for usemainly as a refractory surface coating, although generally used on ceramicfibre substrates it can also be used on porous materials such as insulatingfire brick and insulating concretes and will equally enhance their abrasiveresistance. The cement sets to form a strong hard film, which develops aceramic bond at high temperatures yet maintains excellent resistance tothermal shock. The maximum recommended surface temperature is1400C. It can also be used as an adhesive for ceramic fibre products.
ceramic fibre adhesive
Sales Line +44 (0) 1704 226 878 15
rigid
izer
rigidizer
product link
p8: ceramic fibre blanketp9: ceramic fibre paperp10: ceramic fibre boardp12: ceramic fibre modulesp13: vacuum formed shapes
format dimensions
n/a
technical data typical applications
Ceramic furnaces Oil heaters Petrochemical heaters Steel treatment furnaces Molten metal
transportation
MAXIMUM USE LIMIT 980C 1800F
BULK DENSITY - As Shipped 1.21g/cc 75lbs/ft3
WEIGHT per Gallon (5 Litres) 4.5kg 10lb
COVERAGE Per 5 litres Approximately
Area Brushed 5m2 50ft2
Area Sprayed 10m2 100ft2
COLOUR Bluish-White
SPECIFIC GRAVITY At 25C (77F) 1.21
VISCOSITY At 25C (77F) 5 Centipoise
ph 9.8
SHELF-LIFE 1 year
CHEMICAL ANALYSIS (%)Silica SiO2 +99% Alkali Na2O 0.32% Sulfates as NA2SIO4 0.04% Chlorides as NaCI 0.01%
The test data shown above are based on average results of control test and are subjectto normal variations on individual test. These results cannot be taken as maximum orminimum requirements for specification purpose.
Rigidizer is applied to the surface of ceramic fibreblanket, or other high temperature ceramic fibreinsulations by spraying or brushing. After air-drying,ceramic fibre rigidizer firms-up the refractory ceramicfibre, giving it tougher, more abrasion resistantcharacteristics. It is normally applied after the ceramicfibre is installed.
Rigidizer can be shipped in 5 litre or 25 litre plasticdrums. 5 litres of rigidizer covers approximately 5m2brushed or 100 square feet when sprayed.
the a-z of insulation
the
a-z o
f insu
latio
n
5litre tub
25litre tub
the
a-z
of
insu
lati
on
the a-z of insulation
16
cera
mic
fib
re m
ast
ic
Sales Line +44 (0) 1704 226 878
ceramic fibre mastic
product Link
p8: ceramic fibre blanketp9: ceramic fibre paperp10: ceramic fibre boardp12: ceramic fibre modulesp13: vacuum formed shapes
technical data
format
5kg tub
25kg tub
50kg tub
500mlcartridge
dimensions
n/a
typical applications
To form troughs or liners for non-ferrousmetal transfer
Gaskets and seals around burner blocks Protection of metallic parts from heat Pump into voids in badly damaged back-up
insulation Gaskets and seals for chimneys and stacks Boiler doors seals and thermal insulation To fill voids and cracks in refractory surface
features
low thermal conductivity low heat storage reduces fume emission around refractory excellent thermal shock resistance resistance to gas velocity easy to install adheres to most ceramic and metallic
surfaces excellent corrosion resistance inert to most chemicals impermeable to molten aluminum, zinc,
copper, lead contains no asbestos ready to use
MAXIMUM USE LIMIT 1200 C (2190 F) 1600C (2900F)
DENSITY (kgs/m3) Wet 1050 - 1230 1400 - 1600Dry 705 - 740 900 - 1100
THERMAL SHRINKAGE (%)24 hrs @ 1093 C (2000 F ) 2.8 2.6
THERMAL CONDUCTIVITY W/m2K BTU-in hr Ft2F W/m2K BTU-in hr Ft2F500F 0.06 0.5 0.06 0.51000F 0.12 1.0 0.12 1.01500F 0.15 1.2 0.15 1.2
CHEMICAL ANALYSIS (%)AL2O3 40 - 42 66SiO2 55 - 57 33Fe2O3 Trace TraceMgO Trace TraceK2O Trace TraceOther 2 - 3 Trace
Ceramic fibre mastic is used to prevent heat losscaused by the deterioration of the existing lining andcan be installed using a trowel, a caulking gun or apump.
Ceramic fibre mastic is a multipurpose form of ceramicfibre dispersed in a sticky, cohesive binder system thatadheres to most ceramic and metallic surfaces.
Ceramic fibre mastic is available in two forms, 1200Cand 1600C.
Mastic is normally applied with trowel, spatula or othersuitable tooling.
17
sup
erm
ag
bo
dy so
lub
le b
lan
ket
Sales Line +44 (0) 1704 226 878
supermagbody soluble blanket
product link
n/a
technical data
format
cut sizes roll
typical applications
Aluminium homogenizing furnace linings Back-up insulation for dense refractory Annealing furnace linings Stress relieving blankets Heat treatment furnace linings Crude heater linings Co-generation duct linings Reusable insulation pads Expansion joints
features
low thermal conductivity very low heat storage very high tensile strength thermal shock resistance low weight excellent corrosion resistance
MAXIMUM USE LIMIT 1200C 2200F
THERMAL SHRINKAGE %24 Hrs @ 850C (1562F) < 124 Hrs @ 1000C (1832F) 1.124 Hrs @ 1100C (2012F) 1.2
CHEMICAL ANALYSIS (%)
SiO2 58 - 65CaO 29 - 34SiO2 58 - 65MgO 3 - 5AL2O3 0.5 - 0.8Fe2O3 0.3 - 0.5
DENSITY 64, 96 + 128 kg/m3 (4, 6, 8 lbs/ft3)
All data represents typical results of standard tests conducted under controlled conditions. As such, the information is intendedonly as a general guide for specifications and design estimates.
This product is exonerated from any carcinogen classification in the countries of the European Union under provisions of nota Q ofEuropean Commission Directive 97/69/EC.
dimensions
thickness length width6mm 29.28m 610/1220mm13mm 14.64m 610/1220mm25mm 7.32m 610/1220mm38mm 4.80m 610/1220mm50mm 3.66m 610/1220mm
*1220mm width available to special order.
Supermag blanket is a high temperature bodysoluble fibre that utilises a unique spinningtechnology to create a special fibre with superiorthermal and mechanical properties. This specialfibre is made from a blend of calcium, silica andmagnesium having the abil ity to supportcontinuous temperatures up to 1200C.
the a-z of insulation
the
a-z o
f insu
latio
n
the
a-z
of
insu
lati
on
the a-z of insulation
18
cera
mic
fib
re m
ois
t fe
lt
Sales Line +44 (0) 1704 226 878
product link
p14: ceramic fibre adhesive
p15: rigidizer
p16: ceramic fibre mastic
format
roll
dimensions
lengths:
width:
thickness:
1000mm
610mm
6, 12, 25mm
ceramic fibre moist felt
technical data
MAXIMUM USE TEMPERATURE 1000C
MELTING POINT 1790C
COLOUR White
DENSITY (when dry) Kg/m3 200-300
TENSILE STRENGTH PSI Wet 17Dry 50
features
excellent velocity resistance high strength excellent insulation properties excellent resilience
typical applications
Insulation of complex shapes Hot face layer for kilns and furnaces
Ceramic fibre moist felt is made from high-strengthceramic fibre blanket impregnated with an inorganicrigidizing agent that hardens when exposed to air.
Moist felt is ideal for insulation of complex shapes asit retains the shape to which it has been mouldedafter it dries.
The product is packed in a clear polythene bag tomaintain the wet binder during shipment and prior to
use. Care should be taken when handling the packedproduct as damage to, or freezing of the packagingcan activate the drying process or make the materialunusable.
Curing of the product can be accomplished by airdrying over a period of several days or by immediateexposure to temperature in the application. Curing ofthe product simply removes the water content fromthe inorganic binder.
chemical analysis - calcined basis
Aluminium Oxide Al2O3 25-35%Silica SiO2 65-75%Alkali Na2O
19
saffil
the a-z of insulation
the
a-z o
f insu
latio
n
Sales Line +44 (0) 1704 226 878
product Link
p14: ceramic fibre adhesive
p15: rigidizer
p16: ceramic fibre mastic
format
as stated above.
dimensions
as stated above.
technical data
BLANKET MAT BULK
MAXIMUM USE LIMIT 1600C 1600C 1600C
PROPERTIES MEASURED AT AMBIENT (23C/50% RH) Colour White White WhiteSolubility in water Insoluble Insoluble InsolubleOdour Odourless Odourless OdourlessFibre Diameter (Median) Micron 3.0 - 3.5 3.0 - 3.5 3.0 - 3.5Shot content (Non fibrous material) negligible negligible negligibleTensile Strength MPa 2000
PROPERTIES WHEN EXPOSED TO HIGH TEMPERATUREMelting Point C >2000 >2000 >2000Shrinkage (6 Hours @ 1500C) %
the
a-z
of
insu
lati
on
the a-z of insulation
20
cera
mic
fib
re r
op
es,
tap
es
& t
exti
les
ceramic fibre ropes, tapes & textiles
product link
p14: ceramic fibre adhesive
p15: rigidizer
p16: ceramic fibre mastic
format
see opposite page.
dimensions
see above.
types available
Yarn Cloth Cabled rope (high density) Cabled rope (low density) Rope lagging Twisted rope Webbing Ladder tape
classification temperature
Alumino-Silicate: 1260CInconel Wire: 1100CGlass Filament: 550C
dimensions
SECTION TWISTED CABLED ROPE CABLED ROPE ROPE WEBBINGmm Rope (High density) (Low Density) Lagging Width (mm) Thickness (3mm)
roll lengths
4 200 25 256 100 100 40 259 50 50 50 25 50 2512 50 50 50 75 2513 25 100 2515 50 50 50 2519 25 LADDER TAPE20 25 25 25 Width (mm) Roll Length (m)25 25 25 2530 25 25 25 2538 40 2540 20 20 50 2550 20 20 25 75 2575 25 100 25
Ceramic fibre ropes, tapes & textilesA wide variety of textiles are produced either byconverting ceramic blanket or by processing refractoryceramic fibre yarn into woven products. A variety ofproduct forms can be produced.
Ceramic fibre textiles are suitable for use at elevatedtemperatures approaching 1400C, maintainingflexibil ity for use in thermal sealing and fi l l ingapplications in areas such as door seals, expansionjoints and gland packings.
Sales Line +44 (0) 1704 226 878
Sales Line +44 (0) 1704 226 878 21
cera
mic fib
re ro
pes, ta
pes &
textile
s
the a-z of insulation
the
a-z o
f insu
latio
n
TYPES AVAILABLE
YarnYarn is manufactured from ceramic fibre. This yarn isthe base of all the ceramic textile range of products.The yarn is reinforced with either a glass filament or afine inconel wire.
ClothCloth is woven from a glass or inconel wire reinforced yarn.
Cabled rope (high density)High density cabled rope is manufactured from yarnwhich is either glass fi lament or inconel wirereinforced. It is composed of 3 pre-twisted strandseach containing a predetermined multiple of yarnswhich are twisted together to form a flexible, highdensity rope.
Twisted ropeTwisted rope consists of a multiple of ceramic yarnstrands which can be either glass filament or inconelwire reinforced. They are twisted together to give therequired final product diameter. This gives a soft ropeproduct that is relatively easily compressed and isparticularly suitable as a seal between uneven surfaces.
WebbingWebbing is woven from either glass or inconel wirereinforced ceramic yarn.
Ladder tapeLadder tape is woven from either glass or inconel wirereinforced ceramic yarn. It has a similar weave to clothon the outer edges, but an open weave in the centreallowing for ease of installation over studs. It is ideal as agasketing material.
Cabled rope (low density)Low density cabled rope is manufactured from ceramicroving which is glass fi lament reinforced. It iscomposed of 3 pre-twisted strands each containing apredetermined multiple of ceramics yarns which aretwisted together to form a flexible, low density rope.
Rope laggingRope lagging consists of a strip of ceramic blanket thatis overbraided with a glass yarn. This produces a highlyinsulating rope product of medium density, which isalso compressible and flexible. As an alternative, thisproduct could also be overbraided with either a cottonyarn or a fine inconel wire.
the
a-z
of
insu
lati
on
the a-z of insulation
22
dalf
rate
x
Sales Line +44 (0) 1704 226 878
chemical analysis - calcined basis
Silica SiO2 98.57%Alumina Al2O3 0.47%Iron Oxide Fe2O3 0.08%Lime CaO 0.05%Magnesia MgO 0.07%Titania TiO2 0.30%Alkalis Na2O + K2O 0.13%Boric Oxide B2O3 0.06%
features
low thermal conductivity low heat storage reduces fume emission around refractory excellent thermal shock resistance resistance to gas velocity easy to install adheres to most ceramic and metallic
surfaces excellent corrosion resistance inert to most chemicals impermeable to molten aluminum, zinc,
copper & lead contains no asbestos
DALFRATEX is a range of inorganic fibres and textilesthat are capable of operating continuously at 1000Cand up to 1600C for limited periods. They will not meltor vaporize until temperature exceeds 1700C, andhave a high resistance to thermal shock. DALFRATEXproducts also provide flexible electrical insulation attemperatures as high as 1000C. Products are availableas textile cloths, tapes, sleevings, cords, braidedpackings, ropes and also as bulk fibres and batts.
DALFRATEX products are composed of continuousfilaments of amorphous silica, which combine theflexibility of fibres and textiles, with the refractoryproperties of silica.
In order to service the needs of a wide range ofapplications the majority of DALFRATEX products areavailable in two basic forms: standard and pre-shrunk.The standard form shrinks during initial heating andproducts of this type have letter U incorporated intothe code number. As their name implies, the pre-shrunk forms have been factory treated to conferbetter dimensional stability in high temperature use.
In addition to these forms a wide range of sacrificialorganic finishes are available which may be applied toparticular products where required for specific end uses.
typical applications
Aerospace (gas turbine and rocket engines) Metallurgical/steel production Glass manufacture Fire protection Electrical heating Pipeline and vessel fabrication Gas production Nuclear power Electricity generation Petrochemical
dalfratextextile cloths, tapes, sleevings,cords, braided packings, ropes,bulk fibres & batts
23
dalfra
tex
the a-z of insulation
the
a-z o
f insu
latio
n
Sales Line +44 (0) 1704 226 878
product link
n/a
format
as above.
dimensions
technical data
Batt Data THICKNESS NOMINAL SURFACE NOMINAL LENGTH NOMINAL WIDTH NOMINAL BULKCODE NUMBER DENSITY (mm) DENSITY (g/m2) (m) (mm) (kg/m3)B-1 3.8 300 2.2 915 80B-2 6.3 600 2.2 915 96B-3 9.4 825 2.2 915 88B-4 12.5 1000 2.2 915 80B-8 25.0 2000 2.2 915 80Minimum Length 1.0m Maximum Length 2.7m
Cloth Data NOMINAL NOMINAL WIDTH NOMINAL WEIGHT YARN TYPE OFCODE NUMBER THICKNESS (mm) (mm) (g/m2) TYPE WEAVEC-H 0.9 825 630 Plain SatinC-19 1.6 825 1250 Plain SatinUC-H/D 0.9 910 640 Plain SatinUC-19/D 1.6 910 1260 Plain SatinUC-19/AR 1.7 910 1300 Plain SatinNominal Roll Length 45m
Rope Data NOMINAL NOMINAL WEIGHTCODE NUMBER DIAMETER (mm) (g/m)R-B3 9 70R-B4 12 110R-B6 19 230R-B8 25 385R-C10 10 40R-C13 13 60R-C25 20 to 25 60R-C40 40 260The B Series ropes are supplied in pre-shrunk condition and have a light coating applied to assist manufacture.The C series ropes are supplied pre-shrunk and without coating.
Cordage Data NOMINAL NOMINAL WEIGHT STANDARD NOMINAL NOMINAL LENGTHCODE NUMBER DIAMETER (mm) (g/m) PACKAGE PACKAGE per PACKAGE (m)D-T3 2.0 4000 100 D-T4 3.0 6200 50 D-T2 1.2 1200 0.25 210D-T20 0.9 740 0.25 340All cord can be supplied in pre-shrunk or in natural condition and are coated.
Tape Data NOMINAL NOMINAL WIDTH NOMINAL WEIGHT STANDARD PACKAGECODE NUMBER THICKNESS (mm) (mm) (g/m) (m)T-3 0.4 20 6 30T-5 0.4 30 9 30T-85 4.0 22 37 T-86 4.0 45 75 T-105 4.5 70 127 UT-124/50 3.5 50 Self AdhesiveT-H/25 1.0 25 16 T-H/50 1.0 50 32 T-H/75 1.0 75 48 T-19/25 1.6 25 32 T-19/50 1.6 50 63 T-19/75 1.6 75 94 UT-19/50 1.8 50 63
Sleeving Data NOMINAL NOMINAL WALL STANDARD INDICATIVE YIELDCODE NUMBER BORE (mm) THICKNESS (mm) PACKAGE (m) AT STATED DIAMETER (m/kg)S-R4 3.2 0.5 30 S-R6 4.8 0.5 30 S-R8 6.4 0.6 20 S-R25 20.0 1.0 15 S-R32 25.0 1.0 15 S-F16 10.0 0.4 30 S-F20 13.0 0.5 30 S-F25 20.0 0.5 20 S-F30 25.0 0.5 20 S-8 30.0 1.0 S-47 10.0 5.0 S-43 50 9 at 50mmS-44 65 to 75 9 at 65mmS-46 75 to 85 7 at 75mmAll sleevings can be supplied in pre-shrunk or in natural condition; with or without a coating.
Packaging Data NOMINAL APPROXIMATECODE NUMBER DIMENSIONS (mm) YIELD
DIAMETER (m/kg)UR-K12 12 23UR-K15 15 11UR-K19 19 15UR-K25 25 4.5
as above.
the
a-z
of
insu
lati
on
the a-z of insulation
24
filt
er
clo
th
filter cloth
Sales Line +44 (0) 1704 226 878
During molten aluminium production processes it isoften a necessity to fi lter the metal to removeimpurities, inclusions and dross prior to casting. Thefilter cloth products produced by ims assist in removingthese unwanted particles.
The filter cloth range of products consists of wovenglass fabrics coated with either phenolic resin or fineceramic slurry to ensure that the product maintains itsintegrity during use. There are many weave styles tochoose from and our technical staff are on hand todiscuss your requirements.
It is important to consider the production process whenselecting your fabric style. Long and/or aggressiveproduction processes normally require 4 or 6 strandwoven cloth styles whilst 3 strand woven cloth stylesperform satisfactorily in standard alloy production.
Combo Bagsaluminium slab and t bar casting processes oftendemand metal flow and heat dissipation control.Combo bags are the ideal consumable for this part ofthe production process.
For casting of aggressive alloys or long duration casting(long drop cycles), combo bags can be manufacturedwith a heavy duty construction to ensure the integrityof the combo bag is maintained until the end of the cast.
Filter SockDuring the aluminium billet casting processit is advisable to filter the molten metal whilstit transitions through the launder system. Afilter sock (sometimes called launder sock) isideal for this application.
During the casting process the filter sock is held in thelaunder system via loops sewn into the filter sock,which are hung over metal fixings attached to thelaunder metalwork or alternatively by being insertedbetween two launder sections. Should the filter sockbe inserted between launder sections it is necessary tohave a compressible high temperature gasket sewninto a flange at the open end of the filter sock toensure no metal leakage between the launder joints.
IMS offer filter cloths with a wide range of openareas to accommodate all process requirements.
25
filter clo
th
the a-z of insulation
the
a-z o
f insu
latio
n
product link
n/a
format
cut
bespoke
roll
roll dimensions
lengths:
width:
100m
915 - 1500mm
features
manufactured to your exact requirements ease of application low cost improves metal quality improves first time reject rate reduces metal turbulence
technical data
STYLE WEAVE TYPE STRANDS HOLES OPENING SIZE OPEN AREAper cm per cm2 mm2 %
L60 leno 18x18 4 16 60L55 leno 23x25 6 9 55L56 leno 27x27 7 7 56L40 leno 30x28 9 5 40P50 plain 35x35 12 4 50P48 plain 40x40 15 3 50P45 plain 36x36 13 3.5 45P40 plain 38x38 15 2.5 40P32 plain 50x46 22 1.5 32
Sales Line +44 (0) 1704 226 878
Foundry FiltrationDuring the casting process it is advisable to filter the molten metal. Filtercloth discs are ideal for this process. Due to the high risk of inclusions
causing rejects in the finished cast item it is advisable to use a filter clothdisc with an extremely low L.O.I. IMS have developed a filter cloth with less
than 2.0% L.O.I. for this particular process.
Consideration should be given to metal flow rate and cleanliness requirements prior to selecting filter cloth size.
typical applications
Launder sock/windsock filters Foundry filters Baffle bags Distribution bags Combo bags Spout socks Channel bags
the
a-z
of
insu
lati
on
the a-z of insulation
26
refr
act
ory
Insulating Castables and Gunmixes
IMS supply a comprehensive range of InsulatingCastables and Gunmixes which are generally used asback-up insulation behind a hot face material such as aDense or Low Cement Castable. Temperaturegradients, thermal efficiency, atmospheric conditionsand strength generally determine the choice ofmaterial along with the maximum service temperaturerequirement. Certain applications where temperatureand abrasion resistance are not an issue allow the useof insulation castable as a one shot hot face liningtherefore exhibiting excellent thermal characteristics.Materials can be installed by casting or gunningtechniques the method chosen is generally dependantupon application, access and cost.
Dense Castables and Gunmixes
IMS supply a comprehensive range of Dense Castablesand Gunmixes which exhibit excellent strength andabrasion resistance. These materials can be used as aone shot lining or more commonly as a hot facematerial with an insulation grade as a back up lining.Again application conditions form a major part in thecorrect choice of material, whatever the applicationIMS can supply a suitable material. The hot face liningis the working lining of the vessel therefore it isessential that the chosen material exhibits the requiredcharacteristics to obtain optimum life. Resistances tothermal shock, abrasion, chemical attack, reducingatmospheres are a few of the key factors determiningchoice of material along with the maximum servicetemperature requirement. Materials can be installed bycasting and gunning techniques. The method chosen isgenerally dependant upon access and cost.
Plastics and Ramming mixes
IMS supply a comprehensive range of Plastics andRamming mixes which are both clay and chemicallybonded materials, installed by ramming techniques.Clay bonded materials exhibit a good green strengthwhen allowed to air dry. Chemically bonded materialsform their strength during the curing or heattreatment process. The choice of material is dependantupon temperature, atmospheric conditions, chemicalattack and application; Phosphate or chemicallybonded materials show excellent resistance tochemical or slag attack. The coarse grained nature ofboth these generic materials allows for good abrasionand thermal shock resistance. They are ideally suitedfor use in restricted areas such as boilers, ladle linings& burner quarls.
Low Cement Monolithics
IMS supply a comprehensive range of Low CementMonolithics which exhibit extremely high hot strengthand abrasion resistance characteristics. These materialsare more technically advanced than the family ofdense castables and show low porosity and goodresistance to slags where molten metals attack therefractory. In addition to their excellent performancecharacteristics we have materials available for everyconceivable application; these materials are termedfree-flow materials which can be installed bypumping or casting. The term free flow means they donot need vibrating into position therefore aidinginstallation. We also offer a range of multi-purposeLow Cement Castables which can be pumped,vibrocast or act as a free flow material. The strict wateraddition determines the mode of installation.
Silicon Carbide mixes
IMS supply Silicon Carbide materials which by theirnature possess excellent volume stability right throughtheir temperature range along with high abrasionresistance and thermal shock characteristics. Thesematerials are designed as free flow materials toeliminate the need for vibrating the product into place;thus eliminating grain segregation and maintaining ahigh strength profile. These materials are designed forspecialist applications and can be installed by castingor pumping into place.
Mortars
IMS supply a range of exclusive mortars exhibitingboth high refractoriness and bond strength. We supplyboth dry and ready mixed materials depending uponpreference. The materials produced cater for a widetemperature range and for more arduous applicationswhere the materials are prone to attack and reducingatmospheres, we have a hybrid range of productswhich show excellent resistance to attack thereforeretaining their original integrity for extended periods.IMS mortars are renowned for their use in the mostexacting of environments.
refractory castables, gunmixes, mortars,plastics & rammings
27
pre
-castin
g
the a-z of insulation
the
a-z o
f insu
latio
n
pre-casting
Material selection
It is important to ensure the correct selection of rawmaterial prior to casting. When selecting raw materialconsideration should be given to the demands of theapplication. The choice of material can ultimately dependupon cost and relative performance, however thecomplexity and required surface finish together with thephysical volume of the cast shape can also bedetermining factor. Our technical staff are on hand tooffer advice should this be required.
Casting
Once material selection has been completed and themoulds have been produced casting of the shape isundertaken. IMS cast shapes using several castingtechniques including vibration, vibroflow, free-flow, andslip. Consideration is given to the material shrinkageduring the firing/drying process and the mould ismanufactured oversize to accommodate this effect.The firing/drying process removes any excess water fromthe shape before despatch.
Inspection and despatch
As soon as the shape has been passed by our inspectiondepartment it is shrink-wrapped to reduce moistureingress during transit and then made ready for customercollection or delivery.
IMS provide extensive pre-casting facilities.
Mould manufacturing
The mould type used in the casting process oftendetermines the finished quality of the fired shape. IMSprovide an in-house mould-making service, wheremoulds can be manufactured from polystyrene, wood,plastic, plaster and steel substrates. Customers cansupply their own pre-manufactured moulds into whichIMS cast the refractory. In these instances it may benecessary for us to refurbish or in certain cases replacethe existing mould.
Drying/Firing
Drying/Firing of the cast shape is carried out in our stateof the art kilning department. Following firing the castshape undergoes final inspection. Rigorous testingmethods following stringent internal controls ensure thatthe finished shape meets the customer requirements.
All casting processes undertaken by IMS follow processcontrols as set out in the company ISO 9001 (2000) policydocument available on request.
the
a-z
of
insu
lati
on
the a-z of insulation
28
exp
ress
30
Sales Line +44 (0) 1704 226 878
product link
p8 - 21: all ceramic productsp57: anchor systemsp59 - 60: sifca, FIBERstonep61 - 64: bricks
format
loose
dimensions
n/a
low cement castableexpress 30
chemical analysis - calcined basis
Silica SiO2 33.0%Alumina Al2O3 60.0%Iron Oxide Fe2O3 1.0%Lime CaO 3.0%Magnesia MgO 0.2%Titania TiO2 2.5%Alkalis Na2O + K2O 0.5%
Express 30 is a dense free flowing low cement castablerefractory suitable for use to 1650C. It has the uniqueproperty of not requiring vibration for placement or toremove air. It can be cast or pumped, to produce alining having a very good abrasion resistance.
Typical applications include FCCU transfer lines,cyclones, air heaters, aluminium furnace upper wallsand roofs, pre-cast shapes, burner blocks, rotary kilnlifter and mixer shapes, rotary kiln feed and dischargehoods, brass crucible furnace tops, brass reverbatoryfurnace upper sidewalls and roofs, vertical case ofchannel induction furnaces melting yellow brass,incinerators, high temperature boiler linings andcombustion chambers.
technical data
FREE FLOW CONSISTENCYMAXIMUM RECOMMENDED TEMPERATURE 3000F 1650C
QUANTITY REQUIRED Net 143 lb/ft3 2290 Kgs/m3
BULK DENSITY lb/ft3 Kgs/m3
Cured and then dried at 220F(105C) 144 - 153 2300 - 2450Heated at 1500F(820C) 144 - 153 2300 - 2450
WATER REQUIRED FOR MIXING ApproximatelyPer 100 Kgs 1.9 gal 8.5 Litres
MAXIMUM TIME FROM ADDING WATER TO PLACING MATERIALMinutes 45
PERMANENT LINEAR CHANGE ASTM C113 AND C865Expansion or ShrinkageCured and then dried at 220F(105C)
29
gre
en
kle
en
60
Sales Line +44 (0) 1704 226 878
the a-z of insulation
the
a-z o
f insu
latio
n
product Link
p8 - 21: all ceramic productsp57: anchor systemsp59 - 60: sifca, FIBERstonep61 - 64: bricks
low cement castablegreenkleen 60
chemical analysis - calcined basis
Silica SiO2 30.5 - 34.5%Alumina Al2O3 58.0 - 62.0%Iron Oxide Fe2O3 0.5 - 1.0%Lime CaO 2.5 - 4.0%Magnesia MgO Tr - 0.1%Titania TiO2 1.0 - 2.0%Alkalis Na2O + K2O 0.2 - 0.5%
Greenkleen 60 is a 60% alumina vibratable lowcement castable. Greenkleen 60 displays outstandingabrasion wear and thermal shock resistance.Greenkleen 60 is specifically designed for aluminumcontact and is formulated to be non-wetting by moltenaluminum.
Typical applications include furnace floors, lowersidewalls etc.
technical data
VIBRATED CONSISTENCYMAXIMUM RECOMMENDED TEMPERATURE 3000F 1650C
QUANTITY REQUIRED Net 155 lb/ft3 2470 Kgs/m3
BULK DENSITY lb/ft3 Kgs/m3
Cured and then dried at 220F(105C) 157 - 162 2515 - 2595Heated at 1500F(820C) 151 - 156 2419 - 2500
WATER REQUIRED FOR MIXING ApproximatelyPer 100 Kgs 1.2 gal 5.5 Litres
MAXIMUM TIME FROM ADDING WATER TO PLACING MATERIALMinutes 20
PERMANENT LINEAR CHANGE ASTM C113 AND C865Expansion or ShrinkageCured and then dried at 220F(105C)
the
a-z
of
insu
lati
on
the a-z of insulation
30
gre
en
tec
140
Sales Line +44 (0) 1704 226 878
product link
p8 - 21: all ceramic productsp57: anchor systemsp59 - 60: sifca, FIBERstonep61 - 64: bricks
low cement castablegreentec 140
chemical analysis - calcined basis
Silica SiO2 55.0%Alumina Al2O3 34.0%Iron Oxide Fe2O3 3.8%Lime CaO 4.0%Magnesia MgO 0.4%Titania TiO2 1.5%Alkalis Na2O + K2O 0.5%
Greentec 140 is a 35% alumina vibratable, low cementcastable suitable for use at temperatures up to1400C. It exhibits good density and low porosity, for aproduct of its type.
Greentec 140 is a 35% alumina general purposevibrating castable that can be used as an original liningmaterial or as a material to repair existing linings. It isused as pre-cast shapes in a range of applications.
technical data
VIBRATED CONSISTENCYMAXIMUM RECOMMENDED TEMPERATURE 2550F 1400C
QUANTITY REQUIRED Net 134 lb/ft3 2150 Kgs/m3
BULK DENSITY lb/ft3 Kgs/m3
Cured and then dried at 220F(105C) 134 - 137 2150 - 2200Heated at 1500F(820C) 133 - 136 2140 - 2180
WATER REQUIRED FOR MIXING ApproximatelyPer 100 Kgs 1.5 gal 7 Litres
MAXIMUM TIME FROM ADDING WATER TO PLACING MATERIALMinutes 20
PERMANENT LINEAR CHANGE ASTM C113 AND C865Expansion or ShrinkageCured and then dried at 220F(105C)
31
gre
en
tec 1
70 lg
the a-z of insulation
the
a-z o
f insu
latio
n
Sales Line +44 (0) 1704 226 878
product link
p8 - 21: all ceramic productsp57: anchor systemsp59 - 60: sifca, FIBERstonep61 - 64: bricks
low cement castablegreentec 170 lg
chemical analysis - calcined basis
Silica SiO2 22.6%Alumina Al2O3 72.7%Iron Oxide Fe2O3 0.8%Lime CaO 2.1%Others 1.8%
technical data
MAXIMUM RECOMMENDED TEMPERATURE 3100F 1700C
QUANTITY REQUIRED Net 143 lb/ft3 2300 Kgs/m3
BULK DENSITY lb/ft3 Kgs/m3
Cured and then dried at 220F(105C) 143 - 150 2300 - 2400Heated at 1500F(820C) 140 - 147 2250 - 2350
PERMANENT LINEAR CHANGE ASTM C113 AND C865Expansion or ShrinkageCured and then dried at 220F(105C)
the
a-z
of
insu
lati
on
the a-z of insulation
32
ult
ra g
reen
45
Sales Line +44 (0) 1704 226 878
low cement castableultra green 45
product link
p8 - 21: all ceramic productsp57: anchor systemsp59 - 60: sifca, FIBERstonep61 - 64: bricks
format
loose
dimensions
n/a
Ultra Green 45 is a ultra low cement castable suitablefor use at temperatures up to 1650C. It exhibits highdensity and low porosity, outstanding hot load bearingcapability and superior corrosion resistance.
Ultra Green 45 can be used as an original liningmaterial or as a material to repair existing linings. It isused in pre-cast shapes for a range of iron and steelapplications, non-ferrous furnaces and ladles. Othermarket applications include cement ki lns, andchemical processing.
technical data
VIBRATED CONSISTENCYMAXIMUM RECOMMENDED TEMPERATURE 3000F 1650C
QUANTITY REQUIRED Net 144 lb/ft3 2305 Kgs/m3
BULK DENSITY lb/ft3 Kgs/m3
Cured and then dried at 220F(105C) 140 - 148 2240 - 2370Heated at 1500F(820C) 140 - 148 2240 - 2370
WATER REQUIRED FOR MIXING ApproximatelyPer 100 Kgs 1.1 gal 5.0 Litres
MAXIMUM TIME FROM ADDING WATER TO PLACING MATERIALMinutes 20
PERMANENT LINEAR CHANGE ASTM C113 AND C865Expansion or ShrinkageCured and then dried at 220F(105C)
33
ultra
gre
en
57a
the a-z of insulation
the
a-z o
f insu
latio
n
Sales Line +44 (0) 1704 226 878
low cement castableultra green 57a
product link
p8 - 21: all ceramic productsp57: anchor systemsp59 - 60: sifca, FIBERstonep61 - 64: bricks
format
loose
dimensions
n/a
Ultra Green 57A is a 57% alumina, andalusite baseddense, ultra low cement castable suitable for use up to1650C.
Ultra Green 57A has outstanding thermal shockresistance in applications having extreme cyclictemperature conditions. Ultra Green 57A also featureshigh hot strength and low porosity equal tocomparable fired brick formulations.
technical data
VIBRATED CONSISTENCYMAXIMUM RECOMMENDED TEMPERATURE 3000F 1650C
QUANTITY REQUIRED Net 157 lb/ft3 2515 Kgs/m3
BULK DENSITY lb/ft3 Kgs/m3
Cured and then dried at 220F(105C) 156 - 164 2500 - 2630Heated at 1500F(820C) 156 - 161 2500 - 2580
WATER REQUIRED FOR MIXING ApproximatelyPer 100 Kgs 1 gal 4.7 Litres
MAXIMUM TIME FROM ADDING WATER TO PLACING MATERIALMinutes 20
PERMANENT LINEAR CHANGE ASTM C113 AND C865Expansion or ShrinkageCured and then dried at 220F(105C)
the
a-z
of
insu
lati
on
the a-z of insulation
34
ult
ra g
reen
80 a
l
Sales Line +44 (0) 1704 226 878
low cement castableultra green 80 al
product link
p8 - 21: all ceramic productsp57: anchor systemsp59 - 60: sifca, FIBERstonep61 - 64: bricks
format
loose
dimensions
n/a
Ultra Green 80 AL is an 80% alumina, vibratable ultralow cement castable. It has very high strength, highhot load bearing ability, low porosity and high density.Ultra Green 80 AL is specially formulated for resistanceto corrosion by molten aluminium.
Ultra Green 80 AL is specially designed for the severestaluminium contact applications.
technical data
VIBRATED CONSISTENCYMAXIMUM RECOMMENDED TEMPERATURE 3000F 1650C
QUANTITY REQUIRED Net 171 lb/ft3 2740 Kgs/m3
BULK DENSITY lb/ft3 Kgs/m3
Cured and then dried at 220F(105C) 174 - 180 2800 - 2890Heated at 1500F(820C) 170 - 175 2720 - 2800
WATER REQUIRED FOR MIXING ApproximatelyPer 100 Kgs 0.9 gal 4 Litres
MAXIMUM TIME FROM ADDING WATER TO PLACING MATERIALMinutes 20
PERMANENT LINEAR CHANGE ASTM C113 AND C865Expansion or ShrinkageCured and then dried at 220F(105C)
35
versa
flow
45 p
lus
the a-z of insulation
the
a-z o
f insu
latio
n
Sales Line +44 (0) 1704 226 878
product link
p8 - 21: all ceramic productsp57: anchor systemsp59 - 60: sifca, FIBERstonep61 - 64: bricks
chemical analysis - calcined basis
Silica SiO2 51.0%Alumina Al2O3 44.0%Iron Oxide Fe2O3 1.0%Lime CaO 2.3%Magnesia MgO 0.1%Titania TiO2 1.0%Alkalis Na2O + K2O 0.3%
technical data
VIBCASTINGMAXIMUM RECOMMENDED TEMPERATURE 2700F 1482C
QUANTITY REQUIRED Net 135 lb/ft3 2170 Kgs/m3
BULK DENSITY lb/ft3 Kgs/m3
Cured and then dried at 220F(105C) 136 - 139 2180 - 2220Heated at 1500F(820C) 134 - 136 2155 - 2180
WATER REQUIRED FOR MIXING ApproximatelyPer 100 Kgs 29 - 33 gal 6.2 - 7.1 Litres
PERMANENT LINEAR CHANGE ASTM C113 AND C865Expansion or ShrinkageCured and then dried at 220F(105C) negligibleHeated at 1500F(820C) and then cooled 0.1% ShrHeated at 2000F(1100C) and then cooled 0.4% Shr
MODULUS OF RUPTURE ASTM C133 AND C865 lb/in2 MPaCured and then dried at 220F(105C) 1020 - 1600 7.0 - 11.0Heated at 1500F(820C) and then cooled 1160 - 1740 8.0 - 12.0Heated at 2000F(1100C) and then cooled 1160 - 1740 8.0 - 12.0
COLD CRUSHING STRENGTH ASTM C133 AND C865Cured and then dried at 220F(105C) 6540 - 8720 45.0 - 60.0Heated at 1500F(820C) and then cooled 5810 - 7990 40.0 - 55.0Heated at 2000F(1100C) and then cooled 5810 - 7990 40.0 - 55.0
THERMAL CONDUCTIVITY W/mKat a Mean Temperature of 400F(205C) 1.34800F(425C) 1.391200F(650C) 1.461500F(820C) 1.542000F(1095C) 1.65
Versaflow 45 plus is a fireclay based low cementcastable for use in high abrasion environmentsup to 1482C. Good volume stability results inless shrinkage cracking in service.
Versaflow 45 plus is suitable for:
iron and steel foundries:reheat furnaces, forge furnace car decks. minerals processing:rotary ki lns l ifters, feed-end and chainsections, cooler walls. chemical processing industry:boiler applications, incineration (ash hoppers). aluminium:flue caps, pre-cast shapes for carbon bakefurnaces, subhearths and lower sidewallback-up castable.
low cement castableversaflow 45 plus
format
loose
dimensions
n/a
the
a-z
of
insu
lati
on
the a-z of insulation
36
vers
afl
ow
65/a
l c
ad
tech
Sales Line +44 (0) 1704 226 878
product link
p8 - 21: all ceramic productsp57: anchor systemsp59 - 60: sifca, FIBERstonep61 - 64: bricks
low cement castableversaflow 65/al c adtech
chemical analysis - calcined basis
Silica SiO2 26.5%Alumina Al2O3 66.5%Iron Oxide Fe2O3 1.0%Lime CaO 3.6%Magnesia MgO 0.1%Titania TiO2 2.1%Alkalis Na2O + K2O 0.2%
Versaflow 65/al c adtech is a 65% Alumina coarsegrained low cement castable designed for aluminiumcontact applications. Suitable for door cills/jambs orwhere impact resistance is required.
technical data
MAXIMUM RECOMMENDED TEMPERATURE 2550F 1400C
BULK DENSITY lb/ft3 Kgs/m3
Cured and then dried at 220F(105C) 168 2690Heated at 1500F(820C) 164 2630
WATER REQUIRED FOR CASTING Approximately5.7%
PERMANENT LINEAR CHANGE ASTM C113 AND C865Heated at 1500F(820C) and then cooled 0.1% ShrHeated at 2500F(1370C) and then cooled 1.1% Exp
MODULUS OF RUPTURE ASTM C133 AND C865 lb/in2 MPaCured and then dried at 220F(105C) 1570 10.8Heated at 1500F(820C) and then cooled 1670 11.5
COLD CRUSHING STRENGTH ASTM C133 AND C865Cured and then dried at 220F(105C) 13870 95.6Heated at 1500F(820C) and then cooled 10760 74.2
NIMROD RATING 40 Impacts
format
loose
dimensions
n/a
37
gre
en
pak 4
5
the a-z of insulation
the
a-z o
f insu
latio
n
Sales Line +44 (0) 1704 226 878
product link
p8 - 21: all ceramic productsp57: anchor systemsp59 - 60: sifca, FIBERstonep61 - 64: bricks
format
25kg boxes
dimensions
n/a
Greenpak 45 is an excellent medium alumina claybonded plastic or moldable with good resistance tothermal shock. Greenpak 45 is a very good generalpurpose plastic.
chemical analysis - calcined basis
Silica SiO2 50.0%Alumina Al2O3 45.8%Iron Oxide Fe2O3 1.5%Lime CaO 0.3%Magnesia MgO 0.3%Titania TiO2 1.3%Alkalis Na2O + K2O 0.8%
technical data
MAXIMUM RECOMMENDED TEMPERATURE 2900F 1600C
QUANTITY REQUIRED Net 144 lb/ft3 2310 Kgs/m3
DRYING AND FIRING SHRINKAGE ASTM C179Expansion or ShrinkageDried at 220F(105C) 0 - 1.0% ShrHeated at 1500F(815C) and then cooled 0 - 1.0% ShrHeated at 2012F(1100C) and then cooled 0 - 1.0% Exp
MODULUS OF RUPTURE ASTM C491 lb/in2 MPaCured and then dried at 220F(105C) 29 - 145 0.2 - 1.0Heated at 1500F(815C) and then cooled 29 - 145 0.2 - 1.0Heated at 2012F(1100C) and then cooled 73 - 218 0.5 - 1.5
COLD CRUSHING STRENGTH ASTM C133 AND C865Cured and then dried at 220F(105C) 217 - 435 1.5 - 3.0
plastics & ramming mixesgreenpak 45
the
a-z
of
insu
lati
on
the a-z of insulation
38
gre
en
pak 8
0
Sales Line +44 (0) 1704 226 878
plastics & ramming mixesgreenpak 80
product link
p8 - 21: all ceramic productsp57: anchor systemsp59 - 60: sifca, FIBERstonep61 - 64: bricks
format
25kg boxes
dimensions
n/a
Greenpak 80 is an 80% alumina plastic or moldablewhich sets hard on drying out.
Greenpak 80 exhibits good resistance to vitrificationand to thermal shock, it f inds application incombustion chambers and burner blocks and manysimilar situations.
chemical analysis - calcined basis
Silica SiO2 13.0%Alumina Al2O3 81.0%Iron Oxide Fe2O3 2.5%Lime CaO 0.3%Magnesia MgO 0.3%Titania TiO2 2.5%Alkalis Na2O + K2O 0.3%
technical data
MAXIMUM RECOMMENDED TEMPERATURE 3000F 1650C
QUANTITY REQUIRED Net 173 lb/ft3 2770 Kgs/m3
DRYING AND FIRING SHRINKAGE ASTM C179Expansion or ShrinkageDried at 220F(105C) 0 - 1.1% ShrHeated at 2550F(1400C) and then cooled 0 - 1.2% ExpHeated at 3000F(1650C) and then cooled 0 - 1.2% Exp
MODULUS OF RUPTURE ASTM C491 lb/in2 MPaCured and then dried at 220F(105C) 250 - 350 1.72 - 2.41Heated at 1500F(815C) and then cooled 150 - 250 1.03 - 1.72Heated at 2550F(1400C) and then cooled 250 - 600 1.72 - 4.14
COLD CRUSHING STRENGTH ASTM C133 AND C865Cured and Then Dried at 220F(105C) 864 - 1440 6 - 10
THERMAL CONDUCTIVITY Btu-in W/mKat a Mean Temperature of ft2 hrF800F(425C) 3.1 0.451200F(650C) 4.1 0.591600F(870C) 5.0 0.722000F(1095C) 5.9 0.85
39
gre
en
pak 8
5p
the a-z of insulation
the
a-z o
f insu
latio
n
Sales Line +44 (0) 1704 226 878
plastics & ramming mixesgreenpak 85p
Greenpak 85P is an 85% alumina chemically bondedplastic or moldable refractory. It possesses goodvolume stability and excellent resistance to slags andalkalis.
Greenpak 85P is used extensively in incinerator liningsand afterburners, aluminum furnace side walls andramps, steel plant maintenance linings, ladle linings foriron, carbon steel, aluminum, brass bronze and zinc. Itis also used in burner blocks and soaking pit linings.
technical data
MAXIMUM RECOMMENDED TEMPERATURE 3100F 1700C
QUANTITY REQUIRED Net 185 lb/ft3 2965 Kgs/m3
DRYING AND FIRING SHRINKAGE ASTM C179Expansion or ShrinkageDried at 220F(105C) 0 - 0.5% ShrHeated at 2550F(1400C) and Then Cooled 0 - 0.7% ShrHeated at 2910F(1600C) and Then Cooled 1.5% Shr - 1.0% Exp
MODULUS OF RUPTURE ASTM C491 lb/in2 MPa Cured and Then Dried at 220F(105C) 580 - 1450 4.0 - 10.0Heated at 1500F(815C) and then cooled 725 - 1450 5.0 - 10.0Heated at 2550F(815C) and then cooled 870 - 1740 6.0 - 12.0
COLD CRUSHING STRENGTH ASTM C133 AND C865Cured and Then Dried at 220F(105C) 3626 - 5076 25.0 - 35.0
THERMAL CONDUCTIVITY Btu-in W/mKat a Mean Temperature of ft2 hrF800F(425C) 14.7 2.121200F(650C) 14.4 2.081600F(870C) 14.1 2.032000F(1095C) 14.5 2.09
chemical analysis - calcined basis
Silica SiO2 10.0%Alumina Al2O3 85.0%Iron Oxide Fe2O3 1.5%Titania TiO2 2.5%Lime CaO 0.2%Magnesia MgO 0.2%Alkalis Na2O + K2O 0.4%
product link
p8 - 21: all ceramic productsp57: anchor systemsp59 - 60: sifca, FIBERstonep61 - 64: bricks
format
25kg boxes
dimensions
n/a
Sales Line +44 (0) 1704 226 878
the
a-z
of
insu
lati
on
the a-z of insulation
40
hyb
on
d
plastics & ramming mixeshybond
product link
p8 - 21: all ceramic productsp57: anchor systemsp59 - 60: sifca, FIBERstonep61 - 64: bricks
format
25kg boxes
dimensions
n/a
chemical analysis - calcined basis
Silica SiO2 53.0%Alumina Al2O3 42.0%Iron Oxide Fe2O3 1.5%Lime CaO 0.4%Magnesia MgO 0.4%Titania TiO2 2.5%Alkalis Na2O + K2O 0.5%
Hybond is a 42% alumina plastic or moldable whichforms a strong bond after drying out.
Hybond is an economic product, recommended for usein applications where severe spalling is encountered. Itis proven in slab and billet heating furnaces, soakingpit covers and walls, rotary heat furnaces and forgefurnaces.
technical data
MAXIMUM RECOMMENDED TEMPERATURE 2550F 1400C
QUANTITY REQUIRED Net 143 lb/ft3 2290 Kgs/m3
DRYING AND FIRING SHRINKAGE ASTM C179Expansion or ShrinkageDried at 220F(105C) 0 - 1.0% ShrHeated at 2550F(1400C) and Then Cooled 0% Shr - 2.0% ExpHeated at 2910F(1600C) and Then Cooled 2 - 4.5% Exp
MODULUS OF RUPTURE ASTM C491 lb/in2 MPa Cured and Then Dried at 220F(105C) 145 - 435 1.0 - 3.0Heated at 1500F(815C) and then cooled 73 - 290 0.5 - 2.0Heated at 2550F(815C) and then cooled 145 - 435 1.0 - 3.0
COLD CRUSHING STRENGTH ASTM C133 AND C865Cured and Then Dried at 220F(105C) 864 - 1296 6 - 9
THERMAL CONDUCTIVITY Btu-in W/mKat a Mean Temperature of ft2 hrF800F(425C) 4.5 0.651200F(650C) 4.9 0.711600F(870C) 5.8 0.842000F(1095C) 7.3 1.05
Sales Line +44 (0) 1704 226 878 41
sup
er g
product link
p8 - 21: all ceramic productsp57: anchor systemsp59 - 60: sifca, FIBERstonep61 - 64: bricks
format
25kg boxes
dimensions
n/a
Super G is a 60% alumina plastic or moldable, whichsets hard on drying out. It has an excellent resistanceto vitrification and resists thermal shock.
Super G is a rugged general purpose product ideal forsoaking pit sidewalls, aluminum furnace upper sidewalls and roofs, reheat furnace sidewalls and roofs,and boilers.
chemical analysis - calcined basis
Silica SiO2 36.0%Alumina Al2O3 60.0%Iron Oxide Fe2O3 1.5%Lime CaO 0.4%Magnesia MgO 0.4%Titania TiO2 2.5%Alkalis Na2O + K2O 0.5%
the a-z of insulation
the
a-z o
f insu
latio
n
technical data
MAXIMUM RECOMMENDED TEMPERATURE 3000F 1650C
QUANTITY REQUIRED Net 150 lb/ft3 2400 Kgs/m3
DRYING AND FIRING SHRINKAGE ASTM C179Expansion or ShrinkageDried at 220F(105C) 0.5 - 1.1% ShrHeated at 2550F(1400C) and Then Cooled 0 - 1.5% ExpHeated at 2910F(1600C) and Then Cooled 1.5 - 4.5% Exp
MODULUS OF RUPTURE ASTM C491 lb/in2 MPa Cured and Then Dried at 220F(105C) 145 - 580 1.0 - 4.0Heated at 1500F(815C) and then cooled 145 - 435 1.0 - 3.0Heated at 2550F(815C) and then cooled 145 - 580 1.0 - 4.0
COLD CRUSHING STRENGTH ASTM C133 AND C865Cured and then dried at 220F(105C) 290 - 508 2.0 - 3.5
THERMAL CONDUCTIVITY Btu-in W/mKat a Mean Temperature of ft2 hrF800F(425C) 4.4 0.631200F(650C) 4.9 0.711600F(870C) 6.0 0.872000F(1095C) 7.3 1.05
plastics & ramming mixessuper g
the
a-z
of
insu
lati
on
the a-z of insulation
42
gre
en
cast
94
Sales Line +44 (0) 1704 226 878
dense castables & gun mixesgreencast 94
product link
p8 - 21: all ceramic productsp57: anchor systemsp59 - 60: sifca, FIBERstonep61 - 64: bricks
format
loose
dimensions
n/a
technical data
MAXIMUM RECOMMENDED TEMPERATURE 3400F 1870C
QUANTITY REQUIRED Net 156 lb/ft3 2500 Kgs/m3
BULK DENSITY lb/ft3 Kgs/m3
Cured and Then Dried at 220F(105C) 159 - 167 2550 - 2680Heated at 1500F(820C) 153 - 159 2450 - 2550
WATER REQUIRED FOR MIXING ApproximatelyPer 100 Kgs 2.1 gal 9.5 Litres
MAXIMUM TIME FROM ADDING WATER TO PLACING MATERIALMinutes 20
PERMANENT LINEAR CHANGE ASTM C113 AND C865Expansion or ShrinkageCured and then dried at 220F(105C) NilHeated at 1500F(820C) and then cooled 0.05 - 0.2% ShrHeated at 2000F(1100C) and then cooled 0 - 0.2% ExpHeated at 2500F(1370C) and then cooled 0.1 - 0.5% ShrHeated at 2900F(1600C) and then cooled 0 - 0.3% ShrHeated at 3300F(1820C) and then cooled 1.0 - 2.0% Shr
MODULUS OF RUPTURE ASTM C133 AND C865 lb/in2 MPaCured and then dried at 220F(105C) 1015 - 1595 7.0 - 11.0Heated at 1500F(820C) and then cooled 870 - 1450 6.0 - 10.0Heated at 2000F(1100C) and then cooled 725 - 1305 5.0 - 9.0Heated at 2500F(1370C) and then cooled 870 - 1450 6.0 - 10.0
COLD CRUSHING STRENGTH ASTM C133 AND C865Cured and then dried at 220F(105C) 5076 - 8410 35.0 - 58.0Heated at 1500F(820C) and then cooled 5076 - 8410 35.0 - 58.0Heated at 2000F(1100C) and then cooled 3625 - 6090 25.0 - 42.0Heated at 2500F(1370C) and then cooled 5076 - 8410 35.0 - 58.0
PARTICLE SIZE ASTM C92Retained on 6 Mesh Tyler Screen Less than 1%
THERMAL CONDUCTIVITY Btu-in W/mKat a Mean Temperature of ft2 hrF400F(205C) 18.3 2.64800F(425C) 15.3 2.211200F(650C) 13.0 1.871600F(870C) 12.5 1.802000F(1095C) 13.1 1.89
Greencast 94 is a dense 94% tabular alumina hydraulicsetting castable, suitable for temperatures up to1870C in oxidising atmospheres. It has highmechanical strength with excellent resistance to impactand abrasion. High chemical purity confers excellentresistance to chemical attack.
chemical analysis - calcined basis
Silica SiO2 TraceAlumina Al2O3 95.0%Iron Oxide Fe2O3 0.1%Lime CaO 4.6%Magnesia MgO 0.2%Alkalis Na2O + K2O 0.3%
typical applications
Petrochemical Industry: Including secondaryreformer linings, fluid catalytic cracking unit, transfer andriser lines, fixed bed hydrocracking unit linings, wasteheat boiler tube sheets in sulphur and ammonia plants,coal gasification ducting.
Metal/Mineral Processing: Including hightemperature cyclones, burner pipe linings, ladles for iron,copper and brass.
43
gre
en
cast 1
55
Sales Line +44 (0) 1704 226 878
the a-z of insulation
the
a-z o
f insu
latio
n
dense castables & gun mixesgreencast 155
product link
p8 - 21: all ceramic productsp57: anchor systemsp59 - 60: sifca, FIBERstonep61 - 64: bricks
format
loose
dimensions
n/a
Greencast 155 is a medium grain size hydraulicbonded, bauxite based refractory, suitable for use to1550C.
Greencast 155 is a rugged refractory suitable forvulnerable areas such as doors, sills and lintels. It findsa range of applications in iron and steel processes,foundries, boilers and non-ferrous plants.
chemical analysis - calcined basis
Silica SiO2 5%Alumina Al2O3 78%Iron Oxide Fe2O3 4.5%
technical data
MAXIMUM RECOMMENDED TEMPERATURE 2820F 1550C
QUANTITY REQUIRED Net 155 lb/ft3 2480 Kgs/m3
BULK DENSITY lb/ft3 Kgs/m3
Cured and then dried at 220F(105C) 153 - 165 2450 - 2650Heated at 1500F(820C) 150 - 159 2400 - 2550
WATER REQUIRED FOR MIXING Approximatelyper 100 Kgs 2.4 gal 10.8 Litres
MAXIMUM TIME FROM ADDING WATER TO PLACING MATERIALMinutes 20
PERMANENT LINEAR CHANGE ASTM C113 AND C865Expansion or ShrinkageCured and then dried at 220F(105C) Less than 0.1% ShrHeated at 1500F(820C) and then cooled 0.2% ShrHeated at 2000F(1100C) and then cooled 0.3% ShrHeated at 2500F(1370C) and then cooled 0.5% Shr
MODULUS OF RUPTURE ASTM C133 AND C865 lb/in2 MPaCured and then dried at 220F(105C) 725 - 1450 5.0 - 10.0Heated at 1500F(820C) and then cooled 435 - 1160 3.0 - 8.0Heated at 2000F(1100C) and then cooled 435 - 1160 3.0 - 8.0Heated at 2500F(1370C) and then cooled 435 - 1160 3.0 - 8.0
COLD CRUSHING STRENGTH ASTM C133 AND C865Cured and then dried at 220F(105C) 3625 - 5946 25.0 - 41.0Heated at 1500F(820C) and then cooled 2175 - 4060 15.0 - 28.0Heated at 2000F(1100C) and then cooled 2175 - 4060 15.0 - 28.0Heated at 2500F(1370C) and then cooled 2175 - 4060 15.0 - 28.0
PARTICLE SIZE ASTM C92Retained on 4 Mesh Tyler Screen (5mm) Less than 10%
THERMAL CONDUCTIVITY Btu-in W/mKat a Mean Temperature of Ft2 hrF400F(204C) 6.9 1.00800F(425C) 7.2 1.041200F(650C 7.2 1.041600F(870C) 7.7 1.112400F(1315C) 8.1 1.17
the
a-z
of
insu
lati
on
the a-z of insulation
44
gre
en
spra
y 1
6
Sales Line +44 (0) 1704 226 878
format
loose
product link
p8 - 21: all ceramic productsp57: anchor systemsp59 - 60: sifca, FIBERstonep61 - 64: bricks
dimensions
n/a
dense castables & gun mixesgreenspray 16
Greenspray 16 is a heat setting maintenance refractoryfor repair of furnace linings by gunning. The materialmay also be installed by hand trowelling. It is suitablefor use on both hot and cold linings.
Greenspray 16 is for repairs to furnace linings, whereproperties similar to that of a plastic or moldable arerequired, as it exhibits similar strength patterns andexcellent resistance to thermal cycling.
technical data
MAXIMUM RECOMMENDED TEMPERATURE 2900F 1600C
QUANTITY REQUIRED Net 128 lb/ft3 2050 Kgs/m3
BULK DENSITY lb/ft3 Kgs/m3
Cured and then dried at 220F(105C) 130 - 135 2080 - 2160Heated at 1500F(820C) 125 - 130 2000 - 2080
PERMANENT LINEAR CHANGE ASTM C113 AND C865Expansion or ShrinkageCured and then dried at 220F(105C) 0 - 0.2% ShrHeated at 1500F(820C) and then cooled 0 - 0.3% ShrHeated at 2000F(1100C) and then cooled 0 - 0.4% ShrHeated at 2500F(1370C) and then cooled 0 - 1.0% ExpHeated at 2800F(1550C) and then cooled 0.5 - 1.5% Shr
MODULUS OF RUPTURE ASTM C133 AND C865 lb/in2 MPaCured and then dried at 220F(105C) 73 - 290 0.5 - 2.0Heated at 1500F(820C) and then cooled 145 - 435 1.0 - 3.0Heated at 2000F(1100C) and then cooled 145 - 580 1.0 - 4.0
COLD CRUSHING STRENGTH ASTM C133 AND C865Cured and then dried at 220F(105C) 1160 - 2900 8.0 - 20.0Heated at 2000F(1100C) and then cooled 1450 - 3625 10.0 - 25.0
PARTICLE SIZE ASTM C92Retained on 6 Mesh Tyler Screen (2.4mm) Less than 10%
chemical analysis - calcined basis
Silica SiO2 48.0%Alumina Al2O3 47.0%Iron Oxide Fe2O3 1.5%Lime CaO 1.0%Magnesia MgO 0.2%Titania TiO2 1.5%Alkalis Na2O + K2O 0.5%
45
hig
h te
mp
era
ture
gu
nn
ing
Sales Line +44 (0) 1704 226 878
the a-z of insulation
the
a-z o
f