STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp.
(Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification,
approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government.
This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.
IES LM-79-08
MEASUREMENT AND TEST REPORT For
Jaykal LED Solutions, Inc 35765 Black Marlin Drive Lewes, Delaware 19958, USA
Test Model: JLS68101-G18IN-1204HO-5C
Report Type:
Electrical and Photometric tests including: Luminous Flux,
Color, Luminous Intensity Distribution, THD, Off-state
Power
Test Engineer: Daniel Duan
Report Number: RSZ140604501-10-M1
Test Date: 2014-06-05 to 2014-06-09
Report Date: 2014-07-15
Reviewed By: Jeanne Han/Safety Manager
Revised Note: This version report “No. RSZ140604501-10-M1” at 2014-07-15 replaced the previous report “No. RSZ140604501-10” at 2014-06-12
Prepared By:
Bay Area Compliance Laboratories Corp. (Shenzhen)
6/F, the 3rd Phase of WanLi Industrial Building,
ShiHua Road, FuTian Free Trade Zone
Shenzhen, Guangdong, China
Tel: +86-755-33320018
Fax: +86-755-33320008
Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial
Area, Tangxia Town, Dongguan, Guangdong, P.R.China.
Accreditation: The NVLAP Lab Code is 200707-0.
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ140604501-10-M1 Page 2 of 13 The NVLAP Lab Code is 200707-0.
1. Product Description
General Information:
Two tubes were received on 2014-06-03 and used for testing. Sample No.: RSZ140604501-S01 and RSZ140604501-S02, Model: JLS68101-G18IN-1204HO-5C . A recessed troffer was used during test as auxiliary equipment detailed as following.
Model Tested: JLS68101-G18IN-1204HO-5C
Manufacturer: Jaykal LED Solutions, Inc
Brand Name: Jaykal
Product Designation: Four-Foot Linear Replacement Lamps
Burning Time Before Test: 0 hour(For New Products)
Auxiliary Equipment: Lithonia 2GT8 lensed recessed troffer
Rated Values:
Rated Voltage/Frequency: 100-277 VAC 50/60Hz
Rated Power: 20W
Nominal CCT: 5000K
2. Standards Used
IESNA LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products
ANSI C82.77-2002: Harmonic Emission Limits – Related Power Quality Requirements for Lighting
3. Description of Test Equipment
Device Manufacture Model No Serial No Test Range Calibration date
Integrating Sphere SENSING SPR-600 S09008 25~50℃ 2014-03-16
Spectral photometer SENSING SPR3000 90902027 350nm~800nm 2014-03-16
Power Meter YOKOGAWA WT-210 91j926132 15/30/60/150/300/60
0 V 2014-03-12
AC Power Supply ALL Power APW-105N 970613 0V-300V 50-400Hz 2014-03-12
Standard Light Source EVERFINE D204 201311 N/A 2013-09-26
Thermal Meter SENSING N/A T-08-EE006-1 25℃ 2014-03-16
DC Power Supply ITECH IT6154 0061 0417
6471 0010 19 0~60V 2014-03-12
AC Power Supply EVERFINE VPS1060 PWM 1101006 0-150V, 0-300V 2014-03-12
DC Power Supply EVERFINE WY12010 1009009 30V/5A 2014-03-12
Power Meter YOKOGAWA WT-210 91KB35700 N/A 2014-03-12
Goniophotometer EVERFINE GO-R5000 YG108492N1
0120001 1600mm,3000W/10A 2014-03-04
Thermal Meter Victor VC230 EE091 0~40℃0~90% 2013-04-01
Standard Light Source EVERFINE D908 1012001 N/A 2014-05-06
Digital Power Meter EVERFINE PF9811 507047 0~35V DC 2013-11-12
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ140604501-10-M1 Page 3 of 13 The NVLAP Lab Code is 200707-0.
Device Manufacture Model No Serial No Test Range Calibration date
AC POWER SUPPLY SZHPC HPA 1103 0003394 3KVA 2014-03-12
Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI).
4. Test Method
Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25°C±1°C during measurement. And relative humidity is less than 65%.
Integrating Sphere System
The system includes AC power source, digital power meter, DC power supply, spectrophotometer, and integrating sphere. The integrating sphere system is calibrated by standard light source before measurement. The system and standard light source has been calibrated regularly and traceable to the National Primary Standards.
4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report.
The uncertainty of the light output (luminous flux) measurements is U=1.64% (K=2), at the 95% confidence level. The
uncertainty of the correlated color temperature measurements is U=21K (K=2), at the 95% confidence level. The
uncertainty of the CRI is U=1.6 (K=2) , at the 95% confidence level.
Goniophotometer System
Two tubes were tested in a recessed troffer.
The goniophotometer system is calibrated by standard light source before measurement. The standard light source has been calibrated regularly and traceable to the National Primary Standards.
Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report.
The uncertainty of the luminous intensity is U=2.82% (K=2) , at the 95% confidence level.
Additional Test
The Additional Test item may not be covered by IESNA LM-79-2008. Additional test including power factor, off-state power and THD, was measured by Digital Power Meter after stabilized at 25°C±1°C.Test voltage for THD and power factor test would be equal to rated voltage or, in case of a voltage range, maximum value of that range.
The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at
the 95% confidence level.
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ140604501-10-M1 Page 4 of 13 The NVLAP Lab Code is 200707-0.
5. Test Result
[Integrating Sphere System]
Total operating time for integrating sphere test: 1.0 hour
Test orientation: Downward
Electrical Measurement
Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor
119.97 60.0 0.1642 19.43 0.986
Photometric Measurement
Luminous Flux (lm) Radiant Flux (W) Efficacy (lm/W) CCT (K) Duv
2864.129 7.528 147.408 4889 5.77E-03
Chromaticity Coordinate
x y u v u' v'
0.3497 0.3670 0.2086 0.3284 0.2086 0.4927
Color Rendering Index
Ra
81.2
R1 R2 R3 R4
78 85 91 82
R5 R6 R7 R8
79 80 87 66
R9 R10 R11 R12
2 65 81 61
R13 R14 R15
80 95 72
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ140604501-10-M1 Page 5 of 13 The NVLAP Lab Code is 200707-0.
Relative Spectral Power Distribution
nm mW
nm mW
nm mW
nm mW
nm mW
380 4.614E-03 465 8.977E-02 550 1.829E-01 635 1.219E-01 720 1.270E-02
385 3.091E-03 470 7.008E-02 555 1.864E-01 640 1.103E-01 725 1.088E-02
390 2.192E-03 475 6.368E-02 560 1.869E-01 645 9.947E-02 730 9.295E-03
395 1.771E-03 480 6.924E-02 565 1.892E-01 650 8.925E-02 735 8.302E-03
400 1.824E-03 485 8.024E-02 570 1.896E-01 655 7.935E-02 740 7.024E-03
405 2.341E-03 490 9.668E-02 575 1.906E-01 660 7.052E-02 745 6.227E-03
410 4.301E-03 495 1.133E-01 580 1.902E-01 665 6.142E-02 750 5.337E-03
415 9.832E-03 500 1.287E-01 585 1.883E-01 670 5.354E-02 755 4.770E-03
420 2.059E-02 505 1.397E-01 590 1.876E-01 675 4.764E-02 760 4.314E-03
425 4.156E-02 510 1.491E-01 595 1.855E-01 680 4.103E-02 765 3.730E-03
430 7.472E-02 515 1.547E-01 600 1.816E-01 685 3.540E-02 770 3.391E-03
435 1.261E-01 520 1.602E-01 605 1.770E-01 690 3.086E-02 775 3.072E-03
440 2.040E-01 525 1.631E-01 610 1.704E-01 695 2.688E-02 780 2.732E-03
445 2.669E-01 530 1.671E-01 615 1.626E-01 700 2.281E-02 785 2.476E-03
450 2.453E-01 535 1.717E-01 620 1.525E-01 705 1.975E-02 790 2.232E-03
455 1.653E-01 540 1.755E-01 625 1.431E-01 710 1.718E-02 795 2.092E-03
460 1.173E-01 545 1.803E-01 630 1.330E-01 715 1.460E-02 800 1.990E-03
0.0
0.2
0.4
0.6
0.8
1.0
1.2
380 440 500 560 620 680 740 800
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ140604501-10-M1 Page 6 of 13 The NVLAP Lab Code is 200707-0.
CIE 1931 x y Chromaticity Diagram
7-Step & 4-Step Chromaticity Quadrangles
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0.30
0.35
0.40
0.45
0.30 0.35 0.40 0.45 0.50
sample
7-STEP 2700K
7-STEP 3000K
7-STEP 3500K
7-STEP 4000K
7-STEP 4500K
7-STEP 5000K
7-STEP 5700K
7-STEP 6500K
4-STEP 2700K
4-STEP 3000K
4-STEP 3500K
4-STEP 4000K
4-STEP 5000K
4-STEP 6500K
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ140604501-10-M1 Page 7 of 13 The NVLAP Lab Code is 200707-0.
[Goniophotometer System]
Total operating time for luminous intensity distribution: 1.0 hour
Test orientation: Downward
Electrical Measurement
Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor
120.1 60.0 0.3312 39.17 0.9850
Photometric Measurement
Luminous Flux (lm) Efficacy (lm/W) CBCP (cd) S/MH (C0/180) S/MH (C90/270)
4586.02 117.08 2039 1.22 1.19
Luminous Intensity Distribution
C0/180 C45/225 C90/270 C135/315 AVG.
Beam Angle (50% Imax): 93.2 92.7 93.7 92.5 93.0
Field Angle (10% Imax): 152.5 145.1 154.7 145.6 149.48
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ140604501-10-M1 Page 8 of 13 The NVLAP Lab Code is 200707-0.
Luminous Intensity (cd) Distribution Data
C
0° 22.5° 45° 67.5° 90° 112.5° 135° 157.5° γ
0.0° 2039 2039 2039 2039 2039 2039 2039 2039
5.0° 2028 2033 2033 2035 2035 2032 2026 2027
10.0° 1992 1992 1990 2007 1999 1997 1995 1994
15.0° 1949 1959 1946 1955 1950 1950 1947 1949
20.0° 1882 1879 1891 1876 1874 1872 1883 1874
25.0° 1793 1791 1777 1770 1758 1768 1779 1778
30.0° 1677 1671 1645 1635 1627 1630 1638 1647
35.0° 1522 1513 1498 1490 1482 1469 1466 1481
40.0° 1340 1329 1317 1318 1312 1282 1270 1280
45.0° 1123 1114 1104 1104 1113 1076 1063 1066
50.0° 881 884 882 872 893 874 863 853
55.0° 673 666 673 667 693 685 665 647
60.0° 507 479 481 496 523 516 498 483
65.0° 378 344 326 369 390 392 357 366
70.0° 286 257 229 290 307 307 258 280
75.0° 215 196 177 227 246 235 195 210
80.0° 152 138 139 161 170 160 145 143
85.0° 76 74 69 72 67 67 65 72
90.0° 0 0 0 0 0 0 0 0
95.0° 0 0 0 0 0 0 0 0
100.0° 0 0 0 0 0 0 0 0
105.0° 0 0 0 0 0 0 0 0
110.0° 1 1 0 0 0 0 1 1
115.0° 1 1 0 0 0 0 1 1
120.0° 1 1 1 1 1 1 1 1
125.0° 0 0 1 1 1 1 2 0
130.0° 0 0 1 1 1 1 2 0
135.0° 0 0 1 1 1 1 1 0
140.0° 0 0 1 1 1 1 1 0
145.0° 0 0 1 1 1 2 1 0
150.0° 0 0 1 1 1 2 1 0
155.0° 1 0 1 1 1 2 1 0
160.0° 1 1 1 1 2 2 1 1
165.0° 1 1 1 2 2 2 1 1
170.0° 1 1 1 2 2 2 1 1
175.0° 1 1 1 2 2 2 1 1
180.0° 1 1 1 2 2 2 1 1
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ140604501-10-M1 Page 9 of 13 The NVLAP Lab Code is 200707-0.
Luminous Intensity (cd) Distribution Data (cont.)
C
180° 202.5° 225° 247.5° 270° 292.5° 315° 337.5° γ
0.0° 2039 2039 2039 2039 2039 2039 2039 2039
5.0° 2025 2026 2022 2026 2031 2028 2027 2032
10.0° 1997 1995 1998 2005 2008 2003 2003 1996
15.0° 1946 1954 1954 1962 1958 1959 1957 1956
20.0° 1879 1879 1885 1880 1881 1880 1887 1886
25.0° 1787 1788 1785 1780 1780 1779 1786 1797
30.0° 1663 1657 1644 1641 1645 1647 1659 1675
35.0° 1504 1484 1474 1472 1490 1492 1502 1518
40.0° 1305 1287 1270 1277 1309 1312 1311 1330
45.0° 1071 1071 1062 1071 1098 1096 1090 1111
50.0° 856 855 865 869 876 861 874 876
55.0° 667 645 663 674 680 658 665 662
60.0° 513 478 483 494 492 475 470 476
65.0° 398 361 342 375 373 357 316 338
70.0° 303 275 244 293 296 282 223 252
75.0° 225 204 186 220 232 218 173 192
80.0° 157 138 133 140 146 143 130 134
85.0° 75 66 46 43 41 46 50 67
90.0° 0 0 0 0 0 0 0 0
95.0° 0 0 0 0 0 0 0 0
100.0° 0 0 0 0 0 0 0 0
105.0° 0 0 0 0 0 0 0 0
110.0° 0 0 0 0 0 0 0 0
115.0° 0 0 0 0 0 0 0 0
120.0° 0 0 0 0 0 0 0 0
125.0° 0 0 0 0 0 0 0 0
130.0° 0 0 0 0 0 0 0 0
135.0° 0 0 0 0 0 0 0 0
140.0° 0 0 0 0 0 0 0 0
145.0° 0 0 0 0 0 0 0 0
150.0° 0 0 0 0 0 0 0 0
155.0° 0 0 0 0 0 0 0 0
160.0° 1 1 0 0 0 0 0 0
165.0° 1 1 1 1 1 1 1 1
170.0° 1 1 1 1 1 1 2 1
175.0° 1 1 1 1 2 2 2 1
180.0° 1 1 1 1 2 2 2 1
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ140604501-10-M1 Page 10 of 13 The NVLAP Lab Code is 200707-0.
Average Area Illumination Figure
Height (m) Diameter
(cm) Eavg(lx) Emax(lx)
0.5 105.4 3431.0 8181.0
1.0 210.8 857.7 2045.0
1.5 316.1 381.2 909.0
2.0 421.5 214.4 511.3
2.5 526.9 137.2 327.3
3.0 632.3 95.3 227.3
3.5 737.7 70.0 167.0
4.0 843.0 53.6 127.8
4.5 948.4 42.4 101.0
5.0 1053.8 34.3 81.8
Angle: 93.0 °. Flux out: 3099.0 lm.
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ140604501-10-M1 Page 11 of 13 The NVLAP Lab Code is 200707-0.
Zonal Lumen Density Measurement
Deg Flux (lm) %
Deg Flux (lm) %
0-5 48.6 1.06 0-5 48.6 1.06
5-10 144.0 3.14 0-10 192.6 4.20
10-15 234.3 5.11 0-15 427.0 9.31
15-20 315.9 6.89 0-20 742.8 16.20
20-25 384.2 8.38 0-25 1127.0 24.58
25-30 434.5 9.47 0-30 1561.6 34.05
30-35 462.8 10.09 0-35 2024.3 44.14
35-40 466.4 10.17 0-40 2490.7 54.31
40-45 443.2 9.66 0-45 2933.9 63.97
45-50 394.9 8.62 0-50 3328.8 72.59
50-55 333.5 7.27 0-55 3662.3 79.86
55-60 265.9 5.80 0-60 3928.3 85.66
60-65 205.2 4.47 0-65 4133.4 90.13
65-70 159.4 3.48 0-70 4292.8 93.61
70-75 125.8 2.74 0-75 4418.6 96.35
75-80 95.4 2.08 0-80 4514.0 98.43
80-85 57.3 1.25 0-85 4571.3 99.68
85-90 12.6 0.27 0-90 4583.8 99.95
90-95 0.0 0.00 0-95 4583.8 99.95
95-100 0.0 0.00 0-100 4583.8 99.95
100-105 0.0 0.00 0-105 4583.9 99.95
105-110 0.1 0.01 0-110 4584.0 99.96
110-115 0.2 0.00 0-115 4584.1 99.96
115-120 0.2 0.00 0-120 4584.3 99.96
120-125 0.2 0.01 0-125 4584.5 99.97
125-130 0.2 0.00 0-130 4584.7 99.97
130-135 0.2 0.00 0-135 4584.8 99.97
135-140 0.2 0.01 0-140 4585.0 99.98
140-145 0.2 0.00 0-145 4585.2 99.98
145-150 0.1 0.00 0-150 4585.3 99.98
150-155 0.1 0.01 0-155 4585.5 99.99
155-160 0.1 0.00 0-160 4585.6 99.99
160-165 0.2 0.00 0-165 4585.8 99.99
165-170 0.1 0.01 0-170 4585.9 100.00
170-175 0.1 0.00 0-175 4586.0 100.00
175-180 0.0 0.00 0-180 4586.0 100.00
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ140604501-10-M1 Page 12 of 13 The NVLAP Lab Code is 200707-0.
[Additional Test]
Test Item Test Voltage (V) Frequency (Hz) Test Result
Power Factor: 277 60 0.9574
Total Harmonic Distortion: 120 60 16.01%
Total Harmonic Distortion: 277 60 14.68%
Off State Power (W): 120 60 0.0
6. Product Photo
JLS68101-G18IN-1204HO-5C
Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian
Free Trade Zone Shenzhen, Guangdong, China
Report No. RSZ140604501-10-M1 Page 13 of 13 The NVLAP Lab Code is 200707-0.
Auxiliary Equipment (Recessed Troffer)
***********END OF REPORT***********