Upload
truongdiep
View
236
Download
13
Embed Size (px)
Citation preview
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 1 of 26 Test Report IEC60950_1F
Test Report issued under the responsibility of:
NCB TÜ V SÜ D PSB Pte Ltd
1 Science Park Drive,
Singapore 118221
TEST REPORT
IEC 60950-1
Information technology equipment – Safety –
Part 1: General requirements
Report Number. .............................. : 081-150833-100
Date of issue ..................................... : 2015-12-03
Total number of pages ...................... 26
Applicant’s name ............................ : PEGATRON Corporation
Address ............................................ : 5F, No.76, Ligong St., Beitou District, 112 Taipei, TAIWAN
Test specification:
Standard ........................................... : IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013
Test procedure ................................. : CB Scheme
Non-standard test method…………..: N/A
Test Report Form No. ..................... : IEC60950_1F
Test Report Form(s) Originator ........ : SGS Fimko Ltd
Master TRF....................................... : Dated 2014-02
Copyright © 2014 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment
and Components (IECEE System). All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory
and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02..
General disclaimer:
The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report.
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 2 of 26 Test Report IEC60950_1F
Test item description ..................... : PC
Trade Mark ...................................... :
Manufacturer .................................. : Same as applicant.
Model/Type reference .................... : Jupiter, JPTxxxxxxxxxxxxxxx ("x" can be any alphanumeric character including blank or "-" or "/" for marketing use only.)
Ratings ............................................ : 19 Vdc, 3.42 A or 4.74 A or 6.32 A
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 3 of 26 Test Report IEC60950_1F
Testing procedure and testing location:
CB Testing Laboratory: TÜ V SÜ D Asia Ltd. Taiwan Branch
Testing location/ address ............................ : 7F., No.37, Sec. 2, Zhongyang S., Rd., Beitou District, Taipei City, 11270, TAIWAN
Associated CB Testing Laboratory: N/A
Testing location/ address ............................ : N/A
Tested by (name + signature) ...................... : Mr. Ralph Lai
Approved by (name + signature) ................. : Mr. Owen Hsu
Testing procedure: TMP/CTF Stage 1: N/A
Testing location/ address ............................ : N/A
Tested by (name + signature) ...................... :
Approved by (name + signature) ................. :
Testing procedure: WMT/CTF Stage 2: N/A
Testing location/ address ............................ : N/A
Tested by (name + signature) ...................... :
Witnessed by (name + signature) ................ :
Approved by (name + signature) ................. :
Testing procedure:
SMT/CTF Stage 3 or 4:
N/A
Testing location/ address ............................ : N/A
Tested by (name + signature) ...................... :
Witnessed by (name + signature) ................ :
Approved by (name + signature) ................. :
Supervised by (name + signature) .............. :
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 4 of 26 Test Report IEC60950_1F
List of Attachments (including a total number of pages in each attachment):
Original Test Report No.:
Attachment No. 1
081-150833-000
National and Group Differences
57
30
pages
pages
+
72
pages attachments
Attachment No. 2 Marking Plate 2 pages
Attachment No. 3 Photo 6 pages
Summary of testing:
Tests performed (name of test and test clause):
All test results were found satisfactory in accordance with IEC 60950-1:2005 (2
nd Edition) +
A1: 2009 + A2:2013 and EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013
Testing location:
All tests as described in Test Case and Measurement Sections were performed at the laboratory described on page 3.
Summary of compliance with National Differences:
List of countries addressed
According to CB Bulletin, the National Differences include Australia (AU), Canada (CA), China (CN),
Germany (DE), Israel (IL), Korea (KR), Switzerland (CH) and United States of America (US). Group
Differences (CENELEC COMMON MODIFICATIONS) as listed in the European Standard are recorded in
this Report.
THE PRODUCT FULFILS THE REQUIREMENTS OF IEC 60950-1:2005 + A1: 2009 + A2:2013 and EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013
Copy of marking plate
The artwork below may be only a draft. The use of certification marks on a product must be
authorized by the respective NCBs that own these marks.
See attachment No. 2 of Test Report Ref. No.: 081-150833-000 and attachment No. 2 of Test Report Ref. No.: 081-150833-100.
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 5 of 26 Test Report IEC60950_1F
Test item particulars ................................................... :
Equipment mobility.................................................: [X] movable [] hand-held [] transportable [] stationary [] for building-in [] direct plug-in
Connection to the mains........................................: [] pluggable equipment [] type A [] type B [] permanent connection [] detachable power supply cord [] non-detachable power supply cord
[X] not directly connected to the mains
Operating condition................................................: [X] continuous [] rated operating / resting time:
Access location ......................................................: [X] operator accessible [] restricted access location
Over voltage category (OVC) ................................: [] OVC I [] OVC II [] OVC III [] OVC IV
[X] other: not directly connected to AC or DC mains.
Mains supply tolerance (%) or absolute mains
supply values .........................................................:
+10 %, -10 %
Tested for IT power systems .................................: [] Yes [X] No
IT testing, phase-phase voltage (V) ......................: 230 V (for Norway)
Class of equipment ................................................: [] Class I [] Class II [X] Class III [] Not classified
Considered current rating of protective device as
part of the building installation (A) .......................:
N/A
Pollution degree (PD) .............................................: [] PD 1 [X] PD 2 [] PD 3
IP protection class ..................................................: Ordinary
Altitude during operation (m) ................................: Up to 2000
Altitude of test laboratory (m) ...............................: below 2000
Mass of equipment (kg) .........................................: Approx. 1.17 (without stand)
Approx. 1.26 (with stand)
Possible test case verdicts:
- test case does not apply to the test object ........... : N/A
- test object does meet the requirement .................. : P (Pass)
- test object does not meet the requirement ........... : F (Fail)
Testing .......................................................................... :
Date of receipt of test item ......................................... : 2015-11-23
Date (s) of performance of tests ............................... : 2015-11-23 to 2015-11-30
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 6 of 26 Test Report IEC60950_1F
General remarks:
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.
Throughout this report a comma / point is used as the decimal separator.
Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided.................................................................:
Yes
Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... :
MAINTEK Computer (Suzhou) Co., Ltd. (ID No.: 51922)
233, Jin Feng Road, Suzhou New District, 215011 Jiangsu, PEOPLE'S REPUBLIC OF CHINA
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 7 of 26 Test Report IEC60950_1F
Report No. < 081-150833-100 >
The modification for this report is to:
1) Replace and evaluate the National and Group Differences for Canada and United Kingdom (listed in Clause 4.3.6 in the European Standard). See attachment No. 1 of Test Report Ref. No.: 081-150833-100 for details.
2) Add alternate motherboard H110-P1, see motherboard difference table and table 1.5.1 for details.
3) Add system rating 19 Vdc, 3.42 A and 19 Vdc, 6.32 A for different CPU rating, see motherboard difference table for details.
4) Add alternate Power Adapter source, see table 1.5.1 for details.
5) Add alternate enclosure construction B, which is similar to original except for front bezel and add openings, see table 4.6.1 & 4.6.2 and attachment photo for details.
6) The equipment provided optional VESA Mount bracket, see attachment photo for details.
7) Test Clause 5.1 Touch current and protective conductor current, due to client request, see Clause 5.1 and Table 5.1 for details.
8) Change model name, from JPTxxxxx to JPTxxxxxxxxxxxxxxx.
For the above described modification the following Testing were considered to be necessary:
S/N Testing Remark/Comments Verdict
1. Clause 1.7 Marking and instructions P
2. Clause 4.2 Mechanical strength P
3. Clause 5.1 Touch current and protective conductor current
(Client request)
N/A
4. Table 1.5.1 List of critical components P
5. Table 1.6.2 Electrical data (in normal conditions) P
6. Table 2.5 Limited power sources P
7. Table 4.5 Thermal requirements P
8. Table 4.6.1 & 4.6.2 Enclosure openings P
9. Table 5.1 Touch current measurement
(Client request)
N/A
10. Table 5.3 Fault condition tests P
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 8 of 26 Test Report IEC60950_1F
General product information:
The equipment is a PC classified as information technology equipment. All models are identical except for model designations.
In models JPTxxxxxxxxxxxxxxx, "x" can be any alphanumeric character including blank or "-" or
"/" for marketing use only.
There are two alternate enclosure construction A or B, which are similar except for front bezel and
add openings, see table 4.6.1 & 4.6.2 and attachment photo for details.
The equipment provided optional VESA Mount bracket, see attachment photo for details. The external adapter is a CB certified device, see appended table 1.5.1 for details. The maximum ambient temperature specified by manufacturer is 40 °C.
There are three system rating and three alternate motherboard Q170-P1, B150-P1 and H110-P1, all
motherboards are similar except for some differences, see below table for the differences:
Motherboard Q170-P1 B150-P1 H110-P1
Rear USB ports USB 3.0*4
USB 3.0*2, USB 2.0*2
USB 3.0*4
System rating 19 Vdc, 6.32 A
or
12 Vdc, 4.74 A
19 Vdc, 6.32 A
or
12 Vdc, 4.74 A
19 Vdc, 3.42 A
or
12 Vdc, 4.74 A
Adapter 90 W 120 W 90 W 120 W 65 W 90 W
CPU 35 W 65 W 35 W 65 W 35 W 65 W
All tests were performed on model Jupiter to represent the other similar models.
Abbreviations used in the report:
- normal conditions N.C. - single fault conditions S.F.C
- functional insulation OP - basic insulation BI
- double insulation DI - supplementary insulation SI - between parts of opposite
polarity BOP - reinforced insulation RI
Indicate used abbreviations (if any)
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 9 of 26 Test Report IEC60950_1F
1.7 Marking and instructions P
1.7.1 Power rating and identification markings See below. P
1.7.1.1 Power rating marking See below. P
Multiple mains supply connections..........................: No connection to the mains. N/A
Rated voltage(s) or voltage range(s) (V) ............... : 19 Vdc. P
Symbol for nature of supply, for d.c. only ............... : P
Rated frequency or rated frequency range (Hz) .... : DC Source. N/A
Rated current (mA or A) ........................................ : 3.42 A or 4.74 A or 6.32 A P
1.7.1.2 Identification markings See marking plate. P
Manufacturer’s name or trade-mark or identification mark ...................................................................... :
Trade-mark: PEGATRON P
Model identification or type reference .................... : Jupiter, JPTxxxxxxxxxxxxxxx ("x" can be any alphanumeric character including blank or "-" or "/" for marketing use only.)
P
Symbol for Class II equipment only ....................... : Class III equipment. N/A
Other markings and symbols ................................ : Additional symbols or markings that do not give rise to misunderstand.
P
1.7.1.3 Use of graphical symbols P
1.7.2 Safety instructions and marking See below for details. P
1.7.2.1 General The safety instruction contains
information for installation,
servicing, transport, storage
and technical data.
No other special installation
instruction required as the
equipment is class III.
P
1.7.2.2 Disconnect devices N/A
1.7.2.3 Overcurrent protective device N/A
1.7.2.4 IT power distribution systems Only SELV inside, no
connection to mains.
N/A
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 10 of 26 Test Report IEC60950_1F
4.2 Mechanical strength P
4.2.10 Wall or ceiling mounted equipment; force (N) .......: The equipment provided optional VESA Mount bracket.
Weight of the equipment: 1.17 kg (without stand) Force applied: 5.1 kg (50 N).
The mounting means withstood the force applied without breaking or damaging the mounting bracket, its securing means, or that portion of the unit to which it was attached.
P
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 11 of 26 Test Report IEC60950_1F
5.1 Touch current and protective conductor current N/A
5.1.1 General Class III equipment.
However, test for accessible
parts due to client request.
(see appended table 5.1).
N/A
5.1.2 Configuration of equipment under test (EUT) N/A
5.1.2.1 Single connection to an a.c. mains supply N/A
5.1.2.2 Redundant multiple connections to an a.c. mains
supply
N/A
5.1.2.3 Simultaneous multiple connections to an a.c. mains
supply
N/A
5.1.3 Test circuit N/A
5.1.4 Application of measuring instrument N/A
5.1.5 Test procedure N/A
5.1.6 Test measurements N/A
Supply voltage (V) ................................................ :
Measured touch current (mA) .............................. :
Max. allowed touch current (mA) .......................... :
Measured protective conductor current (mA) ....... :
Max. allowed protective conductor current (mA) ... :
5.1.7 Equipment with touch current exceeding 3,5 mA N/A
5.1.7.1 General ................................................................. : N/A
5.1.7.2 Simultaneous multiple connections to the supply N/A
5.1.8 Touch currents to telecommunication networks and
cable distribution systems and from
telecommunication networks
N/A
5.1.8.1 Limitation of the touch current to a
telecommunication network or to a cable
distribution system
N/A
Supply voltage (V) ................................................ :
Measured touch current (mA) .............................. :
Max. allowed touch current (mA) .......................... :
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 12 of 26 Test Report IEC60950_1F
1.5.1 TABLE: List of critical components P
Object/part No. Manufacturer/ trademark
Type/model Technical data Standard (Edition / year)
Mark(s) of conformity
1)
Add alternate components:
Power Adapter Chicony Power
Technology Co.,
Ltd.
A15-120P1A I/P:
100-240 Vac,
50-60 Hz, 2.0 A
O/P:
19 Vdc, 6.32 A,
40 C, Class I
IEC 60950-1:
2005+A1+A2
(Additionally
evaluated to EN
60950-1:
2006+A11:
2009+A1:
2010+A12:2011+
A2: 2013)
CB by TUVRh
Chicony Power
Technology Co.,
Ltd.
A15-090P1A I/P:
100-240 Vac,
50-60 Hz, 1.2 A
max.
O/P:
19 Vdc, 4.74 A,
40 C, Class I
IEC 60950-1:
2005+A1+A2
(Additionally
evaluated to EN
60950-1:
2006+A11:
2009+A1:
2010+A12:2011+
A2: 2013)
CB by TUVRh
Chicony Power
Technology Co.,
Ltd.
A11-065N1A I/P:
100-240 Vac,
50-60 Hz, 1.7 A
max.
O/P:
19 Vdc, 3.42 A,
40 C, Class I
IEC 60950-1:
2005+A1+A2
(Additionally
evaluated to EN
60950-1:
2006+A11:
2009+A1:
2010+A12:2011+
A2: 2013)
CB by TUVRh
Delta Electronics,
Inc.
ADP-120RH D,
ADP-120RH B
I/P:
100-240 Vac,
50-60 Hz, 2 A
max.
O/P:
19 Vdc, 6.32 A,
40 C, Class I
IEC 60950-1:
2005+A1+A2
(Additionally
evaluated to EN
60950-1:
2006+A11:
2009+A1:
2010+A12:2011+
A2: 2013)
CB by UL
Delta Electronics,
Inc.
ADP-65JH BB,
ADP-65JH DB,
ADP-65MH B,
ADP-65JH HB,
I/P:
100-240 Vac,
50-60 Hz, 1.5 A
max.
O/P:
19 Vdc, 3.42 A,
40 C, Class I
IEC 60950-1:
2005+A1+A2
(Additionally
evaluated to EN
60950-1:
2006+A11:
2009+A1:
2010+A12:2011+
A2: 2013)
CB by TUVRh
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 13 of 26 Test Report IEC60950_1F
1.5.1 TABLE: List of critical components P
Object/part No. Manufacturer/ trademark
Type/model Technical data Standard (Edition / year)
Mark(s) of conformity
1)
Motherboard -- H110-P1 -- -- --
- RTC Battery Vic Dawn
Enterprise Co Ltd
(KTS)
CR2032 3 Vdc, max.
abnormal
charging current
10 mA
UL 1642 UL
Jhih Hong
Technology Co
Ltd
CR2032 3 Vdc, max.
abnormal
charging current
10 mA
UL 1642 UL
SHUN WO NEW
POWER
BATTERY
TECHNOLOGY
LTD
CR2032 3 Vdc, max.
abnormal
charging current
10 mA
UL 1642 UL
Panasonic
Corporation,
Panasonic
Corporation of
North America
CR2032 3 Vdc, max.
abnormal
charging current
10 mA
UL 1642 UL
Interchangeable CR2032 3 Vdc, maximum
abnormal
charging current
5 mA min.
UL 1642 UL
- PTC
Polyswitch
(M1F3) provided
for Display port,
(M1F1) provided
for HDMI or
Display port,
(VF1) provided
for VGA port use
Littelfuse Inc. 0805L110ULXX
YYYYY (X can
be A-Z, 0-9 or
blank, Y can be
A-Z, 0-9 or
blank)
6 Vdc, 1.1 A EN 60738-1,
EN 60738-1-1,
EN 60730-1
TUVRH
Polytronics
Technology Corp.
SPR-P110 6 Vdc, 1.1 A EN 60738-1,
EN 60738-1-1,
EN 60730-1
TUVRH
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 14 of 26 Test Report IEC60950_1F
1.5.1 TABLE: List of critical components P
Object/part No. Manufacturer/ trademark
Type/model Technical data Standard (Edition / year)
Mark(s) of conformity
1)
- PTC
Polyswitch (UF3,
UF11, UF12,
UF13) provided
for USB ports
use
Littelfuse Inc. 0805L260ULTH
XXYYYY (X can
be A-Z, 0-9 or
blank, Y can be
A-Z, 0-9 or
blank)
6 Vdc, 2.6 A EN 60738-1,
EN 60738-1-1,
EN 60730-1
TUVRH
Polytronics
Technology Corp.
SPR-P260T 6 Vdc, 2.6 A EN 60738-1,
EN 60738-1-1,
EN 60730-1
TUVRH
-PCB Interchangeable Interchangeable V-1 min.,
min. 105 C
UL 796 UL
Supplementary information:
1) Provided evidence ensures the agreed level of compliance. See OD-CB2039.
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 15 of 26 Test Report IEC60950_1F
1.6.2 TABLE: Electrical data (in normal conditions) P
U (Vdc) I (A) Irated (A) P (W) Fuse # Ifuse (A) Condition/status
Motherboard: Q170-P1 (CPU 65W)
Power Adapter: Delta / ADP-120RH D, O/P: 19Vdc, 6.32A
19 4.43 6.32 84.17 -- -- Maximum Normal Load
Motherboard: Q170-P1 (CPU 35W)
Power Adapter: Delta / ADP-90MD H, O/P: 19Vdc, 4.74A
19 4.08 4.74 77.52 -- -- Maximum Normal Load
Motherboard: B150-P1 (CPU 65W)
Power Adapter: Delta / ADP-120RH D, O/P: 19Vdc, 6.32A
19 4.02 6.32 76.38 -- -- Maximum Normal Load
Motherboard: B150-P1 (CPU 35W)
Power Adapter: Delta / ADP-90MD H, O/P: 19Vdc, 4.74A
19 3.54 4.74 67.26 -- -- Maximum Normal Load
Motherboard: H110-P1 (CPU 65W)
Power Adapter: Delta / ADP-90MD H, O/P: 19Vdc, 4.74A
19 3.33 4.74 63.27 -- -- Maximum Normal Load
Motherboard: H110-P1 (CPU 35W)
Power Adapter: Chicony / A11-065N1A, O/P: 19Vdc, 3.42A
19 2.93 3.42 55.67 -- -- Maximum Normal Load
Supplementary information:
Maximum Normal Load:
The unit reads and writes in HDD operating continuously. Each USB port is loaded with 4.5W, run CPU program until performance to 100%. Brightness max.
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 16 of 26 Test Report IEC60950_1F
2.5 TABLE: Limited power sources P
Circuit output tested:
Note: Measured Uoc (V) with all load circuits disconnected:
Components Sample No. Uoc (V) Isc (A) VA
Meas. Limit Meas. Limit
Motherboard: H110-P1
VGA(J69),Pin9 to GND, Normal condition, Protected by VF1
001 5.20Vdc 1.3 ≤8 5.65
(1.3Ax4.35V) ≤100
VGA(J69),Pin1-8,10-17 to GND, Normal condition
001 0Vdc 0 ≤8 0 ≤100
HDMI(J124),Pin 18 to GND, Normal condition, Protected by M1F1
001 5.20Vdc 1.4 ≤8 6.16
(1.4Ax4.40V) ≤100
HDMI(J124),Pin1-17,19 to GND, Normal condition
001 0Vdc 0 ≤8 0 ≤100
DP(J125),Pin 20 to GND, Normal condition, Protected by M1F3
001 3.31Vdc 1.7 ≤8 4.25
(1.7Ax2.50V) ≤100
DP(J125), Pin 1-19 to GND, Normal condition
001 0Vdc 0 ≤8 0 ≤100
SS USB1(J143),Pin1,10 to GND, Normal condition, Protected by UF12
001 5.20Vdc 3.1 ≤8 12.61
(3.1Ax4.07V) ≤100
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 17 of 26 Test Report IEC60950_1F
2.5 TABLE: Limited power sources P
Circuit output tested:
Note: Measured Uoc (V) with all load circuits disconnected:
Components Sample No. Uoc (V) Isc (A) VA
Meas. Limit Meas. Limit
SS USB1(J143),Pin2-9,11-18, to GND, Normal condition
001 0Vdc 0 ≤8 0 ≤100
SS USB1(J139),Pin1,10 to GND, Normal condition, Protected by UF11
001 5.20Vdc 3.2 ≤8 12.28
(3.2Ax3.84V) ≤100
SS USB1(J139),Pin2-9,11-18, to GND, Normal condition
001 0Vdc 0 ≤8 0 ≤100
F SS USB1(J156),Pin1,10 to GND, Normal condition, Protected by UF3
001 5.20Vdc 3.1 ≤8 12.09 (3.1Ax3.90V)
≤100
F SS USB1(J156),Pin2-9,11-18, to GND, Normal condition
001 0Vdc 0 ≤8 0 ≤100
F SS USB1(J151),Pin1,10 to GND, Normal condition, Protected by UF13
001 5.20Vdc 3.2 ≤8 12.12
(3.2Ax3.79V) ≤100
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 18 of 26 Test Report IEC60950_1F
2.5 TABLE: Limited power sources P
Circuit output tested:
Note: Measured Uoc (V) with all load circuits disconnected:
Components Sample No. Uoc (V) Isc (A) VA
Meas. Limit Meas. Limit
F SS USB1(J151), Pin2-9,11-18, to GND, Normal condition
001 0Vdc 0 ≤8 0 ≤100
RJ-45(J8),Pin1-8, to GND, Normal condition
001 0Vdc 0 ≤8 0 ≤100
supplementary information:
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 19 of 26 Test Report IEC60950_1F
4.5 TABLE: Thermal requirements P
Supply voltage (V) .......................... : See beow.
Ambient Tmin (C) ............................ : --
Ambient Tmax (C) ............................ : --
Maximum measured temperature T of part/at: T (C) Allowed
Tmax (C)
Motherboard: Q170-P1 (CPU 65W)
Power Adapter: Delta / ADP-120RH D, O/P: 19Vdc, 6.32A
Enclosure construction B
Test condition: 19 Vdc, Horizontal
19 Vdc, Vertical (with stand)
--
PCB near CPU 75.8 72.2 105
PTC 53.2 47.8 85
RTC 67.3 70.8 100
WiFi card body 71.2 59.1 95
SSD card body 69.0 65.8 95
RAM card body 40.0 40.0 95
Heatsink 67.7 49.2 70
CPU fan 50.9 47.2 70
HDD body 55.5 50.2 70
Enclosure outside (metal) near CPU 52.4 49.4 70
Ambient (Actual ambient before shift)
40.0 (27.9)
40.0 (28.2)
--
Supplementary information:
During test, all opening blocked except rear side openings.
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 20 of 26 Test Report IEC60950_1F
4.5 TABLE: Thermal requirements P
Supply voltage (V) .......................... : See beow.
Ambient Tmin (C) ............................ : --
Ambient Tmax (C) ............................ : --
Maximum measured temperature T of part/at: T (C) Allowed
Tmax (C)
Motherboard: H110-P1 (CPU 65W)
Power Adapter: Delta / ADP-90MD H, O/P: 19Vdc, 4.74A
Enclosure construction B
Test condition: 19 Vdc, Horizontal
19 Vdc, Vertical (with stand)
--
PCB near CPU 64.2 60.8 105
PTC 56.0 53.2 85
RTC 56.9 54.1 100
WiFi card body 62.3 59.7 95
SSD card body 60.4 57.5 95
RAM card body 40.0 40.0 95
Heatsink 62.0 59.3 70
CPU fan module 55.1 52.9 70
HDD body 50.3 48.5 70
Enclosure outside (metal) near CPU 48.1 46.5 70
Ambient (Actual ambient before shift)
40.0 (27.5)
40.0 (28.2)
--
Supplementary information:
During test, all opening blocked except rear side openings.
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 21 of 26 Test Report IEC60950_1F
Temperature T of winding:
t1 (°C) R1 () t2 (°C) R2 () T (C) Allowed
Tmax (C)
Insulation class
-- -- -- -- -- -- -- --
-- -- -- -- -- -- -- --
-- -- -- -- -- -- -- --
Supplementary information:
The temperatures were measured by thermal couple (type K) method under worst case normal mode as described in 1.6.2 at voltage described in 1.4.5. The worst case normal mode is defined with max. load of the equipment.
With max. ambient temperature specified as 40 C, therefore, the maximum temperature rise is calculated as follows:
Components with:
- max. temp. of 105 C (PCB) 105 C
- max. temp. of 100 C (RTC) 100 C
- max. temp. of 100 C (PTC) 85 C
- when no class of insulation is given, min. insulation 105 C assumed.
User accessible area:
- material is plastic 95 C
- material is metal 70 C
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 22 of 26 Test Report IEC60950_1F
4.6.1 &
4.6.2
TABLE: Enclosure openings P
Location Size (mm) Comments
Enclosure construction B, Horizontal, Vertical (with stand)
Top (near DC Fan)
Numerous of slot openings, each measured max. 4.9 mm by 0.9 mm.
No hazardous parts within 5 degrees of projection area.
Left Numerous of slot openings, each measured max. 4.9 mm by 0.9 mm.
No hazardous parts within 5 degrees of projection area.
Right No openings --
Bottom No openings --
Front side Metal part: Several hexagonal openings, each measured max. 6.68 mm in diagonal.
Decoration Part (covered on metal part):
Several slot openings, each measured max. 7.5 mm by 2.6
mm.
No hazardous parts within 5 degrees of projection area.
Rear side (Fan openings)
Several slot openings, each measured max. 4.5 mm by 6.75
mm.
No hazardous parts within 5 degrees of projection area.
Supplementary information:
See attached photos for the details coverage areas of openings.
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 23 of 26 Test Report IEC60950_1F
5.1 TABLE: Touch current measurement N/A
Normal The tests are repeated in
reverse polarity
Test accessible part due to client request:
Power Adapter: FSP / FSP090-DIEBN2
Input voltage: 264 Vac
Input frequency: 60 Hz
Condition Current (mA) L, N output (+) Current (mA) L, N output (+) Comments
System ON 0.16 0.16 Switch “e” opened
Condition Current (mA) L, N plastic enclosure (with foil)
Current (mA) L, N plastic enclosure (with foil)
Comments
System ON 0.01 0.01 Switch “e” closed
Test accessible part due to client request:
Power Adapter: Delta / ADP-90MD H
Input voltage: 264 Vac
Input frequency: 60 Hz
Condition Current (mA) L, N output (+) Current (mA) L, N output (+) Comments
System ON 0.09 0.09 Switch “e” opened
Condition Current (mA) L, N plastic enclosure (with foil)
Current (mA) L, N plastic enclosure (with foil)
Comments
System ON 0.01 0.01 Switch “e” closed
Test accessible part due to client request:
Power Adapter: Chicony / A10-090P3A
Input voltage: 264 Vac
Input frequency: 60 Hz
Condition Current (mA) L, N output (+) Current (mA) L, N output (+) Comments
System ON 0.19 0.19 Switch “e” opened
Condition Current (mA) L, N plastic enclosure (with foil)
Current (mA) L, N plastic enclosure (with foil)
Comments
System ON 0.01 0.01 Switch “e” closed
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 24 of 26 Test Report IEC60950_1F
5.3 TABLE: Fault condition tests P
Ambient temperature (C) ................................... : 25 C, if not specified.
Power source for EUT: Manufacturer, model/type, output rating ......................................................... :
See table 1.5.1 for details.
Component No. Fault Supply voltage (Vdc)
Test time Fuse # Fuse current
(A)
Observation
Motherboard: Q170-P1 (CPU 65W)
Power Adapter: Delta / ADP-120RH D, O/P: 19Vdc, 6.32A
Enclosure construction B
CPU fan Stalled 19 2 h -- -- Unit shutdown, no hazard, no damage. Maximum Temp:
Ambient= 26.9 C
PCB near CPU= 95.0 C
Ventilation openings
Blocked 19 2 h 49 min
-- -- Unit normal operating, no hazard, no damage. Maximum Temp:
Ambient= 26.6 C
PCB near CPU= 84.8 C
Motherboard: H110-P1 (CPU 65W)
Power Adapter: Delta / ADP-90MD H, O/P: 19Vdc, 4.74A
Enclosure construction B
CPU fan Stalled 19 2 h 9 min
-- -- Unit normal operating, no hazard, no damage. Maximum Temp:
Ambient= 28.3 C
PCB near CPU= 87.1 C
Ventilation openings
Blocked 19 1 h 38 min
-- -- Unit normal operating, no hazard, no damage. Maximum Temp:
Ambient= 28.0 C
PCB near CPU= 72.7 C
Motherboard: H110-P1 (CPU 65W)
For RTC battery (RTC battery reverse current test)
RTC battery Normal 19 -- -- -- Measured normal reverse charging current = 0.02 mA
D20 (1-2) s-c 19 -- -- -- Measured abnormal reverse current = 3.18 mA
D20 (2-3) s-c 19 -- -- -- Measured abnormal reverse current = 2.94 mA
R33 s-c 19 -- -- -- Measured abnormal reverse current = 0.02 mA
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 25 of 26 Test Report IEC60950_1F
Component No. Fault Supply voltage (Vdc)
Test time Fuse # Fuse current
(A)
Observation
Motherboard: H110-P1 (CPU 65W)
OVERLOAD OF OPERATOR ACCESSIBLE CONNECTOR TEST (For US deviation)
VGA(J69), Pin9 to GND
o-l 19 1 h -- -- Open circuit voltage = 5.2 Vdc, Maximum available current = 1.9 A. No hazard.
VGA(J69), Pin1-8,10-17 to
GND
o-l 19 -- -- -- Open circuit voltage = 0 Vdc, Maximum available current = 0 A. No hazard.
HDMI(J124), Pin 18 to GND
o-l 19 1 h -- -- Open circuit voltage = 5.2 Vdc, Maximum available current = 1.3 A. No hazard.
HDMI(J124), Pin1-17,19 to
GND
o-l 19 -- -- -- Open circuit voltage = 0 Vdc, Maximum available current = 0 A. No hazard.
DP(J125), Pin 20 to GND
o-l 19 1 h -- -- Open circuit voltage = 3.31 Vdc, Maximum available current = 1.6 A. No hazard.
DP(J125), Pin 1-19 to GND
o-l 19 -- -- -- Open circuit voltage = 0 Vdc, Maximum available current = 0 A. No hazard.
SS USB1(J143),
Pin1,10 to GND
o-l 19 1 h -- -- Open circuit voltage = 5.2 Vdc, Maximum available current = 3.0 A. No hazard.
SS USB1(J143),
Pin2-9,11-18, to GND
o-l 19 -- -- -- Open circuit voltage = 0 Vdc, Maximum available current = 0 A. No hazard.
SS USB1(J139),
Pin1,10 to GND
o-l 19 1 h -- -- Open circuit voltage = 5.2 Vdc, Maximum available current = 3.1 A. No hazard.
SS USB1(J139), Pin2-9,11-18
o-l 19 -- -- -- Open circuit voltage = 0 Vdc, Maximum available current = 0 A. No hazard.
F SS USB1(J156),
Pin1,10 to GND
o-l 19 1 h -- -- Open circuit voltage = 5.2 Vdc, Maximum available current = 3.0 A. No hazard.
F SS USB1(J156),
Pin2-9,11-18, to GND
o-l 19 -- -- -- Open circuit voltage = 0 Vdc, Maximum available current = 0 A. No hazard.
TÜ V SÜ D Asia Ltd. Taiwan Branch Report reference No.: 081-150833-100
7F., No. 37, Sec. 2, Zhongyang S. Rd., JPTxxxxxxxxxxxxxxx-M1.DOC
Beitou District, Taipei City, 11270, Taiwan Page 26 of 26 Test Report IEC60950_1F
Component No. Fault Supply voltage (Vdc)
Test time Fuse # Fuse current
(A)
Observation
F SS USB1(J151),
Pin1,10 to GND
o-l 19 1 h -- -- Open circuit voltage = 5.2 Vdc, Maximum available current = 3.1 A. No hazard.
F SS USB1(J151),
Pin2-9,11-18, to GND
o-l 19 -- -- -- Open circuit voltage = 0 Vdc, Maximum available current = 0 A. No hazard.
RJ45 (J8), Pin1-8 to GND
o-l 19 -- -- -- Open circuit voltage = 0 Vdc, Maximum available current = 0 A. No hazard.
Supplementary information:
Fault: s-c = short circuit; o-l = overload