1
H H y y d d r r o o C C / / M M E E G G MEG Sensor Mono Ethylene Glycol is one of the most important fluids in the modern Oil + Gas industry. Indeed, in many areas of the offshore, the monitoring of MEG has become a necessity. CONTROS’ HydroC™ / MEG is a unique underwater leakage sensor solving the global problems of the in-situ measurements of Mono Ethylene Glycol. Applications include offshore pipeline inspections, leakage detection, water & waste water treatment tasks and risk management solutions. HydroC™ / MEG - Sensor for Mono Ethylene Glycol (Anti-freeze) in water Function principle MEG diffuses out of the liquid through a special silicone membrane (patented) into the detector chamber. Inside the chamber MEG gas is measured electronically with an adaptive analysing system and converts into the output signals. Patent pending. Membrane Standard: 10 μm silicone membrane. Other options or anti fouling device on request Operational depth 2000 m, 4000m, 6000m Temperature -5°C… +50 °C, other ranges on request Measuring range 0…100% MEG, other ranges on request Resolution 0.1 % Accuracy ±3% reading + 1.5% full scale range (one year max.) Response time typ. 20 seconds, T90 time typ. 45 seconds Zero adjust Offset zeroing offline with software ADC 24 Bit AD Converter with DSP Controller Power supply Wide range 10 .. 30 VDC typ. 250 mA @ 12V (max. 3,5 W) Connector Connector SUBCONN ® MCBH8MTI 8-pin Analogue Output 0 ... 5 V sensor reading Digital Output RS-232C, RS-485, CONTROS Long-Range-Modem up to 25 km Housing 90 d x 380 mm Titanium, other on request (1.4571, POM) Weight 3.8 kg / 1.8 kg approx. in air / water Memory, Datalogger Option internal SmartDI Datalogger with 2 GB CompactFlash Memory RS-232, RS-495 Output Binary and ASCII / NMEA-0183 Format Spider ROV on pipeline survey © Statoil/Norsk Hydro KP30.244 Raw data voltage signal for MEG (MEG exposure 14:28:00 to 14:46:00) 2.35 2.4 2.45 2.5 2.55 2.6 2.65 2.7 14:00:00 14:02:00 14:04:00 14:06:00 14:08:00 14:10:04 14:12:00 14:14:40 14:16:40 14:18:40 14:20:40 14:23:09 14:25:00 14:27:00 14:29:00 14:31:00 14:33:00 14:35:01 14:37:20 14:39:20 14:41:20 14:43:20 14:46:20 14:48:20 14:50:20 14:52:20 14:54:20 14:56:20 14:58:20 Time/UTC V Raw MEG voltage Signal of a Mono Ethylene Glycol umbilical leakage in seawater at 36 PSU, +8°C, 142m detected with a work ROV. Symphotic TII Corporation 880 Calle Plano, Unit K Camarillo, CA 93012 Tel: 805-484-6639 www.symphotic.com Roper Resources Ltd. 984 St. Patrick Street Victoria, BC V8S 4X5 Tel: 805-798-0277 www.roperresources.com © CONTROS Systems & Solutions GmbH 2007. All rights reserved. In view of our policy of continual improvement, the design and specifications of our products may vary from those illustrated in this brochure. All pictures and trademarks mentioned in this user manual are property of their respective owners. HydroC is the trademark of CONTROS Systems & Solutions GmbH in Germany. SmartDI and CONTROS are the applied trademarks of CONTROS Systems & Solutions GmbH. 15.06.2007

HydroC-MEG_ENG

Embed Size (px)

DESCRIPTION

HydroC™ / MEG - Sensor for Mono Ethylene Glycol (Anti-freeze) in water Signal of a Mono Ethylene Glycol umbilical leakage in seawater at 36 PSU, +8°C, 142m detected with a work ROV. V Raw MEG voltage Spider ROV on pipeline survey © Statoil/Norsk Hydro KP30.244 Raw data voltage signal for MEG (MEG exposure 14:28:00 to 14:46:00) 2.35 2.45 2.55 2.65 2.4 2.5 2.6 2.7

Citation preview

Page 1: HydroC-MEG_ENG

HHyyddrrooCC™™// MMEEGG MMEEGG SSeennssoorr

Mono Ethylene Glycol is one of the most important fluids in the modern Oil + Gas industry. Indeed, in many areas of the offshore, the monitoring of MEG has become a necessity. CONTROS’ HydroC™ / MEG is a unique underwater leakage sensor solving the global problems of the in-situ measurements of Mono Ethylene Glycol. Applications include offshore pipeline inspections, leakage detection, water & waste water treatment tasks and risk management solutions. HydroC™ / MEG - Sensor for Mono Ethylene Glycol (Anti-freeze) in water

Function principle MEG diffuses out of the liquid through a special silicone membrane (patented) into the detector chamber. Inside the chamber MEG gas is measured electronically with an adaptive analysing system and converts into the output signals. Patent pending.

Membrane Standard: 10 µm silicone membrane. Other options or anti fouling device on request Operational depth 2000 m, 4000m, 6000m

Temperature -5°C… +50 °C, other ranges on request Measuring range 0…100% MEG, other ranges on request Resolution 0.1 %

Accuracy ±3% reading + 1.5% full scale range (one year max.) Response time typ. 20 seconds, T90 time typ. 45 seconds

Zero adjust Offset zeroing offline with software

ADC 24 Bit AD Converter with DSP Controller Power supply Wide range 10 .. 30 VDC

typ. 250 mA @ 12V (max. 3,5 W) Connector Connector SUBCONN® MCBH8MTI 8-pin Analogue Output 0 ... 5 V sensor reading Digital Output RS-232C, RS-485, CONTROS Long-Range-Modem up to 25 km Housing 90 d x 380 mm Titanium, other on request (1.4571, POM) Weight 3.8 kg / 1.8 kg approx. in air / water Memory, Datalogger

Option internal SmartDI Datalogger with 2 GB CompactFlash Memory RS-232, RS-495 Output Binary and ASCII / NMEA-0183 Format

Spider ROV on pipeline survey © Statoil/Norsk

Hydro

KP30.244 Raw data voltage signal for MEG (MEG exposure 14:28:00 to 14:46:00)

2.35

2.4

2.45

2.5

2.55

2.6

2.65

2.7

14:0

0:00

14:0

2:00

14:0

4:00

14:0

6:00

14:0

8:00

14:1

0:04

14:1

2:00

14:1

4:40

14:1

6:40

14:1

8:40

14:2

0:40

14:2

3:09

14:2

5:00

14:2

7:00

14:2

9:00

14:3

1:00

14:3

3:00

14:3

5:01

14:3

7:20

14:3

9:20

14:4

1:20

14:4

3:20

14:4

6:20

14:4

8:20

14:5

0:20

14:5

2:20

14:5

4:20

14:5

6:20

14:5

8:20

Time/UTC

V Raw MEG voltage

Signal of a Mono Ethylene Glycol umbilical leakage in seawater at 36 PSU, +8°C, 142m detected with a work ROV.

Symphotic TII Corporation 880 Calle Plano, Unit K Camarillo, CA 93012 Tel: 805-484-6639 www.symphotic.com

Roper Resources Ltd. 984 St. Patrick Street Victoria, BC V8S 4X5 Tel: 805-798-0277 www.roperresources.com

© CONTROS Systems & Solutions GmbH 2007. All rights reserved. In view of our policy of continual improvement, the design and specifications of our products may vary from those illustrated in this brochure. All pictures and trademarks mentioned in this user manual are property of their respective owners. HydroC is the trademark of CONTROS Systems & Solutions GmbH in Germany. SmartDI and CONTROS are the applied trademarks of CONTROS Systems & Solutions GmbH. 15.06.2007