© 2010 IBM Corporation

The IBM POWER7 HUB Module:A Terabyte Interconnect Switch forHigh- Performance Computer Systems

Hot Chips 22

Baba Arimilli: Chief Architect

Steve Baumgartner: Senior Design Engineer

Scott Clark, Dan Dreps, Dave Siljenberg & Andrew Maki

Page 2: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation2 8/26/2010

Outline

PERCS Overview– HPCS Program Background– Design Point – Hierarchical Structure and Interconnect

POWER7 Hub Chip– Overview– Key Functional Units– Chip Floorplan / Metrics– Summary

POWER7 Hub Module and Off -chip Interconnect– Summary of I/Os and PLL’s– 10Gb/s Physical Transport Circuit Architectures– Hardware Characterization– Summary

This material is based upon work supported by the Defense Advanced Research Projects Agency under its Agreement No. HR0011-07-9-0002.

Any opinions, findings and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the Defense Advanced Research Projects Agency.

“This design represents a tremendous increase in the use of optics in systems, and a disruptive transition from datacom- to computercom-style optical interconnect technologies.”

Page 3: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation3 8/26/2010

DARPA’s “High Productivity Computing Systems” Program

Impact :– Performance (time-to-solution): speedup by 10X to 40X– Programmability (idea-to-first-solution): dramatically reduce cost & development time – Portability (transparency): insulate software from system– Robustness (reliability): continue operating in the presence of localized hardware

failure, contain the impact of software defects, & minimize likelihood of operator error

Applications :

Ocean/wave Forecasting

Weather Prediction Ship DesignClimate

ModelingNuclear Stockpile

StewardshipWeapons

Integration

Goal: Provide a new generation of economically viable high p roductivity computing systems for the national security and ind ustrial user community

PERCS – Productive, Easy- to-use, Reliable Computing System is IBM’s response to DARPA’s HPCS Program

Page 4: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation4 8/26/2010

High-level Requirements and Design Point

High Bisection Bandwidth– Hub chip with high fan-out

Low Latency– Two-Level Direct Connect Topology for Interconnect

High Interconnect Bandwidth (even for packets < 50 bytes)– Architect switch pipeline to handle small packets– Automatically (in hardware) aggregate and disaggregate small packets

Page 5: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation5 8/26/2010

PERCS POWER7 Hierarchical Structure

POWER7 Chip– 8 Cores

POWER7 QCM & Hub Chips – QCM: 4 POWER7 Chips

•32 Core SMP Image– Hub Chip: One per QCM

•Interconnect QCM, Nodes, and Super Nodes– Hub Module: Hub Chip with Optics

POWER7 HPC Node– 2U Node – 8 QCMs, 8 Hub Chip Modules

•256 Cores

POWER7 ‘Super Node’ – Multiple Nodes per ‘Super Node’– Basic building block

Full System – Multiple ‘Super Nodes’

HubChip

Hub Modulewith Optics

Page 6: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation6 8/26/2010

Logical View of PERCS Interconnect

Supernode

Drawer

Quad POWER7 moduleHub chip

ISR(Integrated

Switch/Router)

PO

WE

R7

Coh

eren

cy B

us

POWER7chip

POWER7chip

POWER7 chip

POWER7chip

1

8

1

n

1

N.

..

full directconnectivity

betweenQuad Modules

via L -links

“local” L -links within Drawers

“remote” L -linksbetween Drawers

D-links

Full directConnectivity

between Supernodesvia D-links

. . .

7

24

16

1

1

1

Sm

pRou

ter

HFI(Host Fabric

Interface)

HFI(Host Fabric

Interface )

CAU(Collective

Acceleration Unit

...

Page 7: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation7 8/26/2010

POWER7 Hub Chip

Page 8: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation8 8/26/2010

POWER7 Hub Chip Overview

Extends POWER7 capability for high performance cluster optimized systems

Replaces external switching and routing functions in prior networks

Low diameter Two-tier Direct graph network topology is used to interconnect tens of thousands of POWER7 8-core processor chips to dramatically improve bi-section bandwidth and latency

Highly Integrated Design– Integrated Switch/Router (ISR)– Integrated HCA (HFI)– Integrated MMU (NMMU)– Integrated PCIe channel controllers– Distributed function across the POWER7 and Hub chipset– Chip and optical interconnect on module

• Enables maximum packaging density

Hardware Acceleration of key functions– Collective Acceleration

•No CPU overhead at each intermediate stage of the spanning tree– Global Shared Memory

•No CPU overhead for remote atomic updates•No CPU overhead at each intermediate stage for small packet disaggregation/aggregation

– Virtual RDMA•No CPU overhead for address translation

P7 P7 P7 P7

Coherency Bus Ctl

HFI

Hub

HFI

Hub

Integrated Switch Router

CAU

Page 9: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation9 8/26/2010

POWER7 Hub Chip Block Diagram

POWER7 Coherency Bus

HFI HFINMMU

CAU

POWER7 LinkCtl

ISR

LR LinkCtl D LinkCtl

LL L

inkC

tl PCIE 2.1

x16

PCIE 2.1

x16

PCIE 2.1

x8

24x 16x

24x 16x

24 LRemote – 10 Gb/s x 6b 16 D – 10 Gb/s x 12b

7 LL

ocal

–3

Gb/

s x

8B

4 POWER7 Links – 3 Gb/s x 8B

3 PC

IE –

5 Gb/s x 40b

Inte

r-N

ode

Con

nect

Intra -SuperNode Connect Inter -SuperNode Connect

POWER7 QCM Connect

PC

IE C

onnect

192 GB/s

40 GB/s

336 GB/s

240 GB/s 320 GB/s

1.128 TB/s of off-chip interconnect bandwidth

Page 10: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation10 8/26/2010

POWER7 Link

ISR

POWER7 Coherency Bus

End-to-End Packet Flow

Proc,caches

POWER7 Link

...POWER7

Chip

HubChip

ISR Network

Proc,caches

POWER7 Coherency Bus

Mem

HFI

ISR

ISR ISR

.

.

HFI

POWER7 Chip

HubChip

Proc,caches ... Proc,

caches Mem

POWER7 Coherency Bus

POWER7 Coherency Bus

HFI HFI

Page 11: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation11 8/26/2010

Host Fabric Interface (HFI) Features

Non-coherent interface between the POWER7 QCM and the ISR

– Four ramps/ports from each HFI to the ISR

Communication controlled through “windows”– Multiple supported per HFI

Address Translation provided by NMMU– HFI provides EA, LPID, Key, Protection Domain– Multiple page sizes supported

POWER7 Cache-based sourcing to HFI, injection from HFI

– HFI can extract produced data directly from processor cache

– HFI can inject incoming data directly into processor L3 cache

POWER7 Coherency Bus

HFI HFI

NMMU

CAU

POWER7 LinkCtl

ISR

LR LinkCtl D LinkCtl

LL L

inkC

tl PCIE 2.1

x16

PCIE 2.1

x16

PCIE 2.1

x8

24x 16x

24x 16x

Page 12: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation12 8/26/2010

Host Fabric Interface (HFI) Features (cont’d)

Supports three APIs– Message Passing Interface (MPI)– Global Shared Memory (GSM)

• Support for active messaging in HFI (and POWER7 Memory Controller)– Internet Protocol (IP)

Supports five primary packet formats– Immediate Send

• ICSWX instruction for low latency– FIFO Send/Receive

• One to sixteen cache lines moved from local send FIFO to remote receive FIFO– IP

• IP to/from FIFO• IP with Scatter/Gather Descriptors

– GSM/RDMA• Hardware and software reliability modes

– Collective: Reduce, Multi-cast, Acknowledge, Retransmit

Page 13: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation13 8/26/2010

Host Fabric Interface (HFI) Features (cont’d)

GSM/RDMA Packet Formats– Full RDMA (memory to memory)

• Write, Read, Fence, Completion• Large message sizes with multiple packets per message

– Half-RDMA (memory to/from receive/send FIFO)• Write, Read, Completion• Single packet per message

– Small-RDMA (FIFO to memory) • Atomic updates• ADD, AND, OR, XOR, and Cmp & Swap with and without Data Fetch

– Remote Atomic Update (FIFO to memory)• Multiple independent remote atomic updates • ADD, AND, OR, XOR• Hardware guaranteed reliability mode

Page 14: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation14 8/26/2010

Integrated Switch Router (ISR) Features

Two tier, full graph network

3.0 GHz internal 56x56 crossbar switch– 8 HFI, 7 LL, 24 LR, 16 D, and SRV ports

Virtual channels for deadlock prevention

Input/Output Buffering

2 KB maximum packet size– 128B FLIT size

Link Reliability– CRC based link-level retry– Lane steering for failed links

IP Multicast Support– Multicast route tables per ISR for replicating and forwarding multicast packets

Global Counter Support– ISR compensates for link latencies as counter information is propagated – HW synchronization with Network Management setup and maintenance

POWER7 Coherency Bus

HFI HFI

NMMU

CAU

POWER7 LinkCtl

ISR

LR LinkCtl D LinkCtl

LL L

inkC

tl PCIE 2.1

x16

PCIE 2.1

x16

PCIE 2.1

x8

24x 16x

24x 16x

Page 15: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation15 8/26/2010

Integrated Switch Router (ISR) - Routing

Routing Characteristics– 3-hop L-D-L longest direct route– 5-hop L-D-L-D-L longest indirect route– Cut-through Wormhole routing– Full hardware routing using distributed route tables across the ISRs

• Source route tables for packets injected by the HFI• Port route tables for packets at each hop in the network• Separate tables for inter-supernode and intra-supernode routes

– FLITs of a packet arrive in order, packets of a message can arrive out of order

Routing Modes– Hardware Single Direct Routing– Hardware Multiple Direct Routing

• For less than full-up system where more than one direct path exists– Hardware Indirect Routing for data striping and failover

• Round-Robin, Random– Software controlled indirect routing through hardware route tables

Page 16: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation16 8/26/2010

SuperNode

QCM: 4 chip POWER7 processor module

7 Llocal Links to Hubs within the drawer

POWER7 IH Drawer with 8 octants (QCM-Hub chip pairs)

Hub chip withIntegrated Switch Router (ISR)

ISR

24 Lremote Links to Hubs in other three drawers of the supernode

16 D links to other supernodes

Page 17: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation17 8/26/2010

SN-SN Direct Routing

SuperNode A

Direct RoutingSuperNode B

L-Hops: 2D-Hops: 1

- Max Bisection BW- One to many paths depending on system size

Total: 3 hops

D3

LR12

LR21

Page 18: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation18 8/26/2010

SN-SN Indirect Routing

SuperNode A SuperNode B

SuperNode x

L-Hops: 3D-Hops: 2

Indirect Routing

Total: 5 hops

D5

D12

LR21

LL7

LR30

Total paths = # SNs – 2

Page 19: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation19 8/26/2010

Collectives Acceleration Unit (CAU) Features

Operations– Reduce: NOP, SUM, MIN, MAX, OR, AND, XOR– Multicast

Operand Sizes and Formats– Single Precision and Double Precision – Signed and Unsigned– Fixed Point and Floating Point

Extended Coverage with Software Aid– Types: barrier, all-reduce– Reduce ops: MIN_LOC, MAX_LOC, (floating point) PROD

Tree Topology– Multiple entry CAM per CAU: supports multiple independent trees– Multiple neighbors per CAU: each neighbor can be either a local or remote CAU/HFI– Each tree has one and only one participating HFI window on any involved node– It’s up to the software to setup the topology

POWER7 Coherency Bus

HFI HFI

NMMU

CAU

POWER7 LinkCtl

ISR

LR LinkCtl D LinkCtl

LL L

inkC

tl PCIE 2.1

x16

PCIE 2.1

x16

PCIE 2.1

x8

24x 16x

24x 16x

Page 20: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation20 8/26/2010

Collectives Acceleration Unit (CAU) Features (cont’d)

Sequence Numbers for Reliability and Pipelining– Software driven retransmission protocol if credit return is delayed– The previous collective is saved on CAU for retransmission

• Allows retransmit from point of failure vs. restart of entire operation

Reproducibility – Binary trees for reproducibility– Wider trees for better performance

Page 21: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation21 8/26/2010

POWER7 Hub Chip

45 nm lithography, Cu, SOI– 13 levels metal– 440M transistors

582 mm2

– 26.7 mm x 21.8 mm– 3707 signal I/O– 11,328 total I/O

61 mm x 96 mm Glass Ceramic LGA module– 56 – 12X optical modules

• LGA attach onto substrate

1.128 TB/s interconnect bandwidth

D LinkPhys

LR & DLinkPhys

ISR

HFI HFINMMU

PCIE PCIE PCIE

PCIE Phys

CAU

LLocal Link Phys

POWER7 Coherency Bus

PO

WE

R7

Coh

eren

cy B

us

POWER7 Phys

PO

WE

R7

Phy

s

Page 22: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation22 8/26/2010

Key System Benefits Enabled by the POWER7 Hub Chip

A PetaScale System with Global Shared Memory

Dramatic improvement in Performance and Sustained Performance– Scale Out Application Performance (Sockets, MPI, GSM)– Ultra-low latency, enormous bandwidth and very low CPU utilization

Elimination of the Traditional Infrastructure– HPC Network: No HCAs and External Switches, 50% less PHYs and cables of equivalent fat-tree

structure with the same bisection bandwidth– Storage: No FCS HBAs, External Switches, Storage Controllers, DASD within the compute node– I/O: No External PCI-Express Controllers

Dramatic cost reduction– Reduce the overall Bill of Material (BOM) costs in the System

A step function improvement in Data Center reliability– Compared to commodity clusters with external storage controllers, routers/switches, etc.

Full virtualization of all hardware in the data center

Robust end -to-end systems management

Dramatic reduction in Data Center power compared to commodity clusters

Page 23: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation23 8/26/2010

Outline

Background, Goals, and Design Point– HPCS Program Background– Design Point and Topology– Hierarchical Structure and Interconnect

POWER7 Hub Chip– Design Overview– Key Functional Units– Chip Floorplan / Metrics– Summary

POWER7 Hub Module and Off -chip Interconnect– Summary of I/Os and PLL’s– 10Gb/s Physical Transport Circuit Architectures– Hardware Characterization– Summary

This material is based upon work supported by the Defense Advanced Research Projects Agency under its Agreement No. HR0011-07-9-0002.

Any opinions, findings and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the Defense Advanced Research Projects Agency.

“This design represents a tremendous increase in the use of optics in systems, and a disruptive transition from datacom- to computercom-style optical interconnect technologies.”

Page 24: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation24 8/26/2010

Off-chip Interconnect and PLL’s (4) 8B W,X,Y,Z Interconnect Bus to POWER7

– 3.0 Gb/s Single Ended EI-3 → 192 GB/s throughput

(7) 8B L-Local (LL) Interconnect Busses to Hub chips– 3.0 Gb/s Single Ended EI-3 → 336 GB/s throughput

• Shared physical transport for Cluster Interconnect andPOWER7 Coherency Bus protocol

(24) L-Remote: LR[0..23] within Drawer Hub Optical Interconnect Bus– 6b @ 10Gb/s Differential, 8/10 encoded → 240GB/s throughput

(16) D[0..15] between Drawer Hub Optical Interconnect Bus– 10b @ 10Gb/s Differential 8/10 encoded → 320 GB/s throughput

PCI General Purpose I/O → 40GB/s throughput

24 total PLL’s – (3) “Core” PLLs

• (1) Internal Logic • (1) W,X,Y,Z EI3 buses • (1) LL0 – LL6 EI3 buses– (2) ”Intermediate Frequency “IF LC Tank” PLLs

• (1) Optical LR buses • (1) Optical D buses– (14) High Frequency “HF LC Tank” PLLs

• (6) Optical LR buses • (8) Optical D buses– (5) PCI-E “Combo PHY” PLLs

1.128 TB/s Total Hub I/O

Bandwidth

Page 25: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation25 8/26/2010

µLGA Interposer

Optical Modules & Fiber Ribbons

Hub Module Overview

Power7Hub Chip

D-link Optical

Module Sites

LR-link Optical Module Sites

Module Assembly

Attribute Definition

Technology High Performance Glass Ceramic LGA

Body Size 61mm x 95.5mm

LGA Grid Depopulated 58 x 89

Layer Count 90

Module BSM I/O 5139

Page 26: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation26 8/26/2010

10Gb/s D-link & LR-link PHY floorplan 24 TX and 24 RX core sharing 1 HF PLL

VDD

GND

VIO

Signals

Rx Digital

Custom

Clocks

PLL

Tx Digital

FIFO Cntl

Level Trans

iodc_m

inikerf_m

ac

impcntl

Control

Clock

Dist

TX

Com

mon

Digital

Clock

Dist

RX

Digital

impcntl

PLL

SCAN Only

RX

Analog

Dividers, E

/W B

ufs&

jitgenN

/SB

ufsN

/SB

ufs

Analog test points (ana_snif <0:1>)

iref

iref

iref

iref

iref

iref

p n

avdd

agndB

GR

HFclk+/-

Term Cal pins – cal_imped <0:1>

2GH

z PLL clk

(fsb) n p

Power clampPower clamp

Power clampPower clamp

Power clampPower clamp

Power clampPower clamp

TX

Analog

fifoctrl

Page 27: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation27 8/26/2010

10Gb/s D-link & LR-link PHY Transmitter Complex Features

10-to-1 serialization at 10.0 Gb/s.

Driver Impedance calibration– Calibration at power-on determines the part specific number of SST driver segments to

enable to achieve the desired source impedance

On-chip T-coils are used for improved return loss

Precursor / Post Cursor FFE levels with amplitude margining– 6 dB post cursor FFE & 3 dB precursor FFE capability– 6 dB margining capability

FFE2 / FFE3 modes available– FFE2 mode has lower latency vs. FFE3

Manufacturing test modes– Flush DC data to the c4 pads, boundary scan receiver & latches.– Provide clock to RX for test mode.– Individual SST segment test for fault coverage– On-die wrap test enabling at speed Built In Self Test

Global Configuration Ring (GCR) support for transmitter configuration and impedance calibrator sensing

Page 28: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation28 8/26/2010

10Gb/s D-link & LR-link PHY Transmitter Block Diagram TX Output Performance

– DCD < 3% UI– Tj < 17% UI

3.2 mW / Gb

Page 29: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation29 8/26/2010

10Gb/s D-link & LR-link PHY Receiver Complex Features

1-to-10 deserialization at 10.0 Gb/s

CML Peaking Preamp, per lane offset calibration– Calibration performed at power-on to compensate for circuit offset caused by device

mismatch

On-chip T-coils for improved return loss

I/Q Clock generation in the HF PLL

Low power CML Phase Rotators

DCVS sampling latches

IEEE 1149.6 compliant JTAG test receiver

Hardware Characterization modes:– Master Phase Rotator used to provide a controlled jitter injection to expand

manufacturing test coverage– Diagnostic sampling latches to characterize margins on functional data– Per lane control of I/Q relationship for in-situ link margin testing

Global Configuration Ring (GCR) support for receiver calibration, tune bit settings and test mode control

Page 30: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation30 8/26/2010

10Gb/s D-link & LR-link PHY Receiver Block Diagram

2:4Demux & Rx Align

ClkGen

De

Do

Ee

Eo

PhaseRotator

I

Q

CMLTo

CMOSClkDist DiagClk

DataClk

EdgeClk

Data Rot

Edge Rot

RegistersDiag Rot

Data<1:4>

Edge<1:4>

Data<1:10>AC

CoupledInput

CMOSToCML

ACJTAGTest

Driver

DiagBit

4:10Demux

&CDRLogic

C4clk

Data Rot, Edge Rot, Diag Rot

WrapMux

DiagLatch

DiagClk

PeakingAmp

2:1 Muxw/ OffsetControl

SamplingLatches

(with offset calibration)

Pol / PolB

Equal Delay

WrapData

I/QCorrection

DifferentialDataInput

Q Clock

I Clock

C4clk x 4φ

C10clk

C10 Clk

C20clkReg Interface

RX Input Eye Mask Performance– Eye height: 130mV– Eye Width: 20% UI

4.1 mW / Gb

Page 31: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation31 8/26/2010

Hardware Characterization @ 10Gb/s

DesignedCustom

CharacterizationHardware

Perform Transmitter Characterization

Perform Receiver Characterization

Perform Insitu End -to-end Link Characterization

System Hub-to-Hub Optical links have>25% UI of margin

@1e-15 error rate

Page 32: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation32 8/26/2010

Summary of Power7 Hub Chip Off-chip Interconnect

1.128 TB/s total Hub I/O Bandwidth achieved via Custom and Industry standard I/O– 528 GB/s of Single-ended EI-3 at 3.0 Gb/s– 560 GB/s of Differential Optical Link PHYs at 10 Gb/s

Differential Optical Link PHYs achieved high performance at low power– Transmitter achieved less than 17% UI Total Jitter @ 3.2mW / Gb– Receiver achieved greater than 80% UI Total Jitter Tolerance @ 4.1mW / Gb

End-to-end optical link performance in system operates with > 25% UI of margin at 1e-15 Error Rate

Page 33: Hot Chips 22 The IBM POWER7 HUB Module: A Terabyte ......Integrated Switch Router (ISR) Features Two tier, full graph network 3.0 GHz internal 56x56 crossbar switch – 8 HFI, 7 LL,

© 2010 IBM Corporation33 8/26/2010

Acknowledgements and References

Authors– Scott Clark, Baba Arimilli, Ben Drerup, Jerry Lewis, John Irish, David Krolak, Kerry

Imming, Joe McDonald, Andreas Koenig, Daniel Dreps, David Siljenberg, Steve Baumgartner, Glen Wiedemeier, Jim Strom, Dan OConnor, Andrew Maki, Dhaval Sejpal, Mark Ritter, Dave Friend and Charlie Geer

References– HOT Chips 19: The 3rd generation of IBM’s Elastic Interface (EI-3) Implementation of

POWER6

This material is based upon work supported by the Defense Advanced Research Projects Agency under its Agreement No. HR0011-07-9-0002.

Any opinions, findings and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the Defense Advanced Research Projects Agency.