Home Inspection Report
xxxxxx Dr, New Paltz, NY 12561
Inspection Date: 11/25/2015
Prepared By:
Foremost Home Inspections, LLC 837 No. Chodikee Lake Rd
Highland, NY 12528
Prepared For: Client ABC
Report Number:
1209_CY
Inspector: Robert Morton
NYS Home Inspector Lic# 16000062049
Owner/General Manager Ph: (845) 235-5126
First and Foremost “Provide the information you need to know to make an informed decision”
Page 2 of 36
This confidential report is prepared exclusively for Client ABC
Table of Contents
REPORT OVERVIEW 3
REPORT SUMMARY 5
GROUNDS / EXTERIOR COMPONENTS 7
STRUCTURAL COMPONENTS 11
ROOFING SYSTEM 13
GARAGE OR CARPORT 15
HEATING SYSTEM 16
COOLING / HEAT PUMP SYSTEM 19
PLUMBING SYSTEM 20
ELECTRICAL SYSTEM 23
INSULATION / VENTILATION 25
KITCHENS AND APPLIANCES 27
BATHROOMS AND LAUNDRY 29
INTERIOR COMPONENTS 31
AFTER YOUR INSPECTION 33
MAINTENANCE ADVICE 34
Page 3 of 36
This confidential report is prepared exclusively for Client ABC
Report Overview THE HOUSE IN PERSPECTIVE
The home was built circa 1876, had undergone renovation work and was situated in a pleasant setting. The recommendations
in this report should not be considered unusual for a home of this age, type of construction and location. It is not the intent of
this report to make the home or any of its components new again. Expect some hidden damage and less than expected
performance of building components and equipment. There is no such thing as a perfect home or an inspector who discovers
every defect during a one time visit to a property. Not all recommended upgrades identified in this report need to be done at
one time. The safety items identified should be addressed first and the remainder of the work itemized by priority and
budget. As with all homes, ongoing maintenance is required, but with recommendations in this report followed, the home
should serve you well.
PLEASE READ THE ENTIRE REPORT AT LEAST TWICE (INCLUDING PRE-CLOSING WALK THROUGH).
Building data
Date of inspection: November 25th, 2015
Time start / stop: Start: 11:30am ; Stop: 2:00pm
Attending inspection: Buyer, buyer's realtor
Residence type: Single family
Number of stories: Two
Garage / Carport: (3) car detached
Year built: Circa 1876
Front of home faces: North
Quantity of bedrooms and bathrooms: ( 3 ) Bedrooms, (2 ) Baths
Occupancy: Vacant
Temperature: 50 Degrees
Ground / soil surface condition: Dry
Precipitation in last three days: Dry
THE SCOPE OF THE INSPECTION
All components designated for inspection in the New York Department of State Standards of Practice are inspected, except as
may be noted in the “Limitations of Inspection” sections within this report.
This inspection was visual only. A representative sample of building components are viewed in areas that were accessible at
the time of the inspection. No destructive testing or dismantling of building components is performed.
The goal of the inspection was to put the home buyer in a better position to make an informed buying decision. Not all
improvements will be identified during the inspection. Unexpected repairs should still be anticipated. The inspection should
not be considered a guarantee or warranty of any kind.
Please refer to the pre-inspection contract for a full explanation of the scope of the inspection.
Your inspection report may or may not include thermal images that were obtained during the course of conducting your
inspection from a thermal imaging scan of elements of your home. Thermal imaging is a technology that allows us to show
you things about your home that are not evident using other visual inspection methods. Thermal imaging produces images of
invisible heat energy emitted from the surface of objects and systems in the home and allows us to measure it. Thermal
imaging can sometimes, but not always, help to identify and document anomalies found in electrical, plumbing and HVAC
systems in addition to helping to locate moisture problems and deficiencies with insulation installations. Although infrared
thermal imaging is a far better diagnostic tool than the naked eye, it does not guarantee 100% accuracy, unless removal or
destruction of components can be achieved to validate findings.
Page 4 of 36
This confidential report is prepared exclusively for Client ABC
IMPROVEMENT RECOMMENDATION HIGHLIGHTS
The entire report is an important tool for the client by identifying most of the potentially significant improvements that
should be budgeted for over the short and long term. Other significant improvements, outside the scope of this inspection,
may also be necessary. Please refer to the body of this report for further details on these and other recommendations.
Review the entire report and photographs for a comprehensive look at the subject property prior to the closing. Utilize the
report as a guide for subsequent repairs and improvements and do not hesitate to obtain other opinions from those with
specialized knowledge and skills with regard to any of the findings herein from the perspective of “there is no such thing as a
perfect house”.
CONVENTIONS USED IN THIS REPORT
Major Concern: A system or component that is considered significantly deficient or is unsafe. Significant deficiencies need
to be corrected and, except for some safety items, are likely to involve substantial cost.
Safety Issue: Denotes a condition that poses a safety hazard which should be addressed.
Repair/Evaluate: Denotes a system or component which is missing, which needs corrective action, or needs to be
evaluated by qualified professional to assure proper and reliable function.
Improve: Denotes discretionary improvements that are recommended, but not required right away and are relatively common
for a home of this age and location. These typically represent proactive actions that can help avoid a higher expense down the
road if acted upon in a timely manner.
Monitor: Denotes a system or component needing further investigation and/or monitoring in order to determine if
repairs are necessary.
Deferred Cost: Denotes significant improvements that are likely in the short term and typically involve higher cost, e.g. a
heating system that is currently functional but at or near end of useful life.
Serviceable Condition: Indicates the component is functionally consistent with its original purpose but may show signs of
normal wear and tear and deterioration.
Comment: Denotes additional general information and/or explanation of conditions, cosmetic issues, useful tips or suggestions
for home ownership.
Links: URL links (colored in blue) will bring you to a helpful web page by using Ctrl + click
Your report includes many photographs. Some pictures are intended as a courtesy and are added for your information.
Some are to help clarify where the inspection has been, what was looked at, and the condition of the system or
component at the time of the inspection. Some of the pictures may be of deficiencies or problem areas, provided to
help you better understand what is documented in this report and may allow you see areas or items that you normally
would not see. Not all problem areas or conditions will be supported with photos.
A qualified professional may be recommended to effect repairs/replacement of items called out in this report. Where
not specifically stated, this recommendation should be assumed as noted at the beginning of each section. Please
note that those observations listed under "Discretionary Improvements" are not essential repairs, but represent
logical long-term improvements/suggestions. Any professionals consulted or contracted stemming from report
recommendations should read the pages of the report that are relative to the concern.
Page 5 of 36
This confidential report is prepared exclusively for Client ABC
Report Summary
SUMMARY OF DEFECT / OBSERVATIONS
The following is a synopsis of the potentially significant improvements that should be budgeted for over
the short term along with other selected observations. Other significant improvements, outside the scope
of this inspection, may also be necessary. This summary does not contain all of the items and detailed
information called out in the body of the report. Please read the entire report twice to assure you
understand further details on these and other recommendations you may consider significant and/or
necessary.
Section Abbreviation Legend:
G&E: Grounds/Exterior Struc: Structure Roof: Roofing Gar: Garage
Heat: Heating Cool: Cooling Plum: Plumbing Elec: Electric
Insul: Insulation / Venting Kit: Kitchen B&L: Bath & Laundry Int: Interior
Major Item/Concern(s):
None apparent
Safety Recommendation(s): Add Ground Fault Circuit Interrupter (GFCI) protection to exterior receptacles (G&E) Do not use detached garage heating system until evaluated by qualified HVAC specialist (Gar) Furnace specialist or the fuel supplier perform inspection, cleaning, and servicing upon taking
possession of home. This should include evaluation of heating system venting, which was believed to be substandard (Heat)
Install knockout covers in main electrical service panel as needed to cover all open slots (Elec) Install GFCI protection on exterior outlet receptacle per standard building practices (Elec) Install an oven anti-tip bracket be installed to eliminate tipping exposure. This should be a
reasonably inexpensive and straight forward item to add by qualified person (Kit) Chimney sweep evaluate the fireplaces and wood stove and clean or repair as necessary prior to
usage (Int) Deficiency of carbon monoxide and smoke detector coverage was noted. The National Fire
Protection Association (NFPA) guidance calls for “a carbon monoxide detector centrally located outside of each separate sleeping area in the immediate vicinity of the bedroom(s) along with smoke detectors in every bedroom and on every floor”. Recommend improve alarm coverage per NFPA guidance as needed.
Deferred cost(s):
Visually, the roof covering material appeared to be in later portion of useful life. It would be wise to plan for repair / replacement costs within 5 years (Roof)
While the unit was functional at the time of inspection and may run well for a number of more years, it would be wise to plan for furnace repair / replacement costs (Heat)
The AC compressor was believed to be 25+ years old. Typical useful life for these types of units in the northeast is 15+ years. It would be wise to plan for repair / replacement costs (Cool)
Repair/Evaluate Item Recommendation(s): Qualified contractor who specializes in drainage issues evaluate and define possible improvement
actions that could help reduce basement water infiltration (Struc) Trained contractor evaluate support existing support posts to obtain further advice on improvements
needed, e.g. installing additional support columns per standard building practices (Struc) Roofing professional evaluate flashing details (around skylights, chimney, where exterior wall meets
roof) and repair or improve as needed (Roof)
Page 6 of 36
This confidential report is prepared exclusively for Client ABC
Qualified contractor evaluate metal bulkhead and repair or replace as needed (G&E) The HVAC air filter was not properly seated and sealed to avoid air leakage. Repair as part of heating
system evaluation (Heat) Improvement Recommendation(s):
Install weatherized door at base of bulkhead entrance per standard building practices to improve energy efficiency (G&E)
Clean gutters and downspouts now and as necessary in the future (G&E) Install clear plastic window well covers to reduce likelihood of moisture problems which are
conducive to wood-destroying organisms and wood rot (G&E) Upgrade exterior hose spigots to be frost-proof (G&E) Add gutter extensions as necessary to adequately move water away from foundation walls (G&E) Prune, move or remove vegetation as necessary to maintain at least 6 inches of space between it and
the building exterior. A 1-foot clearance is better (G&E) Repoint chimney(s) and repair any cracks in chimney crown as needed (Roof) Replace corroded copper fuel lines from storage tank to furnace and hot water heater per standard
building practices, e.g. re-run new fuel line that has protective coating. This should be a relatively inexpensive repair action that can be done by the boiler servicing company (Heat)
Terminate main waste pipe stub per stand building practices (Plumb) Improve the main service panel labeling to clearly identify individual all circuits they feed, so that in
an emergency, individual circuits can be quickly shut off (Elec) Replace existing rubber washer hoses with stainless steel braided reinforced washer hoses to reduce
risk of water related damage from burst washing machine hose(s) (B&L)
General Comment(s) / Recommendation(s):
Review seller disclosure statement
Confirm with seller any permits /approvals needed for upgrades since home was constructed, e.g.
detached garage, etc. were obtained from local municipality
Strongly recommend buried oil tank be properly decommissioned, with seller providing paperwork
documenting approval by local municipality
END OF SUMMARY
Page 7 of 36
This confidential report is prepared exclusively for Client ABC
Grounds / Exterior Components DESCRIPTION OF GROUNDS / EXTERIOR
Lot Grading & Drainage: Mix of positive grade away and level grade around home
Driveways: Appeared serviceable: Gravel
Walkways / Patios: Appeared serviceable: Pavers, Stone
Retaining Walls: None
Fencing / Gate: None
Porches, Decks, Balcony: None
Porches, Decks, Balcony Covering: N/A
Stairs, Steps: Appeared serviceable: Stone
Handrails: None
Guardrails: None
Soffit and Fascia: Appeared serviceable: Vinyl/Metal soffit, Wood fascia
Wall Cladding: Appeared serviceable: Wood
Flashing, Trim: Appeared serviceable: Metal, Wood
Exterior Entry Doors: Appeared serviceable: Wood, Metal bulkhead - Corrosion noted
- Recommend weatherize bulkhead - Comments below
Gutters, Downspouts, Extensions: Partially installed - Clogged with debris - Comments below
Vegetation Affecting Home: Area of vegetation in contact with home - Comments below
Wood Destroying Organisms: No visible evidence of active or previously treated infestation observed
Other Observations / Comments: Non-Frost free hose bibs noted, Non-GFCI exterior receptacles - Comments
in electrical section
GROUNDS / EXTERIOR OBSERVATIONS AND RECOMMENDATIONS
Grounds/Exterior Section Illustration
Comment: The overall exterior components of the home were in serviceable condition. The exterior siding was
observed to be lying flat, with no significant loose or damaged pieces noted. The fascia and soffits appeared in
serviceable condition. Window frames and trim were in serviceable condition. Exterior doors were opened and they
operated freely with satisfactory condition of hardware.
Repair; Corrosion of metal bulkhead was noted. Recommend
qualified contractor evaluate and repair or replace as needed.
Improve: Recommend install door at base of bulkhead entrance
per standard building practices to improve energy efficiency.
Page 8 of 36
This confidential report is prepared exclusively for Client ABC
Improve: Gutters were observed to full of leaves. Clogged
gutters can overflow and cause water to come in contact with the
building exterior, or water can accumulate around the
foundation. This is also a conducive condition for wood-
destroying organisms. Recommend cleaning gutters and
downspouts now and as necessary in the future.
Improve: Window wells without well covers were observed.
Recommend adding clear plastic window well covers to reduce
likelihood of moisture problems which are conducive to wood-
destroying organisms and wood rot.
Improve: Recommend upgrade exterior hose spigots to be frost-
proof. You can't see the frost-proof feature from outside. Unlike
a traditional hose spigot whose valve stem is 1 or 2 inches in
length, the valve stem for a frost-proof hose spigot (or sillcock)
could be 6 to 30 inches long. Thus, the valve is well within the
exterior wall and protected from cold and freezing.
Improve: Gutters without proper extensions were observed. This
can allow rain water discharge from gutters to come in contact
with the building exterior, or water can accumulate around the
foundation. It is also a conducive condition for wood-destroying
organisms and moisture related issues in basement. Recommend
adding gutter extensions as necessary to adequately move water
away from foundation walls.
Page 9 of 36
This confidential report is prepared exclusively for Client ABC
Safety: Exterior receptacles did not have Ground Fault Circuit
Interrupter (GFCI) protection. Although lacking GFCI circuit
protection may have been commonly been previously considered
safe or acceptable at the time the home was originally
constructed, as general knowledge of safe building practices has
improved with the passage of time, building standards have
changed to reflect current understanding. Additional information
can be found in the electrical section.
Improve: Vegetation in close proximity to building exterior
observed. Vegetation can serve as a pathway for wood-
destroying insects and can retain moisture against the exterior
after it rains. This is a conducive condition for wood-destroying
organisms. Recommend prune, move or remove vegetation as
necessary to maintain at least 6 inches of space between it and
the building exterior. A 1-foot clearance is better.
Comment: It is important that the caulking at wall penetrations, windows and trim is checked annually and maintained
in good condition to prevent water infiltration and damage to the siding system and other structural components. Painted
surfaces should be maintained in a good condition to preserve and protect the underlying materials from the weathering
effects of the elements. Recommend that routine maintenance is done on an annual basis to maintain the siding system in
a satisfactory condition and extend its useful life.
LIMITATIONS OF GROUNDS / EXTERIOR INSPECTION
As prescribed in the pre-inspection contract, this is a visual inspection only. The inspection of the exterior was limited by
(but not restricted to) the following conditions:
A representative sample of exterior components was inspected.
The inspection does not include an assessment of geological conditions and/or site stability.
Unless specifically included in the inspection, the following items and any related equipment, controls, electric systems
and/or plumbing systems are excluded from this inspection: detached buildings or structures; fences and gates; retaining
walls; underground drainage systems, catch basins or concealed sump pumps; swimming pools and related safety
equipment, spas, hot tubs or saunas; whether deck, balcony and/or stair membranes are watertight; trees, landscaping,
properties of soil, soil stability, erosion and erosion control; ponds, water features, irrigation or yard sprinkler systems;
sport courts, playground, recreation or leisure equipment; areas below the exterior structures with less than 3 feet of
vertical clearance; invisible fencing; sea walls, docks and boathouses; retractable awnings. Any comments made
regarding these items are as a courtesy only.
Page 10 of 36
This confidential report is prepared exclusively for Client ABC
Items excluded from this inspection include below-grade foundation walls and footings; foundations, exterior surfaces or
components obscured by vegetation, stored items or debris; wall structures obscured by coverings such as siding or trim.
Some items such as siding, trim, soffits, vents and windows are often high off the ground, and may be viewed using
binoculars from the ground or from a ladder. This may limit a full evaluation. Regarding foundations, some amount of
cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspection does not
determine the adequacy of seismic reinforcement.
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Page 11 of 36
This confidential report is prepared exclusively for Client ABC
Structural Components DESCRIPTION OF STRUCTURAL COMPONENTS
Foundation Design: Full basement (limited height)
Foundation Material: Appeared serviceable: Stone - Moisture ingress - Comments below
Basement Floor: Concrete , Gravel/dirt - Moisture noted - Comments below
Crawl Space Floor: N/A
Floor Carrying Beams: Wood
Apparent Floor structure: Wood joists
Support Post/Columns: Steel (3 inch column), Steel (Appeared temporary),
Wood - Comments below
Apparent Wall Structure: Wood frame
Apparent Ceiling Structure: Ceiling joists
Roof/Framing Structure: Rafter
Roof Sheathing: Wood planking
STRUCTURAL COMPONENT OBSERVATIONS AND RECOMMENDATIONS
Structural Component Section Illustration
Comment: The inspection did not discover evidence of substantial structural movement. When sighted down their length,
the exterior walls were observed to be straight and flat. The spans of visible joists and rafters appeared to be within
acceptable limits and no appreciable movement was noted when floors were ‘bounced upon’. The exterior plane of the
roof appeared reasonably even and flat consistent with age of the home.
Evaluate: Water intrusion noted in basement area. Review
disclosure statement and ask the property owner about past
accumulation of water in the basement. Trenches were cut into
basement floor which appeared would direct water intrusion to a
drain in basement floor. Recommend qualified contractor who
specializes in drainage issues evaluate and define possible
improvement actions. Ideally, water should not enter basement
spaces, but it is common in older homes with stone foundations.
If water must be controlled after it enters the basement, then
typical repairs include installing trenches, gravity drains and/or
sump pump(s) in the basement or improving underground
footing and/or curtain drains
Page 12 of 36
This confidential report is prepared exclusively for Client ABC
Evaluate: Substandard support posts were noted (wood and
temporary steel columns). Recommend evaluate by trained
contractor or qualified structural engineer to obtain further
advice on improvements needed, e.g. installing additional
support columns per standard building practices.
LIMITATIONS OF STRUCTURAL COMPONENT INSPECTION
As prescribed in the pre-inspection contract, this is a visual inspection only. Assessing the structural integrity of a building,
support columns, posts, chimney footings, etc. is beyond the scope of a typical home inspection. A certified professional
engineer is recommended where there are structural concerns about the building. Inspection of structural components was
limited by (but not restricted to) the following conditions:
Structural components concealed behind finished surfaces could not be inspected.
Only a representative sampling of visible structural components could be assessed at the time of the inspection.
Furniture and/or storage restricted access to some structural components.
Evaluation of detached structures was beyond scope of inspection and comments are as a courtesy for client information
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Page 13 of 36
This confidential report is prepared exclusively for Client ABC
Roofing System DESCRIPTION OF ROOFING SYSTEM
Style of Roof: Cross gable
Roof Covering: Appeared serviceable: Asphalt or fiberglass composite shingles - Believed
to be in mid to later portion of useful life - Comments below
Number of Layers: 2+ Layers - Comments below
Flashing: Appeared serviceable: Galvanized metal/aluminum , Asphalt
Chimneys: Masonry with metal liner - Recommend re-pointing - Comments below
Vents – Plumbing/Others: Plumbing
Skylights: Fixed
Method of Inspection: Partially traversed
ROOFING OBSERVATIONS AND RECOMMENDATIONS
Roofing System Section Illustration
Comment: The roof was believed to be covered with 2+ layers
of shingle material. Installing multiple layers of shingle material
has several disadvantages. These include extra weight that can
cause settling in some older homes, voids many guarantees and
warranties, shortens life span of roof as two layers trap more heat
and multiple shingle layers can trap moisture within that area,
which can cause premature wood rot and can affect proper
flashing details.
Deferred cost: Visually, the roof covering material appeared to
be in later portion of useful life. It would be wise to plan for
repair / replacement costs within 5 years.
Evaluate: Roofing professional evaluate flashing details (around
skylights, chimney, where exterior wall meets roof) and repair or
improve as needed.
Page 14 of 36
This confidential report is prepared exclusively for Client ABC
Improve: Repoint chimney(s) and repair any cracks in chimney
crown as needed.
Comment: Periodic inspection of the roof covering material and flashing is recommended as preventative maintenance
and to keep you apprised of the roof's condition. This is especially important after events that may cause physical damage,
such as a high-wind or hail storm.
LIMITATIONS OF ROOFING INSPECTION
As prescribed in the pre-inspection contract, this is a visual inspection only. Roofing life expectancies can vary depending on
several factors. Any estimates of remaining life are approximations only. This assessment of the roof does not preclude the
possibility of leakage. Leakage can develop at any time and may depend on rain intensity, wind direction, ice buildup, etc.
The inspection of the roofing system was limited by (but not restricted to) the following conditions:
Unable to mount roof due to roof height, slope and safety concerns
The entire underside of the roof sheathing is not inspected for evidence of leakage.
Evidence of prior leakage may be disguised by interior finishes. Number of layers may be difficult to determine.
The interior of ANY flue, chimney, stack, direct vented, fan assisted, fire box, woodstove, insert, fans, heatilators, solid
fuel devices and associated mechanical equipment such as pellet stoves, feeders, fans, thermostats or the required
installation, clearances and so on must be reviewed and inspected by professionals only and the adequacy of these
components cannot be determined during a limited visual inspection. A qualified HVAC, electrical and/or chimney
sweep should be consulted for further information and advice as well as servicing of the equipment and annual servicing
thereafter.
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Page 15 of 36
This confidential report is prepared exclusively for Client ABC
Garage or Carport DESCRIPTION OF GARAGE/CARPORT
Type: Three car - Detached
Garage door(s) material: Metal
Condition of Automatic Opener(s): Not installed
Mechanical Auto-Reverse Operable: Not installed
Garage Floor material: Appeared serviceable: Cement
Condition of Garage Interior: Appeared serviceable
Door Type Between Garage & Home: N/A
Garage Ventilation: Window
GFCI Branch Circuit Protection None apparent - Comments in electrical section
GARAGE/CARPORT OBSERVATIONS AND RECOMMENDATIONS
Garage/Carport Section Illustration
Safety: Recommend do not use garage heating system until
evaluated by qualified HVAC specialist
LIMITATIONS OF GARAGE/CARPORT INSPECTION
As prescribed in the pre-inspection contract, this is a visual inspection only. The inspection does not determine the adequacy
of firewall ratings. Requirements for ventilation in garages vary between municipalities.
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Page 16 of 36
This confidential report is prepared exclusively for Client ABC
Heating System DESCRIPTION OF HEATING SYSTEM
Primary Energy Source: Oil
Secondary Energy Source: Coal – Supplemental heat source
Heating System: Oil fired forced air furnace with supplemental coal furnace
Believed to be in later portion of useful life - Substandard venting -
Comments below
Heating System Shut Off Device: Switch at furnace
Heat Distribution Methods: Duct work - Improper filter installation – Comments below
Location of primary heating system: Basement
Fuel Storage and Distribution: Oil tank, copper fuel line - Corrosion of copper fuel line noted
Abandoned buried oil tank - Comments below
Fuel Shut off valves: At oil storage tank
Other Components: Electric air purification system- Comments below
HEATING SYSTEM OBSERVATIONS AND RECOMMENDATIONS
Heating System Section Illustration
Deferred cost: Based on manufacturer serial number dating
system, it was believed to be 20+ years old. The typical useful life
for this type of unit is 20+ years. While the unit was functional at
the time of inspection and may remain functional for a number of
more years, it would be wise to plan for repair / replacement costs.
Safety: Qualified furnace specialist or the fuel supplier perform
inspection, cleaning, and servicing upon taking possession of
home. This should include evaluation of heating system venting,
which was believed to be substandard, along with evaluation of
supplemental heat source coal furnace
Page 17 of 36
This confidential report is prepared exclusively for Client ABC
Repair: The HVAC air filter was not properly seated and sealed
to avoid air leakage. Repair as part of heating system evaluation.
Improve: The copper oil fuel lines supplying oil to the furnace an
hot water heater appeared corroded. This poses risk of oil leaking
into basement area. Recommend qualified person repair per
standard building practices, e.g. re-run new fuel line that has
protective coating. This should be a relatively inexpensive repair
action that can be done by the boiler servicing company.
Comment: An electronic air cleaning unit was installed in the
HVAC system. Recommend consult with seller if unfamiliar on
operation of the unit.
Comment: The home was reported to have a buried oil tank. Due to risk of oil leakage and possible significant amount of
fines that can be incurred, it is strongly recommended to have proper decommissioning of the buried tank per standard
building practices. Check with municipality on buried oil tank regulations and with your lending institution regarding any
financing requirements they may have for a home with a buried oil tank. More information about buried oil tanks can be
found on the EPA website link at the end of this report and below:
http://www.dec.ny.gov/chemical/32263.html
Page 18 of 36
This confidential report is prepared exclusively for Client ABC
LIMITATIONS OF HEATING INSPECTION
As prescribed in the pre-inspection contract, this is a visual inspection only. The inspection of the heating system is general
and not technically exhaustive. A detailed evaluation of the furnace heat exchanger is beyond the scope of this inspection.
The inspection was limited by (but not restricted to) the following conditions:
The adequacy of heat distribution or efficiency is difficult to determine during a one time visit to a home.
The interior of ANY flue, chimney, stack, direct vented, fan assisted, fire box, woodstove, insert, fans, heatilators, solid
fuel devices and associated mechanical equipment such as pellet stoves, feeders, fans, thermostats or the required
installation, clearances and so on must be reviewed and inspected by professionals only and the adequacy of these
components cannot be determined during a limited visual inspection. A qualified HVAC, electrical and/or chimney
sweep should be consulted for further information and advice as well as servicing of the equipment and annual servicing
thereafter.
The balancing or efficiency of the heating system cannot be determined during a one time visit to a home. Carbon monoxide detectors should centrally located outside of each separate sleeping area in the immediate vicinity of the bedroom.
Smoke detectors should be in every bedroom and on every floor.
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Page 19 of 36
This confidential report is prepared exclusively for Client ABC
Cooling / Heat Pump System DESCRIPTION OF COOLING / HEAT PUMP SYSTEM
Energy Source: 240 volt electric
System Type: Air cooled central air conditioning system, believed to be in later portion of
useful life - Not tested due to low outside air temperature - Comments below
Disconnect Location: At compressor
Manufacturer: Ruud
Location: Compressor on south facing exterior wall
Filter Location / Condition: At heat exchanger
Forced Air Ducts /Register Condition: Appeared serviceable
Estimated Age: Believed manufactured 1989
Condition of Controls: Comments below
Other Components: Air handler, ducting, filter, refrigerant line, low pressure line, disconnect
COOLING / HEAT PUMP SYSTEM OBSERVATIONS AND RECOMMENDATIONS
Cooling/Heat Pump Section Illustration
Deferred cost: The cooling system was not tested due to low
outside air temperature, which could cause damage to
compressor if operated. Based upon manufacturer serial number
dating system the unit was believed to have been manufactured
in 1989. Typical useful life for these types of units in the
northeast is 15+ years. It would be wise to plan for repair /
replacement costs in the near term. Recommend keep vegetation
clear around compressor unit.
LIMITATIONS OF COOLING / HEAT PUMP SYSTEM INSPECTION
As prescribed in the pre-inspection contract, this is a visual inspection only. Air conditioning and heat pump systems, like
most mechanical components, can fail at any time. The inspection of the cooling system was limited by (but not restricted to)
the following conditions:
Window mounted air conditioning units are not inspected.
The adequacy of distribution of cool air within the home is difficult to determine during a one-time inspection.
The balancing or efficiency of the cooling system cannot be determined during a one time visit to a home.
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Page 20 of 36
This confidential report is prepared exclusively for Client ABC
Plumbing System DESCRIPTION OF PLUMBING SYSTEM
Water Supply Source: Private well
Service Pipe to House: Appeared serviceable: Plastic
Main Water Valve Shutoff Location: Basement
Location Of Main Water Meter N/A - Private well
Functional flow: Appeared Serviceable: No noticeable drop in water flow with multiple
faucets and toilet operated simultaneously
Supply Piping: Appeared serviceable: Copper
Fixtures and Valves Condition: Appeared serviceable
Waste Disposal System: Apparent conventional system - septic tank/drain field - Comments below
Drain / Waste / Vent Piping: Appeared serviceable: Plastic , Cast iron , Improperly terminated waste
lines noted - Comments below
Main Waste Cleanout Location(s): Basement
Water Heater: Appeared serviceable: Oil fired - 40 Gallon capacity
Water Heater Manufacturer: Bock water heaters - Believed manufactured 2004
Water Heater Shut Off Valves: At water heater
Drain / Waste Ejectors Pumps: None apparent
Sump Pump Installed: None apparent
Distance Between Well and Septic: Greater than 100 feet
Other Components: Sediment filter, Water softener - Comments below
PLUMBING SYSTEM OBSERVATIONS AND RECOMMENDATIONS
Plumbing Section Illustration
Comment: The visible waste and water supply piping within the home appeared to be an adequate system (exception
noted). All drains operated freely. No leaks or sewer odors were detected. Overall condition of visible valves and supply
piping appeared satisfactory without significant corrosion observed. No significant drop in water flow rate was observed
when running faucets and flushing toilet simultaneously. The well pressure tank appeared in serviceable condition and
inspection did not find evidence of well pump short cycling when tested.
Comment: The hot water heater appeared to be in serviceable
condition. Based on manufacturers serial number dating system
the unit was believed to have been manufactured in 2004. These
types of units have a typical useful life of 8 - 12 years.
Page 21 of 36
This confidential report is prepared exclusively for Client ABC
Improve: Improper termination of a segment coming off main
waster line noted (duct tape). This can allow sewer gas to exit into
basement. Recommend terminate pipe stub per stand building
practices.
Comment: The home was believed to have a conventional system
- septic tank/drain field. Per information provided by seller during
the inspection, pumping of the septic tank pumping was scheduled
to be performed. Notations on the invoice should help identify the
type, size and location of the tank, whether any repairs are needed
and what condition the system is in. The tank should be pumped
every 5 years on average.
Comment: The home was equipped with a water softener system
and a sediment filter. If unfamiliar with using these types of
components recommend consult with seller on operation and
routine maintenance. This would include understanding any
warranty or lease information that may apply.
Sediment filters require routine replacement. Recommend
checking them twice a month after taking possession of home to
get a feel for how quickly they fill up for this particular home.
Higher or lower frequency of change may be needed. You may
want to consider replacing the sediment filter cartridge unit with a
self-cleaning filter type system. An example can be found at link
below. The advantage is you would not have to constantly replace
cartridges.
http://www.lowes.com/pd_31217-43353-
WHELJ1___?productId=1082883&pl=1&Ntt=filter
Page 22 of 36
This confidential report is prepared exclusively for Client ABC
Comment: In situations where a home is vacant for an extended period of time between the home inspection and before
taking occupancy, it is highly recommended to have the plumbing system checked for items such as possible frozen pipes
or risk of the water in the hot water heater experiencing bacterial growth, which can happen when the unit sits for an
extended period of time without any water flow (particularly if it was at temperature). Additional items to check are
described in the pre-closing walk through section of this report.
Comment: Recommend operate the main water valve at least annually to prevent the valve from freezing in the on
position and to help assure it will be operable when needed.
LIMITATIONS OF PLUMBING INSPECTION
As prescribed in the pre-inspection contract, this is a visual inspection only. The inspection of the plumbing system was
limited by (but not restricted to) the following conditions:
Water quality is not tested unless otherwise specified. The effect of lead content in solder and or supply lines is beyond
the scope of the inspection.
Pipes and valves concealed behind wall and insulation covering
The following items are not included in this inspection: private/shared wells and related equipment; private sewage
disposal systems; hot tubs or spas; main, side and lateral sewer lines; gray water systems; pressure boosting systems; trap
primers; incinerating or composting toilets; fire suppression systems; water softeners, conditioners or filtering systems;
plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs;
underground utilities and systems; overflow drains for tubs and sinks; back-flow prevention devices. Any comments
made regarding these items are as a courtesy only. Note that the inspection does not operate water supply or shut-off
valves due to the possibility of valves leaking or breaking when operated. The inspection does not test for lead in the
water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not
determine the existence or condition of underground or above-ground fuel tanks.
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Page 23 of 36
This confidential report is prepared exclusively for Client ABC
Electrical System DESCRIPTION OF ELECTRICAL SYSTEM
Primary Service Drop Type: Underground
Number of Service Conductors/Voltage: (3) conductors - split phase, 120-240V
Estimated Service Amperage: 200 Amps
Service Entrance Conductor Material: Appeared serviceable: Stranded Aluminum
Primary Service Overload Protection: Appeared serviceable: Circuit Breakers - Open breaker slot(s) -
Recommend improve labeling of main service panel circuit
breaker function
Main Disconnect Rating: 200 Amps
Main Distribution Panel: Appeared serviceable - Location: Basement
Service Grounding: Not determined, not readily apparent
Sub Panel(s): None apparent
Distribution Wiring: Copper non-metallic sheathed a.k.a. Romex
Solid Strand Aluminum Branch Wire Present: No evidence found
Switches and Receptacles: Grounded
Ground Fault Circuit Interrupters (GFCI) Present: Limited - Comments below
Arc Fault Circuit Interrupters (AFCI) Present: Not present - Comments below
ELECTRICAL OBSERVATIONS AND RECOMMENDATIONS
Electrical Section Illustration
Comment: Generally speaking, the electrical system was
observed to be in serviceable condition (exception noted).
Safety: A missing breakout knockout was observed on main
service panel. There should be no access into the panel
whatsoever. This is to prevent accidental electrocution by
someone being able to put a screwdriver or a finger into the
panel and touch a live component. Recommend qualified person
install knockout covers.
Improve: The circuit breakers were partially labeled as to
branch circuit they controlled. Recommend improve the main
service panel labeling to clearly identify individual all circuits
they feed, so that in an emergency, individual circuits can be
quickly shut off. It also protects against an unsafe condition
where the homeowner turns off a breaker, believing to have
killed the power on the circuit, only to find that s/he tripped the
wrong breaker.
Page 24 of 36
This confidential report is prepared exclusively for Client ABC
Safety: GFCI branch circuit protection was not found on exterior
outlets. Recommend a licensed electrician or other qualified
person evaluate and install GFCI protection where needed per
standard building practices. General guidelines for GFCI-
protected receptacles include the following locations:
* Outdoors (since 1973)
* Bathrooms (since 1975)
* Garages (since 1978)
* Kitchens (since 1987)
* Crawl spaces and unfinished basements (since 1990)
* Wet bar sinks (since 1993)
* Laundry and utility sinks (since 2005)
Comment: Some options for way this can be accomplished is
with replacing exiting receptacles with GFCI receptacle(s) or add
a GFCI circuit breaker back in the main service panel.
Improve: Arc Fault Circuit Interrupters were not observed in panel box. Effective January 1, 2002 all branch circuits
supplying 125V, single phase, 15- and 20-amp outlets installed in dwelling unit bedrooms are expected to be protected by
an arc-fault Circuit interrupter. AFCI's involve a technology that detects arcing-faults in electrical circuits, for example
frayed extension cords that could cause fires. Recommend adding AFCI protection to bedroom branch circuits per
standard building practices. Adding AFCI protection is straight forward and is done by replacing a standard breaker with
an AFCI breaker in a similar manner as adding a GFCI breaker.
Comment: It is important to distinguish AFCI devices from Ground Fault Circuit Interrupter (GFCI) devices. GFCIs
detect ground faults, which occur when current leaks from a hot (ungrounded) conductor to a grounded object as a result
of a short-circuit. This situation can be hazardous when a person unintentionally becomes the current’s path to the ground,
while AFCIs are designed to detect small arcs of electricity before they have a chance to lead to a structure fire.
LIMITATIONS OF ELECTRICAL INSPECTION
As prescribed in the pre-inspection contract, this is a visual inspection only. The inspection does not include low voltage
systems, telephone wiring, intercoms, alarm systems, TV cable, timers or smoke detectors. The inspection of the electrical
system was limited by (but not restricted to) the following conditions:
Electric turned off for branch circuits being tested
Electrical components concealed behind finished surfaces could not be inspected.
Only a representative sampling of outlets and light fixtures were tested.
Furniture and/or storage restricted access to some electrical components. Carbon monoxide detectors should centrally located outside of each separate sleeping area in the immediate vicinity of the bedroom.
Smoke detectors should be in every bedroom and on every floor.
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Page 25 of 36
This confidential report is prepared exclusively for Client ABC
Insulation / Ventilation DESCRIPTION OF INSULATION / VENTILATION
Attic inspection method: From attic access point
Location of attic access point: Scuttle hole - Recommend weather-stripping /insulation
Attic Insulation (Ceiling, skylight
chase, etc.)
Cellulose loose fill - Comments below
Wall insulation: Not visible – Comments below
Basement/Crawlspace insulation: None apparent
Vapor retarder: Not visible
Roof ventilation: Soffit, Gable
Mechanical Ventilation: None
INSULATION / VENTILATION OBSERVATIONS AND RECOMMENDATIONS
Insulation/Ventilation Section Illustration
Comment: Visible insulation levels were noted to be typical for
a home of this age and construction. No significant mildew or rot
was noted on the underside of the roof sheathing.
Comment: Unable to traverse attic area due to insulation
covering and limited access.
Comment: Due to the age of home construction and building
standards for insulation have increased significantly over time,
recommend consider a home energy assessment be done which
may point out inexpensive ways to save on energy cost via
weatherizing techniques. A home energy assessment is the first
step to assess how much energy your home consumes and to
evaluate what measures you can take to make your home more
energy efficient. An assessment will show you problems that
may, when corrected, save you significant amounts of money
over time. Most New York homeowners can receive a home
energy assessment for free or at reduced cost. A link to form for
requesting an energy audit is below:
https://nyserda.energysavvy.com/start-your-
project/hpwes/?s=contact
Page 26 of 36
This confidential report is prepared exclusively for Client ABC
LIMITATIONS OF INSULATION / VENTILATION INSPECTION
As prescribed in the pre-inspection contract, this is a visual inspection only. The inspection of insulation and ventilation was
limited by (but not restricted to) the following conditions:
The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due
to lack of access; areas and components obscured by insulation. Any comments made regarding these items are made as
a courtesy only. The inspection does not determine the adequacy of the attic ventilation system. Complete access to all
roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high/low
temperatures, high/low humidity, high wind and rain, melting snow) would be needed to do so. The inspection is not a
licensed engineer and does not determine the adequacy of roof structure components such as trusses, rafters or ceiling
beams, or their spacing or sizing.
Potentially hazardous materials such as Asbestos and Urea Formaldehyde Foam Insulation (UFFI) cannot be positively
identified without a detailed inspection and laboratory analysis. This is beyond the scope of the inspection.
An analysis of indoor air quality is beyond the scope of this inspection.
Any estimates of insulation R values or depths are rough average values.
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Page 27 of 36
This confidential report is prepared exclusively for Client ABC
Kitchens and Appliances DESCRIPTION OF KITCHEN AND APPLIANCES
Condition of Countertops: Appeared serviceable
Condition of Cabinets: Appeared serviceable
Condition of Sinks and Related
Plumbing:
Appeared serviceable
Permanently Installed Kitchen
Appliances Present During Inspection:
Refrigerator, Oven, Dishwasher, Garbage disposal, Trash compactor -
Comments below
Range, cook-top type: Electric
Anti-tip Oven Bracket Present: Not found (comments below)
GFCI Protection: Present
Appliance issues noted: None apparent
Point of use water filtration system: Not installed
KITCHEN AND APPLIANCES OBSERVATIONS AND RECOMMENDATIONS
Kitchen and Appliances Section Illustration
Comments: The faucet and related plumbing were in serviceable
condition. The cabinets and countertops were in serviceable
condition. No obvious damage, scratches or chips were observed.
All cabinet hardware tested was firm and operated smoothly. The
cabinets were firmly attached. The counters were secure. The
appliances were deemed to be in serviceable condition.
Comment: The home was equipped with a garbage disposal unit.
While these are fine to use with a home on a municipal sewer
system, recommend do not use as the home has a conventional
septic system. When a garbage disposal discharges into a septic
tank, it can place significant strain on the septic system. The
amount of waste that enters the tank, particularly grease and
suspended solids, will increase considerably. This load increase
requires that the septic tank be pumped more often than would
otherwise be required. The additional strain will also reduce the
life span of the septic system. Septic systems can be designed to
accommodate food waste but, in general, they are not.
Safety: No anti-tip bracket appeared to be installed behind the
oven. This poses a risk the range may tip forward when weight is
applied to the open door, such as when a small child climbs on it,
or if heavy objects are dropped on it. Anti-tip brackets have been
sold with all free standing ranges since 1985. Recommend an
oven anti-tip bracket be installed to eliminate tipping exposure.
This should be a reasonably inexpensive and straight forward item
to add by qualified person.
Page 28 of 36
This confidential report is prepared exclusively for Client ABC
Note: Although a basic check of existing kitchen appliances was performed during the inspection, no representation can
reasonably be made as to the life expectancy of any appliance, as they can break down without notice regardless of age.
Kitchen appliances present within the home at the time of inspection may not necessarily be included in the sale. Included
appliances should be specified in the sales contract. Also, please be aware that the appliances present during the inspection
may not be the same appliances present after the sale. Therefore, the brands and model numbers of appliances should be
specified in the sales contract. All appliances should be retested on the final walk-through prior to closing, as it should be
noted that a typical sales contract will provide for functionality of all appliances listed on it (however, check with your
attorney to be sure, as sales contracts can vary).
LIMITATIONS OF KITCHENS AND APPLIANCES INSPECTION
As prescribed in the pre-inspection contract, this is a visual inspection only. The inspection of the kitchen was limited by
(but not restricted to) the following conditions:
The following items are not included in this inspection: household appliances such as stoves, ovens, cook tops, ranges,
warming ovens, griddles, broilers, dishwashers, trash compactors, refrigerators, freezers, ice makers, hot water
dispensers and water filters; appliance timers, clocks, cook functions, self and/or continuous cleaning operations,
thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only.
Note that the inspection does not provide an estimate of the remaining life of appliances, and does not determine the
adequacy of operation of appliances. The inspection does not note appliance manufacturers, models or serial numbers
and does not determine if appliances are subject to recalls. Areas and components behind and obscured by appliances are
inaccessible and excluded from this inspection.
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Page 29 of 36
This confidential report is prepared exclusively for Client ABC
Bathrooms and Laundry DESCRIPTION OF BATHROOMS AND LAUNDRY
Condition of Countertops: Appeared serviceable
Condition of Cabinets: Appeared serviceable
Condition of Flooring: Appeared serviceable
Condition of Sinks & Related Plumbing: Appeared serviceable
Condition of Toilets: Appeared serviceable
Condition of Bathtubs/Showers /Related
Plumbing:
Appeared serviceable
Bathroom Ventilation Type: Windows
Gas Supply For Laundry Equipment
Present:
No
240 Volt Receptacle For Laundry
Equipment:
Yes
GFCI Protection: Present
Laundry Plumbing Connections: Hot and Cold Water Supply for Washer, Waste Standpipe for Washer - Use
of Rubber hoses
Laundry Dryer Venting: Present
Appliances Present: Washer, Dryer
BATHROOMS AND LAUNDRY OBSERVATIONS AND RECOMMENDATIONS
Bathroom and Laundry Section Illustration
Comment: The bathroom fixtures were in serviceable condition.
The sinks drained as expected when the stoppers. Faucets were
secure and gave water with no leaks. The sinks and toilets were
firmly secured. The toilets flushed completely. The tub/shower
surrounds were in serviceable condition. No serious damage,
scratches of countertops or cabinetry was noted. The flooring was
in serviceable condition. No evidence of moisture related issues
were noted.
Improve: Recommend replacement of existing rubber washer
hoses with stainless steel braided reinforced washer hoses to
reduce risk of water related damage from burst washing machine
hose(s)
Page 30 of 36
This confidential report is prepared exclusively for Client ABC
Note: Although a basic check of existing laundry appliances was performed during the inspection, no representation can
reasonably be made as to the life expectancy of any appliance, as they can break down without notice regardless of age.
Laundry appliances present within the home at the time of inspection may not necessarily be included in the sale. Included
appliances should be specified in the sales contract. Also, please be aware that the appliances present during the inspection
may not be the same appliances present after the sale. Therefore, the brands and model numbers of appliances should be
specified in the sales contract. All appliances should be retested on the final walk-through prior to closing, as it should be
noted that a typical sales contract will provide for functionality of all appliances listed on it (however, check with your
attorney to be sure, as sales contracts can vary).
LIMITATIONS OF BATHROOMS AND LAUNDRY INSPECTION
As prescribed in the pre-inspection contract, this is a visual inspection only. The inspection of the plumbing system was
limited by (but not restricted to) the following conditions:
Components concealed behind finished surfaces could not be inspected.
The bathtub overflow drain(s) are not tested.
Any comments made regarding laundry appliances are as a courtesy only. Note that the inspection does not provide an
estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances. The
inspection does not note appliance manufacturers, models or serial numbers and does not determine if appliances are
subject to recalls. Areas and components behind and obscured by appliances are inaccessible and excluded from this
inspection.
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Page 31 of 36
This confidential report is prepared exclusively for Client ABC
Interior Components DESCRIPTION OF INTERIOR
Interior doors: Appeared serviceable: Wood
Windows: Appeared serviceable: Double hung Vinyl - double pane, Double hung Wood
- single pane, Casement
Wall type or covering: Appeared serviceable: Drywall or plaster
Ceiling type or covering: Appeared serviceable: Drywall or plaster
Flooring type or covering: Appeared serviceable: Carpet , Wood , Vinyl, Tile
Stairs, handrails and guardrails: Appeared serviceable:
Woodstove(s): Gas Stove(s): Metal (Manufactured)
Fireplace(s): Wood burning - masonry firebox - Comments below
Vents, Flues, Chimneys Masonry chimneys (Metal liner)
Smoke and CO Detectors: Limited
INTERIOR COMPONENTS OBSERVATIONS AND RECOMMENDATIONS
Interior Section Illustration
Comment: Overall, the interior finishes of the home appeared in
serviceable condition. A sample of windows and all doors were
opened and appeared to operate freely. No corroded parts or
inoperable hardware was noted in the windows that were opened.
The floors appeared level and the walls appeared were plumb
when put in perspective the age of the home. No evidence of
moisture stains on interior walls or ceilings was noted
Safety: The National Fire Protection Association guidance states
a “Level 2" chimney inspection should be performed with the
sale or transfer of property with a wood-burning device.
Recommend chimney sweep or other qualified specialist
evaluate the fireplaces and wood stove and clean and repair as
necessary prior to usage.
A Level 2 inspection includes a visual inspection by video
scanning or other means in order to examine the internal surfaces
and joints of all flue liners incorporated within the chimney.
More information can be found at at:
http://www.csia.org/homeowner-
resources/chimney_inspections.aspx#sthash.2KwkA1yJ.dpuf
Page 32 of 36
This confidential report is prepared exclusively for Client ABC
Safety: Limited coverage of smoke and carbon monoxide detector coverage was observed. Recommend follow the
National Fire Protection Association (NFPA) guidance: "A carbon monoxide detector be centrally located outside of each
separate sleeping area in the immediate vicinity of the bedroom and smoke detectors should be in every bedroom and on
every floor”
LIMITATIONS OF INTERIOR INSPECTION
As prescribed in the pre-inspection contract, this is a visual inspection only. Assessing the quality and condition of interior
finishes is highly subjective. Issues such as cleanliness, cosmetic flaws, quality of materials, architectural appeal and color
are outside the scope of this inspection. Comments will be general, except where functional concerns exist. No comment is
offered on the extent of cosmetic repairs that may be needed after removal of existing wall hangings and furniture. The
inspection of the interior was limited by (but not restricted to) the following conditions:
A representative sampling of windows opened and closed
Furniture, storage, appliances and/or wall hangings restricted the inspection of the interior.
Equipment, sub-flooring, woodstove inserts (make, model, compliance and so on) or manufacturer’s specifications.
The temperature calibration, effectiveness and efficiency of appliances is outside the scope of this inspection.
Thermostats, timers and other specialized features and controls are not tested.
Components concealed behind finished surfaces could not be inspected.
The bathtub overflow drain(s) are not tested.
The interiors of flues or chimneys are not inspected.
Fire screens, fireplace doors, appliance gaskets and seals, automatic fuel feed devices, mantles and fireplace surrounds,
combustion make up air devices, and heat distribution assists (gravity or fan-assisted) are not inspected.
The inspection does not involve igniting or extinguishing fires nor the determination of draft.
Fireplace inserts, stoves, or firebox contents are not moved.
The gas supply to the house was shut off.
Evaluation of radon systems are beyond scope of inspection. A radon test could be done upon request to confirm proper
function Carbon monoxide detectors should centrally located outside of each separate sleeping area in the immediate vicinity of the bedroom.
Smoke detectors should be in every bedroom and on every floor.
Please also refer to the pre-inspection contract for a detailed explanation of the scope of this inspection.
Page 33 of 36
This confidential report is prepared exclusively for Client ABC
After Your Inspection
RECOMMENDATION FOR THE PRE-CLOSING WALK THROUGH
The walk-through prior to closing is the time for Client to inspect the property. Conditions can change between the time of a
home inspection and the time of closing, e.g. burst pipes from water freezing when house was vacant during an extended
period from inspection date to closing date. Restrictions that existed during the inspection may have been removed for the
walk-through. Defects or problems that were not found during the home inspection may be discovered during the walk-
through. Client should be thorough during the walk-through. Any defect or problem discovered during the walk-through
should be negotiated with the owner/seller of the property prior to closing. Purchasing the property with a known defect or
problem releases Foremost Home Inspections of all responsibility. Client assumes responsibility for all known defects after
settlement.
The following are recommendations for the pre-closing walk through your new house. Consider hiring a certified home
inspector to assist you.
1. Check the heating and cooling system. Turn the thermostat to heat mode and turn the temperature setting up. Confirm that
the heating system is running and making heat. Turn the thermostat to off and wait 20 minutes. Turn the thermostat to cool
mode and turn the temperature setting down. Confirm the condenser is spinning and the system is making cool air. The
cooling system should not be checked if the temperature is below 60 degrees or if the temperature was below freezing the
night before the walk-through. And you should not operate a heat pump in the heating mode when it is over 75 degrees
outside.
2. Operate all appliances.
3. Run water at all fixtures (both hot and cold water) and flush toilets. Look for plumbing leaks.
4. Operate all exterior doors, windows, and locks.
5. Test smoke and carbon monoxide detectors.
6. Ask for all remote controls to any garage door openers, fans, gas fireplaces, etc.
7. Inspect areas that may have been restricted at the time of the inspection.
8. Ask seller questions about anything that was not covered during the home inspection.
9. Ask seller about prior infestation treatment and warranties that may be transferable.
10. Read the seller's disclosure.
Page 34 of 36
This confidential report is prepared exclusively for Client ABC
Maintenance Advice UPON TAKING OWNERSHIP
After taking possession of a new home, there are some maintenance and safety issues that should be addressed immediately.
The following checklist should help you undertake these improvements:
Change the locks on all exterior entrances, for improved security.
Check that all windows and doors are secure. Improve window hardware as necessary. Security rods can be added to
sliding windows and doors. Consideration could also be given to a security system.
Install smoke detectors in each bedroom and on each floor. Ensure that there is a smoke detector outside all sleeping
areas. Replace batteries on any existing smoke detectors and test them. Make a note to replace batteries again in one
year.
Install carbon monoxide detectors.
Create a plan of action in the event of a fire in your home. Ensure that there is an operable window or door in every
room of the house. Consult with your local fire department regarding fire safety issues and what to do in the event of
fire.
Examine driveways and walkways for trip hazards. Undertake repairs where necessary.
Examine the interior of the home for trip hazards. Loose or torn carpeting and flooring should be repaired.
Undertake improvements to all stairways, decks, porches and landings where there is a risk of falling or stumbling.
Review you home inspection report for any items that require immediate improvement or further investigation. Address
these areas as required.
Install rain caps and vermin screens on all chimney flues, as necessary to prevent water intrusion and vermin entry.
Investigate the location of the main shut-offs for the plumbing, heating and electrical systems. If you attended the home
inspection, these items would have been pointed out to you.
REGULAR MAINTENANCE
EVERY MONTH
Check that fire extinguisher(s) are fully charged. Re-charge if necessary.
Examine heating/cooling air filters and replace or clean as necessary.
Inspect and clean humidifiers and electronic air cleaners.
If the house has hot water heating, bleed radiator valves.
Clean gutters and downspouts. Ensure that downspouts are secure, and that the discharge of the downspouts is
appropriate. Remove debris from window wells.
Carefully inspect the condition of shower enclosures. Repair or replace deteriorated grout and caulk. Ensure that water
is not escaping the enclosure during showering. Check below all plumbing fixtures for evidence of leakage.
Repair or replace leaking faucets or shower heads.
Secure loose toilets, or repair flush mechanisms that become troublesome.
Check washing machine water hoses and replace with stainless-steel braided hose every 3-5 years.
SPRING AND FALL
Examine the roof for evidence of damage to roof coverings, flashings and chimneys.
Look in the attic (if accessible) to ensure that roof vents are not obstructed. Check for evidence of leakage, condensation
or vermin activity. Level out insulation if needed.
Trim back tree branches and shrubs to ensure that they are not in contact with the house.
Inspect the exterior walls and foundation for evidence of damage, cracking or movement. Watch for bird nests or other
vermin or insect activity.
Survey the basement and/or crawl space walls for evidence of moisture seepage.
Page 35 of 36
This confidential report is prepared exclusively for Client ABC
Look at overhead wires coming to the house. They should be secure and clear of trees or other obstructions.
Ensure that the grade of the land around the house encourages water to flow away from the foundation.
Inspect all driveways, walkways, decks, porches, and landscape components for evidence of deterioration, movement or
safety hazards.
Clean windows and test their operation. Improve caulking and weather-stripping as necessary. Watch for evidence of
rot in wood window frames. Paint and repair window sills and frames as necessary.
Test all ground fault circuit interrupter (GFCI) devices, as identified in the inspection report.
Shut off isolating valves for exterior hose bibs in the fall, if below freezing temperatures are anticipated.
Test the Temperature and Pressure Relief (TPR) Valve on water heaters.
Inspect for evidence of wood boring insect activity. Eliminate any wood/soil contact around the perimeter of the home.
Test the overhead garage door opener, to ensure that the auto-reverse mechanism is responding properly. Clean and
lubricate hinges, rollers and tracks on overhead doors.
Replace or clean exhaust hood filters.
Clean, inspect and/or service all appliances as per the manufacturer’s recommendations.
ANNUALLY
Replace smoke detector and carbon monoxide detector batteries.
Have the heating, cooling and domestic water heater systems cleaned and serviced.
Have chimneys inspected and cleaned. Ensure that rain caps and vermin screens are secured.
Examine the electrical panels, wiring and electrical components for evidence of overheating. Ensure that all components
are secure. Flip the breakers on and off to ensure that they are not sticky.
If the house utilizes a well, check and service the pump and holding tank. Have the water quality tested. If the property
has a septic system, have the tank inspected (and pumped as needed).
If your home is in an area prone to wood destroying insects (termites, carpenter ants, etc.), have the home inspected by a
specialist. Preventative treatments may be recommended in some cases.
PREVENTION IS THE BEST APPROACH
Although we’ve heard it many times, nothing could be truer than the old cliché “an ounce of prevention is worth a pound of
cure.” Preventative maintenance is the best way to keep your house in great shape. It also reduces the risk of unexpected
repairs and improves the odds of selling your house at fair market value, when the time comes.
Reference Websites
Mold guideline: www.epa.gov/mold/moldguide.html
NYS Buried Fuel Tank: www.dec.ny.gov/chemical/32263.html
Water Supply Systems/Wells: http://water.epa.gov/drink/
Natural/LP Gas: www.naturalgas.org
Lead Paint: www.epa.gov/lead
Radon: www.epa.gov/radon
Carbon Monoxide: http://www.epa.gov/iaq/co.html
Asbestos: www.epa.gov/asbestos
NYSERDA Energy Audit website: https://nyserda.energysavvy.com/start-your-project/hpwes/?s=contact
Page 36 of 36
This confidential report is prepared exclusively for Client ABC
Respectfully submitted,
Robert Morton
Robert Morton
Owner / General Manager
Foremost Home Inspections, LLC