Upload
others
View
13
Download
0
Embed Size (px)
Citation preview
www.hicop.co.id
Contents
2
Company Profile
Qualification Certificates
Heating Price Performance Ratio
Air to Water Heat Pump
Air to Water With Pump
Swimming Pool Heat Pump
Swimming Pool Portable Series
All In One Heat Pump
High Temperature Heat Pump
Water to Water Heat Pump
Multifunction Titanium Heat Pump
Dryer Heat Pump
Split Type
Water Chiller
Mini Tank
Commercial Tank
Gas Water Heater
Project References
............................................................ 3
................................................ 4
.................................. 5
........................................... 6 - 7
............................................ 8 - 9
.................................. 10 - 11
........................... 12 - 13
.......................................... 14 - 15
............................... 16 - 17
......................................................... 18
......................... 20 - 21
.................................................. 22 - 23
….......................................................... 24 - 25
......................................................... 26 - 27
.............................................................. 28 - 29
................................................. 30 - 31
........................................................ 32
............................................... 33 - 39
3
CompanyProfile
In 2009, the Company introduced
Heatpump water heater to
Indonesia.
The Company devotes to specialize
in distributing energy-eficient heat
pump and hot water unit, mainly for
guesthouses, hotels, schools,
offices, factories, hospitals and villas
all over Indonesia, to provide
energy-saving central heating and
hot water systems solutions, of
which rate can be 75% or higher.
In 2014, HiCOP introduced High
Temperature Heat Pump to
subsitute boilers for industries. With
High Coefficient of Performance (Hi
COP), this unit more efficient and
environmentally friendly.
HiCOP also introduced duplex tank
with high quality material.
In 2018, the company introduced
Gas Water Heater. This variance is
the beginning for HICOP to join the
retail market for small appliances
As leader in heat pump water
heater, our services included
products design, product
consultation and after sales
service.
We have excellent experience,
passionate work force and strong
after sales service which make
possible to provide the highest
level of service and speedy
response to market demand.
Our product go through strict
international regulation test and our
quality control process to ensure
the high standard of quality before
delivery.
PT. Simed Prakarsa Indonesia has established in 1982 and distribute
water heater of famous brands: Solahart Water Heater, Handal Water
Heater, Raypak Water Heater and HiCOP Heatpump Water Heater.
4
• Adoping International standard
product marking certificate
• SGS CE certificate 3
• TUV CE certificate 3
• TUV CE certificate 9
• Declaraion of the strategic
partner with American Copeland
• SGS CE certificate 4
• TUV CE certificate 4
• TUV CE certificate 10
• High-tech products certificate
• SGS CE certificate 5
• TUV CE certificate 5
• TUV CE certificate 11
• ISO9001 certificate
• SGS CE certificate 6
• TUV CE certificate 6
• TUV CE certificate 12
• SGS CE certificate 1
• TUV CE certificate 1
• TUV CE certificate 7
• TUV CE certificate 13
• SGS CE certificate 2
• TUV CE certificate 2
• TUV CE certificate 8
• TUV CE certificate 14
Qualification Certificates
4
Heating Price
Heat Pump compared to other water heater systemThe following drawings are calculated in an electricity bill
of 0.11 USD, the actual costs shall be calculated
preferentially based on local unit price
- Inlet temperature 150C, Ambient Temperature 200C, Target Temperature 550C
Name Safety Equipment
Lasting LifePractical Utility
HiCOP
Heat PumpSafe Up to 15 Years
Low power consumtion,
safe, eco-friendly
Solar Heater Relatively
Safe3-8 years
Be affected by weather
changes, Unstable water
temperature, Need
electrical heater back up
when In raining or cloudy
days
Electric
Heater
Relatively
Safe3-5 years
High running cost,
Fear of electricity
leakage accidents
Gas
Heater
Relatively
Safe3-5 years
May happen gas
explosion, toxic, not
allowed to installed indoor
Coal boil
Heater
Relatively
Safe5-8 years
Pressure devices,
pollution, need specialist
security check annually
Performance RatioEconomic Value Comparison Table
Heating TypeCalorie of
Energy
Energy/
Performance
Ratio
Unit Price
Required
Energy
(per ton water)
Required Cost
(Per ton water)
All Year Cost
(10 Ton water
per day)
Labor Cost Coverage
Annual
Operation
Cost
Coal Boiler 4000Kcal/kg 40% $0.08/kg 25.10kg $2.32 $7,513 $5,128 20M3 $12,641
Oil Boiler 8429Kcal/kg 80% $0.6/l 6.40 l $3.84 $14,012 $5,128 20M3 $19,141
Liquefied Gas 10800Kcal/kg 73% $0.85/kg 5.30kg $4.48 $16,371 $2,564 10M3 $18,936
Solar Electric
Heating860Kcal/Kwh 85% $0.09/Kwh 51.6Kwh $1.92 $7,026 NO 150m2 $7,026
Electric Boiler 860Kcal/Kwh 90% $0.09/Kwh 51.6Kwh $4.63 $13,487 NO 10-15M3 $13,487
HiCOP 860Kcal/Kwh 400% $0.09/Kwh 13Kwh $1.17 $4,256 NO 3-10M3 $4,256
5
1. Copeland with R417a or Daikin with
R410a scroll compressor, high efficiency
and stable functions.
2. Emerson ALCO thermal expansion valve,
with accurate and stable throttling
performance.
3. Al-Mg fan motor with Nylon fan blades,
low noise, low power consumption, big air
blow volume.
4. High efficiency Tube in tube heat
exchangers, low fouling and easy for
maintenance.
5. Coated steel or SUS304# stainless steel
case, avoiding rust effectively and
durable.
Air To Water
Heat Pump
Overview
Features
HIGH COP
Using high technology of heatpump, make the
HiCOP air to water heatpump COP can reach to 4.
HIGH WATER TEMP 600C
The water temperature arrived at 600C and can be
widely applied in preparation for heating and hot
water.
QUIET RUNNING
Using efficient, low noise, closed famous brand
compressor and fan, ensure quiet running.
EXTREMELY COLD TEMP.
HiCOP Heatpump can work securely and stable
under -10 0C extremely cold environment, and
normally provide hot water.
6
Construction
Item Description
Compressor Copeland Flexible Scroll
Refrigerant R417a
Expansion Valve Emerson
Cabinet Powder Coated Steel
Water Ingress ProtectionRating IPx4
Heat Exchanger Coaxial Coil, Tube inTube
Controller Multi-Function Digital
Fan Fibre Nylon
Fan Motor Alumunium Magnesium Alloy
Working Principle
Note :
Heating Outdoor Air temp : 20oC/15oC, Water tank water temperature from 150C heating to 550C.
HiCOP reserves the right to discontinue, or charge at any time, specification or designs without notices and without incurring obligations.
Model AW-10 AW-15 AW-21 AW-30 AW-37 AW-42 AW-62 AW-72 AW-90 AW-105
Power Supply 220/1/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50
* Heating Capacity kW 9.5 15 20.8 30 37.5 42 62 72 90 105
* Rated Power Input kW 2.5 3.6 5.2 7.5 9.2 10.5 15 18.5 22,5 27
Water Feed Speed L/H 204 322 430 645 806 938 1330 1548 2063 2257
Max. Current A 19.5 10 15 21 25 28.5 40.5 49 61 73.5
Rared Water Temp OC 55 55 55 55 55 55 55 55 55 55
Max. Water Temp 60 60 60 60 60 60 60 60 60 60 60
Level against electric shock | | | | | | | | | | |
Net Weight Kg 100 145 165 260 275 295 495 622 670 893
Net Sizemm
(L*W*H)
690 x700
x800
870 x830
x970
800 x800
x 1120
1200 x920
x1220
1200 x920
x1220
1200 x970
x1425
2080 x1100
x1676
2200 x1135
x2080
2400 x1130
x2300
2400 x1300
x2080
Required water flow rate m3/h 2.2 3.2 5 6 8 10 12 16 20 24
Required tank cubage 2-3 2-3 3-5 5-8 7-10 18-12 10-15 15-20 20-30 25-30
Water connection G1” G1” G1” G1-1/4” G1-1/4” G1-1/4” G2” G2” G2” G2-1/2”
Operation temp. range OC -10-45 -10-45 -10-45 -10-45 -10-45 -10-45 -10-45 -10-45 -10-45 -10-45
Noise db(A) <56 <56 <60 <60 <60 <60 <62 <64 <68 <65
7
Air To Water
With Pump
Timing water supply,
automatic constants water
supply, automatic
pressurized water supply.
The heat pump utilizes smart
defrosting technology, reduce the
defrosting time and extend the
poll heating time.
500-step liner electronic
expansion valve throttle control
wide adjustable refrigerant flow
control range.
The design is suitable for
commercial, industrial,
agricultural places with large
hot water demands.
Unit is designed with electronic
water flow protection, compress
or exhaust temp, protection,
compressor high/low pressure
protection.
Unit designed with multi-grade
antifreeze protection control
function. When outdoor ambient
temperature is lower than setting
function.
Automatic heating, automatic
temperature maintaining.
Automatic record of the working
mode before recovery of the
recorded working mode after
power failure.
Featured with block up slopes on
bottom, the chassis is easier to
drain condensate water. Built-in
stainless steel heating belt on
chassis for condensate anti-
freeze protection.
The Heat pump units are with
Timing ON/OFF function and two
sections can be set at the same
time.
Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.
OverviewHiCOP cycle heating type heat pump hot water heater is the best choice for places where hot water
is in demand such as private house, villas, restaurants, hotels, beauty salons, fitness centers, SPA
and massage centers, public baths, hospitals, dormitories, factories, aquaculture farms, etc. With
outstanding features of high efficient and energy-saving, safe and reliable, environmental-friendly
and comfortable, low operation costs, etc, it' s a direct replacements for traditional hot water devices
like coal, oil and gas boilers.
8
Meet the hot water demand all-year-round in
different places.
Maximum outlet water temperature can reach 60oC
under - 20oC outdoor without auxiliary electric heater.
Superior Heating Performance In Low Temperature
High efficient scroll compressor, 25% larger heat
exchange area than ordinary heat pump
products.
High Water Outlet Temperature DesignWide Working Ambient Temperature Range
This heat pump is complete with circulation
pump.
Note :
Heating Outdoor Air temp : 20oC/15oC, Water tank water temperature from 150C heating to 550C.
HiCOP reserves the right to discontinue, or charge at any time, specification or designs without notices and without incurring obligations.
Circulation Pump
9
Model AWP - 10 AWP - 15 AWP - 21 AWP - 25 AWP -35 AWP - 42
Heating Capacity kw 10.5 15 21 24.5 35 42
Input Power kw 2.59 3.6 5.19 6.76 8.64 10.37
Input Curent A 11.8 5.5 7.9 10.3 13.1 15.8
Rated Output Water L/h 225 300 450 525 600 700
Refrigerant R410A
Power Supply V/ph/Hz 220/1/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50
Compressor Scroll
Compressor QTY 1 1 1 1 2 2
Max. temp. of water output 0C 60
Fan QTY 1 1 1 1 2 2
Fan Direction Vertical
Water flow volume m3/h 2.5 2.5 3.5 4.3 6 7
Water Outlet/Water Inlet inch 1" 1" 1" 1" 1 - 1/4" 1 - 1/4"
Noise dB dB(A) 52 55 55 56 59 62
Unit Net Dimension L/M/H760/704
/770
860/806
/970
860/806
/970
780/890
/1182
1450/730
/1260
1450/730
/1260
Nett Weight Kg 80 95 120 196 260 280
8
Swimming Pool
Heat Pump
1. Copeland with R417a or Daikin with R410a
scroll compressor, high efficiency and stable
functions.
2. Emerson ALCO thermal expansion valve,
with accurate and stable throttling
performance.
3. Al-Mg fan motor with Nylon fan blades, low
noise, low power consumption, big air blow
volume.
4. Adopt Titanium Heat Exchanger,
effectively erosion proof and durable.
5. Coated steel or SUS304# stainless steel
case, avoiding rust and durable.
Overview
Features
HIGH COP
Using high technology of heatpump, make the HiCOP
swimming pool heatpump COP can reach to more than
4.7
HIGH TEMPERATURE 450C
HiCOP swimming pool heat pump can reach 45 0 C of
temperature, it is applicable for spa.
100% TITANIUM HEAT EXCHANGER
Using advanced titanium heat exchanger, greatly resist
erosion of chlorine ion in pool water and durable.
SAFE AND GREEN
HiCOP uses the heat pump technology to heat
swimming pool water, which realize the separation
between water electricity.
Compare with gas heater system, heat pump is
flameless and has no exhaust gas.
Compare with electrical heater system, heat pump
is without electricity leakage risk. It is safe and
green to use the swimming pool heat pump.
10
Titanium Conventional
Material
Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.
Working Principle
The principle of heat pump is to pump the low
grade heat from natural air into swimming pool
water with the help of air heat exchanger.
This is how the HiCOP Swimming pool heat
pump heats up Pool Water.
Model SP-39 SP-62 SP-74 SP-117 SP-156
Power Supply (V/ph/Hz) 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50
Heating Capacity (kw) 39 62 74 117 156
Power Input (kw) 7.5 11.3 14.5 20.1 36
Refrigerant R417a/R410a
Max. curent (A) 25 40 50 75 100
Rated water temp (0C) 28 28 28 28 28
Level against electric shock I | I I I
Water-proof grade IPX4 IPX4 IPX4 IPX4 IPX4
Net Weight (kg) 250 465 622 893 1500
Net size (mm)- (L*W*H) 1200x920x1220 2080x1100x1676 2000x1100x1790 2400x1300x2080 2400x1900x2080
Required water flow rate (m3/h) 15 25 30 45 60
Water Connection (mm) 63 mm 75 mm 75 mm 90 mm 110 mm
Operation temp range (oC) -10-45 -10-45 -10-45 -10-45 -10-45
Noise dB(A) < 60 < 62 < 64 < 68 < 68
Test Condition Ambient temp (DB/WB) : 20 oC/15 o C
Water temp (Iniial Fina:l): 15OC/28 OC
11
10
Touch LCD Display
Equipped with LCD touch
Display, this series of pool
heat pumps provides users
easy control experience and
provides the unit fine
decorations.
Cost Effective
The COP of this series is as
high as 5.3 at working
condition of 24°C/19°C
(DB/WB), which saves you at
least 80% energy compared
with traditional electric
swimming pool heating.
Titanium Coils Exchanger
Patented Two Titanium Coils
Heat Exchanger features
extended work area with
higher efficiency.
Electric Expansion Valve
Smartly adjust the refrigerant
flow rate, the unit are sure to
work with high efficiency at all
time
Ripple Fin Air Exchanger
Heat exchanging surface
extended, heat exchanging
effect is improved and the risk
of frosting is reduced
Swimming Pool
Portable Series
Features
Pressure Protection
With high / low pressure
protection, heat pump are
protected at bad working
condition.
Water Flow Switch
The water flow switches
designed HiCOP are with high
sensitivity feature.
Multiple Model
Contains 9 models ranging
from 4kW to 23kW, users can
make their favorite choice for a
perfect energy saving
swimming.
12
OverviewWith complete range of models from 5kW to 23kW,
Portable Series is widely welcomed in global markets. In
the working process of absorbing free heat from the air
and transferring it to water, this series of heat pumps
ensures constant and stable pool water temperature for
you.
13
Heating Outdoor air temp (DB/WB): 240C/190C, Water temp (in) 260C
The data above is only a reference, specific data please refer to the nameplate on the units.
Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.
Model SPP SPP-5 SPP-8 SPP-11 SPP-17 SPP-23
Heating CapacitykW 5.4 8,2 11,3 17 23
Btu/h 18360 27880 38420 57800 78200
Heating Power Input kW 1 1,53 2,1 3,48 4,1
COP - 5,4 5,36 5,38 4,89 5,61
Running Current A 4,2 7 9,6 6,8 8
Max Current Input A 6.3 9.2 14.3 9 9.5
Power Supply 220V~/50Hz 380V/3N~/50Hz
Compressor Quantity - 1
Compressor Type - Rotary Scroll
Fan Quantity - 1 2
Fan Power Input W 90 120 150 120x2
Fan Rotate Speed RPM 850
Fan Direction - Horizontal
Noise dB(A) 47 51 54 56 56
Water Connection mm 50
Water Flow Volume m3/h 2,2 3 4,5 6 9
Water Pressure Drop (max) kPa 0,4 0,6 1 2 2,8
Net Weight (L/W/H) kg 35 51 57 98 119
Net Dimensions (L/W/H) mm 746 / 290 / 570 956 / 372 / 600 1115 / 470/870 1002 / 455 / 1250
12
1. High COP of 4.0Apply compressors special for heat pump and acquire
the COP of 4.0.
2. Long Service Life
Coil which is around the unit avoids direct contact with
the water and corrosion coused by negaive ion, thus
the service life would be prolonged.
3. Excellent Inner Container
Apply enameled water storage tank with high hardness,
high temperature and high pressure resistance as the
inner container which makes the water in the unit
healthier and safer for use.
4. Thermostatic Expansion Valve
Applying thermostatic expansion valve as the throttling
set makes the unit more adjustable in wide working
temperature range and operate more stably and
efficient.
5. Environmentally Friendly RefrigerantR134a used as the refrigerant in the unit is pollution-free and with good heating performance.
6. Good Looking ScreenThe screen with elegant looking can be set to orange or
blue background.
7. Wireless Control - iPhone
Cell phone can be used as a controller if there is a
relative application installed in it. the most fashionable
Wi-Fi technology applied in the unit ensures you to
check and set the unit whenever and wherever you
want.
8. Intelligent Defrosting
Using electromagnetic valve for defrosting makes the
least heat loss of the unit as there is no fluctuation in
water temperature and this also ensures excellent
performance of the unit.
9. P&T Relief Valve
Apply P&T relief valve, which will automatically switch
on or off depending on the pressure or temperature in
the tank, to ensure the safety of the unit.
Features
All In One
Heat Pump
Overview
HiCOP Domestic Heat Pump water heater with a COP
which is 4 times higher than that of the water heater,
this series of water heater is an environmentally
friendly and new designed product special for
providing domestic hot water.
Enameled water storage tank used as the inner
container of the water heater prevents corrosion and
brings better quality water to the user, the coil which is
fixed outside the water tank also avoids being
corroded and its service life will be increased.
14
Components
Special Compressor
for Heat Pump
Environmentally
Friendly
Refrigerant
Coil arround
Heat Exchanger
Electromagnetic
Valve
Enamel Inner
Container
P&T
Relief Valve
Thermostatic
Expansion
Valve
Touch Screen
Controller
Wireless Control
(optional)
Micro Channel
(optional)
Model All In One AI-80 Al-100 Al-200 Al-300 AO-270
Heating Capacity kW 1 1 1.8 1.8 3.4
Water Tank Capacity L 80 100 200 300 270
Power Input kW 0.27 0.27 0.46 0.46 0.94
Running Current A 1.2 1.2 2.0 2.0 3,97
Power Supply 220V~/50Hz
Compressor Rotary
Rated Outlet Water Temp 0C 55
Air Volume m3/h 220 220 350 350 450
Air Pressure Pa 30 40
Duct Diameter mm 150 150 150 150 -
Noise dB(A) 45 45 45 45 52
Water Inlet/Outlet Size Inch 1/2 1/2 3/4 3/4 3/4
*Auxiliary E-Heater kW 1,5
Net Dimensions mm 520x1215 520x1340 560x1732 640x1880 640 x 1955
Shipping Dimensions mm 710x640x1400 710x640x1525 720x720x1930 720x720x1990 720 / 760 / 2040
Net Weight kg 69 73 112 129 120
Measurement conditions :
Instant heating : Ambient temperature 15oC/13oC, Water inlet 15oC, Water Outlet 45oC
Work range : (1) Ambient temperature is-7-40 oC (2) The max temperature of water tank is 60oC
Operating parameters : The range of the operating water temperatures :
9~60oC The range of the operating water pressures : 0.15~0.7 MPa
Note : HiCOP reserves the right to discontinue, or change at anytime, specifications or designs without notices and without incurring obligations.
15
16
EVI System
The units adopt IVI system combining with high-
efficient heat exchanger, making the units more
stable and energy efficient. because of the
application of these advanced heat pump
technology, the unit are with lower operation cost.
Higher Outlet Water Temperature 800
The outlet water temperature of the units can
reach 800C by circular heating to meet the need
for high temperature, but the energy consumption
is just 20% of boiler.
Safe and Pollution Free
Driven by electricity without danger of
burning and explosion and adopting R134a
eco-friendly refrigerant without pollution to
the environment. thus, the units are safe
and pollution free.
Reduce CO2 Emissions
Heat Pump reduce million of tons of CO2
emissions from boiler.
High Temperature
Heat Pump
OverviewThis series is presented the high water
temperature up to 800C. With the
concept of Green and Eco Energy.
Suitable for industrial, Commercial and
other necessities.
16
Heating condition : outdoor temperature DB/WB 200C/150C; * outlet water 750C, inlet water (return) 700C.
Note : HiCOP reserves the right to discontinue, or change at any time, speci ications or designs without notices and without incurring obligations.
Model HT-14 HT-26 HT-40 HT-54
Power Supply (V/ph/Hz) 380/3/50 380/3/50 380/3/50 380/3/50
Heating Capacity
(kW) 14 26 40 54
(BTU) 47768 88712 136480 184248
* Rated Power Input (kW) 4.6 9.2 14 18
* Water Feed Speed (L/h) 185 370 860 741
* Test Condition * Ambient temp (Dry Buld/Wet Bulb):20OC/15OC, Water temp (in/out): 15OC/80OC
Refrigerant R134A
Refrigerant Weight (g) 4400 4400*2 4400*3 4400*4
compressor
(type) scroll
(number) 1 2 3 4
Fan
(type) Axial flow type with Nylon fan Blade
(discharging) Horizontal
(number) 1 1 2 2
(air flow)(m3/h) 5000 11000 7400*2 7400*2
Evaporator Aluminium / Cu lamellar tube evaporator
Condenser (heat exchanger) Coaxial coil heat exchanger (Copper Tube-in-Steel Tube)
Economizer (heat exchanger) Stainless Steel Plate
Throttling Device Emerson Thermal Expansion Valve
Controller Indoor Digital Controller
Required Water Flow Rate (m3/h) 4 8 12 16
Water Connection G1” G1-1/4” G2” G2”
Required Tank Cubage (t) 3-5 7-10 12-15 15-20
Max. Current (A) 13 25 37,5 49
Noise dB (A) ≤ 64 ≤ 65 ≤ 68 ≤ 68
Level again electric shock | | | |
Water proof IPX4 IPX4 IPX4 IPX4
Max. Water temp (OC) 80 80 80 80
Operation temp. range (OC) -10-45 -10-45 -10-45 -10-45
Net Weight (kg) 270 320 680 680
Net Size-(L*W*H) (mm) 800 x 800 x 1120 1200 x 970 x 1420 2080x1100x1680 2150 x 1135 x 2080
17
18
Water to Water
Heat Pump
OverviewHiCOP Water to Water heat pump absorb
heat (energy) from water source and
transfer it to warm and heat the water, for
domestic hot water and heating.
The unit could be installed in indoors, as
floating support for compressor to reduce
vibration at the most extent and noise
insulation inside the cabinet as well as
noise jacket for compressor.
Saginomiya brand 4-way valve.
Emerson brand expansion valve.
Copeland scroll compressor
Light touch controller. Pressure Gauge.
18
Reliable components used
Tube in tube heat exchanger.
Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.
The ground loop transfers
ground energy to a refrigerant
in the heat pump.
Increasing the pressure
raises the temperature
Heat is transfered to the
heating water
Earth or Water Source
The refrigerant expands
causing it to cool
Heat is transfered to the room by
radiators or underfloor heating /
hot water for bathroom
Working Principle
Model WW-20 WW-40 WW-60 WW-84 WW-120 WW-160 WW-200
Power Supply V/ph/Hz 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50
Heating CapacitykW
BTU
20.5 42 60 84 120 160 200
68240 143296 204720 286593 426500 614160 682594
Rated power input kW 4.6 9.2 13.8 20 30 36 55
Cooling Capacity
kW
BTU
15 30 45 60 90 120 132
51177 102355 153540 204709 319875 460620 450512
Rated Power Input kW 3.6 7.1 10.8 14.3 21.4 28.5 40
Refrigerant R410A
Compressor Type Scroll
Required Hot Water Flow
Rate
m3/h 4 8 12 16 20 32 38
Required Water Source Flow
Rate
m3/h 3.2 6.4 9.6 12.8 24 25.6 30
Water connection G1” G1-1/4” G2” G2” G3” G3” G3”
Noise dB(A) ≤ 42 ≤ 44 ≤ 45 ≤ 45 ≤ 50 ≤ 52 ≤ 54
Max. Current A 13 25 37 49 83 98 116
Max. Water Output Temp. OC 60 60 60 60 60 60 60
Water Source Temp. Range OC 5 ~ 35 5 ~ 35 5 ~ 35 5 ~ 35 5 ~ 35 5 ~ 35 5 ~ 35
Net Weight kg 120 250 500 500 750 920 920
Net Size (L/W/H) mm 790x620x850 700x720x1290 1560x840x1380 1560x840x1380 2400x900x1380 2000x1100x1460 2000x1100x1460
Heating by water Source Temp. (In/Out) : 15 OC / 7OC and Water Temp. (In/Out) : 15OC / 55OC ;
Cooling by Water Source Temp. (In/Out) : 25OC / 30OC and Water Temp. (In/Out) : 12OC / 7OC ;
19
20
Multifunction
Titanium
Heat Pump
Overview
✓ Compact air / water heat pump for outside installation.
✓ With suction gas cooled Copeland scroll compressor.
✓ With extensive alumunium /Cu lamellar tube Evaporator and
Titanium tube in tube condenser.
✓ Axial Fan.
✓ Refrigerant cycle with thermostatic expansion valve, filter, gas-
liquid separator, high and low pressure switches.
✓ With efficient automatic defrosting by hot gas principle.
✓ Electric and terminal box. With control and disturbance signaling.
✓ Heating regulator for mounting to the wall.
✓ Filled with refrigerant R417a
Water connections
✓ Water connections have to be done on site.
✓ Heating and condensate connections of flexible pippes with
external thread (R)
Condensate connections
✓ The drain pipeline is to be made with sufficient incline and
without change of the cross.
✓ The water connections and the drain pipelines must be
protected against frost on site.
✓ Shipon on site
Heat source connections (Air
intake or air outlet)
✓ Air intake from the side.
✓ Air outlet from the side
Electrical Connections
✓ Connection from the bottom to the left or to the right.
Installation
✓ Variable and cost-efficient installation possibilities.
Note : HiCOP reserves the right to discontinue, or change at any time, specifications or design without notices and without incurring obligations.
20
* Heating by ambient temp.(DB/WB): 70C /60C and water temp. (in/out): 400C /450C
* Cooling by ambient temp.(DB/WB): 350C /240C and water temp. (in/out): 120C /70C
* Heating by ambient temp.(DB/WB): 200C /150C and water temp. (in/out): 150C /550C
Note : HiCOP reserves the right to discontinue, or change at any time, specifications or design without notices and without incurring obligations.
21
Model MFT - 20 MFT - 38 MFT - 52
Power supply V/ph/Hz 380/3/50
* Heating Capacity kW 20 38 52
* Rated Power input kW 4.6 9.2 13.8
* Cooling Capacity kW 12.5 25 37
* Rated Power Input kW 4.8 9.5 14
Refrigerant R417A
Max Current (A) 13 25 35
Compressor Scroll
Max. Heating water temp 0C 60
Water-proof grade IPX4
Nett weight Kg 280 580
Nett size mm 900x685x1490 1420x1100x1680 2150x1420x1910
Required Cool water flow rate m3/h 2.5 5 7.5
Required Hot water flow rate m3/h 3 8 12
Water Connection operation G1" G1-1/4" G2"
Temp. Range 0C -55
Noise dB (A) ≤60 ≤62
22
High Energy Saving
No Heat Loss
Features
Overview
A heat pump dryer is a new type of drying
device which transfers heat energy in the air
into refrigerant to heating or drying. It
successfully applies reverse Carnot principle
by using electric energy to start and make
refrigerant constantly accomplish the
thermodynamic cycle process among
evaporator, compressor, condenser and
expansion valve. Heat pump dryer is very
economical, capable of saving the 50% ~ 70%
energy compared with the classical oven dryer.
Dryer
Heat Pump
Closed Cycle Structure
Unaffected by Environment
No Dust Pollution Clean
and Safe
Convenient to Install Easy to
Maintain
High Drying Quality
Good Appearance
22
Working Principle
HiCOP dryer can be used in agriculture product, including fruits, seafoods, medicinal materials, corn, wheat and etc.
Testing Conditions : Outdoor temperature (DB/WB) 200C/150C
Indoor temperature (DB/WB) 600C/300C
▪ Traditional Drying Problem
Large Heat Loss | Easily Influenced by Climate | Bad Drying Environment | High Cost
Note : HICOP reserved the right to discontinue, or change at any time, specifications or design without notice and without incurring obligations.
Model DR-18 DR-36
Operation Temp. Range 0C 0 - 500C 0 - 500C
Drying Temp. Range 0C 30-750C 30-750C
Heating Capacity kW 18 36
Power Input kW 6 12
Current A 11 22
Electric Heater kW 12.00 24.00
Dehumidification Capacity kg/h 25.00 50.00
Air Outlet Mode Slide-blown
Unit Dimension mm 1830*1150*1313 2120*1330*1550
Advised Chamber Size m3 20-30m3 40-50m3
23
14
Split Type
Heat Pump
Overview
Split heat pump water heater is
designed with one indoor unit and one
outdoor unit. The air exchanger set in
the outdoor unit will greatly enlarge the
heat exchanger square and improve the
COP of the unit, then lower the
operation cost.
Application
24
Testing Condition: Ambient temperature 20/150C Water circulated from 15 to 550C
Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.
25
Model STP - 3 STP - 5
Rated Heating Output kW 3.8 5.75
Rated Power Input kW 0.9 1.3
COP W/W 4.18 4.18
Rated Running Current A 3.95 5.98
Max. Running Current A 5.5 7.59
Power Supply V/Ph/Hz 220 ~ 240/1/50
Hot Water Capacity L/h 80 120
Compressor Quantity 1
Compressor Type / Rotary
Fan Quantity / 1
Air Volume m3/h 2400
Air Discharge Type / Horizontal
Water Pressure Drop kPa 30 28
Water Connection Inch 1 1
Noise dB (A) 51 57
Circulation Water Pump / Wil o R S15 / 6
Default Water Temp 0C 55
Suggested Max. Water Temp. 0C 60
Operation Range 0C -7 ~ 45
Condenser / Tube in Shell Heat Exchanger
Evaporator / Φ7mm Finned Heat Exchanger
Defrosting / By 4-way valve
Controller / Multi - Function Controller + LED Display
Refrigerant / R410A
Casing / Environment - Friendly Galvanized Metal
Nett Weight Kg 58 61
Gross Weight Kg 68 71
Nett Dimension (L/W/H) mm 892x342x605
Shipping Dimensions (L/W/H) mm 905x380x755
Spa Water Chiller
Suitable for spa and sauna pools, and for places where special aqueous medium such us sea
water, swimming pool water and thermal spring water is used. Safe and reliable use with strong
corrosion resistance ability.
Patent-Composite Steel Plastic Shell Coil
Heat Exchanger
Application Diagram
Overview
1. Heat Exchanger Inner Core
2. Temperature Sensing Point
3. Metal Connector
4. Steel Cover Plate
5. Waterway Sealing Gasket
6. Plastic Cover Plate
7. Drainage Port
8. Refrigerant Way Sealing Gasket
9. Steel Shell
10.Plastic Shell
11.Heat Insulation Material (PU)
12.Mounting Brecket
26
Features
HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.
Note :
(1) Cooling :Outdoor air temp: 35oC/24oC, Outlet water temp: 5oC, lnput water temp:12oC.
(2)Using in ambient temperature: -5oC ~ 43oC.
High heat exchange efficiency and compact design
High efficient internal thread tubes in heat exchanger.
Heat transfer coefficient is more than twice of traditional
shell and tube heat exchanger.
Skillful seal of refrigerant inlet and outlet to avoid
water leakage
Temperature-resisting material for sealing element, able to
resist high temperature up to 200oC and low temperature
down to - 20oC.
Filling of heat insulation material to reduce heat leakage
Foam materials filled between steel shell and engineering
plastic shell, efficiently reduce heat leakage. No need for
extra thermal insulation on the outer casing.
Independent joint connector, more durable
Metal material for water inlet/outlet, strong and durable.
Available for special water quality
Efficient to resist different degree of acid-base corrosion,
chloride corrosion and sediment scouring.
Model SWC - 7 SWC-14
Rate Cooling Capacity KW 6.9 13.8
BTU/H 23600 47100
Rated Input Power ( Cooling ) KW 2.42 4.8
Rated Input Current ( Cooling ) A 11.0 7.4
Power Supply V/PH/Hz 220/1/50 380/3/50
Compressor Scroll
Heat Exchanger
Hydrophilic aluminum foil fin + internal threaded cooper tube
Titanium heat exchanger
Throttle Control Electronic Expansion Valve
Controller LCD display wired controller
Sound Level dB(A) 52 55
Water Oulet/Water Inlet Inch 1.5" 1.5"
Water Flow Volume m3/h 1.19 2.37
Refrigerant Type R410A
Nett Dimension mm 680/790/820 1445/730/795
Corrosion resistant and long service life, no easy
blockage on waterside
Engineering plastic is with better corrosion
resistance and thus longer service life than metal.
The waterside volume of heat exchanger is more
than twice than plate heat exchanger and thus more
resistant to filth blockage.
27
Mini Tank
Typical chemical composition weight %
Outokumpu EN ASTM Cr Ni Mo N PRE* Rp0.2**
LDX 2101 1.4162 S32101 21.5 1.5 0.3 0.22 26 450*** Lean Duplex
2304 1.4362 S32304 23 4.8 0.3 0.10 26 400 Duplex
2205 1.4462 S32205 22 5.7 3.1 0.17 35 460 Duplex
2507 1.4410 S32750 25 7 4 0.27 43 530 Super Duplex
4507 1.4501 S32760 25.4 6.9 3.8 - 42 530 Super Duplex
4307 1.4307 304L 18.1 8.1 - - 18 200 Austenitic
4404 1.4404 316L 10.1 2.1 - 24 220 Austenitic
4432 1.4432 316L 16.9 10.7 2.6 - 25 220 Austenitic
904L 1.4539 N08904 20 25 4.3 - 34 220 Austenitic
254 SMO 1.4547 S31254 20 18 6.1 0.20 43 300 Super Austenitic
4529 1.4529 N08926 20.5 24.8 6.5 0.20 45 300 Super Austenitic
Material welding of Duplex
✓Good weldability
✓TIG-GTAW, Laser and PAW most common
✓Use filler metal: Avesta LDX 2101® / 22 9 3 NL
✓Nitrogen additions to shielding / backing gas gives positive effect on strength andcorrosion resistance
✓Shielding gas (TIG)
✓Backing gas (TIG)
✓Use back gas also when repair and welding
✓Post weld heat treatment not necessary
✓LDX2101 is suitable for autogenously welding and welding without filler
✓Welding decreases corrosion resistance! Effect less with good backing gas shielding.
Post weld cleaning is recommended!
Ar + 1-3% N2, Ar + 10-30% He + 2% N2, Ar
90% N2 + 10% H2, 95% N2 + 5% H2, N2
R*EP= %Cr + 3.3x%Mo + 16x%N** [MPa] Hot rolled plate, min values at 20oC according to EN 10088
*** Not yet in EN 10088, Rp0.2 according to ASTM A240
28
• Austenitic 18Cr + 8Ni + (2Mo)
• Duplex 22Cr + 1.5 - 5 Ni
✓ Excellent formability and weldability.
✓ Good resistance to local corrosion.
✓ Sensitive to Stress to Corrosion Cracking.
✓ Combination of austenitic & ferritic structure.
✓ Not sensitive to SCC.
✓ Good weldability and machinability.
✓ High mechanical properties.
✓ Low alloy content - price stable.
✓ No Ni - content - price stable.
✓ Not sensitive to SCC.
✓ Limited welding and elongation properties.
Duplex - what's that?
Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.
Normal Capacity TD-300 TD-400 TD-500
Tank Diameter mm 600 650 700
Inner Tank Diameter mm 500 550 600
Tank Height mm 1560 1810 1828
Inner Tank Material Duplex 1.0 mm Duplex 1.5 mm
Heat Insulation High density polyurethane 50 mm
Finishing Outer Skin Bar Silver Painting 0.5 mm
Max. Test Pressure Bar 10
Max Working Pressure 6
Cold Water Inlet G.1"
Hot Water Outlet G.1"
Circulating Hole (red) G.1"
Circulating Hole (blue) G.1"
Sensor Pipe G.1/2"
Drain Water G.3/4"
Mg Anode G.3/4"
Screwed Electric Heater G.1" (3 kw)
Exhaust (up) G.3/4"
• Ferritic 20Cr + (2Mo)
Austenitic
(Nickel-containing)
Duplex Duplex
(Low-nickel)
Ferritic
(Non-nickel)
29
24
Commercial TankPressurized &Non Pressurized
Benefit Product Support
1. High energy efficiency
2. Patented and Safety product
3. Applicable for commercial industries like hotel,
villa, hospital and factory
4. Suitable for heat pump and gas water heater
complimentary.
5. High density insulation (eliminate heat loss)
1. Easy maintenance and Installation
2. Quality manufacturing standart
3. Free technical consultation & design
4. High quality installation
5. Large variety of tanks based on needs
6. Warranty: 5 years for non pressurized tanks, 1
year for pressurized tank
30
ModelHot Water Storage Tank (Pressurized)
1000 Liter 2000 Liter 3000 Liter 4000 Liter 5000 Liter 6000 Liter 7000 Liter 8000 Liter
Tank Material Stainless Steel SUS 304
Working
Pressure (bar)4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8 4 6 8
Shell (mm) 3 3 5 3 4 6 3 4 6 4 5 8 4 6 8 5 6 8 5 8 8 5 8 8
Dome (mm) 3 4 6 4 5 8 4 5 8 4 6 8 5 8 8 6 8 10 6 8 10 6 8 10
Tank Weight
(empty) (kg) 400 500 700 600 800 1100 700 900 1200 900 1200 1500 1100 1500 1700 1400 1700 2000 1600 1900 2100 1700 2000 2200
Tank Weight
(full) (Mt)1.4 1.5 1.7 2.6 2.8 3.1 3.7 3.9 4.2 4.9 5.2 5.5 6.1 6.5 6.7 7.4 7.7 8 8.6 8.9 9.1 9.7 10 10.2
Tank
Diameter
(mm) *
950 1200 1300 1400 1500 1550 1600 1650
Tank Height
(mm) **2000 2400 2900 3200 3500 3800 4100 4300
Back Up
Heater
Thermostat Optional (Heatpump / Gas Heater / Electric Heater)
Inlet
Diameter
(inch)
1.5 2 2 2.5 2.5 3 3.5 4
Outlet
Diameter
(Inch)
1.5 2 2 2.5 2.5 3 3.5 4
Drain
Diameter
(Inch)
1.5 2 2 2 2 2.5 3 3
Outer Skin Zincallume 0.5
Finishing
Outer SkinFined Silver Coated
Heat
InsulationHigh Density Polyurethane 50 mm
Accessories Safety Valve, Pressure Gauge, Temperature Gauge, Air Fan, Magnesium Anode
** Height Total
Model Hot Water Storage Tank (Non Pressurized)
Capacity 1000 Liter 2000 Liter 3000 Liter 4000 Liter 5000 Liter 6000 Liter 7000 Liter 8000 Liter
Tank Material Stainless S teel SUS 304
Shell (mm) 1.2 3 3 3 4 4 5 5
Dome (mm) 1.2 3 3 4 4 5 6 6
Tank Diameter (mm)* 1100 1200 1300 1400 1500 1550 1600 1700
Tank Height (mm)** 1600 2400 2900 3200 3500 3800 4100 4100
Tank Weight (empty) (kg) 300 500 600 800 1000 1300 1500 1600
Tank Weight (full) (Mt) 1.1 2.5 3.6 4.8 6 6.3 8.5 9.6
Back Up Heater Optional (Heatpump / Gas Heater / Electric Heater)
Thermostat Optional
Inlet Diameter (Inch) 0.75 2 2 2.5 2.5 3 3.5 4
Outlet Diameter (Inch) 0.75 2 2 2.5 2.5 3 3.5 4
Valve Diameter 1” 2” (Customize)
Drain Diameter (Inch) 0.75 2 2 2 2 2.5 3 3
Outer Skin Zincallume 0.5
Finishing Outer Skin Fined Silver Coated
Heat Insullation High Density Polyurethane 50 mm
Accessories Water Level Controller (WLC), Sig ht Glass, Tempe rature Gauge, Magnesium Anode, Flo atless Switch
Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.
* Without Jacketing
** Height Total
Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.
* Without Jacketing
31
Gas Water Heater
FeaturesNote : HiCOP reserves the right to discontinue, or change at any time, specifications or
designs without notices and without incurring obligations.
• Classic design with three knobs
• Compact size, easy for installations
• Flame out protection
• Over-heated protection
• Extremely low water pressure start up
Model No. GWH-A6 GWH-A10
Hot water capacity ∆ 250C
(L/min)6 10
Rated Heat Loud (kW) 12 20
Product size (mm) 445x300x120 590x327x180
Power Supply Apair Of # 1Dry Batteries
N.W./G.W.(kg) 4.9/6.1 9.1/11.1
Material of Heat Exchanger Oxygent Free Cooper
Waste Air Exhaust Flue Duct
Digital Display Yes
Ignition Methode Water Controlled Automatic Ignition
Pipe Joint
Gas Inlet G 1/2
Cold Water Inlet G 1/2
Hot Water Inlet G 1/2
Gas PressureNG 2000Pa
LPG 2800Pa
• 20-min timer protection
• Anty-dry burning protection
• High water pressure protection (safety valve)
• With temperature display
• Oxygent free cooper heat exchanger
32
33
Project References
JAKARTA
Hotel Bunga-bunga - Jakarta
❑ 12 Unit Heat Pump HiCOP AI-300
Hotel Grand Novena - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-10
My Place SPA - Jakarta
❑ 4 Unit Heat Pump HiCOP SP-17
Hotel Fave Puri - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-21
Hotel Haris Yello - Jakarta
❑ 5 Unit Heat Pump HiCOP AW-105
Martha Tilaar SPA - Jakarta
❑ 2 Unit Heat Pump HiCOP AI-300
Hotel Posto Dormire - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-37
Hotel NEO Puri - Jakarta
❑ 2 Unit Heat Pump HiCOP AWP-42
❑ 2 Unit SAC Pressure Tank 2000 L
Heaven SPA - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-21
❑ 2 Unit Heat Pump HiCOP SP-17
❑ 2 Unit Heat Pump HICOP MFT-20
Hotel 7 Days - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-21
RS Atma Jaya - Jakarta
❑ 3 Unit Heat Pump HiCOP AW-37
Hotel Park 5 - Jakarta
❑ 3 Unit Heat Pump HiCOP AW-21
RS Hermina - Jakarta
❑ 2 Unit HiCOP Pressure Tank 3500L
Amaris Thamrin City - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-40
Hotel Casa Living - Jakarta
❑ 2 Unit Heat Pump HiCOP AI-300
Hotel Ozone - Jakarta
❑ 3 Unit Heat Pump HiCOP AW-21
❑ 2 Unit HiCOP Pressure Tank 3500 L
Apartment Paviliun - Jakarta
❑ 1 Unit Heat Pump HiCOP AI-200
Hotel Arosa - Jakarta
❑ 3 Unit Heat Pump HiCOP AW-37
Hotel Best Westin - Jakarta
❑ 3 Unit Heat Pump HiCOP SP-17
Universitas Mandiri - Jakarta
❑ 4 Unit HiCOP Pressure Tank 2500 L
RS Fatmawati - Jakarta
❑ 1 Unit Heat Pump HiCOP AW-21
Hotel Shangri la - Jakarta
❑ 2 Unit Heat Pump HiCOP SPP-23
RSUD Tarakan - Jakarta
❑ 2 Unit Heat Pump HiCOP AI-300
Hotel Amaris Slipi - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-21
Hotel Holiday Inn - Jakarta
❑ 3 Unit Heat Pump HiCOP AW-90
Mel's Lodge - Jakarta
❑ 3 Unit Heat Pump HiCOP AO-270
Hotel Genteng Ijo Residence - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-10
❑ 1 Unit HiCOP Pressure Tank 2000 L
Hotel 21 - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-10
❑ 1 Unit HiCOP Pressure Tank 2000 L
Hotel Neo Kebayoran Icon - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-37
Hotel Norwood - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-10
U Residence - Jakarta
❑ 5 Unit Heat Pump HiCOP AI-200
Hotel Royal Olive - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-37
❑ 2 Unit HiCOP Pressure Tank
5000 L
Hotel Gunawaman - Jakarta
❑ 4 Unit Heat Pump HiCOP AW-10
Hotel Intan - Jakarta
❑ 3 Unit Heat Pump HiCOP AW-21
❑ 2 Unit HiCOP Pressure Tank 3000 L
Hotel POP - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-21
Hotel Fortune - Jakarta
❑ 2 Unit Heat Pump HiCOP AW-21
❑ 4 Unit Heat Pump HiCOP SP-39
PT. Arnott's Indonesia
❑ 2 Unit Heat Pump HiCOP HT-58
Kolam Renang Sunter - Jakarta
❑ 1 Unit Heatpump HiCOP SP-62
RS Yarsi - Jakarta
❑ 3 Unit Heat Pump HiCOP AW-37
❑ 4 Unit HiCOP Pressure Tank 3000 L
Hotel Amaris Season City - Jakarta
❑ 2 Unit Heatpump HiCOP AW-21
Hotel Merbabu - Jakarta
❑ 4 unit Heat Pump HiCOP AI-300
TANGERANG
Hotel POP BSD - Tangerang
❑ 2 Unit Heatpump HiCOP AW-35
BANDUNG
Hotel Gracia SPA - Bandung,
❑ 1 Unit Heat Pump HiCOP AW-10
Hotel Shangri la - Bandung
❑ 1 Unit Heat Pump HiCOP AW-21
Hotel Oasis - Bandung
❑ 1 Unit Heat Pump HiCOP AW-10
Setiabudi Regency - Bandung
❑ 1 Unit Heat Pump HiCOP SP-39
Gues House 3S Pasteur - Bandung
❑ 2 Unit Heat Pump HiCOP AI-300
Hotel Resort - Bandung
❑ 2 Unit Heat Pump HiCOP AW-10
Hotel Onoma - Bandung
❑ 2 Unit Heat Pump HiCOP AW-37
Waterboom Panghegar - Bandung
❑ 2 Unit Heat Pump HiCOP SP-17
The Valley Dago - Bandung
❑ 2 Unit Heat Pump HiCOP SP-39
❑ 3 Unit Heat Pump HiCOP AW-37
Hotel NEO - Bandung
❑ 1 Unit Heat Pump HiCOP AW-10
❑ 1 Unit Heat Pump HiCOP AW-21
Hotel Horison - Bandung
❑ 1 Unit Heat Pump HiCOP AW-21
Eiffel SPA - Bandung
❑ 1 Unit Heat Pump HiCOP SPP-17
Hotel House Sangkuriang - Bandung
❑ 1 Unit Heat Pump HiCOP AW-21
Villa Ciwaruga - Bandung
❑ 1 Unit Heat Pump HiCOP AI-300
Hotel Grand Tjokro - Bandung
❑ 1 Unit Heat Pump HiCOP AWP-42
Hotel MAJ Collection - Bandung
❑ 5 Unit Heat Pump HiCOP SP-39
34
Project References
BANDUNG
Hotel Art Deco - Bandung
❑ 8 Unit Heat Pump HiCOP AW-21
Hotel Dafam - Bandung
❑ 3 Unit Heat Pump HiCOP AW-21
Hotel Nandya - Bandung
❑ 2 Unit Heat Pump HiCOP AI-300
Hotel Pool Karapitan - Bandung
❑ 1 Unit Heat Pump HiCOP AW-10
Mekar Wangi Pool - Bandung
❑ 1 Unit Heat Pump HiCOP AW-10
❑ 1 Unit Heat Pump HiCOP SP-17
Hotel Nyland - Bandung
❑ 2 Unit Heat Pump HiCOP AW-21
❑ 2 Unit Heat Pump HiCOP STP-5
❑ 1 Unit HiCOP TD-500
❑ 1 Unit HiCOP TD-300
Hotel Moscato - Lembang
❑ 4 Unit Heat Pump HiCOP AI-300
RS H Saleh Budiman - Bandung
❑ 1 Unit Heat Pump HiCOP AW-21
Hotel Triple 7 - Pajajaran
❑ 1 Unit Heat Pump HiCOP AW-10
Hotel Blackbird- Bandung
❑ 1 Unit Heat Pump HiCOP AW-21
UPI - Bandung
❑ 2 Unit Heat Pump HiCOP SP-69
PT. Afiat Pharmaceutical - Bandung
❑ 1 Unit Heat Pump HiCOP AI-300
The Groove Sport Station - Bandung
❑ 2 Unit Heat Pump HiCOP SP-39
❑ 2 Unit Heat Pump HiCOP SP-17
Ciwidey Valley Resort - Bandung
❑ 4 Unit Heat Pump HiCOP SP-156
❑ 2 Unit Heat Pump HiCOP SPP-23
❑ 1 Unit Heat Pump HiCOP HT-14
Hotel Santika - Bandung
❑ 2 Unit Heat Pump HiCOP AW-50
❑ 2 Unit HiCOP Pressure Tank 4000 L
Hotel POP Pasar Baru - Bandung
❑ 2 Unit Heat Pump HiCOP AW-21
Super Soccer Prestasi - Bandung
❑ 2 Unit Heat Pump HiCOP SP-62
Eiffel Spa - Bandung
❑ 1 Unit Heat Pump HiCOP SPP-17
Hotel Andelir - Bandung
❑ 4 Unit Heat Pump HiCOP AW-10
Hotel House Sangkuriang - Bandung
❑ 4 Unit Heat Pump HiCOP AW-21
RS Halmahera - Bandung
❑ 4 Unit Heat Pump HiCOP AW-10
RS Edelweiss - Bandung
❑ 2 Unit Heat Pump HiCOP AWP-21
SURABAYA
Hotel Swiss Bell Darmo Centrum -
Surabaya
❑ 3 Unit Heat Pump HiCOP AW-37
❑ 2 Unit HiCOP Pressure Tank 5000 L
Hotel Swiss Beli Tunjungan - Surabaya
❑ 2 Unit Heat Pump HiCOP AW-37
Hotel Kokoan - Surabaya
❑ 2 Unit Heat Pump HiCOP AW-21
❑ 2 Unit HiCOP Pressure Tank 2000 L
Apartment Caspian - Surabaya
❑ 461 Unit Heat Pump HiCOP GWH A-6
❑ 78 Unit Heat Pump HiCOP GWH A-10
Hotel Ibis - Surabaya
❑ 2 Unit HiCOP Pressure Tank 4000 L
Hotel Singasari - Surabaya
❑ 1 Unit Heat Pump HiCOP AI-100
Hotel Howard Johnson - Surabaya
2 Unit HiCOP Pressure Tank 2000 L
BALI
Hotel Aloft - Bali
❑ 2 Unit Heat Pump HiCOP AW-30
Hotel Horison - Bali
❑ 1 Unit Heat Pump HiCOP AW-21
Zen SPA - Bali
❑ 1 Unit Heat Pump HiCOP MFT-10
Hotel Fairfield - Bali
❑ 3 Unit Heat Pump HiCOP AW-50
❑ 2 Unit HiCOP Pressure Tank 8000 L
Hotel Sulis - Bali
❑ 3 Unit Heat Pump HiCOP AW-21
Svarga Villa - Bali
❑ 2 Unit Heat Pump HiCOP AI-200
❑ 1 Unit Heat Pump HiCOP AI-300
Nusa Dua Convention Center - Bali
❑ 2 Unit Heat Pump HiCOP AW-42
Hotel Artotel Haniman - Bali
❑ 4 Unit Heat Pump HiCOP AI-300
❑ 2 Unit Heat Pump HiCOP AW-10
❑ 4 Unit HiCOP Pressure Tank 1000 L
Hotel Ungasan Cliftop Resort - Bali
❑ 2 Unit Heat Pump HiCOP AI-200
Hotel Rennaisance - Bali
❑ 2 Unit Heat Pump HiCOP AW-90
❑ 2 Unit HiCOP Pressure Tank 5500 L
RS Kasih Ibu - Bali
❑ 2 Unit Heat Pump HiCOP AW-37
Hotel Promenade - Bali
❑ 2 Unit Heat Pump HiCOP AW-37
Villa Kharisma - Bali
❑ 4 Unit Heat Pump HiCOP AI-300
Hotel Amaris Teuku Umar - Bali
❑ 2 Unit Heat Pump HiCOP AW-21
❑ 2 Unit HiCOP Pressure Tank
2000 L
Hotel Puri Artha - Bali
❑ 3 Unit Heat Pump HiCOP AI-300
Hotel Premier Prada - Bali
❑ 2 Unit Heat Pump HiCOP AW-42
❑ 2 Unit Heat Pump HiCOP AW-37
Hotel Bali Mandira - Bali
❑ 2 Unit Heat Pump HiCOP AW-21
Hotel The Kirana Canggu - Bali
❑ 3 Unit Heat Pump HiCOP AW-21
Hotel Kuta Puri Bungalow - Bali
❑ 2 Unit Heat Pump HiCOP AI-200
Hotel Grand Inna Kuta - Bali
❑ 2 Unit Heat Pump HiCOP AW-37
❑ 1 Unit Heat Pump HiCOP AW-72
Villa Aster - Bali
❑ 1 Unit Heat Pump HiCOP SPP-11
❑ 2 Unit HiCOP Pressure Tank 2000 L
Hotel Gobleg - Bali
❑ 1 Unit Heat Pump HiCOP SP-74
Hotel Mulia - Bali
❑ 3 Unit Heat Pump HiCOP SP-39
Hotel Ossotel - Bali
❑ 2 Unit Heat Pump HiCOP AW-39
Dekkande & SPA - Bali
❑ 4 Unit Heat Pump HiCOP AI-300
35
Project References
BALI
Hotel Petitenget - Bali
❑ 6 Unit Heat Pump HiCOP AI-300
Villa Ultimo - Bali
❑ 1 Unit Heat Pump HiCOP SP-20
❑ 1 Unit Heat Pump HiCOP SP-17
RS Provinsi Bali
❑ 2 Unit Heat Pump HiCOP AW-37
❑ 2 Unit HiCOP Pressure Tank 5000 L
Hotel Ibis Seminyak - Bali
❑ 3 Unit Heat Pump HiCOP AW-37
Villa The Kama - Bali
❑ 3 Unit Heat Pump HiCOP AI-300
Villa Canggu - Bali
❑ 1 Unit Heat Pump HiCOP SPP-11
❑ 1 Unit Heat Pump HiCOP SWC-7
Villa Wanagiri - Bali
❑ 1 Unit Heat Pump HiCOP SP-39
❑ 4 Unit Heat Pump HiCOP SP-74
Villa Batur - Bali
❑ 1 Unit Heat Pump HiCOP SPP-8
Hotel Shaggrila - Bali
❑ 4 Unit Heat Pump HiCOP AI-200
Villa batu Bolong - Bali
❑ 2 Unit Heat Pump HiCOP SWC-7
Villa Amrita - Bali
❑ 3 Unit Heat Pump HiCOP AI-300
Hotel Kuta - Bali
❑ 1 Unit Heat Pump HiCOP AI-100
❑ 2 Unit Heat Pump HiCOP AI-200
Hotel Wana Segara - Bali
❑ 4 Unit Heat Pump HiCOP AW-21
Hotel Pengosekan - Bali
❑ 8 Unit Heat Pump HiCOP AI-300
Villa Kedungu - Bali
❑ 2 Unit Heat Pump HiCOP-AI 300
❑ 1 Unit Heat Pump HiCOP AI-200
Hotel Capital - Bali
❑ 2 Unit Heat Pump HiCOP AW-10
Hotel The Royal Seminyak - Bali
❑ 1 Unit Heat Pump HiCOP AW-42
RS Puri Bunda - Bali
❑ 3 Unit Heat Pump HiCOP AWP-35
❑ 2 Unit HiCOP Pressure Tank 3000 L
Green Villa - Bali
❑ 2 Unit Heat Pump HiCOP STP-7
❑ 2 Unit HiCOP Duplex Tank TD-500
Amarin Villa - Bali
❑ 7 Unit Heat Pump HiCOP AI-300
Hotel The Hava - Bali
❑ 2 Unit HiCOP Pressure Tank 3500 L
Hotel Kristana - Bali
❑ 2 Unit Heat Pump HiCOP AW-15
❑ 2 Unit SAC Pressure Tank 2000 L
BANTEN
Mess UPI - Serang
❑ 3 Unit Heat Pump HiCOP AW-10
DEPOK
Universitas Islam Internasional
Indonesia - Depok
❑ 4 Unit Heat Pump HiCOP AWP-42
❑ 4 Unit HiCOP Pressure Tank 2000 L
BEKASI
Hotel Horison - Bekasi
❑ 1 Unit Heat Pump HiCOP AW-21
Hotel Aston Royal - Bekasi
❑ 2 Unit Heatpump HiCOP AW-21
RSUD Cibitung
❑ 3 Unit Heat Pump HiCOP AW-10
❑ 2 Unit HiCOP Pressure Tank 2000 L
BOGOR
Hotel Sahid Eminence - Ciloto Puncak
❑ 4 Unit Heat Pump HiCOP AW-62
❑ 3 Unit Heat Pump HiCOP SP-62
❑ 2 Unit Heat Pump HiCOP AWP-42
❑ 2 Unit HiCOP Pressure Tank 10.000 L
❑ 1 Unit HiCOP Pressure Tank 5000 L
Hotel Ibis - Bogor
❑ 3 Unit Heat Pump HiCOP AW-42
Hotel Mirah - Bogor
❑ 1 Unit Heat Pump HiCOP AW-21
Hotel Pesona Alam (Harris) Cisarua -
Bogor
❑ 2 Unit Heat Pump HiCOP AW-10
❑ 2 Unit Heat Pump HiCOP AW-20
❑ 1 Unit Heat Pump HiCOP AW-21
RSUD Bogor
❑ 2 Unit Heat Pump HiCOP AW-37
Restaurant Bebek Tepi Sawah - Ciloto
Puncak
❑ 1 Unit Heat Pump HiCOP AW-21
❑ 1 Unit HiCOP Pressure Tank
2000 L
Wisma BPJS - Puncak
❑ 8 Unit Heat Pump HiCOP AI-300
Hotel Fave - Bogor
❑ 2 Unit Heat Pump HiCOP AW-37
Hotel Green Forest - Bogor
❑ 2 Unit Heat Pump HiCOP AW-42
❑ 2 Unit HiCOP Pressure Tank 3000 L
Villa Lody - Cisarua
❑ 1 Unit Heat Pump HiCOP SPP-11
Hotel Salak - Bogor
❑ 3 Unit Heat Pump HiCOP AW-37
❑ 2 Unit HiCOP Pressure Tank
3000 L
KARAWANG
Hotel Britz - Karawang
❑ 2 Unit Heat Pump HiCOP AW-21
Front One Boutique - Karawang
❑ 3 Unit Heat Pump HiCOP AI-300
CIKARANG
Hotel Santika - Cikarang
❑ 2 Unit Heat Pump HiCOP AW-21
RS Omni - Cikarang
❑ 3 Unit Heat Pump HiCOP AW-42
❑ 2 Unit HiCOP Pressure Tank 5000 L
CIAMIS
RSUD Ciamis
❑ 1 Unit Heat Pump HiCOP STP-7
❑ 2 Unit Heat Pump HiCOP AW-42
GARUT
Villa Ranca Bango - Garut
❑ 1 Unit Heat Pump HiCOP AW-10
RPH Farm - Garut
❑ 2 Unit Heat Pump HiCOP HT-14
36
Project References
CIREBON
Hotel Pemuda - Cirebon
❑ 1 Unit Heat Pump HiCOP AW-21
Hotel Sultan Raja - Cirebon
❑ 2 Unit Heatpump HiCOP AW-35
SUKABUMI
Hotel Lido - Sukabumi
❑ 2 Unit Heat Pump HiCOP AW-30
❑ 1 Unit HiCOP Pressure Tank 2000 L
PURWAKARTA
Hotel Pesanggrahan - Jatiluhur
❑ 2 Unit Heat Pump HiCOP AWP-21
❑ 2 Unit HiCOP Pressure Tank 2000 L
TASIKMALAYA
Hotel Fave - Tasikmalaya
❑ 2 Unit Heat Pump HiCOP AW-21
BELITUNG
Hotel Bw Inn - Belitung
❑ 2 Unit Heat Pump HiCOP AW-42
Hotel Bw Suites - Belitung
❑ 2 Unit Heat Pump HiCOP AW-42
Hotel Swiss Bell - Belitung
❑ 2 Unit Heat Pump HiCOP AW-21
Hotel Aston - Belitung
❑ 2 Unit Heat Pump HiCOP AW-42
Hotel Max One - Belitung
❑ 2 Unit Heat Pump HiCOP AW-21
SUMEDANG
Wisma Kartika Astri - Jatinangor
❑ 2 Unit Heat Pump HiCOP AW-21
MOJOKERTO
Hotel Ayola - Mojokerto
❑ 2 Unit Heat Pump HiCOP AW-37
❑ 2 Unit Pressure Tank 3000 L
Mess PT Sengdam
❑ 1 Unit Heat Pump HiCOP AW-10
❑ 1 Unit SAC Pressure Tank 1000 L
KEBUMEN
Hotel Maxsolute - Kebumen
❑ 7 Unit Heat Pump HiCOP AI-300
RSUP Prembun - Kebumen
❑ 1 Unit Heat Pump HiCOP AW-10
❑ 1 Unit HiCOP Pressure Tank 1000 L
PANGANDARAN
RS H.S Budiman - Pangandaran
❑ 1 Unit Heat Pump HiCOP AW-21
MAJENANG
Hotel Borobudur - Majenang
❑ 1 Unit Heat Pump HiCOP AI-300
SEMARANG
Hotel Wibowo - Semarang
❑ 1 Unit Heat Pump HiCOP AI-300
SOLO
Hotel Sala View - Solo
❑ 2 Unit Heat Pump HiCOP AW-21
Hotel Harris & POP - Solo
❑ 2 Unit HiCOP Pressure Tank 1500 L
❑ 2 Unit HiCOP Pressure Tank 3500 L
YOGYAKARTA
Hotel Grand Kesya - Yogyakarta
❑ 3 Unit Heat Pump HiCOP AW-21
Hotel Premier Inn - Yogyakarta
❑ 2 Unit Heat Pump HiCOP AW-37
Hotel Amartya - Yogyakarta
❑ 2 Unit Heat Pump HiCOP AW-37
Hotel Amaris - Yogyakarta
❑ 2 Unit Heat Pump HiCOP AW-37
Hotel NEO - Yogyakarta
❑ 2 Unit Heat Pump HiCOP AW-42
Hotel Mercure Phoenix - Yogyakarta
❑ 2 Unit Heat Pump HiCOP AW-42
❑ 2 Unit HiCOP Pressure Tank 1500 L
Hotel Aveon - Yogyakarta
❑ 2 Unit Heat Pump HiCOP AW-15
2 Unit HiCOP Pressure Tank 1500 L
SIDOARJO
Hotel Aston Kahuripan - Sidoarjo
❑ 3 Unit Heat Pump HiCOP AW-30
❑ 2 Unit HiCOP Pressure Tank 3000 L
BANYUWANGI
Hotel El - Banyuwangi
❑ 4 Unit Heat Pump HiCOP AW-21
❑ 4 Unit HiCOP Pressure Tank 2000 L
Hotel Illira - Bayuwangi
❑ 1 Unit Heat Pump HiCOP AO-270
Hotel Exa - Banyuwangi
❑ 1 Unit Heat Pump HiCOP AO-270
Hotel Kokoon - Banyuwangi
❑ 2 Unit HiCOP Pressure Tank 5000 L
GRESIK
Hotel @HOM - Gresik
❑ 2 Unit Heat Pump HiCOP AWP-21
❑ 2 Unit HiCOP Pressure Tank 1000 L
Hotel Santika - Gresik
❑ 2 Unit HiCOP Pressure Tank 2000 L
BLITAR
Hotel Puri Perdana - Blitar
❑ 1 Unit Heat Pump HiCOP AI-100
BOJONEGORO
Hotel Aston - Bojonegoro
❑ 3 Unit Heat Pump HiCOP AW-37
JEMBER
Hotel Dafam Lotus - Jember
❑ 2 Unit Heat Pump HiCOP AW-30
❑ 2 Unit HiCOP Pressure Tank 2000 L
Hotel Meotel - Jember
❑ 2 Unit Heat Pump AW-30
❑ 2 Unit HiCOP Pressure Tank 2500 L
LAMONGAN
Hotel Hobet - Lamongan
❑ 1 Unit Heat Pump HiCOP AI-100
37
Project References
MALANG
Hote Fave - Malang
❑ 2 Unit Heat Pump HiCOP AW-41
The Alpines - Malang
❑ 2 Unit Heat Pump HiCOP AW-37
❑ 2 Unit HiCOP Pressure Tank 4000 L
Hotel Whiz - Malang
❑ 2 Unit Heat Pump HiCOP AW-37
❑ 2 Unit HiCOP Pressure Tank 3000 L
PASURUAN
Hotel Horison - Pasuruan
❑ 2 Unit Heat Pump HiCOP AW-37
Hotel Baobab Safari - Prigen
❑ 3 Unit Heat Pump HiCOP AW-21
❑ 2 Unit SAC Pressure Tank 2000 L
MEDAN
Hotel Laberzza - Medan
❑ 2 Unit Heat Pump HiCOP AWP-35
❑ 2 Unit HiCOP Pressure Tank 3000 L
KALIMANTAN SELATAN
BUMA Site Sungai Danau Jaya -
Kalimantan Selatan
❑ 2 Unit Heat Pump HiCOP AWP-21
❑ 1 Unit HiCOP Pressure Tank 1500 L
RSUD Ulin - Banjarmasin
❑ 4 Unit Heat Pump HiCOP AW-10
KALIMANTAN BARAT
Hotel Swiss Bell Inn - Singkawang
❑ 3 Unit Heat Pump HiCOP AW-37
❑ 2 Unit HiCOP Pressure Tank 5000 L
Hotel Tapaz Harris - Pontianak
❑ 2 Unit Heat Pump HiCOP AW-21
❑ 2 Unit HiCOP Pressure Tank 3000 L
Hotel Premier Inn - Pontianak
❑ 2 Unit Heat Pump HiCOP AW-37
KALIMANTAN TIMUR
Hotel Swiss bell - Balikpapan
❑ 2 Unit Heat Pump HiCOP AWP-21
Hotel Quest - Balikpapan
❑ 2 Unit Heat Pump HiCOP AW-21
Apartment Pertamina - Balikpapan
❑ 299 Unit Heat Pump HiCOP AI-100
Hotel Four Point - Balikpapan
❑ 3 Unit Heat Pump HiCOP Double Wall
AW-39
❑ 3 Unit SAC Pressure Tank 2000 L
BUMA Site LATI - Kalimantan Timur
❑ 7 Unit Heat Pump HiCOP AWP-21
❑ 5 Unit HiCOP Pressure Tank 1500 L
❑ 2 Unit HiCOP Pressure Tank 1000 L
BUMA Site Indonesia Pratama -
Kalimantan Timur
❑ 6 Unit Heat Pump HiCOP AWP-21
❑ 4 Unit HiCOP Pressure Tank 1500 L
❑ 2 Unit HiCOP Pressure Tank 1000 L
BUMA Site Binungan - Kalimantan
Timur
❑ 1 Unit Heat Pump HiCOP AWP-21
❑ 1 Unit HiCOP Pressure Tank 1500 L
RS Samarinda
❑ 1 Unit Heatpump HiCOP AW-21
BUMA Site LATI Tahap 2 - Kalimantan
Timur
❑ 4 Unit Heatpump HiCOP AWP-21
❑ 4 Unit HiCOP Pressure Tank 1500 L
KALIMANTAN TENGAH
Hotel Mercure Pangkalan Bun -
Kalimantan Tengah
❑ 2 Unit Heat Pump HiCOP AW-33
❑ 10 Unit HiCOP Duplex Tank TD-500
BUKIT TINGGI
Hotel Santika - Bukit Tinggi
❑ 2 Unit Heat Pump HiCOP AW-30
❑ 2 Unit HiCOP Pressure Tank 2500 L
LAMPUNG
Hotel Radison - Lampung
❑ 4 Unit Heat Pump HiCOP AW-37
❑ 2 Unit HiCOP Pressure Tank 7000 L
Hotel Aston - Lampung
❑ 2 Unit Heat Pump HiCOP AW-21
Hotel Urban - Lampung
❑ 2 Unit Heat Pump HiCOP AW-10
JAMBI
Hotel Swiss Bell - Jambi
❑ 3 Unit Heat Pump HiCOP AW-21
❑ 4 Unit HiCOP Pressure Tank 1000 L
LOMBOK
Villa Selong Selo - Lombok
❑ 11 Unit Heat Pump HiCOP STP-3
❑ 1 Unit Heat Pump HiCOP SPP-8
❑ 1 Unit Heat Pump HiCOP SPP-11
❑ 1 Unit Heat Pump HiCOP ST-300
Hotel Sundancer - Lombok
❑ 2 Unit Heat Pump HiCOP MFT-20
MAKASSAR
RS Tadjudin - Makassar
❑ 2 Unit Heat Pump HiCOP AW-30
❑ 2 Unit HiCOP Pressure Tank 1000 L
Hotel Amaris Pettarani - Makassar
❑ 2 Unit Heat Pump HiCOP AW-37
Hotel Amaris Hertasning - Makassar
❑ 1 Unit Heat Pump HiCOP AW-21
Hotel Kartijasa - Makassar
❑ 2 Unit Heat Pump HiCOP SPP-23
MANADO
Hotel Boulevard - Manado
❑ 2 Unit Heat Pump HiCOP AW-10
NUSA TENGGARA TIMUR
Hotel Simphony Alor - Nusa Tenggara
Timur
❑ 8 Unit Heat Pump HiCOP AI-300
PALU
Hotel Sultan Raja - Palu
❑ 3 Unit Heat Pump HiCOP AI-200
PAPUA
Hotel M Boutique - Sorong Papua
❑ 1 Unit Heat Pump HiCOP SP-39
Kapal Carolia - Sorong Papua
❑ 1 Unit Heat Pump HiCOP AO-270
Hote M Express - Sorong Papua
❑ 1 Unit Heat Pump HiCOP AW-10
Project References
Art Deco Luxury - Bandung Hotel BW Inn - Belitung RS Bali Mandara
Pt. Arnotts - Bekasi Hotel Swiss Bell - Singkawang Hotel Artotel Haniman Ubud - Bali
Hotel Grand Forest - Bogor Hotel Pasar Baru Square - BandungHotel Aston - Jakarta
Rsud Cibitung - Bekasi Hotel Grand Inna Kuta - Bali
Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.
38
Project References
Holiday Express Matraman -Jakarta RS Kasih Ibu - Bali
Hotel Sulis - BaliAria Graha Pool - Bandung Puri Artha Ubud - Bali
Swimming Pool Upi -Bandung
Hotel Nite & Day - Surabaya Ciwidey Valley Resort - Bandung
Hotel Aston -Bojonegoro Sahid eminence Puncak Ciloto - Cianjur
Note : HiCOP reserves the right to discontinue, or change at any time, specifications or designs without notices and without incurring obligations.
39
Hotel Radisson - Lampung
COMM/SPI/JUL/2019
Jakarta(021) 5365 0265
Tangerang(021) 5471 726
Bandung(022) 604 6654
Surabaya(031) 752 0649
Bali(0361) 238 750
Copyright 2019