22
HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Embed Size (px)

Citation preview

Page 1: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

HF Series Compressed Air FiltersFlows from 20 to 21,250 scfm (34 to 36.119 m3/h)

Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Page 2: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

The Objective

Quality & reliability

Energy Savings

Product Communication

HF SERIES FILTERS

Page 3: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Hankison Quality is Built into Every Housing

Epoxy coated interior and exterior

Threaded discharge connection

Bayonet head to bowl connection

up to 170 scfm (289 m3/h)

Thermoset polyurethane liquid level indicator

Every housing tested to a 5:1 factor of safety

HF SERIES FILTERS

Page 4: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Hankison Quality is Built into Every Filter Element

All stainless steel inner and outer cores

Complete seam welded cores having a burst pressure of 65 psid (4.5 bar)

Coated foam sleeves providing protection against chemical attacks

100% silicone free

HF SERIES FILTERS

Page 5: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Complete Filter Offering

Seven grades of filtration allow systems to be precisely customized

Each element grade is tested to

international standards

HF SERIES FILTERS

Page 6: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Grade 11 - Bulk Liquid Separator

A labyrinth style flow path removes liquid

water from the air stream by forcing abrupt

directional changes

Liquid water impinges on the walls of the

internal cores while the air stream flows

easily through the labyrinth, providing

minimal pressure losses

Efficient to 5% of rated flow

Removes up to 30,000 ppm liquid

contamination at efficiencies greater

than 90%

HF SERIES FILTERS

Page 7: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Grade 9 - Separator/Filter

99% efficient at removing up to 25,000 ppm

liquid water from an air stream

In-depth coalescing bed captures solid and

liquid contaminates 3 micron in size

and larger

HF SERIES FILTERS

Page 8: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Grade 7 - Air Line Filter

Coarse coalescing filter capable of providing

ISO 8573.1 class 2 solid and class 3 oil

content air

Captures and removes particles 1.0 micron

and larger in size

Remaining oil content as low as 1.0 mg/m3

Extends life of fine coalescing Filters

HF SERIES FILTERS

Page 9: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Grade 6 - Desiccant Afterfilter

Designed to remove solid particles down to

1.0 micron in size in a dry air flow

Long life afterfilter for heatless

desiccant dryers

Outside/in flow, extends the usable life of

the filter

HF SERIES FILTERS

Page 10: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Grade 5 - High Efficiency Coalescing Oil Removal Filter

Capable of providing ISO 8573.1 class 1

Solid and Class 1 oil content air quality

Captures 99.99+% of all oil aerosols

Reduces oil aerosol content to 0.008 ppm

(0.01 mg/m3)

HF SERIES FILTERS

Page 11: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Grade 3 - Maximum Efficiency Coalescing, Oil Removal Filter

Capable of providing air quality greater than

ISO 8573.1 class 1 solids and oil content

air quality

Captures 99.999+% of all oil aerosols

Reduces oil aerosol content to 0.0008 ppm

(0.001 mg/m3)

Best suited to critical applications

HF SERIES FILTERS

Page 12: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Grade 1 - Oil Vapor Removal Filter

Capable of providing ISO 8573.1 class 1

solid and oil content air quality

Activated carbon adsorption filter

Contains 2x more carbon than supplied by

industrial activated carbon filters

Reduces oil aerosol content (as a vapor)

to 0.003 ppm

HF SERIES FILTERS

Page 13: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Save Energy with HF Series Filters

Filter housing provides large flow paths

which minimizes pressure losses

The seven element grades allow for system

customization

HF SERIES FILTERS

Page 14: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Elements Designed to Extend Life and Reduce Pressure Losses

Large 45% open area stainless steel cores

provide even air flow through media at

minimal pressure losses

Filter media with over 96% void volume,

lowers pressure losses while matrix blended

media increases capture efficiency

Thick filter bed extends useable life without

adding pressure losses

HF SERIES FILTERS

Page 15: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Reliable Differential Pressure Gauges & Monitor Save Energy

Three available methods of Differential

pressure indication

Electronic intelligence of the Filter Monitor

Face Gauge

Slide Indicator

Changing the filter elements at the proper

time saves energy and protects the

compressed air system

HF SERIES FILTERS

Page 16: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Saving Energy by Replacing Filter Elements

Reduce energy losses by knowing when its cost effective to replace the filter elements

Differential pressure gauges determine the end of an element’s life. Further contaminant loading beyond this point greatly increases system pressure losses

Saves money and greatly minimize pressure losses in systems by replacing the elements at the end of their efficient life

Filter monitor calculates the point of maximum element efficiency. Loading beyond this point increases pressure to the end of the element’s life.

HF SERIES FILTERS

Page 17: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

The Filter Monitor Evaluates:

Differential Pressure

Time based

Filter performance

HF SERIES FILTERS

Page 18: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Differential Pressure and Time-Based Indications of Element Replacement

Limits False Maximum Pressure Warnings

Provides a count down of days starting at 60

HF SERIES FILTERS

Page 19: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Filter Performance Indication of Element Replacement

Calculates the moment of optimal

element replacement

Provides a 60 day notice before reaching

the replacement point

Monitor mathematically graphs the daily

average differential pressure

Monitor compares the calculated graph to a

known performance graph for each filter to

determine the optimum point of

element replacement

HF SERIES FILTERS

Page 20: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Communicating with the Filter Monitor

All programming equipment is onboard

Uses (3) standard AA batteries for

simple maintenance

HF SERIES FILTERS

Page 21: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Filter Monitor Communication with the User

Provides instantaneous differential

pressure values

Provides daily average differential

pressure values

Provides a 60 day warning of impending

element replacement

HF SERIES FILTERS

Page 22: HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to 36.119 m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)

Remote Alarm Capabilities

RJ11 connection on the monitor can send an alarm signal to the relay box as far as 100 feet away

The relay box provides dry alarm contacts to indicate the alarm mode of the Filter Monitor and an electronic demand drain

The relay box powers both the Filter Monitor and the electric demand drain

HF SERIES FILTERS