DESCRIPTION
Heterogeneous Compute Platforms : Data management. Dan Tsafrir May 2013, ICRI-CI Retreat . Data sharing – the problem. Sharing data between heterogeneous devices Oftentimes c umbersome & device-specific In OS, apps, or both Programmers need to address questions like - PowerPoint PPT Presentation
Citation preview
Data Sharing 1
Heterogeneous Compute Platforms:Data management
Dan TsafrirMay 2013, ICRI-CI Retreat
May 2013, ICRI-CI
Data Sharing 2
Data sharing – the problem• Sharing data between heterogeneous devices
– Oftentimes cumbersome & device-specific– In OS, apps, or both
• Programmers need to address questions like– Can the device work directly on app memory?
Or must it have its own copy of the data?
– Can the device deal with app virtual addresses?Or must the memory be mapped in some other way?
– Should the memory be pinned before passing it to the device? Or can the device withstand I/O page faults Thereby allowing memory overcommitment?
May 2013, ICRI-CI
Data Sharing 3
Data sharing – goal• Big goal
– Data sharing between heterogeneous PEs should "just work”– HW/SW interfaces should allow to keep app programmers mostly
ignorant of details– Need to develop interfaces & runtime layer that
• Abstract away details of each device,• Present to apps a simplified, efficient programming model
• Concrete goal– Focusing on MMU and IOMMU
May 2013, ICRI-CI
Data Sharing 4
Unifying MMU and IOMMU spaces
Ilya Lesokhin Muli Ben-Yehuda Assaf Schuster Dan Tsafrir
May 2013, ICRI-CI
Data Sharing 5
IOMMU in a nutshell• IOMMU vs. MMU
– IOMMU serves I/O devices that perform DMAs
– Like MMU serves processes that access virtual memory
• But– No I/O page faults (IOPFs)– If memory isn’t there => crash
May 2013, ICRI-CI
Data Sharing 6
No IOPFs – consequences• IOMMU management crippled compared to MMU
– Virtual-memory must be pre-allocated & pinned to physical-memory• Can’t do memory overcommitment
– Consider a set of uncooperative VMs with assigned NICs (SR-IOV)– Must pin their entire memory images!
• Kernel’s MMU & IOMMU management subsystems– Developed separately & used differently
• Causes numerous headaches and performance penalties– E.g., can’t use apps virtual memory space to do I/O
• Thus, to be able to unify (and get rid of above drawbacks)– Must have IOPFs
May 2013, ICRI-CI
Data Sharing 7
IOPFs support – current state of affairs • Recently defined industry spec for supporting IOPFs:
– In “PRI” (Page Request Interface)– Part of the PCI-SIG ATS (Address Translation Services) specification
• Bleeding edge I/O devices do (experimentally) support IOPFs– We are working on such experimental NICs
May 2013, ICRI-CI
Data Sharing 8
Research• Status
– Have a working environment– Handling send-IOPFs (currently NIC drops receive-IOPFs)– Measured IOPF handling (breakdown to HW and SW components)
• Next steps– Attempt to reduce overhead– Develop a strategy to handle receive-IOPFs (10 Gb/sec => 1.25 MB/ms)– Characterizing IOPFs
• How often? Performance penalty? Dropped packets?– Show I/O memory space overcommitment is possible & advantageous
• Longer term– Unify process & I/O address spaces
• Processes use their VA buffers, I/O subsystem works directly on them– Does the PRI spec make sense? Optimal? Could be improved? How?
May 2013, ICRI-CI
Data Sharing 9
Rethink the IOMMU
Moshe Malka Nadav Amit Dan Tsafrir
May 2013, ICRI-CI
Data Sharing 10
IOMMU architected similarly to MMU
May 2013, ICRI-CI
|------------------------------------------- virtual address ------------------------------------|
• Has IOTLB• Upon IOTLB miss,
=> HW walks the table
CR3
Data Sharing 11
Does this make sense?
May 2013, ICRI-CI
• We submit that it does not…• Specifically, it seems that
– Since NICs work with rings, IOTLBaccesses are completely predictable(more important than TLB becausepage-tables are un-cached)
– Since NICs map each DMA descriptorjust before using it, and un-maps itjust after, no needfor a page-tablehierarchy
– Performance can begreatly improved ifredesigning the IOMMUto take advantage of the above
Data Sharing 12
Research• Status
– Working hard towards proving all claims from previous slide– Environment: KVM/QEMU setup (10Gb/s NICs) logs all IOMMU accesses
• Future– Not just NICs (have reason to believe other I/O devices too)– Reducing overheads for virtualization (vIOMMU)– What would be the impact of unifying I/O and process spaces?
(previous project)
May 2013, ICRI-CI