Aim of study
The HER vacuum level as seen by the distributed ion pumps (VDIPs) was studied in combination with the luminosity.
This was done to see, if there are any vacuum leaks/break downs that lead to beam losses.
Definitions
Beam loss:
lumits>5000 & 0.9*lumits> lumits+1 & lumi of either ts+1, +2 or +3<1000)
Vacuum activities
vacuumts>vacuumts-4 +3nT for 2 consecutive ts
vacuumts>vacuumav +4nT for 2 consecutive ts
For both quantities there are independent searches.
Results
There were 75 vacuum activities: 13 lead to a beam loss 16 lead to (small) lumi dips 46 had no effect
Results of vacuum activities during constant luminosity
22 vacuum activities during stable luminosity 8 lead to a beam loss 8 lead to a (small) lumi dip 6 had no effect
PR10 9052PR06 9132 PR12 6162
Results of vacuum activities during increasing luminosity (filling)
47 vacuum activities during increasing luminosity 4 lead to a beam loss 4 lead to a (small) lumi dip 39 had no effect
PR06 9132PR02 6082 PR02 9132
Results of vacuum activities during decreasing luminosity (coast down)
6 vacuum activities during decreasing luminosity 1 lead to a beam loss 4 lead to a (small) lumi dip 1 had no effect
PR02 6042 PR12 9132 PR12 6082
JULY 1-11
There were 27 vacuum activities: lead to a beam loss lead to (small) lumi dips had no effect
JULY 1-11
1 vacuum activities during decreasing luminosity 1 had no effect
21 vacuum activities during increasing luminosity 4 lead to a beam loss 5 lead to a (small) lumi dip 12 had no effect
There were 5 vacuum activities during stable luminosity: 1 lead to a beam loss 1 lead to (small) lumi dips 3 had no effect