6
 IPS CARBON STEEL PIPE – HOLE CUT PRODUCTS  VICTAULIC   ®  IS AN ISO 90 01 CERTIFIE D COM PANY   ® REGISTERE D TRADEMA RK OF VICTAU LIC © COPYRIGHT 20 05 VICTAULIC – PRINTED IN U .S.A. – SKU #WC AS-6CJJCL 1480 REV H  11.02  United S tat es • Phone: 1-800-PICK-VIC (1-800-742- 5842) • Fa x: 610-250-8817 • e-mail: pick vic@victa ulic.com Cana da • Phone: 905-884-7444 • Fax : 905-884-9774 • e-mail: vicca nada @victaulic. com Europe • Phone: 32-9-381- 1500 • Fax: 32-9-380-4438 • e-mail: [email protected] UK • Phone: 44(0)1438741100 • Fax : 44(0)1438313883 • e-mail: vice uro@victa ulic.be Centra l and Sout h America Phone: 610-559-3300 • Fax : 610-559-3608 • e-mail: vica [email protected] om Austra lasia Phone: 86-21-58855151 • Fax : 86-21-58851298 • e-mail: vica p@victau lic.com  Styles 920 and 920N Mechanical-T  ®  Bolted Branch Outlets  PRODUCT DESCRIPTION  V i ct aul i c M echanical -T  ®  O utlet prov i d es a d irec t branch co nnect i on at an y l ocation a h ole can b e c ut in p i p e. The hol e i s c ut ove r size t o r eceive a holef ind er”locating collar w hi ch se cures t he out let in posi t i on p er m an en t l y. A p r essu r e r esp onsive gasketseals on the p i p e O . D . C r oss-t yp e c onnection s ca n b e a chiev ed b y ut ilizing t w o u p p er housing s of t he sa m e styl e a nd size, w ith t he sam e or di f feri ng b r an ch size conne ct i on s. N O TE :Style 920 an d Style 920N ho usi ngs cannot  b e m at ed t o ac hieve a cross connec t i on . S t yle 9 20 and S tyl e 9 20 N M ec ha ni cal- T o ut let s a r e a va ilab l e w i t h g r oo ve d or fem ale threaded outlet. S p ec ify choice on order. U nits are supplied p ai nted w i t h p lated bol t s. G al va ni zed housing s are av ai l ab le, su p p l ied w ith p l ated bol t s. A llsizes o f S tyle 920 an d 920N are rated at 50 0 p si(3450 kP a) wor ki ng p r essu r e o n S ched ul e 10 a nd 40 car b on st eelpipe. Th ey m ay a lso be used on hi gh densit y p ol yet hyl en e o r pol yb utylen e ( H D P E) pipe. P r es sure rating s o n H DPE are d ep en d ent on the pipe rat i ng .Contac t V ictaulic for r at i ng s o n o ther p i p e. Style 920 and 920N are not recommended for use on PVC plastic pipe.  S t andard piping practices dict at e thatthe M ec ha ni ca l - T S tyl es 9 20 an d 920N m ust b e install ed so that t he m ai n a nd branch co nn ections are a true 90° an g l e w he n p er m an en t l y at t ached t o t he p i p el ine sur f ace.  MATERIAL SPECIFICATIONS  Housing/Coating  : D uctile i r on co nf or m ing t o A STM A -536, grade 65 - 45 - 12 ,w ith or an g e en am el co at i ng . D uc tile i r on co nf orm ing t o A STM A - 39 5, grad e 6 5-45-15,is avail ab le upon sp ec i al request.   Optional:  Hot di p p ed g alvanized  Gasket:  ( S p ecif y ch oi ce*)   Grade “E” EPDM  E P D M ( G r een co lor co d e) .Te m p er ature r ang e –30°F to +230° F ( 34 ° C t o + 110 °C ) . R ec om m en ded for cold and ho t w ater se rvice w it hin t he sp ecifi ed t em p er at ure ran g e p l us a va r iet y o fdil ut e acid s, oi l-free ai r an d m an y ch em icalservices.U L C l assi f i ed i n a ccor d an ce w it h A N SI / N S F 6 1 f or co ld +86° F (+30°C) and hot+180° F ( +82°C) NO T REC O M M ENDED FO R PETRO LEUM SERVICES.   Grade “T” nitrile  N i t rile ( O r an ge color cod e) .Te m p er at ur e r an g e – 20 °F t o +18 0°F ( 29 °C to + 82 °C ) . R ec om m ended for p et r ol eum p rod uc ts, ai r w i t h oil va p ors, ve g etab le a nd m ineral oil s w i t hi n t he sp eci f i ed t em p er at ure r an g e. N ot rec om m en ded f or hot w at er ser vices over +15 0°F ( +66° C ) or for hotdr y ai r over + 140°F (+60° C ). *Service s l i sted are G en eral S ervi ce R ec om m end at ions onl y. It sh ould be noted t hatt he r e a r e se r vi ce s f or w hi ch t hese gaskets are n ot r ec om m en d ed . R ef er en ce should al w ays b e m ad e t o the latest V ictaulic G as ke t S election G ui d e f or sp ecific gas ke t service rec om m endation s a nd f or a l isting of se rvice s w hi ch ar e not r ecom m ended.  Bolts/Nuts:  H eat-trea t ed p l at ed ca r b on st ee l, t r ac kh ea d m eeting t he physical an d ch em i ca l r equi r em ents of A ST M A -449 and ph ysicalr eq uir em ent s of A ST M A -183. U L C U L  ® FM See Victaulic publication 10.01 for details. Styles 920 and 920N Style 920 Cross See chart on page 5 for pressure ratings. VdS

HDPE Style920

Embed Size (px)

Citation preview

Page 1: HDPE Style920

8/11/2019 HDPE Style920

http://slidepdf.com/reader/full/hdpe-style920 1/5

IPS CARBON STEEL PIPE – HOLE CUT PRODUCTS

VICTAULIC ® IS AN ISO 90 01 CERTIFIED CO

® REGISTERED TRADEMARK OF VICTAULIC – © COPYRIGHT 2005 VICTAULIC – PRINTED IN U.S.A. – SKU #WCAS-6CJJCL 1480 REV H

11.02

United States • Phone: 1-800-PICK-VIC (1-800-742- 5842) • Fax: 610-250-8817 • e-mail: [email protected] • Phone: 905-884-7444 • Fax: 905-884-9774 • e-mail: [email protected] • Phone: 32-9-381- 1500 • Fax: 32-9-380-4438 • e-mail: [email protected] • Phone: 44(0)1438741100 • Fax: 44(0)1438313883 • e-mail: [email protected]

Central and South America • Phone: 610-559-3300 • Fax: 610-559-3608 • e-mail: [email protected] • Phone: 86-21-58855151 • Fax: 86-21-58851298 • e-mail: [email protected]

Styles 920 and 920N Mechanical-T

®

Bolted Branch Outlets

PRODUCT DESCRIPTION

Victaulic M echan ical-T

®

O utlet p rovides a d irec t b ran ch co nn ec tion at an y loc ation a h ole c an be c ut inp ipe. The hole is cut ove rsize to receive a “holefinder”locating collar w hich secures the outlet in positionperm an en tly. A p ressu re resp on sive g aske t sea ls on the p ip e O .D .

C ross-typ e con ne ction s ca n b e ach ieved by utilizing tw o upper ho using s of the sam e style and size, w iththe sam e o r d iffering b ran ch size c on nections. N O TE : S tyle 9 20 an d S tyle 9 20 N ho using s cannot

bem ated to achieve a cross c onn ec tion .

S tyle 9 20 an d S tyle 9 20 N M ec ha nica l-T o utlets are a vailab le w ith g roo ved or fem ale thread ed ou tlet.Spec ify c ho ice on orde r. U nits a re supp lied painted w ith p lated bolts. G alvanized ho using s a re availab le,supp lied w ith p lated b olts.

A ll sizes o f S tyle 920 and 920N are rated at 50 0 p si (34 50 kPa) w orking p ressu re on S ch ed ule 10 and 40ca rb on stee l p ipe. Th ey m ay a lso b e u sed on high d en sity p olyethylen e o r p olyb utylen e (H D P E) p ip e.P ressure rating s on H D PE are d ep en d en t on the p ipe rating . C on tac t V ictau lic for rating s on o the r p ipe.Style 920 and 920N are not recommended for use on PVC plastic pipe.

Stan d ard p ip ing p rac tice s d ictate tha t the M ec ha nica l-T S tyles 9 20 an d 92 0N m ust b e installed so tha tthe m ain a nd b ranch co nnec tion s are a true 90° an g le w he n p erm anen tly attac he d to the p ip eline surfac e.

MATERIAL SPECIFICATIONS

Housing/Coating

: D uc tile iron conform ing to A STM A -53 6, g rad e 65 -45 -12 , w ith oran ge en am el coating .D uc tile iron co nform ing to A S TM A -39 5, g rad e 65-45-15, is ava ilab le upon sp ec ial req ue st.

Optional:

H ot d ipped galvan ized

Gasket:

(Sp ec ify choice*)

Grade “E” EPDM

E PD M (G reen co lor code). Tem perature rang e –30°F to + 230 °F (–34°C to + 110 °C ). R ecom m ended forcold and ho t w ater se rvice w ithin the sp ecified tem p erature range p lus a variety o f d ilute acid s, oil-freeair an d m any ch em ica l services. U L C lassified in accordan ce w ith A N SI/N SF 61 for co ld + 86 °F(+30°C ) and ho t +180°F (+82°C ) N O T REC O M M EN D ED FO R PETRO LEUM SERVIC ES.

Grade “T” nitrile

N itrile (O ran ge co lor cod e). Tem p erature rang e –20°F to + 18 0°F (–29 °C to + 82 °C ). R ec om m end ed forp etroleum p rod uc ts, air w ith o il vapors, vegetab le a nd m ineral oils w ithin the sp ecified tem peratureran ge. N ot rec om m en ded for ho t w ater service s ove r + 150°F (+ 66°C ) or for ho t d ry air ove r + 14 0°F(+ 60°C ).

*S ervice s listed are G en eral Service R ec om m en d ation s only. It shou ld b e n oted tha t the re a re service s forw hich the se g aske ts are not rec om m en ded . R eferen ce sho uld a lw ays b e m ad e to the latest V ictau licG asket Selec tion G uide for spec ific gasket service rec om m en d ation s and for a listing of service s w hichare not recom m ended .

Bolts/Nuts:

H ea t-trea ted p lated ca rbon stee l, trac khea d m ee ting the physica l an d ch em ica lreq uirem ents of A ST M A -449 and ph ysical req uirem ents of A ST M A -183.

ULCUL ®

FM

See Victaulicpublication 10.01

for details.

Styles 920 and 920N

Style 920 Cross

See chart on page 5 for pressure ratings.

VdS

Page 2: HDPE Style920

8/11/2019 HDPE Style920

http://slidepdf.com/reader/full/hdpe-style920 2/5

2 S tyles 920 and 920N M echanical-T

®

B olted B ran ch O utlets

11.02

DIMENSIONS

NOTE: Style 920 and Style920N housings cannot bemated to achieve crossconnections.

Y

TV

W

Z

Y

V

W

Z

Styles 920 and 920N

Styles 920 and 920Nw/Female Threaded Outlet

w/Grooved Outlet

Th ese n ew size S tyle92 0N produ cts req uire ad ifferent ho le s ize thanthe S tyle 92 0 it rep lac es ,for prop er installation.U se c aution to a ssurethe p rop er size ho le isp rep ared for the sp ec ificsize an d style u sed .Fa ilure to use the p rop erhole size co uld resu lt injoint lea kag e an dproperty da m age.

NEW

HOLE SIZE

SIZERun X Branch

Nominal Inchesmm

StyleNo.

Max.Work.Press.

PSIkPa

Dimensions – Inches/millimeters Aprx.Wgt. Each

Lbs./kgHoleDia.

+0.13–0.00 T **

Fem.Thd.

V‡ #

Grv.V‡ W Y Z

Fem.Thd. Grv.

2 X

1

/

2

(a) 920N 500 1.50 2.00 2.53 – 1.61 5.35 2.75 3.1 –

50 X 15 3450 38,1 51 64 – 41 136 70 1,5 –

X

3

/

4

(a) 920N 500 1.50 1.97 2.53 – 1.61 5.35 2.75 3.1 –

X 20 3450 38,1 50 64 – 41 136 70 1,5 –

X 1 (a) 920N 500 1.50 1.85 2.53 – 1.61 5.35 2.75 3.0 –

X 25 3450 38,1 47 64 – 41 136 70 1,4 –

X 1

1

/

4

(a) 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2

X 32 3450 44,5 52 70 76 41 136 76 1,7 1,5

X 1

1

/

2

(a) 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2

X 40 3450 44,5 52 70 79 41 136 83 1,7 1,5

2

1

/

2

X

1

/

2

(a) 920N 500 1.50 2.21 2.74 – 1.86 5.64 2.75 3.0 –

65 X 15 3450 38,1 56 70 – 47 143 70 1,4 –

X

3

/

4

(a) 920N500 1.50 2.18 2.74 – 1.86 5.64 2.75 3.0 –

X 20 3450 38,1 55 70 – 47 143 70 1,4 –

X 1 (a) 920N 500 1.50 2.06 2.74 – 1.86 5.64 2.75 2.9 –

X 25 3450 38,1 52 70 – 47 143 70 1,4 –

X 1

1

/

4

(a) 920N500 1.75 2.30 3.00 3.25 1.86 6.29 3.00 3.5 3.2

X 32 3450 44,5 58 76 83 47 160 76 1,7 1,5

X 1

1

/

2

(a) 920N500 2.00 2.28 3.00 3.25 1.86 6.26 3.25 3.6 3.3

X 40 3450 50,8 58 76 83 47 159 83 1,7 1,6

76,1 m m X

1

/

2

(a) 920 300 1.50 2.22 2.75 – 1.88 6.46 3.16 3.9 –

X 15 2065 38,1 56 70 – 48 164 80 1,8 –

X

3

/

4

(a) 920 300 1.50 2.19 2.75 – 1.88 6.46 3.16 3.9 –

X 20 2065 38,1 56 70 – 48 164 80 1,8 –

X 1 (a) 920 300 1.50 2.07 2.75 – 1.88 6.46 3.16 3.8 –

X 25 2065 38,1 53 70 – 48 164 80 1,7 –

X 1

1

/

4

(a)

920N500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2

X 32 3450 44,5 58 76 84 49 160 76 1,6 1,5

X 1

1

/

2

(a) 920N500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3

X 40 3450 50,8 58 76 84 49 160 83 1,6 1,5

3 X

1

/

2

(a) 920N 500 1.50 2.52 3.05 – 2.28 6.15 2.75 3.4 –

80 X 15 3450 38,1 64 78 – 58 156 70 1,6 –

X

3

/

4

(a) 920N500 1.50 2.49 3.05 – 2.28 6.15 2.75 3.4 –

X 20 3450 38,1 63 78 – 58 156 70 1,6 –

X 1 (a) 920N 500 1.50 2.38 3.06 – 2.28 6.15 2.75 3.3 –

X 25 3450 38,1 61 78 – 58 156 70 1,6 –

X 1

1

/

4

(a)

920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7

X 32 (b ) 3450 44,5 65 83 90 58 156 76 1,8 1,8

X 1

1

/

2

(a)

920N500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8

X 40 (b ) 3450 50,8 71 89 90 58 156 83 1,9 1,8

X 2 (a) 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6

X 50 3450 63,5 70 89 90 58 172 99 2,3 2,1

3

1

/

2

X 2920N

500 2.50 – – 3.75 2.44 6.72 3.88 – 3.8

90 X 50 3450 63,5 – – 95 62 171 99 – 1,8

4 X

1

/

2

(a) 920N 500 1.50 3.03 3.56 – 2.69 7.01 2.75 3.7 –

100 X 15 3450 38,1 77 90 – 68 178 70 1,8 –

X

3

/

4

(a) 920N500 1.50 3.00 3.56 – 2.69 7.01 2.75 3.7 –

X 20 3450 38,1 76 90 – 68 178 70 1,8 –

X 1 (a) 920N 500 1.50 2.88 3.56 – 2.69 7.01 2.75 3.6 –

X 25 3450 38,1 73 90 – 68 178 70 1,8 –

X 1

1

/

4

(a)

920N500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6

X 32 (b ) 3450 44,5 78 96 102 68 178 76 1,9 1,8

X 1

1

/

2

(a)

920N500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9

X 40 (b ) 3450 50,8 83 102 102 68 178 83 2,0 1,9

X 2 (a)920N

500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6

X 50 3450 63,5 83 102 102 68 178 99 2,3 2,1

X 2

1

/

2

(a) 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0

X 65 3450 69,9 73 102 102 68 186 118 2,6 2,3

X 76,1 m m 920 500 2.75 – – 4.00 2.69 7.34 4.63 – 6.4

3450 69,9 – – 102 68 186 118 – 2,9

X 3 (a) 920 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4

X 80 3450 88,9 84 114 105 68 196 130 3,8 2,9

Table continued on page 3. See notes on page 4.

Page 3: HDPE Style920

8/11/2019 HDPE Style920

http://slidepdf.com/reader/full/hdpe-style920 3/5

11.02

S tyles 920 and 920N M echanical-T

®

B olted B ranch O utlets 3

DIMENSIONS

µ

NOTE: Style 920 and Style920N housings cannot bemated to achieve crossconnections.

Y

TV

W

Z

Y

V

W

Z

Styles 920 and 920N

Styles 920 and 920Nw/Female Threaded Outlet

w/Grooved Outlet

The se n ew size S tyle920 N produ cts req uire ad ifferent hole size thanthe S tyle 92 0 it rep lac es,for prop er installation.U se c aution to a ssurethe prop er size ho le isprep ared for the sp ec ificsize an d style use d .Fa ilure to use the p rop erhole size could resu lt injoint lea kag e an dproperty d am age.

NEW

HOLE SIZE

SIZERun X Branch

Nominal Inchesmm

StyleNo.

Max.Work.Press.

PSI/kPa

HoleDia.

+0.13–0.00

Dimensions – Inches/millimeters Aprx. Wgt. Ea.Lbs./kg

T **

Fem.Thd.V ‡ #

Grv.V ‡ W Y Z

Fem.Thd. Grv.

108,0 m m X 1

1

/

4

(a) 920N500 1.75 3.08 3.78 – 2.63 7.64 3.05 5.0 –

X 32 3450 44,5 78 96 – 67 194 78 2,3 –

X 1

1

/

2

(a) 920N 500 2.00 3.28 4.00 – 2.63 7.64 3.25 5.0 –

X 40 3450 50,8 83 102 – 67 194 83 2,3 –

X 2 (a)920N

500 2.50 3.25 4.00 – 2.63 7.64 4.00 4.0 –

X 50 3450 63,5 83 102 – 67 194 102 1,9 –

76,1 m m 920500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 –

3450 69,9 73 102 102 67 194 109 3,6 –

X 3 (a)920

500 3.50 3.31 4.50 – 2.63 7.63 4.88 6.8 6.5

X 80 3450 88,9 84 114 – 67 194 124 3,1 3,0

5 X 1

1

/

2

(a)

920 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6

125 X 40 3450 50,8 102 121 121 80 246 94 3,4 3,4

X 2 (a) 920 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0

X 50 3450 63,5 102 121 121 80 246 111 3,7 3,6

X 2

1

/

2

(a) 920500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9

X 65 3450 69,9 92 121 121 80 246 118 3,8 3,6

X 3 (a) 920 500 3.50 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8

X 80 3450 88,9 97 127 118 80 246 135 3,8 4,0

133,0 m m X 2 920N 500 2.50 3.75 4.50 – 3.17 8.00 3.88 8.0 –

X 50 3450 63,5 95 114 – 81 203 99 3,6 –

X 3920

500 3.50 3.81 5.00 – 3.00 9.46 5.31 8.0 –

X 80 3450 88,9 97 127 – 76 240 135 3,6 –

139,7 m m X 1

1

/

2

920N 500 2.00 3.78 4.50 – 3.30 8.23 3.25 7.0 –

X 40 3450 50,8 96 114 – 84 209 83 3,2 –

X 2920N

500 2.50 3.75 4.50 – 3.30 8.23 3.88 9.0 –

X 50 3450 63,5 95 114 – 84 209 99 4,1 –

X 76,1 m m (a)(b ) 920500 2.75 3.63 4.75 – 3.13 9.85 4.63 8.8 –

3450 69,9 92 121 – 80 250 118 4,0 –

X 76,1 m m 920500 3.50 – – 4.63 3.16 9.70 5.31 11.0 –3450 88,9 – – 118 80 246 135 5,0 –

X 3920

500 3.50 3.81 5.00 4.63 3.16 9.85 5.38 14.0 14.2X 88,9 3450 88,9 96.80 127 118 80 250 137 6,4 6,4

6 X 11/4 920N 500 1.75 4.43 5.13 – 3.79 9.15 3.25 – 4.8150 X 32 (b ) 3450 44,5 112 130 – 96 232 83 – 2,2

X 1 1/2 (a) 920N500 2.00 4.40 5.12 5.13 3.79 9.15 3.25 5.4 5.1

X 40 (b ) 3450 50,8 112 130 130 96 232 83 2,4 2,3

X 2 (a) 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6X 50 3450 63,5 111 130 130 96 232 99 2,7 2,5

X 2 1/2 (a) 920 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6X 65 3450 69,9 110 130 130 94 267 118 3,8 3,4

X 76,1 m m (a)(b ) 920500 2.75 – – 5.21 3.69 10.51 4.63 – 8.43450 69,9 – – 132 94 267 118 – 3,8

X 3 (a)920

500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4X 80 3450 88,9 110 140 130 94 267 135 4,5 3,8

X 4 (a)920

500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1X 100 3450 114,3 97 146 137 94 267 159 4,6 4,6

159,0 m m X 11/4 920N 500 1.75 4.43 5.13 – 3.63 9.40 3.25 9.0 8.7X 32 3450 44,5 113 130 – 92 239 83 4,1 4,0

X 1 1/2 (a)920N

500 2.00 4.41 5.13 – 3.63 9.40 3.25 7.8 –X 40 3450 50,8 112 130 – 92 239 83 3,5 –

X 2 (a)920N

500 2.50 4.38 5.13 – 3.63 9.40 3.88 8.0 –X 50 3450 63,5 111 130 – 92 239 99 3,6 –

X 76,1 m m 920500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.53450 69,9 111 140 130 92 239 118 4,3 4,3

X 3920

500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0

X 80 3450 88,9 110 140 130 92 239 135 3,7 6,4

X 108,0 m m 920500 4.50 – – 5.38 3.63 9.40 6.12 – 10.03450 114,3 – – 137 92 239 155 – 4,5

X4

920500 4.50 3.81 5.75 – 3.63 9.40 6.25 18.0 –

100 3450 114,3 96.80 146 – 92 239 159 8,2 –

Table continued on page 4. See notes on page 4.

Page 4: HDPE Style920

8/11/2019 HDPE Style920

http://slidepdf.com/reader/full/hdpe-style920 4/5

4 Styles 920 and 920N M echanical-T®

B olted B ran ch O utlets

11.02

DIMENSIONSµ

NOTE: Style 920 and Style920N housings cannot bemated to achieve crossconnections.

Y

TV

W

Z

Y

V

W

Z

Styles 920 and 920N

Styles 920 and 920Nw/Female Threaded Outlet

w/Grooved Outlet

Th ese n ew size S tyle92 0N produ cts req uire ad ifferent ho le s ize thanthe S tyle 92 0 it rep lac es ,for prop er installation.U se c aution to a ssurethe p rop er size ho le isp rep ared for the sp ec ificsize an d style u sed .Fa ilure to use the p rop erhole size co uld resu lt injoint lea kag e an dproperty da m age.

NEW

HOLE SIZE

NOTES**C enter of run to e ng ag ed p ip e e nd ,fem ale thread ed ou tlet on ly (D im en -sion s app roxim ate). A vailab le w ith groove d or fem alethread ed ou tlet. Spec ify c ho ice onorder.‡ C en ter of run to en d of fitting .# F em ale threa ded ou tlets a re a vail-ab le to N P T an d B S PT spe cification s.(a) British S tan dard fem ale p ipethreaded ou tlet is a va ilab le as listed .Spec ify “B SPT”clea rly o n order.(b) Fo r 76 ,1 m m thread ed ou tlet,sp ec ify 2 1/2" B SP T c lea rly on order.

SIZERun X Branch

Nominal Inchesmm

StyleNo.

Max.Work.Press.

PSI/kPa

HoleDia.

+0.13–0.00

Dimensions – Inches/millimeters

Aprx. Wgt. Ea.Lbs./kgT **

Fem.Thd.V ‡ #

Grv.V ‡ W Y Z

165,1 m m X 1 920 500 1.50 8.0 –X 25 3450 38,1 99 116 – 96 237 70 3,6 –

X 1 1/4 920500 1.75 4.43 5.13 – 3.79 9.34 3.25 8.4 –

X 32 3450 44,5 113 130 – 96 237 83 3,8 –

X 1 1/2 (a) 920 500 2.00 4.41 5.13 – 3.79 9.34 3.25 8.4 –X 40 3450 50,8 112 130 – 96 237 83 3,8 –

X 2 (a)920

500 2.50 4.38 5.13 – 3.79 9.34 3.88 8.5 –X 50 3450 63,5 111 130 – 96 237 99 3,9 –

X 2 1/2 920 500 2.75 4.01 5.13 – 3.63 10.51 4.63 8.6 7.6X 65 3450 69,9 110 130 – 92 267 118 3,9 3,4

X 76,1 m m (a)(b) 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.63450 69,9 110 130 132 92 267 118 3,9 3,4

X 3 (a) 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4X 80 3450 88,9 110 140 130 92 267 135 4,6 3,8

X 4 (a) 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4X 100 3450 114,3 97 146 137 92 267 159 4,8 3,8

8 X 2 (a) 920 500 2.75 5.44 6.19 – 4.81 12.42 4.50 11.6 –200 X 50 3450 69,9 138 157 – 122 316 114 5,3 –

X 21/2 (a) 920500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6

X 65 3450 69,9 129 157 157 122 316 114 5,3 5,3

X 3 (a)920

500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6X 80 3450 88,9 135 165 165 122 316 135 5,7 5,3

X 4 (a) 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5X 100 3450 114,3 122 171 162 122 316 159 6,9 5,7

Page 5: HDPE Style920

8/11/2019 HDPE Style920

http://slidepdf.com/reader/full/hdpe-style920 5/5

11.02

Styles 920 and 920N M echanical-T®

B olted B ranch O utlets 5

FLOW DATA

Formulas for CV Values:

APPROVED PRESSURE RATINGSThe inform ation p rovid ed below is b ased on the lates t listing an d ap proval data a t the tim e o f pub lication.Listing s/A pprovals a re sub jec t to ch an ge an d /or ad d ition s b y the ap p rovals agen cies. C on tac t V ictau licfor perform an ce on othe r p ip e an d the latest listing s a nd ap p rovals.

Flow test data h as sh ow n tha tthe total he ad loss betw ee np oint (1) and (2) for the S tyle920, 900N and 929M echa nica l-T ® fitting s canb est be exp resse d in term s ofthe p ressure d ifferenc e ac rossthe inlet an d b ran ch . Th ep ressu re d ifferen ce ca n beob taine d from the relationshipto the rig ht.

CV Values

V alues for flow of w ater at+ 60°F (+ 16°C ) are show n inthe tab le at right.

1

2

Exaggerated for C larity

OUTLET SIZE Equivalent LengthFeet/meter of Pipe

OUTLET SIZE Equivalent LengthFeet/meter of Pipe

NominalDiameterIn./mm

ActualOut. Dia.In./mm Grooved

FemaleThreaded

NominalDiameterIn./mm

ActualOut. Dia.In./mm Grooved

FemaleThreaded

1/2 0.840 – 2.0 2 2.375 9.0 10.515 21,3 – 0,6 50 60,3 2,7 3,23/4 1.050 – 4.0 2 1/2 2.875 11.0 12.520 26,7 – 1,2 65 73,0 3,4 3,8

1 1.315 – 5.0 3 3.500 13.5 15.525 33,7 – 1,5 80 88,9 4,1 4,7

1 1/4 1.660 5.5 6.0 4 4.500 20.0 22.032 42,4 1,7 1,8 100 114,3 6,1 6,7

1 1/2 1.900 7.0 8.040 48,3 2,1 2,4

Pipe Size

CV

Values

Pipe Size

CV

Values

Pipe Size

CV

Values

NominalDiameter

Inches/mm

ActualOutsideDiameter

Inches/mm

NominalDiameter

Inches/mm

ActualOutsideDiameter

Inches/mm

NominalDiameter

Inches/mm

ActualOutsideDiameter

Inches/mm1/2 0.84 0 17 1 1/4 1.660 45 21/2 2.87 5 13515 21,3 32 42,4 65 73,03/4 1.05 0

21 1 1/2 1.90060

3 3.50020020 26,7 40 48,3 80 88,9

1 1.315 25 2 2.375 100 4 4.500 40025 33,7 50 60,3 100 114,3

P ∆ Q2

C V 2

---------=

Q C V ∆ P ×=

Where:Q = Flow (G PM ) C V = Flow C oe fficien t

∆ P = P ressure D rop (psi)

Run Size

Outlet SizeInches/mm

PipeSchedule

Rated Working PressuresPSI/kPa

NominalDiameter

Inches/mm

ActualOutsideDiameter

Inches/mm UL ULC FM21/2 - 6 2.875 - 6.625 A ll 10, 40 400 400 40065 - 150 73,0 - 168,3 2755 2755 2755

21/2 - 4 2.875 - 4.500 A ll D F 300 300 30065 - 100 73,0 - 114,3 2065 2065 2065

21/2 - 4 2.875 - 4.500A ll SF

300 300 30065 - 100 73,0 - 114,3 2065 2065 2065

6 6.6253, 4 10

300 300 250150 168,3 2065 2065 1724

6 6.6253,4 30, 40

300 300 300150 168,3 2065 2065 2065

8 8.6252 1/2 10 , 40 400 – –

200 219,1 2755 – –

8 8.625 3,4 10 300 – 250200 219,1 2065 – 1724

8 8.625 3,4 30, 40 300 – 300200 219,1 2065 – 2065

N O TE S: 10 refers to L isted /A pp roved Sc hed ule 1 0 stee l sprinkler pipe .40 refers to L isted /A pp rove d Sch ed ule 4 0 s tee l sp rinkler pipe.D F refers to Listed /A pp roved D yna-Flow steel sprinkler pipe m anu fac tured by A m erica n Tu be C om p any.SF refers to L isted /A pprove d S up er-Flo steel sp rinkler pipe m an ufac tured by A llied Tu be a nd C on duit C orporation .

Th is p rod uc t shall be m an ufactured by V ictaulic or to Victaulic sp ec ifica tion s. All p rod uc ts to b e installed in ac co rdan ce w ith cu rren t Victaulic installation /assem bly ins truc tion s.V ictau lic rese rves the rig ht to ch an ge prod uc t sp ec ifica tion s, des igns an d stan dard eq uipm en t w itho ut notice an d w itho ut inc urring ob lig ation s.