HANDHELD FORCE MEASURING INDICATOR HHI
Contents Specifications and Parameters……………………………………………… 2 Appearance and Dimensions ……………………………………………… 4 Test Benches ……………………………………………………………… 5 Precautions ………………………………………………………………… 6 Functions …………………………………………………………………… 7 Main Features ……………………………………………………………… 7 Parts & Buttons and Their Functions ……………………………………… 8 Interfaces and Their Functions………………………………………………12 Test Description ……………………………………………………………19 Software …………………………………………………………………… 21 Maintenance and After-Sales Service ………………………………………26 Battery Use and Maintenance ………………………………………………27 Packing List …………………………………………………………………28
Load Cell Systems reserves the right to change specifications without notice. ©2018
Web: https://loadcellsys.com
Email: [email protected]
Phone: 607-426-1467
Specifications and Parameters (for Embedded Products)
TX-5
00
500N
0.1N
1Mpa
Embe
dded
sens
or
1%~1
00%
F.S
±0.
5%F.
S
N、
kg、
lb
2.8-
inch
true
col
or
20±
10℃
15%
~80%
RH
No
vibr
atio
n so
urce
s or c
orro
sive
mat
eria
ls e
xist
.
1kg
TX-2
00
200N
0.1N
TX-1
00
100N
0.05
N
0.1M
pa
TX-5
0
50N
0.01
N
TX-2
0
20N
0.01
N
TX-1
0
10N
0.00
5N
0.01
Mpa
TX-5
5N
0.00
1N
TX-2
2N
0.00
1N
Mod
el
Ran
ge
Cal
ibra
tion
Cal
ibra
tion
f P Sens
or
Mea
surin
g R In
dica
tion
E Uni
ts
Dis
play
Wor
king
T
tR
elat
ive
Hid
itW
orki
ng
Con
ditio
nsW
eigh
t
- 2 -
Specifications and Parameters (for External Products)
Mod
el
TX-1
K
TX-2
K
TX-5
K
TX-1
0K
TX-2
0K
TX-5
0K
TX-1
00K
TX-2
00K
TX-5
00K
TX-1
000K
TX-2
000K
Ran
ge
1000
N
2000
N
5000
N
10kN
20 k
N
50 k
N
100
kN
200
kN
500
kN
1000
kN
2000
kN
Cal
ibra
tion
0.5
N
1 N
1 N
0.00
5kN
0.01
kN
0.01
kN
0.05
kN
0.1
kN
0.1
kN
0.5
kN
1 kN
Sens
e
Exte
rnal
S-s
hape
d se
nsor
Exte
rnal
spok
e se
nsor
Mea
surin
g R
ange
1%~
100%
F.S
Indi
catio
n Er
ror
±1%
F.S
(dep
endi
ng
on th
e se
nsor
co
nfig
ured
)
- 3 -
Appearance and Dimensions
mm
Output Port Wiring
- 4 -
Test Benches (Optional)
- 5 -
Precautions
Misoperation may cause damage to the force gauge and even result in serious accidents. This manual describes precautions againstaccidents and operation methods of this
product. Make sure to read this manual carefully and safe keep it after the reading. For impact test, select a force gauge whose maximum measurable value is doubled the impact load to be applied. Effective measuring range of this product is 10% ~ 100%.
1、 Before the impact test, wear mask and gloves; avoiding personal injury in case of object splash.
2、 Do not use damaged or bent fixture; avoiding personal injury in case of fixture fall or break.
3、 If “Warning: test load exceeds measurement” appears on the LCD display, it indicates that the test load the sensor measures is 110% larger than the rated load. Decrease the load immediately. Make sure the load applied is smaller than 105% the rated load after the force gauge is restarted.
4、 Make sure the force gauge is not overloaded. Overload, excessive impact force, and forces other than pull force and push force may damage the sensor.
5、 Do not use sharp tools to press buttons. 6、 Avoid the force gauge from water, oil, and other liquids. Put it in a cool, dry,
and vibration-free place. 7、 Use the charger delivered with the force gauge for charging; otherwise,
Notes
Warning
- 6 -
circuit failure even fire may be caused. 8、 Follow this document to wire ports; otherwise, circuit failure even PC fault
may be caused. 9、 Make sure the AC charger is securely inserted into a socket if the product
needs to be charged. Looseness may cause short circuit, resulting in electric shock or fire.
10、Remove the power adapter after the charging; avoiding accidents. 11、Do not touch the power adapter with wet hands; otherwise, electric shock
may occur. 12、This product is for measuring pull and push forces only. Do not bend or
twist the test head. See the following figure for correct operation method.
Functions
BIN-106 series digital force gauges are new-generation universal portable instruments for testing pull and push forces. They are characterized by compactness, lightness, portability, versatility, high precision, and curve capture, applicable to pull & push test, insertion & extraction test, and impact test of various products. They can be also designed into small-sized test machines for various purposes when they are combined with different test benches and fixtures.
Main Features
1、 2.8-inch TFT true color display; both direction buttons and display can be rotated 180°.
2、 Built-in real time clock;USB interface; hot swappable. - 7 -
3、 Peak values, real-time values, and test curves can be displayed on the same screen; enabling procedural monitor and reproduction of the test.
4、 Free setting of fracture alarm value, fracture alarm dead zone, and upper/lower offset; selection of fracture alarm, alarm for not excess of limit, and alarm for excess of limit. When alarm values are exceeded, the buzzer acts while the display shows alarm information. The two SC open-collector level outputs drive the DC 12V relay or the solenoid to act, each output being 50mA. To use output ports, connect the power adapter first.
5、 Enable automatic unit conversion: N, kg, and lb; pressure unit MPa can be converted as well.
6、 Peaks can be held or cleared; clearing time can be set. 7、 A maximum of 100 groups of test reports can be saved permanently. The
saved content includes test time, peak, and average valley. One group of test curves can be saved(Automatically cleared after shutdown) as well for reproducing the test procedure.
8、 Material strength can be calculated based on sectional area input. 9、 Shutdown and backlight can be set to perform automatically. 10、Chinese/English switchover; pictures and literary descriptions make various
operations easy to understand and learn. 11、Relying on the PC dedicated test software, the force gauge can realize
unlimited storage, transmission, and reproduction of test curve data. 12、Installed on different test benches, the force gauge can implement various
tests.
- 8 -
Parts & Buttons and Their Functions (for Embedded Products)
- 9 -
Parts & Buttons and Their Functions (for External Products)
Wiring methods of the sensor: 1——V+
;2——V-;
3——S+;4——S-
; 5——P
- 10 -
Buttons and Their Functions
Button Standalone
Test Mode
Capture
Mode
Online Test
Mode
Storage &
Query Mode
Menu Operation
Mode
Shutdown Invalid Shutdown Invalid Invalid
Invalid Quit
capture Invalid Exit
Quit parameter
modification or
exit
Zero set Invalid Zero set Invalid Invalid
Test
output Invalid Invalid Up Up
Enter
storage &
query
mode
Invalid Invalid
Switch to
upper
window
Down
Enter
parameter
setting
mode
Capture
stop Invalid
View report
and output
test value
Confirm
parameter
modification
Curve
capture
start
Invalid
Curve
capture
start
Move the blinking number
leftward by one unit
Peak
clearing Invalid
Peak
clearing
Move the blinking number
rightward by one unit
- 11 -
Interfaces and Their Functions
1、Test Interface: Press and hold the "ON/OFF" button to start the force gauge. The following interface appears.
⑦、Number of reports saved⑧、Sampling Speed⑨、Upper limit alarm⑩、Peak hold time、Peak-to-peak
①、Battery level②、Curve③、Real-time force④、Lower limit alarm⑤、First peak⑥、Valley-to-peak
- 12 -
Test Functions ①、Battery level: real-time display. In case of power shortage, this icon blinks
and an alarm is reported. ②、Curve: force-to-time curve.③、Force: real-time display. A maximum of 5 digits can be shown. Its unit can
be converted on the setting interface. ④、Lower limit alarm: values can be specified on the setting interface.⑤、First peak: the first peak value after the test starts.⑥、Valley-to-peak: the minimum force that is smaller than the initial value.⑦、Number of reports saved: a maximum of 100 groups of reports can be saved
and the latest group of test curves can be saved as well. ⑧、Display sampling speed.⑨、Upper limit alarm: values can be specified on the setting interface.⑩、Peak hold time: this parameter can be set on the setting interface and
manually cleared. 、Peak-to-peak: the maximum positive peak.
2、Interface Setting On the test interface, press "OK" to enter the setting interface. The setting interface falls into 2 pages.
- 13 -
【Display Unit】 When the main unit is set to "g", available values of [Display Unit] include:
"g", "mlb", "mN", and "Pa".When the main unit is set to "kg", available values of [Display Unit] include:
"kg", "lb", "N", and "KPa".When the main unit is set to "t", available values of [Display Unit] include:
"t", "klb", "kN", and "MPa".【Force Area】
When [Display Unit] is set to "Pa", "KPa", or "MPa", [Force Area] will involve in calculation.
Note: Pressure test result will be accurate only when [Force Area] is set.【Zero Tracking】
Available values include "shutdown", "1d", "2d", "3d", "4d", and "5d". Before the zero point becomes stable, values smaller than [Zero Tracking]
are automatically cleared. After the test values become stable, test frequency is once per second. Variants of the test values that are smaller than [Zero Tracking] are automatically cleared, to hold the displayed values. 【Sampling Speed】
When it is set to "6Hz ~ 1600Hz", it indicates force sampling speed per second.
Note: The higher the sampling speed, the lower the test accuracy. Higher sampling speed applies to dynamic and transient test; and lower sampling speed applies to static and slow test. 【Calibrate Grav】The Gravity of calibration place adding speed 【User Gravity】The Gravity of Using place adding the speed
Its value is "9.600 ~ 9.900" N/Kg. This parameter is used for gravity correction. The displayed value = test
value + test value * ([Calibrate Grav] – [User Gravity]). 【Alarm Upper LV】For setting alarm upper limit value. 【Alarm Lower LV】For setting alarm lower limit value.
- 14 -
【Alarm mode】 Values of this parameter include "Within", "Beyond", "Fracture", and "Shut
Off"; they are indicative of within limit alarm, beyond limit alarm, fracture alarm, and shutoff alarm.
If the value is set to "Within" or "Beyond", when the alarm value is exceeded, the buzzer acts while the display shows alarm information. Meanwhile, the Boolean value is output. The following figure shows differences between within limit alarm and beyond limit alarm.
If the value is set to "Fracture", [Alarm Upper LV] and [Alarm Lower LV] will be automatically switched to [Fracture Alarm] and [Fracture Dead]. Set these two parameters. When the force variation is reduced to the set value, the buzzer acts while the display shows alarm information. Meanwhile, the upper Boolean value is output.
Note: To use output ports, connect the power adapter first. The two SC open-collector level outputs drive the DC 12V relay or the solenoid to act, each output being 50mA. 【Peak V. Hold】a switch for enabling peak hold function
Its values include "on" and "off".If this parameter is set to "off", the peak value will not be displayed on the
interface.【External Input】external switch for enabling capture
Its values include "on" and "off". - 15 -
When this parameter is set to "on", enabling the external switch (equivalent to the "curve capture" button or the "curve capture" instruction) to be turned on, the force gauge will enter curve capture mode. Note: capture time length is subject to the sampling speed. Capture time (unit: second) = number of captured data / sampling speed【Peak Hold Time】
Its values include "Clr by Key" and "1 ~ 60 sec". When this parameter is set to "Clr by Key", the peak remains unchanged
until users press the "Peak Clearing" button or "Zero Set" button. When this parameter is set to "1 ~ 60 sec", the peak will be automatically re-measured after the set time is up. The peak can also be re-measured by manually pressing the "Peak Clearing" button or "Zero Set" button.【Capture Lenght】
Set range: 1 ~ 1280 secondsThis parameter indicates the curve capture time in capture mode. The
capture time depends on the sampling speed: 60Hz: 1 ~ 1280sec; 12Hz: 1 ~ 640sec; 25Hz: 1 ~ 320sec; 50Hz: 1 ~ 160sec; 100Hz: 1 ~ 80sec; 200Hz: 1 ~ 40sec; 400Hz: 1 ~ 20sec; 800Hz: 1 ~ 10sec; 1600Hz: 1 ~ 5sec. 【Capture Trigge】
Set range: –99999 ~ +99999The [F/P Boundary] parameter serves as a condition of triggering capture
after the force gauge enters the curve capture mode. If the number of data captured reaches utmost or capture is stopped in advance, a capture report will be generated and saved. The curve will be cleared after the force gauge exits the capture mode.【F/P Bounbary】first peak boundary
Set range: 1 ~ 99999This parameter is used for determining first peak during peak test. Take the
assumption that the criteria for determining a peak is 10. After users press the "Peak Re-measuring" button, a new peak test is started. During the test,
- 16 -
peak-to-peak (Vmax), valley-to-peak (Vmin), and new peak (Vnew) are updated continuously. If the absolute value of (Vmax – Vnew) or (Vmin – Vnew) is larger than 10, Vmax or Vmin is considered the first peak.【Buad Rate】serial port baud rate
Set range: 4800 ~ 230400bps Format: 1 initial bit; 8 data bits; 1 stop bit. No parity bit. This parameter will
take effect after users restart the force gauge.Note: In order to ensure that each data is sampled during communication
with a PC, baud rate is recommended to set as follows: 6Hz: ≥ 4800bps; 12Hz: ≥ 9600bps; 25Hz: ≥ 14400bps; 50Hz: ≥ 19200bps; 100Hz: ≥ 28800bps; 200Hz: ≥ 38400bps; 400Hz: ≥ 57600bps; 800Hz: ≥ 115200bps; 1600Hz: ≥ 230400bps. Due to speed limits of serial ports, if the sampling speed is larger than 400Hz, data will be lost when it is transmitted to a PC. Instrument reading results prevail. 【Serial Port】serial port output way
This parameter is used for controlling real-time data transmission. Parameter values and meanings are as follows: Prohibit: The serial port is forbidden to transmit real-time data.
Key/Order: When the button is pressed or an output command is
received, output is performed once. If the force gauge is connected to a PC, PC programs will automatically forbid the output function. Change: When test data changes, output is performed once. Stabilize: When test data becomes stable, output is performed once. Consecutive: Test data is transmitted uninterruptedly.【Display Angle】
This parameter is used for changing display angle. Available values are 0° and 180°. 【Auto Power Off】
This is an energy-saving design. When the force gauge is idled for a specified period, it will automatically shut down.
- 17 -
【Auto Backlight】 This is an energy-saving design. When the force gauge is idled for a
specified period, it will automatically adjust backlight brightness. 【Clear Storage】clearing stored data
This parameter is used for clearing stored test reports and curves. When stored data is overflowed, the system will automatically clear all data and begin storing new captured data. 【Reset User Set】reset parameters
this parameter is used for restoring factory settings in case of wrong setting or other setting problems. 【Language】Chinese/English switchover 【Factory Set A\B\C】【Factory adjustment and self-test】
This parameter is used only during factory setting. Users are not authorized to set this parameter. 【Connection】
This parameter is provided to users for connector wiring. Users can refer to it during connector wiring. 【S/N】local sequence number
This parameter indicates internal sequence number of the machine. Users are not authorized to set this parameter. 3、Calibrate:
①Press "↑", "↓", "←", or "→" to move the cursor to [Calibrate] and press"OK" for confirmation. Then, press any button to enter the calibrationinterface, as shown in figure a.
②Press "↑", "↓", "←", or "→" to move the cursor to [Input Weight] andpress "OK" for confirmation. Press "↑" or "↓" to change "NO" to "YES" andpress "OK" for confirmation.③Press "↑", "↓", "←", or "→" to move the cursor to [CAL Point] and press"OK" for confirmation. Press "↑" or "↓" to set the number of a calibrationpoint to a desired value and press "OK" for confirmation. (The maximum
- 18 -
value of the calibration point is 6.)④Press "↑", "↓", "←", "→", or "OK" to change values of other calibrationpoints and press "OK" for confirmation.⑤Press "↑", "↓", "←", or "→" to move the cursor to [No.0 A/D Code]. Afterthe internal code becomes stable, press "OK" for confirmation. The cursorautomatically moves to [No.1 A/D Code] and the system loads weight that isequivalent to one calibration point. After it becomes stable, press "OK". Thecursor moves on to the next calibration point….After the last calibration point is confirmed, the cursor moves on to [Save Calibrate]. Press "OK" and then press "Back" to exit.
4、Figures b and c show report content (a maximum of 100 groups of reports and 1 group of curves can be saved).
Test Description
After understanding interfaces and functions, you are expected to start test: 1、 Install a head for test. Choose a proper head accessory or fixture for test and
install it onto a rod. Note that do not screw the head with excessive force; otherwise, the sensor may be damaged.
2、 Connect the sensor to the force gauge and install a fixture. Use a wire to connect the sensor connector with the force gauge in a proper manner.
figure a figure b figure c
- 19 -
Choose a proper fixture and install in onto the sensor. Note that do not screw the sensor with excessive force; otherwise, the sensor may be damaged. This step is applicable to external force gauges.
3、 Power-on. Press and hold the "ON/OFF" button for 2 seconds to power on the force gauge. The test interface appears. Check the battery level in the right upper corner of the interface. If battery level is low, connect the force gauge to the delivered power adapter for charging. The force gauge can be charged in both startup mode and shutdown mode. During charging, the force gauge can be tested as well. When the force gauge is fully charged, the system will display a prompt. Remove the power adapter immediately.
4、 Set parameters. On the test interface, press "OK" to enter the setting interface. Set such parameters as unit, force area, zero track, sampling speed, fracture alarm, upper limit alarm, lower limit alarm, peak hold, capture trigger, and capture length. After the setting, press "Back" to go back to the test interface.
5、 Test. Install the sensor onto a proper bench for test. Press the "Zero Set" button and the "Peak Clearing" button. Two test methods are available: one is direct test. In this case, real-time forces, peaks, and other parameter values are obtained which will not be saved. These values will be cleared once a new test is performed. The other method is curve capture. On the test interface, press the "Curve Capture" button to enter the capture mode. The system will automatically start test when the capture trigger condition is met. If users press "OK" or the capture time is up, the test is completed. Peaks, curves and other parameter values will be obtained.
6、 Report query. Test performed in capture mode will be saved, including test curves and test results. Only 1 group of curves can be saved and it can be queried by pressing the "Query" button. If users restart the force gauge or perform a new test, the curves will be cleared. A maximum of 100 groups of reports can be saved and they can be queried by pressing the "Query" button.
7、 Shutdown. Press the "Back" button to go back to the test interface and then press the "ON/OFF" button to shut down the force gauge. The "ON/OFF"
- 20 -
button is effective on the test interface only. Remove the sensor and clean the force gauge. Make sure to put the force gauge back into its box for future use.
Software
While connected to a serial port of a PC over the dedicated USB line, the force gauge can make use of the dedicated software to realize unlimited storage, transmission, and reproduction of test curve data. 1、 Installing software:
Put the disk delivered with the force gauge run into the PC driver and search for the "force gauge test software_setup.exe" file. Double-click the file and follow the steps below to complete installation.
2、 Interface functions: After the installation, click the software icon to start it. When you first start
the software, the absence of any historical test data, so a lot of the content is - 21 -
blank, The following interface appears.
- 22 -
……1. Toolbar: shows various buttons of the software in different modes. Users can click them to perform corresponding operation. ……2. Baud rate: it should be set consistent with the baud rate of the force gauge so that the force gauge can communicate with the PC. ……3. Port number: it should be set to the number of the port over which the force gauge communicates with the PC. ……4. Title bar: shows the name of current project opened. ……5. Project path: indicates the path of the current project opened. ……6. Project file bar: lists all other projects that are stored in the same path as the current project opened. Users can click "Delete" or press the "Delete" button through a keyboard to delete selected files. ……7. Curve file bar: lists all curve files of the current project opened. Users can click "Delete" or press the "Delete" button through a keyboard to delete selected files. ……8. Real-time window: shows test data in real time mode if the force gauge is successfully connected to the PC. ……9. Instruction keyboard: in non-capture mode, users can use the "Instruction keyboard" to operate the force gauge if the force gauge is successfully connected to the PC. ……10. Switch bar: allows users to switch between "Test Curve" "Statistical Report" and “Data sheets”. ……11. Statistical report: shows statistical values of the project under test. ……12. Test data: shows data of various curves of the project under test. ……13. Test parameter: shows parameters for the project under test. ……14. Project title: shows information of the project under test. ……15. Drawing area: draws real-time or historic curves. ……16. Datasheets: display the force value at the time get from historical test project and export data 3、 Online test
1) Use the USB line delivered with the product to connect the force gauge- 23 -
to a PC. To avoid damage to the communication port, make sure the force gauge is powered off.
2) Select the number of a communication port for the force gauge and thePC.
3) Select the baud rate that is consistent with that of the force gauge.4) Press "Online" to connect the force gauge and the PC.5) If online connection fails, follow prompts for check.6) If the system prompts baud rate change, follow the prompt to change
"Sampling Speed" or "Baud Rate" and restart the force gauge. Resetthe baud rate again after the force gauge is restarted.
4、 Creating a project 1) If online connection is successful, click "Create". The "New Test
Project" sheet is shown.2) Enter related information. Note that only white cells are editable.3) Click "OK".4) If the system prompts information, follow the prompt to change the
input and click "OK" again.
5、 Capturing a curve 1) Click "Capture".2) Capture prompt is displayed.3) Confirm the prompt to enter the "Curve Capture" interface. Capture
will be triggered after related conditions are met.- 24 -
4) The system starts curve capture and countdown after capture istriggered. When the timer expires, capture is automatically completed.Curve files will be saved and statistical reports will be updated.
5) During capture, if users click "Re-capture", the captured data will becleared; if users click "Cancel", the capture operation will be canceled.
6、 Opening a project 1) To open a project, users can click "Open" or double-click a project in
the "Project File Bar".2) The project opened is considered the current project and all new curve
files belong to the current project. Statistical reports containinformation of the current project.
7、 Opening a curve file 1) If a project is opened, all curve files of the project will be listed in the
"Curve File Bar".2) Double-click a curve file in the "Curve File Bar" to open the curve.3) For a curve that is successfully opened, curve diagram will be drawn in
the "Drawing Area".4) Within the drawing area, users can left-click to draw up a part of the
curve; right-click to display all curves; flip the mouse wheel to zoomin/out the curve; and move the cursor onto the curve to read values of apoint.
5) Click "Back" to exit curve operation.8、 Deleting a project
1) If the "Project File Bar" is available, users can click "Delete" or pressthe "Delete" button through a keyboard to delete selected files.
2) This operation will delete the project and all its curve files.9、 Deleting a curve
1) If the "Curve File Bar" is available, users can click "Delete" or pressthe "Delete" button through a keyboard to delete selected files.
2) This operation will delete the selected file. Meanwhile, corresponding- 25 -
statistical reports will be updated. 10、Printing a curve
1) Open a project.2) Click "Test Curve" in the "Switch Bar".3) Double-click a desired curve file in the "Curve File Bar".4) Click "Print" to print the curve displayed in drawing area.
11、Printing a statistical report 1) Open a project.2) Click "Statistical Report" in the "Switch Bar".3) Click "Print" to print the Statistical Report of the project.
12、Export data Click “export data” can export the force value at the time get from historical test project and save a “*.xls” file.
Maintenance and After-Sales Service
1、 Use soft dry cloth for cleaning the product. The cloth must be wetted in cleaner water and dried first before rubbing off dusts and stains. Do not use volatile chemicals, for example, volatile oils, diluents, and alcohols.
2、 Make sure to control force during using or moving of the product. 3、 Do not disassemble, repair, or change the product by yourself. 4、 In case of a fault, contact the local shop or the manufacturer. 5、 Upon the warranty date, provided that the product is under normal use and
has no damage, if it is found quality problems within one month, users can go for the local shop or the manufacturer for replacement of the same specifications against the original invoice, warranty, and intact package. The warranty period and clauses of the replacement inherit the original product.
6、 Upon the purchase date, provided that the product is under normal use, if it is found a non-man-made fault (faults that are caused because users disassemble the product or have the product maintained by a third party are excluded from the warranty range) within one year, users can go for the local
- 26 -
shop for free maintenance against the original invoice and warranty. Warranty period of batteries is 3 months.
7、 The warranty clauses of this product only apply to products that are sold within China. If your product has exceeded the product replacement period even the warranty period, contact the local shop or the manufacturer for maintenance service. Maintenance service will be offered at users’ expense.
Battery Use and Maintenance
This product is configured with a 1600mAh 6V Ni-Hi rechargeable battery group. If it is fully charged, the product can be running uninterruptedly for 10 hours. While being shut down, the battery group enables the product last for 3 months. During use of this product, pay attention to the battery level at the right upper corner of the screen. In case of power shortage, use the delivered DC12V/1000mA power adapter to charge the product. It will be fully charged within 8 ~ 10 hours. Remove the power adapter immediately after the product prompts full charge. Otherwise, longtime charging may cause the battery group to overheat, burning circuits or resulting in accidents. Precautions: 1、 Recharging is recommended only after the batteries are completely used up.
This helps eliminate battery memory. 2、 Frequent charging or longtime charging will shorten service life of the
batteries. 3、 The product can be used for test in charge mode. Long-term not work need
charging regularly (to avoid battery invalid) 4、 In normal cases, the batteries can be charged 500 times. 5、 Battery warranty period: 3 months.
- 27 -
Packing List (for Embedded Products)
No. Name Qty. 1 Force gauge 1 2 Power adapter 1 3 Head accessory 5 4 Prolonged rod 1 5 Warranty 1 6 Use guide 1 7 USB line 1 8 Software setup disk 1
Packing List (for External Products)
No. Name Qty. 1 Force gauge 1 2 Power adapter 1 3 Sensor connector 1 4 Warranty 1 5 Use guide 1 6 USB line 1 7 Software setup disk 1
Load Cell Systems reserves the right to change specifications without notice. ©2018
Web: https://loadcellsys.com
Email: [email protected]
Phone: 607-426-1467