33
Guided Consolidation Product Support Engineering VMware Confidential

Guided Consolidation Product Support Engineering VMware Confidential

Embed Size (px)

Citation preview

Page 1: Guided Consolidation Product Support Engineering VMware Confidential

Guided Consolidation

Product Support Engineering

VMware Confidential

Page 2: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 2

Module 2 Lessons

Lesson 1 – vCenter Server High Availability

Lesson 2 – vCenter Server Distributed Resource Scheduler

Lesson 3 – Fault Tolerance Virtual Machines

Lesson 4 – Enhanced vMotion Compatibility

Lesson 5 – DPM - IPMI

Lesson 6 – vApps

Lesson 7 – Host Profiles

Lesson 8 – Reliability, Availability, Serviceability ( RAS )

Lesson 9 – Web Access

Lesson 10 – vCenter Server Update Manager

Lesson 11 – Guided Consolidation

Lesson 12 – Health Status

Page 3: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 3

Module 2-11 Lessons

Lesson 1 – Overview of Guided consolidation

Lesson 2 – Guided Consolidation Prerequisites

Lesson 3 – Guided Consolidation Settings

Lesson 4 – Finding and Analyzing Physical Systems

Lesson 5 – Viewing analysis Results

Lesson 6 – Converting Physical Hosts to Virtual Machines

Lesson 7 – Troubleshooting Guided Consolidation

Page 4: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 4

Guided Consolidation

Guided Consolidation, recommended for smaller IT environments, enables you to streamline your datacenter by moving business applications, spread across multiple disparate physical systems, into a centrally managed virtual environment.

In the virtualized environment, the physical systems that run your business applications are transformed into virtual machines.

Multiple virtual machines can be hosted on a single physical system, enabling more efficient use of computing resources.

Page 5: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 5

Guided ConsolidationConsolidating your datacenter involves the following process:

Find – You search for and select the physical systems in your datacenter that you want analyzed.

Analyze – Selected physical systems are analyzed and performance data on each selected system is collected. Generally, the longer the duration of the analysis phase the higher the confidence in the vCenter Server’s recommendations.

Consolidate – Performance data is compared to the resources available on the virtual machine host systems. The selected physical systems are converted to virtual machines and imported into vCenter Server on the recommended hosts where they are managed along with other components of your virtual environment.

Page 6: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 6

Consolidation PrerequisitesEnsure that the following prerequisites are met:

Ensure that the Converter Enterprise and Guided Consolidation extensions are installed and enabled in the vSphere Client.

At least one datacenter inventory object exists.

At least one host is registered with vCenter Server.

Consolidation services require local administrator privileges on the vCenter Server.

The collector service must be run with local administrator privileges.

The account used must also be granted the Logon as service privilege.

If Active Directory is deployed on your network, the credentials used to run consolidation services must also have sufficient privileges to query the Active Directory database.

Consolidation services also require administrator access to the systems selected for analysis. The collector service uses these credentials to connect to and retrieve configuration and performance data from the physical systems under analysis.

Page 7: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 7

About Consolidation Services

Consolidation services can be installed together with vCenter Server, or can be installed on a separate host.

For best performance, install Consolidation services on a separate host.

Page 8: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 8

About Consolidation Services

Guided Consolidation include the following services:

vCenter Collector ServiceDiscovers domains and systems within domains. Collects performance data on those systems.

vCenter Provider ServiceHelper service to vCenter Collector Service. Communicates with target systems and passes the data back to vCenter Collector Service.

vCenter Guided ConsolidationCoordinates all communication among Guided Consolidation components. Saves the performance data collected by the vCenter Collector Service. Analyzes the data and generates placement recommendations. Also communicates with vCenter Server to perform conversion.

Page 9: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 9

Specify Consolidation Settings

The first time you use the Consolidation feature, you are prompted to specify consolidation settings

The system‐level credentials are used by vCenter Server to access the systems selected for analysis

The configured default system‐level credentials can be overridden

When adding systems for analysis, you have the option to specify the credentials you want to use for the selected systems.

At anytime, you can specify the credentials you want to use for systems you select in the Analysis tab.

Page 10: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 10

Specify Consolidation Settings

To specify consolidation settings

1. Select Home -> Guide Consolidation -> Configuration -> Default System Credentials tab.

2. Click Change

Default System Credentials – Used to access systems that are selected for analysis but for which no administrator credentials are specified.

Page 11: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 11

Specify Consolidation Settings

3. Enter a domain‐qualified user name (for example, DOMAIN\username) and password.

4. Confirm the password and click OK.

Page 12: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 12

Specify Consolidation Settings

5. Click Add in the Active Domains panel

Guided Consolidation discovers the systems in the domains selected on a daily basis and updates the containment information

6. Select the Domain from the List and click OK.

Page 13: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 13

Specify Consolidation Settings

The Health Status shows the components that are required by the Guided Consolidation Service

Page 14: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 15

Find and Analyze Physical Systems

To find physical systems in your datacenter

1. Access the Add to Analysis dialog box by using one of the following methods:

In the Getting Started tab, click Analyze physical computers for consolidation.

In the Analysis tab, click Start Analysis.

Page 15: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 16

Find and Analyze Physical Systems

2. Select one of the following options:

Manually specify the computers to consolidate

Select the computers to consolidate by domains

Page 16: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 17

Find and Analyze Physical Systems3. If you chose to manually specify

systems, provide computer names, IP addresses, a range of IP addresses, or path to a file that contains the computer names or IP addresses of the systems you want according to the following rules:

Separate multiple computer names, or IP address, with a comma.

Multiple IP ranges are not permitted.

If you chose to use a file, each computer name or IP address must be on a separate line in the file. The file must be accessible to the VI Client.

Click Add to Analysis.

Page 17: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 18

Find and Analyze Physical Systems

4. If you chose to select systems by domain, select the systems you want to analyze.

You can optionally filter the list of systems by selecting filters and entering your criteria into the text field. You can turn filters on and off by clicking the down arrow to the left of the text box. You can also sort the list by clicking on column headings.

5. Click Add to Analysis.

Page 18: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 19

Find and Analyze Physical Systems

6. Select whether you want to use the configured default system‐level administrator credentials, or whether you want to supply a different set of credentials. If you chose override the default credentials, ensure that you enter a domain‐qualified user name (for example, DOMAIN\username) and password.

7. Click OK.

Page 19: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 20

Find and Analyze Physical Systems

The Physical Computer is now added to the List being analyzed

After some time ……

Page 20: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 21

Viewing Analysis Results

Analysis results are displayed in the Analysis tab. When analysis is complete, the following information is displayed:

Physical Computer – Displays the host name of the physical system being analyzed or imported.

CPU Info – Displays the number of CPUs and their clock speed.

Memory Info – Displays the amount of RAM on the system.

Status – Displays the progress of the analysis.

Confidence – Indicates the degree to which vCenter Server is able to gather performance data about the system and how good a candidate the system is based on the available data.

CPU Usage – Displays the system’s average CPU usage over time.

Memory Usage – Displays the system’s average memory usage over time.

Page 21: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 22

About the Confidence Metric

One important metric displayed in the Analysis tab is the Confidence metric.

During the analysis phase, performance data about each selected system is collected.

This data is compared to host resources to determine a recommendation for each candidate.

The recommendation indicates how well suited, based on the collected data, a candidate is to a particular virtual machine host system

Confidence refers to the reliability of the recommendation and it is a function of the duration of the analysis.

Recommendations based on longer periods of analysis – and therefore more performance data – receive a higher level of confidence.

Page 22: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 23

Consolidating Candidates

After you have analyzed your datacenter, you are ready to convert candidates to virtual machines.

In this phase, you select the systems you want to convert

vCenter Server selects appropriate destinations and configuration parameters for each resultant virtual machine.

If more than one virtual machine host is available, you can select the host you want.

NOTE It is highly recommended that you virtualize one candidate at a time.Consolidating multiple candidates simultaneously could cause all virtualization operations to fail if the host does not contain an adequate amount of storage space

Page 23: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 32

About Disk Resizing

During the conversion process, physical disks are typically resized to conserve space on the datastore while providing room for growth on the resultant virtual disk.

The following formula is used to resize converted disks:

Amount of space used on physical disk * 1.25 = resultant virtual disk size

Virtual disks can not be smaller than 4GB.

Page 24: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 37

Consolidating Candidates Manually

Choose which options of the guest operating system you would like to customize of Virtual Machine Install VMware Tools

Customize the identity of the Virtual Machine

Remove System Restore Checkpoints

Page 25: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 38

Customizing the identity of the VM

If the Customize the identity of the Virtual Machine is greyed out, you need to copy the SYSPREP files to the relevant location on the VMware vCenter Server

Page 26: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 43

Troubleshooting Consolidation

Guided Consolidation tasks are resource intensive. If you notice a negative impact on vCenter Server, consider the following:

Guided Consolidation caches information about discovered systems, and a very large cache can negatively impact vCenter Server performance. Do not run Guided Consolidation against more than 20,000 systems.

Up to 500 (or 100 if Guided Consolidation is collocated with vCenter Server) systems can be simultaneously analyzed. If you select more than five hundred systems, systems will be added, in the order they appear, until the maximum number of systems is reached.

Page 27: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 44

Troubleshooting Consolidation

Use the following options to remedy performance issues:

Disable consolidation and continue to run the collector service. This method prevents consolidation tasks from starting, but does not stop the collector service from gathering data.

Disable consolidation, and stop and disable the collector service. This method prevents consolidation tasks from starting, and stops the collector service from gathering data. The collected data is not destroyed and can be used if the service is started again.

Uninstall the collector service. This method removes Guided Consolidation, and the data it has collected will no longer be usable.

Page 28: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 45

Disable Consolidation

To disable consolidation

1. Select Administration > vCenter Server Settings ….

2. Select Advanced Settings.

3. Enter the following in the Key field: dontStartConsolidation

4. Enter the following in the Value field: true

5. Click Add

6. Restart the vCenter Server.

Page 29: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 46

Disable the Collector ServiceTo disable the collector service

1. Open the Services control panel.

2. Stop the VMware Capacity Planner Services. VMware Capacity Planner Collector & VMware Capacity Planner Provider

3. Disable the VMware Capacity Planner Service.

Page 30: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 48

Location of Guided Consolidation Logs

VMware Capacity Planner Collector Logs

D:\Program Files\VMware\Infrastructure\Guided Consolidation Server\Collector\CollectorServerHost\collector.log

VMware Capacity Planner Provider Logs

D:\Program Files\VMware\Infrastructure\Guided Consolidation Server\Collector\ProviderServerHost\provider-server.log

Page 31: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 49

Location of VMware vCenter Converter Logs

VMware vCenter Converter logs can be found at C:\Documents and Settings\All Users\Application Data\VMware\VMware Converter Enterprise\Logs as vmware-converter-server*.*

VMware vCenter Converter Client logs can be found at C:\Documents and Settings\Administrator.VI40\Local Settings\Application Data\VMware\VMware VMware Converter Enterprise\Logs as vmware-converter-client*.*

WARNING: Logs are stored on a temporary basis, and should be retrieved as soon as possible.

Page 32: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 50

Lesson 2-11 Summary

Understand Guided consolidation

Analyzing Physical Systems

Converting Physical Systems to Virtual Machines

Learn how to troubleshoot Guided Consolidation

Page 33: Guided Consolidation Product Support Engineering VMware Confidential

VI4 - Mod 2-11 - Slide 51

Lesson 2-11 – OPTIONAL Lab 1

Optional Find and Analyze Physical Systems

Convert Physical Systems to Virtual Machines

Troubleshoot Guided Consolidation