Geothermal Vaults and HDPE Structures
What is a Structure?Valve Vault ManholePump StationCatch BasinJunction BoxWet WellSumpKnock Out PotValve BoxTankEtcAll of these have been made from HDPE by ISCO Industries
For: Water/SewerIndustrialLandfillIrrigationGeothermal
Typical HDPE Structures
Geothermal Structures
Advantages of HDPE StructuresThey are the same as the pipe:ToughFlexibleLeak-freeLightweight and easy to installCorrosion & Chemically resistantHDPE structures can be prefabricated for installation savings and higher quality.
Design ElementsHeader/Circuit size# of CircuitsLocation of CircuitsCircuit ValvesHeader ValvesManwayMisc
Header and Circuit configurationHeader size is typically 4-10 which does not affect cylinder diameter# of circuits and location of circuits will affect length
Location of CircuitsStandard configuration is for circuits to come out both sides of vaultsCan offer circuits to exit one sideCan create unbalanced number from one side to other
Valves for VaultStandard Valves typically butterfly valvesBalancing valves and circuit setters availableBall valves for purge ports only- not recommended for circuitsTypically provide butterfly valves for main shutoffNew Bypass recirculation
Manway designStandard Bolted Cover H-20 load bearing availableVariable diameter with 28 OD standardHeight can be specified- shipping concerns become a factor with excessive height
Miscellaneous ItemsLadder (standard)P/T ports (standard)LightsElectrical outletsDrain Valves for main/header
Miscellaneous ItemsSumpPumpPressure GaugesThermometersDrain Valve for circuitsKeep in mind this vault is not a mechanical room.
Factory Tested for LeaksHeader and Circuit piping hydrostatically tested to 100 psiStructure tested with 2-3 psi of air to verify vault sealed from groundwater and weather.Misc items like sump/pump become unessential if liquid in interior comes from upset conditions, not standard conditions.
Installation ValueLightweighttypically less than 5000 lbs Maximum of 15000 lbs for 36 circuits
Installation ValueFast installCompared to alternate choices, time is measured in hours verses days/weeks
Installation ValueSimple and Reliable ConnectionsCircuits and headers are connected to stubs on vault with Butt Welding or Electrofusion
Years of Design and Fabrication experience can help prevent installation and operation headaches.Choose an ISCO Circuitmaker Vault for reliable strength and leak free performance!