Genesis FS Plusfloor standing condensing boiler
MODELS
OUTPUT(kW)
281 - 832
280
420
570
840
10:1Modulation
Turndown
10yrHeat Exchanger
Warranty6
NOx Class
Genesis FS PlusThe Genesis FS Plus floor standing boiler is available in a range of 4 models from 280 - 840kW, with a highly durable stainless steel heat exchanger offering thermal efficiency up to 108% net. The Genesis FS boiler has a modulation range up to 10:1, with a small footprint which makes it suitable for installation in areas with space constraints. The boiler has an intelligent control system which can cascade up to 16 boilers in a modular configuration.
I N T R O D U C T I O N
key featuresStainless steel heat exchanger
Cascade installations up to 16 boilers
Class 6 NOx emissions
High modulation ratio up to 10:1
0-10V control
Compact dimensions
Stainless steel internal pipework
Efficiency of up to 108% net
Achieves 2 BREEAM credits
10 year warranty* on heat exchanger2 year warranty* on parts
warranty
Stainless Steel BIM
Drawings
*subject to Terms & Conditions
MODELS
280
420
570
840
Nat Gas & LPG
S I N G L E B O I L E R D I M E N S I O N S
HeightWidthDepthAir inletChimney connectionHeating return connectionHeating flow connectionGas connectionCondensate drain
280 420
1970
761
1594
150
180
DN80
DN80
1½
26.7
1970
761
1594
150
200
DN80
DN80
1½
26.7
mm
mm
mm
mm
mm
inches
inches
inches
mm
570 840
1970
864
1848
250
200
DN80
DN80
DN65
26.7
1970
864
1848
250
250
DN80
DN80
DN65
26.7
Gas mixing system with constant air/gas modulation
Stainless steel heat exchanger
Sealed air duct (air filter optional)
Condensate drain dish
internal structure
Gas Return Flow
Width
Hei
ght
Depth
FRONT VIEW PLAN VIEW REAR VIEW
T E C H N I C A L D ATA
pow
er
Maximum boiler output (80-60°C) - NG (G20)Maximum boiler output (50-30°C) - NG (G20)Maximum boiler output (80-60°C) - LPG (G31-37mbar)Maximum boiler output (50-30°C) - LPG (G31-37mbar)Minimum boiler output (80-60°C) - NG (G20)Minimum boiler output (50-30°C) - NG (G20)Minimum boiler output (80-60°C) - LPG (G31-37mbar)Minimum boiler output (50-30°C) - LPG (G31-37mbar)Maximum boiler input netHeat efficiency (50-30°C) – maximum outputStandby lossesModulationBuilding regulations Part L seasonal efficiency (Non Domestic Building) - NG
Building regulations Part L seasonal efficiency (Non Domestic Building) - LPG
280 420 570 840MODEL
769.8831.5769.8816.186.696.7
190.4209.5792.0105.00.0068.8:195.797.8
258.0281.6258.0276.825.027.964.070.0265.0106.30.00610.2:195.797.8
388.1421.3390.0419.039.843.196.0105.0401.2106.90.0079.6:195.597.6
516.0567.0515.0556.064.571.5
120.0132.0530.0107.00.0087.9:195.597.6
kW
kW
kW
kW
kW
kW
kW
kW
kW
%
kW
Ratio
% gross
% gross
Dry weight 578 658 835 934Kg
gas
Gas flow rate, NG (G20) - maximumGas flow rate, LPG (G31-37mbar) - maximumMaximum gas inlet pressure – NG (G20)Maximum gas inlet pressure – LPG (G31-37mbar)Nominal gas inlet pressure – NG (G20)Nominal gas inlet pressure – LPG (G31-37mbar)Minimum gas inlet pressure – NG (G20)Minimum gas inlet pressure – LPG (G31-37mbar)
77.831.0254520371725
26.210.2254520371725
40.415.0254520371725
52.120.7254520371725
m³/h
m³/h
mbar
mbar
mbar
mbar
mbar
mbar
Electrical supply Power consumption - maximumPower consumption - minimum Run current - maximum
elec
tric
400/3/501.5410.0714.6
230/1/500.4620.041
2.4
230/1/500.5780.050
3.0
230/1/500.6830.056
3.5
44421.53.490.86.090
39016.22.670.86.090
Water contentSystem design flow rate (20°CΔT)Water side pressure loss (20°CΔT)Minimum water pressureMaximum water pressureMaximum flow temperature
hydr
aulic
29110.81.860.86.090
56331.56.070.86.090
litres
m³/h
kPa
bar
bar
°C
Flue gas temperature at 80/60°CFlue gas temperature at 50/30°CMax. flue gas pressureMass flow rate of flue gassesMax. condensate volumeDry NOx emission (0% excess O�)
flue
74.851.4200327
100.829.0
69.445.7200111
33.634.2
72.045.020016450.430.0
72.344.320021778.224.0
°C
°C
Pa
g/s
kg/h
mg/kWh
Fused supply requirement of (Amps):
kW
kW
A
4 per phase4 5 6
S Y S T E M S C H E M AT I C S
5
5
5
5
23B
23B
GENESIS
GENESIS
GENESIS
GENESIS
22
22
22
22
sealed system with plate heat exchanger
sealed system with low loss header
3
3
H.C. Heating circuitD.H.W. Domestic hot waterA Primary return/drainB DHW cold water supply1. Primary flow2. Primary return3. Outside temperature sensor4. Boiler pump5. Expansion vessel6. Safety group (safety valve, air vent - air purge, manometer)7. Plate heat exchanger/low loss header8. Air vent 9. DHW primary pump10. DHW storage tank
11. DHW storage tank temperature sensor12. Check valve13. Water pressure sensor14. Room unit/room thermostat15. Mixing valve16. Consumers17. Cascade return sensor18. DHW circulation pump (with timer)19. HC pump20. System flow temperature sensor21. HC1, HC2, HC3 temperature sensor22. Strainer23. System pressure manager