9
20WIN 05.02.18 As shown JC D Proposed 2 Storey Dwelling Paul Pavli and Laura Munoz No. 20 Win-Malee Street, Hadfield Rev. Date Description DATE : SCALE : DRAWN : CHECKED : SHEET: OF CLIENT : ADDRESS : DRAWING TITLE : Rev. A M E N D M E N T S REG No. : J.Campbell A 05.02.18 Issued as preliminary design sketches DPAD29975 B 12.02.18 Re-Issued as preliminary design sketches/Elevations C 19.02.18 Revised to suit clients feedback for final approval D 02.03.18 Issued for council approval/construction plans The attached design is copyright to 3rdDimension Developments Pty. Ltd. and can only be used in ANY FORM with a written/or contractual agreement signed by the Director. Important Notes COPYRIGHT 3rdDimension Developments Pty. Ltd If there are any outstanding accounts in relation to this documentation then any copyright usage will be voided. A1 1 9 Project: No.20 Win-Malee Street, Hadfield. Vic Address: Proposed 2 Storey Dwelling GENERAL NOTES § All materials and work practices shall comply with, but not limited to the Building Regulations 2006, the National Construction Code Series 2016 Building Code of Australia Vol 2 and all relevant current Australian Standards (as amended) referred to therein. § Unless otherwise specified, the term BCA shall refer to National Construction Code Series 2016 Building Code of Australia Volume 2. § All materials and construction practice shall meet the Performance Requirements of the NCCA. Where an alternative solution is proposed then prior to implementation or installation it first must be assessed and approved by the Relevant Building Surveyor as meeting the Performance Requirements of the NCCA. § Glazing including safety glazing shall be installed to a size, type and thickness so as to comply with: - TO COMPLY WITH AS1288 and AS 2047-2014/Amdt 1-2016 -BCA Part 3.6 for Class 1 and 10 buildings within a design wind speed of not more than N3, and -NCC 2014 BCA Vol 1 Part B1.4 for Class 2 to 9 buildings § Waterproofing of wet areas, being bathrooms, showers, shower rooms, laundries, sanitary compartments and the like shall be provided in accordance with AS 3740-2010: Waterproofing of Wet Areas in Residential Buildings. § These Drawings shall be read in conjunction with any House Energy Rating (HERS) report and shall be constructed in accordance with the stamped plans endorsed by the accredited Thermal Performance Assessor without alteration ALL STAIRS § Step sizes (other than for spiral stairs) to be: - Risers (R) 190mm maximum and 115mm minimum - Going (G) 355mm maximum and 240mm minimum - 2R + 1G = 700mm maximum and 550mm minimum - with less than 125mm gap between open treads § All treads, landings and the like to have non slip finish or suitable non-skid strip near edge of nosing. § Provide balustrades where change in level exceeds 1000mm above the surface beneath landings, ramps and/or treads. Balustrades (other than tensioned wire balustrades) to be: - 1000mm min. above finished surface level of balconies, landings or the like, and - 865mm min. above finished surface level of stair nosing or ramp, and - vertical with less than 125mm gap between, and - any horizontal element within the balustrade between 150mm and 760mm above the floor must not facilitate climbing where changes in level exceeds 4000mm above the surface beneath landings, ramps and/or treads. Wire balustrade construction to comply with NCC Part 3.9.2.3 for Class 1 and 10 Buildings and NCC 2016 Volume 1 Part D2.16 for other Classes of Buildings. § Top of hand rails to be minimum 865mm above stair nosing and floor surface of ramps. § Window sizes nominated are nominal only. Actual size may vary according to manufacturer. Windows to be flashed all around. Where the building (excludes a detached Class 10) is located in a termite prone area the area to underside of building and perimeter is to be treated against termite attack. § Concrete stumps: up to 1400mm long to be 100mm x 100mm (1 No. H.D. Wire) 1401mm to 1800mm L to be 100mm x 100mm (2 No. H.D. Wires) 1801mm to 3000mm L to be 125mm x 125mm (2 No. H.D.Wires) 100mm x 100mm stumps exceeding 1200mm above ground level to be braced where no perimeter base brickwork provided. § Insulation (Thermal) as per part 3.12 of the BCA : § - REFER TO ENERGY REPORT § For buildings in marine or other exposure environments shall have masonry units, mortar and all built in components and the like complying with the durability requirements of Table 4.1 of AS4773.1-2010 'Masonry in small buildings' Part 1: Design § All stormwater to be taken to the legal point of discharge to the Relevant Authorities approval. § These drawings shall be read in conjunction with all relevant structural and all other consultants drawings/details and with any other written instructions issued in the course of the contract. § Site plan measurements in metres - all other measurements in millimetres u.n.o. § Figured dimensions take precedence over scaled dimensions. § The Builder shall take all steps necessary to ensure the stability and general water tightness of all new and/or existing structures during all works. § The Builder and Subcontractors shall check and verify all dimensions, setbacks, levels and specifications and all other relevant documentation prior to the commencement of any works. Report all discrepancies to this office for clarification. § Installation of all services shall comply with the respective supply authority requirements. § The Builder and Subcontractor shall ensure that all stormwater drains, sewer pipes and the like are located at a sufficient distance from any buildings footing and/or slab edge beams so as to prevent general moisture penetration, dampness, weakening and undermining of any building and its footing system. § These plans have been prepared for the exclusive use by the Client of 3rdDimension ('The Designer') for the purpose expressly notified to the Designer. Any other person who uses or relies on these plans without the Designer's written consent does so at their own risk and no responsibility is accepted by the Designer for such use and/or reliance. § The approval by this office of a substitute material, work practice, variation or the like is not an authorisation for its use or a contract variation. Any said variations must be accepted by all parties to the agreement and where applicable the Relevant Building Surveyor prior to implementing the said variation. STORMWATER - TO COMPLY WITH AS3500 90mm DIA. Class 6 UPVC stormwater line laid to a minimum grade of 1:100 and connected to the legal point of stormwater discharge. Provide inspection openings at 9000mm C/C and at each change of direction. The cover to underground stormwater drains shall be not less than - 100mm under soil - 50mm under paved or concrete areas - 100mm under unreinforced concrete or paved driveways - 75mm under reinforced concrete driveways SITE ENVIRONMENT DESIGN INFORMATION Design gust wind speed / wind classification Building tie-downs to be provided in accordance with AS1684-2014 for an assumed design gust wind speed / wind classification of N1 (subject to confirmation on site by Relevant Building Surveyor at first inspection) refer to AS1684 for construction requirements. DRAWING SCHEDULE : (Permit) * A2 - PROPOSED SITE PLAN * A1 - COVER NOTES * A3 - FLOOR PLAN-GROUND * A4 - FLOOR PLAN-FIRST * A5 - ELEVATIONS 1 * A6 - ELEVATIONS 2 * A7 - SECTION AND DETAILS * A8 - ELECTRICAL PLAN-GROUND * A9 - ELECTRICAL PLAN-FIRST

GENERAL NOTES Proposed 2 Storey Dwelling No.20 Win ......2018/06/20  · AS4773.1-2010 'Masonry in small buildings' Part 1: Design All stormwater to be taken to the legal point of

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • 20WIN05.02.18As shownJC

    D

    Proposed 2 Storey Dwelling

    Paul Pavli and Laura Munoz

    No. 20 Win-Malee Street, HadfieldRev. Date Description

    DATE :SCALE :DRAWN :CHECKED :

    SHEET:

    OF

    CLIENT :

    ADDRESS :

    DRAWING TITLE :

    Rev.

    A M E N D M E N T S

    REG No. :J.Campbell

    A 05.02.18 Issued as preliminary design sketchesDPAD29975B 12.02.18 Re-Issued as preliminary design sketches/Elevations

    C 19.02.18 Revised to suit clients feedback for final approvalD 02.03.18 Issued for council approval/construction plans

    ► The attached design is copyright to 3rdDimension DevelopmentsPty. Ltd. and can only be used in ANY FORM with a written/orcontractual agreement signed by the Director.

    Important Notes

    COPYRIGHT 3rdDimension Developments Pty. Ltd

    ► If there are any outstanding accounts in relation to this documentationthen any copyright usage will be voided. A11 9

    Project:

    No.20 Win-Malee Street,Hadfield. Vic

    Address:

    Proposed 2 StoreyDwelling

    GENERAL NOTES

    § All materials and work practices shall comply with, but not limited to theBuilding Regulations 2006, the National Construction Code Series

    2016 Building Code of Australia Vol 2 and all relevant current

    Australian Standards (as amended) referred to therein.

    § Unless otherwise specified, the term BCA shall refer to NationalConstruction Code Series 2016 Building Code of Australia Volume 2.

    § All materials and construction practice shall meet the PerformanceRequirements of the NCCA. Where an alternative solution is

    proposed then prior to implementation or installation it first must be

    assessed and approved by the Relevant Building Surveyor as meeting

    the Performance Requirements of the NCCA.

    § Glazing including safety glazing shall be installed to a size, type andthickness so as to comply with:

    -TO COMPLY WITH AS1288 and AS 2047-2014/Amdt 1-2016

    -BCA Part 3.6 for Class 1 and 10 buildings within a design wind

    speed of not more than N3, and

    -NCC 2014 BCA Vol 1 Part B1.4 for Class 2 to 9 buildings

    § Waterproofing of wet areas, being bathrooms, showers, showerrooms, laundries, sanitary compartments and the like shall be

    provided in accordance with AS 3740-2010: Waterproofing of Wet

    Areas in Residential Buildings.

    § These Drawings shall be read in conjunction with any House EnergyRating (HERS) report and shall be constructed in accordance with the

    stamped plans endorsed by the accredited Thermal Performance

    Assessor without alteration

    ALL STAIRS

    § Step sizes (other than for spiral stairs) to be:- Risers (R) 190mm maximum and 115mm minimum

    - Going (G) 355mm maximum and 240mm minimum

    - 2R + 1G = 700mm maximum and 550mm minimum

    - with less than 125mm gap between open treads

    § All treads, landings and the like to have non slip finish or suitablenon-skid strip near edge of nosing.

    § Provide balustrades where change in level exceeds 1000mm abovethe surface beneath landings, ramps and/or treads. Balustrades (other

    than tensioned wire balustrades) to be:

    - 1000mm min. above finished surface level of balconies, landings or

    the like, and

    - 865mm min. above finished surface level of stair nosing or ramp, and

    - vertical with less than 125mm gap between, and

    - any horizontal element within the balustrade between 150mm and

    760mm above the floor must not facilitate climbing where changes in

    level exceeds 4000mm above the surface beneath landings, ramps

    and/or treads.

    Wire balustrade construction to comply with NCC Part 3.9.2.3 for

    Class 1 and 10 Buildings and NCC 2016 Volume 1 Part D2.16 for

    other Classes of Buildings.

    § Top of hand rails to be minimum 865mm above stair nosing and floorsurface of ramps.

    § Window sizes nominated are nominal only. Actual size may varyaccording to manufacturer. Windows to be flashed all around.

    Where the building (excludes a detached Class 10) is located in a

    termite prone area the area to underside of building and perimeter is to

    be treated against termite attack.

    § Concrete stumps:up to 1400mm long to be 100mm x 100mm (1 No. H.D. Wire)

    1401mm to 1800mm L to be 100mm x 100mm (2 No. H.D. Wires)

    1801mm to 3000mm L to be 125mm x 125mm (2 No. H.D.Wires)

    100mm x 100mm stumps exceeding 1200mm above ground level to be

    braced where no perimeter base brickwork provided.

    § Insulation (Thermal) as per part 3.12 of the BCA :§ - REFER TO ENERGY REPORT

    § For buildings in marine or other exposure environments shall havemasonry units, mortar and all built in components and the like

    complying with the durability requirements of Table 4.1 of

    AS4773.1-2010 'Masonry in small buildings' Part 1: Design

    § All stormwater to be taken to the legal point of discharge to theRelevant Authorities approval.

    § These drawings shall be read in conjunction with all relevant structuraland all other consultants drawings/details and with any other written

    instructions issued in the course of the contract.

    § Site plan measurements in metres - all other measurements inmillimetres u.n.o.

    § Figured dimensions take precedence over scaled dimensions.

    § The Builder shall take all steps necessary to ensure the stability andgeneral water tightness of all new and/or existing structures during all

    works.

    § The Builder and Subcontractors shall check and verify all dimensions,setbacks, levels and specifications and all other relevant

    documentation prior to the commencement of any works. Report all

    discrepancies to this office for clarification.

    § Installation of all services shall comply with the respective supplyauthority requirements.

    § The Builder and Subcontractor shall ensure that all stormwater drains,sewer pipes and the like are located at a sufficient distance from any

    buildings footing and/or slab edge beams so as to prevent general

    moisture penetration, dampness, weakening and undermining of any

    building and its footing system.

    § These plans have been prepared for the exclusive use by the Client of3rdDimension ('The Designer') for the purpose expressly notified to the

    Designer. Any other person who uses or relies on these plans without

    the Designer's written consent does so at their own risk and no

    responsibility is accepted by the Designer for such use and/or reliance.

    § The approval by this office of a substitute material, work practice,variation or the like is not an authorisation for its use or a contract

    variation. Any said variations must be accepted by all parties to the

    agreement and where applicable the Relevant Building Surveyor prior

    to implementing the said variation.

    STORMWATER

    - TO COMPLY WITH AS3500

    90mm DIA. Class 6 UPVC stormwater line laid to a minimum grade of

    1:100 and connected to the legal point of stormwater discharge.

    Provide inspection openings at 9000mm C/C and at each change of

    direction.

    The cover to underground stormwater drains shall be not less than

    - 100mm under soil

    - 50mm under paved or concrete areas

    - 100mm under unreinforced concrete or paved driveways

    - 75mm under reinforced concrete driveways

    SITE ENVIRONMENT DESIGN INFORMATION

    Design gust wind speed / wind classification

    Building tie-downs to be provided in accordance with AS1684-2014 for

    an assumed design gust wind speed / wind classification of N1

    (subject to confirmation on site by Relevant Building Surveyor at first

    inspection) refer to AS1684 for construction requirements.

    DRAWING SCHEDULE : (Permit)

    * A2 - PROPOSED SITE PLAN* A1 - COVER NOTES

    * A3 - FLOOR PLAN-GROUND* A4 - FLOOR PLAN-FIRST* A5 - ELEVATIONS 1* A6 - ELEVATIONS 2* A7 - SECTION AND DETAILS* A8 - ELECTRICAL PLAN-GROUND* A9 - ELECTRICAL PLAN-FIRST

  • L.P.O.D.Legal point of discharge to beconnected to meet authoritiesrequirements & location

    CUT RL 1.310GARAGE FL 1.714

    CUT RL 1.400GROUND FL 1.800

    Garage Setback

    SW

    dra

    in

    Solar panelfor HWS

    PROPOSEDDWELLING

    // // // // // // // //

    LOT 36No.20320m²

    Clothesline

    W/TANK

    Roof Below

    S.P.O.S.

    Proposed exp. agg.concrete driveway

    and path(Gradient 1:7)

    DP

    GARAGE

    Proposed 2.0m(h)colorbond metal fence

    WIN-MALEE STREET

    276°16

    '16

    .5m

    186°48'30"24.84m

    Existingdouble

    concretecrossover

    R41.0m

    1.00

    0

    DwellingSetback

    PorchSetback

    Por.

    T.B.

    M.

    1.04

    0

    1.59

    0

    1.73

    0Wall on boundary

    1.75

    0

    1.35

    0

    1.25

    0

    1.65

    01.

    170

    R21.5m

    1.05

    0

    GF

    Offs

    et

    LOT 35(Vacant as at 2.03.18)

    SE

    WS

    EW

    ConcretePaving

    RWH& DP

    RWH& DP

    SEWER DETAILSSIZE: 150mmTYPE: PVE-NPDEPTH: 2.4mOFFSET: 1.0m

    DP

    // // //

    Proposed 1.2m(h)colorbond metal fence

    // // // // //

    //

    //

    //

    //

    //

    //

    //

    //

    //

    //

    //

    //

    6°48'00"13.41m

    Proposed 2.0m(h)

    colorbond metal fence

    0.92

    0 0.98

    0

    1.02

    0

    Shed 6m3

    SW

    dra

    in

    SW drain

    Box Gutter

    1.45

    0

    GF

    Offs

    et

    RearOffset

    3000L

    1.70

    0

    1.65

    0

    Proposed 2.0m(h)colorbond metal fence

    SE

    W

    Footpath

    Kerb and Channel

    Foot

    path

    Par

    king

    Bay

    0.95

    0

    1.53

    01.

    330

    Nature stripKe

    rb an

    d Cha

    nnel

    PIM

    BIA

    LC

    OU

    RT

    DP

    DP

    FFO

    ffset

    At pointOffset

    At pointOffset

    Indicative tree within frontsetback to be inaccordance with theMoreland TreePlanting Manual forResidential Zones, 2014.

    Length of wall on boundary

    20WIN05.02.18As shownJC

    D

    Proposed 2 Storey Dwelling

    Paul Pavli and Laura Munoz

    No. 20 Win-Malee Street, HadfieldRev. Date Description

    DATE :SCALE :DRAWN :CHECKED :

    SHEET:

    OF

    CLIENT :

    ADDRESS :

    DRAWING TITLE :

    Rev.

    A M E N D M E N T S

    REG No. :J.Campbell

    A 05.02.18 Issued as preliminary design sketchesDPAD29975B 12.02.18 Re-Issued as preliminary design sketches/Elevations

    C 19.02.18 Revised to suit clients feedback for final approvalD 02.03.18 Issued for council approval/construction plans

    ► The attached design is copyright to 3rdDimension DevelopmentsPty. Ltd. and can only be used in ANY FORM with a written/orcontractual agreement signed by the Director.

    Important Notes

    COPYRIGHT 3rdDimension Developments Pty. Ltd

    ► If there are any outstanding accounts in relation to this documentationthen any copyright usage will be voided.

    PROPOSED SITE PLAN Scale 1:200

    A22 9

    DEVELOPMENT

    320m²

    50%

    80m²Proposed Dwelling:

    Private Open space :

    % coverage:

    Total site area:

    Site coverage:

    Proposed dwelling 159m²

    TOTAL: 298m2 (32 sqrs)

    118.0m²Ground Floor:Proposed Dwelling Area

    Porch: 5.0m²134.0m²First Floor:

    SUMMARY

    Balcony: 5.0m²36.0m²Garage:

  • NOTE:2340mm(h) internal doors toall passage sets incl. robes

    NOTE:STAIR COATING TO ACHIEVEP3/R10 SLIP RESISTANCE

    Note:Duct riser for heating will need tobe allowed for once Duct layoutdesign has been provided frommanufacturer/Builder.

    concrete

    X

    X

    Beams toengineersdesign andspecifications

    Garage

    S

    Concrete

    Overheadcup'ds

    F/standing

    2157

    mm

    (h)x

    4810

    mm

    (w)

    Pan

    elift

    Gar

    age

    door

    MB

    Fren

    ch D

    oors

    FL- 1.714

    Por.

    720

    Dining

    Breakfast bar

    dwsnk

    up

    820

    But. P'try

    S

    820

    12345

    6

    Fireplace72

    0 C

    SD

    P

    Pdr

    V900

    820

    Rumpus

    Ref.

    Family

    Laminate cup'd

    Foyer

    Kitchen

    Void

    Linenunder stairs

    2057

    x365

    0

    2057x1200

    2057

    x850

    2057

    x850

    1457x1200

    1800

    x850

    1800

    x850

    1800

    x850

    1011

    121314

    Stairs7 8 9

    2057x1200

    820

    820

    820

    820

    Shelves

    Cup'd

    2057x1200

    RWH& DP

    NOTE:Rangehood to beducted externally

    Stairs tomanufacturersdesign andspecifications

    Gas DP

    Ove

    rall

    Rum

    pus

    1m(h) balustradeto NCCA reg.

    Overheadcup'ds

    Waterpointfor Ref.

    Wall on boundary(Gutter over brickwork)

    Bulkhead

    Overall

    FL- 1.800

    rumpus but. pantry

    Kitchen

    Carpet

    Overall

    fam

    ily

    P'd

    r

    Gar

    age

    opening

    Garage

    Family

    Porch

    Porch

    piers

    RWH& DP

    MWFo

    yer

    FL- 1.7

    Col

    umn

    Sta

    irs

    Ove

    rall 15

    16

    Pass./Stairs over

    P'drStairsFoyer

    Dining

    DP

    DP

    DP

    shelves fireplace Alcove

    Pas

    s./K

    itche

    nB

    ut. P

    antry

    gara

    ge

    column column

    fam

    ily/d

    inin

    g

    Bulkhead

    piers

    Rum

    pus

    HWS

    Beam to engineers designand specifications

    NOTE:Double glazed windows and doorsthroughout external walls of dwelling

    20WIN05.02.18As shownJC

    D

    Proposed 2 Storey Dwelling

    Paul Pavli and Laura Munoz

    No. 20 Win-Malee Street, HadfieldRev. Date Description

    DATE :SCALE :DRAWN :CHECKED :

    SHEET:

    OF

    CLIENT :

    ADDRESS :

    DRAWING TITLE :

    Rev.

    A M E N D M E N T S

    REG No. :J.Campbell

    A 05.02.18 Issued as preliminary design sketchesDPAD29975B 12.02.18 Re-Issued as preliminary design sketches/Elevations

    C 19.02.18 Revised to suit clients feedback for final approvalD 02.03.18 Issued for council approval/construction plans

    ► The attached design is copyright to 3rdDimension DevelopmentsPty. Ltd. and can only be used in ANY FORM with a written/orcontractual agreement signed by the Director.

    Important Notes

    COPYRIGHT 3rdDimension Developments Pty. Ltd

    ► If there are any outstanding accounts in relation to this documentationthen any copyright usage will be voided.

    GROUND FLOOR PLAN Scale 1:100

    A33 9

    CA

    B

    ELEVATIONS

    D

    NOTES:

    * ALL WATER CLOSETS TO HAVE REMOVABLEHINGES TO THE DOORS IF THERE IS LESSTHAN 1.2m CLEARANCE BETWEEN THECLOSET PAN AND THE DOORWAY.

    * ALL GLAZING TO BE INACCORDANCE WITH AS1288* SMOKE DETECTORS TO COMPLYWITH AS 3786 AND CONNECTED TOMAINS AND INTERCONNECTED.

    * CEILING FAN TO BE SWITCHEDON WITH LIGHT AS PER AUSTSTANDARDS

  • NOTE:2340mm(h) internal doors toall passage sets incl. robes

    NOTE:STAIR COATING TO ACHIEVEP3/R10 SLIP RESISTANCE

    Note:Duct riser for heating will need tobe allowed for once Duct layoutdesign has been provided frommanufacturer/Builder.

    WM

    TR.

    P

    L'dry

    Shr900

    x1200

    720

    bath

    BATH

    V195

    0

    P

    Stairs

    720

    wc

    1200

    x241

    0

    Balc. Dn12345

    Bed 2

    Void

    1800

    x850

    1800

    x850

    1800

    x850

    8 9 1011

    1213

    Bed 3

    820820

    Line

    n720

    Robe

    Rob

    e

    Bed 1

    820 Robe

    LINEN

    1200

    x850

    1800

    x850

    1800

    x850

    1200

    x241

    0

    Retreat/Guest

    820

    820

    V220

    0

    720

    Robe

    Rob

    e

    Robe

    DressingRoom

    Pass.

    141516

    1800x850

    Shr1200x1800

    WC

    Gla

    ss d

    oors

    DRY

    Optionaldoubledoors

    1200x6101450x1450

    1200

    x610

    Box Gutter

    X

    X

    600(w)

    820 Cav. SD 2/920 Mirr.SD

    DRY CUP'D1200(w)

    Wall on Boundary - Gutter on Brick - See Detail

    NOTE:First floor windows to have max.opening of 125mm to NCCArequirements

    fall

    FL-4.840

    RWH& DP

    fall

    1m(h

    ) bal

    ustra

    deto

    NC

    CA

    reg.

    1.5 Deg.FLATROOF

    BELOW

    RWH& DP

    DP

    DP

    DP

    DP

    6 7

    1m(h

    ) bal

    ustra

    deto

    NC

    CA

    reg.

    Carpet

    Carpet

    Carpet

    Carpet

    Carpet

    Carpet

    Ens.

    820

    820

    820

    820

    Bed 1 Ensuite

    2.1m(h) wallRobeDressing room Duct

    Bed 1 Laundry

    Window

    Ensuite

    Balc.

    Overall

    Overall

    Dressing room Retreat/GuestBed

    FlexiStair void

    2/82

    0 S

    D

    3/720 SD

    robe

    bed 3 bath wc robe bed 2

    pass. desk alcovebed 3

    Ove

    rall

    Ove

    rall

    2/820 SD

    Duc

    t/R

    obe

    Bed

    1D

    ress

    ing

    room

    Dre

    ssin

    g ro

    om

    Bed

    3R

    obe

    Bed

    3

    Ens

    uite

    Bed

    1

    Ens

    uite

    Laun

    dry

    Ret

    reat

    /Gue

    st

    Bed

    2

    Bed

    2

    Ret

    reat

    /Gue

    st/F

    lexi

    Pas

    s.Li

    n.R

    obe/

    WcBat

    h

    fallfall

    FlexiCarpet

    flexi

    bed 2

    Heating/Coolingduct riser

    Heating/Coolingduct riser

    robeductguestflexistairs

    balcony

    balustrade

    NOTE:Double glazed windows and doorsthroughout external walls of dwelling

    20WIN05.02.18As shownJC

    D

    Proposed 2 Storey Dwelling

    Paul Pavli and Laura Munoz

    No. 20 Win-Malee Street, HadfieldRev. Date Description

    DATE :SCALE :DRAWN :CHECKED :

    SHEET:

    OF

    CLIENT :

    ADDRESS :

    DRAWING TITLE :

    Rev.

    A M E N D M E N T S

    REG No. :J.Campbell

    A 05.02.18 Issued as preliminary design sketchesDPAD29975B 12.02.18 Re-Issued as preliminary design sketches/Elevations

    C 19.02.18 Revised to suit clients feedback for final approvalD 02.03.18 Issued for council approval/construction plans

    ► The attached design is copyright to 3rdDimension DevelopmentsPty. Ltd. and can only be used in ANY FORM with a written/orcontractual agreement signed by the Director.

    Important Notes

    COPYRIGHT 3rdDimension Developments Pty. Ltd

    ► If there are any outstanding accounts in relation to this documentationthen any copyright usage will be voided.

    FIRST FLOOR PLAN Scale 1:100

    A44 9

    CA

    B

    ELEVATIONS

    D

    NOTES:

    * ALL WATER CLOSETS TO HAVE REMOVABLEHINGES TO THE DOORS IF THERE IS LESSTHAN 1.2m CLEARANCE BETWEEN THECLOSET PAN AND THE DOORWAY.

    * ALL GLAZING TO BE INACCORDANCE WITH AS1288* SMOKE DETECTORS TO COMPLYWITH AS 3786 AND CONNECTED TOMAINS AND INTERCONNECTED.

    * CEILING FAN TO BE SWITCHEDON WITH LIGHT AS PER AUSTSTANDARDS

  • Rescode Setback

    IMPORTANT NOTE:Minimum 50mm step downbetween FFL to balcony

    NOTE: All first floor windows to havemaximum opening of 125mm

    Feature concrete

    moulds to owner's

    selection

    CL

    FL

    Gar

    age

    Colorbond slim-line sectional

    garage door with remote control

    FL

    CL

    FL

    CL

    Gro

    und

    Floo

    rFi

    rst F

    loor

    Selected colorbond custom orb

    @ 22.5 deg. pitch

    fo

    offset

    fo

    o f

    Bou

    ndar

    y

    RL 1.800

    Bou

    ndar

    y

    RL 4.840

    Ove

    rall

    wal

    l hei

    ght

    FSL

    Ove

    rall

    wal

    l hei

    ght

    Ove

    rall

    build

    ing

    heig

    ht

    RL 9.70

    Rendered

    Brickwork

    finish #1

    Lintel height

    Max

    . por

    ch h

    eigh

    t

    o f o f

    fo fo

    Selected entry door

    with 100mm moulding

    fo

    Aluminium casement

    style framed windows

    Rendered

    Brickwork

    finish #2

    NOTE: Manufacturer specificationsfor lightweight cladding systemdetails to be provided by builder.

    Rendered lightweight

    cladding

    1m(h) metal balustrade

    to NCCA requirements

    Aluminium doors

    to balcony

    R

    L

    1

    .

    3

    3

    0

    R

    L

    0

    .

    9

    8

    0

    R

    L

    1

    .

    5

    9

    0

    RL 1.714

    R

    L

    1

    .

    7

    0

    0

    L

    o

    w

    e

    s

    t

    p

    o

    i

    n

    t

    b

    e

    l

    o

    w

    r

    o

    o

    f

    a

    p

    e

    x

    Natural gro

    und line

    Offset

    Bal

    ustra

    de

    NOTE: Manufacturer specificationsfor lightweight cladding systemdetails to be provided by builder.

    oo f

    Selected colorbond

    custom orb

    @ 22.5 deg. pitch

    CL

    FL

    Gar

    age

    FL

    CL

    FL

    CL

    Gro

    und

    Floo

    rFi

    rst F

    loor

    NOTE: All first floor windows to havemaximum opening of 125mm

    Max

    . por

    ch h

    eigh

    t

    Rendered

    Brickwork

    finish #1

    Aluminium framed

    windows

    Rendered ACC

    Cladding

    finish #1

    Rendered Brickwork

    finish #2

    Rendered lightweight

    cladding

    f

    o

    Bou

    ndar

    y

    R

    L

    1

    .

    5

    9

    0

    R

    L

    1

    .

    0

    4

    0

    R

    L

    1

    .

    7

    5

    0

    R

    L

    1

    .

    4

    5

    0

    Bou

    ndar

    y

    RL 1.800

    RL 4.840

    Ove

    rall

    wal

    l hei

    ght

    Natural ground line

    Ove

    rall

    wal

    l hei

    ght

    Garage Setback

    Ma

    x. a

    ve

    ra

    ge

    w

    all

    he

    ig

    ht o

    n b

    ou

    nd

    ary

    20WIN05.02.18As shownJC

    D

    Proposed 2 Storey Dwelling

    Paul Pavli and Laura Munoz

    No. 20 Win-Malee Street, HadfieldRev. Date Description

    DATE :SCALE :DRAWN :CHECKED :

    SHEET:

    OF

    CLIENT :

    ADDRESS :

    DRAWING TITLE :

    Rev.

    A M E N D M E N T S

    REG No. :J.Campbell

    A 05.02.18 Issued as preliminary design sketchesDPAD29975B 12.02.18 Re-Issued as preliminary design sketches/Elevations

    C 19.02.18 Revised to suit clients feedback for final approvalD 02.03.18 Issued for council approval/construction plans

    ► The attached design is copyright to 3rdDimension DevelopmentsPty. Ltd. and can only be used in ANY FORM with a written/orcontractual agreement signed by the Director.

    Important Notes

    COPYRIGHT 3rdDimension Developments Pty. Ltd

    ► If there are any outstanding accounts in relation to this documentationthen any copyright usage will be voided.

    SOUTH ELEVATION-(A) Scale 1:100

    A55 9

    EAST ELEVATION-(B) Scale 1:100

    HOUSEENERGY RATING

    6 STARRATING

    AutoCAD SHX Text%%U6 STAR ENERGY REQUIREMENTS:

    AutoCAD SHX TextREQUIREMENTS AS PER 6 STAR ENERGY RATING REPORT.

    AutoCAD SHX Text-100% SEALED SINGLE GLAZED WINDOWS - STANDARD INCLUSION

    AutoCAD SHX Text-SISILATION TO ALL EXTERNAL WALLS - STANDARD INCLUSION

    AutoCAD SHX Text-REFER FLOOR PLAN & ELEVATIONS FOR DOUBLE GLAZED

    AutoCAD SHX Text-WEATHER SEALS TO ALL EXTERNAL HOUSE DOORS:

    AutoCAD SHX TextWINDOW FRAMES:

    AutoCAD SHX Text-SEAL GAPS & CRACKS AROUND ALL EXTERNAL DOOR &

    AutoCAD SHX Text-INSULATION TO EXTERNAL WALLS:

    AutoCAD SHX Text-INSULATION TO CEILING:

    AutoCAD SHX TextWINDOWS IF REQUIRED (DG):

    AutoCAD SHX Text-WEATHER STRIP(S) TO FRONT ENTRY DOOR(S):

    AutoCAD SHX Text-GARAGE INTERNAL INSULATED SAME AS EXTERNAL AS POSSIBLE

    AutoCAD SHX TextYES

    AutoCAD SHX TextYES

    AutoCAD SHX TextDouble glazing throughout

    AutoCAD SHX TextR 2.0 + FOIL

    AutoCAD SHX TextR 5.0 Celiing

    AutoCAD SHX TextYES

  • ff

    CL

    FL

    Gar

    age

    FL

    CL

    FL

    CL

    Gro

    und

    Floo

    rFi

    rst F

    loor

    offset

    Bou

    ndar

    y

    Bou

    ndar

    y

    Ove

    rall

    wal

    l hei

    ght

    Ove

    rall

    wal

    l hei

    ght

    Ove

    rall

    build

    ing

    heig

    ht

    Resc

    ode S

    etbac

    k

    f

    Aluminium framed

    windows

    Aluminium

    french doors

    f

    o

    f

    o

    oo f o f o

    Selected colorbond custom orb

    @ 22.5 deg. pitch

    Rendered lightweight

    cladding

    Feature concrete

    moulds to owner's

    selection

    R

    L

    1

    .

    6

    5

    0

    R

    L

    1

    .

    7

    5

    0

    R

    L

    1

    .

    1

    7

    0

    R

    L

    1

    .

    0

    5

    0

    Concrete

    paving

    Natu

    ral g

    round lin

    e

    RL 1.800

    RL 4.840

    Offset

    GF

    Offset

    Balcony

    Selected colorbond custom

    orb @ 22.5 deg. pitch

    FL

    CL

    FL

    CL

    Gro

    und

    Floo

    rFi

    rst F

    loor

    NOTE: All first floor windows to havemaximum opening of 125mm

    f

    o

    f

    o

    f

    o o Porch

    NOTE: Manufacturer specificationsfor lightweight cladding systemdetails to be provided by builder.

    Rendered ACC

    Cladding

    finish #1

    Aluminium framed

    windows

    Rendered lightweight

    cladding

    Feature concrete

    moulds to owner's

    selection

    R

    L

    1

    .

    4

    5

    0

    Bou

    ndar

    y

    Bou

    ndar

    y

    R

    L

    1

    .

    0

    5

    0

    R

    L

    0

    .

    9

    2

    0

    Bou

    ndar

    y

    R

    L

    1

    .

    1

    7

    0

    Natu

    ral g

    round lin

    e

    RL 1.800

    RL 4.840

    Ove

    rall

    wal

    l hei

    ght

    Ove

    rall

    wal

    l hei

    ght

    R

    L

    1

    .

    3

    3

    0

    Max

    . por

    ch h

    eigh

    t

    Dwelling Setback

    20WIN05.02.18As shownJC

    D

    Proposed 2 Storey Dwelling

    Paul Pavli and Laura Munoz

    No. 20 Win-Malee Street, HadfieldRev. Date Description

    DATE :SCALE :DRAWN :CHECKED :

    SHEET:

    OF

    CLIENT :

    ADDRESS :

    DRAWING TITLE :

    Rev.

    A M E N D M E N T S

    REG No. :J.Campbell

    A 05.02.18 Issued as preliminary design sketchesDPAD29975B 12.02.18 Re-Issued as preliminary design sketches/Elevations

    C 19.02.18 Revised to suit clients feedback for final approvalD 02.03.18 Issued for council approval/construction plans

    ► The attached design is copyright to 3rdDimension DevelopmentsPty. Ltd. and can only be used in ANY FORM with a written/orcontractual agreement signed by the Director.

    Important Notes

    COPYRIGHT 3rdDimension Developments Pty. Ltd

    ► If there are any outstanding accounts in relation to this documentationthen any copyright usage will be voided. A66 9

    NORTH ELEVATION - (C) Scale 1:100

    HOUSEENERGY RATING

    6 STARRATING

    WEST ELEVATION - (D) Scale 1:100

    AutoCAD SHX Text%%U6 STAR ENERGY REQUIREMENTS:

    AutoCAD SHX TextREQUIREMENTS AS PER 6 STAR ENERGY RATING REPORT.

    AutoCAD SHX Text-100% SEALED SINGLE GLAZED WINDOWS - STANDARD INCLUSION

    AutoCAD SHX Text-SISILATION TO ALL EXTERNAL WALLS - STANDARD INCLUSION

    AutoCAD SHX Text-REFER FLOOR PLAN & ELEVATIONS FOR DOUBLE GLAZED

    AutoCAD SHX Text-WEATHER SEALS TO ALL EXTERNAL HOUSE DOORS:

    AutoCAD SHX TextWINDOW FRAMES:

    AutoCAD SHX Text-SEAL GAPS & CRACKS AROUND ALL EXTERNAL DOOR &

    AutoCAD SHX Text-INSULATION TO EXTERNAL WALLS:

    AutoCAD SHX Text-INSULATION TO CEILING:

    AutoCAD SHX TextWINDOWS IF REQUIRED (DG):

    AutoCAD SHX Text-WEATHER STRIP(S) TO FRONT ENTRY DOOR(S):

    AutoCAD SHX Text-GARAGE INTERNAL INSULATED SAME AS EXTERNAL AS POSSIBLE

    AutoCAD SHX TextYES

    AutoCAD SHX TextYES

    AutoCAD SHX TextT.B.C.

    AutoCAD SHX TextR 2.0 + FOIL

    AutoCAD SHX TextR 5.0 Celiing

    AutoCAD SHX TextYES

  • Stair Void

    Note:Pre-fabricated roof and FloorTrussed/struts to manufacturersspecifications and details

    NOTE: All first floor windows to havemaximum opening of 125mm

    FSL

    Colorbond gutter

    & fascia (Typ.)

    Concrete Waffle slab

    to Engineer's design &

    specification

    StairsGarage

    CL

    FL

    Gar

    age

    FL

    CL

    FL

    CL

    Gro

    und

    Floo

    rFi

    rst F

    loor

    Selected colorbond

    custom orb

    @ 22.5 deg. pitch

    Bou

    ndar

    y

    RL 1.800

    Bou

    ndar

    y

    RL 4.840

    FSL

    Ove

    rall

    wal

    l hei

    ght

    Ove

    rall

    build

    ing

    heig

    ht

    RL 9.70

    offset

    R

    L

    1

    .

    3

    3

    0

    R

    L

    0

    .

    9

    8

    0

    R

    L

    1

    .

    5

    9

    0

    RL 1.714

    Rumpus

    Beam to engineersdesign andspecifications

    Refer toDETAIL-A

    Bed 3Bed 1

    Opening

    Robe

    Non-combustible MineralFibre Insulation under roofsheet

    Steel Gutter& Fascia

    RAFTERS

    240 Thick BrickVeneer Wall

    Title

    Bou

    ndar

    y

    -A BOUNDARY GUTTER DETAIL

    Zincalumeflashing

    20WIN05.02.18As shownJC

    D

    Proposed 2 Storey Dwelling

    Paul Pavli and Laura Munoz

    No. 20 Win-Malee Street, HadfieldRev. Date Description

    DATE :SCALE :DRAWN :CHECKED :

    SHEET:

    OF

    CLIENT :

    ADDRESS :

    DRAWING TITLE :

    Rev.

    A M E N D M E N T S

    REG No. :J.Campbell

    A 05.02.18 Issued as preliminary design sketchesDPAD29975B 12.02.18 Re-Issued as preliminary design sketches/Elevations

    C 19.02.18 Revised to suit clients feedback for final approvalD 02.03.18 Issued for council approval/construction plans

    ► The attached design is copyright to 3rdDimension DevelopmentsPty. Ltd. and can only be used in ANY FORM with a written/orcontractual agreement signed by the Director.

    Important Notes

    COPYRIGHT 3rdDimension Developments Pty. Ltd

    ► If there are any outstanding accounts in relation to this documentationthen any copyright usage will be voided.

    7 9

    SECTION X-X Scale 1:100

    A7

    STAIR DETAIL (TYPICAL)SCALE 1:20

    65mm Tread Housed15mm into stringer

    240x35 VIC ASH KDHWStringer.(Exposed)or equivalent

    For balustradeinformation. Refer tostair manufacturersdetails. max. openingof 125mm to NCCArequirements

    Timber handrail

    FRAMING SCHEDULEDouble StoreyGround Floors Studs - 90x45 MGP10 @ 450 Centreson Load Bearing walls ONLY90x45 MGP10 @ 450 Centres(Non-Load Bearing walls)Plates - 90x45 MGP10 Bottom Plates (On Slab)90x45 MGP10 Top PlatesFirst Floor Studs -90x45 MGP10 @ 450 Centres External Walls90x45 MGP10 @ 600 Centres Internal WallsPlates - 90x45 MGP10 Top Plates90x45 MGP10 Bottom PlatesWhen Rendered Foam (EPS)on first floor walls is used,90x45 MGP10 studs @ 450 Centres90x45 MGP10 Lintel Studs

    NOTE:STAIR COATING TO ACHIEVEP3/R10 SLIP RESISTANCE

    OPENTREADS

    Max

    .

    HOUSEENERGY RATING

    6 STARRATING

    AutoCAD SHX TextSCALE:

    AutoCAD SHX Text1:10

    AutoCAD SHX Text%%U6 STAR ENERGY REQUIREMENTS:

    AutoCAD SHX TextREQUIREMENTS AS PER 6 STAR ENERGY RATING REPORT.

    AutoCAD SHX Text-100% SEALED SINGLE GLAZED WINDOWS - STANDARD INCLUSION

    AutoCAD SHX Text-SISILATION TO ALL EXTERNAL WALLS - STANDARD INCLUSION

    AutoCAD SHX Text-REFER FLOOR PLAN & ELEVATIONS FOR DOUBLE GLAZED

    AutoCAD SHX Text-WEATHER SEALS TO ALL EXTERNAL HOUSE DOORS:

    AutoCAD SHX TextWINDOW FRAMES:

    AutoCAD SHX Text-SEAL GAPS & CRACKS AROUND ALL EXTERNAL DOOR &

    AutoCAD SHX Text-INSULATION TO EXTERNAL WALLS:

    AutoCAD SHX Text-INSULATION TO CEILING:

    AutoCAD SHX TextWINDOWS IF REQUIRED (DG):

    AutoCAD SHX Text-WEATHER STRIP(S) TO FRONT ENTRY DOOR(S):

    AutoCAD SHX Text-GARAGE INTERNAL INSULATED SAME AS EXTERNAL AS POSSIBLE

    AutoCAD SHX TextYES

    AutoCAD SHX TextYES

    AutoCAD SHX TextYES - THROUGHOUT

    AutoCAD SHX TextR 2.5 + FOIL

    AutoCAD SHX TextR 6.0 Celing

    AutoCAD SHX TextYES

  • MB

    RWH& DP

    REF. MW

    GPOforGARAGEDOOR

    AKP AlarmKeypad

    TANK

    T.V.D

    INT

    DT.V.

    PENDANT

    PARA-FLOOD

    DW

    Gas

    PARA-FLOOD

    F/place

    PENDANT

    Hotplate(In cupb'd)

    Rangehood1700(h) AFL

    2-way

    2-w

    ay

    PENDANT

    2-way

    2-w

    ay

    PARA-FLOOD

    (SENSOR)

    2-w

    ayStai

    r

    HWSGPOHWS

    GPO

    T.

    T.V.

    - POSITIONS INDICATIVE ONLY

    EQUIPMENT

    SERVICES

    ELECTRICAL LEGEND

    MH

    (RELATING TO FLOORS ON THIS SHEET ONLY)

    OYSTER LIGHT FITTING

    WALL MOUNTED BATTENHOLDER EXTERNAL

    CFL / L.E.D. DOWNLIGHT

    BATTEN HOLDER EXTERNAL

    SINGLE G.P.O. 300 HIGH

    DOUBLE G.P.O. 300 HIGH

    SINGLE G.P.O 1100 HIGH

    DOUBLE G.P.O 1100 HIGH

    PENDENT LIGHT FITTING

    SINGLE G.P.O IN CEILING

    EXHAUST FAN

    SMOKE ALARM

    DOUBLE EXTERNAL G.P.O.

    T.V. - ANTENNA SOCKET

    EXTERNAL WATER TAPTap

    MB

    GAS

    HWS

    METER BOX

    GAS METER

    HOT WATER SYSTEM1200 SINGLE FLUORESCENT WITHOPAL DIFFUSER (20WATTS)1200 DOUBLE FLUORESCENT WITHOPAL DIFFUSER (40WATTS)

    TELEPHONE POINT / DATA POINT

    IXL HEATER/FAN/LIGHTS

    DUCTED HEATING POINT (CEILING)(APPROX. POSITION)

    THERMOSTAT

    600 x 600 MAN HOLE (APPROX.POSITION)

    SOLAR HOT WATER SERVICE GAS ELECTRIC

    FIRE PLACE

    CENTRAL HEATING

    COOKTOP

    WALL OVEN

    UBO (under bench oven)

    GAS ELECTRIC

    GAS ELECTRIC

    GAS ELECTRIC

    GAS ELECTRIC

    GAS ELECTRIC

    DISHWASHER POINT

    EXHAUST FANS

    RANGE HOOD

    SPA BATH

    VACUUM SYSTEM

    YES NO

    YES NO

    YES NO

    YES NO

    YES NO

    YES NO

    ALARM SYSTEM

    WALL MOUNTED LIGHT FITTING (HEIGHT AS SHOWN)

    EXHAUST FAN & LIGHT

    D

    DUCTED HEATING POINT (UNDERFLOOR)(APPROX. POSITION)

    20WIN05.02.18As shownJC

    D

    Proposed 2 Storey Dwelling

    Paul Pavli and Laura Munoz

    No. 20 Win-Malee Street, HadfieldRev. Date Description

    DATE :SCALE :DRAWN :CHECKED :

    SHEET:

    OF

    CLIENT :

    ADDRESS :

    DRAWING TITLE :

    Rev.

    A M E N D M E N T S

    REG No. :J.Campbell

    A 05.02.18 Issued as preliminary design sketchesDPAD29975B 12.02.18 Re-Issued as preliminary design sketches/Elevations

    C 19.02.18 Revised to suit clients feedback for final approvalD 02.03.18 Issued for council approval/construction plans

    ► The attached design is copyright to 3rdDimension DevelopmentsPty. Ltd. and can only be used in ANY FORM with a written/orcontractual agreement signed by the Director.

    Important Notes

    COPYRIGHT 3rdDimension Developments Pty. Ltd

    ► If there are any outstanding accounts in relation to this documentationthen any copyright usage will be voided.

    GROUND FLOORScale 1:100

    A88 9

    ELECTRICAL PLAN

    DWELLING: (5 Watts/M TOTAL AREA

    TOTALALLOWANCE COMPLIANCE

    PORCH/ALFRESCO/BALCONY: (4 Watts/MMAXIMUM)

    GARAGE: (3 Watts/M

    OTHER:

    CEILING AREAUNINSULATED

    PERCENTAGE OF CEILING AREAUNINSULATED

    ADJUSTMENT FOR MINIMUM R-VALUE FOR LOSS OF CEILING INSULATION

    R 5.0 R 5.0

    ELECTRICAL COMPLIANCE LEGEND

    120 WATT EXTERNAL LIGHT CONTROLLED BY DAYLIGHT SENSOR OR AVERAGE LIGHT SOURCE EFFICIENCYOF NOT LESS THAN 40 LUMENS/W

    9 WATT COMPACT FLUORESCENT/LED RECESSED LIGHT

    WATTSNO.

    9 WATT L.E.D RECESSED DOWNLIGHT

    NO.

    9 WATT L.E.D DOWNLIGHT (0.0197m )

    SELF-SEALING EXHAUST FANS (0.071m )

    RANGEHOOD (VENTED THROUGH CEILING) (0.008m )TOTALWATTS

    %

    426 W 252 M39

    18 W M2 5

    80 W M36

    0.851 M

    39

    M 0.33252

    2

    0

    W1388.00524 W

    15 WATT WARM COMPACT FLUORESCENT GLOBE LIGHT 5

    20 WATT FLUORESCENT TUBE 4

    15 WATT WARM COMPACT FLUORESCENT GLOBE LIGHT 0

    * SMOKE DETECTORS TO COMPLYWITH AS 3786 AND CONNECTED TOMAINS AND INTERCONNECTED.

    * CEILING FAN TO BE SWITCHEDON WITH LIGHT AS PER AUSTSTANDARDS

    AutoCAD SHX TextTH.

    AutoCAD SHX TextTH.

    AutoCAD SHX Text² MAXIMUM) MAXIMUM)

    AutoCAD SHX Text²

    AutoCAD SHX Text² MAXIMUM) MAXIMUM)

    AutoCAD SHX TextLIGHTING USED IN DWELLING

    AutoCAD SHX TextCEILING AREA

    AutoCAD SHX TextR-VALUE OF CEILING INSULATION REQUIRED TO ACHIEVE 6* ENERGY RATING

    AutoCAD SHX TextADJUSTED R-VALUE OF CEILING INSULATION TO COMPLY WITH B.C.A. 3.12.1.1

    AutoCAD SHX Text²)

    AutoCAD SHX Text²)

    AutoCAD SHX Text²)

    AutoCAD SHX Text²

    AutoCAD SHX Text²

    AutoCAD SHX Text²

    AutoCAD SHX Text²

    AutoCAD SHX Text²

  • ACPAlarmcontrolpanel

    TWALL-MOUNT

    T.V.

    1500mm(H)Above FL

    PENDANT

    2-way

    2-way

    T.

    T.V.

    - POSITIONS INDICATIVE ONLY

    EQUIPMENT

    SERVICES

    ELECTRICAL LEGEND

    MH

    (RELATING TO FLOORS ON THIS SHEET ONLY)

    OYSTER LIGHT FITTING

    WALL MOUNTED BATTENHOLDER EXTERNAL

    CFL / L.E.D. DOWNLIGHT

    BATTEN HOLDER EXTERNAL

    SINGLE G.P.O. 300 HIGH

    DOUBLE G.P.O. 300 HIGH

    SINGLE G.P.O 1100 HIGH

    DOUBLE G.P.O 1100 HIGH

    PENDENT LIGHT FITTING

    SINGLE G.P.O IN CEILING

    EXHAUST FAN

    SMOKE ALARM

    DOUBLE EXTERNAL G.P.O.

    T.V. - ANTENNA SOCKET

    EXTERNAL WATER TAPTap

    MB

    GAS

    HWS

    METER BOX

    GAS METER

    HOT WATER SYSTEM1200 SINGLE FLUORESCENT WITHOPAL DIFFUSER (20WATTS)1200 DOUBLE FLUORESCENT WITHOPAL DIFFUSER (40WATTS)

    TELEPHONE POINT / DATA POINT

    IXL HEATER/FAN/LIGHTS

    DUCTED HEATING POINT (CEILING)(APPROX. POSITION)

    THERMOSTAT

    600 x 600 MAN HOLE (APPROX.POSITION)

    SOLAR HOT WATER SERVICE GAS ELECTRIC

    FIRE PLACE

    CENTRAL HEATING

    COOKTOP

    WALL OVEN

    UBO (under bench oven)

    GAS ELECTRIC

    GAS ELECTRIC

    GAS ELECTRIC

    GAS ELECTRIC

    GAS ELECTRIC

    DISHWASHER POINT

    EXHAUST FANS

    RANGE HOOD

    SPA BATH

    VACUUM SYSTEM

    YES NO

    YES NO

    YES NO

    YES NO

    YES NO

    YES NO

    ALARM SYSTEM

    WALL MOUNTED LIGHT FITTING (HEIGHT AS SHOWN)

    EXHAUST FAN & LIGHT

    D

    DUCTED HEATING POINT (UNDERFLOOR)(APPROX. POSITION)

    20WIN05.02.18As shownJC

    D

    Proposed 2 Storey Dwelling

    Paul Pavli and Laura Munoz

    No. 20 Win-Malee Street, HadfieldRev. Date Description

    DATE :SCALE :DRAWN :CHECKED :

    SHEET:

    OF

    CLIENT :

    ADDRESS :

    DRAWING TITLE :

    Rev.

    A M E N D M E N T S

    REG No. :J.Campbell

    A 05.02.18 Issued as preliminary design sketchesDPAD29975B 12.02.18 Re-Issued as preliminary design sketches/Elevations

    C 19.02.18 Revised to suit clients feedback for final approvalD 02.03.18 Issued for council approval/construction plans

    ► The attached design is copyright to 3rdDimension DevelopmentsPty. Ltd. and can only be used in ANY FORM with a written/orcontractual agreement signed by the Director.

    Important Notes

    COPYRIGHT 3rdDimension Developments Pty. Ltd

    ► If there are any outstanding accounts in relation to this documentationthen any copyright usage will be voided.

    Scale 1:100

    A99 9

    DWELLING: (5 Watts/M TOTAL AREA

    TOTALALLOWANCE COMPLIANCE

    PORCH/ALFRESCO/BALCONY: (4 Watts/MMAXIMUM)

    GARAGE: (3 Watts/M

    OTHER:

    CEILING AREAUNINSULATED

    PERCENTAGE OF CEILING AREAUNINSULATED

    ADJUSTMENT FOR MINIMUM R-VALUE FOR LOSS OF CEILING INSULATION

    R 5.0 R 5.0

    ELECTRICAL COMPLIANCE LEGEND

    120 WATT EXTERNAL LIGHT CONTROLLED BY DAYLIGHT SENSOR OR AVERAGE LIGHT SOURCE EFFICIENCYOF NOT LESS THAN 40 LUMENS/W

    9 WATT COMPACT FLUORESCENT/LED RECESSED LIGHT

    WATTSNO.

    9 WATT L.E.D RECESSED DOWNLIGHT

    NO.

    9 WATT L.E.D DOWNLIGHT (0.0197m )

    SELF-SEALING EXHAUST FANS (0.071m )

    RANGEHOOD (VENTED THROUGH CEILING) (0.008m )TOTALWATTS

    %

    426 W 252 M39

    18 W M2 5

    80 W M36

    0.851 M

    39

    M 0.33252

    2

    0

    W1388.00524 W

    15 WATT WARM COMPACT FLUORESCENT GLOBE LIGHT 5

    20 WATT FLUORESCENT TUBE 4

    15 WATT WARM COMPACT FLUORESCENT GLOBE LIGHT 0

    ELECTRICAL PLAN

    * SMOKE DETECTORS TO COMPLYWITH AS 3786 AND CONNECTED TOMAINS AND INTERCONNECTED.

    * CEILING FAN TO BE SWITCHEDON WITH LIGHT AS PER AUSTSTANDARDS

    AutoCAD SHX TextTH.

    AutoCAD SHX TextTH.

    AutoCAD SHX Text² MAXIMUM) MAXIMUM)

    AutoCAD SHX Text²

    AutoCAD SHX Text² MAXIMUM) MAXIMUM)

    AutoCAD SHX TextLIGHTING USED IN DWELLING

    AutoCAD SHX TextCEILING AREA

    AutoCAD SHX TextR-VALUE OF CEILING INSULATION REQUIRED TO ACHIEVE 6* ENERGY RATING

    AutoCAD SHX TextADJUSTED R-VALUE OF CEILING INSULATION TO COMPLY WITH B.C.A. 3.12.1.1

    AutoCAD SHX Text²)

    AutoCAD SHX Text²)

    AutoCAD SHX Text²)

    AutoCAD SHX Text²

    AutoCAD SHX Text²

    AutoCAD SHX Text²

    AutoCAD SHX Text²

    AutoCAD SHX Text²

    Sheets and Views20WIN-WD-revD-A1OLE5

    20WIN-WD-revD-A2OLE5

    20WIN-WD-revD-A3OLE5

    20WIN-WD-revD-A4OLE5

    20WIN-WD-revD-A5OLE5

    20WIN-WD-revD-A6OLE5

    20WIN-WD-revD-A7OLE5

    20WIN-WD-revD-A8OLE5

    20WIN-WD-revD-A9OLE5