3
Gendrive Series 2000 Gx6 for Power Generation Standard Backup Applications with water-to-air charge air cooling Power. Passion. Partnership. Dimensions and Masses Engine Dimensions (LxWxH) mm (in) Mass, dry kg (lbs) 12V 1885 x 1546 x 1420 (74 x 61 x 56) 2710 (5975) 16V 2235 x 1568 x 1420 (88 x 62 x 56) 3180 (7011) All dimensions are approximate, for complete information refer to the installation drawing. Engine Model Bore/stroke mm (in) 135/156 (5.3/6.15) Cylinder configuration 90°V Displacement/cylinder l (cu in) 2.23 (136) Displacement, total l (cu in) 12V: 26.76 (1633), 16V: 35.68 (2177) Fuel specification EN 590, Grade No.1-D/2-D (ASTM D975-00) Application group Power definition Standby Power (3D) Emergency service, fuel stop power, Load factor: ≤ 85%, Operating hours: max. 500/year, IFN Overload: Fuel stop power (IFN) Power definition according to ISO 3046 (ratings also correspond to SAE J 1995 and SAE J 1349 standard conditions). Consult your MTU distributor/dealer for the rating that will apply to your specific application. Rated power is without fan drive. The power consumption of any fan drive has to be deducted during designing of a generator set.

Gendrive Series 2000 Gx6 - Arbasarbas.co.id/wp-content/uploads/2016/12/32310311_MTU_Gen...Gendrive Series 2000 Gx6 for Power Generation Standard Backup Applications with water-to-air

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Gendrive Series 2000 Gx6 - Arbasarbas.co.id/wp-content/uploads/2016/12/32310311_MTU_Gen...Gendrive Series 2000 Gx6 for Power Generation Standard Backup Applications with water-to-air

Gendrive

Series 2000 Gx6 for Power Generation Standard Backup Applicationswith water-to-air charge air cooling

Power. Passion. Partnership.

Dimensions and Masses

Engine Dimensions(LxWxH)mm(in) Mass,drykg(lbs)

12V 1885x1546x1420(74x61x56) 2710(5975)

16V 2235x1568x1420(88x62x56) 3180(7011)

Alldimensionsareapproximate,forcompleteinformationrefertotheinstallationdrawing.

EngineModel

Bore/stroke mm(in) 135/156(5.3/6.15)

Cylinderconfiguration 90°V

Displacement/cylinder l(cuin) 2.23(136)

Displacement,total l(cuin) 12V:26.76(1633),16V:35.68(2177)

Fuelspecification EN590,GradeNo.1-D/2-D(ASTMD975-00)

Applicationgroup Powerdefinition

StandbyPower(3D) Emergencyservice,fuelstoppower, Loadfactor:≤85%,Operatinghours:max.500/year,

IFN Overload:Fuelstoppower(IFN)

PowerdefinitionaccordingtoISO3046(ratingsalsocorrespondtoSAEJ1995andSAEJ1349standardconditions).ConsultyourMTUdistributor/dealerfortheratingthatwillapplytoyourspecificapplication.Rated power is without fan drive. The power consumption of any fan drive has to be deducted during designing of a generator set.

Page 2: Gendrive Series 2000 Gx6 - Arbasarbas.co.id/wp-content/uploads/2016/12/32310311_MTU_Gen...Gendrive Series 2000 Gx6 for Power Generation Standard Backup Applications with water-to-air

2IStandardBackupApplications

Standby Power (3D)

Engine Type Rated power kW (bhp) at 1500 rpm (50Hz) Optimization

12V2000G76S 890(1194) x x x

12V2000G86S 987(1324) x x x

16V2000G76S 1097(1471) x x x

16V2000G86S 1371(1839) x x x

Fanpowerrequirementnotconsidered

Fuel

con

sum

ptio

n op

timiz

ed

Engine Type Rated power kW (bhp) at 1800 rpm (60Hz) Optimization

US

EPA

Sta

tiona

ry

EMER

G T

ier

2 (4

0 C

FR 6

0)

US

EPA

Non

road

Tie

r 2

com

plia

nt (4

0 C

FR 8

9)

193

3 19 referencetoemissionlevelinpricelist

Page 3: Gendrive Series 2000 Gx6 - Arbasarbas.co.id/wp-content/uploads/2016/12/32310311_MTU_Gen...Gendrive Series 2000 Gx6 for Power Generation Standard Backup Applications with water-to-air

MTU Friedrichshafen GmbH I MTU Asia Pte Ltd I MTU America Inc.Rolls-RoycePowerSystemsCompanies

www.mtu-online.com

StandardEquipment

StartingSystem 1electricstarter(24VDC/2-pole)

FuelSystem Electronicallycontrolledcommon-railhigh-pressureinjectionsystem,dualenginemountedfuelfilters

LubeOilSystem Forcedfeedlubricationsystemwithpistoncooling,lubeoilcirculationpump,lubeoilfilter,lubeoilheatexchanger

CombustionAirSystem 2exhaustturbochargers,water-to-airintercoolerintegratedinradiator

CoolingSystem Coolantcirculationpumpandcoolantthermostatforjacketwatercircuit

EngineMounting Setofenginemountingbracketsforresilientmount

EngineManagement IntegratedelectronicenginecontrolandmonitoringsystemADEC,customerinterface„SmartConnect“

OptionalEquipment

StartingSystem Compressedair,redundantstartingsystem:electric/electric;air/air;electric/air

FuelSystem Fuelpre-filter,specialfuelpre-filterwithwaterseparator

CombustionAirSystem Heavydutyairfilters

CoolingSystem Enginemountedfandrive

EngineMounting Resilientenginemounts(rubberelements),rigidenginemounting

AuxiliaryPowerSupply Batterychargingalternator

Referenceconditions:–Intake-airtemperature:25°C(77°F)–Ambientairpressure:1bar(14.5psi)–Altitudeabovesealevel:100m(328ft)

Subjecttochangewithoutnotice.Customizationpossible.Enginesillustratedinthisdocumentmayfeatureoptionsnotfittedasstandard.

Subj

ectt

och

ange

.|3

2310

311

|Ed

ition

01/

16|

EN

C2

016-

03.