30

Gen Set Catalogue

Embed Size (px)

Citation preview

Powered by

Automatic Gen-Set Controllerswith Remote Control & Visualisation ................................. 3

Enhanced Automatic Gen-Set Controllerswith Transfer Switching ....................................................... 7

Automatic Gen-Set Controllerswith Transfer Switching .................................................... 15

Auto Start Gen-Set Protection & Controllers .................. 18

Manual Key Start & Engine Protectionwith Key Switch ................................................................. 24

Automatic Transfer Switch ................................................ 25

Battery Charger .................................................................. 27

About EMKO ..................................................................... 28

Automatic Gen-Set Controllerswith Transfer Switching

2

Comparison Table

Model EAOM-19 EAOM-9 EAOM-9F EAOM-210.FD EAOM-210.FL Messenger Messenger.ProEAOM-210.FDJ** EAOM-210.FLJ**

Dimensions (mm) 72x72 96x96 144x204 144x204 144x204 144x204 144x204

Display LED LED LED LED LCD (Graphic) LCD (Graphic) LCD (Graphic)

Generator L1/N L1/N L1/N L1/L2, L1/N L1/L2, L1/N L1/L2, L1/N L1/L2, L1/NVoltage L2/L3, L2/N L2/L3, L2/N L2/L3, L2/N L2/L3, L2/NMeasurement L3/L1, L3/N L3/L1, L3/N L3/L1, L3/N L3/L1, L3/N

Mains Voltage L1/L2, L1/N L1/L2, L1/N L1/L2, L1/N L1/L2, L1/N L1/L2, L1/N L1/L2, L1/N L1/L2, L1/NMeasurement L2/L3, L2/N L2/L3, L2/N L2/L3, L2/N L2/L3, L2/N L2/L3, L2/N L2/L3, L2/N L2/L3, L2/N

L3/L1, L3/N L3/L1, L3/N L3/L1, L3/N L3/L1, L3/N L3/L1, L3/N L3/L1, L3/N L3/L1, L3/N

Generator No No No KVAh, kWh, kVA, KVAh, kWh, kVA, KVAh, kWh, kVA, KVAh, kWh, kVA,Power kW, kVAr, kVarh kW, kVAr, kVarh kW, kVAr, kVarh kW, kVAr, kVarhMeasurement

Load Current No No No Yes Yes Yes YesMeasurement

Earth Current No No No Yes Yes Yes YesMeasurement

Outputs Start, Fuel, Horn, Start, Fuel, Horn, Start, Fuel, Horn, Start, Fuel, Horn, Start, Fuel, Horn, Start, Fuel, Horn, Start, Fuel, Horn,Mains and Mains and Mains and Mains Open and Mains Open and Mains Open and Mains Open andGenerator Generator Generator Close, Generator Close, Generator Close, Generator Close, GeneratorContactor Contactor Contactor Open and Close Open and Close Open and Close Open and Close

Configurable No 1 User 1 User 4 User 4 User, 4 User, 4 User,Outputs Configurable Configurable Configurable Configurable Configurable Configurable

+8 conf.w/expansion

board

Configurable 2 User 2 User 2 User 6 User 6 User, 6 User, 6 User,Inputs Configurable Configurable Configurable Configurable Configurable Configurable Configurable

+8 conf.w/expansion

board

Outputs Type Relay Relay Transistor Relay Relay Relay Relay

Analogue No No No Oil Pressure Oil Pressure Oil Pressure Oil PressureResistive Fuel Level Fuel Level Fuel Level Fuel LevelSender Inputs Temperature Temperature Temperature Temperature

Speed Sensing From From From From From From FromAlternator Alternator Alternator Alternator Alternator Alternator Alternator

signal signal signal signal signal signal signalor magnetic or magnetic or magnetic or magnetic or magnetic or magnetic

pickup pickup pickup pickup pickup pickup

Two Level Operator & Operator & Operator & Operator & Operator & Operator & Operator &Passwords Technician Technician Technician Technician Technician Technician Technician

Timer Timer Timer Timer Real Time Timer Real Time Timer Real Time Timer Real Time Timer

Engine No Yes Yes Yes Yes Yes YesRunning Time

Programmable No No No Yes Yes Yes YesWorking Timer

Event Logs No No No Last 50 events Last 32 events Last 32 events Last 32 eventson device and allevents archived

on PC

J-1939 ECU No No No **only available in **only available in Yes YesCommunication FDJ FLJ

Communication No RS-232 Serial RS-232 Serial RS-232 ModBus RS-232 ModBus RS-232 ModBus RS-232 ModBusStandard Modem RTU, ASCII, ASCII, ASCII,

Standard Modem Standard Modem GSM, SMS Standard ModemEthernet, Internet

Sends SMS to pre-defined GSM numbers for alarms

Controls the generator and monitors status information of the generator by SMS

Remote control via internet, intranet, GSM or dial-up modem

Access to multiple generators by Gen-Agent SCADA software

CanBus J1939 ECU communication

SPN, FMI and OC values reading from engine via J1939

Authorised access, secure communication

Suitable for telecommunication projects

Automatic transfer switching control and engine control

Logs last 32 events & alarm informations

Full metering facility, energy and power measurement

144x204 mm size, Flat type

Automatic Gen-Set Controllerswith Remote Control & Visualisation

3

The status of your generatoris only a text message away :)

Two-way SMS communication(GenSet to mobile)

Options Back

Sender+905305227470

Generator No3:03.07.200816:08:12Level Prealarm

Send commandby SMS

Notification of alarmstatus by SMS

Enquire statusby SMS

Receive feed-backmessage for status

Acknowledgementmessage for

command sent

Options Back

Sender+905305227470

Generator No3:Ok

Enquire for activemeasured values

Enquire forparameter values

by SMS

Feed-back messagefor parametervalues read

Change parametervalues by SMS

Feed-back messagefor active measured

values

Order information

MESSENGER Enhanced automatic Gen Set controller with transfer switching,SMS communication by build-in internal GSM modem and configuration software

#1:read s?

Options Send

Sender+905305227470

Generator No3:AUTO, Engine isnot running, Loadfrom mains

Options Back

#1:read c1

Options Send

#1:read h235

Options Send

Sender+905305227470

Generator No3:1300

Options Back

#1:read w235 1200, p1234

Options Send

#1:read r20

Options Send

Sender+905305227470

Generator No3:380

Options Back

GSMSMS

send/receive

Automatic Gen-Set Controllerswith Remote Control & Visualisation

4

Real-time technology allows for real-time feedback - Know thestatus of your generator instantly! Only a text message away...

sends alarm informations to pre-defined GSM numbers viainternal GSM modem. User may control the device, CLEAR alarms, RESET,change MODE’s, STOP, START, access the PARAMETER’s of device,change the parameters and enquire information about generator’s activestatus by sending and receiving SMS. Accessing and trouble shooting of theGen-Sets outside of residental area & all around the world is possible.

Remote control & visualisationfor multiple Gen-Sets

.PRO enables continuous communication with build in ethernet and dial-up modem facility. Gen-Agent SCADAsoftware offers remote control & visualisation and maintenance management of multiple Gen-Sets from a central computer viainternet by ADSL connected to telephone or local ethernet network. Software also observes for alarms and archieves them.The failures and alarms traced by Gen-Agent SCADA software can be sent to 3 GSM numbers pre-defined in software for yourinformation.

ADSLModem

GSMSMS

Order information

MESSENGER.PRO Enhanced automatic Gen-Set controller with transfer switching,Build-in Ethernet & Dial-up modem communication, multiple Gen-Set visualisation& control by Gen-Agent SCADA software

Gen-Agent SCADA software

Automatic Gen-Set Controllerswith Remote Control & Visualisation

5

3 phase mains and 3 phase generator voltage measurement,3 phase load current and earth current measurement,Contactor open and close relay outputs for mains and generator,Configurable 6 inputs and 4 outputs,3 resistive sender inputs for oil pressure, temperature and level,Speed sensing from alternator voltage or magnetic pickup,Stop or fuel solenoid selection,Programmable weekly working permit calendar,Maintenance warning (working hour or elapsed month),Exercise at programmed time intervals,OFF, Manual, Auto and Test mode,Power measurement by kVA, kW, kVAr, kVAh, kWh, kVArh,Compatible to Diesel or Gas generators

Automatic Gen-Set Controllers

with Remote Control & Visualisation

Enhanced automaticGen-Set controller with transfer switching

Sta

rt

Sol

enoi

d

Tem

pera

ture

Oil

Pre

ssur

e

Leve

l

Bat

tery

vol

tage

Mag

netic

Pic

kup

(RP

M)

Relayoutputs

Analogue inputs

4 configurablerelay outputs

6 configurabledigital inputs

Engine Control

Digital inputsMESSENGER.PRO

+Vba

t

-Vba

t

-Vba

t

D+(

W.L

.)C

harg

e G

en.

E.S

top

Generator Mains

Contactoropen / close

8-32Vdc

Supply voltage

Phoneline

Ethernet

Communication

RS-232 ModBus ASCII

5

GSMmodem

MESSENGER

sim cardsocket

XCel

l

6

Can

Bus

J19

39E

CU

com

mun

icat

ion

Enhanced Automatic Gen-Set Controllerswith Transfer Switching

7

EAOM-210.FL

Fail MonitoringEmergency stopMultiple engage failFailed to startLow oil pressureHigh temperatureSpeed failureVoltage failureCharging failSpare-1, 2, 3

ErrorSpare-4, 5, 6Over / Under speedSpeed lossEarth faultFuel levelBattery lowBattery highMaintenanceOver currentShort circuitEngine stop

Pre-AlarmEngine temperatureOver / Under voltageOver / Under frequencyOver / Under speedOil pressureFuel level

Warning & Electrical tripEarth faultOver currentShort circuit

AlarmMains breaker not openedMains breaker not closedGenerator breaker not openedGenerator breaker not closed

ControlsFuel and Stop solenoidStarter motorAutomatic generator startLoad transfer to mainsPreheatExternal alarm horn

Remote control via RS-232 ModBus or dial-up modem,

Authorised access, secure communication,

Automatic transfer switching control and engine control,

Logs last 32 events & alarm informations,

Full metering facility, energy and power measurement,

3 phase mains and 3 phase generator voltage measurement,

3 phase load current and earth current measurement,

Contactor open and close relay outputs for mains and generator,

Configurable 6 inputs and 4 outputs,

Optional configurable 8 inputs and 8 outputs with Expansion I/O Board,

3 resistive sender inputs for oil pressure, temperature and level,

Speed sensing from alternator voltage or magnetic pickup,

Stop or fuel solenoid selection,

Programmable weekly working permit calendar,

Maintenance warning (working hour or elapsed month),

Exercise at programmed time intervals,

OFF, Manual, Auto and Test mode,

Power measurement by kVA, kW, kVAr, kVAh, kWh, kVArh,

Compatible to Diesel or Gas generators,

144x204 mm size, Flat type

Enhanced Automatic Gen-Set Controllerswith Transfer Switching

8

EAOM-210.FL

Sta

rt

Sol

enoi

d

Tem

pera

ture

Oil

Pre

ssur

e

Leve

l

Bat

tery

vol

tage

Mag

netic

Pic

kup

(RP

M)

Relayoutputs

Analogue inputs

4 configurablerelay outputs

6 configurabledigital inputs

Engine Control

Digital inputs

+Vba

t

-Vba

t

-Vba

t

D+(

W.L

.)

Cha

rge

Gen

.

E.S

top

Generator Mains

Contactoropen / close

8-32VdcSupply voltage

CommunicationRS-232

ModBus ASCII

5

OptionalExpansion I/O Board

Communication

OptionalExpansionI/O Board

EAOM-210.FL.EXR

8 configurabledigital inputs

8 configurablerelay outputs

Sta

rt

Sol

enoi

d

Tem

pera

ture

Oil

Pre

ssur

e

Leve

l

Bat

tery

vol

tage

Relayoutputs

Analogue inputs

2 configurablerelay outputs

6 configurabledigital inputs

Engine Control

Digital inputs

+Vba

t

-Vba

t

-Vba

t

D+(

W.L

.)

Cha

rge

Gen

.

E.S

top

Generator Mains

Contactor

8-32VdcSupply voltage

CommunicationRS-232

ModBus ASCII

5

OptionalExpansion I/O Board

Communication

OptionalExpansionI/O Board

EAOM-210.FL.EXR

8 configurabledigital inputs

8 configurablerelay outputs

Contactor

2

EAOM-210.FL.S

EAOM-210.FL

Order information

EAOM-210.FL Enhanced automatic Gen-Set controller with transfer switching, LCD display

EAOM-210.FL.S Automatic Gen-Set controller with transfer switching, LCD display

EAOM-210.FL-EXR I/O Expansion Board which is DIN rail mounting type, including 2m CanBus cable

MODEM-EXR V.32bis / 14.000bps Dial-up Modem unit, DIN rail mounting type, including 2m RS-232 cable(for connection to RS-232 port of EAOM-210.FL) 8-32Vdc supply voltage

ENCV-232/485-EXR RS-232 / RS-485 Convertor unit, DIN rail mounting type, including 2m RS-232 cable(for connection to RS-232 port of EAOM-210.FL), 1000V galvanic insulation, 8-32Vdc supply voltage

EAOM-210.FL-SOFT PC Communication software for Remote control and Programming

EAOM-210.FL.S-SOFT PC Communication software for Remote control and Programming

Enhanced Automatic Gen-Set Controllerswith Transfer Switching

9

EAOM-210.FLJ

Fail MonitoringEmergency stopMultiple engage failFailed to startLow oil pressureHigh temperatureSpeed failureVoltage failureCharging failSpare-1, 2, 3

ErrorSpare-4, 5, 6Over / Under speedSpeed lossEarth faultFuel levelBattery lowBattery highMaintenanceOver currentShort circuitEngine stop

Pre-AlarmEngine temperatureOver / Under voltageOver / Under frequencyOver / Under speedOil pressureFuel level

Warning & Electrical tripEarth faultOver currentShort circuit

AlarmMains breaker not openedMains breaker not closedGenerator breaker not openedGenerator breaker not closed

ControlsFuel and Stop solenoidStarter motorAutomatic generator startLoad transfer to mainsPreheatExternal alarm horn

CanBus J1939 ECU communication

Remote control via RS-232 ModBus or dial-up modem,

Authorised access, secure communication,

Automatic transfer switching control and engine control,

Logs last 32 events & alarm informations,

Remote Start/Stop, Speed and Idle mode control via J1939 for Volvo EMS2

Power factor measurement for 3 phases

SPN, FMI and OC values reading from engine via J1939

3 phase mains and 3 phase generator voltage measurement,

3 phase load current and earth current measurement,

Contactor open and close relay outputs for mains and generator,

Configurable 6 inputs and 4 outputs,

Optional configurable 8 inputs and 8 outputs with Expansion I/O Board,

3 resistive sender inputs for oil pressure, temperature and level,

Speed sensing from alternator voltage or magnetic pickup,

Stop or fuel solenoid selection,

Programmable weekly working permit calendar,

Maintenance warning (working hour or elapsed month),

Exercise at programmed time intervals,

OFF, Manual, Auto and Test mode,

Power measurement by kVA, kW, kVAr, kVAh, kWh, kVArh,

Compatible to Diesel or Gas generators,

144x204 mm size, Flat type

CanBus J1939 ECUcommunication

Enhanced Automatic Gen-Set Controllerswith Transfer Switching

10

EAOM-210.FLJ

Sta

rt

Sol

enoi

d

Tem

pera

ture

Oil

Pre

ssur

e

Leve

l

Bat

tery

vol

tage

Mag

netic

Pic

kup

(RP

M)

Relayoutputs

Analogue inputs

4 configurablerelay outputs

6 configurabledigital inputs

Engine Control

Digital inputs

+Vba

t

-Vba

t

-Vba

t

D+(

W.L

.)

Cha

rge

Gen

.

E.S

top

Generator Mains

Contactoropen / close

8-32VdcSupply voltage

CommunicationRS-232

ModBus ASCII

5

OptionalExpansion I/O Board

Communication

OptionalExpansionI/O Board

EAOM-210.FL.EXR

8 configurabledigital inputs

8 configurablerelay outputs

Sta

rt

Sol

enoi

d

Tem

pera

ture

Oil

Pre

ssur

e

Leve

l

Bat

tery

vol

tage

Relayoutputs

Analogue inputs

2 configurablerelay outputs

6 configurabledigital inputs

Engine Control

Digital inputs

+Vba

t

-Vba

t

-Vba

t

D+(

W.L

.)

Cha

rge

Gen

.

E.S

top

Generator Mains

Contactor

8-32VdcSupply voltage

CommunicationRS-232

ModBus ASCII

5

OptionalExpansion I/O Board

Communication

OptionalExpansionI/O Board

EAOM-210.FL.EXR

8 configurabledigital inputs

8 configurablerelay outputs

Contactor

2

EAOM-210.FLJ.S

EAOM-210.FLJ

Can

Bus

J19

39E

CU

com

mun

icat

ion

Can

Bus

J19

39E

CU

com

mun

icat

ion

Order information

EAOM-210.FLJ Enhanced automatic Gen-Set controller with transfer switching, LCD display, J1939 ECU comm.

EAOM-210.FLJ.S Automatic Gen-Set controller with transfer switching, LCD display, J1939 ECU comm.

EAOM-210.FL-EXR I/O Expansion Board which is DIN rail mounting type, including 2m CanBus cable

MODEM-EXR V.32bis / 14.000bps Dial-up Modem unit, DIN rail mounting type, including 2m RS-232 cable(for connection to RS-232 port of EAOM-210.FLJ) 8-32Vdc supply voltage

ENCV-232/485-EXR RS-232 / RS-485 Convertor unit, DIN rail mounting type, including 2m RS-232 cable(for connection to RS-232 port of EAOM-210.FLJ), 1000V galvanic insulation, 8-32Vdc supply voltage

EAOM-210.FLJ-SOFT PC Communication software for Remote control and Programming

EAOM-210.FLJ.S-SOFT PC Communication software for Remote control and Programming

CanBus J1939 ECUcommunication

Fail MonitoringEmergency stopMultiple engage failFailed to startLow oil pressureHigh temperatureSpeed failureVoltage failureCharging failSpare-1, 2, 3

ErrorSpare-4, 5, 6Over / Under speedSpeed lossEarth faultFuel levelBattery lowBattery highMaintenanceOver currentShort circuitEngine stop

Pre-AlarmEngine temperatureOver / Under voltageOver / Under frequencyOver / Under speedOil pressureFuel level

Warning & Electrical tripReverse powerEarth faultOver currentShort circuit

AlarmMains breaker not openedMains breaker not closedGenerator breaker not openedGenerator breaker not closed

ControlsFuel and Stop solenoidStarter motorAutomatic generator startLoad transfer to mainsPreheatExternal alarm horn

Enhanced Automatic Gen-Set Controllerswith Transfer Switching

11

EAOM-210.FD

Remote control via RS-232 ModBus or dial-up modem,

Authorised access, secure communication,

Automatic transfer switching control and engine control,

Logs last 50 events & alarm informations,

Full metering facility, energy and power measurement,

3 phase mains and 3 phase generator voltage measurement,

3 phase load current and earth current measurement,

Contactor open and close relay outputs for mains and generator,

Configurable 6 inputs and 4 outputs,

3 resistive sender inputs for oil pressure, temperature and level,

Speed sensing from alternator voltage or magnetic pickup,

Stop or fuel solenoid selection,

Maintenance warning (working hour or elapsed month),

Exercise at programmed time intervals,

OFF, Manual, Auto and Test mode,

Power measurement by kVA, kW, kVAr, kVAh, kWh, kVArh,

Compatible to Diesel or Gas generators,

144x204 mm size, Flat type

Enhanced Automatic Gen-Set Controllerswith Transfer Switching

12

EAOM-210.FD

Sta

rt

Sol

enoi

d

Tem

pera

ture

Oil

Pre

ssur

e

Leve

l

Bat

tery

vol

tage

Mag

netic

Pic

kup

(RP

M)

Relayoutputs

Analogue inputs

4 configurablerelay outputs

6 configurabledigital inputs

Engine Control

Digital inputs

+Vba

t

-Vba

t

-Vba

t

D+(

W.L

.)

Cha

rge

Gen

.

E.S

top

Generator Mains

Contactoropen / close

8-32VdcSupply voltage

CommunicationRS-232

ModBus RTU

5S

tart

Sol

enoi

d

Tem

pera

ture

Oil

Pre

ssur

e

Leve

l

Bat

tery

vol

tage

Mag

netic

Pic

kup

(RP

M)

Relayoutputs

Analogue inputs

2 configurablerelay outputs

6 configurabledigital inputs

Engine Control

Digital inputs

+Vba

t

-Vba

t

-Vba

t

D+(

W.L

.)

Cha

rge

Gen

.

E.S

top

Generator Mains

Contactor

8-32VdcSupply voltage

CommunicationRS-232

ModBus ASCIIor RTU

5

Contactor

2

EAOM-210.FD.S

EAOM-210.FD

Order information

EAOM-210.FD Enhanced automatic Gen-Set controller with transfer switching, LED display

EAOM-210.FD.S Automatic Gen-Set controller with transfer switching, LED display

MODEM-EXR V.32bis / 14.000bps Dial-up Modem unit, DIN rail mounting type, including 2mRS-232 cable (for connection to RS-232 port of EAOM-210.FD) 8-32Vdc supply voltage

ENCV-232/485-EXR RS-232 / RS-485 Convertor unit, DIN rail mounting type, including 2m RS-232 cable(for connection to RS-232 port of EAOM-210.FD), 1000V galvanic insulation, 8-32Vdc supply voltage

EAOM-210.FD-SOFT PC Communication software for Remote control and Programming

EAOM-210.FD.S-SOFT PC Communication software for Remote control and Programming

Fail MonitoringEmergency stopMultiple engage failFailed to startLow oil pressureHigh temperatureSpeed failureVoltage failureCharging failSpare-1, 2, 3

ErrorSpare-4, 5, 6Over / Under speedSpeed lossEarth faultFuel levelBattery lowBattery highMaintenanceOver currentShort circuitEngine stop

Pre-AlarmEngine temperatureOver / Under voltageOver / Under frequencyOver / Under speedOil pressureFuel level

Warning & Electrical tripReverse powerEarth faultOver currentShort circuit

AlarmMains breaker not openedMains breaker not closedGenerator breaker not openedGenerator breaker not closed

ControlsFuel and Stop solenoidStarter motorAutomatic generator startLoad transfer to mainsPreheatExternal alarm horn

Enhanced Automatic Gen-Set Controllerswith Transfer Switching

13

EAOM-210.FDJ

CanBus J1939 ECU communication

Remote control via RS-232 ModBus or dial-up modem,

Authorised access, secure communication,

Automatic transfer switching control and engine control,

Logs last 50 events & alarm informations,

Remote Start/Stop, Speed and Idle mode control via J1939 for Volvo EMS2

Power factor measurement for 3 phases

SPN, FMI and OC values reading from engine via J1939

3 phase mains and 3 phase generator voltage measurement,

3 phase load current and earth current measurement,

Contactor open and close relay outputs for mains and generator,

Configurable 6 inputs and 4 outputs,

3 resistive sender inputs for oil pressure, temperature and level,

Speed sensing from alternator voltage or magnetic pickup,

Stop or fuel solenoid selection,

Maintenance warning (working hour or elapsed month),

Exercise at programmed time intervals,

OFF, Manual, Auto and Test mode,

Power measurement by kVA, kW, kVAr, kVAh, kWh, kVArh,

Compatible to Diesel or Gas generators,

144x204 mm size, Flat type

CanBus J1939 ECUcommunication

Enhanced Automatic Gen-Set Controllerswith Transfer Switching

14

EAOM-210.FDJ

Sta

rt

Sol

enoi

d

Tem

pera

ture

Oil

Pre

ssur

e

Leve

l

Bat

tery

vol

tage

Mag

netic

Pic

kup

(RP

M)

Relayoutputs

Analogue inputs

4 configurablerelay outputs

6 configurabledigital inputs

Engine Control

Digital inputs

+Vba

t

-Vba

t

-Vba

t

D+(

W.L

.)

Cha

rge

Gen

.

E.S

top

Generator Mains

Contactoropen / close

8-32VdcSupply voltage

CommunicationRS-232

ModBus RTU

5S

tart

Sol

enoi

d

Tem

pera

ture

Oil

Pre

ssur

e

Leve

l

Bat

tery

vol

tage

Mag

netic

Pic

kup

(RP

M)

Relayoutputs

Analogue inputs

2 configurablerelay outputs

6 configurabledigital inputs

Engine Control

Digital inputs

+Vba

t

-Vba

t

-Vba

t

D+(

W.L

.)

Cha

rge

Gen

.

E.S

top

Generator Mains

Contactor

8-32VdcSupply voltage

CommunicationRS-232

ModBus ASCIIor RTU

5

Contactor

2

Can

Bus

J19

39E

CU

com

mun

icat

ion

Can

Bus

J19

39E

CU

com

mun

icat

ion EAOM-210.FDJ.S

EAOM-210.FDJ

Order information

EAOM-210.FDJ Enhanced automatic Gen-Set controller with transfer switching, LED display, J1939 ECU comm.

EAOM-210.FDJ.S Automatic Gen-Set controller with transfer switching, LED display, J1939 ECU comm.

MODEM-EXR V.32bis / 14.000bps Dial-up Modem unit, DIN rail mounting type, including 2mRS-232 cable (for connection to RS-232 port of EAOM-210.FD) 8-32Vdc supply voltage

ENCV-232/485-EXR RS-232 / RS-485 Convertor unit, DIN rail mounting type, including 2m RS-232 cable(for connection to RS-232 port of EAOM-210.FD), 1000V galvanic insulation, 8-32Vdc supply voltage

EAOM-210.FDJ-SOFT PC Communication software for Remote control and Programming

EAOM-210.FDJ.S-SOFT PC Communication software for Remote control and Programming

CanBus J1939 ECUcommunication

Automatic Gen-Set Controllerswith Transfer Switching

15

EAOM-9F

ControlsFuel and Stop solenoidStarter motorAutomatic generator startLoad transfer to mainsMains and Generator contactorPreheatExternal alarm horn

Monitors3-phase mains voltageAlternator voltageAlternator frequencyEngine speedBattery voltageEngine running timeError indicationProgram parameters

Fail MonitoringFailed to startLow oil pressureHigh temperatureOver speed failureVoltage failureCharging failOver CurrentSpare-1, 2

Sta

rt

Sol

enoi

d

Mag

netic

Pic

kup

(RP

M)Transistor

outputs

Transistoroutputs

2 configurabledigital inputs

Engine Control

Digital inputs

-Vba

t

-Vba

t

D+(

W.L

.)

Cha

rge

Gen

.

E.S

top

Generator Mains

Contactor

8-32VdcSupply voltage

CommunicationRS-232

2

-Vba

tLo

w o

il pr

essu

re

-Vba

tH

igh

tem

pera

ture

-Vba

tO

ver c

urre

nt -Vba

tR

emot

e in

hibi

t

Bat

ery

volta

ge

Hor

n O

utpu

t

Con

figur

able

outp

ut

Contactor

Order information

EAOM-9F Automatic Gen-Set controller with transfer switching, LED display

MODEM-EXR V.32bis / 14.000bps Dial-up Modem unit, DIN rail mounting type, including 2m RS-232 cable(for connection to RS-232 port of EAOM-9F) 8-32Vdc supply voltage

EAOM-9F-SOFT PC Communication software for Remote control and Programming

Remote control via RS-232 or standard modem communication,

Automatic transfer switching control and engine control,

3 phase mains and 1 phase generator voltage measurement,

Contactor transistor outputs for mains and generator,

Configurable 2 inputs and 1 output,

Speed sensing from alternator voltage or magnetic pickup,

Stop or fuel solenoid selection,

Maintenance warning (working hour),

OFF, Manual, Auto and Test mode,

144x204 mm size, Flat type

Order information

EAOM-9 Automatic Gen-Set controller with transfer switching, LED display

EAOM-9-SOFT PC Communication software for Remote control and Programming

Sta

rt

Sol

enoi

d

Mag

netic

Pic

kup

(RP

M)

Relay outputs

Relayoutputs

2 configurabledigital inputs

Engine Control

Digital inputs

-Vba

t

-Vba

t

D+(

W.L

.)

Cha

rge

Gen

.

E.S

top

Generator Mains

Contactor

8-32VdcSupply voltage

CommunicationRS-232

2

-Vba

tLo

w o

il pr

essu

re

-Vba

tH

igh

tem

pera

ture

-Vba

tO

ver c

urre

nt -Vba

tR

emot

e in

hibi

t

Bat

ery

volta

ge

Hor

n O

utpu

t

Con

figur

able

outp

ut

Contactor

Automatic Gen-Set Controllerswith Transfer Switching

16

EAOM-9

ControlsFuel and Stop solenoidStarter motorAutomatic generator startLoad transfer to mainsMains and Generator contactorPreheatExternal alarm horn

Monitors3-phase mains voltageAlternator voltageAlternator frequencyEngine speedBattery voltageEngine running timeError indicationProgram parameters

Fail MonitoringFailed to startLow oil pressureHigh temperatureOver speed failureVoltage failureCharging failOver CurrentSpare-1, 2

Automatic transfer switching control and engine control,

3 phase mains and 1 phase generator voltage measurement,

Contactor relay outputs for mains and generator,

Configurable 2 inputs and 1 output,

Speed sensing from alternator voltage or magnetic pickup,

Stop or fuel solenoid selection,

Maintenance warning (working hour),

OFF, Manual, Auto and Test mode,

96x96 mm size,

Automatic transfer switching control and engine control,

3 phase mains and 1 phase generator voltage measurement,

Contactor relay outputs for mains and generator,

Configurable 2 inputs and 1 output,

Speed sensing from alternator voltage,

Stop and fuel solenoid selection,

OFF, Manual, Auto and Test mode,

Diesel or Gasoline engine control,

Remote inhibit input,

Adjustable choke time,

Low oil level or pressure input,

Provides charge generator excitation current,

Easy to use and economical,

72x72 mm size,

Automatic Gen-Set Controllerswith Transfer Switching

17

EAOM-19

ControlsFuel and Stop solenoidStarter motorAutomatic generator startLoad transfer to mainsMains and Generator contactorExternal alarm horn

Monitors3-phase mains voltageAlternator voltageAlternator frequencyEngine speedBattery voltageError indicationProgram parameters

Fail MonitoringFailed to startLow oil pressureHigh temperatureOver speed failureVoltage failureCharging failOver CurrentSpare-1, 2

Order information

EAOM-19 Automatic Gen-Set controller with transfer switching, LED display

Sta

rt

Sol

enoi

d

Relay outputs

Relayoutputs

2 configurabledigital inputs

Engine Control

Digital inputs

-Vba

t

D+(

W.L

.)

Cha

rge

Gen

.

Generator Mains

Contactor

8-32VdcSupply voltage

2

-Vba

tLo

w o

il pr

essu

re

-Vba

tH

igh

tem

pera

ture

Bat

ery

volta

ge

Con

figur

able

outp

ut

Contactor

Model EAOM-36 EAOM-6 EAOM-7 EAOM-71 EAOM-72F

Dimensions (mm) 72X72 96x96 96x96 96x96 144x204

Display LED LED LED LED LED

Generator No L1/L2, L1/N L1/L2, L1/N L1/L2, L1/N L1/L2, L1/NVoltage L2/L3, L2/N L2/L3, L2/N L2/L3, L2/N L2/L3, L2/NMeasurement L3/L1, L3/N L3/L1, L3/N L3/L1, L3/N L3/L1, L3/N

Generator No No kVA kVA kVAPowerMeasurement

Load Current No No IL1, IL2, IL3 IL1 IL1, IL2, IL3Measurement

Earth Current No No No No NoMeasurement

Outputs Start, Fuel, Horn, Start, Fuel, Horn, Start, Fuel, Horn, Start, Fuel, Horn, Start, Fuel, Horn,

Configurable 1 User Configurable 2 User Configurable 2 User Configurable 2 User Configurable 2 User ConfigurableOutputs

Configurable 2 User Configurable 3 User Configurable 3 User Configurable 3 User Configurable 3 User Configurable,Inputs

Outputs Type Relay or Solid State Relay Relay Relay Solid State

Analogue No No No Oil Pressure Oil PressureResistive Fuel Level Fuel LevelSender Inputs Temperature Temperature

Speed Sensing From Alternator From Alternator signal From Alternator signal From Alternator signal From Alternator signalsignal or magnetic pickup or magnetic pickup or magnetic pickup or magnetic pickup

Passwords Operator & Operator & Operator & Operator &Technician Technician Technician Technician Technician

Timer Timer Timer Timer Timer Timer

Engine Running Yes Yes Yes Yes YesTime

Communication RS-232 Serial RS-232 Serial RS-232 Serial RS-232 Serial RS-232 Serial

Auto Start Gen-SetProtection & Controllers

18

Comparison Table

Auto Start Gen-SetProtection & Controllers

19

EAOM-72F

ControlsFuel and Stop solenoidStarter motorAutomatic generator start/stopPreheatExternal alarm horn

Monitors3-phase alternator voltage3-phase load currentAlternator frequencyEngine speedGenerator Power (kVA)Oil pressureEngine temperatureFuel levelBattery voltageEngine running timeError indicationProgram parameters

Fail MonitoringAlternator voltage & frequencyFailed to startLow oil pressureHigh temperatureOver / Under speed failureOver currentCharging failEmergency stopMaintenance dueSpare-1, 2, 3

Order information

EAOM-72F Auto Start Gen-Set protection and controller, LED display

EAOM-72F-SOFT PC Communication software for Remote control and Programming

Sta

rt

Sol

enoi

d

Tem

pera

ture

Oil

Pre

ssur

e

Leve

l

Bat

tery

vol

tage

Mag

netic

Pic

kup

(RP

M)

SolidState

outputs

Analogueinputs

3 configurabledigital inputs

Engine Control

Digital inputs

-Vba

t

-Vba

t

-Vba

t

D+(

W.L

.)

Cha

rge

Gen

.

E.S

top

Generator

8-32VdcSupply voltage

CommunicationRS-232

3Rem

ote

Sta

rt / S

top

Transistoroutputs

Hor

n O

utpu

t

2 C

onfig

urab

leou

tput

s

-Vba

tLo

w o

il pr

essu

re

-Vba

tH

igh

tem

pera

ture

2

Automatic engine control,

3 phase generator voltage measurement,

3 phase Load current measurement,

Generator power measurement by kVA,

3 Resistive sender inputs for Temperature, Oil Pressure and Level,

Configurable 3 inputs and 2 outputs,

Remote Start/Stop input,

Speed sensing from alternator voltage or magnetic pickup,

Over / Under speed warning and shutdown,

Stop or fuel solenoid selection,

Solenoid output switched negative or positive supply,

Maintenance warning,

144x204 mm size, Flat type

Sta

rt

Sol

enoi

d

Tem

pera

ture

Oil

Pre

ssur

e

Leve

l

Bat

tery

vol

tage

Mag

netic

Pic

kup

(RP

M)

Relayoutputs

Analogueinputs

Engine Control

Generator

8-32VdcSupply voltage

CommunicationRS-232

3 configurabledigital inputsDigital inputs

-Vba

t

-Vba

t

-Vba

t

D+(

W.L

.)

Cha

rge

Gen

.

E.S

top

3Rem

ote

Sta

rt / S

top

-Vba

tLo

w o

il pr

essu

re

-Vba

tH

igh

tem

pera

ture

Relayoutputs

Hor

n O

utpu

t

2 C

onfig

urab

leou

tput

2

Order information

EAOM-71 Auto Start Gen-Set protection and controller, LED display

EAOM-71-SOFT PC Communication software for Remote control and Programming

Auto Start Gen-SetProtection & Controllers

20

EAOM-71

ControlsFuel and Stop solenoidStarter motorAutomatic generator start/stopPreheatExternal alarm horn

Monitors3-phase alternator voltage1-phase load currentAlternator frequencyEngine speedGenerator Power (kVA)Oil pressureEngine temperatureFuel levelBattery voltageEngine running timeError indicationProgram parameters

Fail MonitoringAlternator voltage & frequencyFailed to startLow oil pressureHigh temperatureOver / Under speed failureOver currentCharging failEmergency stopMaintenance dueSpare-1, 2, 3

Automatic engine control,

3 phase generator voltage measurement,

1 phase Load current measurement,

Generator power measurement by kVA,

3 Resistive sender inputs for Temperature, Oil Pressure and Level,

Configurable 3 inputs and 2 outputs,

Remote Start/Stop input,

Speed sensing from alternator voltage or magnetic pickup,

Over / Under speed warning and shutdown,

Stop or fuel solenoid selection,

Maintenance warning,

96x96 mm size,

Sta

rt

Sol

enoi

d

Bat

tery

volta

ge

Mag

netic

Pic

kup

(RP

M)Relay

outputsAnalogue

inputs

Engine Control

Generator

8-32VdcSupply voltage

CommunicationRS-232

3 configurabledigital inputsDigital inputs

-Vba

t

-Vba

t

-Vba

t

D+(

W.L

.)

Cha

rge

Gen

.

E.S

top

3Rem

ote

Sta

rt / S

top

-Vba

tLo

w o

il pr

essu

re

-Vba

tH

igh

tem

pera

ture

Relayoutputs

Hor

n O

utpu

t

2 C

onfig

urab

leou

tput

2

IL1, IL2,IL3

Auto Start Gen-SetProtection & Controllers

21

EAOM-7

ControlsFuel and Stop solenoidStarter motorAutomatic generator start/stopPreheatExternal alarm horn

Monitors3-phase alternator voltage3-phase load currentAlternator frequencyGenerator power (kVA)Engine speedBattery voltageEngine running timeError indicationProgram parameters

Fail MonitoringAlternator voltage & frequencyFailed to startLow oil pressureHigh temperatureOver / Under speed failureOver currentCharging failEmergency stopMaintenance dueSpare-1, 2, 3

Order information

EAOM-7 Auto Start Gen-Set protection and controller, LED display

EAOM-7-SOFT PC Communication software for Remote control and Programming

Automatic engine control,

3 phase generator voltage measurement,

3 phase Load current measurement,

Generator power measurement by kVA,

Configurable 3 inputs and 2 outputs,

Remote Start/Stop input,

Speed sensing from alternator voltage or magnetic pickup,

Over / Under speed warning and shutdown,

Stop or fuel solenoid selection,

Maintenance warning,

96x96 mm size,

Order information

EAOM-6 Auto Start Gen-Set protection and controller, LED display

EAOM-6-SOFT PC Communication software for Remote control and Programming

Sta

rt

Sol

enoi

d

Bat

tery

volta

ge

Mag

netic

Pic

kup

(RP

M)Relay

outputsAnalogue

inputs

Engine Control

Generator

8-32VdcSupply voltage

CommunicationRS-232

3 configurabledigital inputsDigital inputs

-Vba

t

-Vba

t

-Vba

t

D+(

W.L

.)

Cha

rge

Gen

.

E.S

top

3Rem

ote

Sta

rt / S

top

-Vba

tLo

w o

il pr

essu

re

-Vba

tH

igh

tem

pera

ture

Relayoutputs

Hor

n O

utpu

t

2 C

onfig

urab

leou

tput

2

Auto Start Gen-SetProtection & Controllers

22

EAOM-6

ControlsFuel and Stop solenoidStarter motorAutomatic generator start/stopPreheatExternal alarm horn

Monitors3-phase alternator voltageAlternator frequencyEngine speedBattery voltageEngine running timeError indicationProgram parameters

Fail MonitoringAlternator voltage & frequencyFailed to startLow oil pressureHigh temperatureOver / Under speed failureCharging failEmergency stopMaintenance dueSpare-1, 2, 3

Automatic engine control,

3 phase generator voltage measurement,

Configurable 3 inputs and 2 outputs,

Remote Start/Stop input,

Speed sensing from alternator voltage or magnetic pickup,

Over / Under speed warning and shutdown,

Stop or fuel solenoid selection,

Maintenance warning,

96x96 mm size,

Auto Start Gen-SetProtection & Controllers with Key Switch

23

EAOM-36

ControlsFuel and Stop solenoidStarter motorAutomatic generator start/stopPreheatExternal alarm horn

MonitorsAlternator frequencyEngine speedEngine running timeError indicationProgram parameters

Fail MonitoringFailed to startLow oil pressureHigh temperatureOver / Under speed failureCharging failSpare-1, 2

Sta

rt

Sol

enoi

d

for EAOM-36.RFRelay outputs

Engine Control

Generator

8-32VdcSupply voltage

2 configurabledigital inputsDigital inputs

-/+V

bat

-Vba

t

D+(

W.L

.)

Cha

rge

Gen

.

2Rem

ote

Sta

rt / S

top

-Vba

tLo

w o

il pr

essu

re

-Vba

tH

igh

tem

pera

ture

for E

AO

M-3

6.R

F

Con

figur

able

outp

ut

L1,N

relay output

for E

AO

M-3

6.TF

Con

figur

able

outp

ut

solid stateoutput

-Vba

t

Sta

rt

Sol

enoi

d

for EAOM-36.TFSolid state

outputs

FAIL

SA

FE A

pplic

atio

n

Order information

EAOM-36.R Auto Start Gen-Set protection and controller, LED display, with relay outputs

EAOM-36.T Auto Start Gen-Set protection and controller, LED display, with solid state outputs (pulling to -BAT)

EAOM-36.RF Auto Start Gen-Set protection and controller, LED display, with relay outputs and fail safe inputs

EAOM-36.TF Auto Start Gen-Set protection and controller, LED display, with solid state outputs (pulling to -BAT)and fail safe inputs

Sta

rt

Sol

enoi

d

for EAOM-36.RRelay outputs

Engine Control

Generator

8-32VdcSupply voltage

2 configurabledigital inputsDigital inputs

-/+V

bat

-Vba

t

D+(

W.L

.)

Cha

rge

Gen

.

2Rem

ote

Sta

rt / S

top

-Vba

tLo

w o

il pr

essu

re

-Vba

tH

igh

tem

pera

ture

for E

AO

M-3

6.R

Con

figur

able

outp

ut

L1,N

relay output

for E

AO

M-3

6.T

Con

figur

able

outp

ut

solid stateoutput

-Vba

t

Sta

rt

Sol

enoi

d

for EAOM-36.TSolid state

outputs

Remote start / stop capability with zero power consumption,

Designed for Generator, Pump and Fire Pump applications,

Automatic engine control,

Automatic shutdown on fault condition

Generator frequency measurement,

Configurable 2 inputs and 1 output,

Remote Start/Stop input,

Speed sensing from alternator voltage,

Over / Under speed warning and shutdown,

Stop or fuel solenoid selection,

72x72 mm size

Sta

rt

Sol

enoi

d

Pre

heat

Engine ControlALT

Alternatorvoltage 8-32Vdc

Supply voltage

Digital inputs

-Vba

t

D+(

W.L

.)

Cha

rge

Gen

.

Aux

iliar

y sh

utdo

wn

-Vba

tLo

w o

il pr

essu

re

-Vba

tH

igh

tem

pera

ture

L1,N

tachometer output(0...1mA)

for ALT and MAGseries

MAGMagneticPickup

-Vba

tA

ux2

inpu

t for

STP

ser

ies

Manual Key Start & Engine Protectionwith Key Switch

24

EAOM-3

ControlsFuel and Stop solenoidStarter motorManual generator start/stopPreheat

MonitorsEngine running timeError indication

Fail MonitoringLow oil pressureHigh temperatureOver speed failureCharging fail

Order informationOverspeed sensing from generator voltage + + + +Overspeed sensing from magnetic pickup + + + +Time meter + + + + + +Stop button + + + + + +Stop/Fuel selection + + + + + +Preheat + + + + + + + + + + + +Aux.In-1 + + + + + + + + + + + +Aux.In-2 + + + + + +

Pro

duct

cod

es

EA

OM

-3

EA

OM

-3-A

LT

EA

OM

-3-M

AG

EA

OM

-3-H

M

EA

OM

-3-H

M-A

LT

EA

OM

-3-H

M-M

AG

EA

OM

-3-S

TP

EA

OM

-3-S

TP-A

LT

EA

OM

-3-S

TP-M

AG

EA

OM

-3-H

M-S

TP

EA

OM

-3-H

M-S

TP-A

LT

EA

OM

-3-H

M-S

TP-M

AG

Automatic shutdown on fault condition,

Alarm and status information,

Auxiliary shutdown input,

Provides charge alternator excitation current,

Over speed protection option with tachometer metering output,

Optional tamper-proof elased time meter,

Optional stop button,

72x72mm size

Automatic Transfer Switch

25

ATS-10

ControlsGenerator remote startLoad transfer to mainsMains and Generator contactor

Monitors3-phase mains voltageAlternator voltageProgram parameters

Order information

ATS-10 Automatic transfer switch, LED display

Digital inputs

Generator Mains

Contactor

8-32VdcSupply voltage

+Vba

tE

ngin

e ru

nnin

g

Rem

ote

Sta

rtou

tput

Contactor

+Vba

tLo

ad G

ener

ator

3 phase Mains voltage measurement,

Single phase Generator voltage measurement,

Optional Load Generator input,

Optional engine running input,

Mains voltage failure detection,

Remote start output,

Emergency backup and Test mode,

Password protection,

72x72 mm size,

Enhanced Automatic Gen-Set Controllerswith Transfer Switching

26

EAOM-210.FL.EXR

Order information

EAOM-210.FL-EXR I/O Expansion Board which is DIN rail mounting type, including 2m CanBus cable

8 Configurable digital inputs

Selectable input signal hardware type (-Ve or +Ve)

Selectable input signal polarity (Close or Open to activate)

User selectable 21 defined input configurations for each input

8 Configurable relay outputs

Selectable output polarity (NO or NC)

User selectable 93 defined functions for each output

DIN Rail mounting type

Communication to EAOM-210.FL, EAOM-210.FL.S, EAOM-210.FLJ or EAOM-210.FLJ.S by CanBus connection

8-32Vdc supply voltage

Battery Charger

27

GENCHARGER

Order information

GENCHARGER-312E SMPS Battery Charger, 3A Output for 12Vdc battery, 230Vac supply voltage

GENCHARGER-312A SMPS Battery Charger, 3A Output for 12Vdc battery, 115Vac supply voltage

GENCHARGER-512E SMPS Battery Charger, 5A Output for 12Vdc battery, 230Vac supply voltage

GENCHARGER-512A SMPS Battery Charger, 5A Output for 12Vdc battery, 115Vac supply voltage

GENCHARGER-324E SMPS Battery Charger, 3A Output for 24Vdc battery, 230Vac supply voltage

GENCHARGER-324A SMPS Battery Charger, 3A Output for 24Vdc battery, 115Vac supply voltage

GENCHARGER-524E SMPS Battery Charger, 5A Output for 24Vdc battery, 230Vac supply voltage

GENCHARGER-524A SMPS Battery Charger, 5A Output for 24Vdc battery, 115Vac supply voltage

3A or 5A output for 12Vdc and 24Vdc battery

115Vac or 230Vac supply voltage

Short circuit and over current protection

Reverse connection protection

Boost output for quick charging

Durability for voltage fluctuation

Flame resistance plastic box

for long battery life

Company Profile

28

EMKO ELEKTRONIK A.S. has been engaged in the desing, manufacture and

marketing of Measurement and Control Instruments and Temperature Sensors, as

well as in providing the relevant before and after sales technical service since 1986.

Giving the most importance to the customer-oriented approach and to product

functionality and quality, we have carried out the design and manufacture of

programmable multi-function process-control instruments, counters, time-relays,

thermocouples and thermoresistances, control and protection generating system;

gen-set controls, automatic transfer switching, manual-keystarts.

Our product range and service meet the needs of the textile, food, plastic,

glass, automotive, chemicals, iron and steel, cement, machinery production, energy

and other sectors, with regard to the automation and process-control materials and

services that they require. Thanks to the quality policy and procedures issued by

the management of our company, which processes in the TS ISO EN9001 Quality

System Certificate, complete customer satisfaction in the areas of design, production

and service is quaranteed. The design and manufacture of control devices conformed

to the directives covered by the CE brand by performing the

EMI, ESD, EFT, PQF, Surge, LVD, Environmental Conditions tests

on new product designs in the test laboratories on our factory premises.

The following design issues are experimented with in our company:

- Process measurement and control instruments which conform to industrial

standards

- The measurement conversion and control of process parameters in such areas

as temperature, pressure, weight, flow, level, speed, humidity, number,

time, voltage and current etc.

- Temperature sensors , thermocouples and thermores is tances

- Control and protection generating systems; Gen-Set controls, Automatic Transfer

Switchings, Manual-keystarts

Our ‘‘Customer Support Service’’ provides pleasant, cheerful and sincere

approach to ensure that our customers select the most suitable products by providing

satisfactory and correct technical information before the sale and if the orders are

delivered correctly on time by keeping track of orders within the company. Also,

guarantees customer satisfaction at all times, in all places and under all circumstances

by supplying them with speedy and reliable information through our authorized

dealer and service network.