Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
ARCHITECTS
GCPS: ACCIDENT ELEMENTARY SCHOOLVESTIBULE MODIFICATIONS
VICINITY MAP LOCATION MAPNOT TO SCALENOT TO SCALE
GC
PS: A
CC
IDE
NT
EL
EM
EN
TA
RY
SC
HO
OL
VE
STIB
UL
E M
OD
IFIC
AT
ION
SB
FM #
200
02
MA
RC
H 1
3, 2
020
AC
CID
EN
T, M
AR
YL
AN
D
DRAWING INDEXCS-1 COVER SHEET
ARCHITECTURAL:
D1.1 DEMO FLOOR PLAN
ELECTRICAL:
E1.1 DEMO ELECTRICAL PLAN
PSC No. 11.012.20
534 ACCIDENT BITTINGER RD.ACCIDENT, MD 21520
MARCH 13, 2020 A1.1 FLOOR PLAN
A2.1 SCHEDULE
A2.2 DOOR & WINDOW DETAILS
A8.1 CEILING PLAN
E1.2 NEW ELECTRICAL PLAN
A6.1 INTERIOR ELEVATIONS
D1.1 DEMO CEILING PLAN
GCPS BID No. AC20-01
PRINCIPAL(E)
GENERAL OFFICE(E)
HEALTH(E)
WORK / STORAGE(E)
WOMEN(E) MEN(E)
CAFETERIA(E)
TEACHER LOUNGE(E)
3
3
3
3
4 1A
1A
1A
1
1
1 1
11
6
5
2
VAULT(E)
10
(E) T.B.
11
113
13
(E) DESK
(E) WALL HEATER
(E) SHELF
7
(E) F
.C.
(E) F
.C.
(E) BED
(E) DESK(E
) BED
12
1212
12
(E) WALLHEATER
(E) WALL HEATER
12
7 14
15
5
7
(E) DESK
(E) BEAM ABOVE
3
4'-5
"2'
-8"
2'-8
"8'
-6"
(E) INTERCOM
15
(E) BENCH RELOCATEAS REQ'D
(E) BENCH
2
DOOR RELOCATEDTOO DOOR NUMBER107 - SEE NEW PLAN
DOOR RELOCATEDTOO DOOR NUMBER105 - SEE NEW PLAN
DOOR RELOCATEDTOO DOOR NUMBER105A - SEE NEW PLAN
(E) VCT
(E) VCT
(E) VCT
(E) VCT
(E) CARPET
(E) CARPET
8
CONF. ROOM(E)
(E) WALL HEATER- REMOVE & CAP ELECT. FEED
(E) F.E.
(E) PULL STATION
(E) STROBE
(E) FIRST AID KITS
16
(E) T.B.
14
(E) TERRAZZO
CORRIDOR(E)
97 3'-4
"3'
-4"
4" 3'-4"
4"3'-4"
4" 3'-4"
NOTE: CONTRACTOR TO PATCH AND REPAIR AREASWHERE ELECTRICAL OUTLETS/DEVICES OR OTHERITEMS ARE REMOVED FROM WALL/CEILINGS, MATCHADJACENT FINISHES - TYP. ALL AREAS OF WORK
16
(E) CANOPY ABOVELINE OF (E) BULKHEAD ABOVE
DEMOLITION NOTES
REMOVE (E) DOOR UNIT FRAME & FRAMEGLAZING AS SHOWN- PATCH & REPAIRADJACENT WALLS & FLOOR AS REQUIRED.
REMOVE (E) DOOR & FRAME - RELOCATE DOORPER DOOR SCHEDULE
REMOVE (E) CEILING MATERIAL - PATCH & REPAIRADJACENT WALLS AS REQUIRED. - SEE SHT. D8.1
REMOVE (E) MTL STUD & GYP BD. WALL - PATCH& REPAIR ADJACENT WALLS & FLOOR ASREQUIRED.
REMOVE AND RELOCATE (E) TV ANDASSOCIATED EQUIPMENT - PATCH AND REPAIRADJACENT FINISHES AS REQUIRED
REMOVE (E) CASEWORK - PATCH AND REPAIRADJACENT FINISHES AS REQUIRED
REMOVE AND RELOCATE (E) MAILBOXES- PATCH AND REPAIR ADJACENT FINISHES ASREQUIRED
REMOVE (E) TACK BOARD - PATCH AND REPAIRADJACENT FINISHES AS REQUIRED
REMOVE & RELOCATE (E) REFRIGERATOR -PATCH & REPAIR ADJACENT FINISHES ASREQUIRED
REMOVE (E) WALL HEATER - REMOVE & CAPELECT. FEED - PATCH AND REPAIR ADJACENTFINISHES AS REQUIRED
REMOVE (E) WINDOW UNIT & FRAME - PATCH &REPAIR ADJACENT FINISHES AS REQUIRED
REMOVE & RELOCATED (E) CASEWORK - PATCHAND REPAIR ADJACENT FINISHES AS REQUIRED
REMOVE (E) WALLPAPER, PATCH & REPAIRSURFACE, SKIM COAT, & PREP FOR PAINT
REMOVE & RELOCATE (E) PRINTER & ALLASSOCIATED CONNECTIONS AND HARDWARE.- PATCH & REPAIR ADJACENT FINISHES ASREQUIRED
REMOVE (E) CARPET & PREPARE SLAB FOR NEWFLOORING SURFACE - WORK PER ALTERNATE
REMOVE & RELOCATE (E) BENCH
REMOVE & RELOCATE (E) BOX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1A
16
©
DRAW
ING
INTE
NT IS
TO
IN
DICA
TE G
ENER
AL
ARRA
NGEM
ENT,
DESI
GN
AND
INTE
NT O
F W
ORK
IS P
ARTL
Y DI
AGRA
MM
ATIC
. IT S
HALL
NO
T BE
SCA
LED
FOR
ROUG
H-IN
MEA
SURE
MEN
TS
OR
SERV
E AS
ERE
CTIO
N SH
OP
DRAW
ING
S.
CONT
RACT
OR
IS
RESP
ONS
IBLE
FO
R VE
RIFIC
ATIO
N O
F DI
MEN
SIO
NS
MAR
YLAN
D.TH
E LA
WS
OF
THE
STAT
E O
F
I CER
TIFY
THAT
THE
SE
LICEN
SED
ARCH
ITECT
UND
ER
BY M
E, A
ND T
HAT
I AM
A D
ULY
DOCU
MEN
TS W
ERE
EXPI
RATIO
N DA
TE
LICEN
SE N
o.
PREP
ARED
OR
APPR
OVE
D
100
11
7.7.
20
BID DOCUMENTS
XREF
S: T
ITLEB
L
2 0 2 4 6 8 101/4" = 1'-0"
SCALE FEET
1
D1.11/4" = 1'-0" KEY PLANNO SCALE
AREA OF WORK
(E) T.B.
32 1
1
1
3
4
5
CEILING DEMOLITION NOTES
REMOVE & RELOCATE (E) LIGHTING FIXTURES - PATCH &REPAIR ADJACENT FINISHES AS REQUIRED
REMOVE (E) LIGHTING FIXTURE - PATCH & REPAIRADJACENT FINISHES AS REQUIRED
REMOVE (E) CEILING MATERIAL - PATCH & REPAIRADJACENT WALLS AS REQUIRED. AREAS INDICATED BY
REMOVE & RELOCATE (E) SPEAKER - PATCH & REPAIRADJACENT FINISHES AS REQUIRED
REMOVE & RELOCATE (E) EXIST SIGN - PATCH & REPAIRADJACENT FINISHES AS REQUIRED
1
3
2
4
5
3
2
EXHAUST
RETURN
SUPPLY
LINEAR SUPPLY GRILL
GYP. BD. BULKHEAD
GYP. BD. CEILING
DUCT MOUNTEDSUPPLY GRILL
NEW 2' x 4' ACOUSTICALTILE AND GRID - HATCHED
FLUORESCENT RECESSEDLIGHT FIXTURE (EXISTING)
FLUORESCENT RECESSEDLIGHT FIXTURE (NEW)
12" Ø TRACK MOUNTEDPENDANT LIGHT FIXTURE
4' SURFACE MOUNTEDLIGHT FIXTURE
4' STRIP LIGHT FIXTURESUSPENDED ABOVETRANSLUCENT PANELS
DOWN LIGHT
1x2 WALL MOUNTEDLIGHT FIXTURE
EXIT SIGN - SINGLE SIDEDEXIT SIGN - DOUBLE SIDED
12" Ø DECORATIVE PENDANTLIGHT FIXTURE
SOFFIT PANELS
WALL MOUNTED LIGHT
EMERGENCY LIGHTING
(E) 2' x 4' ACOUSTICALTILE AND GRID
(E) DOWN LIGHT
4' SURFACE MOUNTEDLIGHT FIXTURE (EMERGENCY)
SPEAKERSPRINKLER HEAD (EXISTING)
©
DRAW
ING
INTE
NT IS
TO
IN
DICA
TE G
ENER
AL
ARRA
NGEM
ENT,
DESI
GN
AND
INTE
NT O
F W
ORK
IS P
ARTL
Y DI
AGRA
MM
ATIC
. IT S
HALL
NO
T BE
SCA
LED
FOR
ROUG
H-IN
MEA
SURE
MEN
TS
OR
SERV
E AS
ERE
CTIO
N SH
OP
DRAW
ING
S.
CONT
RACT
OR
IS
RESP
ONS
IBLE
FO
R VE
RIFIC
ATIO
N O
F DI
MEN
SIO
NS
MAR
YLAN
D.TH
E LA
WS
OF
THE
STAT
E O
F
I CER
TIFY
THAT
THE
SE
LICEN
SED
ARCH
ITECT
UND
ER
BY M
E, A
ND T
HAT
I AM
A D
ULY
DOCU
MEN
TS W
ERE
EXPI
RATIO
N DA
TE
LICEN
SE N
o.
PREP
ARED
OR
APPR
OVE
D
100
11
7.7.
20
BID DOCUMENTS
XREF
S: T
ITLEB
L
2 0 2 4 6 8 101/4" = 1'-0"
SCALE FEET
1
D8.11/4" = 1'-0" KEY PLANNO SCALE
AREA OF WORK
2
D8.11/4" = 1'-0"
WOMEN(E) MEN(E)
CAFETERIA(E)
TEACHER LOUNGE(E)
103
101
105
105A
107
106
102A
MAILBOXES
NEW COUNTER- PER ALT. 2
VAULT(E)
VESTIBULE101
VESTIBULE103
LOBBY104
PRINCIPA.L105
WORK / STORAGE106
HEALTH107
4'-0"3'-4"3'-0"
3'-4
"
6'-4"
4"
(E) T.B.
(E) WALL HEATER
(E) SHELF
(E) F
.C.
(E) F
.C.
(E) BED
(E) DESK(E
) BED
(E) WALLHEATER
(E) WALL HEATER
W2
RELOCATEDCASEWORK
RELOCATEDBENCH
(E) DESK
RELOCATED COPIER
EXTEND (E) WALL ABOVEDOORS TO DECK ABOVE- VERIFY CONSTRUCTIONIN FIELD
EXTEND (E) WALL ABOVEDOORS TO DECK ABOVE- VERIFY CONSTRUCTIONIN FIELD
(E) BEAM ABOVE
W2
W3
102
104A104
3'-0
"
3'-0"
P-1
(E) INTERCOM
RELOCATEDDESKRELOCATED
CASEWORK
RELOCATEDCASEWORK
(E) BENCH RELOCATEAS REQ'D
(E) BENCH
CONF. ROOM(E)
ADA
ADA
6'-0"
RELOCATEDT.B.
RELOCATEDREFRIGERATOR
5'-0
"
4'-6 1/2"
NEW MTL.TRANSITION STRIP
ADA
1A6.1
6'-0"
(E) F.E.
(E) PULL STATION
(E) STROBE
(E) FIRST AID KITS
4A6.1
11'-4"
2'-6
"(E) T.B.
NEW CARPET
1'-2"
3'-4
"4'
-5"
ADA
13'-1
0 1/
2"
GENERAL OFFICE108
108
NEW
CA
RPET
RELOCATEDBENCH
CRADA
RELOCATED A-PHONE
(E) TERRAZZO
P-2
5'-0"
2A6.1
-
C
B
A
CORRIDOR(E)3'-4"4"
3'-4"
ADA
ADA
NEW MTL.THRESHOLD
(E) CANOPY ABOVE
CR
RELOCATED SHELF& CLOCK SYSTEM
3'-4" 4"
NEW KNOX BOXMOUNTED @ 7'-0" A.F.F.
RELOCATED BOX
P-1
(E) V
CT
(E) VCT
(E) V
CT
ADA
NEW PERFORATEDMTL PANEL
1A2.1
10'-2
"4
1/2"
19'-7
1/2"
6'-1
1 1/2
"
W2
ADA
VESTIBULE102
105A
107
106
WORK / STORAGE106
4"
(E) T.B.
(E) F
.C.
(E) BED
3'-0"
P-1
RELOCATEDCASEWORK
6'-0" 6'-0"
108STOR.109
(E) T.B.
ALT. No. 1
2A6.1
-
C
B
A
P-1
P-1
3'-4"4"
©
DRAW
ING
INTE
NT IS
TO
IN
DICA
TE G
ENER
AL
ARRA
NGEM
ENT,
DESI
GN
AND
INTE
NT O
F W
ORK
IS P
ARTL
Y DI
AGRA
MM
ATIC
. IT S
HALL
NO
T BE
SCA
LED
FOR
ROUG
H-IN
MEA
SURE
MEN
TS
OR
SERV
E AS
ERE
CTIO
N SH
OP
DRAW
ING
S.
CONT
RACT
OR
IS
RESP
ONS
IBLE
FO
R VE
RIFIC
ATIO
N O
F DI
MEN
SIO
NS
MAR
YLAN
D.TH
E LA
WS
OF
THE
STAT
E O
F
I CER
TIFY
THAT
THE
SE
LICEN
SED
ARCH
ITECT
UND
ER
BY M
E, A
ND T
HAT
I AM
A D
ULY
DOCU
MEN
TS W
ERE
EXPI
RATIO
N DA
TE
LICEN
SE N
o.
PREP
ARED
OR
APPR
OVE
D
100
11
7.7.
20
BID DOCUMENTS
XREF
S: T
ITLEB
L
2 0 2 4 6 8 101/4" = 1'-0"
SCALE FEET
1
A1.11/4" = 1'-0" KEY PLANNO SCALE
AREA OF WORKWALL FINISH KEY
C
AD B
2
A1.11/4" = 1'-0"
MAT'L.NO
DOOR
ROOM LOCATION SIZE TYPEREMARKS
DOOR SCHEDULEFRAME
TYPEGLAZ MAT'L. GLAZWIDTH JAMB THRSHEADHARD-WARE
SIGNAGE LABEL
101 VESTIBULE 3'-0" x 7'-0" 1 ALUM G7 C ALUM 4 1/2" G7 1 2 ALUM 1 THERMALLY BROKEN, BRONZE ( )
DETAILSSEE SHEET A2.2
1" INSULATED TEMPERED GLASS UNITS
DESCRIPTION
NOT USED
3/8" LAMINATED SAFETY GLASS- CLEAR
G-7
G-6
G-5
G-4
G-3
G-2
G-1
TYPE
GLAZING LEGEND
NOT USED
NOT USED
NOT USED
NOT USED
INSULATED ALUM. PANELG-8
102 VESTIBULE (2) 3'-0" x 7'-0" 1 / 1 ALUM G7 C ALUM 4 1/2" G7 1 2 ALUM 3 THERMALLY BROKEN, BRONZEREMOVABLE MULLION
102A VESTIBULE 3'-0" x 7'-0" 1 ALUM G7 C ALUM 4 1/2" G7 1 2 ALUM 4 THERMALLY BROKEN, BRONZE ( )
103 VESTIBULE 3'-0" x 7'-0" 1 ALUM G7 B ALUM 4 1/2" G7 3 4 2 OFFICE (#) BRONZE ( )-
104 LOBBY (2) 3'-0" x 7'-0" 1 / 1 ALUM G7 D ALUM 4 1/2" G7 3 4 ALUM 3 BRONXEELECTRONIC LOCKSET
104A LOBBY 3'-0" x 7'-0" 1 ALUM G7 D ALUM 4 1/2" G7 3 4 ALUM 4 BRONZE : CARD READER / ADATIME CLOCK ( )
105 PRINCIPAL 3'-0" x 7'-0" (E) 2 SC WD - A HM 5 1/2" - 5 6 ALUM 5 PRINCIPAL (#) DOOR FROM PRINCIPAL
105A PRINCIPAL 3'-0" x 7'-0" (E) 2 SC WD - A HM 5 1/2" - 5 6 ALUM 5 PRINCIPAL (#) DOOR FROM HEALTH ROOM
106 WORK / STORAGE 3'-0" x 7'-0" (E) 2 SC WD - A HM 5 1/2" - 5 6 ALUM 5 CONFERANCE (#) DOOR FROM LOBBY
107 HEALTH 3'-0" x 7'-0" 2 SC WD - A HM 5 1/2" - 5 6 ALUM 5 HEALTH (#) --
109 STORAGE (ALTERNATE) 3'-0" x 7'-0" 2 SC WD - A HM 5 1/2" - 5 6 ALUM 6 STORAGE (#) 1 HR ALTERNATE No. 1-
108 GENERAL OFFICE 3'-0" x 7'-0" (E) 2 SC WD - A (E) HM 5 1/2" - 5 6 - 7 - NEW CLOSER-
# MATCH EXISTING SIGNAGE
· DOOR CONTROLS, CARD READER, ADABUTTON, TIME ZONE OR REMOTE RELEASE
- COORDINATE w/ HARDWARE
Ω ELECTRICAL REQUIREMENTS
Ω
ROOM FINISH SCHEDULEWALLFLOORNAMENO BASE
A B
CEILING
C D MAT'L HT
REMARKS
101 VESTIBULE F1 / F2 B1 / B4 / B5 W4 / W5 W4 / W5 W5 W2 / W4 C1 / C3 V.I.F. TILE WAINSCOT - MATCH EXIST. HT.
F1 B1 W1 C1
F2
F3
LEGENDFLOORS BASE WALLS CEILINGS
EXISTING BRICK EXISTING ACOUSTICAL CLG TILEEXIST GYP BD - PAINT
W2 EXISTING BRICK
NEW WALK OFF MAT (BY OWNER)
EXISTING TERRAZZO
W3 EXISTING WALL TILE - V.I.F.
C2 EXISTING VINYL SOFFIT B2
B3
EXISTING VINYL BASE
EXISTING CARPET
102 VESTIBULE F1 / F2 B1 / B4 W5 W2 W4 / W5 W5 C1 V.I.F. -
103 VESTIBULE F2 B5 W4 / W5 W4 / W5 W5 W2 C1 V.I.F.PROVIDE MTL TRANSITION STRIP AT OPENING
104 LOBBY F2 B3 / B5 - W1 / W3 W4 / W5 W4 / W5 C1 / C3 V.I.F. PATCH & MATCH EXIST FINISHES
105 PRINCIPAL F3 B4 W1 / W4 W1 / W4 W1 W1 / W4 C1 V.I.F. NOTE No. 1 - NO WAISCOT
106 WORK / STORAGE F4 B2 W1 W1 W1 W1 C1 V.I.F. NOTE No. 1
107 HEALTH F4 B2 / B4 W1 W1 / W4 W1 W1 C1 V.I.F. NOTE No. 1
C3 ACOUSTICAL CLG TILE
W4 NEW GYP BD - w/ TILE WAINSCOT B4 NEW VINYL BASE
EXISTING TILE BASE
W5 STOREFRONT B5 NEW TILE BASE
108 GENERAL OFFICE F5 / F6 B2 / B3 / B4 W1 W3 / W4 W1 / W4 W1 / W4 C1 V.I.F. -
(E) CORRIDOR F4 B2 W1 - W1 W1 C1 V.I.F. -
(E) CONFERENCE ROOM F3 B2 W1 W1 W1 / W4 W1 C1 V.I.F. -
F4 EXISTING VCT
F5 NEW CARPET
F6 NEW VCT
NOTE No.1 : REMOVE EXIST. WALL PAPER,PATCH & REPAIR WALL SURFACE SKIM COATw/ JOINT COMPOUND, SMOOTH & PAINT
109 STORAGE (ALTERNATE) F4 B2 W1 W1 / W4 W1 W1 C1 V.I.F. NOTE No. 1
A
FRA
ME
TYPE
S
FIN.FLR.
B
SEE SCHED.
10"
SEE
SC
HED
ULE
7"
7" 7"
G-7
FIN.FLR.
DO
OR
TYPE
SW
IND
OW
TY
PES
G-7
2'-4
"8"
2'-7
"
W1
1
FIN.FLR.
W2
7'-0
"2"
3'-0"2" 2"
SEE SCHED.
SEE
SC
HED
ULE
2
C D
G-4
G-4
G-7
G-7
G-7
G-7
G-7
G-7DR WIDTH DR WIDTH DR WIDTH DR WIDTH
REM
OV
ABL
E M
ULLI
ON
G-4
G-4
G-4
G-4DR WIDTH DR WIDTH DR WIDTH
REM
OV
ABL
E M
ULLI
ON
3'-6
"2"
3'-0
"4"
2"
1'-6"2" 3'-0"2" 2" 11"2" 3'-0"2" 3'-0" 3'-0" 3'-0"2" 2"2" 2"10 1/4"2"
8 1/2" 10 1/4"2" 3'-0" 3'-0" 3'-0"2" 4" 2" 2"
10 1/4"2"
10 1/4"2"
2"3'
-6"
2"3'
-0"
4"
2"3'
-6"
2"3'
-0"
4"
G-4 G-4 G-4 G-4
90°
3'-6
"2"
2"3'
-4"
90°
G-4 G-4 G-4
19'-7 1/2" 5'-4 1/2" 3'-0 1/2"
3'-4 1/2"2"4 1/2"
2'-5" 2" 2" 2"2'-5" 2'-5" 2'-5"1'-4 1/4"4 1/2" 4 1/2"
SEE
SC
HED
ULE
SEE SCHED.
3'-4
"3'
-2"
6" 6"
3
4"
2'-8
1/2"
3'-0
"
2'-8 1/2"1 3/4" 1 3/4"
1 1/2
"2'
-4 3
/4"4
"
W3
4/A
2.2
3/A2.2 3/A2.2
2/A
2.2
1/A2.21/A2.25/A2.2
6/A
2.2
5/A2.2
6/A
2.2
7/A
2.2
8/A
2.2
10/A
2.2
10/A
2.2
G-7
G-7
G-4
2"
G-4G-4
2"2" 3'-4"3'-4"3'-4"
11/A2.2
NOT USED 8'-0
"
VESTIBULE101 VESTIBULE102
MTL 'J' TRIM AROUNDPERIMETER OF PANELFASTENER @ 24" O.C.
7/8" THK. PERFORATEDCORRUGATED PANELS (2)PANELS BACK TO BACK w/BRONZE FINISH EXPOSEDON VISIBLE SURFACE
7/8"
FASTENER @ 24" O.C.MTL 'J' TRIM AROUNDPERIMETER OF PANEL NEW DOOR MULLION
MTL 'J' TRIM AROUNDPERIMETER OF PANEL
DASHED LINE OFTRIM BELOW
7/8" THK. PERFORATEDCORRUGATED PANELS (2)PANELS BACK TO BACK w/BRONZE FINISH EXPOSEDON VISIBLE SURFACE
7/8"
VESTIBULE101
VESTIBULE102
7/8" THK. PERFORATED CORRUGATED PANELS(2) PANELS BACK TO BACK w/ BRONZE FINISHEXPOSED ON VISIBLE SURFACE
STICH SCREWS@ 1'-0" O.C.
1'-0
"
8'-0
"
©
DRAW
ING
INTE
NT IS
TO
IN
DICA
TE G
ENER
AL
ARRA
NGEM
ENT,
DESI
GN
AND
INTE
NT O
F W
ORK
IS P
ARTL
Y DI
AGRA
MM
ATIC
. IT S
HALL
NO
T BE
SCA
LED
FOR
ROUG
H-IN
MEA
SURE
MEN
TS
OR
SERV
E AS
ERE
CTIO
N SH
OP
DRAW
ING
S.
CONT
RACT
OR
IS
RESP
ONS
IBLE
FO
R VE
RIFIC
ATIO
N O
F DI
MEN
SIO
NS
MAR
YLAN
D.TH
E LA
WS
OF
THE
STAT
E O
F
I CER
TIFY
THAT
THE
SE
LICEN
SED
ARCH
ITECT
UND
ER
BY M
E, A
ND T
HAT
I AM
A D
ULY
DOCU
MEN
TS W
ERE
EXPI
RATIO
N DA
TE
LICEN
SE N
o.
PREP
ARED
OR
APPR
OVE
D
100
11
7.7.
20
BID DOCUMENTS
XREF
S: T
ITLEB
L
1
A2.13" = 1'-0"10
FEETSCALE3" = 1'-0"
2
A2.13/4" = 1'-0"1 0 1 2 3
FEETSCALE3/4" = 1'-0"
ALUM DOOR & FRAME
SEE
WA
LLTY
PE
SEE WALLTYPE
SEE SCHED
SEE
SC
HED
SOUND ATTENUATION
MTL STUDS
GYP. BD. (BOTH SIDES)- BOTH SIDES)
BACKER ROD & SEALNT (CONT@ PERIMETER OF FRAME
SHIM AS REQ'DALUM DOOR & FRAME
3" = 1'-0"
3
A2.2
3" = 1'-0"
4
A2.2
MTL. 'L' BEAD- CONT.@ PERIMETER OF FRAME(BOTH SIDES)
-SEE SCHED.
-SEE WALLTYPES
-SEE WALLTYPES
BLANKET
FRAME -BOTH SIDES)
BACKER ROD & SEALANT(CONT @ PERIM. OF
SOUND ATTENUATION
MTL. BOX LINTEL
GYP. BD. (BOTH SIDES)
SHIM AS REQ'D
-SEE WALLTYPES
-FILL w/ SOUND BATTS
MTL. 'L' BEAD- CONT.@ PERIMETER OF FRAME(BOTH SIDES)
MTL. STUDS @ 16" o.c.-SEE WALLTYPES
SEALANT (CONT @ PERIM.OF FRAME - BOTH SIDES)
SEALANT (CONT
JAMB ANCHORS - (3) PER SIDE
2"
SEE
SC
HED
@ PERIMETER OFFRAME - BOTH SIDES)
EXIST. 4" BRICK VENEER
3" = 1'-0"
1
A2.23" = 1'-0"
2
A2.2
DOOR-SEE SCHED.
V.I.F.
ALUM DOOR & FRAME-SEE SCHED
SEE SCHED
ALUM DOOR & FRAME-SEE SCHED
EXIST 3 5/8" MTLSTUDS @ 16" O.C.- V.I.F.
EXIST. 5/8" GYP BD.- PAINT
NEW 2x WD BLOCKINGAS REQ'D
SHIM AS REQ'DALUM. WINDOW FRAME
GLAZING
EXIST. 3 5/8" MTLSTUDS @ 16" O.C. - V.I.F.EXIST. 5/8" GYP BD.- PAINTNEW BOX BEAM LINTEL FILL w/ INSUL.SEALANT (BOTH SIDES)
ALUM. WINDOW FRAME
GLAZING
SHIM AS REQ'D
10
FEETSCALE3" = 1'-0"
7
A2.23" = 1'-0"
8
A2.23" = 1'-0"
3" = 1'-0"
5
A2.2
2"
SEE WALLTYPES
1"2"
SEE
SC
HED
SEE
WA
LLTY
PE
JAMB ANCHORS
SEE SCHED
(3 PER SIDE)SOUND ATTENUATION
MTL STUDS
GYP. BD. (BOTH SIDES)-SEE WALLTYPES
-SEE WALLTYPES
BLANKET
DOOR & FRAME-SEE SCHED
SEALANT (CONT @ PERIMETEROF FRAME - BOTH SIDES)
DOOR & FRAME-SEE SCHED
3" = 1'-0"
6
A2.2
FRAME -BOTH SIDES)
SEALANT(CONT @ PERIM. OF
SOUND ATTENUATION
MTL. BOX LINTEL
GYP. BD. (BOTH SIDES)-SEE WALLTYPES
-FILL w/ SOUND BATTS
BLANKET
3" = 1'-0"
10
A2.2
EXIST. 3 5/8" MTLSTUDS @ 16" O.C. - V.I.F.EXIST. 5/8" GYP BD.- PAINTNEW BOX BEAM LINTEL FILL w/ INSUL.
SECURE SIDE THREAT SIDE
EXIST 3 5/8" MTLSTUDS @ 16" O.C.- V.I.F.
EXIST. 5/8" GYP BD.- PAINT
NEW 2x WD BLOCKINGAS REQ'D
COUNTER BY WINDOWMANUF. - (36"x18"x1 1/2")
PASS THROUGH
WIRE PULL HANDLE
HOLE & BACKER VOICE PORT
PLUNGER LOCK & GUIDEBLOCK ASSEMBLIES
ALUMINUM BOX TRACK &VALANCE
1 3/4"x4 1/2" ALUM. TUBE
LEVEL 1 BULLETPROOFGLAZING
PORCELAIN WALLTILE TO 5'-0" A.F.F.
PORCELAIN WALLTILE TO 5'-0" A.F.F.
MTL TRIM
PORCELAIN WALLTILE TO 5'-0" A.F.F.
MTL TRIM
(E) EIFIS - V.I.F.
SHIM AS REQ'D
(E) PORCELAIN WALLTILE TO 5'-0" A.F.F.
EXIST. CONC. FLR.
CONT. BACKER ROD &SEALANT (BOTH SIDES)
ALUM. WINDOW FRAME
PERFORATED MTL PANEL
3" = 1'-0"
9
A2.2
LEVEL 1 BULLETPROOFGLAZING
SEE
WA
LLTY
PE
SEE
WA
LLTY
PE
NEW 3 5/8" MTL STUDS@ 16" O.C. - V.I.F.
EXIST. 5/8" GYP BD.- PAINT
PORCELAIN WALLTILE TO 5'-0" A.F.F.
MTL TRIM
NEW 5/8" GYP BD.- PAINT
1 3/4"x4 1/2" ALUM. TUBE
3" = 1'-0"
11
A2.2
NEW COUNTER BELOW
SECURE SIDE
THREAT SIDE
PASS THROUGH
NEW COUNTER BELOW
1 3/4"x4 1/2" ALUM. TUBENEW 3 5/8" MTL STUDS@ 16" O.C. - V.I.F.
NEW 5/8" GYP BD.- PAINTEXIST. 5/8" GYP BD.- PAINT
NEW GYP BD. - PAINT- EXTEND TO UNDERSIDEOF ROOF DECK
MTL STUDS @ 16" O.C.EXTEND STUD FRAMING TOUNDERSIDE OF ROOF DECK
MTL STUDS @ 16" O.C.EXTEND STUD FRAMING TOUNDERSIDE OF ROOF DECK
©
DRAW
ING
INTE
NT IS
TO
IN
DICA
TE G
ENER
AL
ARRA
NGEM
ENT,
DESI
GN
AND
INTE
NT O
F W
ORK
IS P
ARTL
Y DI
AGRA
MM
ATIC
. IT S
HALL
NO
T BE
SCA
LED
FOR
ROUG
H-IN
MEA
SURE
MEN
TS
OR
SERV
E AS
ERE
CTIO
N SH
OP
DRAW
ING
S.
CONT
RACT
OR
IS
RESP
ONS
IBLE
FO
R VE
RIFIC
ATIO
N O
F DI
MEN
SIO
NS
MAR
YLAN
D.TH
E LA
WS
OF
THE
STAT
E O
F
I CER
TIFY
THAT
THE
SE
LICEN
SED
ARCH
ITECT
UND
ER
BY M
E, A
ND T
HAT
I AM
A D
ULY
DOCU
MEN
TS W
ERE
EXPI
RATIO
N DA
TE
LICEN
SE N
o.
PREP
ARED
OR
APPR
OVE
D
100
11
7.7.
20
BID DOCUMENTS
XREF
S: T
ITLEB
L
W2W2
NEW PORCELAIN WALLTILE TO MATCH EXIST.
EXIST. PORCELAINWALL TILE
NEW H.M. WINDOW- SEE WINDOW TYPES
NEW GYP BD. - PAINTEXIST. GYP BD.NEW PERFORATED MTL
PANEL - SEE DTLS. 1-2/A2.1
(E)
106
NEW H.M. FRAME &RELOCATED DOOR- SEE SCHED
(E) CASEWORK RELOCATEDCASEWORK
EXIST. DOOR &FRAME TO REMAIN
105ARELOCATEDCASEWORK
NEW H.M. FRAME &RELOCATED DOOR- SEE SCHED
NEW COUNTER
VINYL BASE
RELOCATEDCLOCK
RELOCATED MAILBOXES- VERIFY DIMENSIONS IN FIELD
RELOCATEDREFRIGERATOR
EXIST. SHELF TO REMAIN
RELOCATED COPIER
EXIST. WINDOW
EXIST. WINDOW
RELOCATED CASEWORK w/ NEWCOUNTER & BACK SPLASH- COUNTER SIM TO DTL 6/A6.1
ELEVATION CELEVATION BELEVATION A
(E) PRIMEX& SHELF
RELOCATEDCASEWORK
1'-8"
INSTALL NEW COUNTER& BACK SPLASH - SIMTO DTL 6/A6.1
W2
W3
NEW H.M. WINDOW- SEE WINDOW TYPES
OPEN
EXIST. CASEWORK TOREMAIN w/ NEW COUNTERTOP - BASE BID - COUNTERSIM TO DTL 6/A6.1
OPEN 32"
42" -
V.I.F
.
1 1/2
"
42"
3 MM PVC EDGEBANDING
MIN 1/4" PREFIN.HARDBONDED BACK
MOUNTING RAILS
3/4" PARTICLE BD TOPw/ P-LAM FINISH
FIN. FLR.ELEV.
PLASTIC LAMINATE ON 3/4"MOISTURE RESISTANT PARTICLEBOARD & 3/4" BUILD-UP
1 1/2" = 1'-0"SCALE FEET1 0 1
2x WD BLOCKING
1/2" PLYWOOD SHEATHING
3/4" PARTICLE BD w/MELAMINE FINISH
6
A6.11 1/2" = 1'-0"
NEW DUPLEX RECEPTACLE
NEW DATA PORT
GROMMETED WIRE DROP
OPEN FILESFILESFILES
W3
NEW H.M. WINDOW- SEE WINDOW TYPES
6A6.1
NEW CASEWORK &COUNTER PER ADD ALT.
W2 OPEN
32"42
"
©
DRAW
ING
INTE
NT IS
TO
IN
DICA
TE G
ENER
AL
ARRA
NGEM
ENT,
DESI
GN
AND
INTE
NT O
F W
ORK
IS P
ARTL
Y DI
AGRA
MM
ATIC
. IT S
HALL
NO
T BE
SCA
LED
FOR
ROUG
H-IN
MEA
SURE
MEN
TS
OR
SERV
E AS
ERE
CTIO
N SH
OP
DRAW
ING
S.
CONT
RACT
OR
IS
RESP
ONS
IBLE
FO
R VE
RIFIC
ATIO
N O
F DI
MEN
SIO
NS
MAR
YLAN
D.TH
E LA
WS
OF
THE
STAT
E O
F
I CER
TIFY
THAT
THE
SE
LICEN
SED
ARCH
ITECT
UND
ER
BY M
E, A
ND T
HAT
I AM
A D
ULY
DOCU
MEN
TS W
ERE
EXPI
RATIO
N DA
TE
LICEN
SE N
o.
PREP
ARED
OR
APPR
OVE
D
100
11
7.7.
20
BID DOCUMENTS
XREF
S: T
ITLEB
L
2 0 2 4 6 8 101/4" = 1'-0"
SCALE FEET
1
A6.11/4" = 1'-0"
2
A6.11/4" = 1'-0"
3
A6.11/4" = 1'-0"
4
A6.11/4" = 1'-0"
CAFETERIA(E)
VAULT(E)
GENERAL OFFICE(E)
HEALTH107
VESTIBULE101
VESTIBULE101
VESTIBULE102
VESTIBULE103
LOBBY104
TEACHER LOUNGE(E)
MEN(E)WOMEN(E)
WORK / STORAGE106 PRINCIPAL105
CONF. ROOM(E)
RELOCATED EXIT SIGN
NEW EXIT SIGN
RELOCATEDLIGHT FIXTURE
RELOCATEDLIGHT FIXTURE
RELOCATEDSPEAKER
REINSTALL EXIST. SOFFIT ASREQUIRED DUE TO WORK REMOVINGAND INSTALLING NEW STOREFRONT ,& EXTENDING STUDS TO ROOF DECK
RELOCATEDLIGHT FIXTURE
EXIST. LED LIGHTFIXTURES - V.I.F.
CORRIDOR(E)
ALTERNATE AREA- SEE 2/A8.1
EXHAUST
RETURN
SUPPLY
LINEAR SUPPLY GRILL
GYP. BD. BULKHEAD
GYP. BD. CEILING
DUCT MOUNTEDSUPPLY GRILL
NEW 2' x 4' ACOUSTICALTILE AND GRID - HATCHED
FLUORESCENT RECESSEDLIGHT FIXTURE (EXISTING)
FLUORESCENT RECESSEDLIGHT FIXTURE (NEW)
12" Ø TRACK MOUNTEDPENDANT LIGHT FIXTURE
4' SURFACE MOUNTEDLIGHT FIXTURE
4' STRIP LIGHT FIXTURESUSPENDED ABOVETRANSLUCENT PANELS
DOWN LIGHT
1x2 WALL MOUNTEDLIGHT FIXTURE
EXIT SIGN - SINGLE SIDEDEXIT SIGN - DOUBLE SIDED
12" Ø DECORATIVE PENDANTLIGHT FIXTURE
SOFFIT PANELS
WALL MOUNTED LIGHT
EMERGENCY LIGHTING
(E) 2' x 4' ACOUSTICALTILE AND GRID
(E) DOWN LIGHT
4' SURFACE MOUNTEDLIGHT FIXTURE (EMERGENCY)
SPEAKERSPRINKLER HEAD (EXISTING)
LIGHT FIXTURE SCHEDULEMETALUX MODEL No.24GR-LD5-38-F1-UNV-L835-CD1-U (2x2)
WORK / STORAGE106
CONF. ROOM
STORAGE106
©
DRAW
ING
INTE
NT IS
TO
IN
DICA
TE G
ENER
AL
ARRA
NGEM
ENT,
DESI
GN
AND
INTE
NT O
F W
ORK
IS P
ARTL
Y DI
AGRA
MM
ATIC
. IT S
HALL
NO
T BE
SCA
LED
FOR
ROUG
H-IN
MEA
SURE
MEN
TS
OR
SERV
E AS
ERE
CTIO
N SH
OP
DRAW
ING
S.
CONT
RACT
OR
IS
RESP
ONS
IBLE
FO
R VE
RIFIC
ATIO
N O
F DI
MEN
SIO
NS
MAR
YLAN
D.TH
E LA
WS
OF
THE
STAT
E O
F
I CER
TIFY
THAT
THE
SE
LICEN
SED
ARCH
ITECT
UND
ER
BY M
E, A
ND T
HAT
I AM
A D
ULY
DOCU
MEN
TS W
ERE
EXPI
RATIO
N DA
TE
LICEN
SE N
o.
PREP
ARED
OR
APPR
OVE
D
100
11
7.7.
20
BID DOCUMENTS
XREF
S: T
ITLEB
L
2 0 2 4 6 8 101/4" = 1'-0"
SCALE FEET
1
A8.11/4" = 1'-0"
2
A8.11/4" = 1'-0"
KEY PLANNO SCALE
AREA OF WORK
KEY PLANNO SCALE
AREA OF WORK
WOMEN(E) MEN(E)
CAFETERIA(E)
TEACHER LOUNGE(E)
VAULT(E)
SD
D
S
D
S
D
S
SD
S D
2
2
S
1
1
1
1
1
1
2
2
3
S24
5
CONF. ROOM(E)
6
C
CORRIDOR(E)S
(E) SECURITY CAMERAMOUNTED ON BULKHEAD
D
ADA
S
T
7
CR
(E) PULL STATIONw/ STROBE ABOVE
S6
3
3
ELECTRICAL DEMOLITION NOTES
REMOVE (E) DUPLEX RECEPTACLE- PATCH ANDREPAIR ADJACENT FINISHES AS REQUIRED
REMOVE (E) DATA CONNECTION - PATCH ANDREPAIR ADJACENT FINISHES AS REQUIRED
REMOVE (E) QUAD RECEPTACLE - PATCH ANDREPAIR ADJACENT FINISHES AS REQUIRED
RELOCATE (E) SWITCH ABOVE (E) COUNTER
REMOVE & RELOCATE (E) CLOCK & ASSOCIATEDELECTRICAL CONNECTIONS
REMOVE & RELOCATE (E) SWITCH - PATCH &REPAIR ADJACENT FINISHES AS REQUIRED
REMOVE & RELOCATE (E) A-PHONE - PATCH &REPAIR ADJACENT FINISHES AS REQUIRED
1
2
3
4
5
6
7
ELECTRICAL LEGENDNEW DUPLEX RECEPTACLE, SPEC GRADE,TAMPER RESISTANT, 1PH, 125V. GROUNDINGTYPE, MTD 18" AFF UNLESS OTHERWISE NOTED
SWITCH, SPECIFICATION GRADE, SINGLE POLE15A, MOUNTED 48" AFF
S
DOUBLE SWITCH, SPEC GRADE, 15A, MOUNTED48" AFF
S2
D DATA CONNECTION
PHONE CONNECTION
C CABLE CONNECTION
GENERAL ELECTRICAL NOTES
1. GENERAL NOTES ON THIS DRAWING SHALL APPLY TO ALLELECTRICAL DRAWINGS FOR THIS PROJECT. CONTRACTOR SHALLREAD ALL GENERAL NOTES PRIOR TO BEGINNING ANY WORK
2. ANY MATERIALS AND DEVICE NOT SPECIFICALLY MENTIONED INTHE SPECIFICATIONS ORE INDICATED ON THE DRAWINGS THAT AREREQUIRED FOR A COMPLETE OPERATING SYSTEM INSTALLATIONSHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONALCOST TO THE OWNER
3. WHERE THE TERM 'PROVIDE' IS USED ON THESE DRAWINGS, ITSHALL BE DEFINED AS FOLLOWS, FURNISH, INSTALL AND MAKEALL FINAL CONNECTIONS FOR THE EQUIPMENT INDICATED
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THEEXACT ROUTING OF WIRING AND CONDUITS
5. UNLESS OTHERWISE NOTED, MOUNTING HEIGHTS FOR DEVICE ARETO TOP OF BOX
6. WHERE APPLICABLE, MOUNTING HEIGHTS SHALL CONFORM TOHANDICAP HEIGHT
7. ALL INSTALLATIONS SHALL BE INSTALLED CONCEALED, IN THEEVENT EXISTING CMU WALLS IN FINISH SPACES PROHIBITCONCEALMENT THE INSTALLATIONS SHALL BE SURFACEMOUNTED. UTILIZE SURFACE MOUNTED EMT CONDUIT WITHAPPROPRIATE SURFACE BOXES. PATCH, REPAIR AND PAINT WALLOR ADJACENT SURFACES DAMAGED WHERE EXISTING DEVICESARE REMOVED TO MATCH SURROUNDINGS
8. SEE CONTRACTOR SPECIFICATIONS FOR CUTTING AND PATCHINGREQUIREMENTS OF EXISTING WALLS AND FLOORS
9. ALL DIMENSIONS AND EXISTING CONDITIONS SHALL BE CHECKEDAND VERIFIED AT THE SITE BY THE CONTRACTOR PRIOR TO BIDS
10. WHERE EXISTING DEVICES ARE DESIGNATED TO BE REMOVED. THECONTRACTOR SHALL REMOVE THE DEVICES AND ALLASSOCIATED WIRING BACK TO THE SERVICE POINT.
11. DRAWINGS ARE DIAGRAMMATIC AND MAY NOT INDICATE ALLDEVICES AND APPURTENANCES NEEDED FOR A COMPLETESYSTEM. THE CONTRACTOR SHALL REFER TO THE SPECIFICATIONSFOR A COMPLETE DESCRIPTION OF THE SYSTEM
12. IT SHALL BE THE CONTRACTORS RESPONSIBILITY FOR REMOVINGCEILING TILE DURING THE COURSE OF WORK. UPON COMPLETIONALL CEILING TILES SHALL BE PLACED BACK WITHIN GRID SYSTEM.ANY TILES DAMAGED DURING CONSTRUCTION SHALL BEREPLACED IN KIND AT NO ADDITIONAL COST .
13. CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALLEXISTING EQUIPMENT AND UTILITIES BEFORE COMMENCING WORK
©
DRAW
ING
INTE
NT IS
TO
IN
DICA
TE G
ENER
AL
ARRA
NGEM
ENT,
DESI
GN
AND
INTE
NT O
F W
ORK
IS P
ARTL
Y DI
AGRA
MM
ATIC
. IT S
HALL
NO
T BE
SCA
LED
FOR
ROUG
H-IN
MEA
SURE
MEN
TS
OR
SERV
E AS
ERE
CTIO
N SH
OP
DRAW
ING
S.
CONT
RACT
OR
IS
RESP
ONS
IBLE
FO
R VE
RIFIC
ATIO
N O
F DI
MEN
SIO
NS
MAR
YLAN
D.TH
E LA
WS
OF
THE
STAT
E O
F
I CER
TIFY
THAT
THE
SE
LICEN
SED
ARCH
ITECT
UND
ER
BY M
E, A
ND T
HAT
I AM
A D
ULY
DOCU
MEN
TS W
ERE
EXPI
RATIO
N DA
TE
LICEN
SE N
o.
PREP
ARED
OR
APPR
OVE
D
100
11
7.7.
20
BID DOCUMENTS
XREF
S: T
ITLEB
L
2 0 2 4 6 8 101/4" = 1'-0"
SCALE FEET
1
E1.11/4" = 1'-0" KEY PLANNO SCALE
AREA OF WORK
WOMEN(E) MEN(E)
CAFETERIA(E)
TEACHER LOUNGE(E)
VAULT(E)
VESTIBULE101
VESTIBULE103
LOBBY104
PRINCIPA.L105
WORK / STORAGE106
HEALTH107
D
S
D
S
SD
S D
S
D
NEW DATA CONNECTIONSAS REQ'D FOR PRINTER
RELOCATED CLOCK &ASSOCIATED CONNECTIONS
D
NEW DATA CONNECTION
NEW DUPLEXRECEPTACLE
S2
RELOCATED DOUBLE SWITCH TOABOVE (E) COUNTER HEIGHT
CONF. ROOM(E)
S
RELOCATED SWITCH
C
GENERAL OFFICE108
CORRIDOR(E)S
(E) SECURITY CAMERAMOUNTED ON BULKHEAD
NEW 2x2 LIGHT FIXTURE-SEE CLG PLAN
NEW PHONE CNXAS REQ'D
NEW DUPLEXRECEPTACLE
(E) CLOCK
D
ADA
ADA
ADA
ADA
ADA
ADA
CR
ADA
S
RELOCATEDA-PHONE
NEW KNOXBOX
T
ADA
CR
(E) PULL STATIONw/ STROBE ABOVE
S
RELOCATED SWITCH- TIE INTO EXIST LIGHTING
3
VESTIBULE102
3
3
TIE INTO EXIST LIGHTS IN108 GENERAL OFFICE
S2
RELOCATED SWITCH- TIE INTO EXIST LIGHTING
3
ELECTRICAL LEGENDNEW DUPLEX RECEPTACLE, SPEC GRADE,TAMPER RESISTANT, 1PH, 125V. GROUNDINGTYPE, MTD 18" AFF UNLESS OTHERWISE NOTED
SWITCH, SPECIFICATION GRADE, SINGLE POLE15A, MOUNTED 48" AFF
S
DOUBLE SWITCH, SPEC GRADE, 15A, MOUNTED48" AFF
S2
D DATA CONNECTION
PHONE CONNECTION
C CABLE CONNECTION
GENERAL ELECTRICAL NOTES
1. GENERAL NOTES ON THIS DRAWING SHALL APPLY TO ALLELECTRICAL DRAWINGS FOR THIS PROJECT. CONTRACTOR SHALLREAD ALL GENERAL NOTES PRIOR TO BEGINNING ANY WORK
2. ANY MATERIALS AND DEVICE NOT SPECIFICALLY MENTIONED INTHE SPECIFICATIONS ORE INDICATED ON THE DRAWINGS THAT AREREQUIRED FOR A COMPLETE OPERATING SYSTEM INSTALLATIONSHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONALCOST TO THE OWNER
3. WHERE THE TERM 'PROVIDE' IS USED ON THESE DRAWINGS, ITSHALL BE DEFINED AS FOLLOWS, FURNISH, INSTALL AND MAKEALL FINAL CONNECTIONS FOR THE EQUIPMENT INDICATED
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THEEXACT ROUTING OF WIRING AND CONDUITS
5. UNLESS OTHERWISE NOTED, MOUNTING HEIGHTS FOR DEVICE ARETO TOP OF BOX
6. WHERE APPLICABLE, MOUNTING HEIGHTS SHALL CONFORM TOHANDICAP HEIGHT
7. ALL INSTALLATIONS SHALL BE INSTALLED CONCEALED, IN THEEVENT EXISTING CMU WALLS IN FINISH SPACES PROHIBITCONCEALMENT THE INSTALLATIONS SHALL BE SURFACEMOUNTED. UTILIZE SURFACE MOUNTED EMT CONDUIT WITHAPPROPRIATE SURFACE BOXES. PATCH, REPAIR AND PAINT WALLOR ADJACENT SURFACES DAMAGED WHERE EXISTING DEVICESARE REMOVED TO MATCH SURROUNDINGS
8. SEE CONTRACTOR SPECIFICATIONS FOR CUTTING AND PATCHINGREQUIREMENTS OF EXISTING WALLS AND FLOORS
9. ALL DIMENSIONS AND EXISTING CONDITIONS SHALL BE CHECKEDAND VERIFIED AT THE SITE BY THE CONTRACTOR PRIOR TO BIDS
10. WHERE EXISTING DEVICES ARE DESIGNATED TO BE REMOVED. THECONTRACTOR SHALL REMOVE THE DEVICES AND ALLASSOCIATED WIRING BACK TO THE SERVICE POINT.
11. DRAWINGS ARE DIAGRAMMATIC AND MAY NOT INDICATE ALLDEVICES AND APPURTENANCES NEEDED FOR A COMPLETESYSTEM. THE CONTRACTOR SHALL REFER TO THE SPECIFICATIONSFOR A COMPLETE DESCRIPTION OF THE SYSTEM
12. IT SHALL BE THE CONTRACTORS RESPONSIBILITY FOR REMOVINGCEILING TILE DURING THE COURSE OF WORK. UPON COMPLETIONALL CEILING TILES SHALL BE PLACED BACK WITHIN GRID SYSTEM.ANY TILES DAMAGED DURING CONSTRUCTION SHALL BEREPLACED IN KIND AT NO ADDITIONAL COST .
13. CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALLEXISTING EQUIPMENT AND UTILITIES BEFORE COMMENCING WORK
ELECTRICAL REQUIREMENTS FOR MECHANICAL EQUIPMENT
1. ALL CONTROL WIRING (LINE VOLTAGE AND OR LOW VOLTAGE) FOR MECHANICALEQUIPMENT PROVIDED UNDER DIVISION 23, SHALL BE FURNISHED AND INSTALLED UNDERDIVISION 23. WIRING FROM POWER SOURCE TO ALL CONTROL PANELS, DDC CONTROLPANELS, STARTERS, OPERATOR WORK STATIONS (PC'S, PRINTERS, MONITORS, ANDOTHER WORK STATION EQUIPMENT) AND OTHER CONTROL EQUIPMENT REQUIRED FOR ACOMPLETE AND OPERABLE CONTROL SYSTEM SERVING MECHANICAL EQUIPMENTPROVIDED UNDER DIVISION 23, SHALL BE FURNISHED AND INSTALLED UNDER DIVISION 23
2. ALL WIRING FROM CONTROL PANELS TO CONTROL DEVICES FOR MECHANICALEQUIPMENT PROVIDED UNDER DIVISION 23 SHALL BE FURNISHED AND INSTALLED UNDERDIVISION 23. ALL CONTROL WIRE AND CONDUIT SHALL COMPLY WITH THE NATIONALELECTRIC CODE AND DIVISION 26 OF THE SPECIFICATIONS. ALL CONTROL WIRING SHALLBE IN CONDUIT.
3. UNLESS OTHERWISE NOTED. ALL TEMPERATURE CONTROL DEVICES, INSTALLED PILOTDEVICES, AND ALL ASSOCIATED PILOT CONTROL EQUIPMENT, FOR ALL EQUIPMENTPROVIDED UNDER DIVISION 23, SHALL BE FURNISHED AND INSTALLED UNDER DIVISION 23
4. ELECTRICAL CONTROL WIRING FOR CONNECTION OF TEMPERATURE CONTROLLERS, PUSHBUTTONS, INTERLOCKS IN MOTORE CONTROLLERS, PNEUMATIC SWITCHES AND LIKEITEMS IS SPECIFIED UNDER THE CONTROL SECTIONS IN DIVISION 23 AND INSTALLEDUNDER DIVISION 23
STOR.109
SNEW SWITCH
TIE INTO EXIST LIGHTS IN108 GENERAL OFFICE
3S3
©
DRAW
ING
INTE
NT IS
TO
IN
DICA
TE G
ENER
AL
ARRA
NGEM
ENT,
DESI
GN
AND
INTE
NT O
F W
ORK
IS P
ARTL
Y DI
AGRA
MM
ATIC
. IT S
HALL
NO
T BE
SCA
LED
FOR
ROUG
H-IN
MEA
SURE
MEN
TS
OR
SERV
E AS
ERE
CTIO
N SH
OP
DRAW
ING
S.
CONT
RACT
OR
IS
RESP
ONS
IBLE
FO
R VE
RIFIC
ATIO
N O
F DI
MEN
SIO
NS
MAR
YLAN
D.TH
E LA
WS
OF
THE
STAT
E O
F
I CER
TIFY
THAT
THE
SE
LICEN
SED
ARCH
ITECT
UND
ER
BY M
E, A
ND T
HAT
I AM
A D
ULY
DOCU
MEN
TS W
ERE
EXPI
RATIO
N DA
TE
LICEN
SE N
o.
PREP
ARED
OR
APPR
OVE
D
100
11
7.7.
20
BID DOCUMENTS
XREF
S: T
ITLEB
L
2 0 2 4 6 8 101/4" = 1'-0"
SCALE FEET
1
E1.21/4" = 1'-0" KEY PLANNO SCALE
AREA OF WORK
2
E1.21/4" = 1'-0"